HomeMy WebLinkAboutCO & DOCS - 03-00016 - Gringo's Restaurant - New BuildingCERTIFICATE OF OCCUPANCY City of Rexburg Department of Building Inspection Building Permit No: R- o3 -o4 -17 Applicable edition of code: International Building Code 2000 ❑ International Residential Code 2000 Site address: 43 South Center Use and occupancy: Commercial Type of construction: Wood Frame Design occupant load: 161 Sprinkler System required: ❑ Yes ❑ No Name and address of owner: ZolMic, LLC 175 North 1st East Rexburg, ID 8344 Contractor: ZoCo Properties, LLC Special conditions: Occupancy: Full ❑ Partial ❑ Temporary This Certificate, issued pursuant to the requirements of Section 109 of the International Building Code, certifies that, at the time of issuance, this 6ui[bing or that portion of the 6uifbing that w rr as /I inspected on the bate [isteb was f ounb to be in compliance with the req requirements of the co be for th group a �nA Aivi.cinn of occ1 pane am?? the use for wbicV1 the � v vrr tv�wv of .n vvv.. ... /.. J ..... ' � �.. . .. .. - -"'�' -- " - �/ - -'- the - - - � propose occupancy was cLassi f ieb. Date: October 16, 2003 (10: C.O. Issued by: Building Official There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or an . rtion eof 40 until the Buildi Officjalhas revie d and approved said future change ---_ Water Department : '! 0 Fire Departmen State of Idaho Electrical Department - (208 - 356-4830) ❑ Merlin Webster • • BUILDING PERMIT APPLICATION REXBURG, ID D A T E / Y . ` -/ 153 NO.fl %3'a -- I '7 THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS. OWNER 1 , L LC, BUILDER I■ Co *Pro pt ■.e STRUCTURE: XNEW O REMODEL FOUNDATION BASEMENT *CONCRETE ❑ PARTIAL O MASONRY FULL ❑ OTHER CrNO FLOORS J WOOD O CONCRETE ❑ OTHER EXT. WALLS WOOD O MASONRY O CONCRETE ❑ VENEER O METAL )$;STUCCO INT. WALLS CEILING ROOF )(WOOD Al:WOOD ❑ MASONRY O DRYWALL QUI CONCRETE O PLASTER *DRYWALL ❑ TILE ❑ PLASTER ❑ ACOUSTIC O TILE ❑ OPEN ❑ BUILT UP. O WOOD SH. ❑ COMP. SH. TILE ROLL ROOF. O METAL HEAT *GAS CI OIL O COAL O FIREPLACE O ELECTRIC O RESIDENCE FOOTINGS CONCRETE MASONRY ❑ OTHER COMM. ❑ EDUCATIONAL O GOVT O RELIGIOUS ❑ FENCE O PATIO ❑ CARPORT ❑ GARAGE ❑ AWNING This permit is issued subject to the regulations contained in the Uniform Building Code and Zoning Regulations of Rexburg, and it is hereby agreed that the work to be done as shown in the plans and specifications will be completed in accordance with the regulations pertaining and applicable thereto: The issuance of the permit does not waive restrictive covenants. REMARKS: VALUE FEE PAID BUILDING INSPECTOR ( - ' 354 `: 59 DEPARTMENT OF BUILDING & ZONING F ❑ CASH O CHECK JOB ADDRESSf j `) ° `�. 4 ," PHONE DESIGNER ❑ RENEWAL ARCHITECT C) ❑ ADDITION 0 REPAIR DATE ADDRESS WHITE - Owner's Copy CANARY - Building Department's Copy PINK - Assessor's Copy GOLDENROD - Inspector • O FIRE DAMAGE INSULATED WALLS CEILING ❑ FLOORS O PERIMETER APPLICATION FOR BUILDING PERMIT CITY OF REXBURG, IDAHO Date of Application 3/ 1`/0_3 Permit No. _6 3 - ° 1 OWNER Name to \.M; �2.L Site Address 4 50 Lev er Mailing Address V s- :x S� City /State /Zip g.� sr / :0-L0 - rivD Telephone/Fax/Mobile C2-0 - - � 0 CONTRACTOR Name 20 C P, Qs LL C Mailing Address 1" 1J- 1, a w. a_ v \ City /State /Zip 124. k Telephone/Fax/Mobile (2 c 3S - `k PROJECT INFORMATION DEPARTMENT APPROVAL Property Zone: C 13() Is existing use compatible with zoning, (screening parking, etc) Ye 5 When was this building last occupied /V&A) &A) Architect/ Engineer Firm . CC (34 p «v) c� Plan Name Subdivision J Lot Block Circle One Residents. Commerc'. Educational Government Remodel Other Circle One New House Addition/Remodel to House Chew Commercial ) Commercial Remodel Circle One Basement: None/ Finished / nfinishe� i Other: None/ Patio/ Carport/ Awning N/A Lot Square Footage 5.5-0C) Lot Width 6 5 Square Feet "'/'6 Garage Square Feet NA Number of Stories r Height of Building Al. 10 What will structure be used for: Home Home Business Apartment C m ia.. Other Will there be an apartment? 