HomeMy WebLinkAboutBP, CO & DOCS - 03-00059 - Leonard's Insurance - New BuildingBIJ11.[)11\IG PE
Date Approved
9- /t- 03
CITY OF REXBURG
ISSUED TO:
NAME: t ii a LeotniLe'dsow.. - PERMIT# —O 3 —09 — 'I
FOR THE CONSTRUCTION OF: CO ,.n vh e rc t< l JOB ADDRESS: Ifi41/e cu ide Sr t L !S
GENERAL CONTRACTOR: n t`q a, tti, a e� �'�.J
This permit is issued, subject to the regulations contained in Building Code and Zoning Regulations of the
City of Rexburg. It is specifically understood that this Permit does not allow any Variance to the regulations
of the City of Rexburg Building or Zoning Codes unless specifically approved by the City Council and
explained on the Building Permit Application as approved by the Building Inspector.
Issue ���
Building Inspector
THIS PERMIT MUST BE PROMINENTLY DISPLAYED AT THE BUILDING SITE
THE BUILDING MAY NOT BE OCCUPIED OR USEDWITHOUT FIRST OBTAINING A CERTIFICATE OF OCCUPANCY .
NOTICE
1) A complete set of approved drawings along with permit must be kept on the
premises during construction.
2) The permit will become null and void in the event of any deviation from the
accepted drawings.
3) No foundation, structural, electrical, nor plumbing work shall be concealed
without approval.
No work shall be done on any part of
the building beyond the point
indicated In each successive
inspection without approval.. No
structural framework of any part of the
building or any underground work
shall be covered or concealed without
approval.
INSPECTION RECORD
BUILDING
1st Layout
2nd Footing
3rd Foundation
4th Truss
5th Framing
6th Drywall
7th Sidewalk
8th Final
9th Occupancy
ELECTRICAL
1st Groundwork
2nd Rough -in
3rd Final
PLUMBING
1st Trench
2nd Service Connection
3rd Rough -in
4th Heat Cable
5th Final
For Inspections Cali 359 -3020
24 Hour Notice
A CERTIFICATE OF OCCUPANCY CAN NOT BE ISSUED PRIOR
TO FINAL ELECTRICAL & PLUMBING INSPECTIONS.
CERTIFICATE OF OCCUPANCY
City of Rexburg
Department of Building Inspection
Building Permit No: R- 03 -09 -11
Applicable edition of code: ❑ International Building Code 2000
❑ International Residential Code 2000
❑ Uniform Building Code 1 997
Site address: 1109 Summers Drive
Use and occupancy: Commercial
Type of construction: Wood Frame
Design occupant load:
Sprinkler System required: ❑ Yes ❑ No
Name and address of owner: David Leonardson
P.O. Box 267
Dubois, Idaho 8 34 2 3
Contractor: Morgan Beattie Construction
Special conditions:
Occupancy: ❑ Full
This Certificate issued pursuant to tie requirements of Section 109 of tbe International
Bui((ing Odle, certifies tbat at the time of issuance this building or tbat portion of tbe
bui(bing tbat was / inspected on tbe bate listed was f oune to be in compliance with the
requirements of the code for the group and biUision of occupancj and the use for which the
propose occupancy was c(assi f ieb.
Date: February 24, 2004
C.O. Issued by:
❑ Partial ❑ Temporary
Building Official
There shall be no future change in the existing occupancy classification of the building nor shall
any structural changes, modifications or additions be made to the building or any portion thereof
until the Burl ' g Ofcial has revi wed and approved said future cyan: - es. /
Water Department 1 z e 7 Cc , ...: ��re Department
C 7"
State of Idaho Electrical Department - (208 - 356-4830) ❑ Merlin Webster
CHECK $
DEPARTMENT OF BUILDING & ZONING
❑ CASH
CHECK
FCIC
APPLICANT
BUIL G PERMIT APPLICA } REXBURG, ID DATE
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED
OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS.
OWNER
BUILDER 4
STRUCTURE:
0 RESIDENCE
FOOTINGS
'a:CONCRETE
U MASONRY
U OTHER
REMARKS:
VALUE
FEE PAID
BUILDING
INSPECTOR
0 NEW
comm.
