HomeMy WebLinkAboutBP, CO & DOCS - 02-00053 - Green Gables II - Three 4-PlexesCITY OF REXBURG
ISSUED TO:
NAME: °"r �� 0E5 th PERMIT # `- ' 6 9- 0
FOR THE CONSTRUCTION OF: 4 * — 3 6 ( 455 JOB ADDRESS: 35 Z) b r.
l
GENERAL CONTRACTOR: R Rile) -\/ 6 4.o .D i
This permit is issued subject to the regulations contained in Building Code and Zoning Regulations of the
City of Rexburg. It is specifically understood that this Permit does not allow any Variance to the regulations
of the City of Rexburg Building or Zoning Codes unless specifically approved by the City Council and
explained on the Building Permit Application as approved by the Building Inspector.
Date Approved Issued By
z3 02
Building Inspector
THIS PERMIT MUST BE PROMINENTLY DISPLAYED AT THE BUILDING SITE
THE BUILDING MAY NOT BE OCCUPIED OR USEDWITHOUT FIRST OBTAINING A CERTIFICATE OF OCCUPANCY .
NOTICE! 1) A complete set of approved drawings along with permit must be kept on the
premises during construction.
2) The permit will b ecome null and void in the event of any deviation from the
accepted drawin
3) No foundation, structural, electrical, nor plumbing work shall be concealed
without approval.
No work shall be done on any part of
the building beyond the point
indicated In each successive
inspection without approval.. No
structural framework of any part of the
building or any underground work
shall be covered or concealed without
approval.
INSPECTION RECORD
BUILDING
1st Layout
2nd Footing
3rd Foundation
4th Truss
5th Framing
6th Drywall
7th Sidewalk
8th Final
9th Occupancy
ELECTRICAL
1st Groundwork
2nd Rough -in
3rd Final
PLUMBING
1st Trench
2nd Service Connection
3rd Rough -in
4th Heat Cable
5th Final
DATE
APPROVED
For Inspections Call 359-3020
24 Hour Notice
A CERTIFICATE OF OCCUPANCY CAN NOT BE ISSUED PRIOR
TO FINAL ELECTRICAL & PLUMBING INSPECTIONS.
CERTIFICATE OF OCCUPANCY
City of Rexburg
Department of Building Inspection
Building Permit No. R- o2 -o9 -o3
Building Street Address: 35o South Pioneer Road
Building Owner: Randy Webb
Contractor: Webb Construction
Description of building or portion of building for which this certificate is
issued:
3 - Four Plex Units
Units 101, 102, 103, 104
Units 201, 202, 203, 204
Units 3oi, 302, 303, 304
Occupancy:
This Certificate, issued rsuant to the requirements of Section tog of tbe Uniform Buibing
Code, certifies that, at t e time of issuance, this buiL?ing or that portion of the buibing that
was inspecteb on the Date listeD was f ouna to be in compliance with tbe requirements of the
code for tbe group and Division of occupancy an tbe use for which the propose? occupancy
was c(assi f ie?.
C.O. Issued by:
Water Department
Full
Date: January 7, 2003 (11:18am
Building Official
There shall be no future change in the existing occupancy classification of the building nor shall
any structural changes, modifications or additions be made to the building or any portion thereof
until the Build' - ; O g icial has reviewed and approved said future chan es.
Fire Department
State of Idaho Electrical Department - (208 - 356-4830) 0
BUIL PERMIT APPLICA REXBURG, ID DATE
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED
OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS.
OWNER
BUILDER
STRUCTURE:
O RESIDENCE
FOOTINGS
O CONCRETE
O MASONRY
0 OTHER
REMARKS:
BUILDING
INSPECTOR
0 NEW
COMM.
O REMODEL
DEPARTMENT OF BUILDING & ZONING
VALUE + ?
FEE PAID 0 CASH
O CHECK
JOB ADDRESS
ARCHITECT
❑ ADDITION
O EDUCATIONAL O GOVT 0 RELIGIOUS
DESIGNER fr
❑ RENEWAL 0 FIRE DAMAGE
0 FENCE 0 PATIO 0 CARPORT 0 GARAGE O AWNING
INSULATED
FOUNDATION
O CONCRETE
0 MASONRY
0 OTHER
BASEMENT
0 PARTIAL
0 FULL
ONO
FLOORS EXT. WALLS
O WOOD 0 WOOD
O CONCRETE 0 MASONRY
O OTHER O COIlN�BETE
❑ VEIR
0 METAL
O STUCCO
INT. WALLS
0 WOOD
0 MASONRY
O CONCRETE
O DRYWALL
0 PLASTER
O TILE
CEILING
0 WOOD
0 DRYWALL
0 PLASTER
0 TILE
O ACOUSTIC
O OPEN
ROOF
O BUILT UR
O WOOD SH.
O COMP. SH.
