HomeMy WebLinkAboutCO & DOCS - 03-00063 - Woodshed Properties - Three 4-Plexes Bldgs #2,3,4Building Permit No: R- o3 -o9 -17
Applicable edition of code: ❑ International Building Code 2000
❑ International Residential Code 2000
❑ Uniform Building Code 1 997
Site address: 355 West 2nd South
Use and occupancy: Residential (three four plexes — 12 units)
Type of construction: Wood Frame
Design occupant load: Family Units
Sprinkler System required: ❑ Yes ❑ No
Name and address of owner: KDS Developing (Kevin Snell)
P.O. Box 463
Rigby, Idaho 83442
Contractor: KDS Developing (Kevin Snell)
Special conditions:
Occupancy:] Full 0 Partial ❑ Temporary
CERTIFICATE OF OCCUPANCY
City of Rexburg
Department of Building Inspection
This Certificate, issued pursuant to the requirements of Section 109 of the International
Building Code, certifies that, at the time of issuance, this building or that portion of tbe
building that was inspected on the date listed was f ouno to be in compliance with the
requirements of tbe code for the group and division of occupancg an the use for which the
proposed occupancN was classif ieo.
Date: March 8, 2004 (1o:
C.O. Issued by:
:
Building Offi a
There shall be no future change in the existing occupancy classification of the building nor shall
any structural changes, modifications or additions be made to the building or any portion thereof
until the Building Official has reviewed and approved said future changes.
Water Departmen
State of Idaho Electrical Depart m e
Fire Department
t - (208 -366 -4830) ❑ Merlin Webster
BUILDING PERMIT APPLICAT ON REXBURG, ID DATE NO
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED
OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS.
OWNER
BUILDING
INSPECTOR
BUILDER
STRUCTURE:
0 RESIDENCE OMM.
FOOTINGS
CONCRETE
❑ MASONRY
❑ OTHER
EW O Ft « EMODEL
JOB ADDRESS
AF(CHITECT
O ADDITION
CI REPAIR
DESIGNER f
FOUNDATION
BASEMENT
IOCONCRETE 0 PARTIAL
'O MASONRY 0 FULL
0 OTHER QNO
0 EDUCATIONAL 0 GOVT O RELIGIOUS O FENCE p PATIO O CARPORT p GARAGE
FLOORS
'U.W000
0 CONCRETE
0 OTHER
EXT. WALLS
WOOD
,U MASONRY
O CONCRETE
0 VENEER
O METAL
O STUCCO
INT. WALLS
WOOD
0 MASONRY
O CONCRETE
ta DRYWALL
p PLASTER
❑ TILE
CEILING
O WOOD
)DRYWALL
❑ PLASTER
O TILE
O ACOUSTIC
O OPEN
ROOF
c BUILT UR
O WOOD SH.
0 COMP. SH.
O TILE
0 ROLL ROOF
O METAL
HEAT
p GAS
0 0IL
❑ COAL
O FIREPLACE
sp ELECTRIC
O RENEWAL
WHITE-Owner's Copy CANARY - Building Department's Copy PINK - Assessor's Copy GOLDENROD - Inspector
O FIRE DAMAGE
p AWNING
INSULATED
3 WALLS
a CEILING
Q FLOORS
❑ PERIMETER
This permit is issued subject to the regulations contained in the Uniform Building Code and Zoning Regulations of Rexburg, and it is hereby agreed
that the work to be done as shown in the plans and specifications will be completed in accordance with the regulations
pertaining and applicable thereto: The issuance of the permit does not waive restrictive co'enants.
REMARKS:
CITY (IF REXBURG
SEP3 0ZOO
APPLICATION FOR BUILDING PERMIT
CITY OF REXBURG, IDAHO
1
Date of Application 9`' ( V° 3 Permit No. • 0 3- V n
OWNER
Name 600 MS 7 ) P P 77 cy4�,
Site Address /V 0 S ✓ t t/6 2 3 T '
Mailing Address P U d'-44 476 3
City/State /Zip g 4B / ! � 3 VV 2
Telephone/Fax/Mobile 1 - 62 7 0? C8 3 ( cd(-
CONTRACTOR
Name
Mailing Address P 2 -z' 3
City/State /Zip 1 (6 5 c l 3
Telephone/Fax/Mobile 1 4`S ' 6 2 5 - F 707 -- o& 3 (
PROJECT INFORMATION
Property Zone: ?"'� -1J Is existing use compatible with zoning, (screening parking, etc)
When was this building last occupied /V6C) £Y k'
Architect/ Engineer Firm 60 CE ( J / 1 6 a'n Name
Subdivision
Will there be an apartment?
