Loading...
HomeMy WebLinkAboutCO, APP & DOCS - 03-00021 - American Manor Apartments - RemodelBuilding Permit No: CITY OF REXBURG AMERICA'S FAMILY COMMUNITY R- o3 -o5 -o7 Applicable edition of code: ❑ International Building Code 2000 ❑ International Residential Code 2000 ❑ Uniform Building Code 1 997 Site address: American Manor -151 South 1st East Use and occupancy: Apartments Type of construction: Wood Frame Design occupant load: Residential Units Sprinkler System required: ❑ Yes ❑ No Name and address of owner: Tamala Rencher 1748 Jeppson Ave Idaho Falls, ID 83404 Contractor: Jim Mortensen Special conditions: Occupancy: ❑ Full This Certificate, issued pursuant to the requirements of Section 109 of the International Building Code, certifies that, at the time of issuance, this building or that portion of the building that was inspected on the date listed was found to be in compliance with the requirements of the code for the group and division of occupancy and the use for which the proposed occupancy was classified. Date: August 17, 2005 C.O. Issued by: Y Building Official 'UNITY DEVELOPMENT DEPARTMENT 19 E. Main (PO Box 280) Rexburg, Idaho 83440 www. rexbu ro. oro ❑ Partial ❑ Temporary Phone: 208- 359 -3020 x326 Fax: 208 - 359 -3024 cathyw@ci.rexburg.id.us There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and approved said future changes. i Plumbing Departure s _ Fire Department •� State of Idaho Electrical Department - ( 08- 356 -483o) ❑ Merlin Webster 'd The City of Rexburg certifies that this unit is approved for occupancy until the date listed on this document. Apartment Address Unit 1 Y Numrbef of occupants 74 Date of inspection / 1) for 9 /1 Certificate of Occupancy m a 3 1,5 1 . . -. S131 9NIN80IJ p(W fl' - aun t•-ni wa..c► 90: t . 300 -0'_ -.111.1 VALUE FEE PAID BUILDING INSPECTOR DEPARTMENT OF BUILDING & ZONING PAID CASH$ DATE ADDRESS a . BUIL PERMIT APPLICA REXBURG, ID DATE A THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNER BUILDER STRUCTURE: *RESIDENCE FOOTINGS *CONCRETE MASONRY MASONRY Y O OTHER REMARKS: " i i . /1 ' !'. JOB ADDRESS / " 1 j # n r re. Kt ARCHITECT 0 NEW 0 REMODEL 0 ADDITION *REPAIR 0 COMM. 0 EDUCATIONAL 0 GOVT 0 RELIGIOUS 0 FENCE 0 PATIO BASEMENT r PHONE DESIGNER 0 RENEWAL U FIRE 0 CARPORT 0 GARAGE O AWNING INSULATED FOUNDATION CRETE MASONRY 0 OTHER 0 PARTIAL la FULL O FLOORS O WOOD aaCONCRETE 0 OTHER EXT. WALLS WOOD 0 MASONRY ' O CONCRETE 0 VENEER 0 METAL O STUCCO INT. WALLS 0 WOOD 0 MASONRY 0 CONCRETE a DRYWALL 0 PLASTER O TILE CEILING ❑ woo() DRYWALL PLASTER 0 TILE 0 ACOUSTIC 0 OPEN ROOF HEAT MOIL OIL 0 COAL 0 FIREPLACE ❑ ELECTRIC 0 BUILT UP. O WOOD SH. COMP. SH. 0 TILE 0 ROLL ROOF. This 0 METAL permit is issued subject to the regulations contained in the Uniform Building Code and Zoning Regulations of Rexburg, and it is hereby agreed that the work to be done as shown in the plans and specifications will be completed in accordance with the regulations pertaining and applicable thereto: The issuance of the permit does not waive restrictive covenants. I CEI WALLS 0 FLOORS 0 PERIMETER Date of Application OWNER Name Site Address Mailing Address City /State /Zip Telephone/Fax/Mobile ,(Q g CONTRACTOR Name 47/'rrl /4"-10 r i xt' I,t. Mailing Address r 'Ty �,� City /State /Zip /q F 4k , Telephone/Fax/M elephone/Fax/Mobile a Qg " 3 S °t e' e ° 7 PROJECT INFORMATION Property Zone: ' .3 Circle One Circle One Circle One '1 a /sc. 1s/ Commercial Edu New House Basement: None/ Will there be apartment? )4J Total Estimated Cost Si Code Zone Building T APPLICATION FOR BUILDING PERMIT CITY OF REXBURG, IDAHO 2 9 -- 63 IA. Svµ /k / st ,E.gs f' 1C vE: 3(2 /5 Cfvty r ture or Appl PAID CASH $ CHECK$ MAY 8 2003 Is existing use compatible with zoning, (screening parking, etc) When was this building last occupied I Amp- Architect/ Engineer Firm i/', �� ifftvif,4 Plan Name Subdivision DRPARTMENT APPROVAL Lot Width CITY OF REXBURG 6y9V Permit No. K 3 " _ 07 .7 ' 4 Lot ,`q 3 Block . S0 Government Remodel Other P*5' New Commercial Commercial Other If so, - how many units /S Are you in a flood plain - l 0 Commercial Remodel Other: None/ Patio/ Carport/ Awning N/A Lot Square Footage Square Feet /9 4V SO Garage Square Feet Number of Stories $ Height ..Building What will structure be used for: Home Home Business Building Permit Fees / Plan Check Fees / 7 2 Plumbing Permit Fees Digging Permit Fees Water & Sewer Fees Front Footage Fee TOTAL S !i s SiDlature of Tnspector Issued by Excavation & Earthwork: Concrete: / Y , 4 Masonry: 4 , Roofing: N , A, Insulation: e r ! ►� °+ a k- Drywall: rY1 /Yip f J t k Sr b -� Painting: V r` r r 1 ► Floor Coverings: ,rr, wt