0 TILE
0 ROLL ROW.
O METAL
HEAT
O GAS
O OIL
O COAL
O FIREPLACE
0 ELECTRIC
This permit is issued subject to the regulations contained in the Uniform Building Code and Zoning Regulations of Rexburg, and it is hereby agreed
that the work to be done as shown in the plans and specifications will be completed in accordance with the regulations
pertaining and applicable thereto: The issuance of the permit does not waive restrictive covenants.
L.)
DATE
O REPAIR
APPUCANT
ADDRESS
PHONE
WHITE- Owner's Copy CANARY -Building Department's Copy PINK - Assessor's Copy GOLDENROD - Inspector
O WALLS
0 CEILING
O FLOORS
O PERIMETER
Date of Application 7
1j
OWNER p�
Name )1 ,
Site Address
Mailing Address
City /State /Zip /Y 4 / 6 //,
Telephone/Fax/Mobile ,l CZ r S : SS A
CONTRACTOR
Name /e
Mailing Address Z‘Z 4 A_
City /State /Zip .42 A 14 �>
Telephone/Fax/Mobile /� j — 575 � if
PROJECT INFORMATION DEPARTMENT APPROVAL
Property Zone: .1-"/Z.)/? Is existing use cpmpatible with zoning, (screening parking, etc)
When was this building last occupied
Architect/ Engineer Firm Plan Name 6YPez-
Subdivision
Circle One Resident a{ Comn�ereial' Educational Government
Circle One New House Addition/Remodel to House
Circle One Basement: No Finished / Unfinished
Lot Square Footage Lot Width
Square Feet Garage Square Feet 40 Number of Stories
What will structure be used for: Home Home Business
Will there be an apartment? ,/l.)
Total Estimated Cost //// v b U X 3
Building Type
Signature of Applicant
* * * * * * * * * * * * * * * * * * * * * * * * * * * * *
APPLICATION FOR BUILDING PERMIT
CITY OF REXBURG, IDAHO
/
Lot
re you in a flood plain /v,.
Permit No. r_0 _p / O3
-tZ -2 /; X �z ? 2jcf
model Other
Block
New Commerci
Other one/ Patio/ Carport/
Commercial Remodel
..
Z- Height of Building
Commercial Other
If so, how many units
Awning N/A
****************************** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Code Building Permit Fees .2, r? Li
Zone Plan Check Fees
Plumbing Permit Fees 9 r e
Digging Permit Fees b
Water &Sewer Fees l a-98 ,
Front Footage Fee c �
TOTAL $ /3 3 C ?!
Signature of Inspector `_"=
Issued by
Rough PlwnbMg
Septic. Tank
Fixtures
Water Piping
Complete
Sewer
CI OF REXBURG
APPLICATION FOR PLUMBING PER
maim
Name
Address TeL
Lot Add.
Name /
Adicss Tel.
NATURE OF INSTALLATION
Use
Skutt winlifs
Kitchen Smks
Floor Drain
Drinking: Fauntains
Wider Softeners
PLUMBER
DES ON OF WORK
Urinal
Sink Trap
Water Heater
Other
Lawn Sprinklers
Plumbing Permit
Sewer Inspection
Inspection of Pipe
Inspection of Fixtures
Received: Date
Rough Plumbing
Sewer
Other
Finish Plumbing
FEES
TOTAL $
INSPECTOR'S RECORD
N
PAM
wa7•y OF RCYll'�1 iP[:
SEP 0 6 2002
I,NSR NAME
1L zorat.-, 4 cra
ilart
Ccincreta:
Masonry :
Roof ing:
sijatjo -/
-
Drywall V72 /J :
Painting: A6\5-
F loo z Cover. Log s:
PI Lunb i_ng:
Heating:
Electrical:
Roc f
,e71
e 20E,
Airi„ clZ CeA
Floc— / Calling Joists:
0-r- 'r
SUBCONTRAgn.R
SPECIAL CONSTRUCTION
(MANuFAcTuRER OR tiPPLIER)
REQUEST FOR A CONDITIONAL BUILDING PERMIT
FOR PARTIAL BUILDING CONSTRUCTION
TO: Building Official for the City of Rexburg
Pursuant to the provisions of the Uniform Building Code, the undersigned requests that a
building permit be issued for:
Footings and Foundations only at:
Acknowledgment is made that the plans for the complex are not complete and that final
approval of the building will not be given until the final plans have been approved. We
recognize that proceeding with partial construction at this time is entirely at the risk of the
Architect/Owner with there being no assurance that the final Certificate of Occupancy for the
entire building or structure will be granted.
We further absolve the City of Rexburg and officers and employees thereof, of all responsibility
for the issuance of a partial permit and further agree that any work performed under this permit
will be removed or otherwise corrected to be in accord with the requirements of the final
approved plans when a permit for the entire building or structure is finally granted.
Dated this 26th day of August, 2002.
