Loading...
HomeMy WebLinkAboutCO & DOCS - 02-00023 - BYUI Smith Bldg - Paint Shop RemodelCERTIFICATE OF OCCUPANCY City of Rexburg Department of Building Inspection Building Permit No: R o - o5 - 15 Applicable edition of code: ❑ International Building Code 2000 ❑ International Residential Code 2000 ❑ Uniform Building Code 1997 Site address: 525 South Center Street Use and occupancy: Commercial Type of construction: Design occupant load: Sprinkler System required: ❑ Yes ❑ No Name and address of owner: BYU -Idaho 525 South Center Street Rexburg, Idaho 83440 Contractor: BYU -Idaho Special conditions: Occupancy: ❑ Full ❑ Partial ❑ Temporary This Certificate, issued pursuant to tbe requirements of Section 109 of the International Building Code, certifies that, at the time of issuance, this building or that portion of the building that was inspected on tbe date listed was fame to he in compliance with the requirements of the code for the group and division of occupancy and the use for which the proposed occupancN was c(assi f ied. Date: November 21, 2003 s AM C.O. Issued by: Water Department Building Official There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and approved said future changes. Fire Department State of Idaho Electrical Department - (208 - 356 -483o) ❑ Merlin Webster DEPARTMENT OF BUILDING & ZONING VALUE FEE PAID 0CHECK BUILDING INSPECTOR WHITE - Owner's Copy CANARY — Building Department's Copy PINK — Assessor's Copy GOLDENROD- Inspector APPLICANT ADDRESS • BUILDING PERMIT APPLICATION REXBURG, ID DATE THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. JOB ADDRESS f, r\ 4.1r " w I ARCHITECT ; ; -'j . I t.3,4 ( t 0 OWNER ' t , ` 1 LAF4 0 BUILDER t1 t' . 1 YEA (-+ STRUCTURE: EE 0 NEW I REMODEL p ADDITION 0 REPAIR O RESIDENCE 0 COMM. ,EDUCATIONAL 0 GOVT p RELIGIOUS p FENCE p PATIO FOOTINGS FOUNDATION BASEMENT FLOORS EXr. WALLS INT. WALLS CEIUNG O CONCRETE 0 MASONRY 0 OTHER 0 WOOD O CONCRETE CI OTHER O WOOD 0 MASONRY 0 CENEER O METAL O STUCCO U MASON CONCRETE t.9�Q O PLASTER O TILE OD R O P ± R O TIC pF PHONE 6• NO R /12.-61 DESIGNER 0 RENEWAL p FIRE DAMAGE O CARPORT 0 GARAGE p AWNING ROOF HEAT INSULATED ❑CONCRETE ❑ PARTIAL CI MASONRY CI FULL O BUILT UP. 1S CI WALLS ❑ W OOD SH O OIL O CEILING O OTHER p NO O COMP. SH. O COAL O FLOORS O TILE 0 FIREPLACE p PERIMETER O ROLL ROOF. p ELECTRIC O METAL This permit is issued subject to the regulations contained in the Uniform Building Code and Zaning Regulations of Rexburg, and itiai er that the work to be done as shown in the plans and specifications will be completed in accordance w the re ulations pertaining and applicable thereto: The issuance of the permit does not waive restrictive covena s.�"` REMARKS: Date of Application 4-( OWNER Name t/j av A' -{-O Site Address t -A ) 11-V9 113 CT Mailing Address A Ti City /State /Zip Telephone/Fax/Mobile'( �, ' 2 j fo CONTRACTOR Name Ej q — 1 0A /1 Mailing Address City /State/Zip Telephone/Fax/Mobile PROJECT INFORMATION Property Zone: Signature of Applicant Code /91-7 aige-- APPLICATION FOR BUILDING PERMIT CITY OF REXBURG, IDAHO Signature of Inspector Poem SHOP DEPARTMENT APPROVAL existing use compatible with zoning, (screening parking, etc) When was this building last occupied (.."—C) 00Z 4-<--t_(..