HomeMy WebLinkAboutCO'S & DOCS - 01-00036 - Parkside Townhomes - Bldg 4 units 14-18CERTIFICATE OF OCCUPANCY City of Rexburg Department of Building Inspection Building Permit No: R- o1-10 -o2 Applicable edition of code: ❑ International Building Code 2000 if International Residential Code 2000 ❑ Uniform Building Code 1997 Site address: 864 Georgetown Square North Use and occupancy: Residential Townhome Type of construction: Wood Frame Design occupant load: Family Unit Sprinkler System required: ❑ Yes ONo Name and address of owner: Georgetown De 223o North Un Provo, Utah 84 Contractor: Georgetown Development Special conditions: Occupancy: ,' Full ❑ Partial ❑ Temporary This Certificate, issued pursuant to the requirements of Section RN of the International Building Code, certifies that, at the time of issuance, this building or that portion of the building that was inspected on the 'bate fisted was f ouna to be in compliance with the requirements of the co'be for the group an() ()ivision of occupancN an() the use for which the propose() occupancN was cfassi f ie(). Date: December 4, 2003 (2:41PM) C.O. Issued b y: e&;( Building Official There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Buildin: . ci has reviewed and approved said future changes. Water Department '. .- ..f.�' . Fire Department Nfk // State of Idaho Electrical Department - ( 356 -4830) ❑ Merlin Webster ,g6c _1-6e/r/7 CERTIFICATE OF OCCUPANCY City of Rexburg Department of Building Inspection Building Permit No: R- o1-10 -o2 Applicable edition of code: ❑ International Building Code 2000 ❑ International Residential Code 2000 ❑ Uniform Building Code 1 997 Site address: 868 Georgetown Square North Use and occupancy: Residential Townhome Type of construction: Wood Frame Design occupant load: Family Unit Sprinkler System required: ❑ Yes ❑ No Name and address of owner: Georgetown Development 2230 North University Pkwy., Suite 7G Provo, Utah 84604 Contractor: Georgetown Development Special conditions: Occupancy: ❑ Full This Certificate, issued pursuant to the requirements of Section 109 o tbe International Building Code certifies that, at the time of issuance, this building or at portion of tbe building that was inspected on the date listed was found to be in compliance with the requirements of the code for tbe group and division of occupancj and tbe use for which tbe proposed occupancN was classified. Date: December 4, 2003 (2:42PM) C.O. Issued by: Building Official There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Buitdin 0ffy jial has rev iewed and approved said future changes. Water Department/ 4i e e c _Fire Department State of Idaho Electrical Department - (208 -356 -4830) ❑ Merlin Webster ❑ Partial ❑ Temporary g6ei . LPL CERTIFICATE OF OCCUPANCY City of Rexburg Department of Building Inspection Building Permit No: R- o1-lo -o2 Applicable edition of code: ❑ International Building Code 2000 ❑ International Residential Code 2000 ❑ Uniform Building Code 1 997 lsz Site address: Use and occupancy: Residential Townhome Type of construction: Wood Frame Design occupant load: Family Unit Sprinkler System required: ❑ Yes ❑ No Name and address of owner: Georgetown Development 223o North University Pkwy., Suite 7G Provo, Utah 84604 Occupancy: ❑ Full Date: December 4, 2003 (2:41PM) Contractor: Georgetown Development Special conditions: ❑ Partial ❑ Temporary This Certificate, issue() pursuant to the requirements of Section io9 o tbe International Buil ()ing Cok certifies that, at the time of issuance, this buillin9 or at portion of the building that was inspecte() on the ()ate liste() was f oun() to be in compliance with the requirements of the co()e for the group an ()ivision of occupancy an the use for which tbe propose() occupancy was classi f ie(). C.O. Issued by: Building Official There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Building,)ffici.. has revie ed and approved said future changes. Water Department , , Fire Department /VA State of Idaho Electrical Department - ( - 356-4830) ❑ Merlin Webster CERTIFICATE OF OCCUPANCY City of Rexburg Department of Building Inspection Building Permit No: R- o1 -10 -02 Applicable edition of code: ❑ International Building Code 2000 International Residential Code 2000 ❑ Uniform Building Code 1 997 Site address: 86o Georgetown Square T Use and occupancy: Residential Townhome Type of construction: Wood Frame Design occupant load: Family Unit Sprinkler System required: ❑ Yes ,17 Name and address of owner: Georgetown D 223o North U: Provo, Utah 84fuu Contractor: Georgetown Development Special conditions: Occupancy: Full This Certificate, issue') pursuant to the requirements of Section 109 of the International Bui(')ing Code, certifies that, at the time of issuance, this building or that portion of the building that was inspect@ on the bate list@ was f ouna to be in compliance with the requirements of the code for the group and division of occupancN an') the use for which the propos@ occupancN was c(a.ssi f ied. Date: December 4, 2003 (2 :41PM) C.O. Issued by: ❑ Partial ❑ Temporary Be Building Official There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Buil " pffici as revi wed d approved said future changes. Water Department ' ' s ; _ �, �, e Department � artment p State of Idaho Electrical Department - (208 -356 -4830) 0 Merlin Webste CERTIFICATE OF OCCUPANCY City of Rexburg Department of Building Inspection Building Permit No: R- o1-lo -o2 Applicable edition of code: ❑ International Building Code 2000 ❑ International Residential Code 2000 ❑ Uniform Building Code 1997 Site address: 862 Georgetown Square North Use and occupancy: Residential Townhome Type of construction: Wood Frame Design occupant load: Family Unit Sprinkler System required: ❑ Yes ❑ No Name and address of owner: Georgetown Develop] 223o North Universit Provo, Utah 84604 Contractor: Georgetown Development Special conditions: Occupancy: ❑ Full This Certificate, issued pursuant to the requirements of Section 109 of the International Building Cooe, certifies that, at the time of issuance, this building or at portion of the building that was inspected on the bate listed was f ouna to be in compliance with the requirements of the cone for the group and division of occupancN and the use for which the proposed occupancN was classif iea. Date: December 4, 2003 (2:41 C.O. Issued by: ❑ Partial ❑ Temporary 865 - Building Official There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Building Offici.1 has re 'ewed and approved said future changes. Water Department - . Fire Department State of Idaho Electrical Department - (208 -356 -4830) ❑ Merlin Webster CITY OF REXBURG AMERICAS FAMILY COMMUNITY 19 E. Main (PO Box 280) Rexburg, Idaho 83440 www.rexburq.orq CERTIFICATE OF OCCUPANCY Department of Building Inspection Building Permit No: R- o1-10 -o2 Applicable edition of code: ❑ International Building Code 2000 ❑ International Residential Code 2000 ❑ Uniform Building Code 1 997 �i9g S one k 774. rii�n� '70.re-a 61 feral Site address: Use and occupancy: Type of construction: Design occupant load: Sprinkler System required: Name