HomeMy WebLinkAboutAPPLICAITON & TRUSS - 02-00029 - L & L Legacy Apartments - RemodelBUIL
PERMIT APPLICA
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED
OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS.
OWNER L h O y
BUILDER r l 4 t
STRUCTURE: 0 NEW /
0 RESIDENCE
FOOTINGS
0 CONCRETE
0 MASONRY
0 OTHER
REMARKS:
0 COMM.
14 REMODEL
❑ EDUCATIONAL
FOUNDATION
O CONCRETE
O MASONRY
0 OTHER
BASEMENT
0 PARTIAL
0 FULL
0 NO
FLOORS
0 WOOD
0 CONCRETE
O OTHER
EXT. WALLS
0 WOOD
0 MASONRY
0 CONCRETE
0 VENEER
0 METAL
0 STUCCO
INT. WALLS
❑ WOOD
0 MASONRY
0 CONCRETE
0 DRYWALL
O PLASTER
0 TILE
CEILING
0 WOOD
O DRYWALL
0 PP ASTER
0 ACOUSTIC
0 OPEN
ROOF
HEAT
0 BUILT UP. ()GAS
0 WOOD SH. 0 OIL
rgit'COMP. SH. 0 COAL
0 TILE 0 FIREPLACE
❑ ROLL ROOF. 0 ELECTRIC
0 METAL
This permit is issued subject to the regulations contained in the Uniform Building Code and Zoning Regulations of Rexburg, and it is hereby agreed
that the work to be done as shown in the plans and' specifications will be completed in accordance with the regulations
pertaining and applicable thereto: The issuance of the permit does not waive restrictive covenants.
DEPARTMENT OF BUILDING & ZONING
VALUE
FEE PAID
BUILDING
INSPECTOR
JOB ADDRESS
ARCHITECT
O ADDITION
0 GOVT 0 RELIGIOUS
0 REPAIR
0 FENCE 0 PATIO
,I 49/4 /f C4 No pj
WHITE-Owner's Copy CANARY - Building Department's Copy PINK
REXBURG, ID DATE
PHONE
DESIGNER
❑ RENEWAL
0 CARPORT
Copy GOLDENROD - Inspector
0 FIRE DAMAGE
0 GARAGE 0 AWNING
INSBLATED
cWALLS
OCEILING
0 FLOORS
O PERIMETER
16,
00 CASH
CH
APPLICANT
ADDRESS
APPLICATION FOR BUILDING PERMIT
C1TY OF REXBURG, IDAHO
Date of Application 77/ °°*1 Permit No. R- - 0 I°
OWNER
Name L 6 L � c
Site Address 027 � e 11(P iJ
Mailing Address
City /State /Zip �Q )1�,� , T,Q
Telephone/Fax/Mobile
CONTRACTOR
Name 10--/ ifei
Mailing Address 01 1 /J� f &-rGL
City /State /Zip y a Jet,
Telephone/Fax/Mobile
PROJECT INFORMATION DEPARTMENT APPROVAL
Property Zone: GO IMAA Is existing use compatible with zoning, (screening parking, etc)
Cv1'l ✓
When was this building last occupied
Architect/ Engineer Firm
Subdivision
Plan Name
Lot Block
Circle One Residenti Commercial Educational Government Remodel Other
Circle One New House
Circle One Basement: None/ Finished / Unfinished
Lot Square Footage Lot Width
Square Feet Garage Square Feet Number of Stories Height of Building
What will structure be used for: Home Home Business Apartme Commercial) Other
Will there be an apartment?
Total Estimated Cost 1 10 cj Are you in a flood plain
Signature of Applicant
Building Permit Fees 0
Plan Check Fees
Code /9 ?? &R 6--
Zone C gi
Building Type V /V
Addition/Remodel to House New Commercial
C C ercial Remode
Other: None/ Patio/ Carport/ Awning N/A
If so, how many units
Plumbing Permit Fees
Digging Permit Fees
Water & Sewer Fees
Front Footage Fee
TOTAL $
Signature of Inspector '
Issued by
Job
Truss
Truss Type
Qty
Ply
06004 -02
A2
QUEENPOST
12
1
(optional)
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
LOADING (psf)
TCLL 35.0
TCDL 8.0
BCLL 0.0
BCDL 8.0
-2 -0 -0
2 -0 -0
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.6E
BOT CHORD 2 X 4 SPF 1650F 1.6E
WEBS 2 X 4 SPF Stud /Std
BRACING
TOP CHORD
Sheathed or 5 -3 -8 oc purins.
BOT CHORD
Rigid ceiling directly applied or 9 -4 -1 oc bracing.
REACTIONS (Ib /size)
B = 1061/0 -5-8 F 1061/0-5-8
Max Horz
B = 15(load case 5)
Max Uplift
B = - 453(load case 5) F = - 453(load case 6)
Max Grav
B = 1183(load case 2) F = 1183(load case 3)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 27 B-C = -1785 C -D = -1319
D-E = -1319 E -F = -1785 F -G = 27
BOT CHORD
B -H = 1682 F -H = 1682
WEBS
C-H = -468 D-H = 501 E -H = -468
5 -0 -9
5 -0 -9
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code UBC97 /ANSI95
8 -8 -8
8 -8 -8
LOAD CASE(S)
Standard
CSI
TC 0.72
BC 0.61
WB 0.30
8 -8 -8
3 -7 -15
4x4 =
D
NOTES
1) This truss has been designed for the wind loads generated by 80 mph
winds at 25 ft above ground level, using 7.0 psf top chord dead load and 7.0
psf bottom chord dead load, 100 mi from hurricane oceanline, on an
occupancy category I, condition I enclosed building, of dimensions 45 ft by 24
ft with exposure C ASCE 7 -93 per UBC97 /ANSI95 If end verticals exist, they
are not exposed to wind. If cantilevers exist, they are exposed to wind. If
porches exist, they are exposed to wind. The lumber DOL increase is 1.33,
and the plate grip increase is 1.33
2) Design load is based on 35.0 psf specified roof snow load.