0 REMODEL
O EDUCATIONAL
JOB ADDRESS
ARCHITECT
0 ADDITION
0 GOVT 0 RELIGIOUS 0 FENCE 0 PATIO
DATE
❑ REPAIR
PHONE
DESIGNER
0 RENEWAL
0 CARPORT
0 GARAGE
0 FIRE DAMAGE
O AWNING
INSULATED
FOUNDATION BASEMENT
FLOORS EXT. WALLS
0 CONCRETE
0 MASONRY
0 OTHER
0 PARTIAL
0 FULL
O NO
WOOD WOOD
0 CONCRETE RY
0 OTHER Lt CONCRETE
0 VENEER
O METAL
0 STUCCO
INT. WALLS
O WOOD
0 MASONRY
0 CONCRETE
DRYWALL
PLASTER
O TILE
CEILING
ROOF
0 WOOD
G} DRYWALL
O PLASTER
O TILE
O ACOUSTIC
0 OPEN
0 BUILT UP.
0 WOOD SH.
WCOMP. SH.
0 TILE
0 ROLL ROOF
0 METAL
HEAT
I5tGAS
0 COAL
O FIREPLACE
O ELECTRIC
This permit is issued subject to the regulations captained in the Uniform Building Code and Zoning Regulations of Rexburg, and it is hereby agreed
that the work to be done as shown in the plans and specifications will be completed in accordance with the regulations
pertaining and applicable thereto: The issuanceeof the permit does not waive restrictive covenants.
ADDRESS
WHITE - Owner's Copy CANARY- Buedng Department's Copy PINK - Assessors Copy GOLDENROD-Inspector
3 WALLS
Cir CEILING
O FLOORS
coPPERIMETER
1,
Date of Application
OGST.NER
Mailing Address
_ City /State /Zip
Telephone/Fax/Mobile
CONTRACTOR
Name
City /State /Zip (p
TeIephone/Fax/Mobile
PROJECT LNFORMAy[ON
Property Zone:
Total Estimated Cost
, P-g 1,7 7 3
Signature of Applicant
Code
Zone
Building Type
Signature of Tnspect
Issued by
APPLICATION FOR BL 11, DEG PERMIT
CM OF RErOURG, IDAHO
-7 -O3
0
l:Iail irg Address " c9 9 5 � . �t \IJ
Is existing use compatible with zoning, (screening parking etc)
When was this building lash occupied NM
Architect/ Engineer Firm Da il h 1 44--el �,,,,n / „ j sG
1 , ' J ��Q Plan ?dame L�'�'�l/?as C�- � 5 1/1 S U 6'7 YI«
Subdivision \ICAA.l e,L1 (A) b CC-0-'0p / Lot / 5 Block
Circle One Resident' Commer ' } Educational Government Remodel Other
Circle One New House Addinon/R. model to House Cew Commerci Commercial Remodel
Circle One Basement: None/ Finished / nfinis Other. None/ Patio/ Carport/ Awnin N/A
Lot Square Footage cQg i 010 Lot Width / 50 '
Square Feet 1-1 Li Garage Square Feet AA Number of Stories
What will structure be used for: Home Home Business Apartment
Will there be an apartment? NO
* * * * * * * * * * * * * * **
CITY, OF REXBURG
SEP 1 6 2003
PAID CASH $
;;HECK $
DEPART1VMNT APPROVAL
Permit No.
T -hPigo- l- nf cji
(Commercial) Other
If so, many units
Are you in a flood plain go
Building Permit Fees
Plan Check Fees
TOTAL S
rasa
Plumbing - Permit Fees
Digging Permit Fees
Water & Sewer Fees / 9 RA, Q°
Front Footage Fee
a"
. 1 e ) , '
V..7,
Rough Plumbing
{.-Septic Tank
Fixtures
Water Piping
Complete
#7
Sewer
PLUMBER
Name t . ` cf a (� � 1 1 4 t V
Address
Bath Tubs
Showers
Laundry Trays
Wash Basin
Toilet
Slop Sinks
Kitchen Sinks
Floor Drain
Drinking Fountains
Water Softeners
Dish Washing Mach.
Clothes Washer
D ESC
CITY OF REXBURG
APPLICATION FOR PLUMBING PERMIT
OWNER FEES
Plumbing Permit $ I
Sewer Inspection $
Inspection of Pipe $
Inspection of Fixtures $
Name
Address €. f 'v, 1 t ?✓"t Tel
Lot Bik. Add.