Signature of Applicant
New House
Building Type
DEPARTMENT APPROVAL
Circle One Residential (Commercial
Circle One
Circle One Basemen Finished / Unfmished
Lot Square Footage Lot Width
S uare Feet / 7510 Gara S uare Feet /VA Number of Stories
2 5 ;1 6ru t used for: 5 Home Home Business
C 5
Educational Government
Addition/Remodel to House
Lot
Total Estimated Cost Are you in a flood plain
oD Sile6
Block
Remodel Other
New Commercial Commercial Remodel
Other: None/ Patio/ Carport/ Awning N/A
z Height of Building
Commercial Other
If so, how many units ! 2_- 3 ` T' fZe
********************************************************************* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **
Code Building Permit Fees 3 5
Zone Plan Check Fees 3s-i.
Plumbing Permit Fees 9 q 9 oD
Digging Permit Fees
Water & Sewer Fees 0 Si.
Front Footage Fee
TOTAL $ 1 3 9 G.
Signature of Inspector
Issued by
Rough Plumbing
°-
Septic Tank
Fixtures /
I
t�
Neter Piping
Complete
Sewer
CITY OF REXBURG
APPLICATION FOR PLUMBING PERMIT
OWNER FEES
Name " : ,a Plumbing Permit
Address Tel. Sewer Inspection $
Lot BIk. Add. $
Name
PLUMBER
Address Tel.
Bath Tubs
Showers
Laundry Trays
Wash Basin
Toilet
Slop Sinks
Kitchen Sinks
NATURE OF INSTALLATION
Use
DESCRIPTION OF WORK
Urinal
Sink Trap
Water Heater
Other
Lawn Sprinklers
Floor Drain
Drinking Fountains
Water Softeners
Dish washing Mach.
Clothes Washer
Inspection of Pipe
CITY OF REXBURGY
SEP 3 0 2003
PAID CASH $ ___. - - --
ECK$
Rough Plumbing
Sewer
Other
Finish Plumbing'
Inspection of Fixtures ...... • • • • • • • • $
$
S
$
INSPECTOR'S RECORD
N
FO3Vc°(
TOTAL $
Received: Date
By
INSP.. NAME
Excavation &
Earthwork: D/2 T �
Concrete: % 1
Masonry: - y / I
Roofing: (1 ( /J c t_
Insulation: ,
Drywall:
Painting:
Floor Coverings: (" y e, g ,
Plumbing:
o e40 AVc:17 tit -11
Heating: L:-'. �' (r ZC:
Electrical: rei2 f7 9 ?C .
Roof Trusses:
Floor / Ceiling Joists:
Cabinets:
Siding /Exterior Trim:
Other:
SUBCONTRACTOR LIST
SPECIAL CONSTRUCTION
(Manufacturer or Supplier)
Td Wd80:ET 200E 6Z 'daS
1
ee;t 4 ksi,&-uA
4Tr 16A- /30112-C
m 3 55e- 3c> 2Z
e ;(43-2",-
- z9 -
6TTP6ZS80z : '0N Xdd
lEdeJUO 8.4 : W0�! li
t5c /LO(AfQr / Apr Z
eu/Lpmk. Pr 4 ,
13u a. o . -w 3 Ar- / z, 3 4
gut LO /A( l'r # /
75 u/ L /.I 5 m' A 1, z / //
�d
iv62
( ?L' 1
- 761- oR3 C L`
?C/5--- 67_51? 06"
/„
W cb
4A) ?- .
gex ecrszg f &39 D
Ed Wd60:ET 200E 6E 'da5
6TTb6ES80E : '0N Xdd
IDN
b<)0 -0056( e'D Paaerer 5 14 ,
18dNUD NW : Wald
•
•
•
•
•
•
•
•
MI
facsimile transmittal
To: Mark Evans
Fax: 661- 947 -3050
From: Val Christensen Date: 5/19/2006
Re: Woodshed Apts. Pages: 2 with cover
❑ Urgent x For Review ❑ Please Comment ❑ Please Reply ❑ Please Recycle
Notes: Let me know if there is anything else I can help you with. Val
City of
Rexburg
a
5/18/2006
Mark Evans
Woodshed Apartments
Dear Mark,
Val Christensen
Building Official
I am responding to a request from Jon Berry concerning the crawl space ventilation of
the Woodshed Apartments. The International Building Code requires crawl spaces to be
vented to the outdoors or be conditioned space that is heated and vented. As per Jon Berry
the crawl spaces in the Woodshed buildings meets neither of these requirements. The plans
for the apartments identify that the lower floor was to be insulated. This configuration
would require the crawlspace to be vented to the outside.