Approved:
CITY 0 REXBURG
John Millar
By
Green Gables 11
350 S. Pioneer Rd
Rexburg, Idaho 83440
8/20/2002
Stan Palmer
2916 W 17 South
Idaho Falls, Idaho 83404
Dear Dean,
STATE OF IDAHO
www.ci.rexburg.id.us
P.O. Box 280
12 North Center Street
Rexburg, Idaho 83440
Phone (208) 359 -3020
Fax (208) 359 -3022
e -mail rexburg@ci.rexburg.id.us
I have reviewed the plans for the Randy Webb Apartments and have identified the
following discrepancies, additions - or questions:
1. Identify that setbacks are to eaves.
2. Identify right -of -way lines.
3. Get with John Millar the City of Rexburg Public Works Director and work
out a Development Agreement.
4. Provide details of handicap parking space aisles where they connect to
sidewalk and accessible route into the buildings.
5. Identify trash facilities.
6. Provide minimum foundation reinforcement as per Section 1914.3.5 of the
1997 Uniform Building Code (UBC).
7. All units on lower level must be constructed as "Type B" units as per
Section 1103.1.9.3 of the UBC. Identify as such. Please identify grab bar
backing, accessible thresholds and all other accessible features.
8. Please identify smoke detectors as per the UBC and 2A -10BC fire
extinguishers in each apartment unit. Smoke detectors are required in
each bedroom.
9. Identify that bedroom windows must meet egress as per UBC Section
310.4. Identify the type of windows being provided, The plans show 4'
wide by 3' high windows. Sliders in this size will not meet the minimum
requirements of the UBC. If the windows are a casement variety where
the whole window opens, please identify a maximum sill height. If the
windows are set at header height the sill will probably not meet code.
10. Please identify firewall construction, including draftstops if used. Unit
separation must be maintained from foundation to roof sheathing. Please
provide details in crawl space and attic also.
11. Please identify fire separation at the floors between units. Engineered
joists have their own requirements for fire protection and are not listed in
the UBC. Please provide this information on the plans. One layer of
drywall will not meet manufactures minimum fire requirements for
Please provide me with 2 new copies of any corrected plans. If you have any
questions, please give me a call at 359 -3020 ext. 324.
Val Christensen
Building Official
C.C.
engineered floor joists. Please obtain manufacture's information for fire
resistance.
12. The Building Section on sheet A -5 identifies %2" drywall on the upper
ceiling When trusses are placed on 24" centers, 5/8" drywall is required
on ceilings.
13. On sheet A -5 the Building Section identifies that the floor sheathing is to
be fastened with screws. This practice is not typical. Is it a structural
requirement? If it is required, I will enforce it in the field.
14. Please identify crawl space vent locations to meet requirements of the
UBC. Also identify attic ventilation to meet requirements of the UBC.
15. Please submit a copy of your plans to the State of Idaho Electrical Bureau.
16. I have attached a copy of the Fire Department review to the back of this
document. Please resolve any issues identified by them.
John Millar
Chris Huskinson
REXBURG MADISON COUNTY FIRE DEPARTMENT
P.O. Box 280
26 North Center
Rexburg, Idaho 83440
(208) 359 -3010
1997 Uniform Fire Code Plan Date: 5 -01
Plan Review Review Date: 8 -6 -02
Building Name: RANDY WEBB /KARL AND CHRIS PETERSON APARTMENTS
Building Address: PIONEER ROAD
Stories: TWO Type of Construction: V -N
Occupancy Classification: R -1 Existing Floor Area: N/A
New Construction Floor Area: APPROXIMATELY 2944 SQUARE
FEET /BUILDING
1).Required Fire Flow (Appendix III -A): 1500 GPM /TWO HOURS
Comments: NONE
2).Water Supply (Article 9, Section 903) Required: YES
Fire Hydrant Location: OKAY
Fire Hydrant Flows: UNKNOWN
Fire Flow Test Location: N/A
Fire Flow Supplied By: N/A
Other Approved Water Source: NONE
Water Supply Acceptable: SEE COMMENTS
Fire Hydrant Location Acceptable: YES
Water Supply Comments: PLEASE PROVIDE ESTIMATE OF WATER FLOW FROM
NEW HYDRANT PRIOR TO CONSTRUCTION.
3.)Fire Apparatus Access Roads (Article 9 Section 902)
Required: YES
Acceptable: Width: X Length: X Surface: X
Turning Radius: X Grade: X Vehicle Vertical:
Clearance: Turn Arounds: X
Complete Road Acceptable: YES
Comments: NONE
4).Access Roads and Water Supply, Including Fire Hydrants Are
Required To Be Installed And Made Serviceable Prior To And During
Time Of Construction (Article 9 Section 901.3): YES
Comments: IF NOT INSTALLED AND MADE OPERATIONAL PRIOR TO
CONSTRUCTION A STOP WORK ORDER WILL BE ISSUED.