Tel.
NATURE OF INSTALLATION
Use
Received: Date
By
TOTAL $
INSPECTOR'S RECORD
N
1= u I4°
RIPTION OF WORK
Urinal
Sink Trap
Water Heater
Other
Lawn Sprinklers
CITY OF REXBUR
w
SEP 1 6 2003
PAID CASH $
CHECK$
Rough Plumbing
Sewer
Other
Finish Plumbing
S
INSP.. NAME
E
Excavation &
Earthwork:
Insulation:
Drywall:
Cabinets:
SUBCONTRACTOR LIST
Concrete: CtaO$ + w 1ioo
Masonry: BrA/r4" hc(,t)i Plat4e,r;rby,
Roofing: Beerttl f- Cc I/ 5 .4C4-co
Wal
Painting: St-to. a vte t e , r5o YL
Floor Coverings: 3hOpp Y"\C a I DU hct
Plumbing: lijay&d �L �jI
Heating: 12et,40 R€Cei V14_
c
Electrical UJ & &, E( -j C
SPECIAL CONSTRUCTION
(Manufacturer or Supplier)
Roof Trusses: Sin c . CO VV, \O d IAMI s
Floor / Ceiling Joists: TA I ( 5
Siding /Exterior Trim: GUY* t S
(aS4,r'I
Other:
9/10/2003
Scott Spaulding
Design Intelligence
3685E Hwy. 33
Rexburg, Idaho 83440
Dear Scott,
STATE OF IDAHO
www.ci.rexburg.id.us
I have reviewed the Leonardson's Insurance Building drawings that you have
provided me and have identified the following discrepancies:
1. The site plan's scale is not 1/4" = 1' as identified on the drawing. Please
rescale the drawing to a common scale.
2. Provide spaces at the ends of the parking lot aisles so vehicles have an area to
back out.
3. Parallel parking spaces are not long enough. A minimum of 23' is required.
4. Provide plans for storm drainage.
5. Provide sidewalk with landscape strip at front of property.
6. The handicap ramp has a greater than 6" rise. Provide handrails as per the
I Building. Code (IBC) Section 1003.3.4.7. Also please provide an
accessible route to the public way as per IBC Section 1104.3.
7. Provide parking lot access approach details that identify 6" thick concrete
with #4 rebar at 18" o.c. in both directions.
8. Provide truss details prior to frame inspection.
9. Please provide structural calculations and the necessary energy calculations.
10. The Fire Department has reviewed the plans. I have attached a copy of there
report to the back of this document. Please provide the necessary information
they have requested.
Please return two sets of revised plans. Let me know if I can be of any further
assistance. If you have any questions, please give me a call at 359 -3020 ext. 324.
Val Christensen
Building Official
cc John Millar
Chris Huskinson
P.O. Box 280
12 North Center Street
Rexburg, Idaho 83440
Phone (208) 359 -3020
Fax (208) 359 -3022
e -mail rexburg@ci.rexburg.id.us
C ijOly m 2exhiry
STATE OF IDAHO
REXBURG- MADISON COUNTY
EMERGENCY SERVICES
26 NORTH CENTER STREET
REXBURG, IDAHO 83440
208 -359 -3010
208 -359 -3006 FAX
2000 International Fire Code Plan Date: 8 -5 -03
Plan Review Review Date: 9 -5-03
Building Name: LEONARDSON'S INSURANCE
Building Address: WEST MAIN STREET, NEXT TO VALLEY WIDE COOP
Stories: ONE Type of Construction: V -B
Occupancy Classification: B Existing Floor Area: N/A
New Construction Floor Area: APPROXIMATELY ^1 SQ AA E I EEi T
�/Q.. 4
A V SQUARE FEET
1. Required Fire Flow (Appendix B): 1750 GPM/TWO HOURS
Comments: FIRE FLOW REQUIREMENTS MAY BE REDUCED IF
AUTOMATIC FIRE SPRINKLER SYSTEM INSTALLED.
