HomeMy WebLinkAboutCO & DOCS - 02-00065 - Bowen Student Housing - RemodelCERTIFICATE OF OCCUPANCY
City of Rexburg
Department of Building Inspection
Building Permit No. R- o2 -o9 -19
Building Street Address: 174 South 3 West
Building Owner: David Bowen
Contractor: Shaw Homes and Constructions
Description of building or portion of building for which this certificate is
issued:
Commercial - Remodel
Occupancy:
This Certificate, issued pursuant to the requirements of Section 1o9 of tbe Uniform Buif ding
Code, certifies that, at the time of issuance, this builbin9 or that portion of tbe builain@ that
was inspected on the bate f istea was f ouna to be in compliance with the requirements of the
cote for the group and division of occupancy and tbe use for which the propose occupancy
was classified.
C.O. Issued by:
Building Official
There shall be no future change in the existing occupancy classification of the building nor shall
any structural changes, modifications or additions be made to the building or any portion thereof
until the Buildi Official has reviewed and approved said future changes.
Water Department ,e -,Fire Department
State of Idaho Electrical Department - (208 - 356-4830) ❑
Full
BUILDING PERMIT APPLICATION REXBURG, ID DATE
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED
OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS.
OWNER
BUILDER ,.I`
STRUCTURE: p NEW 0 REMODEL
0 RESIDENCE
FOOTINGS
Ca'CONCRETE
0 MASONRY
O OTHER
REMARKS:
0 COMM.
❑ EDUCATIONAL
DEPARTMENT OF BUILDING & ZONING
VALUE 3 5 lJ
FEE PAID /
BUILDING
INSPECTOR
JOB ADDRESS / a
ARCHITECT
0 ADDITION
0 REPAIR
PHONE
DESIGNER
❑ RENEWAL
0 GOVT p REUGIOUS p FENCE p PATIO p CARPORT
This permit is issued subject to the regulations contained in the Uniform Building Code and Zoning Regulations of Re
that the work to be done as shown in the plans and specifications will be completed in accordance with tt regulati
pertaining and applicable thereto: The issuance of the permit does not waive restrictive covenants.
p CASH APPUCANT
OO CHECK
DATE .ADDR
WHITE — Owner's Copy CANARY — Building Department's Copy PINK — Assessor's Copy GOLDENROD- Inspector
0 GARAGE p AWNING
FOUNDATION
CONCRETE
O MASONRY
O OTHER
BASEMENT
0 PARTIAL
0 FULL
ONO
FLOORS
£ION D
RETE
0 OTHER
EXT. WALLS
0 WOOD
O MASONRY
OS, ER
NEER
O METAL
0 STUCCO
INT. WALLS CEIUNG ROOF
0 WOOD
0 MASONRY
OILIQPNCRETE
irDRYWALL
O PLASTER
0 TILE
0 WOOD
p''GRYWALL
❑ PLAST R
O TILE
p ACOUSTIC
O OPEN
CI BUILT UP.
0 WOOD SH.
(AMP. SH.
0 TILE
CI ROLL ROOF.
0 METAL
HEAT
OIraAS OIL
CI COAL
CI FIREPLACE
0 ELECTRIC
NO.��'7
0 FIRE DAMAGE
SEP 2 " 200'?
INSULATED •,,
CitWALLS
O CEILING
CI FLOORS
❑ PERIMETER'
Q reby agr
Date of Application / ° .23 -0 2-
OWNER
Name .en, /3 an/ 4
Site Address / 75'
Mailing Address 4r 1 t 3 — S -
APPLICATION FOR BUILDING PERMIT
CITY OF IIEXBURG, IDAHO
.14/ 'L/ "''�
City /State /Zip
Telephone/Fax/Mobile /- o— 9 7 f3 2 3
CONTRACTOR
Name
Mailing Address
City /State /Zip j ,
Telephone/Fax/Mobile 6 - 9/SS
PROJECT INFORMATION DEPARTMENT APPROVAL
te s e .175,
Property Zone: Is existing use compatible with zoning, (screening parking, etc)
When was this building last occupied
Architect/ Engineer Firm
Subdivision
Circle One Residen Commercial Educational Government Remodel Other
Circle One New House dditionemodel to House New Commercial Commercial Remodel
Circle One Basement on Finished / Unfinished Other: None/ Patio/ Carport/ Awning N/A
Lot Square Footage , - ( Lot Width
5
Square Feet 7(/j Garage Square Feet NA Number of Stories ( Height of Building
What will structure be used for: Ho e
Will there be an apartment ?
Total Estimated Cost 3S . 0
Signature of Applicant
Zone
* **** ** **** *** *** * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * *
Code
Building Type
Home BusinesapartmeD Commercial Other
If so, how many units
Are you in a flood plain
CC-
Plan Name
Lot
Buildii Permit Fees
° LCP% Plan Chck Fees
Permit No. f O t-o 9 —19
Block
plumbing P F ees �l' a)
`Digging Permit Fees
Water & Sewer Fees
Front Footage Fee
TOTAL $ s
Signature of Inspector
Issued by J \ )
Rough Plumbing
Septic Tank
Fixtures
Water Piping
Complete
Sewer
Bath Tubs
Urinal
Showers
Sink Trap
Laundry Trays
Water Heater
Wash Basin
f
Other
Toilet
/
Slop Sinks
Kitchen Sinks
,r
Floor Drain
Drinking Fountains
Lawn Sprinklers
Water Softeners
Dish Washing Mach.
/
Clothes Washer
Name
Address .' M . °` ~' Tel
CITY OF REXBURG
APPLICATION FOR PLUMBING PERMIT
OWNER FEES
Lot Blk. Add.