5),Installation Of Portable Fire Extinguisher (Article 10 Section
1002) Required: YES Location Acceptable: NOT SHOWN
Type Provided Acceptable: SEE COMMENTS
Comments: PROVIDE ONE FIRE EXTINGUISHER IN EACH UNIT, MINIMUM SIZE
OF 2A1OBC EACH.
6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003
Required: NO Type Of System Being Installed:
Sprinkler System Monitoring Required (Article 10 Section 1003.3)
Required: Comments:
7).Standpipes (Article 10 Section 1004) Required: NO
Type Required: Comments:
8).Fire Alarm Systems (Article 10 Section 1007)Required: YES
Type Of System Required: Manual: Automatic: X Both:
Type Of System Being Provided: Manual: Automatic: Both:
Components Of System: Smoke Detectors: X Heat Detectors:
Manual Pull Station:
Door Holders:
Conditions: NONE
Sounding Devices: Visual Devices:
Duct Detectors: Flow Alarm:
Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO
Comments: ALL SLEEPING ROOMS AND CORRIDORS SHALL BE PROVIDED WITH
SMOKE DETECTORS.
10).Other Corrections That Are Required By Special Occupancy Or
Plans As Submitted Are Acceptable: YES, PLEASE ADDRESS ABOVE ITEMS.
Plans Checked By: CHRIS HUSRINSON Date: 8 -6 -02
Please furnish comments back to the plan reviewer in the following
New Plans:
manner: Written Comments: X
Truss ID: A -01 Qty: 20
dame: 2x4 DTL #1 8 Btr. Plating spec : ANSI /TPI - 1995
2.13" " BC
R13 D TC 2x4 DrV #1 S Btr. THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
2.13" Loa 2x4 ran STUD
Loaded for 10 PSF non - concurrent BCLL. PLATE VALVES PER ICBO RESEARCH REPORT #1607.
X -LOC REACT SIZE
1- 2 -12 1993 5.50"
5- 9- 4 1993 5.50"
FORCE AXL BND CSI
-4565 0.25 0.29 0.55
-4073 0.23 0.40 0.63
-2890 0.08 0.44 0.52
-2890 0.08 0.44 0.52
-4073 0.23 0.40 0.63
-4565 0.25 0.29 0.55
FORCE AXL 3-ND CSI
4259 0.61 0.14 0.74
3488 0.50 0.09 0.59
3488 0.50 0.18 0.68
3488 0.50 0.18 0.68
3488 0.50 0.09 0.59
4259 0.61 0.14 0.74
FORCE CSI
-562 0.18
527 0.18
-1013 0.91
1318 0.44
WEB FORCE CSI
5 -11 -1013 0.91
5 -13 527 0.18
6 -13 -562 0.18
SHEPHERD
TRUSS CO.
-IONE (208) 785 -0181
0 FRONTAGE ROAD, BLACKFOOT, 10.83221
T
64-15
3 -10
0-3 -16
1 H
6-3 -1 --1
6-3 -1
6 -0-3
124-4
18 -0-0
4 0
9
9-4 -14
9-4 -14
5-8-12 5-8 -12 6 -04
18 -0-0 23 -8 -12 29 -8 -16
18 -0-0
3-5
4
10
8 -7 -2
18 -0-0
36 -0-0
11
-47)(7
1: 13
8 -7 -2
26 -7 -2
6
1 plates are 20 gauge Truswal Connectors unless preceded by "18" fo! 18 gauge or "H" for 16 gauge, posItioned per Joint Report, unless noted.
WARNING Read all nutrn's on this sheet and give a copy )P1 to the Erecting Contractor.
This design is for an individual building component. 11 has been based on specMcations provided by the component manufacturer and done in
accordance with the latest versions of TPI anti AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions are to be
verified by the component manufacturer andtor building designer prior to fabrication. The building designer shall ascertain that the loads utilized on
this design meet or exceed the loading unposed by the local building code. It is assumed that the top chord is laterally braced by the roof or floor
sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise noted. Bracing shown Is for lateral
support of components members only to redbce buckling length. This component shall not be placed in any environment that will cause the moisture
content of the wood exceed 19% andior taus connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following
standards: 'TRUSCOM MANUAL'. by Truswal, QUALITY CONTROL STANDARD FOR METAL PLATE CONNECTED WOOD TRUSSES' -
4QST.88),'HANDLING INSTALLING AND BRAC NG METAL PLATE CONNECTED W000 TRUSSES' • 44498.91) and '5)8.91 SUMMARY
SHEET' by TPI. The Truss Plate Institute (TPI( is located at 563 D'Onofrio Drive, Madison, Wisconsin 53719. The American Forest and Paper
Association (AFPA) is located at 1250 ConneCtieut Ave, NW, Ste 200, Washington, DC 20036.