( Architect/ Engineer Firm F)( 4 4 — t 9A4 -Q Plan Name Subdivision or /...,,cs/ Lot Circle One Residential Commercial (1~ducational.) Government Remodel Other What will structure be used for: Home Home Business Apartment ommercial they Will there be an apa ent? If so, how many units Total Estimated Co 3 , 00717 you in a flood plain Permit No. - 6 5 I Block TOTAL $ 57f - ss Circle One New House Addition/Remodel to House New Commercial Canmercial Rem el Circle One Basement: Finished / Unfinished Other: I�Qn` Patio/ Carport/ Awning N/A Lot Square Footage Lot Width Square Feet 2 1 CO Garage Square Feet Number of Stories Height of Building Building Permit Fees ,' 712 55 Zone Plan Check Fees / y7• e a Building Type Plumbing Permit Fees Digging Permit Fees Water & Sewer Fees Issued by Excava :ion & F� - t hwcrk Concrete: Masonry: Roofing: Insulation: Drywall: ( J Y tN ..42___ Painting: f Floor Coverings: P l umb ing : Hewing Electrical: ()\J 42 Roof Trusses: SUBCONTRACTOR LTST SPECIAL CONSTRUCTION (MANUFACTURER OR SUPPLIER) F Floor / Cai1i Joists: Cabinets: S iQ- nQ /E:i'L sr i0r 'T'r i_p : Fax # (208) 359 -3022 To: Rulon Neilsen Fax: 496 -2490 Pages: 5 including this cover Phone: Date: 4/30/2002 Re: Jaelemeiliget CC: City of Rexburg From: Val Christensen ❑ Urgent x For Review ❑ Please Comment 0 Please Reply Q Please Recycle • Comments: Rulon, the Fire Department is still waiting for more information on the Smith Building and the Paint Booth Projects. I have included copies of the Fire Department review. Please let me know if I can be of any assistance. Val MEMO: TO: TO WHOM IT MAY CONCERN FROM: CHRIS HUSKINSON, FIRE MARSHAL DATE: APRIL 27, 2002 RE: BYU -I SMITH BUILDING, THIRD FLOOR TO WHOM IT MAY CONCERN: Upon review of the site plan drawings submitted the following items need to be addressed: 1. Alarm drawings show both hom/strobe and strobe units to be used. At a meeting on 3/13/02 with Lloyd Bensen of BYU -I we agreed to delete the strobes and replace all with horn/strobe units. Please provide updated drawings. If there are any questions please feel free to contact me. Chris Huskinson Fire Marshal MEMO: TO: TO WHOM IT MAY CONCERN FROM: CHRIS HUSKINSON, FIRE MARSHAL DATE: APRIL 27, 2002 RE: BYU -I PAINT SHOP, PHYSICAL PLANT TO WHOM IT MAY CONCERN: Upon review of the site plan drawings submitted the following items need to be addressed: 1. These plans were originally reviewed February 16, 2002 where I requested additional information to be submitted. The new plans do not provide any additional information. Please provide items requested, original review attached. If there are any questions please feel free to contact me. Chris Huskinson Fire Marshal REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box 280 26 North Center Rexburg, Idaho 83440 (208) 359 -3010 1997 Uniform Fire Code Plan Date: 02 -02 Plan Review Review Date: 02 -16 -02 Building Name: BYU -I PAINT SHOP, PHYSICAL PLANT Building Address: BYU -I CAMPUS Stories: ONE Type of Construction: BLOCK Occupancy Classification: H -3 Existing Floor Area: APPR. 320 SQ. FT. New Construction Floor Area: N/A 1).Requir.ed Fire Flow (Appendix III -A): 1,500 GPM (FOR THIS PORTION OF THE BUILDING ONLY) 2).Water Supply (Article 9, Section 903) Required: Yes Fire Hydrant Location: C -42, C -45 Water Supply Acceptable: Yes Fire Hydrant Location Acceptable: Yes 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES 4),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable: NOT SHOWN Type Provided Acceptable: NOT SHOWN Comments: MINIMUM 0,0F 40B WITHIN 30 FEET 5).Automatic Fire Extinguishing Systems: (Article 10 Section 1003 Required: YES 6).Standpipes (Article 10 Section 1004) Required: - 7).Fire Alarm Systems (Article 10 Section 1007)Required: YES, DEPENDING UP THE TOTAL NUMBER OF SPRINKLER HEADS IN THE SYSTEM. PLEASE SUBMIT A DESCRIPTION OF ENTIRE SPRINKLER SYSTEM AND ALARM SYSTEM. Plans As Submitted Are Acceptable: NO COMMENTS: SPRAY BOOTH MUST MEET THE REQUIREMENTS SET FORTH IN THE 1997 UFC SECTION 4502 (SEE ATTACHED). FIRE SPRINKLER SYSTEM SHALL ALSO BE INSTALLED. AS PER 1999 NFPA 13. SPRINKLER SYSTEM SHALL ALSO BE TESTED TO NFPA STANDARDS UPON COMPLETION. ADDITIONAL ITEMS SUCH AS FIRE