Plumbing: Heating: s A Electrical: ‘At of Roof Trusses: /V 4 Floor / Ceiling Joists: 6, 44 Cabinets: .4 Siding /Exterior Trim: .. Other: , SUBCONTRACTOR LIST SPECIAL CONSTRUCTION (Manufacturer or Supplier) TO: DATE: I hereby request, pursuant to Idaho Code Section 9 -338, to examine and/or copy the following public records: Nor ? Z Te %e ipt v ❑ These records specifically pertain to myself. ❑ I wish to merely examine these records. I wish copies of these records. Printed Name: Mailing Address: Telephone Number: Signature: REQUEST TO EXAMINE /COPY PUBLIC RECORDS ki( �L C ,1412.1Avi Iu I) CD 5o J 2_2_ 1 acknowledge my signatur- that e records sortght by this request will not be used for a mailing list or teleph . e list 's set forth in Idaho Code Section 9 -348. Please allow us ten working days to complete your request. This request has been reviewed by city attorney on the day of . 200_. Said request is hereby: ❑ Approved ❑ Denied City Attorney Date: t — ^L(,,, _ c i To: Planning Department From: - N i KtA hI 0 5 (\ m Property: i t ,t A OP\ aJul ) ( ( 5, (5r ; +St t _6 E Zed 5o. Kaxblf Tel. No.: Project No. V7 07— (1 2t Fax No.: Please respond by Fax to Nova Consulting Group, Inc. 3979 East Arapahoe Road, Suite 100 Centennial, Colorado 80122 Phone: (303) 734 -0270 Fax: (303) 734 -0425 I. What is the date of construction? Name & Signature of Building Official/ Inspector Title: Request for Information BUILDING/PLANNING DEPARTMENT N � Consulting Group, Inc. Nova Consulting Group, Inc. has been commissioned to conduct an environmental assessment on the above referenced property. As part of our research and report compilation we seek public information from municipal agencies regarding compliance with state and local codes. We would appreciate your response to the following documentation/information requests: I et /5 — 247o ( 2. What is the historical use of the property (prior to development)? ES 1 PE17Adt. 3. What is the current zoning? Mak .. tl. 1 s1c1el'i11I \ (AAv �� 4. Have there been any documented spills or releases associated with the property 1 &K 5. Are there any registered underground or aboveground tanks listed for the property? (4 N / 6. Have there been any solid or hazardous waste disposal facilities at the Site? uN /4 7. Are there any violations associated with the environmental integrity of the property? ti N K p i Thank you for your assistance. Should you have any questions associated with providing the requested information, please call me at the above number. Note: Please contact us at the above numbers if you require any additional information or require a fee to complete this inquiry. Date: ' t 3 1 loci) To: Inspections and Code Enforcement Department From: PIA `lL J 4 0 , et.") Property: H L .- - A. 1iw.cif p � V1 5 t 'c :r 1 Of + d- ) 2-5 E 2rA , R &xh■;. Tel. No.: Project No. 6 07 - 0 2 if Fax No.: Please respond by Fax to Nova Consulting Group, Inc. 3979 East Arapahoe Road, Suite 100, Centennial, CO 80122 Phone: (303) 734 -0270 Fax: (303) 734 -0425 REQUEST FOR INFORMATION BUILDING DEPARTMENT Nova Consulting Group, Inc. has been commissioned to conduct a condition assessment survey on the above referenced property. As part of our research and report compilation, we seek public information from municipal agencies regarding compliance with state and local building codes. We would appreciate your response to the following documentation/information requests: .7)o#4 hlfelf 5.7 rs/N 1. What is the current use group? 2. What is the current construction classification? V 9 3. What is the seismic zone? U A C - 3 7 G 7) 4. What is the current applicable building code and date including amendments? 2003 ZB C 5. Does the Property have any material outstanding building code violations or notice of deficiencies? Yes ❑ No 4 If "Yes ", please fax copies. 6. Please fax a copy of the current certificate of occupancy. i CO` )% \ iS Qn 'lair?! Di 7. What is the flood zone? No7 /w 114,00 �olll� Thank you for your assistance. Should you have any questions associated with providing the requested information, please call me at the above number. Name & Signature of Building Official/ Inspector Title: Note: Please contact us at the above numbers if you require any additional information or require a fee to complete this inquiry. Det er i- ( - fl'j To: Planning Department From: . 44 Min 5 Property: p � rntr:r 6n 8ant i+f�r5 1 (5. 15r Edit 4. IrE 2.4 SO. a) C b'r9 J Tel. No.: Project No. 5 07- (12. Fai No.: Date /Time: Feb. 5. 2007 1:05PM File No. Mode * Memory TX Result Report ( Feb. 5. 2007 1:06PM ) * * * Destination 3630 Memory TX 13037340425 P. 2 OK Reason for error E. 1) Hang up or 1 i ne fail E. 3) No answer E . 