When the apartments were constructed, the Subcontractor who built the foundation
was instructed to install vents in the foundations. The Contractor obviously decided to
disregard the plans and the direction from the Building Inspector and made unauthorized
changes by insulating the stem walls and not providing adequate ventilation.
I apologize that we did not catch the mistake before the Certificate of Occupancy was
issued. We simply don't catch everything. The problem must be fixed as soon as possible.
Damage to the structure can occur if the crawlspace holds too much moisture. If you have
any questions, I can be reached at (208)359 -3020 ext. 324.
Yours truly,
Cc: Stephen Zollinger
Jon Berry
Val Christensen Building Official 19 E. Main Rexburg, ID 83440 P. 0. Box 280 valcgrexburg.org wiww.rexbur'.ojg
Phone (208) 3593020 ext.324 Fax (208) 359.3022
9/18/2003
Scott Spaulding
Design Intelligence
3685 HHwy. 33
Rexburg, Idaho 83440
Dear Scott,
STATE OF IDAHO
www.ci.rexburg.id.us
P.O. Box 280
12 North Center Street
Rexburg, ldaho 83440
Phone (208) 359 -3020
Fax (208) 359 -3022
e -mail rexburg @ci.rexburg.id.us
I have finished the review of the Kevin Snell — Woodshed Apartment drawings
that you have provided for me and have identified the following discrepancies:
1. Please provide 2 handicapped parking spaces complete with access aisles.
2. A handicapped route must be provided from the entrance of each building. It
must connect all buildings, parking, accessible spaces (patio, mail boxes etc.)
and the public way. The route must be built at a 5% (1/20) slope or less,
unless handrails are provided, then it is considered a ramp and must not
exceed 8.33% (1/12) slope. Please identify elevations of the required access
routes on site plan so that handicap access can be reviewed.
3. Change drainage so it does not take place on adjacent properties. Include
elevations for parking, access aisles and easement areas.
4. Asphalt or concrete is required at all vehicle parking and access. This will
include the access easement areas.
5. Compact parking spaces must be in their own row and identified with signs.
6. The 2000 International Building Code (IBC) requires that buildings of this
occupancy and type be of one hour construction if closer than 10' from a
property line. Please either change the building location or provide details of
one hour construction.
7. A fence or a buffer strip is required around the parking area where it is
adjacent to other residential property. Please identify on plans.
8. Call out door sizes on plans. All lower units must be built as "Type B" units
as per the IBC. Type B units are required to have an accessible path
throughout. The entry doors of the lower units must have levered handles.
9. Please provide stair details. Include rise, run, handrail heights, guardrail
heights, headroom and all dimensions.
10. How are the units heated? If a furnace is to be provided, please identify its
location.
11. Page S2 identifies a "F3" footing on the foundation plan. The F3 description
on the same page has been crossed out. Please make the necessary changes.
12. Please identify special thickened washers for the anchor bolts as per the IBC.
13. Page A.5 (cross section details) has not been stamped.
14. The foundation on page A.5 is identified as both a concrete and a block type.
Please make the necessary changes.
15 Simpson hangers are identified on page A.S. The "Main Floor Framing Plan"
on page S2 does not identify these hangers and does not show the rim joists
constructed with a brick ledge as per page A.S. Please make the necessary
changes.
16. Page A.5 identifies 5/8" drywall at the one hour ceilings. Please change to
match the one hour ceiling detail on page S4.
17. Please provide truss details prior to framing inspection.
18. Provide energy calculations as per the 2000 International Energy
Conservation Code (IECC).
19. The Fire Department has reviewed the plans. I have attached a copy of their
report. Please provide the necessary information they have requested.
Please return two sets of revised plans. Let me know if I can be of any further
assistance. If you have any questions, please give me a call at 359 -3020 ext. 324.