ALARM SYSTEM MAY NEED TO BE INSTALLED OR MODIFIED AND TESTED DEPENDING ON WHAT IS CURRENTLY IN PLACE. ALARM SYSTEM SUBMITALS MAY ALSO BE REQUIRED. PLEASE SUBMIT FIRE SPRINKLER PLANS, ALARM PLANS, ETC. Plans Checked By: CHRIS HUSKINSON Date: 2 - 16 - 02 REXBURG MADISON COUNTY FIRE DEPARTMENT P.O. Box 280 26 North Center Rexburg, Idaho 83440 (208) 359 -3010 1997 Uniform Fire Code Plan Date: 02 -02 Plan Review Review Date: 02 -16 -02 Building Name: BYU -I PAINT SHOP, PHYSICAL PLANT Building Address: BYU -I CAMPUS Stories: ONE Type of Construction: BLOCK Occupancy Classification: H -3 Existing Floor Area: APPR. 320 SQ. FT. New Construction Floor Area: N/A 1).Required Fire Flow (Appendix III -A): 1,500 GPM (FOR THIS PORTION OF THE BUILDING ONLY) 2).Water Supply (Article 9, Section 903) Required: Yes Fire Hydrant Location: C -42, C -45 Water Supply Acceptable: Yes Fire Hydrant Location Acceptable: Yes 3.)Fire Apparatus Access Roads (Article 9 Section 902) Required: YES 4),Installation Of Portable Fire Extinguisher (Article 10 Section 1002) Required: YES Location Acceptable: NOT SHOWN Type Provided Acceptable: NOT SHOWN Comments: MINIMUM OF 40B WITHIN 30 FEET 5).Automatic Fire Extinguishing Systems: (Article 10 Section 1003 Required: YES 6).Standpipes (Article 10 Section 1004) Required: NO 7).Fire Alarm Systems (Article 10 Section 1007)Required: YES, DEPENDING UP THE TOTAL NUMBER OF SPRINKLER HEADS IN THE SYSTEM. PLEASE SUBMIT A DESCRIPTION OF ENTIRE SPRINKLER SYSTEM AND ALARM SYSTEM. Plans As Submitted Are Acceptable: NO COMMENTS: SPRAY BOOTH MUST MEET THE REQUIREMENTS SET FORTH IN THE 1997 UFC SECTION 4502 (SEE ATTACHED). FIRE SPRINKLER SYSTEM SHALL ALSO BE INSTALLED AS PER 1999 NFPA 13. SPRINKLER SYSTEM SHALL ALSO BE TESTED TO NFPA STANDARDS UPON COMPLETION. ADDITIONAL ITEMS SUCH AS FIRE ALARM SYSTEM MAY NEED TO BE INSTALLED OR MODIFIED AND TESTED DEPENDING ON WHAT IS CURRENTLY IN PLACE. ALARM SYSTEM SUBMITALS MAY ALSO BE REQUIRED. PLEASE SUBMIT FIRE SPRINKLER PLANS, ALARM PLANS, ETC. Plans Checked By: CHRIS HUSKINSON Date: 2 -16 -02 Hs EXISTING PAINT BOOTH Hs NOTE 2 Hs PAINT SHOP STORAGE 0 7 NOTE 3 NOTE 5, TYP OF 4 TOOLS (n WORK SURFACE APPROVED tu 0 BUILDING INSPECTOR ABBREVIATIONS: 115- HAZARDOUS STORAGE CABINt1 R- REFRIGERATOR 5- SINK DEMOLITION NOTES: I. REFRIGERATOR TO BE RELOCATED 2. HS CABINETS $ WORK BENCHES TO BE RELOCATED 3. REMOVE PAINT CAN STORAGE RACKS $ SHELVING ON WEST HALF OF SOUTH WALL. SAVE FOR REINSTALLATION. PATCH $ REPAIR HOLES IN BLOCK. 4. EXISTING COMPRESSED AIR OUTLET TO REMAIN; PROTECT DURING CONSTRUCTION. 5. REMOVE EXISTING OUTLETS $ WIRES; INSTALL BLANK COVER PLATES 6. MODIFY VENTILATION DUCTWORK (5EE SHEET A2 -2) EXISTING I`LOOK PLAN DEMOLITION SCALE: 1/8" = I ' -0" REVISIONS: PROJECT #: PPLT -0 I 0 SHEET AI - I HS NOTE 9 NOTE 5 NOV Olt 1 EXISTING PAINT BOOTH HS i H NOTE 2 ♦ . NC(� .I► 1 ;; i ` . ._ 1 1 0' -4" FACE OF \x/ • I STUD TO FACE OF BLOCK / `\ k\ NOTE i ! �0 23' -7 "± NOTE 9 NOTE 2 i - NOTE 5 NOTE 4, TYP OF 4 NOTE 5 STORAGE PAINT SHOP NOTE 6 FINISHED OPENING TO BE 6' -OW x 7-0H EXIST. WOOD COLUMN NOTE I I TOOLS WORK SURFACE NOTE 7 Jc/ 1\1 /r Co 5 z (f) REMODEL PLAN SCALE: 1/8" = I ' -0" CONSTRUCTION NOTES: I . ASSEMBLE $ POSITION NEW PAINT BOOTH BEFORE BUILDING WALLS (ORDER FROM JBI. MODEL IDB- 108 [OR EQUAL]) 2. BUILD NEW WALLS (SEE DETAILS ON SHEET A4 -I) 3. FRAME CEILING. (SEE DETAILS ON SHEET A2 -2) 4. INSTALL I I OV OUTLETS @ 4' AFF. POSITION AS SHOWN THIS SHEET 5. EXTEND EXIST. FIRE SPRINKLER LINES. PROVIDE HEADS IN BOOTH ROOM, BOOTH, IN DUCT ABOVE BOOTH, $ IN PAINT STORAGE ROOM. QUALIFIED OUTSIDE CONTRACTOR TO PROVIDE APPROVED SHOP DRAWINGS $ PERFORM WORK G. BUILD $ INSTALL 6'- Ox7' -O SLIDING DOOR. (SEE DETAILS ON SHEET A4 -2) HANG W/ HEAVY -DUTY SLIDING DOOR HARDWARE, OBTAINABLE @ C -A -L STORE 7. REPOSITION WORKBENCHES $ HAZARDOUS STORAGE CABINETS 8. REINSTALL 6 EA 8' -LONG PAINT RACKS TO WALL. CUT LENGTH DOWN TO MT AVAILABLE SPACE, IF NEEDED. ATTACH TO EACH STUD W/ LAGS. POSITION FIRST RACK @ 18" AFF W/ OTHERS @ 14" ABOVE THE ONE BELOW 9. REINSTALL SHELVING IN CLOSET TO HOLD PAINT INVENTORY. CUT SHELF LENGTH TO MT IN ROOM. MOUNT DOUBLE SHELF STANDARD ON EA. STUD. INSTALL FIRST SHELF @ 18" AFF. SPACE OTHER SHELVES @ 1 2" ABOVE THE ONE BELOW 10. PAINT ALL NEW WALLS, CEILING, DECK, $ DOORS TO MATCH EXIST. REPAINT BLOCK WALLS INSIDE NEW BOOTH I I . PROVIDE NEW COMPRESSED AIR OUTLET AS PER NOTE ON SHEET M- I REVISIONS: Ln Ln z z a- -Oa_ r co Q Q (s) z Q L cn 1 PROJECT #: PPLT -O 10 SHEET A2- 1 HS NOTE E2 HS NOTE E l EXISTING PAINT BOOTH HS PAINT BOOTH EXHAUST SYSTEM DEMO $ REMODEL SCALE: 1/8" = I ' -0" NOTES: E I . REMOVE VERTICAL DUCTWORK IN AREA SHOWN SHADED. CUT BACK* CAP TRUNK LINE FLUSH W/ NEXT VERTICAL DUCT. E2. INSTALL NEW VERTICAL DUCT CENTERED BETWEEN TWO REMAINING VERTICALS. EXTEND TOWARD FLOOR AS FAR AS PRACTICAL W /OUT INTERFERING W/ EXISTING CABINETRY (SEE MECHANICAL DRAWINGS) C I . FRAME CEILING W/ 2x8s @ 24" OC. PROVIDE OPENINGS FOR LIGHT BOXES * DUCTWORK. PROVIDE OPENINGS IN CEILING TO SERVICE SPRAY BOOTH LIGHTS FROM ABOVE C2. INSTALL * SWITCH LIGHTS AS SHOWN. (SEE DETAIL ON SHEET A4 -1) SWITCH LIGHTS IN SPRAY BOOTH W/ OTHER LIGHTS IN ROOM 14' -9" _ N U) _ HS EXISTING PAINT BOOTH H HS 23' -7" NOTE C I I'_5' CEILING FRAMING PLAN $ REFLECTED CEILING PLAN SCALE: 1/8" = 1 I' -5" TYP FRAMED LIGHT BOX @ 222' x 522'. BOX TO RECEIVE 4 -TUBE FLOUR - ESCENT FIXTURE. SEE LIGHTS IN EXIST. PAINT BOOTH FOR MOUNTING METHOD REVISIONS: PROJECT #: PPLT -0 1 0 SHEET A2 -2 JOISTS ATTACHED TO LEDGER BOARD W/ STD. JOIST HANGERS 2 "x8" LEDGER BOARD FASTENED TO HALL W/ 3/8"0 X 4 -3/8 HILTI HIT HY20 SYS EM FASTENERS @ 2' -0 C.C. EXISTING CMU WALL SCALE: 1" = 1 ' -O" 1 4' -9' WALL SECTION OSB DECKING 2 "x8" CEILING JOIST @ 24" OC RIM JOIST --\\ TYPE X GYP BD. TAPE, TEXTURE, t PAINT 2 "x4" STUD @ i 6" OC TYPE X GYP BD, FIRE -TAPED $ COVERED WI AC PLYWOOD 2 "x4" SOLE PLATE. ANCHOR TO FLOOR W/ HILT' ANCHORS @ "OC TRIM BOARD 2 EA. 2 "x4" CAP PLATES e' TYPE X GYP BD, FIRE -TAPED $ COVERED W/ AC PLYWOOD FINISH FLOOR 55" 12" PLAN VIEW OF TUBULAR FRAME e' OSB DECKING 2x8 CEILING JOISTS @ 24" OC e' TYPE X GYP BD — 1 " TUBULAR STEEL FRAME WI 22 GA SHEET METAL ATTACHED TO BOTTOM, SINGED FOR CHANGING LIGHTS. PROVIDE THIN FOAM WEATHERSTRIP ALL AROUND PERIMETER TO SEAL OUT DUST wVir q'x2" STOP 2' 4" 4 -TUBE FL LT FIXTURE 4' WIRED GLAZI HINGE, WELDED TO TUBING PAINT ALL SURFACES INSIDE LIGHT BOXES BRIGHT WHITE TRIM BOARD /GLASS STOP I " SQUARE STEEL TUBING, SCREWED TO DECKING LIGhT 50X SECTION SCALE: 3" = 1' -O" REVISIONS: PROJECT #: PPLT -O I 0 SHEET A4- I G'-4" 4" 4" I '_ 7' DOOR ELEVATION SCALE: I " = 1' -0" 2" 20"± x 20 " ±. BUILD EXACT SIZE TO FIT FILTER GRIDS M CH COME W/ PAINT BOOTH DOOR DETAIL SCALE: 3" = 1 - DOOR DETAIL SCALE: 3" = I' -O" ALL PIECES FROM q' MDF ALL PIECES FROM MDF REVISIONS: PROJECT #: PPLT -0I0 SHEET A4 -2 OSB DECKING 2 CEILING JOISTS @ 24" OC EXTRA FRAMING AS NEEDED 9' -O FROM FLOOR PAINT BOOTH CEILING 8'-0 FROM FLOOR 2" ED DETAIL @ TOP OF BOOTH SCALE: 3" = I' -O" Go y a' GYP BD I 0 8' CONT CALK BEAD ALL AROUND FRONT OF BOOTH EXIST. INSULATION EXIST. ROOF DECK 8" MIN. DETAIL @ I Of 15OOTt1 SCALE: 3" = I' -O" 2 "x8" ALL AROUND OPENING STUDS @ G" O.C. OPENING SIZED TO FIT EQUIPMENT NEW 2 "x 12" CURB 3" PLATED GRABBER @ 12" O.C. 2 ROWS PLATED GRABBER SCREWS @ 3" O.C. , STAGGERED NOTE: 2 PENETRATIONS RQD. ADDITIONAL STUDS @ FRONT OF BOOTH FLASH OVER TOP OF CURB TYP ROOF PENETRATION DETAIL