6 -3 -1 1
36 -0-0
-4
1 0A
14
9-4 -14
36 -0-0
UPLIFT REACTIONS)
Support 1 -540 lb
Support 2 -540 lb
This truss is designed using'e,.,
UBC Code.
Bldg Enclosed ° Yes
Truss Location ° Not End Zone
Hurricane /Ocean Line ° No , Catego,,
Bldg Length ® 99.00 ft, Bdg Width ° 80''
Mean roof height ° 23.16 ft, mph -
UBC Essential Facility, Dead Load ° 14.5 pea
Eng. Job: .EJ.
Chk: SAF
Dsgnr: SAF
TC Live 35.00 psf
TC Dead 7.50 psf
BC Live 0.00 psf
BC Dead 7.50 psf
TOTAL 50.00 psf
WO: IFIDLB
DurFacs L =1.15 P =1.15
Rep Mbr Bnd 1.15
o.C.Spacing 2- 0- 0
Design Spec UBC
Seqn T6.2.10 - 92956
04-1
Drwg: N
i
6 -9-0
SHIP
MAX DEFLECTION (span)
L/999 IN MEM 10 -11 (LIVE)
Le - 0.41" D. - 0.17" T. -0
maw Joint Locations
1 0- 0- 0 8 0- 0- 0
2 6- 3- 1 9 9- 4 -14
3 12- 3- 4 10 12- 0- 0
4 18- 0- 0 11 18- 0- 0
5 23- 8 -12 12 24- 0- 0
6 29- 8 -15 13 26- 7- 2
7 36- 0- 0 14 36- 0- 0
12/13/2001
Scale: 118" =1'
Name:
X -LOC REACT SIZE
0- 2 -12 993 5.50"
15- 9- 4 993 5.50"
FORM AXL BND CSI
-1476 0.05 0.63 0.68
-1476 0.05 0.63 0.68
FORCE AXL END CSI
1316 0.19 0.32 0.51
1316 0.19 0.32 0.51
REQ'D
1.50"
1.50"
FORCE CSI WEB FORCE CSI
210 0.07
SHEPHERD
TRUSS CO.
'NE (208) 785 -0181
3-4
4
Truss ID: A -02
TC 2x4 DFL #1 & Btr.
BC 2x4 DFL #1'8 Btr.
WEB 2x4 DFL STUD
This truss is designed using the
UBC Code.
Bldg Enclosed a. Yes
Truss Location t. Not End Zone
Hurricane /Ocean Line - Ne Exp Category - C
Bldg Length le 99.00 ft, Bldg Width ® 50.00 £t
Mean roof height o 21.50 £t, mph = 80
UBC Essential Facility, Dead Load a 14.5 psf
8 -0-0
4 00
Plating spec : ANSI /TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OP
MULTIPLE LOAD CASES.
PLATE VALUES PER ICBO RESEARCH REPORT #1607
8 -0-0
8 -0-0
8 -0-0
8 -0-0
16 -0-0
8 -0-0
-4.00
Qty:
8 -0-0
16 -0-0
8 -0-0 6
16 -0-0
)Iates are 20 gauge Truswal Connectors unless preceded by "18" for 18 gauge or "H" for 16 gauge, positioned per Joint Report, unless noted.
WARNING Read all notes n this sheet and give a copy of it to the Erecting Contractor.
This design is for an individual building compnn}nt. It has been based on specifications provided by the component manufacturer and done in
accordance with the latest versions of TPI and AFPA design standards. No responsibility is assumed for dimensional accuracy. Dimensions are to be
verified by the component manufacturer and/or building designer prior to fabrication. The building designer shall ascertain that the loads utilized on
this design meet or exceed the loading Imposedl the local building code. R Is assumed that the top chord is laterally braced by the root or floor
sheathing and the bottom chord )s laterally braced by a rigid sheathing material directly attached, unless otherwise noted. Bracing shown is for lateral
support of components members only to reduce buckling length. This component shall not be placed in any environment that will cause the moisture
content of the wood exceed 19% and/or cause cpnnector plate corrosion. Fabricate, handle, install and brace this truss In accordance with the following
standards: 'TRUSCOM MANUAL'. by Truswal, 'QUALITY CONTROL STANDARD FOR METAL PLATE CONNECTED WOOD TRUSSES' -
(05T -88), 'HANDLING INSTALLING AND BRACING METAL PLATE CONNECTED WOOD TRUSSES' - (HIB -91) and'HIB -91 SUMMARY
) 1.4-0
UPLIFT REACTION (S)
Support 1 -271 lb'
Support 2 -271 lb
Eng. Job: .EJ.