and address of owner: Special conditions: Occupancy: JFull ❑ Partial ❑ This Certificate, issued pursuant to the requirements of Section 3.09 of the International Building Code, certifies that, at the time of issuance, this building or that portion of the building that was inspected on the date listed was found to be in compliance with the requirements of the code for the group and division of occupancy and the use for which the proposed occupancy was classified. C.O. Issued by: Water Departm NITY DEVELOP DEPARTMENT Parkside Twinhomes 862 Georgetown Sq. N Residential Twin Homes Wood Frame Residential Units ❑ Yes ia Georgetown DE 223o N. Univei Provo, Ut. 846( n Date: 7* 28 Phone: 208 - 359 -3020 x326 Fax: 208- 359 -3024 cathyw@ci.rexburg.id.us e63 . - re - ,wh ko rke-S Building Official There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Building Official as reviewed and approved said future changes. ■ Fire Department NA State of Idaho E ectrical Depa ent - (208 - 356-4830) ❑ Merlin Webster REMARKS: VALUE FEE PAID BUILDING INSPECTOR DEPARTMENT OF BUILDING & ZONING DATE ADDRESS WHITE— Owners Copy CANARY — Building Department's Copy PINK — Assessor's Copy GOLDENROD- Inspector BUILDING PERMIT APPLICATION REXBURG, ID DATE 0 NO.. THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNERL-.1 j ,. ' , . .?.: BUILDER STRUCTURE: RESIDENCE FOOTINGS CONCRETE 0 MASONRY 0 OTHER T JOB ADDRESS? " ARCHITECT CI REMODEL 0 ADDITION CI EDUCATIONAL 0 GOVT 0 RELIGIOUS ,:; ,/, 17 7 PHONE 1C4 ;: h ‘*' 4/1 NEW COMM. FOUNDATION QtONCRETE 0 MASONRY p OTHER BASEMENT 1010AFMAL CI FULL 0 NO FLOORS WOOD la CONCRETE D OTHER EXT. WALLS INT. WALLS WOOD MASONRY O CONCRETE 0 VENEER p METAL 0 STUCCO IOIWOOD MASONRY QQ,.� (' DRYWALL 0 PLASTER p TILE p REPAIR O FENCE O PATIO CEILING WOOD DRYWALL PLASTER 0 TILE O ACOUSTIC 0 OPEN 0 RENEWAL 0 FIR 0 CARPORT 0 GARAGE ROOF [� BUILT UP. 4 WOOD SH. COMP. SH. 0 TILE ❑ ROLL ROOF. p METAL HEAT I/GAS ❑ ❑ OIL p COAL 0 FIREPLACE 0 ELECTRIC DESIGNER E DAMAGE 0 AWNING INSULATED WALLS F� CEILING LL.00RS 6TPERIMETER This permit is issued subject to the regulations contained in the Uniform Building Code and Zoning Regulations of Rexburg, and it is herAkagreetiii that the work to be done as shown in the plans and spec'if'ication will be completed in accordance with the pertaining and applicable thereto: The issuance of the permit does not waive restrictive covena ts. Date of Application SEPTr. 25", 200 1 OWNER Name GEORWCWAI 0 EvLGOPME.iI T Site Address Mailing Address 2230 N • U/ zuLest Y SUxrf 7 07 City /State/Zip PROVO, (Jr Sy Lo AAx rµocsrl,E, Telephone/Fax/Mobile sot-TN-011T 1 901 -375- O6&2 / 2Os- 6519-32p,‘ / 2c +, -361- 5389 CONTRACTOR Name GEOfZ6F_T6W N OEuELoPf kENT Mailing Address 2230 N. (J,. wE2Strt AAcW»_ SULTE 7G City /State /Zip Pgovo, Ur 8 FR =moo FAX j /1•aaz+x Telephone Fax/Mobile 661- 374- 0"1/2 /�i - 3'15 -0502 / 20A- (d56- 3'1 81 Plot - 351 -53G9 PROJECT INFORMATION DEPARTMENT APPROVAL Property Zone: Is existing use compatible with zoning, (screening parking, etc) When was this building last occupied NEW l oLUOING Architect/ Engineer Firm Tcu N Plan Name PARKSC >E Tr H -tags APPLICATION FOR BUILDING PERMIT CITY OF REXBURG, IDAHO Subdivision Circle One • esidentia ommercial Educational Government Remodel Other Circle One �ew Hou Addition/Remodel to House New Commercial Commercial Remodel Circle One Basement: ►l Finished / Unfinished Other: None/ Patio/ Carport/ Awning N/A Lot Square Footage Lot Width Square Feet Garage Square Feet Number of Stories 2 Height of Building What will structure be used for: om- Home Business Apartment Commercial Other 1 Will there be an apartment? NO If so, how many units Total Estimated Cost 9 272 r 000_ Are you in a flood plain OCT 0 D 2001 Permit No. /h A - UNw , 6- un+c.r PAak.sroe. / Pcarsom eilecusev Lot A mg-1 Block ButtL1I246 q Lscris 1y -1 8 F REXBURG Signature of Applicant Code Building Permit Fees / 5i) , y Jr Zone Plan Check Fees /V51 7e' Building Type Pluming Permit Fees 0010 ®© Digging Permit Fees Water & Sewer Fees 1,1?) J c -I TOTAL $ /,, g ®• 6 6 Signature of Inspector Issued by Rough Plumbing Septic Tank Fixtures Water Piping Complete Sewer 5 Bath Tubs Urinal Showers Sink Trap Laundry Trays Water Heater 5 Wash Basin / . Other Toilet t L+ Slop Sinks Kitchen Sinks 5 Floor Drain 5 Drinking Fountains Lawn Sprinklers Water Softeners Dish Washing Mach. 5 Clothes Washer Name L Address Lot r `ft OWNER l "t1)1 Blk. �' y 1 T eI. 14 7'/. '? Add. , . - PLUMBER Name 'n7 fir° / 'rrM Address � Tel. • ' 1 / °' S ^ NATURE OF INSTALLATION Use DESCRIPTION OF WORK CITY OF REXBURG APPLICATION FOR PLUMBING PERMIT Plumbing Permit Sewer Inspection Inspection of Pipe Inspection of Fixtures Received: Date By Plumbing Sewer Other Finish Plumbing G - 7;35TAL _A 9- > / s INSPECTOR'S RECORD N OCT 0 2001 CITY OF REXBURG INSP. NAME E +; xoavatica St Zart`awcr.k: Concrete: Roofing: Insulation: Zbusq..lEaS EOEU'r1 E4 E2. Q SON S Masonry : S& UZQ.E 3Ak62 kccriver tab& :�NS U LJ rzoN Drywall: 5422`1 7(2 f cu t.L Painting: Floor Ccverincs : P l urnb ing : SUBCONTRACTOR MET PAINT IN(' 5140WCASE 1 S1 vL N£wrtw f Uitino Heating CON AN (E31' -ENT) Electrical: LELE',N+h14N EiE -nux.. Roof Trusses: Floor / Ceiling Joists: SPECIAL CONSTRUCTION (MANUFACTURER OR SUPPLIER) 13rY1 C t.c sr Bine. Esr Cabine is : A SESTTL C,A4rNE73 l r r s 1 Sidimc Exterior Trim: T N - EXTEaLicAS Cther : PU41413 Vi Cr RESIDENTIAL PLAN CHECKLIST 1998 INTERNATIONAL ONE AND TWO FAMILY DWELLING CODE Building Permit Number Project: 6eoeoc-row.J Cpr\iNe Job Address: I So(D u i ,. j -2.)0 Zoning: Lt, IZ -r l �� Number of Stories: 2. Floor Area: ok -N sCx 2. = 209 6 2. � C. Description: \ ©uo,‘ 1�usu Valuation: Permit Fee: Plan Check Fee: The following comments based on the 1998 edition of the International One and Two Family Dwelling Code should be resolved before a building permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International One and Two Family Dwelling Code or any federal, state or local regulations. 1. PLAN CHECK A. Plans .� To Scale Legible "Plot Plan VF1oor Plan Section showing construction details A1l Building Elevations NA Flood Plain (when necessary floor and grade elev. should be shown Design Criteria (Design Criteria shall be identified on plans as Wind Snow — 35 lb. per sq. ft.) B. Zoning (check one — in some cases LDR2 and MDR may apply) NR LDR LDR1/ /111)12 C. Use Single Family 771 OA Duplex (LDR1 only) D. Lot Area (LDR2 & MDR not covered) Lot area (LDR 12,000 sq. ft. min. & LDR1 8,000 sq. ft. min.) E. Lot Minimum Width (LDR2 & MDR not covered) Lot Width (LDR 80 ft. min. & LDR1 60 ft. min.) on the plans) — 80 m.p.h., 2 F. Set Backs (taken from eaves) Front set back (25 ft.) TRear set back (LDR 25 ft. & LDR1 20 ft.) Sides set backs (6" for every ft. of building height with LDR 7.5' min. & LDR1 6' min.) G. Building Height 'Building_Height (maximum 30 ft.) H. Footings Proper Size (as per Table 403.1.1, use 1500 psf unless exact soil type is known, then use Table 401.4.1 to determine soil bearing) 7 Rebar (244 min., to be tied in place or supported with approved chairs or