PLUMBER
Name
Address Tel.
NATURE OF INSTALLATION
Use
DESCRIPTION OF WORK
Plumbing Permit
Sewer Inspection $
Inspection of Pipe $
Inspection of Fixtures $
TOTAL $
Received: Date
By
INSPECTOR'S RECORD
N
P A! .
SEP 2 ` 2002
Rough Plumbing
Sewer
Other
Finish Plumbing
INSP. NAME
Masonry: D n `.
Roofing:�
ins�latio�i : d,1�
Drywall:
` wcrJ: / L' aJ/l E a r tiri o '1
a- ncre to : o - c L eoGL .
Painting:
Floor Ccvar.incs:
Plumbing:
a
Electrical:
Roof Trutaes:
'�i
'? oc=: / calling Joista :
e 7
irne_c
nds
UJ O ; A CTOR LTST
SPECIAL CONSTRUCTION
(MANUFACTURER OR SUPPLIER)
nf)6, tiAtai _
1
Job
10021 -02
Truss
B1GD
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
Truss Type
KINGPOST
8 -4 -8
8 -4 -8
8 -4 -8
8 -4 -8
Plate Offsets(X,Y): [A:1 - 5 - 11, Edge],[ A: 0 - 10-10, Edge],[ A: 0- 5- 8,1- ast[A:0- 5- 7,1- 5- 91,[C:1- 5-11,0 -0-01 [C:0- 10- 10,Edg5]
LOADING (psf)
TCLL 35.0
TCDL 7.0
BCLL 0.0
BCDL 7.0
LUMBER
TOP CHORD 2 X 6 LSL Truss Grade
BOT CHORD 1.5 X 9.5 LSL Truss Grade
WEBS 2 X 4 SPF 1650F 1.6E
BRACING
TOP CHORD
Sheathed.
BOT CHORD
Rigid ceiling directly applied or 4 -6-4 oc bracing.
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr NO
Code UBC97 /ANSI95
REACTIONS (Ib /size)
A = 4999/0 -5 -8 C
Max Horz
A = 12(load case 5)
Max Uplift
A = - 2003(load case 5) C = - 2021(load case 6)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = -10143 B -C = -10143
BOT CHORD
A -E = 9675 E -F = 9675 F -G = 9875 G -H
D -H = 9675 D -I = 9675 I -J = 9875 J -K = 9675
K -L = 9675 C -L = 9675
WEBS
B -D = 4884
NOTES
1) This truss has been designed for the wind loads generated by 80 mph winds at
25 ft above ground level, using 7.0 psf top chord dead load and 7.0 psf bottom
chord dead load, 100 mi from hurricane oceanline, on an occupancy category!,
condition 1 enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE
7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
Cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
2) Design load is based on 35.0 psf specified roof snow bad.
3) Unbalanced snow loads have been considered for this design.
CSI
TC 0.69
BC 0.87
WB 0.76
(Matrix)
= -84.0 B -C = -84.0
4) Overhang has been design for 2.00 times live load + dead load.
5) This truss has been designed for a 10.0 psf bottom chord live load
nonconcurrent with any other live loads per Table No. 16-B, UBC -97.
6) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 2003 Ib uplift at joint A and 2021 Ib uplift at joint C.
7) This truss has been designed with ANSI/TPI 1 -1995 criteria.
8) Use USP THD26 (With 164 nails into Girder NASD nails into Truss) or
equivalent spaced at 2 -0-0 oc max. starting at t -5 -4 from the left end to 15 -5 -4 to
connect truss(es) Al (1 ply 2 X 4 SPF) to back face of bottom chord.
9) Fill all nail holes where hanger is in contact with lumber.
10) Special hangers) or connection(s) required to support concentrated bad(s)
147.51b down and 8.lIb up at 0-2 -12 on bottom chord. Design for unspecified
4914 /0-5 -8 connection(s) is delegated to the building designer.
LOAD CASE(S)
Standard
1) Snow: Lumber Increase =1.15, Plate Increase =1.15
Uniform Loads (plf)
Vert:
A -C = -14.0 A -B
Concentrated Loads (Ib)
Vert: A= -147.5 E =- 1021.1 F =- 1021.1 G =- 1021.1 H =- 1021.1 1 =- 1021.1
= 9675 J =- 1021.1 K=- 1021.1 L =- 1021.1
Oty
DEFL in (lox) Vdefl
Vert(LL) -0.32 C -D >609
Vert(TL) -0.45 C -D >436
Horz(TL) 0.08 C rile
1st LC LL Min Vdefl = 240
Ply
1
SHAW CONST. - TRIPLEX
optional)
PLATES
M1120
16 -9 -0
8 -4 -8
Weight: 114 Ib
4.201 SR1 s Nov 16 2000 MiTek Industries, Inc. Tue Oct 15 18:18:12 2002 Page 1
16 -9 -0
8 -4 -8
GRIP
197/144
Scale = 1:19 :
"Job
10021 -02
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
Plate Offsets (X,Y)jJE:0- 2- 0,Edge
LOADING (psi)
TCLL 35.0
TCDL 7.0
BCLL 0.0
BCDL 7.0
Truss
AIG
5 -4 -8
5 -4 -8
7-6-0
7 -6 -0
SPACING 2 -0-0
Plates increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code UBC97 /ANSI95
Truss Type
ROOF TRUSS
Z iii eiii •••••ii ii iii
10 -9 -0
5 -4 -8
CSI
TC 0.26
BC 0.08
WB 0.10
(Matrix)
LUMBER BOT CHORD
TOP CHORD 2 X 4 SPF 1650F 1.6E L -M = 8 K -L = 8 J -K = 8 I -J = 8
BOT CHORD 2 X 4 SPF 1650F 1.8E WEBS
OTHERS 2 X 4 SPF Stud /Std E -N = -124 0 -0 = -205 C -P = -95 B -Q = -332
F -M = -205 G -K = -95 H -J = -332
BRACING
TOP CHORD NOTES
Sheathed or 6-0-0 oc purlins. 1) This truss has been designed for the wind lads generated by 80 mph winds
BOT CHORD at 25 ft above ground level, using 7.0 psf top chord dead load and 7.0 psf bottom
Rigid ceiling directly applied or 10 -0-0 oc bracing. chord dead load, 100 mi from hurricane oceanline, on an occupancy category I,
condition I enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE
REACTIONS (Ib /size) 7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
A = 157/21 -6 -0 I = 157/21 -8 -0 cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
L = 17/21 -6-0 N = 152/21 -6 -0 wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
O = 236/21 -6 -0 P = 111/21 -6 -0 2) Truss designed for wind loads in the plane of the truss only. For studs
Q = 388/21 -6 -0 M = 229/21 -6-0 exposed to wind (normal to the face), see MiTek "Standard Gable End Detail"
K = 99/21 -6 -0 J = 390/21 -6-0 3) Gable requires continuous bottom chord bearing.