Sincerely,
Val Christensen
Building Official
cc John Millar
Chris Huskinson
n o
(G t 2extur
STATE OF IDAHO
REXBURG- MADISON COUNTY
EMERGENCY SERVICES
26 NORTH CENTER STREET
REXBURG, IDAHO 83440
208 -359 -3010
208 -359 -3006 FAX
2000 International Fire Code Plan Date: 9 -11 -03
Plan Review Review Date: 9 -19 -03
Building Name: SNELL APARTMENTS
Building Address: 4 WEST AND SECOND SOUTH
Stories: 2 Type of Construction: V -B
Occupancy Classification: R -2 Existing Floor Area: N/A
New Construction Floor Area: APPROXIMATELY 3,332 SQUARE FEET
1. Required Fire Flow (Appendix B): 1,500 GPM/TWO HOURS
Comments:
2. Water Supply (Section 508, Appendix C) Required: YES
Fire Hydrant Location: 2 SOUTH AND 4 WEST, ONE NEW PROPOSED
Fire Hydrant Flows: EXISTING OK
Fire Flow Test Location: 2 SOUTH AND 4 WEST
Fire Flow Supplied By: RMCES
P.O. Box 280
12 North Center Street
Rexburg, Idaho 83440
Phone (208) 359 -3020
Fax (208) 359 -3022
e -mail rexburg @srv.net
Other Approved Water Source: NONE
Water Supply Acceptable: YES, WITH NEW HYDRANT INSTALLED
Fire Hydrant Location Acceptable: NO
Water Supply Comments: PLANS SHOW ONE NEW HYDRANT ON 2 SOUTH,
PLEASE LOCATE WITHIN COMPLEX
3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES
Acceptable Width: YES
Complete Road Acceptable: YES
Length: YES Surface: YES
Comments: FIRE LANES TO BE MARKED WITH SIGNS AND RED PAINTED
CURBS AS NOTED. SOUTH EGRESS INTO EAST HOUSE SHOWS TOO
SHARP OF A CORNER. IT WOULD BE BETTER TO MOVE PARKING
SPACES TO THE EAST TO WIDEN ACCESS AND IMPROVE THE CORNER.
4. Access Roads and Water Supply, including fire hydrants are required to be installed
and made serviceable prior to and during time of construction (Section 501):
Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE
OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED.
5. Installation of portable fire extinguishers (Section 906) Required: YES
Location shown: NOT ACCE.PTABI E T provided acceptable: YES
Comments: PLANS SHOW FIRE EXTINGUISHER MOUNTED ABOVE
KITCHEN CABINETS. EXTINGUISHERS MUST BE MOUNTED IN THE
KITCHEN AREA IN AN UNOBSTRUCTED AND ACCESSIBLE LOCATION IN
EACH UNIT.
6. Automatic fire extinguishing systems (Section 903) Required: NO
Type of system being installed:
Sprinkler system monitoring (Section 907) required:
Comments:
7. Standpipes (Section 905) required: NO
Type required: Comments:
8. Ventilating hood and duct fire extinguisher system (Section 609) required: NO
Type being provided:
Automatic fuel shut -off required:
Portable fire extinguisher shown:
Comments:
9. Fire alarm systems (Section 907) required: YES
Type of system required: Manual: Automatic: X Both:
Type of system being provided: Manual: Automatic: Both:
Components of system shown: Smoke Detectors: X Heat Detectors:
Manual Pull Station: Sounding Devices: Visual Devices:
Door Holders: Duct Detectors: Flow Alarm:
Sprinkler Valve Monitoring:
Fire Alarm System Acceptable: YES
10. Other corrections that are required by special occupancy or conditions:
Plans as submitted are acceptable: YES, WITH ABOVE ITEMS ADDRESSED
PRIOR TO BUILDING PERMIT BEING ISSUED.
Plans checked by: CHRIS HUSKINSON Date: 9 -19 -03
Please furnish comments back to the plan reviewer in the following manner:
Written Comments: X New Plans: X
Designed B • Scott A Spauldin
P.E.
Checked By:
Date: ��
Date:
Date: September 11 2003
Subject.
Customer: Kevin Snell
Design Intelligence, LLC
Engineering Calculations Summary
Snell Apartments, Rexburg, Idaho G- o ®S C- b
This analysis uses the Design Criteria required by the local jurisdiction and the IBC 2000 as the basis for the
calculations.
Materials:
Dimensional Lumber — NDS 1997 design values
Concrete: 2500 psi @ 28 days
Reinforcing Steel - #4 and smaller Grade 40, #5 and larger Grade 60
Assumptions:
IBC 2000 — Foundations designed for Max Brg Pressure of 1500 psf increased for depth
Design Loads:
Roof Live Load (min) — 20 psf during construction
Ground Snow load = 50 psf,
Roof Snow load= 35 psf
Snow Load Importance Factor — 1.0
Snow Exposure Factor — 0.9
Wind = 90 mph, Exposure B
Wind Importance Factor -- 1.0
Wind Exposure = B
Seismic Design Category — D1
Seismic Use Group - 1
References:
IBC 2000
TrusJoist MacMillian Design Guides
Summary:
All beam sizes and footing sizes are noted on the drawings.