Chk: SAF
Dsgnr: SAF
TC Live 35.00 psf
TC Dead 7.60 psf
BC Live 0.00 psf
BC Dead 7.50 psf
MAX DEFLECTION (span) :
L/999 IN MEM 5 -6 (LIVE)
L. - 0.11" D. - 0.05" T= -0
Joint Locations
1 0- 0- 0 4 0- 0- 0
2 8 -0 -0 5 8 -0 -0
3 16- 0- 0 6 16- 0- 0
12/1 3/2001
WO: IFIDLB
Scale: 174" = 1'
DurFacs L =1.16 P =1.15
Rep Mbr Bnd 1.15
O.C.Spacing 2- 0- 0
Design Spec UBC
X -LOC REACT SIZE REO'D
- 2 -12 1993 5.50" 2.13"
9- 4. 1993 5.50" 2.13"
FORCE AXL BND CSI
-4565 0.25 0.29 0.55
-4073 0.23 0.40 0.63
-2890 0.08 0.44 0.52
- 2890 0.08 0.44 0.52
- 4073 0.23 0.40 0.63
-4565 0.25 0.29 0.55
FORCE AXL BND CSI
4259 0.61 0.14 0.74
3488 0.50 0.09 0.59
3488 0.50 0.18 0.68
3488 0.50 0.18 0.68
3488 0.50 0.09 0.59
4259 0.61 0.14 0.74
FORCE CSI WEB FORCE CSI
-562 0.18 5 -11 -1013 0.91
527 0.18 5 -13 527 0.18
-1013 0.91 6 -13 -562 0.18
1318 0.44
'ICAL PLATE : 2-3
SHEPHERD
TRUSS CO.
)NE(208)785-0181
FRONTAGE ROAD, BLACKFOOT. ID.83221
TC 2x4 DEL #1 S Htr.
BC 2x4 DFL #1 L Btr.
WEB 2x4 DEL STUD
GBL ELK 2x4 DEL STUD
Gable verticals are 2x 4 web material spaced
at 24.0 " o.c. unless noted otherwise.
Top chord supports 24.0 " of uniform load
at 35 psf live load and 8 psf dead load.
Additional design considerations may be
required if sheathing is attached.
Gable members others) e perpendicular
to the plane of the member at intervals.
Bracing is a result of wind loo applied
to member.(Combination axial plus bending).
This truss requires adequate sheathing, as
designed by others, applied to the truss
face providing lateral support for webs in
the truss plane and creating shear wall
action to resist diaphragm loads.
6-3 -1
6-3 -1
6-0-3
12-3-0
18 -0-0
4.p -
3
Plating spec : ANSI /TPI - 1995
THIS DESIGN IS THE COMPOSITE RESULT OF
MULTIPLE LOAD CASES.
PLA
ERF non- RESE�ARCHn REPORT
T. #1607.
Eng. Job: .EJ.
Chit: SAF
Dsgnr: SAF
TC Live 35.00 psf
TC Dead 7.50 psf
BC Live 0.00 psf
BC Dead 7.50 psf
TOTAL 50.00 psf
WO: IFIDLB
DurFacs L =1.15 P=1.15
Rep Mbr Bnd 1.16
O.C.Spacing 2- 0- 0
Design Spec UBC
Seqn T6.2.10 - 92960
5-8 -12 5-8 -12 6-0.3
18-0-0 23 -8 -12 29 -8 -15 36 -0-0
18 -0-0
3-6
4
36 -0-0
9 10 11
9-4-14 8 -7 -2
9.4 -14 18 -0-0
6
6-3 -1 y
7 '
T �
41 it%1
6-3 -15
0 -3 -15 S 4-8 4-6
S=4-8 3-4
12 13
8 -7 -2
26 -7 -2
)fates are 20 gauge Truswal Connectors unless preceded by "18" for18 gauge or "H" for 16 gauge, positioned per Joint Report, unless noted.
WARNING Read all note.I on this sheet and give a copy of it to the Erecting Contractor.
This design is for an individual building compo an t. k has been based on specifications providedby the component manufacturer and done In
accordance with the latest versions of TPI end 1FPA design standards. No responsibility Is assumed for dimensional accuracy. Dimensions era to be
verified by the the loading imposed by he local building codsM� 0 s assumed that hegt pdesign.' c d is late braced by the roof or floor
on
foor
this hi es design meet or
sheathing and the bottom chord is laterally braced by a rigid sheathing material directly attached, unless otherwise noted. Bracing shown is for lateral
support of components members only to reduce buckling length. This component shall not be placed in any environment that will cause the moisture
content of the wood exceed 19% and/or cause connector plate corrosion. Fabricate, handle, install and brace this truss in accordance with the following
standards: 'TRUSCOM MANUAL', by Truswal,'OUALITY CONTROL STANDARD FOR METAL PLATE CONNECTED WOOD TRUSSES' -
(OST- B8).'HANDLING INSTALLING AND BRACIIIG METAL PLATE CONNECTED WOOD TRUSSES' - (HI13-91) and'HI8.91 SUMMARY
SHEET by 791. The Truss Plate Institute (791) is located at 583 D'Onofrio Drive, Madison, Wisconsin 53719. The American Forest and Paper
Association (AFPA) is located at 1250 Connecticut Ave, NW, Ste 200. Washington, DC 20036.