2. Water Supply (Section 508, Appendix C) Required: YES
Fire Hydrant Location: MAIN AND 14 WEST
Fire Hydrant Flows: OK
Fire Flow Test Location: SAME
Fire Flow Supplied By: FD
P.O. Sox 280
12 North Center Street
Rexburg, Idaho 83440
Phone (208) 359 -3020
Fax (208) 359 -3022
e -mail rexburg @srv.net
Other Approved Water Source: NONE
Water Supply Acceptable: YES
Fire Hydrant Location Acceptable: YES
Water Supply Comments: NONE
3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES
Acceptable Width: OK
Complete Road Acceptable: YES
Comments: NONE
Length: OK Surface: OK
4. Access Roads and Water Supply, including fire hydrants are required to be installed
and made serviceable prior to and during time of construction (Section 501):
Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE
OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED.
5. Installation of portable fire extinguishers (Section 906) Required: YES
Location shown: NO Type provided acceptable: NOT SHOWN
Comments: PROVIDE MINIMUM 2A1OBC FIRE EXTINGUISHER WITHIN
TRAVEL DISTANCE ON EACH LEVEL
6. Automatic fire extinguishing systems (Section 903) Required: NO
Type of system being installed:
Sprinkler system monitoring (Section 907) required:
Comments:
7. Standpipes (Section 905) required: NO
Type required: Comments:
8. Ventilating hood and duct fire extinguisher system (Section 609) required: NO
Type being provided:
Automatic fuel shut -off required:
Portable fire extinguisher shown:
Comments:
9. Fire alarm systems (Section 907) required: NO
Type of system required: Manual: Automatic: Both:
Type of system being provided: Manual: Automatic: Both:
Components of system shown: Smoke Detectors: Heat Detectors:
Manual Pull Station: Sounding Devices: Visual Devices:
Door Holders: Duct Detectors: Flow Alarm:
Sprinkler Valve Monitoring:
Fire Alarm System Acceptable:
10. Other corrections that are required by special occupancy or conditions: NO
Plans as submitted are acceptable: YES
Plans checked by: CHRIS HUSKINSON Date: 9 -5 -03
Please furnish comments back to the plan reviewer in the following manner:
Written Comments: New Plans:
1 \ew 1 1a13s,
Designed y Scot A Spau +din , P.E.
Checked By:
Dat
Date:
.
Date: September 15, 2003
Subject:
Customer: Leonardson's Insureance
Design Intelligence, LLC
Engineering Calculations Summary
exburg, Idaho
This analysis uses the Design Criteria required by the local jurisdiction and the IBC 2000 as the basis for the
calculations.
Materials:
Dimensional Lumber — NDS 1997 design values
Concrete: 2500 psi @ 28 days
Reinforcing Steel - #4 and smaller Grade 40, #5 and larger Grade 60
Assumptions:
IBC 2000 — Foundations designed for Max Brg Pressure of 1500 psf increased for depth
Design Loads:
Roof Live Load (min) — 20 psf during construction
Ground Snow load = 50 psf,
Roof Snow load= 35 psf
Snow Load Importance Factor — 1.0
Snow Exposure Factor — 0.9
Wind = 90 mph, Exposure B
Wind Importance Factor — 1.0
Wind Exposure = B
Seismic Design Category — D1
Seismic Use Group - 1
References:
IBC 2000
Customer Drawings
TrusJoist MacMillian Design Guides
Summary:
All beam sizes and footing sizes are noted on the drawings.
These calculations and included details are for
this location and customer only and not to be
reused in any manner without the written
consent of Design Intelligence.
Design Parameters
35
Snow Load:
psf
Snow Loads
Rise
3
4
6
7
8
10
12
Run
12
12
12
12
12
12
12
Reduction
Use
Roof Pitch
0.0
psf
35.0
psf
Roof Pitch
0.0
psf
35.0
psf
Roof Pitch
2.5
psf
32.5
psf
Roof Pitch
3.8
psf
31.2
psf
Roof Pitch
5.1
psf
29.9
psf
Roof Pitch
7.4
psf
27.6
psf
Roof Pitch
9.4
psf
25.6
psf
Wind
90 mph
1
B
Design Wind Speed
Importance Factor
Exposure
Simplified Method
Section 1609.6
Applicable loads are shown
in bold letters.