These calculations and included details are for
this location and customer only and not to be
reused in any manner without the written
consent of Design Intelligence.
Design Parameters
35
Snow Load:
psf
Snow Loads
Rise
3
4
6
7
8
10
12
Run
12
12
12
12
12
12
12
Reduction
Use
Roof Pitch
0.0
psf
35.0
psf
Roof Pitch
0.0
psf
35.0
psf
Roof Pitch
2.5
psf
32.5
psf
Roof Pitch
3.8
psf
31.2
psf
Roof Pitch
5.1
psf
29.9
psf
Roof Pitch
7.4
psf
27.6
psf
Roof Pitch
9.4
psf
25.6
psf
Wind
90 mph
1
B
Design Wind Speed
Importance Factor
Exposure
Simplified Method
Section 1609.6
Applicable loads are shown in bold letters.
Horizontal Loads
End Zone
Interior Zone
Transverse
Wall
Roof
Wall
Roof
< 5:12
12.8
-6.7
8.5
-4
5:12
17.8
-4.7
11.9
-2.6
> 5:12
14.4
9.9
11.5
7.9
Longitudinal
12.8
-6.7
8.5
-4
Vertical Loads
End Zone
Interior Zone
Winward Overhang
Transverse
Windward
Leeward
Windward
Leeward
End Zone
Interior Zone
Roof
Roof
Roof
Roof
< 5:12
-15.4
-8.8
-10.7
-6.8
-21.6
-16.9
5:12
-15.4
-10.7
-10.7
-8.1
-21.6
-16.9
> 5:12
5.6
-8.8
4.8
-7.5
-5.1
-5.8
Longitudinal
-15.4
-8.8
-10.7
-6.8
-21.6
-16.9
Maximum Horizontal Wall Loads
Transverse
Zone
1E
4E
1
4
< 5:12
9.8
-7.5
7.2
-5.8
5:12
12.1
-10.1
8.8
-7.5
> 5:12
10.7
-8.1
9.1
-6.8
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 1
Longitudinal
9.8
-7.5
7.2
-5.8
Component and Cladding
Design Wind Pressures - Table
1609.6.2.1(2
Roof
Zone
Area
< 5:12
5:12
> 5:12
1
10
10
-14.6
10
-13.3
13.3
-14.6
1
20
10
-14.2
10
-13
13
-13.8
1
50
10
-13.7
10
-12.5
12.5
-12.8
1
100
10
-13.3
10
-12.1
12.1
-12.1
2
10
10
-24.4
10
-28.2
13.3
-17
2
20
10
-21.8
10
-25.6
13
-16.3
2
50
10
-18.4
10
-22.1
12.5
-15.3
2
100
10
-15.8
10
-19.5
12.1
-14.6
3
10
10
-36.8
10
-28.2
13.3
-17
3
20
10
-30.5
10
-25.6
13
-16.3
3
50
10
-22.1
10
-22.1
12.5
-15.3
3
100
10
-15.8
10
-19.5
12.1
-14.6
Wall
4
10
14.6
-15.8
4
20
13.9
-15.1
4
50
13
-14.3
4
100
12.4
-13.6
5
10
14.6
-19.5
5
20
13.9
-18.2
5
50
13
-16.5
5
100
12.4
-15.1
Roof Overhang Component and Cladding Design Wind Pressures - Table 1609.6.2.1(3)
Zone
Area
< 5:12
5:12
> 5:12
2
10
-21
-27.2
-24.7
2
20
-20.6
-27.2
-24
2
50
-20.1
-27.2
-23
2
100
-19.8
-27.2
-22.2
3
10
-34.6
-45.7
-24.7
3
20
-27.1
-40.5
-24
3
50
-17.3
-33.6
-23
3
100
-10
-28.4
-22.2
1609.6.2.1(4) Height and Exposure Adjustment Coefficient =
1
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 2
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 3
Seismic
Reference Code - IBC 2000
Values for Ss, S1, Fa and Fv are taken
from Code Control CD using Zip Code
1615.1.2.(1)
Fa
1615.1.2(2)
Fv
0.606
0.193
1615.1
Ss
g
1615.1
SI
g
Fa
Fv
Site Class A - Hard Rock
0.8
0.8
Site Class B - Dense Soil or Soft Rock
1
1
Site Class C - Stiff
Site Class D - Soft
Soil
Soil
1.2
1.32
D
1.7
2.03
0.79992
0.39179
Site Class
A
B
C
1615.1.2
SMS = FaSs
0.4848
0.606
0.7272
1615.1.2
SM1 = FvS1
0.1544
0.193
0.3281
Design Spectral Resp Accel
0.535946
0.262499
1615.1.3
SDS = 2 /3 *SMS
0.324816
0.40602
0.487224
SDI = 2 /3 *SMI
0.103448
0.12931