SCALE: 1- I /2" = 1 '-0" BALLASTED EPDM kb. ROOF MEMBRANE. PATCH $ REPAIR BY QUALIFIED ROOFER 4 „Ar, CANT STRIP SHEETROCK BUTTED AGAINST BOOTH FRONT CONT CALK BEAD ALL AROUND FRONT OF BOOTH FRONT EDGE OF PAINT BOOTH JAMB SIDE REVISIONS: 'u^! L 1 CU Q- 0 a__ 0 0 � r < cs) < (r) 1� y o (f) a 1 PROJECT #: PPLT -O I O SHEET A4 -3 EQUIPMENT .IST SYMBOL DESGR`-'TION EXHAUST FAN - FURNISHED NTH PA 1 BOOTH PROVIDED BY OWNER AND INSTALLED BY GONTRAGTOR. :., H.P. MOTOR (208/60/3) WITH IOp00 GFM AT 1.0" EXTERNAL STATIC PRESSURE. INSTALL 24"4) FAN IN EXHAUST DUET 'THRU ROOF k.:D r'?NNEGT TO HOOD CONTROLS THRU VFD. PAINT BOOTH - JBI MODEL I0B -121 9RY ARRESTOR SPRAY BOOTH COMPLETE WITH 21"4 EXHAUST FAN �i2 tip, 208/60/3), (2) LIGHT FIXTURES AND FILTER BANK. HOOD'; 'TO BE T -0" HIGH x 12' -0" WIDE x 1 WORKING DEEPTH INSIDE WORK.INS AREA, MADE FROM GALVANIZED SHEET METAL. PROVIDED BY OWNER AND INSTALLED BY GONTRAGTOR. SUPPLY FAN - PENN MODEL MU602O WITH LOUVERED SIDES, FILTERS, 11,250 GFM AT b3" EXTERNAL STATIC: PRESSURE, 1-I/2 H.P., 208/60/3, AND 610 RPM MOTOR. CONTROL THF!J VFD. i HOT WATER HEATING GOIL - WING IFB --F -60 COIL WITH 82.0 GPM, 180 °F ENTERING WATER TEMPERATI, I60 °F LEAVING WATER TEMPERATURE, -10°F ENTERING AIR, ,jam lq °F TEMPERATURE RISE. COIL TO HAVE A MINIMUM OF 1262 43TU GAPAGITY WITH 450 FPM FAGE VELOGITY. REFER TO COIL PIPING DETAIL FOR GONNEGTIONS. COIL TO BE 60" LONG, 62" HIGH WITH 2 ROW. i 0 EXISTING AIR HANDLER AND DUCTWORK TO REMAIN IN OPERATION. PROTECT DURING CONSTRUCTION. 0 DISCONNECT AND REMOVE EXISTING 30x30 MAKE -UP AIR DUCT FROM NEAR GEILING AND ABOVE EXISTING PAINT BOOTH. O EXISTING ROOF -TOP EXHAUST FAN TO REMAIN. DISCONNECT FROM EXISTING DUCTWORK. REMOVE EXISTING DUCTWORK (SEE NOTE 4). INSTALL NEW PRIGE MODEL 535, SIZE 30x30 EXHAUST GRILLE AT GEILING AND CONNECT TO EXISTING ROOF -TOP EXHAUST FAN. MAKE TRANSITION AS REQUIRED TO GONNEGT GRILLE WITH EXISTING DUGTWDRK. 4O DISCONNEGT AND REMOVE EXISTING EXHAUST DUCT AND BRAGKETS ON WALL. PATCH HOLES IN WALL TO MATGH ADJACENT SURFACES. O EXISTING HOT WATER UNIT HEATER TO REMAIN. PROTECT DURING GONSTRUGTION. O NEW OWNER PROVIDED PAINT BOOTH COMPLETE WITH EXHAUST FAN, ARRESTOR PADS, AND SHEET METAL HOOD CONSTRUCTION. INSTALL EXHAUST FAN WHERE SHOWN. RISE 24 "4) EXHAUST DUCT UP THRU ROOF. REFER TO DETAIL - THIS SHEET. O MOUNT NEW SUPPLY FAN ON EXISTING ROOF WITH NEW ROOF CURB. GUT EXISTING TONGUE AND GROOVE ROOF DEGKING AS REQUIRED TO DROP 24x24 DUCT DOWN INTO ROOM. REFER TO SUPPLY FAN DETAIL - THI5 SHEET. GORRDINATE LOCATION WITH EXISTING PIPING, LIGHTING AND STRUCTURE. O INSTALL NEW HOT WATER COIL AS SPEGIFIED NEAR GEILING AND GONNEGT TO ROOF -TOP SUPPLY FAN. TRANSITION 24x24 DUCT AS REQUIRED TO FIT NEW COIL. GONNEGT 2 -1/2" HOT WATER SUPPLY AND RETURN LINES TO EXISTING HOT WATER PIPING AND TO NEW COIL. REFER TO DETAIL - THIS CI IEET FOR CONNECTIONS. O INSTALL NEW CONTROLLER AND DISG AIR SENSOR. INTERLOCK WITH NEW ROOF TOP SUPPLY FAN AND HOT WATER FADE AND BYA55 COIL. CONTROLLER TO GONTROL DISCHARGE AIR TEMPERATURE OF MAKE -UP 10 EXISTING VFD'S ON WALL TO REMAIN. PROTECT DURING CONSTRUCTION. II NEW VFD'S FOR NEW EXHAUST FAN AND SUPPLY FAN ON ROOF. 12 EXISTING HOOD CONTROLS TO REMAIN. PROTECT DURING CONSTRUCTION. 13 EXTEND EXISTING FIRE SPRINKLER PIPING THRU NEW GEILING WITH REGESSED HEADS. 