5 ) E x c e e d e d max. E - m a i l s i z e Name & Signature of Building O9lolall Inspector Tide: Request for Information BUILDING/PLANNING DEPARTMENT Page Pg (s) Result Not Sent E. 2) Busy E. 4) No facs imi 1 e connect ion Nova` comwa glleimO. Please respond by Fax to Nova Consulting Group, Inc. 3979 East Arapahoe Road, Suite 100 Centennial, Colorado 80122 Phone: (303) 734 -0270 Fax: (303) 734 -0425 Nov Conaalliog Group, Inc. has been commissioned to conduct on em rmmental amasmeot on the above rdereeced properly. As port of oar research and report compilation we seek public fnformadan from musicipel agencies regarding oomphanoe with state and local codes. We would appreciate yourrvspome to the following ddoeamentaUOnlloformoYm requests: 1. What is the date ofeonsbwctioa4 ............... 1 l � rP Zoo . . . . . . . . . . . . . . . . . . . . . . . — . 2. What is the historical use of the property (prior to development)?....... ���,t f` ttof "� ,,,,,1,, t11 3. What Is the earrentmaing4...........» ...... ..........».... ......... ......_..._.IYN.GltItt f...DZY L' .•' A 1A �re&1 there 4. Haw ere ban any documented spills or releases assodated with theproperq T......M.csp!1M4 `M C) 5. Are there any registered underground or aboveg000d tanks listed for the p, operty?_cle 6. Have there been any mad or huardous waste disposal facilities at the Sim ? ................ ` Nom) 7. Are mere any violations associated with the environmental Integrity of the property........ u t5 tif**1 Thank you for your sadstauoe. Should you have any questions unseated with providing the requested information, plasm call me at the above number. Nolo Phase contact us at the above numbers if you require any additional information or regaire a forte complete this iagniry. 1) 2) P 1 Ms. Tamla Rencher 836 N Skyline Dr Idaho Falls, Idaho 83402 Reference: Structural Deficiencies Ms. Rencher Pat Bragassa, P.E. 167 N 4800 E Rigby, Id 83442 Per your request, I have inspected your apartment building located at 139 S 1 East in Rexburg, Idaho, and have the following report. The apartment complex is made up of several apartment buildings under the name "American Manor Apartments ". The building subject of this report is the northwest most building of this group. This building is currently under renovation. During this renovation, the city building inspector has placed a stop work order or "red tag" on the work to address structural concerns brought to his attention. The intent of this report is to address these concerns and provide a structural evaluation of the facility for the building owner. I inspected the building on 4/18 with the owner and contractor present and again by myself on 4/21. The procedure and method used for this evaluation is based on inspection and detailed calculations as needed. Building performance and response over its lifetime is given due consideration. Material testing and Non - destructive Examination were not performed and the condition assessment was based on visual inspection of the building components and its response to the loads sustained over the years. The building is a wood framed, three story structure with engineered trusses for the roof framing, 2x6 stud exterior walls, 2x12 floor joists and 8 "' thick reinforced concrete foundation. The exterior stairs and walkways are constructed of 4 "thick corrugated decking and steel tube framing. The renovation work previously performed has exposed many areas within the building which allows sufficient inspection to determine the general construction features of the building. Inspection and Evaluation Summary: The building was constructed in the late 1980's and shows the expected amount of usage and wear for a college area apartment building. The overall construction quality of this building was fairly poor. 1. Building Exterior: The tube steel framed columns supporting the stairs and walkways are rusting and require maintenance. I recommend removing the rust and repainting to prevent further deterioration. Several of these columns have been deformed due to water being trapped inside and freezing. All columns that have been deformed in this manner should be replaced. The tops of the columns should be capped and a means for the water to drain out should be added. Many of the base plates anchoring the columns to the foundation are missing nuts, are loose, or are missing bolts completely. The base plates without bolts should be modified by drilling through the plates and into the concrete and installing W' diameter Hilti Kwik Bolt II (or Equal) with a minimum embedment of 2 -1/2 ". Nuts should