3) Unbalanced snow loads have been considered for this design.
4) Overhang has been design for 2.00 times live load + dead load.
5) This truss has been designed for a 10.0 psf bottom chord live load
nonconcurrent with any other live loads per Table No. 16-3, UBC -97.
6) Provide mechanical connection (by others) of truss to bearing plate
capable of withstanding 453 Ib uplift at joint B and 453 Ib uplift at joint F.
7) This truss has been designed with ANSI/TPI 1 -1995 criteria.
12 -4 -7
3 -7 -15
DEFL in (loc) Vdefl
Vert(LL) -0.12 B-H >999
Vert(TL) -0.21 B-H >968
Horz(TL) 0.04 F n/a
1st LC LL Min Vdefl = 240
17 -5 -0
8 -8 -8
PLATES
MI120
4.201 SR1 s Nov 16 2000 MiTek Industries, Inc. Tue Jun 04 10:04:03 2002 Page 1
Weight: 58 Ib
17 -5 -0
5 -0 -9
GRIP
197/144
19 -5 -0
2 -0 -0
scale = 1:25.8
Job
06004 -02
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
LOADING (psf)
TCLL 35.0
TCDL 8.0
BCLL 0.0
BCDL 8.0
354
Truss
Al
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.6E
BOT CHORD 2 X 4 SPF 1650F 1.6E
OTHERS 2 X 4 SPF Stud/Std
BRACING
TOP CHORD
Sheathed or 6 -0 -0 oc puriins.
BOT CHORD
Rigid ceiling directly applied or 10-0 -0 oc bracing.
REACTIONS (lb /size)
A = 165/17 -5 -0 G
J = 190/17 -5 -0 K
= 398/17 -5-0 1
H = 398/17 -5 -0
Max Horz
A = - 11(load case 6)
Max Uplift
A = - 13(load case 5) G
K = - 28(load case 5) L
1 = - 28(load case 6) H
Max Gray
A = 191(load case 2) G
J = 190(load case 1) K
L = 466(Ioad case 2) 1
H = 466(load case 3)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 51
- 165/17 -5 -0
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr NO
Code UBC97 /ANSI95
145/17 -5-0
145/17 -5 -0
= - 14(load case 6)
_ - 57(load case 5)
▪ - 57(load case 6)
= 191(load case 3)
= 171(load case 2)
= 171(load case 3)
Truss Type
ROOF TRUSS
8 -8 -8
8 -8 -8
1.554 II
CSI
TC 0.30
BC 0.10
WB 0.10
(Matrix)
1.554 II
TOP CHORD
B-C = -54 C -D = -40 D-E = -40
E -F = -54 F -G = -43
BOT CHORD
A -L = 10 K -L = 10 J -K = 10
I -J = 10 H -I = 10 G-H = 10
WEBS
D-J = -150 C -K = -128 B-L = -334
E -I = -128 F -H = -334
NOTES
1) This truss has been designed for the wind loads generated by 80 mph
winds at 25 ft above ground level, using 7.0 psf lop chord dead load and 7.0
psf bottom chord dead load, 100 mi from hurricane oceanline, on an
occupancy category I, condition I enclosed building, of dimensions 45 ft by 24
ft with exposure C ASCE 7 -93 per UBC97 /ANSI95 If end verticals exist, they
are not exposed to wind. If cantilevers exist, they are exposed to wind. If
porches exist, they are exposed to wind. The lumber DOL increase is 1.33,
and the plate grip increase is 1.33
2) Truss designed for wind loads in the plane of the truss only. For studs
exposed to wind (normal to the face), see MiTek "Standard Gable End Detail"
3) Gable requires continuous bottom chord bearing.
4) Gable studs spaced at 2 -0-0 00.
5) This truss has been designed fora 10.0 psf bottom chord live load
nonconcurrent with any other live loads per Table No. 16-B, UBC -97.
6) Provide mechanical connection (by others) of truss to bearing plate
capable of withstanding 13 Ib uplift at joint A, 14 Ib uplift at joint G, 281b uplift
at joint K, 57 Ib uplift at joint L, 28 Ib uplift at joint I and 57 Ib uplift at joint H.
7) This truss has been designed with ANSI/TPI 1 -1995 criteria.
454 =
1.554 II
17 -5 -0
17 -5 -0
Qty
1
DEFL in (loc) I /deft
Vert(LL) n/a - n/a
Vert(TL) n/a - n/a
Horz(TL) 0.00 G n/a
1st LC LL Min Vdefl = 240
LOAD CASE(S)
Standard
Ply
1.5x4 II
(optional)
1.554 II
PLATES
M1120
4.201 SR1 s Nov 16 2000 MiTek Industries, Inc. Tue Jun 04 10:04:02 2002 Page 1
17 -5 -0
8 -8 -8
Weight: 48 Ib
GRIP
197/144
354
Scale = 1:20.8
a
ct