Max Horz 4) Gable studs spaced at 2 -0 -0 oc.
A = - 16(load case 6) 5) This truss has been designed for a 10.0 psf bottom chord live load
Max Uplift nonconcurrent with any other live loads per Table No. 16-8, UBC -97.
A = - 11(load case 5) I = - 13(load case 6) 6) Provide mechanical connection (by others) of truss to bearing plate capable of
O = - 41(load case 5) P = - 18(load case 5) withstanding 11 Ib uplift at joint A, 13 Ib uplift at joint I, 41 Ib uplift at joint 0, 18 Ib
O = - 61(Ioad case 5) M = - 47(load case 8) uplift at joint P, 61 Ib uplift at joint Cl, 47 Ib uplift at joint M, 31 Ib uplift at joint K
K = - 31(load case 6) J = - 60(load case 6) and 60 Ib uplift at joint J.
Max Gray 7) This truss has been designed with ANSI/TPI 1 -1995 criteria.
A = 184(load case 2) 1 = 184(load case 3)
L = 41(load case 4) N = 152(load case 1) LOAD CASE(S)
0 = 278(Ioad case 2) P = 132(load case 2) Standard
0 = 457(load case 2) M = 270(load case 3)
K = 119(load case 3) J = 459(load case 3)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 50 B -C = -50 C -D = 22 D -E = -39
E -F = -39 F -G = -23 G -H = -50 H -I = -38
BOT CHORD
A -Q = 8 P -Q = 8 O -P = 8 N -O = 8
M -N = 8
4x5 11
14 -0 -1
6 -6 -1
• DEFL in (loc) Vdefl
Vert(LL) n/a - n/a
Vert(TL) n/a - n/a
Horz(TL) 0.00 1 n/a
1st LC LL Min Vdefl = 240
Ply
1.5x4 11
16 -1 -9
5 -4 -8
SHAW CONST. - TRIPLEX
(optional)
4.201 SRI s Nov 162000 MiTek Industries, Inc. Tue Oct 15 18:18:102002 Page 1
3x4 a 1,5x4 I I 1.5x4 I I 1.5x4 I I 1.5x4 I I 1.504 I I 304 = 1.5x4 I I 1.5x4 I I
PLATES GRIP
• M1120 197/144
Weight: 62 Ib
21 -6 -0
7 -5 -15
21 -6 -0
5 -4 -7
Scale = 1.25..
Job
10021 -02
-2 -4 -0
2 -4 -0
Plate Offsets (X,Y): (H:0.4- 0,0 -3-0)_
LOADING (psf)
TCLL 35.0
TCDL 7.0
BCLL 0.0
BCDL 7.0
Truss
B1
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.6E
BOT CHORD 2 X 4 SPF 1650F 1.6E
WEBS 2 X 4 SPF Stud /Std
4 -8 -1
4 -8 -1
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code UBC97 /ANSI95
BRACING
TOP CHORD
Sheathed or 5 -4 -8 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 9-2 -13 oc bracing.
REACTIONS (Ib /size)
F = 1017/0 -5 -8 B = 1017/0 -5 -8
Max Horz
B = - 17(load case 6)
Max Uplift
F = - 463(load case 6) B = - 463(load case 5)
Max Gray
F = 1164(load case 3) B = 1164(bad case 2)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 29 B -C = -1751 C -D = -1273 D -E = -1273
E -F = -1751 F -G = 29
BOT CHORD
B -1-1 = 1658 F -H = 1658
WEBS
C -H = -473 D -H = 437 E -H = -473
NOTES
1) This truss has been designed for the wind bads generated by 80 mph winds at
25 ft above ground level, using 7.0 psf top chord dead bad and 7.0 psf bottom
chord dead load, 100 mi from hurricane oceanline, on an occupancy category I,
•condition I enclosed building, of dimensions 45 ft by 24 9 with exposure C ASCE
7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
2) Design load is based on 35.0 psf specified roof snow bad.
Truss Type
ROOF TRUSS
8 -4 -8
8 -4 -8
CSI
TC
BC
WB
0.94
0.53
0.26
8 -4 -8
3 -8 -8
3) Unbalanced snow loads have been considered for this design.
4) Overhang has been design for 2.00 times live load + dead load.
5) This truss has been designed for a 10.0 psf bottom chord live load
nonconcurrent with any other live loads per Table No. 16-9, UBC -97.
6) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 463 Ib uplift at joint F and 463 Ib uplift at joint B.