Horizontal Loads
End Zone
Interior Zone
Transverse
Wall
Roof
Wall
Roof
< 5:12
12.8
-6.7
8.5
-4
5:12
17.8
-4.7
11.9
-2.6
> 5:12
14.4
9.9
11.5
7.9
Longitudinal
12.8
-6.7
8.5
-4
Vertical Loads
End Zone
Interior Zone
Winward Overhang
Transverse
Windward
Leeward
Windward
Leeward
End Zone
Interior Zone
Roof
Roof
Roof
Roof
< 5:12
-15.4
-8.8
-10.7
-6.8
-21.6
-16.9
5:12
-15.4
-10.7
-10.7
-8.1
-21.6
-16.9
> 5:12
5.6
-8.8
4.8
-7.5
-5.1
-5.8
Longitudinal
-15.4
-8.8
-10.7
-6.8
-21.6
-16.9
Maximum Horizontal Wall
Loads
Transverse
Zone
1E
4E
1
4
< 5:12
9.8
-7.5
7.2
-5.8
5:12
12.1
-10.1
8.8
-7.5
> 5:12
10.7
-8.1
9.1
-6.8
Deign Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE 9/15/2003
REXBURG, IDAHO
Page 1
Longitudinal
9.8
-7.5
7.2
-5.8
Component and Cladding
Design Wind Pressures - Table 1609.6.2.1(2)
Roof
Zone
Area
< 5:12
5:12
> 5:12
1
10
10
-14.6
10
-13.3
13.3
-14.6
1
20
10
-14.2
10
-13
13
-13.8
1
50
10
-13.7
10
-12.5
12.5
-12.8
1
100
10
-13.3
10
-12.1
12.1
-12.1
2
10
10
-24.4
10
-28.2
13.3
-17
2
20
10
-21.8
10
-25.6
13
-16.3
2
50
10
-18.4
10
-22.1
12.5
-15.3
2
100
10
-15.8
10
-19.5
12.1
-14.6
3
10
10
-36.8
10
-28.2
13.3
-17
3
20
10
-30.5
10
-25.6
13
-16.3
3
50
10
-22.1
10
-22.1
12.5
-15.3
3
100
10
-15.8
10
-19.5
12.1
-14.6
Wall
4
10
14.6
-15.8
4
20
13.9
-15.1
4
50
13
-14.3
4
100
12.4
-13.6
5
10
14.6
-19.5
5
20
13.9
-18.2
5
50
13
-16.5
5
100
12.4
-15.1
Roof Overhang Component and Cladding Design Wind Pressures - Table 1609.6 2.1(3)
Zone
Area
< 5:12
5:12
> 5:12
2
10
-21
-27.2
-24.7
2
20
-20.6
-27.2
-24
2
50
-20.1
-27.2
-23
2
100
-19.8
-27.2
-22.2
3
10
-34.6
-45.7
-24.7
3
20
-27.1
-40.5
-24
3
50
-17.3
-33.6
-23
3
100
-10
-28.4
-22.2
1
1609.6.2.1(4) Height and Exposure Adjustment Coefficient =
Deign Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE
REXBURG, IDAHO
Page 2
9/15/2003
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE 9/15/2003
REXBURG, IDAHO
Page 3
Seismic
Reference Code - IBC 2000
Values for Ss, S1, Fa and Fv are taken
from Code Control CD using Zip Code
1615.1.2.(1)
Fa
1615.1.2(2)
Fv
0.511
0.164
1615.1
Ss
g
1615.1
SI
g
Fa
Fv
Site Class A - Hard Rock
0.8
0.8
Site Class B - Dense Soil or Soft Rock
1
1
Site Class C - Stiff
Site Class D - Soft
Soil
Soil
1.2
1.32 `
1.7
2.03
D
0.674256
0.333732
Site Class
A
B
C
1615.1.2
SMS = FaSs
0.40864
0.5108
0.61296
1615.1.2
SM1 = FvS1
0.13152
0.1644
0.27948
Design Spectra Resp Accel
0.451752
0.2236
1615.1.3
SDS = 2/3 *SMS
0.273789
0.342236
0.4106832
SDI = 2 /3 *SMI
0.088118
0.110148
0.1872516
1616.2 Seismic Use Group
1616.3 Seismic Design Category
Group I - Non - Essential
1
D
D
Table 1616.3(1)
Table 1616.3(2)
Seismic Response Coefficient
1
6
1
1617.6 (Table 1617.6) Response Modification Factor R =
1616.2 (Table 1604.5) Occupancy Importance Factor I =
Basic Fundamental Period
Ct
Steel Moment Resisting Frame
0.035
Reinforced Concrete Moment Resisting Frame
0.03