dobies) __ pi y Girder Support Footings (size as per Table 502.3.4(2) ✓Footing Depth (36" below finished grade) Fireplace Footings (12" thick min. & must extend past foundation 6") 1. Foundation Foundation walls (shall be designed as per Section 404.1.4 & Table 404.1.1(2)) ±Foundation Drainage (foundations on silt soil shall be designed per Section 405.1) �l1 Waterproofing (as per section 406) ✓ Crawl Space Ventilation (1 sq. ft. per 1500 sq. ft. of crawl space when moisture barrier otherwise 1 sq. ft. per 150 sq. 1 vent must be within 3' of each building comer — one side of building not required to have vents) ✓Crawl Space Moisture Barrier Grading (all yards shall slope away from house) / Window Wells (clear horizontal; dimensions parallel to foundation wall shall be at least as wide as the window and wider if needed to fully open the window and the perpendicular dimension from window to window well is 24" min.) Q�. Concrete Floors (shall be 31/2" thick 2500 p.s.i. concrete on minimum 4" gravel base) J. Frame .Floors (check load bearing capacity of joists as per Section 502) .- Under Load Bearing Partitions (shall be doubled as per Section 502.3.3) 1 Header Joists (shall be doubled if over 4') Opening Multiple Joists (joists which carry headers shall be doubled or tripled etc. to make up for the amount of joists carried by the header) Girders (shall be designed as per Table 502.3.4(1)) Floor Sheathing (check joist span as per Tables 503.1, 503.2.1.1(1) & 503.2.1.1(2)) ±Exterior Wail (design as per tables 602.3.2(1), 602.3.2(2) & 602.3.2(3)) Load Bearing Walls (design as per Section 602.3.2) t Wall Window and Door Headers (design as per Tables 602.7 & 602.7.2) Fire Blocking (as per Section 602.8) . Nit Wall Bracing (as per Section 602.10) N4 Rafters (check load bearing capacity of rafters as per Section 802.4.3) df Ceiling Joists (check load bearing capacity as per Section 802.4.2) ±Roof Trusses (designed according to Section 802.9 and braced as per manufacturer) 3 N. Firewalis '4 Garage (a one -hour fire - resistive separation provided between garage &. e 4 r7 Rafter and Truss Tie -Downs (shall be designed according to Section 802.10) LRoof Sheathing (as per Section 803) Qd car ✓ Attic Access (provide 22" x 30" min. access where attic dear height exceeds 30 ") K. Exterior Covering ✓Siding (as per Table 703.4) , Brick or Stone Veneer (as per Table 703.4, note that sheathing paper is required with spacing of 1" or solid filled mortar) L. Roof Covering and Ventilation . Ventilation (as per Section 806) , Asphalt Shingles (as per Table 903.1) N Slate Shingles (as per Section 904) Metal (as per Section 905) Clay, Tile or Concrete Shingles (as per Section 906) 44 Wood Shingles (as per Section 908) lVfr Wood Shakes (as per Section 909) M. Fireplaces ` Masonry Fireplace (design and reinforcement as per Section 1003) /A- Chimney Termination (chimneys shall extend a minimum of 2' higher than any portion of the building within 10', but shall not be less than 3' above roof. 5 l b Door from Garage to House (1 3 /4" solid wood, exterior metal or 20 min. rated fire door required) Two Family Dwelling Separation (1 hr. firewall & see Section 320.2.2) 0. General Requirements Light and Ventilation (design as per Section 303) Minimum Room Areas (every dwelling shall have one room at least 150 sq. ft., other habitable rooms shall have min. area of 70 sq. ft, min. kitchen size is 50 sq. ft. and habitable rooms except kitchens shall have min. dimension of 7 ft) `` Minimum Ceiling Height (as per section 305) 14A Windows at Hazardous Locations identified by Section 308.4 with requirements Y uirements q listed in Section 308.3)) Window Egress Exit Door (one exit door must be 36" wide) Landings (a min. 3' x 3' landing required at each side of egress doors with thresholds not more than 1 1/2" higher than landing) Stair Rise and Run (7 3 /4" max. riser & 10" min. tread) Stairway Width (36" min. disregarding handrails) Stairway Headroom (6' 8" min.) `Stairway Protection (enclosed accessible space under stairs covered with 1 /2" drywall) addo Handrails (34" min. & 38" max. from stair tread nosing) Guardrails (36" height, mandatory at 30" drop and 4" sphere must not pass through) 6 Smoke Detectors (each bedroom and one on each level) +/Mechanical Ventilating Systems (in bathrooms, laundry rooms and similar rooms should provide five air changes per hour directly to the outside with the point of discharge of exhaust air at least 3 feet (914 mm) from any opening that allows air entry into occupied portions of the building) Kitchen (every dwelling unit should be provided with a kitchen equipped with a kitchen sink) `Bathroom (dwelling units should be provided with a bathroom equipped with facilities consisting of a water closet, lavatory and either a bathtub or shower) I gn Des ntelligence, LLC Structural Engineering 135 East Main, Suite A Rexburg, Idaho 83440 Date: August 27, 2001 To: Jon Berry City of Rexburg, Plan Reviewer Call: (208) 359 -1461 FAX: (208) 359 -0740 Subject: Parkside Planned Residential Development — Townhouse Drawing Comments Dear Mr. Berry, The following responses to your comments are offered for your review and approval. Comment #1 — Upper balcony units do not have details showing the cantilever details for the 2x8 floor joists. Will the joists span the extra space. Resolution: There is a balcony on some units as shown on the elevation drawings. These balconies extend 4' -6" out from the face of the building. The 2x8 joists extend back into the building more than twice that distance. This assures that the cantilever joists are sufficiently supported for uplift and the joists are not over stressed at the cantilever. Comment #2 — The Shear walls are shown as 2 different types on the plans ( #1 and #7) but the specifications only have one specified. Is there a difference as shown on the plans or are they both considered the same as the specs? Resolution: There is only one type of shear wall. The numbers will be stricken from the drawings. Comment #3 — Simpson PAHD -42 hold -downs are specified on the plans but are also "optional see engineering ". There is no mention of these in the calculations. Are these to be used or not? Resolution: Yes, these hold downs are to be used. The drawings show PAHO -42. This should be PAHD -42. Optional has been stricken from the drawings. Comment #4 — There is a question of support under the MB4b beam of the "A" unit at the end by the stair and also the MB3 beam of the "B" unit at the same end. Can the beam (BB1) under the main floor support the load of the 1 and 2nd floors at approximately 3 and 6 feet from the wall? 1 Resolution: Yes — see attached additional calculations. Please call if you have any questions. ,( Scott A Spaulding, P.E. Design Intelligence, LL 2 Dear Sir; STATE OF IDAHO www.ci.rexburg.id.us Thank you for any assistance you might be able to give. //// P.O. Box 280 U 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359 -3020 Fax (208) 359 -3022 e -mail rexburg @ci.rexburg.id.us 16 Aug 2001 The following items are missing from your permit package and are required for me to complete your Plans Review. Any help in getting these items would be greatly appreciated and speed the process. Please get these resolved as soon as possible. 