14 INSTALL (q) 20 "x20 "x2" FILTER RACKS WITH HIGH GAPAGITY FILTERS ON EAGH DOUR. 0 CONNECT NEW 3/4" AIR LINE TO EXISTING AIR PIPING. VERIFY ACTUAL LOCATION AND SIZE OF EXISTING LINE. INSTALL SOLENOID VALVE PROVIDED WITH PAINT BOOTH AND INTERLOGK WITH BOOTH GONTROL PANEL. DRVN. BY: M JENSEN 00128 CKD. BY: D SUDWEEKS FEB. '02 LOUVERED PANEL SIDES NEOPRENE GASKET ROOF CURB ROOF DECKING REMOVABLE ROOF GAP POWERED PENTHOUS !TAIL NO SCALE GUY WIRE PLATE WITH I /2" HOLE -� I/4" PLATE -� go 2 "4) SGHEDULE�k'IPE I/4" BOLT 6" MIN. - ,I` - OFFICE 21 AIR DUCT EXHAUST DUCT `J GAULK WITH ELASTOMERIG SEALANT �-- DRAWBAND WATER -TIGHT UMBRELLA STAINLESS 24 GA. RIGID INSULATION WITH PVG ROOFING 4" WOOD DEGKING PLATE 12 "x12 "xl /4" MOTOR CHINA GAP z MECHANICAL 1 20 1 0 I" THICK FILTERS (REMOVABLE) BLOWER HOUSING MOUNTING BASE 2 "4' SGHEDULE 80 PIPE SINGLE PLY ROOFING PATCH BY GERTIFIED ROOFING CONTRACTOR I /2 "4) BOLTS 4 PLACES - 0 L, 12" TYP. 4 SIDES ti ❑ 1/2" TYP. TOOLS 1 la HWR HVv T?IGAL uY WIRE ATTACHMENT DETAIL NO 5GALE I /4 "x5" GUSSET 4 PLACES TOOLS 1 is MANUAL AIR VENT 54S GIRGUIT SETTER. SET AT 82 GPM7 BALL VALVE -a ■ ELECTRICAL 11 GONNEGT PIPING TO MAIN LINES \ 6, HOT WATER SUPPLY PIPING HOT WATER RETURN PIPING I /4" STEEL PLATE SEAL ROOF PENETRATION WEATHER -TIGHT TO MATCH EXISTING ROOF BY CERTIFIED ROOFING CONTRACTOR. 0 TERMINATE EXHAUST DUGT 6' -0" MIN. ABOVE ROOF -\ ROOF -\ TYPICAL UNION OFFICE 16 DAMPER MOTOR. INTERLOCK WITH THERMOSTAT CONTROLLER ININ6 FACE AND BYPASS HOT WATER COIL PIPING DIAGRAM NO SCALE 24 "4) CHINA GAP GUYWIRE SEE DETAIL PAINT ROOM r FLOOR AIR CONDITIONING 14 EXHAUST FAN AND DUCT DETAIL NO xALE n� ABOVE BOOTH EXISTING FIRE SPRINKLER PIPING. VERIFY EXACT LOCATION. 0 L NEW FILTER BANK WITH REMOVABLE FILTERS AGRO55 ENTIRE GROSS SECTION OF BOOTH r L EXISTING 2 -1/2" HWS r PAINTING 13 2 -1/2" )1 Ogg AS poi O J A -3/4" �' EXISTING 4" HWR L. SCALE: I /8" = 1' -0" PAINTING 12 J TOOLS C [1 F LOOR PLAN - MECHANICAL CARPENTRY d UPHOLSTERY ❑ ❑ PHYSICAL PLANT STORES 2 OFFIGE 5 lJ L r EQUIP. 5YM EQUIPMENT NAME MOTOR BREAKER OR DISCONNECT CIRCUIT I - ttDER REMARKS AMPS. VOLTS 4' H.P. K.W. EXHAUST FAN 10.6 208 3 3 - 60A NEMA 3R FUSED 5-1 - SEE PLAN - - 0 Adak SUPPLY FAN 24.2 208 3 15 6OA NEMA 3R FUSED S-I - SEE RAN - 0 DR14Td. BY: M -ENSEN 00128 CKD. BY: D SUDWEEKS FEB. '02 OFFICE 21 L .J MECHANICAL 20 TOOLS Iq TOOLS I8 NEGHANIGAL EQUIPMENT LOAD SCHEDULE ELECTRICAL 11 OFFICE 16 FLOOR PLAN - LC.TSICAL SGALE: I /S" = I' -0'• OFFICE 15 L1] WA GATALO& TYPE Fl F2 DESCRIPTION MAIVAGTRER .BF -DAY BRIGHT LITHONIA LIGHT FIXTURE SCHEDULE LB-232 FLUSH MOUNT MOMTIN5 SURFACE WRAP LAP'S 4- F32T8 -SPX35 2- F32T8 -5PX35 REMARKS LIGHT FIXTURE SUPPLIED BY OWNER LAMPS AND INSTALLATION BY ELECTRICIAN. WIRE INTERLOCK SWITCHES WITH AIR SOLENOID JA ilTY LT5 REG MI5 5F -I EF -I SPARE SPARE SPARE SPADE GAP 10,000 AMPS PANEL „5 VOLT SE 120/208V 30 TYPE "50 D" NQOD SCHEDULE S .G. I NOTES: NT. GIR tro 3 5 1 q II 13 15 11 Iq 21 23 25 21 2q 31 33 35 3 3q 41 LOAD BREAKER WATTS p.e Amp 3100 3 3100 3100 1000 3 1000 1000 - 3 20 - 3 30 60 30 20 LOCATION PAINT ROOM MAIN 225 AMP LUGS ❑ BREAKER LOAD/POLE A 11 B 11 G 1 BREAKER Pag Ate 1 3600 1 2500 I 1500 1 1000 ( 1 3600 2500 1500 3600 I 2500 I 50 600 1 50 20 20 20 IS FAD BOTTOM ❑ FEED TOP DIMENSIONS 20" x LOAD GAR WATTS NO 2500 2 2500 4 2500 6 1500 6 1500 10 1500 12 1500 14 I500 16 1500 l8 1000 20 500 22 600 24 28 - 32 ❑ FLUSH SURFACE x 5 3/4" SCHEDULE EXISTING EXISTING EXISTING EXISTING LIGHTS - PANT 1300TH RECEV1AGLES ROOF RECEPTACLES SPACE TOTAL WA t t 5 8600 8100 8200 FEEDER: BRKR. SIZE 225 A TOTAL AMPS 12 68 68 CONDUIT 2 1/2" CONDUCTORS 4 - #4/O QUANT11Y 4 3 SPARE AIR CONDITIONING 14 r_,! .. NEW PANEL "5" PAINTING 13 1 10 r- 0 ORTH 0 7 1 12 TOOLS i TOOLS 11 [1 LUMBER STORAGE 4 STAIRS CARPENTRY d UPHOLSTERY I s CJ OFFICE PHYSICAL PLANT STORES 2 L r r r - T L C J O EXISTING AIR HANDLER AND DUCTWORK TO REMAIN IN OPERATION. PROTECT DURING CONSTRUCTION. 0 EXISTING ROOF -TOP EXHAUST FAN TO REMAIN. EXISTING HOT WATER UNIT HEATER TO REMAIN. PROTECT DURING CONSTRUCTION. 