7) This truss has been designed with ANSI/TPI 1 -1995 criteria.
LOAD CASE(S)
Standard
4x4 =
0
Qty
3
12 -1 -0
3 -8 -8
DEFL in (loc) Vde6
Vert(LL) -0.09 B -H >999
Vert(TL) 0.18 A -B >175
Horz(TL) 0.04 F n/a
1st LC LL Min Vdefl = 240
Ply
SHAW CONST. - TRIPLEX
(optional)
16 -9 -0
8 -4 -8
PLATES
MI120
Weight: 57 Ib
4.201 SRI s Nov 162000 MiTek Industries, Inc. Tue Oct 15 18:18:10 2002 Page 1
16 -9 -0
4 -8 -1
GRIP
197/144
19 -1 -0
2 -4 -0
Scale - 1:25.1
Io
Job
10021 -02
LOADING (psf)
TCLL 35.0
TCDL 7.0
BOLL 0.0
BCDL 7.0
-2 -4 -0
2 -4 -0
Truss
B1A
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
LUMBER
TOP CHORD 2 X 4 DF 2400F 2.0E
BOT CHORD 2 X 8 OF 1800F 1.8E
WEBS 2 X 4 SPF Stud /Std'Except*
W1 2 X 4SPF 1650F 1.6E
BRACING
TOP CHORD
Sheathed or 2- 11 -15 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 8-5 -0 oc bracing.
REACTIONS (lb /size)
B = 2023/0 -5-8 F = 2015/0 -5 -8
Max Horz
B = - 17(load case 8)
Max Uplift
B = - 978(load case 5) F = - 974(load case 8)
Max Gray
B = 2199(load case 2) F = 2191(load case 3)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 85 B -C = -4850
E -F = -4820 F -G = 85
BOT CHORD
B -J = 4541 J -K = 4541
H -L = 4513 F -H = 4513
WEBS
C -J = -41 D -I = 2468
E -I = -288
C -D = -4511 D -E
I -K = 4541 I -L
E -H = -68 C -I
= -4511
= 4513
_ -320
NOTES
1) This truss has been designed for the wind loads generated by 80 mph winds at
25 ft above ground level, using 7.0 psf top chord dead load and 7.0 psf bottom
chord dead load, 100 mi from hurricane oceanline, on an occupancy category 1,
condition I enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE
7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
5 -4 -13
Truss Type
HOWE
5 -4 -13
5 -4 -13
5 -4 -13
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr NO
Code UBC97 /ANSI95
CSI
TC 0.89
BC 0.63
WB 0.38
(Matrix)
2 -11 -11
2 -11 -11
LOAD CASE(S)
Standard
1) Snow: Lumber Increase =1.15, Plate Increase =1.15
Uniform Loads (plf)
Vert:
B -F = -14.0 A -D = -84.0 D -G = -840
Concentrated Loads (Ib)
Vert: K=-1001.8 L=- 1001.6
8 -4 -8
8 -4 -8
4x5 11
D
2) Design load is based on 35.0 psf specified roof snow load.
3) Unbalanced snow bads have been considered for this design.
4) Overhang has been design for 2.00 times live bad + dead bad.
5) This truss has been designed for a 10.0 psf bottom chord live bad
nonconcurrent with any other live loads per Table No 16 -B, UBC -97.
6) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 978 Ib uplift at joint B and 974 Ib uplift at joint F.
7) This truss has been designed with ANSI/TPI 1 -1995 criteria.
8) Use USP HJC26 (With 18d nails into Girder 104 nails into Truss) or
equivalent spaced at 0 -8-4 oc max. starting at 8.0-6 from the left end to 8 -8-10 to
connect truss(es) J1 (1 ply 2 X 4 SPF), K1 HJ (1 ply 2 X 6 LSL), J1 (1 ply 2 X 4
SPF), K1HJ (1 ply 2 X 6 LSL) to front face of bottom chord.
9) Fill all nail holes where hanger is in contact with lumber.
K 1 L
10x10 =
HJC26 HJC26
Qty
11 -4 -3
11 -4 -3
2 -11 -11
DEFL in (loc) Vdeft
Vert(LL) 0.20 I -J >970
Vert(TL) -0.26 I -J >738
Horz(TL) 0.07 F rda
1st LC LL Min Vdefl = 240
Ply
SHAW CONST. - TRIPLEX
(optional)
PLATES
MI120
Weight: 79 Ib
4.201 SR1 s Nov 16 2000 MiTek Industries, Inc. Tue Oct 15 18:18:11 2002 Page 1
16 -9 -0
5 -4 -13
16 -9 -0
5 -4 -13
GRIP
197/144
19 -1 -0
2 -4 -0
Scale = 125.1
Job
10021 -02
Truss
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
LOADING (psf)
TCLL 35.0
TCDL 7.0
BCLL 0.0
BCDL 7.0
LUMBER
TOP CHORD 2 X 4 SPF 2100F 1.8E
BOT CHORD 2 X 4 SPF 1650F 1.8E
WEBS 2 X 4 SPF Stud /Std
BRACING
TOP CHORD
Sheathed or 8 -0-0 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10.0 -0 oc bracing.
REACTIONS (Ib /size)
D = 374/Mechanical B = 593/0 -5 -8
Max Holz
B = 145(load case 3)
Max Uplift
D = - 179(load case 3) B = - 273(load case 3)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 29 B -C = -0 C -D = -320
BOT CHORD
B -D = 0
-2 -4 -0
2 -4 -0
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress !nor YES
Code UBC97 /ANSI95
NOTES
1) This truss has been designed for the wind loads generated by 80 mph winds at
25 ft above ground level, using 7.0 psf top chord dead load and 7.0 psf bottom
chord dead load, 100 mi from hurricane oceanline, on an occupancy category 1,
condition I enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE
7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
2) Design load is based on 35.0 psf specified roof snow load.