1. Upper balcony units do not have details showing the cantilever details for the 2" x 8" floor joists. Will the joists span the extra space? 2. The Shear walls are shown as 2 different types on the plans #1 and #7 but the specifications only have 1 specified. Is there a difference as shown on the plans or are they both considered the same as in the specs? 3. Simpson PAHO -42 hold -downs are specified on the plans but are also "optional see engineering ". There is no mention of these in the calculations. Are these to be used or not? 4. There is a question of support under the MB4b beam of the "A" unit at the end by the stairs and also the MB3 beam of the `B" unit at the same end. Can the beam (BB 1) under the main floor support the load of the 1 and 2n floors at approximately 3 and 6 feet from the foundation wall? Sincerely, Jon Berry City Building Inspector • Date:. Building Permit Number: Project: I-; (de. - r.74- Job Address: Sip& w. (er ,9G FINAL INSPECTION CHECKLIST The following comments based on the 1998 edition of the International One and Two Family Dwelling Code should be resolved before an occupancy permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International One and Two Family Dwelling Code or any federal, state or local regulation. Strop LL" +� Fire- exu4 k reite h (e4 f s k to M O UTSIDE /House Numbers /Grade (yard is sloped away from foundation) Sidewalk & Landscape Strip 5' wide (W/ 6" of granular borrow (hill 12 ")) - -7' LS strip Front Setback Coverage 70% min green , Windows - Covers and Screens (shall be releasable or removable from the inside for egress Window Wells min. 24" clear (out and above) well Exterior Steps (7 3/4 " max. rise & 10" min. tread) /Stairway Handrails 3 or more risers or over 30" ( <4" max. spacing of uprights) Guardrails (provide if over 30" above floor /grade & 4" max sphere spacing for uprights) /Landings (36" x 36" min., (not req. at the top of the stair if a door does not swing over stairs) .1 Thresholds 1 1/2" max. above floor or landing (7 3/4" max if door does not swing over landing) /Posts (required to be treated, redwood or cedar if in contact of concrete / earth) Roofing (no apparent leaks, installed properly and roofing as per plans) ,Masonry (lintels as per table 703.7. 1) /Roof Ventilation (as per plans) Chimney, Crickets, (30" or wider parallel to ridge) Height (3' min above the roof and 2'min. above any portion within 10' INSIDE /gress Doors (all egress doors must be able to open from inside without use of keys or tools) /Safety Glazing provided in all doors, within 24" of door arc and below 60 ", anyplace when panel is over 9 sq. ft. and bottom edge less than 18" and top edge greater than 36" above floor) Fireplaces & Hearth Extensions masonry (built as per plans) /Bathroom Ventilation (either operable window or fan that vents directly to outside) inks, Bathtubs and Showers (check for caulking, operation and Teaks) tairway Illumination (switch at top and bottom) FINAL INSPECTION CHECKLIST Date: Z _ Building Permit Number: le-of - /0 -07_ Project: par Ks l }-L Job Address: 0(00 G ear ildaurn. N6r The following comments based on the 1998 edition of the International One and Two Family Dwelling Code should be resolved before an occupancy permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International One and Two Family Dwelling Code or any federal, state or local regulation. b OUTSIDE House Numbers /Grade (yard is sloped away from foundation) 4idewalk & Landscape Strip 5' wide (W/ 6" of granular borrow (hill 12 ")) - -7' LS strip /Front Setback Coverage 70% min green / Windows - Covers and Screens (shall be releasable or removable from the inside for egress X Window Wells min. 24" clear (out and above) well /Exterior Steps (7 3/4 " max. rise & 10" min. tread) l Stairway Handrails 3 or more risers or over 30" ( <4" max. spacing of uprights) /Guardrails (provide if over 30" above floor /grade & 4" max sphere spacing for uprights) /Landings (36" x 36" min., (not req. at the top of the stair if a door does not swing over stairs) / hresh°Ids 1 1/2" max. above floor or landing (7 3/4" max if door does not swing over landing) /Posts (required to be treated, redwood or cedar if in contact of concrete / earth) /Roofing (no apparent leaks, installed properly and roofing as per plans) Masonry (lintels as per table 703.7. 1) /Roof Ventilation (as per plans) Chimney, Crickets, (30" or wider parallel to ridge) Height (3' min above the roof and 2'min. above any portion within 10' INSIDE < Egress Doors (all egress doors must be able to open from inside without use of keys or tools) /Safety Glazing provided in all doors, within 24" of door arc and below 60 ", anyplace when panel is over 9 sq. ft. and bottom edge Tess than 18" and top edge greater than 36" above floor) Z Fireplaces & Hearth Extensions masonry (built as per plans) Bathroom Ventilation (either operable window or fan that vents directly to outside) . l S inks, Bathtubs and Showers (check for caulking, operation and leaks) %tairway Illumination (switch at top and bottom) Date: Building Permit Number: Project: gc/ Job Address: FINAL INSPECTION CHECKLIST r €um ware- The following comments based on the 1998 edition of the International One and Two Family Dwelling Code should be resolved before an occupancy permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International One and Two Family Dwelling Code or any federal, state or local regulation. OUTSIDE /House Numbers Grade (yard is sloped away from foundation) %idewalk & Landscape Strip 5' wide (W/ 6" of granular borrow (hill 12")) - -7' LS strip 4 ront Setback Coverage 70% min green Windows - Covers and Screens (shall be releasable or removable from the inside for egress Z Window Wells min. 24" clear (out and above) well /Exterior Steps (7 3/4 " max. rise & 10" min. tread) ›Stairway Handrails 3 or more risers or over 30" ( <4" max. spacing of uprights) Guardrails (provide if over 30" above floor /grade & 4" max sphere spacing for uprights) Landings (36" x 36" min., (not req. at the top of the stair if a door does not swing over stairs) Thresholds 1 1/2" max. above floor or landing (7 3/4" max if door does not swing over landing) {osts (required to be treated, redwood or cedar if in contact of concrete / earth) Roofing (no apparent leaks, installed properly and roofing as per plans) Masonry (lintels as per table 703.7. 