14
9 .4 - 14
36-0-0
Support 1 -540
Support 2 -540 lb
This truss is designed usi
UBC Code.
Bldg Enclosed ar Yes
Truss Location • Not End Sons
B No
99.00 ft, Bld W idth
Mean rooftheight - 23.16 ft, mph
d a 14.5
UBC Essential Facility, Dead
x
0-3 -1
i
6 -9-0
SHIP
MAX DEFLECTION (span)
L/999 IN ISM 10 -11 (LIVE)
L. - 0.41" D. - 0.17" T. -0
owm.= Joint Locations
1 0- 0- 0 8 0- 0- 0
2 6- 3- 1 9 9- 4 -14
3 12- 3- 4 10 12- 0- 0
4 18- 0- 0 11 18- 0- 0
5 23- 8 -12 12 24- 0- 0
6 29- 8-15 13 26- 7- 2
7 36- 0- 0 14 36- 0- 0
12/13/2001
Scale: 1/8" = 1'
A3
\.25%
A3
\1.25"
Rail
A complete TJ -Xpert framing plan includes the True Joist Builder's Guide or Pocket Guide
1.25"/
Plot
ID Length Product
HEADER LIST
Hdl 6' 1 3/4" x 9 1/2" 1.9E Microllam LVL
Hd2 4' 1 3/4" x 9 1/2" 1.9E Microllam LVL
Hd3 3' 1 3/4" x 9 1/2" 1.9E Microllam LVL
JOB COM4ENTS
Randy Webb
Peterson 4 -Plex
Unit # of Net
Qty Plies Qty
2 2 4
1 2 2
1 2 2
Plot
ID Length Product
Plot
ID
LEVEL NOTES
File Name: %*bb- Peterson.JOB
Level Name: Upper Floor
Plot Date: 7/11/01 11:09
Design Date: 6/24/01 22:29
Drawing Scale: 1/8" - 1'
Job Status:
Foundation....Foundation
Main Floor....Ready to Plot
6/24/01 22:42
Upper Floor...Plotted
6/24/01 22:29
NOTE: Level design times indicated above
provide assurance for proper level
stacking. Upper levels must have earlier
design times.
Design Methodology: ASD
Floor Area Loading Is:
40 psf Live Load
12 psf Dead Load
Maximum Joist Deflection:
L/480 Live Load
L/240 Total Load
TJ -Pro Rating Information:
Weighted Average: 46
Lowest Rating: 38
Highest Rating: 52
Glued & Nailed Decking is Assumed
Direct Applied C4ilinq is Assumed
Floor Decking: 23)(32" OSB
Normal 0.C. Spacing " 16 "*
Default Wall / Beam Width: 3.5 "*
Default Header Bearing Length: 1.5 "*
Standard Blocking: Bkl*
TJ -Xpert 6.12 (#676) D
C6.12 D6.12 S6.12 P6.12
*Unless noted otherwise
HANGER LIST - Simpson Strong -Tie Ccopany, Inc.®
H1 6 IUT211
Hanger Notes:
(1) Indicates non - stocked hanger
(5) Backer Blocks Required
ACCESSORIES LIST
Bbl 1' 1/2" or 5/8" Backer Blocks
Rm1 17' 6" 1 1/4" x 11 7/8" 1.3E TimberStrand LSL
Eb 1' 3 1/2" 11 7/8" TJI /Pro -150 Blocking Panels
Bkl 1' 2 1/2" 11 7/8" TJI /Pro -150 Blocking Panels
Shl 4' x 8' 23/32" OSB
J
M
Rd
H
U
Pc
Bk
Eb
0
TRUS JOIST
CT}Xpert.
Qty Product Label Top Nails Face Nails Member Nails Notes
10 -N10 2 -N10 (1)(5)