All Other Building Systems
0.02
20
1.49
Building Height
ft
Table 1617.4.2 Cu =
Approximate Fundamental
Period
0.28
Ta = Ct *hn ^3/4 =
sec
Rigid Bldg
D
0.0753
0.0105
0.0199
Site Class
A
B
C
Cs = SDS /(R/I) =
0.0456
0.0570
0.0684
Max Cs = SDI /(R/I)T =
0.0041
0.0052
0.0088
Min Cs = 0.044SDS *I =
0.0120
0.0151
0.0181
Design Seismic Response Coefficient
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE 9/15/2003
REXBURG, IDAHO
Page 3
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE 9/15/2003
REXBURG, IDAHO
Page 4
D
0.0199
Site Class
A
B
C
Cs =
0.0120
0.0151
0.0181
0.0241
0.09035
1617.4.1 Equiv Lateral Force Method
V = CsW =
W
1617.5.1 Simplified Approach
V = 1.2 *(SDS /R) *W =
W
Determine Method of Seismic Analysis
Light Framing Construction Criteria
1
8
15
50
35
90
0
2308.2.1 Building stories
stories
YES
2308.2.2 Bearing wall floor to floor height
ft
YES
2308.2.3.1 Average DL
psf
YES
2308.2.3.2 Floor Live Loads
psf
NO
2308.2.3.3 Ground Snow Load
psf
YES
2308.2.4 Wind speed
mph
YES
2308.2.5 Truss Span
ft
YES
1616.6.1 Simplified Analysis Requirements
YES
YES
1. Does Building meet light frame construction criteria ?
2. Is building of any other construction with flexible diaphragms at
every level as defined in section 1602 ?
Building may use Simplified Analysis Method
Design Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE 9/15/2003
REXBURG, IDAHO
Page 4
Type
Fb psi
Fv psi
E psi
LVL
2600
285
1900000
GLB
2400
190
1800000
DF
1300
95
1900000
Beam 1
Hall Joist
Type
DF
Fb psi
1300
Fv psi
95
5
1.33
E psi
1900000
Span =
ft
Tributary Area =
ft
0
Loads
Point Load =
Ibs
0
40
15
Snow
psf
Uniform Load =
0
Ibs /ft
Live Load
psf
53.2
Ibs /ft
Dead Load
psf
19.95
Ibs /ft
Moment
Live Load Moment =
166
lb -ft
=
1995
lb-in
Dead Load Moment =
62
lb-ft
=
748
lb-in
Section Modulus Required
=
2.11
in3
1.5
5.5
Section Width =
in.
Section Depth =
in.
Section Modulus Provided =
7.6
in3
OK
Moment of Ineritia Provided =
20.8
in4
Deflection
Live Load =
0.01
in.
L/360
0.17
in.
OK
Dead Load =
0.01
in.
Total =
0.02
in.
L/240
0.25
in.
OK
Horizontal
Shear
fv =
33
psi
OK
FV =
95
psi
Allowable
Reaction =
182.875
lbs
Use
1.5
X
5.5
DF
Deign Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE 9/15/2003
REXBURG, IDAHO
Page 1
Type
Fb psi
Fv psi
E psi
LVL
2600
285
1900000
GLB
2400
190
1800000
DF
1300
95
1900000
Beam 2
Bearing Wall Window Header
Type
DF
Fb psi
1300
Fv psi
95
4
20
E psi
1900000
Span =
ft
Tributary Area =
ft
0
Loads
Point Load =
Ibs
35
0
15
Snow
psf
Uniform Load =
700
Ibs /ft
Live Load
psf
0
Ibs /ft
Dead Load
psf
300
Ibs /ft
Moment
Live Load Moment =
1400
lb-ft
=
16800
lb-in
Dead Load Moment =
600
lb-ft
=
7200
lb-in
Section Modulus Required
=
18.46
in3
3
9.25
Section Width =
in.
Section Depth =
in.
Section Modulus Provided =
42.8
in3
OK
Moment of Ineritia Provided =
197.9
in4
Deflection
Live Load =
0.01
in.
L/360
0.13
in.