1) Roof Ventilation (as per plans) Chimney, Crickets, (30" or wider parallel to ridge) Height (3' min above the roof and 2'min. above any portion within 10' INSIDE E gress Doors (all egress doors must be able to open from inside without use of keys or tools) /afety Glazing provided in all doors, within 24" of door arc and below 60 ", anyplace when panel is over 9 sq. ft. and bottom edge less than 18" and top edge greater than 36" above floor) )C Fireplaces & Hearth Extensions masonry (built as per plans) Bathroom Ventilation (either operable window or fan that vents directly to outside) A inks, Bathtubs and Showers (check for caulking, operation and leaks) %tairway Illumination (switch at top and bottom) FRAMING CHECKLIST Date f-2.1-/- Building Permit Number: /?o /-- /o -dam Project: Pte- / sae- 77 / (gilt q) Job Address: The following comments based on the 1998 edition of the International One and Two Family Dwelling Code should be resolved before an occupancy permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International One and Two Family Dwelling Code or any federal, state or local regulations. 6 May 02 Exterior Concrete Slabs (3 1/2 " min. thickness & 4" gravel base min.) / Exterior Wall Plywood & OSB (nail or staple - 6" o. c. at edges & 12" o. c. in field) 7 Adequate uplift control at floor line (sheathing or 1 %2 X 36" straps 4' o. c. mudsill to studs) Seismic hold -downs at garage corners <4' wide Foundation Water - proofing (check to see if complete) _ Crawl space ventilation 1 sf per 150sf (w/ vapor barrier 1 sf per 1500sf) within 3' of corner Cripple Walls (braced as normal walls if over 14 ", under 14" they must be solidly sheathed 4 ud Sill (bolts in proper location, nuts tightened, pressure treated or redwood, joints blocked or under stud at wall and gaps grouted or shimmed) Frame /Floor Sheathing and nailing Typ. 3/4" T &G - 6" on edges & 12" in field) perpendicular to joist ) ,Joist Spacing and Size (as per plans) /Bearing (1 -1/2" min.) & Lapping (3" min. where joists lap over wall or beam) /Notching (depth -1/6 max., length -1/3 depth max., not in middle 1/3, ends- 1/4 depth max.) TJI -NO /Boring (1/3 "d" max, >2" of top or bottom or another hole or notch) TJI see chart /Cantilevers- Blocking, reinforcement, span and spacing as per plans. /Plumbing, Electrical and HVAC (check for notching, cutting and boring of joists) /Joists Under Load Bearing Partitions (shall be doubled as per Section 502.3.3, if plumbing space needed, the joists shall be blocked 4' o. c.) Girders and Beams (as per plans, nailed or mechanically connected to frame and proper bearing) /Header Joists (doubled if over 4') Multiple joists carrying headers shall be doubled or tripled /Joist Hangers (check location & nailed properly) Draft Stop (required for over 1000 sq ft. of unusable space at floor /ceiling) /Duct Supports metal - < 10' spacing & Flexible — < 4' max — (2" sag in 4') /lothes Dryer Ducts (solid metal ducts, no screws extending into duct & vent directly to outside) /uuct insulation (insul. in non cond. space May. 6, 02 'Basement Walls (pressure treated or redwood sill plate properly fastened to slab) FINAL INSPECTION CHECKLIST Date: ( - a, Project: 1?tr ;dg Job Address: 50 C• • Building Permit Number: The following comments based on the 2000 edition of the International Residential Code should be resolved before an occupancy permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International Residential Code or any federal, state or local regulation. 1 OUTSIDE House Numbers (visible from the street) /Grade (yard is sloped away from foundation) /idewalk & Landscape Strip 5' wide (W/ 6" of granular borrow (hill 12 ")) - -7' LS strip r Front Setback Coverage 60% min green Windows - Covers and Screens (shall be releasable or removable from the inside for egress Window Wells min. 24" clear (out and above) well !Exterior Steps (7 3/4 " max. rise & 10" min. tread) .4tairway Handrails 4 or more risers or over 30" ( <4" max. spacing of uprights) /Guardrails (provide if over 30" above floor /grade & 4" max sphere spacing for uprights) /Landings (36" x 36" min., (not req. the top of the stair if a door does not swing over stairs) /Thresholds 1 1/2" max. above floor or landing (7 3/4" max if door does not swing over landing) ,osts (required to be treated, redwood or cedar if in contact of concrete / earth) /Roofing (no apparent leaks, installed properly and roofing as per plans) / Masonry (lintels as per table 703.7. 1) /Roof Ventilation (as per plans) INSIDE Z Egress Doors (all egress doors must be able to open from inside without use of keys or tools) /Window Energy calc's: match actual window l afe Glazing provided in all doors, within 24" of door arc and below 60 ", & in tub enclosure bo r ,eij t ' Bathroom Ventilation (either operable window or fan that vents directly to outside) /Sinks, Bathtubs and Showers (check for caulking, operation and leaks) Stairway Illumination (switch at top and bottom) /Stairs (7 3/4 "max. riser, 10'" min. tread, (nosing 3/4" to 1 1/4" with solid risers) .!Handrails Cont (34" to 38 ", 1 1/2" to wall, and grip 1 1/4" to 2" dia. upright < 4 ",triangular space 6" max ) Date: 7. 2Z Project: Far al& Job Address: g(,Z 6 Building Permit Number: FINAL INSPECTION CHECKLIST The following comments based on the 2000 edition of the International Residential Code should be resolved before an occupancy permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the /ntemational Residential Code or any federal, state or local regulation. OUTSIDE House Numbers (visible from the street) G rade (yard is sloped away from foundation) Aidewalk & Landscape Strip 5' wide (\N/ 6" of granular borrow (hill 12 ")) - -7' LS strip Front Setback Coverage 60% min green Windows - Covers and Screens (shall be releasable or removable from the inside for egress Z Window Wells min. 24" clear (out and above) well Exterior Steps (7 3/4 " max. rise & 10" min. tread) /Stairway Handrails 4 or more risers or over 30" ( <4" max. spacing of uprights) /ardrails (provide if over 30" above floor/ grade & 4" max sphere spacing for uprights) g p p 9 /Landings (36" x 36" min., (not req. the top of the stair if a door does not swing over stairs) Thresholds 1 1/2" max above floor or landing (7 3/4" max if door does not swing over landing) /Posts (required to be treated, redwood or cedar if in contact of concrete / earth) / (no apparent leaks, installed properly and roofing as per plans) /Masonry (lintels as per table 703.7. 1) / Ventilation (as per plans) INSIDE isgress Doors (all egress doors must be able to open from inside without use of keys or tools) zWindow Energy calc's: match actual window /fety Glazing provided in all doors, within 24" of door arc and below 60 ", & in tub enclosure �athroom Ventilation (either operable window or fan that vents directly to outside) inks, Bathtubs and Showers (check for caulking, operation and leaks) S tairway Illumination (switch at top and bottom) /Stairs (7 3/4 "max. riser, 10" min. tread, (nosing 3 /4 "to 1 1/4" with solid risers) r andrails Cont (34" to 38 ", 1 1/2" to wall, and grip 1 1/4" to 2" dia. upright < 4 ",triangular space 6" max ) Designed By • ott Spaulding, P.E. Checked By: Date: Date: Design Intelligence, LLC Engineering Calculations Summary Date: July 27, 2001 Subject: Parkside Planned Residential Development Townhouses /Garages , Rexburg, Idaho Customer: Gerorgetown Development This analysis uses the Design Criteria required by the local jurisdiction and the 1997 UBC as the basis for the calculations. Materials: Dimensional Lumber - UBC Design Values Used Concrete: 3000 psi @ 28 days Reinforcing