0.219827
1616.2 Seismic Use Group
1616.3 Seismic Design Category
Group I - Non - Essential
D
D
Table 1616.3(1)
Table 1616.3(2)
Seismic Response Coefficient
1
6
1
1617.6 (Table 1617.6) Response Modification Factor R =
1616.2 (Table 1604.5) Occupancy Importance Factor I =
Basic Fundamental Period
Ct
Steel Moment Resisting Frame
0.035
Reinforced Concrete Moment Resisting Frame
0.03
All Other Building Systems
0.02
37
1.31
Building Height
ft
Table 1617.4.2 Cu =
Approximate Fundamental
Period
0.39
Ta = Ct *hn ^3/4 =
sec
Rigid Bldg
D
0.0893
0.0172
0.0236
Site Class
A
B
C
Cs = SDS /(R/I) =
0.0541
0.0677
0.0812
Max Cs = SDI /(R/OT =
0.0068
0.0085
0.0144
Min Cs = 0.044SDS *I =
0.0143
0.0179
0.0214
Design Seismic Response Coefficient
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 3
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 4
D
0.0236
Site Class
A
B
C
Cs =
0.0143
0.0179
0.0214
0.0236
0.10719
1617.4.1 Equiv Lateral Force Method
V = CsW =
W
1617.5.1 Simplified Approach
V = 1.2 *(SDS /R) *W =
W
Determine Method of Seismic Analysis
Light Framing Construction Criteria
3
9
15
40
50
90
40
2308.2.1 Building stories
stories
YES
2308.2.2 Bearing wall floor to floor height
ft
YES
2308.2.3.1 Average DL
psf
YES
2308.2.3.2 Floor Live Loads
psf
YES
2308.2.3.3 Ground Snow Load
psf
YES
2308.2.4 Wind speed
mph
YES
2308.2.5 Truss Span
ft
YES
1616.6.1 Simplified Analysis Requirements
YES
YES
1. Does Building meet light frame construction criteria ?
2. Is building of any other construction with flexible diaphragms at
every level as defined in section 1602 ?
Building may use Simplified Analysis Method
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 4
Type
Fb psi
Fv psi
E psi
LVL
2600
285
1900000
GLB
2400
190
1800000
DF
1300
95
1900000
Beam 1
Overbuild
Ridge
Type
LVL
Fb psi
2600
Fv psi
285
E psi
1900000
Span =
11
12
ft
Tributary Area =
ft
0
Loads
Point Load =
Ibs
Snow
35
0
15
psf
Uniform Load =
420
Ibs /ft
Live Load
psf
0
Ibs /ft
Dead Load
psf
180
Ibs /ft
Moment
Live Load Moment =
6353
lb-ft
=
76230
lb-in
Dead Load Moment =
2723
lb-ft
=
32670
lb-in
Section Modulus Required
=
41.88
in3
Section Width = 3.5 in.
Section Depth = 9.5 in.
Section Modulus Provided =
52.6
in3
OK
Moment of Ineritia Provided =
250.1
in4
1
Deflection
Live Load =
0.29
in.
L/360
0.37
in.
OK
Dead Load =
0.12
in.
Total =
0.42
in.
L/240
0.55
in.
OK
Horizontal Shear
fv =
149
psi
OK
FV =
327.75
psi
Allowable
Reaction =
3300
Ibs
Use
3.5
X
9.5
LVL
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 1
Type
Fb psi
Fv psi
E psi
LVL
2600
285
1900000
GLB
2400
190
1800000
DF
1300
95
1900000
Beam 2
Overbuild Rafters
Type
DF
Fb psi
1300
Fv psi
95
12
2
E psi
1900000
1
Span =
ft
Tributary Area =
ft
0
Loads
Point Load =
lbs
35
0
15
Snow
psf
Uniform Load =
70
Ibs /ft
Live Load
psf
0
Ibs /ft
Dead Load
psf
30
Ibs /ft
Moment
Live Load Moment =
1260
lb-ft
=
15120
lb-in
Dead Load Moment =
540
lb-ft
=
6480
lb-in
Section Modulus Required
=
16.62
in3
1.5
9.25
Section Width =
in.