be added to all bolts currently without them. This walkway and stair system is the means of egress from this building in the event of an emergency, and it is therefore critical that a structural sound support system be provided. The building owner discussed the possibility of expanding the ground floor apartments out to the existing concrete wall approximately 4 -ft from the currently wall. This existing concrete wall is approximately 4 ft tall (varies), bears on a footing on rock and supports the front bearing wall of the apartments above by beams and columns By expanding the ground floor out to this wall and building a framed bearing wall, the structural integrity of the building would be much stronger, by providing a better method of shear transfer and bearing. The columns currently supporting the second floor wall provides questionable shear transfer to the foundation. The 8" thick foundation wall is adequate for supporting this new bearing wall. 2. Roof Overhang at south east comer. It was noted by the owner of a potential problem with the roof overhang at the south east comer of the building. The roof extend approximately 4 -ft past the bearing wall in this location. An analysis determined that this indeed does overstress the 2x6 truss tails that support this portion of the roof. A design of a type of support bracket to correct this condition has been included with this report. 3. Exposed Foundation at southwest corner. A question was raised concerning the exposed footing at this location causing frost heaving. Due to the elevation of bedrock in this area, it is unlikely that heaving is possible, but cannot be ruled out. The expansion of the ground floor bearing wall will correct this potential by enclosing and covering this portion of the foundation. 4. Building Interior. There are many areas of shoddy construction within the building, many of which the owner is already in the process of upgrading and correcting. Calculations were performed to check the sizing of the major structural components such as joists, studs, floor beams and trusses. 5. Roof Trusses. The roof trusses on the east side of the building appear to be of a unique design and construction. Although questionable in appearance they were found to be adequate for the loads and span. 6. Floor Joists: The living room portion of each of the second and third story apartments are supported by 2x12 floor joists at 16 " on center spanning 19'2 ". Calculations show that for this span these joist are overstressed for the design live load value of 40 psf. The 1.5 -inch thick gypsum concrete floor deck adds greatly to the dead load contribution on these joists , but also help distribute loads and limits deflection, which is probably why the floor loading has not shown up in a visible means such as ceiling cracks, or excessive deflections in the floor. To correct this, a new 2x12 joist (No.2 or better) shall be added between every other joist within the 19' span areas of the building (living rooms only). This will add 5 joists to each room. The sheet rock should be removed and the joist jacked or otherwise fitted into position to guarantee they will support the floor. This work may only need to be perfounied on the third floor framing, as it appears the second floor framing is approximately 4 -ft shorter due to the inset of the ground floor bearing wall. This was not visible during the inspection and should be verified in the field. 7. Door Headers. The door framing is being modified to provide a break between the new windows being installed and the door frame. This will also provide a better transfer of shear forces in these walls. It is recommended that the header bear on a minimum of 1 -1/2" (1 stud) and be tied to the adjacent headers or built up columns with Simpson tie plates. Although not specifically required by code, this does help provide a continuous tie across these walls weakened by the large openings. Overall the building has many areas of poor quality construction and is need of substantial renovation, but structurally has shown no significant indications of distress, or failure. The building main structural components appear to have supported the imposed loads fairly well over the years despite the construction appearance and I can see no reason for continued usage with the specified modifications. If there are any questions concerning this evaluation, or if at any time during the renovation please contact me at 538 -7845. Pat Bragass , P.E. 1\ (z t 31(0 A / - - balk f , I N A 6 7 yt 1...-4..6 co, 4.1 r , ) N • - \,7"(-1/ 4 ` eir k. 'CAP evAs G4 3U pLf4. L(A SLO N54) - sXi sT RazESti- Pfrer gs--4