0 INSTALL NEW PAINT HOOD CONTROLS WITH EXHAUST FAN, ARRESTOR PADS, AND LIGHT FIXTURES. O REPLACE EXISTING FI FGTRIGAL PANEL WITH NEW. RUN 444/0 IN 2 -1/2" CONDUIT TO EXISTING PANEL "M ". PROVIDE AND INSTALL NEW 225 AMP, 3 POLE BEAKER IN PANEL "M ". TIE EXISTING LOADS FROM OLD PANEL INTO NEW. PROVIDE TYPEWRI tN INDEX SHEET IN NEW PANEL. O RUN 08, 3/4 "G TO NEW 30 AMP, 3 POLE BREAKER IN NEW PANEL "5". RUN 446 I "G FROM VFD TO HEAVY DUTY NEMA 3R DISCONNECT AT EXHAUST FAN ON ROOF. O RUN 4 I "G TO NEW 60 AMP, 3 POLE BREAKER IN NEW PANEL "5 ". PROVIDE HEAVY DUTY NEMA 3R DISCONNECT AT FAN ON ROOF. RUN 4#4, I I /2 "G FROM VFD TO SUPPLY FAN ON ROOF. TIE INTO HOOD CONTROLS THRU VFD. O EXISTING VFD'S ON WALL TO REMAIN. PROTECT DURING CONSTRUCTION. O NEW VFD'S FOR NEW EXHAUST FAN AND SUPPLY FAN ON ROOF. PROVIDED BY MECHANICAL- INSTALLED AND CONNECTED BY FI FGTRIGAL. Cps EXISTING HOOD CONTROLS TO REMAIN. PROTECT DURING CONSTRUCTION. it EXISTING LIGHT FIXTURES d SWITCHES TO REMAIN. PROTECT DURING CONSTRUCTION. RELOCATE EXISTING FIXTURE LOCATION AS NEEDED TO ACCOMMODATE NEW WALLS. 12 NEW THERMOSTAT AND PRESSURE CONTROL BY MECHANICAL. WIRE AND INTERLOCK WITH 5F -1, HEATING VALVE AND DAMPER MOTOR BY ELECTRICIAN. 13 REMOVE EXISTING CONVENIENCE OUTLET, PULL WIRING BACK TO SOURCE, AND GAP. INSURE DOWNSTREAM CIRCUITS TO REMAIN IN USE. NEW HOOD CONTROL PANEL SUPPLIED WITH HOOD CONNECT TO NEW LIGHTING AND FANS. REFER TO MFG INSTRUCTIONS. 20A GFGI RECEPTACLE WITH WEATHER PROOF COVER ON ROOF. INTERLOCK SOLENOID VALVE WITH FAN OPERATION l ND LIGHT FIXTURE INTERLOCKS. MOUNT NEW RECEPTACLES AT 48 ". VERIFY LOCATION WITH OWNER. Cr Y H5 EXISTING PAINT BOOTH hS NOTE 2 FAINT SHOP u 0 NOTE 2 STORAGE NOTE/ - NOTE 5, TYF OF 4 TOOLS (r) tri 0 0 O 0 z WORK 5UKFACE DEPT PLAN APPROvED DiSAPPRErirr' C-4 L 0.7 WASTE WATER PLUMBII'4G ELECTRICAL o o ENGINEER MECHANICAL Ej D PUB. WKS O BLG. OFF O O OTHER ABBREVIATIONS: 115— HAZARDOUS STORAGE CABINET R— REFRIGERATOR 5— SINK DEMOLITION NOTES: 1 . REFRIGERATOR TO BE RELOCATED 2. I CABINETS $ WORK BENCHES TO BE RELOCATED 3. REMOVE FAINT CAN STORAGE RACKS $ SHELVING ON WEST HALF OF SOUTH WALL. SAVE FOR REINSTALLATION. PATCH $ REPAIR HOLES IN BLOCK. 4. EXISTING COMPRESSED AIR. OUTLET TO REMAIN; PROTECT DURING CONSTRUCTION. 5. REMOVE EXISTING OUTLETS WIRES; INSTALL BLANK COVER PLATES 6. MODIFY VENTILATION DUCTWORK (5EE SHEET A2-2) EXISTING PLOOK PLAN DEMOLITION SCALE: I /8" = 1 1 -0" 0 d REVISIONS: Lc) LC) c\I z 0 0 r co 7 <t t n < (r) z < O--- a__ n PROJECT #: PPLT-0 1 0 SHEET Al— I NOTE 9 NOTE 5 4' L r NS NOTE 2 9 \ X • . \ I / 1 ``\ I i . `1 EXISTING PAINT BOOTH hS NOTE 2 HS 0 1 �I.# ■ I I 0-4" FACE OF :STUD TO FACE OF BLOCK • 1 • �- NOTE 5 NOTE 4, TYP OF 4 NOTE 5 23' - 7 "' NOTE I NOTE 8 D NOTE 2 STORAGE TOOLS PAINT SHOP NOTE G FINISHED OPENING TO BE G-OW x 7' -OH EXIST. WOOD COLUMN NOTE I I Jc/ Co " °` WORK SURFACE (f ) REMODEL PLAN SCALE: 1/8" = l'-0" CONSTRUCTION NOTES: 1. ASSEMBLE $ POSITION NEW PAINT BOOTH BEFORE BUILDING WALLS (ORDER FROM J. MODEL IDB- 108 [OR EQUAL]) 2. BUILD NEW WALLS (SEE DETAILS ON SHEET A4-1) 3. FRAME CEILING. (SEE DETAILS ON SHEET A2 -2) 4. INSTALL 1 I OV OUTLETS @ 4' AFF. POSITION AS SHOWN THIS SHEET 5. EXTEND EXIST. FIRE SPRINKLER LINES. PROVIDE HEADS IN BOOTH ROOM, BOOTH, IN DUCT ABOVE BOOTH, $ IN PAINT STORAGE ROOM. QUALIFIED OUTSIDE CONTRACTOR TO PROVIDE APPROVED SHOP DRAWINGS $ PERFORM WORK 6. BUILD $ INSTALL 6'- 0x7' -0 SLIDING DOOR. (SEE DETAILS ON SHEET A4 -2) HANG W/ HEAVY -DUTY SLIDING DOOR HARDWARE, OBTAINABLE @ C -A -L STORE 7. REPOSITION WORKBENCHES $ HAZARDOUS STORAGE CABINt I S 8. REINSTALL 6 EA 8' -LONG FAINT RACKS TO WALL. CUT LENGTH DOWN TO FIT AVAILABLE SPACE, IF NEEDED. ATTACH TO EACH STUD W/ LAGS. POSITION FIRST RACK @ 18" AFF W/ OTHERS @ 14" ABOVE THE ONE BELOW 9. REINSTALL SHELVING IN CLOStI TO HOLD