Section Depth =
in.
Section Modulus Provided =
21.4
in3
OK
Moment of Ineritia Provided =
98.9
in4
Deflection
Live Load =
0.17
in.
L/360
0.40
in.
OK
Dead Load =
0.07
in.
Total =
0
in .
L/240
0.6
in.
OK
Horizontal
Shear
fv =
65
psi
OK
FV =
109.25
psi
Allowable
Reaction =
600
Ibs
Use
1.5
X
9.25
DF
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 2
Type
Fb psi
Fv psi
E psi
LVL
2600
285
1900000
GLB
2400
190
1800000
DF
1300
95
1900000
Beam 3
Bearing Wall Window Headers
Type
DF
Fb psi
1300
Fv psi
95
4
18
E psi
1900000
Span =
ft
Tributary Area =
ft
0
Loads
Point Load =
Ibs
35
0
15
Snow
psf
Uniform Load =
630
Ibs /ft
Live Load
psf
0
Ibs /ft
Dead Load
psf
270
Ibs /ft
Moment
Live Load Moment =
1260
lb-ft
=
15120
lb-in
Dead Load Moment =
540
lb-ft
=
6480
lb-in
Section Modulus Required
=
16.62
in3
3
9.25
Section Width =
in.
Section Depth =
in.
Section Modulus Provided =
42.8
in3
OK
Moment of Ineritia Provided =
197.9
in4
Deflection
Live Load =
0.01
in.
L/360
0.13
in.
OK
Dead Load =
0.00
in.
Total =
0.01
in.
L/240
0.2
in.
OK
Horizontal
Shear
fv =
97
psi
OK
FV =
109.25
psi
Allowable
Reaction =
1800
Ibs
Use
3
X
9.25
DF
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 3
Type
Fb psi
Fv psi
E psi
LVL
2600
285
1900000
GLB
2400
190
1800000
DF
1300
95
1900000
Beam 4
Elevated Walkway Beam
Type
STEEL
Fb psi
26800
Fv psi
14400
29
1.5
E psi
29000000
Span =
ft
Tributary Area =
ft
0
Loads
Point Load =
Ibs
0
60
15
Snow
psf
Uniform Load =
0
Ibs /ft
Live Load
psf
90
Ibs /ft
Dead Load
psf
22.5
Ibs /ft
Moment
Live Load Moment =
9461
lb-ft
=
113535
lb-in
Dead Load Moment =
2365
lb-ft
=
28384
lb-in
Section Modulus Required
=
5.30
in3
1
15
Section Width =
in.
Section Depth =
in.
Section Modulus Provided =
11.3
in3
OK
Moment of Ineritia Provided =
45.1
in4
1
Deflection
Live Load =
0.73
in.
L/360
0.97
in.
OK
Dead Load =
0.27
in.
Total =
1.00
in.
L/240
1.45
in.
OK
Horizontal
Shear
fv =
163
psi
OK
FV =
14400
psi
Allowable
Reaction =
1631.25
Ibs
Use
TS8x4x1 /4
STEEL
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 4
Type
Fb psi
Fv psi
E psi
LVL
2600
285
1900000
GLB
2400
190
1800000
DF
1300
95
1900000
Beam 5
Door Header Below Elevated Walkway Beam
Type
DF
Fb psi
1300
Fv psi
95
3
5
E psi
1900000
Span =
ft
Tributary Area =
ft
1650
Loads
Point Load =
Ibs
35
0
15
Snow
psf
Uniform Load =
175
Ibs /ft
Live Load
psf
0
Ibs /ft
Dead Load
psf
75
Ibs /ft
Moment
Live Load Moment =
1434
lb-ft
=
17212.5
lb-in
Dead Load Moment =
84
lb-ft
=
1013
lb-in
Section Modulus Required
=
14.02
in3
3
9.25
Section Width =
in.
Section Depth =
in.
Section Modulus Provided =
42.8
in3
OK
Moment of Ineritia Provided =
197.9
in4
Deflection
Live Load =
0.01
in.
L/360
0.10
in.
OK
Dead Load =
0.00
in.
Total =
0.01
in.
L/240
0.15
in.