3) Unbalanced snow loads have been considered for this design.
4) Overhang has been design for 2.00 times live bad + dead load.
5) This truss has been designed for a 10.0 psf bottom chord live load
nonconcurrent with any other live loads per Table No. 16-B, UBC-97.
6) Refer to girder(s) for truss to truss connections.
Truss Type
ROOF TRUSS
LOAD CASE(S)
Standard
CSI
TC 0.81
BC 0.38
WB 0.00
3.80 12
7) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 179 Ib uplift at joint D and 273 Ib uplift at joint B.
8) This truss has been designed with ANSITTPI 1 -1995 criteria.
Qty
2
8 =0 -0
8 -0 -0
B1
8-0-0
8 -0 -0
DEFL in (loc) Weft
Vert(LL) -0.19 B -D >470
Vert(TL) -0.21 8 -D >427
Horz(TL) 0.00 n/a
1st LC LL Min Udell = 240
Ply
SHAW CONST. - TRIPLEX
(optional)
PLATES GRIP
MI120 197/144
Weight: 24 Ib
4.201 SR1 s Nov 16 2000 MiTek Industries, Inc. Tue Oct 15 18:18:12 2002 Page 1
D
1.5x4 11
Wi
3x4 = 1.5x4 11
Scale = 1:17.
Job
10021 -02
LOADING (psf)
TCLL 35.0
TCDL 7.0
BCLL 0.0
BCDL 7.0
-2 -4 -0
2 -4 -0
Truss
Al
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.8E
BOT CHORD 2 X 4 SPF 1650F 1.0E
WEBS 2 X 4 SPF Stud /Std -
Plate Off ets 'i _jE_0 -0- 12,0 -1 -15] [G:0 -3.0 0-3 -0]
5 -4 -8
5 -4 -8
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code UBC97 /ANSI95
BRACING
TOP CHORD
Sheathed or 4-3 -2 oc purlins.
BOT CHORD
Rigid ceiling directly applied or 7-6-2 oc bracing.
REACTIONS (Ib /size)
F = 1035 /Mechanical B = 1254/0-5-8
Max Horz
B = 83(load case 5).
Max Uplift
F = - 435(load case 6) B = - 562(Ioad case 5)
Max Gray
F = 1035(load case 1) B = 1389(load case 2)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 29 B -C = -2427 C -D = -2019 D -E = -2030
E -F = -2449
BOT CHORD
B -H = 2300 0 -1-1 = 1571 F -G = 2324
WEBS
C -H = -466 D -H = 514 D -G = 529 E -G = -484
NOTES
1) This truss has been designed for the wind bads generated by 80 mph winds at
25 ft above ground level, using 7.0 psf top chord dead load and 7.0 psf bottom
chord dead load, 100 mi from hurricane oceanline, on an occupancy category I,
condition I enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE
7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
2) Design load is based on 35.0 psf specified roof snow bad.
Truss Type
ROOF TRUSS
7 -6 -0
CSI
TC
BC
WB
0.94
0.51
0.38
10 -9 -0
5 -4 -8
3) Unbalanced snow loads have been considered for this design.
4) Overhang has been design for 2.00 times live load + dead load.
5) This truss has been designed for a 10.0 psf bottom chord live bad
nonconcurrent with any other live loads per Table No. 18-B, UBC -97.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 435 Ib uplift at joint F and 562 Ib uplift at joint B.
8) This truss has been designed with ANSI/TPI 1 -1995 criteria.
LOAD CASE(S)
Standard
404
D
Qty
14 -0 -1
6 -6 -1
DEFL in (bc) gde8
Vert(LL) -0.15 G >999
Vert(TL) -0.24 G -H >999
Horz(TL) 0.06 F n/a
1st LC LL Min I /deg = 240
Ply
SHAW CONST. - TRIPLEX
(optional)
16 -1 -9
5 -4 -8
PLATES
MI120
Weight: 70 Ib
4.201 SR1 $ Nov 162000 MiTek Industries, Inc. Tue Oct 15 18:18:092002 Page 1
GRIP
197/144
21 -6 -0
7 -5 -15
21 -6 -0
5 -4 -7
Scale = 1:28:
I Job
10021 -02
Truss
J1A
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
LOADING (psf)
TCLL 35.0
TCDL 7.0
BCLL 0.0
BCDL 7.0
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code UBC97 /ANSI95
-2 -4 -0
2 -4 -0
ROOF TRUSS
LUMBER 5) This truss has been designed for a 10.0 psf bottom chord live load
TOP CHORD 2 X 4 SPF 1650F 1.6E nonconcurrent with any other live loads per Table No. 16 -B, UBC -97.
BOT CHORD 2 X 4 SPF 1650F 1.6E 6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 53 Ib uplift at joint C, 254 Ib uplift at joint B and 47 Ib uplift at joint D.
8) This truss has been designed with ANSI/TPI 1 -1995 criteria.
BRACING
TOP CHORD
Sheathed or 5 -11 -11 oc purlins.
BOT CHORD LOAD CASE(S)
Rigid ceiling directly applied or 10 -0-0 oc bracing. Standard
REACTIONS (Ib /size)
C = 180 /Mechanical B = 542/0 -5 -8
D = 39 /Mechanical
Max Horz
B = 115(load case 4)
Max Uplift
C = - 53(load case 4) B = - 254(load case 3)
D = - 47(load case 3)
Max Gray
C = 180(load case 1) B = 542(load case 1)
D = 95(load case 2)
FORCES (lb) - First Load Case Only
TOP CHORD
A -B = 59 B -C = 42
BOT CHORD
B -D = 0
NOTES
1) This truss has been designed for the wind loads generated by 80 mph winds at
25 ft above ground level, using 7.0 psf top chord dead load and 7.0 psf bottom
chord dead load, 100 mi from hurricane oceanline, on an occupancy category I,
condition 1 enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE
7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
2) Design load is based on 35.0 psf specified roof snow load.