Steel - fy = 60,000 psi Assumptions: UBC 1997 — Foundations designed for Max Brg Pressure of 2000 psf Design Loads: Snow = 35 psf Seismic = Seismic Zone 3 Wind = 80 mph, Exposure C References: Uniform Building Code, 1997 Edition Customer Drawings TrusJoist MacMillian Design Guides Summary: All beam sizes and footing sizes are noted on the drawings. These calculations and included details are for this location and customer only and not to be reused in any manner without the written consent of Design Intelligence. Design Intelligence 466 South 3rd East Rexburg, Idaho 83440 Design Loads Snow Load: Wind Load Seismic Snow Loads Roof Pitch Roof Pitch Roof Pitch Roof Pitch Roof Pitch Roof Pitch Wind Loads Seismic Loads Rise Run Reduction 3 12 0.0 psf 4 12 0.0 psf 6 12 2.5 psf 8 12' 5.1 psf 10 12' 7.4 psf 12 12'i 9.4 psf P= Ce *Cq *qs *Iw qs = 16.4 psf Ph = V= Zone 3, 35 psf 80 mph 25.4 13.7 psf psf 2.5 *Ca *I *W /R 0.164 W PARKSIDE PRD 7/27/01 70 mph 12.6 Horizontal Vertical 1 0.12 Ca= 0.36 I= Page 1 Use 35.0 35.0 32.5 29.9 27.6 25.6 qs 80 mph 16.4 Ce 1.19', Exposure C Cq 1.3 Horizontal 2A 0.22 psf psf psf psf psf psf 90 mph 20.8 .7 Vertical Ca - Zone 2B 0.28 3 4 0.36 0.44 R = . 5.5 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam 1 Main Floor Support -19' Apartment Type GLB Fb psi 1600 Fv psi 165 E psi 1500000 Span = 19 ft Tributary Area = 11 ft Loads 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40 psf 440 Ibs /ft Dead Load 15' psf 165 Ibs /ft Moment Live Load Moment = 19855 lb-ft = 238260 lb-in Dead Load Moment = 7446 lb-ft = 89348 lb-in Section Modulus Required = 204.75 in3 Section Width = 5.125' in Section Depth = 18 in Section Modulus Provided = 276.8 in3 OK Moment of Ineritia Provided = 2490.8 in4 Deflection Live Load = 0.03 in. L/360 0.63 in. OK Dead Load = 0.13 in. Total = 0.16 in. U240 0.95 in. OK Horizontal Shear fv = 93 psi OK FV = 165 psi Allowable Use 5.125 X 18 GLB liesign Intelligence 466 South 3rd East Rexbur2.Idaho 83440 PARKSIDE PRD Page 1 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam 2 Main Floor Joist Type DF Fb psi 1300 Fv psi 95 1233 E psi 1900000 Span = ft Tributary Area = 1 ` ft Loads 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40 psf 53.2 Ibs /ft Dead Load 15 psf 19.95 Ibs /ft Moment Live Load Moment = 1011 lb-ft = 12131.91 lb-in Dead Load Moment = 379 lb-ft = 4549 lb-in Section Modulus Required = 12.83 in3 Section Width = 15 in Section Depth = 7.25 in Section Modulus Provided = 13.1 in3 OK Moment of Ineritia Provided = 47.6 in4 Deflection Live Load = 0.23 in. L/360 0.41 in. OK Dead Load = 0.11 in. Total = 0.34 in. U240 0.6165 in. OK Horizontal Shear fv = 62 psi OK FV = 95 psi Allowable Use 1.5 X 7.25 DF liosign Intelligence 466 South 3rd East Rexburg, Idaho 83440 PARKSIDE PRD Page 2 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam 3 Main Floor Support -16' Apartment Type GLB Fb psi 1600 Fv psi 165 1 6 E psi 1500000 Span = ft Tributary Area = 11 ft Loads 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40 psf 440 Ibs /ft Dead Load 15 psf 165 Ibs /ft Moment Live Load Moment = 14080 lb-ft = 168960 lb-in Dead Load Moment = 5280 lb-ft = 63360 lb-in Section Modulus Required = 145.20 in3 Section Width = 5.125 in Section Depth = 16.5' in Section Modulus Provided = 232.5 in3 OK Moment of Ineritia Provided = 1918.5 in4 Deflection Live Load = 0.02 in. L/360 0.53 in. OK Dead Load = 0.08 in. Total = 0.11 in. L/240 0.8 in. OK Horizontal Shear fv = 86 psi OK FV = 165 psi Allowable Use 5.125 X 16.5 GLB design Intelligence 466 South 3rd East Rexburg.Idaho 83440 PARKSIDE PRD Page 3 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB1 Second Floor Support - 16' Apartment Type GLB Fb psi 1600 Fv psi 165 8.5 E psi 1500000 Span = ft Tributary Area = 7.5 ft Loads Snow 0 psf Uniform Load = 0 Ibs /ft Live Load 40 psf 300 Ibs /ft Dead Load 15' psf 112.5 Ibs /ft Moment Live Load Moment = 2709 lb-ft = 32512.5 lb-in Dead Load Moment = 1016 lb-ft = 12192 lb-in Section Modulus Required = 27.94 in3 Section Width = 3.125' in Section Depth = 12 in Section Modulus Provided = 75.0 in3 OK Moment of Ineritia Provided = 450.0 in4 Deflection Live Load = 0.01 in. U360 0.28 in. OK Dead Load = 0.02 in. Total = 0.03 in. U240 0.425 in. OK Horizontal Shear fv = 70 psi OK FV = 165 psi Allowable Use 3.125 X 12 GLB Design Intelligence 466 South 3rd East Rexburg, Idaho 83440 PARKSIDE PRD Page 4 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB2 Second Floor Support -16' Apartment Type DF Fb psi 1300 Fv psi 95 3 E psi 1900000 Span = ft Tributary Area = 6 ft Loads Snow 0 psf Uniform Load = 0 Ibs /ft Live Load 40 psf 240 Ibs /ft Dead Load 15 psf 90 Ibs /ft Moment Live Load Moment = 270 lb-ft = 3240 lb-in Dead Load Moment = 101 lb-ft = 1215 lb-in Section Modulus Required = 3.43 in3 Section Width = 3 in Section Depth = 9.25 in Section Modulus Provided = 42.8 in3 OK Moment of Ineritia Provided = 197.9 in4 Deflection Live Load = 0.00 in. L/360 0.10 in. OK Dead Load = 0.00 in. Total = 0.00 in. U240 0.15 in. OK Horizontal Shear fv = 27 psi OK FV = 95 psi Allowable Use 3 X 9.25 DF Design Intelligence 466 South 3rd East Rexburg, Idaho 83440 PARKSIDE PRD 7/27/01 Page 5 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB3 Second Floor Support -16' Apartment Type DF Fb psi 1300 Fv psi 95 4 E psi 1900000 Span = ft Tributary Area = 10 ft Loads Snow 0 psf Uniform Load = 0 Ibs /ft Live Load 40 psf 400 Ibs /ft Dead Load 15 psf 150 Ibs /ft Moment Live Load Moment = 800 lb-ft = 9600 lb-in Dead Load Moment = 300 lb-ft = 3600 lb-in Section Modulus Required = 10.15 in3 Section Width = -, 45' in Section Depth = 7.25: in Section Modulus Provided = 39.4 in3 OK Moment of Ineritia Provided = 142.9 in4 Deflection Live Load = 0.00 in. L/360 0.13 in. OK Dead Load = 0.00 in. Total = 0.00 in. L/240 0.2 in. OK Horizontal Shear fv = 51 psi OK FV = 95 psi Allowable Use 4.5 X 7.25 DF Design Intelligence 466 South 3rd East Rexbur2.Idaho 83440 PARKSIDE PRD Page 6 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB4a Second Floor Support - 16' Apartment - NOT USED Type DF Fb psi 1300 Fv psi 95 E psi 1900000 4 Span = ft Tributary Area = 10 ft Loads 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40! psf 400 Ibs /ft Dead Load 15 psf 150 lbs/ft Moment Live Load Moment = 800 lb-ft = 9600 lb-in Dead Load Moment = 300 lb-ft = 3600 lb-in Section Modulus Required = 10.15 in3 4.5 7.25' Section Width = in Section Depth = in Section Modulus Provided = 39.4 in3 OK Moment of Ineritia Provided = 142.9 in4 Deflection Live Load = 0.00 in. L/360 0.13 in. OK Dead Load = 0.00 in. Total = 0.00 in. L/240 0.2 in. OK Horizontal Shear fv = 51 psi OK FV = 95 psi Allowable Use 4.5 X 7.25 DF 15esign Intelligence 466 South 3rd East RexburQ.Idaho 83440 PARKSIDE PRD 7/27/01 Page 7 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB4b Second Floor Support - 16' Apartment Type LVL Fb psi 2600 Fv psi 285 11 E psi 1900000 Span = ft Tributary Area = 11 ft Loads 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40 psf 440 Ibs /ft Dead Load 15', psf 165 Ibs /ft Moment Live Load Moment = 6655 lb-ft = 79860 lb-in Dead Load Moment = 2496 lb-ft = 29948 lb-in Section Modulus Required = 42.23 in3 Section Width = .5 in Section Depth = 11.875 in Section Modulus Provided = 82.3 in3 OK Moment of Ineritia Provided = 488.4 in4 Deflection Live Load = 0.01 in. L/360 0.37 in. OK Dead Load = 0.06 in. Total = 0.07 in. L/240 0.55 in. OK Horizontal Shear fv = 120 psi OK FV = 285 psi Allowable Use 3.5 X 11.875 LVL Design Intelligence 466 South 3rd East Rexburg. Idaho 83440 PARKSIDE PRD 7/27/01 Page 8 liesign Intelligence 466 South 3rd East Rexburg, Idaho 83440 PARKSIDE PRD Type Fb psi LVL GLB DF Beam RB1a Type GLB Span = Tributary Area = Moment Section Width = Section Depth = Deflection Live Load = Dead Load = Total = fv = FV = 2600 1600 1300 Loads Live Load Moment = Roof Support - 16' Apartment Horizontal Shear 152 195 Fv psi 285 165 95 psf psf 5 psf 6 ft 19_ ft Section Modulus Provided = Moment of Ineritia Provided = 0.07 0.03 0.10 psi psi E psi 1900000 1500000 1900000 Fb psi Fv psi E psi 1600 195 1500000 Snow Live Load Dead Load 2993 lb-ft Dead Load Moment = 1283 lb-ft Section Modulus Required = 42.2 189.8 in. in. in. OK Allowable Use Uniform Load = 32.06 in3 in4 U360 L/240 3.125 35910 15390 in3 0.20 0.3 X 665 0 285 lb-in in. in. 9 Ibs /ft Ibs /ft Ibs /ft lb-in OK OK OK GLB Page 9 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam RB1b Roof Support -16' Apartment - NOT USED Type GLB Fb psi 1600 Fv psi 195 6 E psi 1500000 Span = ft Tributary Area = 19 ft Loads 35 Snow psf Uniform Load = 665 Ibs /ft Live Load 0 psf 0 Ibs /ft Dead Load 15 psf 285 Ibs /ft Moment Live Load Moment = 2993 lb-ft = 35910 lb-in Dead Load Moment = 1283 lb-ft = 15390 lb-in Section Modulus Required = 32.06 in3 Section Width = 3.125 in Section Depth = 9 in Section Modulus Provided = 42.2 in3 OK Moment of Ineritia Provided = 189.8 in4 Deflection Live Load = 0.07 in. U360 0.20 in. OK Dead Load = 0.03 in. Total = 0.10 in. L/240 0.3 in. OK Horizontal Shear fv = 152 psi OK FV = 195 psi Allowable Use 3.125 X 9 GLB Design Intelligence 466 South 3rd East Rexburg. Idaho 83440 PARKSIDE PRD Page 10 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam RB2 Roof Support - 16' Apartment Type DF Fb psi 1300 Fv psi 95 E psi 1900000 3 Span = ft Tributary Area = 19 ft Loads 35! Snow psf Uniform Load = 665 Ibs /ft Live Load 0 psf 0 Ibs /ft Dead Load 15', psf 285 Ibs /ft Moment Live Load Moment = 748 lb-ft = 8977.5 lb-in Dead Load Moment = 321 lb-ft = 3848 lb-in Section Modulus Required = 9.87 in3 Section Width = 3' in Section Depth = 9.25! in. Section Modulus Provided = 42.8 in3 OK Moment of Ineritia Provided = 197.9 in4 Deflection Live Load = 0.00 in. L/360 0.10 in. OK Dead Load = 0.00 in. Total = 0.00 in. L/240 0.15 in. OK Horizontal Shear fv = 77 psi OK FV = 95 psi Allowable Use 3 X 9.25 DF Design Intelligence 466 South 3rd East Rexbur Idaho 83440 PARKSIDE PRD Page 11 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB1 Second Floor Support -19' Apartment - NOT USED Type GLB Fb psi 1600 Fv psi 165 9 ; E psi 1500000 Span = ft Tributary Area = 7.5 ft Loads 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40 psf 300 Ibs /ft Dead Load 15' psf 112.5 Ibs /ft Moment Live Load Moment = 3038 lb-ft = 36450 lb-in Dead Load Moment = 1139 lb-ft = 13669 lb-in Section Modulus Required = 31.32 in3 Section Width = 3.125 in Section Depth = 12' in Section Modulus Provided = 75.0 in3 OK Moment of Ineritia Provided = 450.0 in4 Deflection Live Load = 0.01 in. L/360 0.30 in. OK Dead Load = 0.02 in. Total = 0.03 in. L/240 0.45 in. OK Horizontal Shear fv = 74 psi OK FV = 165 psi Allowable Use 3.125 X 12 GLB Design Intelligence 466 South 3rd East Rexbure.Idaho 83440 PARKSIDE PRD 7/27/01 Page 12 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB2 Second Floor Support -19' Apartment Type GLB Fb psi 1600 Fv psi 165 8 E psi 1500000< Span = ft Tributary Area = 6.5 ft Loads Snow 0 psf Uniform Load = 0 lbs/ft Live Load 40 psf 260 Ibs /ft Dead Load 25', psf (included wall above) 162.5 Ibs /ft Moment Live Load Moment = 2080 lb-ft = 24960 lb-in Dead Load Moment = 1300 lb-ft = 15600 lb-in Section Modulus Required = 25.35 in3 Section Width = 1.125! in Section Depth = 12 in Section Modulus Provided = 75.0 in3 OK Moment of Ineritia Provided = 450.0 in4 Deflection Live Load = 0.01 in. U360 0.27 in. OK Dead Load = 0.02 in. Total = 0.03 in. L/240 0.4 in. OK Horizontal Shear fv = 68 psi OK FV = 165 psi Allowable Use 3.125 X 12 GLB Design Intelligence 466 South 3rd East Rexburg, Idaho 8344 PARKSIDE PRD Page 13 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB3 Second Floor Support -19' Apartment Type LVL Fb psi 2600 Fv psi 285 E psi 1900000 11 Span = ft Tributary Area = 11 ft Loads 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40 psf 440 Ibs /ft Dead Load 15 psf 165 Ibs /ft Moment Live Load Moment = 6655 lb-ft = 79860 lb-in Dead Load Moment = 2496 lb-ft = 29948 lb-in Section Modulus Required = 42.23 in3 Section Width = 3.5 in Section Depth = 11.875 in Section Modulus Provided = 82.3 in3 OK Moment of Ineritia Provided = 488.4 in4 Deflection Live Load = 0.01 in. U360 0.37 in. OK Dead Load = 0.06 in. Total = 0.07 in. U240 0.55 in. OK Horizontal Shear fv = 120 psi OK FV = 285 psi Allowable Use 3.5 X 11.875 LVL Design Intelligence 466 South 3rd East Rexbure.Idaho 83440 PARKSIDE PRD Page 14 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB4 Second Floor Support -19' Apartment Type GLB Fb psi 1600 Fv psi 165 E psi 1500000 8 Span = ft Tributary Area = 7.5 ft Loads 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40 psf 300 Ibs /ft Dead Load 15 psf 112.5 Ibs /ft Moment Live Load Moment = 2400 lb-ft = 28800 lb-in Dead Load Moment = 900 lb-ft = 10800 lb-in Section Modulus Required = 24.75 in3 Section Width = 3.125; in Section Depth = 12 in Section Modulus Provided = 75.0 in3 OK Moment of Ineritia Provided = 450.0 in4 Deflection Live Load = 0.01 in. L/360 0.27 in. OK Dead Load = 0.02 in. Total = 0.02 in. L/240 0.4 in. OK Horizontal Shear fv = 66 psi OK FV = 165 psi Allowable Use 3.125 X 12 GLB Design Intelligence 466 South 3rd East Rexbur2.Idaho 83440 PARKSIDE PRD Page 15 7/27/01 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB5 Second Floor Support -19' Apartment Type DF Fb psi 1300 Fv psi 95 E psi 1900000 3 5 .5 Span = ft Tributary Area = ft Loads 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40 psf 220 Ibs /ft Dead Load 15 psf 82.5 Ibs /ft Moment Live Load Moment = 248 lb-ft = 2970 lb-in Dead Load Moment = 93 lb-ft = 1114 lb-in Section Modulus Required = 3.14 in3 Section Width = 3 in Section Depth = 9.25 in Section Modulus Provided = 42.8 in3 OK Moment of Ineritia Provided = 197.9 in4 Deflection Live Load = 0.00 in. L/360 0.10 in. OK Dead Load = 0.00 in. Total = 0.00 in. U240 0.15 in. OK Horizontal Shear fv = 25 psi OK FV = 95 psi Allowable Use 3 X 9.25 DF Design Intelligence 466 South 3rd East Rexbur Idaho 83440 PARKSIDE PRD 7/27/01 Page 16 Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam MB6 Roof Support - 19' Apartment Type DF Fb psi 1300 Fv psi 95 5 E psi 1900000 Span = ft Tributary Area = 10 ft Loads 0 40 Snow psf Uniform Load = 0 Ibs /ft Live Load psf 400 Ibs /ft Dead