OK
Horizontal
Shear
fv =
109
psi
OK
FV =
109.25
psi
Allowable
Reaction =
1200
Ibs
Use
3
X
9.25
DF
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS 9/11/2003
REXBURG, IDAHO
Page 5
Foundation Design
Allowable Bearing Capacity
2000
psf
Max Roof Span = 38 ft
Max Floor Span = 36 ft
Snow Load
35 psf
Wall Height = 18 ft
Floor Live Load
40 psf
Stem Wall Height = 4 ft
Wall Dead Load
15 psf
Stem Wall Width = 8 in.
Roof Dead Load
15 psf
Brick Dead Load
0 psf
Floor Dead Load
15 psf
Exterior Bearing Walls - F1
Proposed
Footing
Roof Loads
950
Ibs /ft
Width 20 in
Floor Loads
990
Ibs /ft
Depth 10 in
Wall Load
270
Ibs /ft
Stem Wall Load
400
Ibs /ft
Footing Load
208
Ibs /ft
Total
2818
Ibs /ft
Bearing Pressure =
1691
psf
OK
Reinforcing Requirements
Min Reinforcing Factors
Footing
0.002
Stem Wall
Vertical
0.0012
Horizontal
0.002
Reinforcing Bar
#4 0.2
in*in
Footing
Continuous Reinforcing Count
2
bars
Stem Wall
Continuous Reinforcing Count
4
bars
Vertical - Reinforcing Spacing
18
in.
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS
REXBURG, IDAHO
Page 1
9/11/2003
Foundation Design
0
36
18
4
8
Allowable Bearing Capacity
2000
psf
Max Roof Span =
ft
35
80
15
15
0
30
Max Floor Span =
ft
Snow Load
psf
Wall Height =
ft
Floor Live Load
psf
Stem Wall Height =
ft
Wall Dead Load
psf
Stem Wall Width =
in.
Roof Dead Load
psf
Brick Dead Load
psf
Floor Dead Load
psf
Interior Bearing Walls - F2
Proposed Footing
20
10
Roof Loads
0
Ibs /ft
Width
in
Floor Loads
1980
Ibs /ft
Depth
in
Wall Load
270
Ibs /ft
Stem Wall Load
400
Ibs /ft
Footing Load
208
Ibs /ft
Total
2858
Ibs /ft
Bearing Pressure =
1715
psf
OK
Reinforcing Requirements
1
Min Reinforcing Factors
Footing
0.002
Stem Wall
Vertical
0.0012
#4
0.2
Horizontal
0.002
Reinforcing Bar
in *in
Footing
Continuous Reinforcing Count
2
bars
Stem Wall
Continuous Reinforcing Count
4
bars
Vertical - Reinforcing Spacing
18
in.
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS
REXBURG, IDAHO
Page 2
9/11/2003
Shear Wall Analysis - Upper Floor
Wind Load =
22
psf
Roof Height =
8
9
ft
Wall Height =
ft
Length of Long Wall =
54
ft
Area at Mid Height of Wall =
675
ft ^2
1
Wind Force =
14850
Ibs
Shear Wall Length
72
ft
Shear /ft in Wall @ Mid Height
206
Ibs /ft
Provide 1/2" APA rated sheathing with 8d nails at 6" o c. at panel edges
and 12" o.c. in the field. Blocking is Required.
Seismic Analysis
Seismic Multiplier =
0.107
Width
Length
Load
Weight
Roof Dead Load
40 58
24
(includes snow)
55680
Ibs
Long Wall Length
54
30
ft
Short Wall Length
ft
Height
Length
Load
Weight
Wall Dead Load
9
168
15
11340
Ibs
Seismic Force @ Mid Height of Wall
7171
Ibs
Shear Wall Length
72
ft
Shear per ft in Wall @ Mid Height
100
Ibs /ft
OK
Provide 1/2" APA rated sheathing with 8d nails at 6" o c. at panel
edges
and 12" o.c. in the field. Blocking is Required.
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS
REXBURG, IDAHO
Page 1
9/11/2003
Shear Wall Analysis - Main Floor
22
8
28
54
1188
Wind Load =
psf
Roof Height =
ft
Wall Height =
ft
(applies Toad at mid wall)
Length of Long Wall =
ft
Area at Mid Height of Wall =
ft ^2
Wind Force =
26136
Ibs
108
Shear Wall Length
ft
(shear party wall)
Shear /ft in Wall @ Mid Height
242
Ibs /ft
Provide 1/2" APA rated sheathing with 8d nails at 6" o.c. at panel edges
and 12" o.c. in the field. Blocking is Required.
. •
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
SNELL APARTMENTS
REXBURG, IDAHO
Page 2
9/11/2003