3) Unbalanced snow loads have been considered for this design.
4) Overhang has been design for 2.00 times live load + dead load.
CSI
TC 0.52
BC 0.22
WB 0.00
(Matrix)
Qty
4
DEFL in (loc) I /deb
Vert(LL) 0.08 B -D >843
Vert(TL) 0.15 A -B >208
Horz(TL) -0.00 C n/a
1st LC LL Min 1/deft = 240
Ply
5 -11 -11
5 -11 -11
5 -11 -11
5 -11 -11
SHAW CONST. - TRIPLEX
(optional)
PLATES GRIP
M1120 197/144
Weight: 17 Ib
4.201 SR1 s Nov 16 2000 MiTek Industries, Inc. Tue Oct 15 18:18:12 2002 Page 1
Scale = 1:13.,
Job
10021 -02
LOADING (psf)
TCLL 35.0
TCDL 7.0
BCLL 0.0
BCDL 7.0
Truss
JIB
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code UBC97 /ANSI95
NOTES
1) This truss has been designed for the wind bads generated by 80 mph winds at
25 ft above ground level, using 7.0 psf top chord dead bad and 7.0 psf bottom
chord dead load, 100 mi from hurricane oceanline, on an occupancy category 1,
condition I enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE
7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
2) Design load is based on 35.0 psf specified roof snow load.
3) Unbalanced snow loads have been considered for this design.
4) Overhang has been design for 2.00 times live load + dead load.
Truss Type
ROOF TRUSS
-2 -4 -0
2 -4 -0
LUMBER 5) This truss has been designed for a 10.0 psf bottom chord live load
TOP CHORD 2 X 4 SPF 1650F 1.8E nonconcurrent with any other live loads per Table No. 16-B, UBC -97.
BOT CHORD 2 X 4 SPF 1650F 1.6E 6) Refer to girder(s) for truss to truss connections.
BRACING
TOP CHORD
Sheathed or 3 -11 -11 oc purlins.
BOT CHORD LOAD CASE(S)
Rigid ceiling directly applied or 10 -0 -0 oc bracing. Standard
REACTIONS (Ib /size)
C = 67 /Mechanical B = 473/0 -5 -8
D = 25 /Mechanical
Max Horz
B = 90(load case 4)
Max Uplift
C = - 7(load case 4) B = - 239(load case 3)
D = - 30(load case 3)
Max Gray
C = 67(load case 1) B = 473(load case 1)
D = 61(load case 2)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 59 B -C = -75
BOT CHORD
B -D = 0
CSI
TC 0.52
BC 0.09
WB 0.00
(Matrix)
7) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 7 Ib uplift at joint C, 239 Ib uplift at joint B and 30 Ib uplift at joint D.
8) This truss has been designed with ANSI/TPI 1 -1995 criteria.
Qty
4
DEFL in (loc) I/defl
Vert(LL) 0,01 B -D >999
Vert(TL) 0.20 A -B >160
Horz(TL) -0.00 C n/a
1st LC LL Mini/cleft = 240
Ply
3 -11 -11
3 -11 -11
3 -11 -11
3 -11 -11
SHAW CONST. - TRIPLEX
(optional)
PLATES GRIP
M1120 197/144
Weight: 12 Ib
4.201 SR1 s Nov 16 2000 MiTek Industries, Inc. Tue Oct 15 18:18:13 2002 Page 1
Scale =1:10.:
Job
10021 -02
Truss
J1C
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
LOADING (psf)
TCLL 35.0
TCDL 7.0'
BCLL 0.0
BCDL 7.0
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.8E
BOT CHORD 2 X 4 SPF 1650F 1.6E
A
SPACING 2 -0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code UBC97 /ANSI95
Truss Type
ROOF TRUSS
BRACING
TOP CHORD
Sheathed or 1 -11 -11 oc purlins.
BOT CHORD LOAD CASE(S)
Rigid ceiling directly applied or 10-0 -0 oc bracing. Standard
REACTIONS (Ib /size)
C = -52 /Mechanical B = 427/0 -5 -8
D = 13/Mechanical
Max Horz
B - 68(load case 3)
Max Uplift
C = - 52(load case 1) B = - 236(load case 3)
D = - 16(load case 3)
Max Gray
C = 62(load case 3) B = 427(load case 1)
D = 32(load case 2)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 58 B -C = -67
BOT CHORD
B -D = 0
NOTES
1) This truss has been designed for the wind loads generated by 80 mph winds at
25 ft above ground level, using 7.0 psf top chord dead load and 7.0 psf bottom
chord dead load. 100 mi from hurricane oceanline, on an occupancy category 1,
condition I enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE
7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
2) Design' Toad is based on 35.0 psf specified roof snow bad.
3) Unbalanced snow Toads have been considered for this design.
4) Overhang has been design for 2.00 times live load + dead load.
-2 -4 -0
2 -4 -0 1 -11 -11
CSI
TC 0.45
BC 0.03
WB 0.00
(Matrix)
3.13017
5) This truss has been designed for a 10.0 psf bottom chord live bad
nonconcurrent with any other live loads per Table No. 16-B, UBC -97.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 52 Ib uplift at joint C, 236 Ib uplift at joint 8 and 16 Ib uplift at joint D.
8) This truss has been designed with ANSI/TPI 1 -1995 criteria.