Load 15 psf 150 Ibs /ft Moment Live Load Moment = 1250 lb-ft = 15000 lb-in Dead Load Moment = 469 lb-ft = 5625 lb-in Section Modulus Required = 15.87 in3 Section Width = 45 in Section Depth = 7.25' in Section Modulus Provided = 39.4 in3 OK Moment of Ineritia Provided = 142.9 in4 Deflection Live Load = 0.00 in. L/360 0.17 in. OK Dead Load = 0.01 in. Total = 0.01 in. L/240 0.25 in. OK Horizontal Shear fv = 63 psi OK FV = 95 psi Allowable Use 4.5 X 7.25 DF Design Intelligence 466 South 3rd East Rexbur Idaho 83440 PARKSIDE PRD Page 17 7/27/01 Type v � Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 1600 165 1500000 DF 1300 95 1900000 Beam RBI Roof Support -16' Apartment Type DF Fb psi 13 00 Fv psi 95 4 E psi 1900000 Span = ft Tributary Area = 19 ft Loads Snow Live Load 35 psf Uniform Load = 665 Ibs /ft U 15', psf 0 lbs/ft Dead Load psf 285 Ibs /ft Moment Live Load Moment = 1330 lb-ft = 15960 lb-in Dead Load Moment = 570 lb-ft = 6840 lb-in Section Modulus Required = 17.54 in3 Section Width = 3 in Section Depth = 9.25 in Section Modulus Provided = 42.8 in3 OK Moment of Ineritia Provided = 197.9 in4 Deflection Live Load = 0.01 in. L/360 0.13 in. OK Dead Load = 0.00 in. Total = 0.01 in. L/240 0.2 in. OK Horizontal Shear fv = 103 psi NG (OK Snow) FV = 95 psi Allowable Use 3 X 9.25 DF Design Intelligence 466 South 3rd East PARKSIDE PRD 7/27/01 Page 18 besign Intelligence 466 S 3rd E Rexburg, Idaho 83440 PARKSIDE PRD Spread Footing Design Values Spread Footing - Ridge Beam Support - F1 Description Roof Live Load Roof Dead Load Rebar Size = Use Load Calculated Footing Width = #4 5 91 psf 15 psf 32 Calculated Minimum Reinforcing = Area = #4 Load Length 2000 psf 0.002 3000 psi 60000 psi Load Width Total Load in. 0.864 in *in 0.2 in *in Bars Each Way Load 14098 in. Wide X 1 in. Deep Footing Page 1 7/27/01 Foundation Design UBC 1997 35! Allowable Bearing Capacity 2000 psf Max Roof Span = ft Max Floor Span = 19 ft Snow Load 35 psf Wall Height = 17 ft Floor Live Load 80' psf Stem Wall Height = 4 8 ft Wall Dead Load 15 15, psf Stem Wall Width = in Roof Dead Load psf Brick Dead Load 0 psf Floor Dead Load 30 psf Exterior Bearing Walls Proposed Footing Roof Loads 875 Ibs /ft Width 20 in Floor Loads 1045 Ibs /ft Depth 10 in Wall Load 255 Ibs /ft Stem Wall Load 400 Ibs /ft Footing Load 208 Ibs /ft Total 2783 Ibs /ft Bearing Pressure = 1670 psf OK Reinforcing Requirements Min Reinforcing Factors Footing 0.002 Stem Wall Vertical 0.0012 0.2' Horizontal 0.002 Reinforcing Bar #4 in *in Footing Continuous Reinforcing Count 2 bars Transverse - Reinforcing Spacing 10 in. Stem Wall Continuous Reinforcing Count 4 bars Vertical - Reinforcing Spacing 18 in. Upsign Intelligence 466 So. 3rd East Rexburg. Idaho 83440 PARKSIDE PRD Page 1 7/27/01 Foundation Design UBC 1997 24 Allowable Bearing Capacity 2000 psf Max Roof Span = ft 35' Max Floor Span = 0 ft Snow Load psf Wall Height = 8 ft Floor Live Load 40 psf Stem Wall Height = 4 ft Wall Dead Load 15 psf Stem Wall Width = 8 in. Roof Dead Load 15', psf Brick Dead Load 0 15 psf Floor Dead Load psf Garage Exterior Bearing Walls Proposed Footing Roof Loads 600 Ibs /ft Width 16 in Floor Loads 0 Ibs /ft Depth 10 in Wall Load 120 Ibs /ft Stem Wall Load 400 Ibs /ft Footing Load 167 Ibs /ft Total 1287 Ibs /ft Bearing Pressure = 965 psf OK Reinforcing Requirements Min Reinforcing Factors Footing 0.002 Stem Wall Vertical 0.0012 #4 0.2 Horizontal 0.002 Reinforcing Bar in *in Footing Continuous Reinforcing Count 2 bars Transverse - Reinforcing Spacing 10 in. Stem Wall Continuous Reinforcing Count 4 bars Vertical - Reinforcing Spacing 18 in. Design Intelligence 466 So. 3rd East Rexb PARKSIDE PRD Page 2 7/27/01 Shear Wall Analysis - Short Wall 25.4 Wind Load = psf 9 Roof Height = ft Wall Height = 18 19 ft Length of Long Wall = ft Area at Mid Height of Wall = 342 ft^2 Wind Force = 8687 Ibs Shear Wall Length 33 ft Shear /ft in Wall @ Mid Height 263 Ibs /ft Provide 15/32 APA Rated Sheath ng with 8d nails at 6" o.c. at panel edges and 12" o.c. in the field. Blocking required. Seismic Analysis Seismic Multiplier = 0.164 Width Length Load Weight Roof Dead Load 35 19 24 15960 Ibs (includes snow) Long Wall Length 19! ft Short Wall Length 3 f Height Length Load Weight Wall Dead Load 9 104 % 15 7020 Ibs Seismic Force @ Mid Height of Wall 3769 Ibs 33; Shear Wall Length ft Shear per ft in Wall @ Mid Height 114 Ibs /ft OK Provide 15/32 APA Rated Sheathing with 8d nails at 6" o.c. at panel edges and 12" o.c. in the field. Blocking required. L)Qsign Intelligence 466 South 3rd East PARKSIDE PRD Page 1 7/27/01 Shear Wall Analysis - Garage 25.4' 1 f Wind Load = psf Roof Height = ft Wall Height = 8i ft Length of Long Wall = 92; 874 ft Area at Mid Height of Wall = ft ^2 Wind Force = 22200 Ibs 80 Shear Wall Length ft Shear /ft in Wall @ Mid Height 277 Ibs /ft Provide 15/32 APA Rated Sheathing with 8d nails at 6" o.c. at panel edges and 12" o.c. in the field. Blocking required. U" @sign Intelligence 466 South 3rd East Rexburg, Idaho 83440 PARKSIDE PRD Page 2 7/27/01 1446 -e) a4w ' 8 - (c(r d 6 ett (21/4 - /45're'= / 6, 7 ay /6a) 74." a/ et-thf CQ 5% x /8 `,' 771.4:1 h coo LAS S i..0._) dL. /4- . - �8 , 21, i5 / ak.v se zit eo ltc..1..) ( (e/ (�7 4 , 4i di h'l.-G't/(� 1 /`-` -f! 4/Lt (/'C,' = C 7 Kl 66 / /2 IF 34 on ,(/g (Z2 / /¢xa /g ✓L �Q,1 -LL /4 7/ ` ( 1 7 . / eel 5"% x l ? 6 „ / 54 /3.40 c%,< g "1 � Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 2400 165 1500000 DF 1300 95 1900000 Beam 1 BB1 19' Unit Type GLB Fb psi 1600 Fv psi 165 E psi " 1500000 Span = 1 7.67 ft Tributary Area = 1' 1 ft Loads Point Load = 3295 Ibs 0 Snow psf Uniform Load = 0 Ibs /ft Live Load 40 psf 440 Ibs /ft Dead Load 15 psf 165 Ibs /ft Moment Live Load Moment = 31728 lb-ft = 380739 lb-in Dead Load Moment = 6440 lb-ft = 77277 lb-in Section Modulus Required = 286.26 in3 Section Width = 5.125; in Section Depth = 18 in Section Modulus Provided = 276.8 in3 NG Moment of Ineritia Provided = 2490.8 in4 Deflection Live Load = 0.20 in. L/360 0.59 in. OK Dead Load = 0.10 in. Total = 0.30 in. L/240 0.8835 in. OK Horizontal Shear fv = 140 psi OK FV = 165 psi Allowable Reaction = 6992.675 Ibs Use 5.125 X 18 GLB Design Intelligence 466 South 3rd East Rexbure,Idaho 83440 KOZY KABINS Page 1 8/27/01 Design Intelligence 466 South 3rd East Rexburg, Idaho 83440 KOZY KABINS 8/27/01 Type Fb psi LVL 2600 GLB 2400 DF Beam 2 Type GLB Span = Tributary Area = Loads Snow 0 psf Live Load 40 psf Dead Load 15 psf Moment Live Load Moment = Dead Load Moment = Section Width = Section Depth = 1300 Fb psi 1600 Fv psi 285 165 95 BB1 16' Unit Fv psi 4.67 ft ft 20609 4439 Section Modulus Required 5.125 in. 16.5 in. Section Modulus Provided = Moment of Ineritia Provided = Deflection Live Load = Dead Load = Total = Horizontal Shear fv = FV = 121 165 0.11 0.06 0.17 psi psi E psi 1900000 1500000 1900000 E psi 165 1500000 lb -ft lb-ft 232.5 1918.5 in. in. in. OK Allowable Use Point Load = Uniform Load = 187.86 in3 in4 L/360 L/240 5.125 247309.8 53264 in3 0.49 0.7335 X 2392 0 440 165 lb-in lb-in in. in. Reaction = 16.5 Ibs Ibs /ft Ibs /ft Ibs /ft OK OK OK 5633.675 GLB Ibs Page 2