PAINT INVENTORY. CUT SHELF LENGTH TO FIT IN ROOM. MOUNT DOUBLE SHELF STANDARD ON EA. STUD. INSTALL FIRST SHELF @ 18" AFF. SPACE OTHER SHELVES @ 1 2" ABOVE THE ONE BELOW 10. PAINT ALL NEW WALLS, CEILING, DECK, DOORS TO MATCH EXIST. REPAINT BLOCK WALLS INSIDE NEW BOOTH I I . PROVIDE NEW COMPRESSED AIR OUTLET AS PER NOTE ON SHEET M -1 REVISIONS: C0 z m o tu < cZ • U w a_ 0_ PROJECT #: PPLT -010 SHEET A2-1 _ • _ HS NOTE E2 EXISTING PAINT BOOTH H NOTE E l HS PAINT BOOTH EXHAUST SYSTEM DEM SCALE: 1 /8" = 1 ' -0" 0 O$REIV NOTES: ODEL E 1 . REMOVE VERTICAL DUCTWORK IN AREA SHOWN SHADED. CUT BACK* CAP TRUNK LINE FLUSH W/ NEXT VERTICAL DUCT. E2. INSTALL NEW VERTICAL DUCT CENTERED BETWEEN TWO REMAINING VERTICALS. EXTEND TOWARD FLOOR AS FAR AS PRACTICAL W /OUT INTERFERING W/ EXISTING CABINETRY (SEE MECHANICAL DRAWINGS) C I . FRAME CEILING W/ 2x8s @ 24" OC. PROVIDE OPENINGS FOR LIGHT BOXES # DUCTWORK. PROVIDE OPENINGS IN CEILING TO SERVICE SPRAY BOOTH LIGHTS FROM ABOVE C2. INSTALL $ SWITCH LIGHTS AS SHOWN. (SEE DETAIL ON SHEET A4- I ) SWITCH LIGHTS IN SPRAY BOOTH WI OTHER LIGHTS IN ROOM /0 (j (( c,v 14'-9 HS 11 EXISTING PAINT BOOTH H 23' -7" HS NOTE C '_5" CEILING FRAMING PLAN $ REFLECTED CEILING PLAN SCALE: I /8" = 1 ' -0" I' -5" TYP FRAMED LIGHT BOX @ 222' x 522'. BOX TO RECEIVE 4 -TUBE FLOUR - ESCENT PIXI URE. SEE LIGHTS IN EXIST. PAINT BOOTH FOR MOUNTING METHOD REVISIONS: 1 PROJECT #: PPLT -010 SHEET A2 -2 JOISTS ATTACHED TO LEDGER BOARD W/ STD. JOIST HANGERS 2 "x8" LEDGER BOARD FASTENED TO NALL 3/00 X 4-3/0 HILT! HIT HY20 SYS - EM FASTENERS @ 2' -0 C EXISTING CMU WALL 14 9" C. SCALE: I " = I ' -O" WALL SECTION , ' 055 DECKING - 2 "x8" CEILING JOIST @ 24" OC RIM JOIST TRIM BOARD if TYPE X GYP BD. TAPE, TEXTURE, $ PAINT 2 "x4" STUD @ 1 G" OC TYPE X GYP BD, FIRE -TAPED $ COVERED W/ AC PLYWOOD 2 "x4" SOLE PLATE. ANCHOR TO FLOOR W/ HILT! ANCHORS @ 36" OC 2 EA. 2 "x4" CAP PLATES g' TYPE X GYP BD, FIRE -TAPED $ COVERED W/ e' AC PLYWOOD FINISH FLOOR 55" OS B DECKING 2x8 CEILING JOISTS @ 24" OC if TYPE X GYP BD 4\ 4' cie 2" 12" PLAN VIEW OF TUBULAR FRAME I" TUBULAR STEEL FRAME WI 22 GA SHEET METAL ATTACHED TO BOTTOM, HINGED FOR CHANGING LIGHTS. PROVIDE TH IN FOAM WEATHERSTRIP ALL AROUND PERIMETER TO SEAL OUT DUST 2 -4" 4', 4 -TUBE FL LT FIXTURE HINGE, WELDED TO TUBING I" SQUARE STEEL TUBING, SCREWED TO DECKING ( Ad 11 1 m , 4'x2" STOP WIRED GLAZING Pi r 4 a & L A 1 PAINT ALL SURFACES INSIDE LIGHT BOXES BRIGHT WHITE TRIM BOARD /GLASS STOP LIGHT 50X SECTION SCALE: 3" = I ' -0" REVISIONS: CD z m o � 1-1 U w�= IL 1 PROJECT #: PFLT -O I 0 SHEET A4- I G' -4" 4" 1 7' DOOR ELEVATION SCALE: 1 = 1 -O 4" 2" 20"± x 20 " BUILD EXACT SIZE TO FIT FILTER GRIDS NMICh COME W/ PAINT BOOTH 0 J DOOR DETAIL SCALE: 3 DOOR DETAIL SCALE: 3" = I' -O" ALL PIECES FROM in MDF ALL PIECES FROM MDF REVISIONS: m 0 o 1C U CL LIJ 1-� a_ Pa 1 PROJECT #: PPLT -O I 0 SHEET A4 -2 1 05B DECKING 2,0 CEILING JOISTS @ 24' 00 9' -0 FROM FLOOR EXTRA FRAMING AS NEEDED PAINT BOOTH CEILING rt _ 8' -O FROM FLOOR 2" DETAIL @ TOP Of 500Th SCALE: 3" = I' -0" Go y GYP BD 10 g' CONT CALK BEAD ALL AROUND FRONT OF BOOTH l . � EXIST. INSULATION EXIST. ROOF DECK 2 "x8" ALL AROUND OPENING 8" MIN STUDS @ 1 0" O.C. OPENING SIZED TO FIT EQUIPMENT C E DETAIL @ I Of BOOTH SCALE: 3" = I' -O" NEW 2 "x 12" CURB ADDITIONAL STUDS @ FRONT OF BOOTH FLASH OVER TOP OF CURB ' � EMI! 3" PLATED GRABBER 2 ROWS PLATED GRABBER SCREWS @ 3" O.C., STAGGERED NOTE: 2 PENETRATIONS RQD. TYP ROOF PENETRATION DETAIL SCALE: I - I /2" = I' -0" CANT STRIP BALLASTED EPDM ROOF MEMBRANE. PATCH & REPAIR BY QUALIFIED ROOFER SHEETROCK BUTTED AGAINST BOOTH FRONT CONT CALK BEAD ALL AROUND FRONT OF BOOTH FRONT EDGE OF PAINT BOOTH JAMB SIDE REVISIONS: PROJECT #: PPLT -OI0 SHEET A4 -3