Qty
4
DEFL in (loc) I/defl
Vert(LL) 0.00 B -D >999
Vert(TL) 0.14 A -B >211
Horz(TL) -0.00 C n/a
1st LC LL Min 1/de8 = 240
Ply
3x4 =
SHAW CONST. - TRIPLEX
(optional)
PLATES GRIP
MI120 197/144
Weight: 8 Ib
4.201 SR1 s Nov 16 2000 MiTek Industries, Inc. Tue Oct 15 18:18:13 2002 Page 1
D
Scale = 1:7'
Job
10021 -02
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
Plate Offsets (X Y)J:0 -0- 120 -2 -0]
LOADING (psf)
TCLL 35.0
TCDL 7.0
BCLL 0.0
BCDL 7.0
Truss
K1HJ
LUMBER
TOP CHORD 2 X 4 DF 2400F 2.0E
BOT CHORD 2 X 6 LSL Truss Grade
WEBS 2 X 4 SPF Stud /Std *Except"
W1 2 X 4 SPF 1650F 1.6E
-3 -1 -2
3 -1 -2
SPACING 2 -0 -0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Ina NO
Code UBC97 /ANSI95
BRACING
TOP CHORD
Sheathed or 5 -11 -3 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 9 -2 -7 oc bracing.
REACTIONS (lb /size)
F = 682/Mechanical B = 909/0 -7 -12
Max Horz
B = 144(load case 3)
Max Uplift
F = - 384(load case 3) B = - 471(load case 3)
FORCES (Ib) - First Load Case Only
TOP CHORD
A -B = 63 B -C = -1351 C -H = -78 D -H = 51
D -E = -6 D -F = -302
BOT CHORD
B -I = 1258 G -I = 1258 G -J = 1258 F -J = 1258
WEBS
C -G = 91 C -F = -1293
NOTES
1) This truss has been designed for the wind loads generated by 80 mph winds at
25 ft above ground level, using 7.0 psf top chord dead load and 7.0 psf bottom
chord dead load, 100 mi from hurricane oceanline, on an occupancy category 1,
condition I enclosed building, of dimensions 45 ft by 24 ft with exposure C ASCE
- 7 -93 per UBC97 /ANSI95 If end verticals exist, they are not exposed to wind. If
cantilevers exist, they are exposed to wind. If porches exist, they are exposed to
wind. The lumber DOL increase is 1.33, and the plate grip increase is 1.33
2) Design bad is based on 35.0 psf specified roof snow load.
3) Unbalanced snow loads have been considered for this design.
Truss Type
ROOF TRUSS
5 -10 -0
5 -10 -0
4x5 =
CSI
TC 0.72
BC 0.14
WB 0.78
(Matrix)
Special
Special
5 -10 -0
5 -10 -0
2.69 12
4) Overhang,has been design for 2.00 times live bad + dead load.
5),This truss has been designed for a 10.0 psf bottom chord live Toad
nonconcurrent with any other live bads per Table No. 16-B, UBC -97.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of
withstanding 384 Ib uplift at joint F and 471 Ib uplift at joint B.
8) This truss has been designed with ANSI/TPI 1 -1995 criteria.
9) Special hanger(s) or connection(s) required to support concentrated load(s)
35.0lb up at 5 -8 -3, and 191.91b down and 119.1Ib up at 8 -6-2 on top chord, and
1.71b down and 3.41b up at 2 -10-4, and 54.41b down and 27.11b up at 5 -8-3, and
122.415 down and 80.91b up at 8 -6-2 on bottom chord. Design for unspecified
connection(s) is delegated to the building designer.
LOAD CASE(S)
Standard
1) Snow: Lumber Increase =1.15, Plate Increase =1.15
Uniform Loads (p1f)
Vert:
A -D = -84.0 D -E = -84.0 B -F = -14.0
Concentrated Loads (Ib)
Vert: C =35.0 G = -22.4 H= -191.9 1 =1.4 J= -50.4
Qty
2
DEFL in (roc) I /defl
Vert(LL) 0.07 F -G >999
Vert(TL) 0.49 A -B >84
Horz(TL) 0.01 F n/a
1st LC LL Min I/deft = 240
Ply
Special
Special 304
C
G 3x4 11
Special
Special
SHAW CONST. - TRIPLEX
(optional)
PLATES
M1120
Weight: 58 Ib
4.201 SR1 s Nov 16 2000 MiTek Industries, Inc. Tue Oct 15 18:18:14 2002 Page 1
11 -3 -12
5 -5 -12
Special
Special
H
Special
Special
11 -3 -12
5 -5 -12
GRIP
197/144
Scala =1.18.
1.5x4 11
E
D
4x5 =
LAMi&Pcl, iRAGINU b
TRUt:✓E5 c 24"
0. G. TYP.
102 O 6"
0.G. TV'.
\- ?7P-AGE: WITS . WEB (2xb MAX.
Ion NAILS G 6
0.G. TYP.
HOT*. N G J�(JT (DN
b RAGE MUST 1?2 �0 % THE LENGTH
OP THE WEb. .
THIS t7ETAIL IS TO �E USt7 AS AH
ALT. %OR ONE CONTINUOUS LAT
� RAGE.
AL-T. t_Pc 1917c11,
2�A F,1
- TRU55E5 L� 24" 0.0. TYP.
/
( x4 GRADED LUMBER,OR •
--2X3 OR 2$4 LAT
?'RAGE PER TRUSS
t2EI6.4N WITH 2 -10t7
PER WE, oR CNoRD(TYP
OD
NOTE=
RESTRAINT R0.UIRE2 AT EAG
E HP OP 'RAGE AH2 AT. 20' -0'
INTERNAL 5.