OK
Dead Load =
0.00
in.
Total =
0.02
in.
L/240
0.2
in.
OK
Horizontal
Shear
fv =
108
psi
OK
FV =
109.25
psi
Allowable
Reaction =
2000
Ibs
Use
3
X
9.25
DF
Deign Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE 9/15/2003
REXBURG, IDAHO
Page 2
Foundation Design
40
20
9
8
8
Allowable Bearing Capacity
1500
psf
Max Roof Span =
ft
35
40
15
15
0
15
Max Floor Span =
ft
Snow Load
psf
Wall Height =
ft
Floor Live Load
psf
Stem Wall Height =
ft
Wall Dead Load
psf
Stem Wall Width =
in.
Roof Dead Load
psf
Brick Dead Load
psf
Floor Dead Load
psf
Exterior Bearing Walls - F1
Proposed
Footing
24
10
Roof Loads
1000
Ibs /ft
Width
in
Floor Loads
550
Ibs /ft
Depth
in
Wall Load
135
Ibs /ft
Stem Wall Load
800
Ibs /ft
Footing Load
250
Ibs /ft
Total
2735
Ibs /ft
Bearing Pressure =
1368
psf
OK
Reinforcing Requirements
1
Min Reinforcing Factors
Footing
0.002
Stem Wall
Vertical
0.0012
#4
0.2
Horizontal
0.002
Reinforcing Bar
in *in
Footing
Continuous Reinforcing Count
2
bars
Stem Wall
Continuous Reinforcing Count
8
bars
Vertical - Reinforcing Spacing
18
in.
Deign Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE
REXBURG, IDAHO
Page 1
9/15/2003
Foundation Design
0
28
9
8
8
Allowable Bearing Capacity
1500
psf
Max Roof Span =
ft
35
40
15
15
0
15
Max Floor Span =
ft
Snow Load
psf
Wall Height =
ft
Floor Live Load
psf
Stem Wall Height =
ft
Wall Dead Load
psf
Stem Wall Width =
in.
Roof Dead Load
psf
Brick Dead Load
psf
Floor Dead Load
psf
Interior Bearing Walls - F2
Proposed
Footing
16
10
Roof Loads
0
Ibs /ft
Width
in
Floor Loads
770
Ibs /ft
Depth
in
Wall Load
135
Ibs /ft
Stem Wall Load
800
Ibs /ft
Footing Load
167
Ibs /ft
Total
1872
Ibs /ft
Bearing Pressure =
1404
psf
OK
Reinforcing Requirements
Min Reinforcing Factors
Footing
0.002
Stem Wall
Vertical
0.0012
#4
0.2
Horizontal
0.002
Reinforcing Bar
in *in
Footing
Continuous Reinforcing Count
2
bars
Stem Wall
Continuous Reinforcing Count
8
bars
Vertical - Reinforcing Spacing
18
in.
Deign Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE
REXBURG, IDAHO
Page 2
9/15/2003
Shear Wall Analysis - Short Wall
Wind Load =
22 psf
12
8
67
1072
Roof Height =
ft
Wall Height =
ft
Length of Long Wall =
ft
Area at Mid Height of Wall =
ft^2
Wind Force =
23584
Ibs
70
Shear Wall Length
ft
Shear /ft in Wall @ Mid Height
337
Ibs /ft
Provide 1/2" APA rated sheathing with 8d nails at 4" o.c.
at panel edges and 12" o.c. in the field. Blocking is required
0.09
Seismic Analysis
Seismic Multiplier =
Width
39
Length
71
Load
24
(includes snow)
Weight
Roof Dead Load
66456
Ibs
67
35
Long Wall Length
ft
Short Wall Length
ft
Height
8
Length
Load
15
Weight
Wall Dead Load
204
12240
Ibs
Seismic Force @ Mid Height of Wall
7083
Ibs
70
Shear Wall Length
ft
Shear per ft in Wall @ Mid Height
101
Ibs /ft
OK
Provide 1/2" APA rated sheathing with 8d nails at 4" o c.
at panel edges and 12" o.c. in the field. Blocking is required
' Deign Intelligence, LLC
3685 W Hwy 33
Rexburg, Idaho 83440
LEONARDSON'S INSURANCE
REXBURG, IDAHO
Page 1
9/15/2003