JOIST AND BEAM LIST
Plot
ID Length Product
J1
J2
J3
J4
M1
42' 11 7/8" TJI /Pro-150 joist
19' 11 7/8" TJI /Pro -150 joist
15' 11 7/8" TJI /Pro -150 joist
4' 11 7/8" TJI /Pro -150 joist
5' 1 3/4" x 11 7/8" 1.5E TimberStrand LSL
Unit # of Net
Qty Plies Qty
9 1 9
12 1 12
31 1 31
2 1 2
1 1 1
Unit # of Net
Qty Plies Qty
12 1 12
12 1 12
1 1 1
18 1 18
49 1 49
CREATED BY
B14C West
1425 North Holmes Ave.
P.O. Box 1831
IDAHO FALLS, ID 83401
208- 522 -5571
FAX: 208 -529 -3610
SYM80L LEGEND
TJI Joist Type
Rectangular Product Type
Bearing 1' 11
Beam
Header
Hanger Type
Hanger Symbol
Parallel Closure Type
Blocking Type
Extra Blocking
(Lineal board length for panels
different from the O.C. spacing)
Point Load
Line Load
Area Load
Detail Callout Label
(See Builder's Guide or Pocket Guide)
Joist Layout Symbol
FOR THE TJ -XPERT WARRANTY
SEE BUILDER'S GUIDE OR POCKET GUIDE
Preliminary Layout
for Review and Approval
REQUIRED BEARING LENGTHS
Bearing
Warning 1 Label Length
i� M1 (19) 1.5"
2� M1 (20) 1.5"
(s) M1 (21) 1.5"
4� M1 (22) 1.5"
Headers not listed require
1.5" of bearing length.
Support widths provide
adequate bearing for
products not listed.
JOIST AND BEAM LIST
Plot Unit 1 of Net
ID Length Product Qty Plies Qty
J1 42' 11 7/8" TJI /Pro -150 joist 15 1 15
J2 15' 11 7/8" TJI /Pro -150 joist 28 1 28
J3 13' 11 7/8" TJI /Pro -150 Joist 3 1 3
J4 2' 11 7/8" TJI /Pro -150 joist 2 1 2
M1 15' 1 3/4" x 11 7/8" 1.5E TimberStrand LSL 4 1 4
ACCESSORIES LIST
Plot Unit 1 of Net
ID Length Product Qty Plies Qty
Bbl 1' 1/2" or 5/8" Backer Blocks 6 1 6
Wb1 8 5/8" 1/2" x 2 5/16" Web Stiffeners 7 2 14
Rml 17' 6" 1 1/4" x 11 7/8" 1.3E TimberStrand LSL 12 1 12
Eb 7' 9" 11 7/8" TJI /Pro -150 Blocking Panels 1 1 1
Bkl 1' 2 1/2" 11 7/8" TJI /Pro -150 Blocking Panels 28 1 28
Shl 4' x 8' 23/32" OSB 50 1 50
16"
J2
H
Rmr I ..I
H II J2 II
J 3 ID J3
k—�
II
.L , !1 H1 I;
01 :j
Rm
J2
2 J2
A oomplete TJ -Xpert framing plan includes th Trus Joist Builder's Guide or Pocket Guide
1.25"
JOB =TENTS
Randy Webb
Peterson 4 -Plex
LEVEL NOTES
File Name: Webb- Peterson.JOB
Level Name: Main Floor
Plot Date: 7/11/01 11:11
Design Date: 6/24/01 22:42
Drawing Scale: 1/8" - 1'
Job Status:
Foundation....Foundation
Main Floor....Plotted
6/24/01 22:42
Upper Floor... Plotted
Plotte 22:29
NOTE: Level design times indicated above
provide assurance for proper level
stacking. Upper levels must have earlier
design times.
Design Methodology: ASD
Floor Area Loading Is:
40 psf Live Load
12 psf Dead Load
Maximum Joist Deflection:
L/480 Live Load
L/240 Total Load
TJ -Pro Rating Information:
Weighted Average: 49
Lowest Rating: 40
Highest Rating: 55
Glued 6 Nailed Decking is Assumed
Direct Applied Ceiling is Assumed
Floor Decking: 23/32" OSB
Normal 0.C. Spacing = 16 "*
Default Wall / Beam Width:
Standard Blocking: Bkl*
TJ -Xpert 6.12 (1676) D
C6.12 06.12 S6.12 P6.12
*Unless noted otherwise
3.5 "*
HANGER LIST - Simpson Strong -Tie Company, Inc.®
Plot
ID Qty Product Label Top Nails Face Nails Member Nails Notes
H1 3 IUT29 8 -N10 2 -N10 (2)(5)
H2 4 IUT29 8 -N10 2 -N10 (2)
Hanger Notes:
( Web-Stiffeners Required
(5) Backer
J
M
H
u
Pc
Bk
Eb
V
O
SYMBOL LEGEND
TRUS JOIST
4 Tapert.
CREATED BY
BMC West
1425 North Holmes Ave.
P.O. Box 1831
IDAHO FALLS, ID 83401
208 - 522 -5571
FAX: 208 -529 -3610
TJI Joist Type
Rectangular Product Type
Bearing Wall
Beam
Hanger Type
Hanger Symbol
Parallel Closure Type
Blocking Type
Extra Blocking
(Lineal board length for panels
different from the O.C. spacing)
Point Load
Line Load
Area Load
Detail Callout Label
(See Builder's Guide or Pocket Guide)
Joist Layout Symbol
Wall Header / Bearing Width Warning
FOR THE TJ-XPERT WARRANTY
SEE BUILDER'S GUIDE OR POCKET GUIDE
Preliminary Layout
for Review and Approval