R.,n1 To 1- III, -al SUMMARY
S POR REGOMMENt�ATION�
OP THE 'CROSS PLAT 1NSTUTf
Design Intelligence, LLC
Engineering Calculations Summary
Date: September 12, 2002
Subject: Bowen Student Housing, Rexburg, Idaho
Customer: David Bowen
This analysis uses the Design Criteria required by the local jurisdiction and the 1997 UBC as the basis for the
calculations.
Materials:
Dimensional Lumber - UBC Design Values Used
Concrete: 2500 psi @ 28 days
Reinforcing Steel - #4 and smaller Grade 40, #5 and larger Grade 60
Assumptions:
UBC 1997 — Foundations designed for Max Brg Pressure of 1500 psf
Design Loads:
Snow = 35 psf
Seismic = Seismic Zone 3
Wind = 80 mph, Exposure C
References:
Uniform Building Code, 1997 Edition
Customer Sketches
Summary:
All beam sizes and footing sizes are noted on the drawings.
These calculations and included details are for
this location and customer only and not to be
reused in any manner without the written
consent of Design Intelligence.
Designed B : Scot A Spaulding, P.E.
Date
Checked By:
Date:
Des4gn Intelligence, LLC
135 East Main, Suite A
Rexburg, Idaho 83440
Design Loads
Snow Load:
Wind Load
Seismic
Snow Loads
Roof Pitch
Roof Pitch
Roof Pitch
Roof Pitch
Roof Pitch
Roof Pitch
Wind Loads
Seismic Loads
Run
P= Ce *Cq *qs *Iw
2.5 *Ca *I *W
0.164
BOWEN STUDENT HOUSING
9/12/2002
Reduction
70 mph
12.6
Use
35.0
35.0
32.5
29.9
27.6
25.6
psf
psf
psf
psf
psf
psf
90 mph
20.8
Ca - Zone
2B 3
0.28
0.36
W
Page 1
4
0.44
Design Intelligence, LLC
135 East Main, Suite A
Rexburg, Idaho 83440
BOWEN STUDENT HOUSING 9/12/2002
Type
LVL
GLB
DF
Beam 1 indow Headers
Type Fb psi
Span =
Tributary Area =
Loads
Moment
Live Load Moment =
Dead Load Moment =
Section Modulus Required
Section Width =
Section Depth = in.
Section Modulus Provided =
Moment of Ineritia Provided =
Deflection
Live Load =
Dead Load =
Total =
fv =
FV =
Fb psi
2600
2400
1300
Horizontal Shear
49
109.25
Fv psi E psi
95 1900000
285 1900000
190 1800000
Fv psi
630
270
0.00
0.00
0.01
psi
psi
E psi
lb-ft
lb-ft
in.
42.8
197.9
in.
in.
in.
OK
Allowable
Use
Point Load =
Uniform Load =
8.31
in3
in4
L/360
L/240
3
7560
3240
in3
0.13
0.2
X
0
315
0
135
lb-in
lb-in
in.
in.
Reaction =
9.25
lbs
Ibs /ft
Ibs /ft
Ibs /ft
OK
OK
OK
900
DF
Ibs
Page 1
Design Intelligence, LLC BOWEN STUDENT HOUSING 9/12/2002
135 East Main, Suite A
Rexburg, Idaho 83440
Foundation Design
Allowable Bearing Capacity
Snow Load
Floor Live Load
Wall Dead Load
Roof Dead Load
Brick Dead Load
Floor Dead Load
Exterior Bearing Walls
Roof Loads
Floor Loads
Wall Load
Stem Wall Load
Footing Load
Total
Min Reinforcing Factors
Footing
Stem Wall
Footing
Vertical
Horizontal
Continuous Reinforcing Count
Stem Wall
Continuous Reinforcing Count
Vertical - Reinforcing Spacing
400
0
135
400
133
1068
Reinforcing Requirements
0.002
0.0012
0.002
UBC 1997
Ibs /ft
Ibs /ft
Ibs /ft
Ibs /ft
Ibs /ft
Ibs /ft
1500 psf
3 5 psf
4 0` ; psf
"15 psf
15 psf
z 0 psf
psf
Bearing Pressure =
Page 1
2
3
18
Max Roof Span =
Max Floor Span =
Wall Height =
Stem Wall Height =
Stem Wall Width =
Proposed Footing
bars
bars
in.
801
psf
6- ft
0ft
ft
in.
Width in
Depth in
Reinforcing Bar #4 0 2 in *in
OK
De3ign Intelligence, LLC
135 East Main, Suite A
Rexburg, Idaho 83440
BOWEN STUDENT HOUSING
Shear Wall Analysis - Short Wall
Wind Load
Roof Heigh
Wall Height
Length of L
Area at Mid Height of Wall =
Wind Force =
Seismic Analysis
Roof Dead Load
Shear Wall Length mss ,,; "36 ft
Shear /ft in Wall @ Mid Height
Shear per ft in Wall @ Mid Height
7518
209
Width
Long Wall Length
Short Wall Length
ft
108
psf
ft
296 ft^2
Ibs
Ibs /ft
Provide 1/2" APA rated sheathing with 8d nails at 6" o.c. at
panel edges and 12" o.c. in the field. Blocking is required.
Length
Seismic Multiplier =
Load
(includes snow)
Wall Dead Load
Height Length Load
106 G.
Weight
17280
Ibs
Ibs
Weight
6360
Shear Wall Length
Seismic Force @ Mid Height of Wall
Ibs /ft
OK
Provide 1/2" APA rated sheathing with 8d nails at 6" o c. at
panel edges and 12" o.c. in the field. Blocking is required.
3877
Ibs
Page 1
9/12/2002