4/0 If so, how many units Total Estimated Cost / V Are you in a flood plain p Signature of Applicant Code Zone Building Type CITY OF REXBURG 1 PAID CASH $ HECK APR 1 6 2003 Building Permit Fees Plan Check Fees Plumbing Permit Fees Lf / S Digging Permit Fees Water & Sewer Fees 3 71, Front Footage Fee TOTAL $ Signature of Inspector Issued by OWNER Name L t:: MI C , LL C• Address a ... �. 1 , ,. Tel. ' I`LL =i Lot Bik Add. Name Bath Tubs Showers Laundry Trays Wash Basin Toilet Slop Sinks Kitchen Sinks Floor Drain Drinking Fountains Water Softeners Dish Washing Mach. Clothes washer PWMBER Address Tel. NATURE OF INSTALLATION Use CITY OF REXBURG APPLICATION FOR PLUMBING PERMIT Septic Tank 'Hater Ong Sewer FEES Plumbing Permit $ Sewer Inspection $ Inspection of Pipe $ Inspection of Fixtures $ $ $ TOTAL $ Received: Date By NSPECTOR'S RECORD N IPTION OF WORK Urinal Sink Trap Water Heater Lawn Sprinklers 1 CITY OF REXBUR PAID CASH $ CHECK $ APR 1 6 2003 Rough Plumbing Server Other Finish Plumbing WSP NAME Excavation & Earthwork: vl, v� -z,r- �.n5��rv� -}� vtA_ Concrete: � �. �v o CO114' 0 Masonry: \ cc v��' Roofing: v►� � n c v. . Insulation: 1;M Wet+ Drywall: - 4y I W.xl -vvk S Painting: Floor Coverings: n Plumbing: r &, t �vr %VAl &\ Heating: �l v z-O Electrical: 'L.,,zxv- )3A. Ete_c ---Vv'; SPECIAL CONSTRUCTION (Manufacturer or Supplier) Roof Trusses: Sm 1,6e54 — 1'3" - T_ Floor / Ceiling Joists: Cabinets: Siding /Exterior Trim: SA- y Other: SUBCONTRACTOR LIST )J _t\ Otis „�5 REQUEST FOR A CONDITIONAL BUILDING PERMIT FOR PARTIAL BUILDING CONSTRUCTION TO: Building Official for the City of Rexburg Pursuant to the provisions of the Uniform Building Code, the undersigned requests that a building permit be issued for: Footings and Foundations only at: Gringos Mexican Restaurant 23 South Center Rexburg, Idaho 83440 Acknowledgment is made that the plans for the complex are not complete and that final approval of the building will not be given until the final plans have been approved. We recognize that proceeding with partial construction at this time is entirely at the risk of the Architect/Owner with there being no assurance that the final Certificate of Occupancy for the entire building or structure will be granted. We further absolve the City of Rexburg and officers and employees thereof, of all responsibility for the issuance of a partial permit and further agree that any work performed under this permit will be removed or otherwise corrected to be in accord with the requirements of the final approved plans when a permit for the entire building or structure is finally granted. Dated: March 24, 2003 Approved: 24 March 2003 CITY 0 �;.� XBURG By J hn illar REXB UR G- MgDISON COUNTY EMERGENCY SERVICES 26 NORTH CENTER STREET REXBURG, IDAHO 83440 208 - 359 -3010 208 -359 -3006 FAX 2000 International Fire Code Plan Date: 4 -16 -03 Plan Review Review Date: 4 -29 -03 Building Name: Building Address: NEAR 23 SOUTH CENTER Stories: ONE Type of Construction: V -B Occupancy Classification: A -2, S -1 Existing Floor Area: N/A New Construction Floor Area: 9600 SQUARE FEET 1. Required Fire Flow (Appendix B): 2750 GPM/TWO HOURS Comments: REQUIRED FIRE FLOW MAY BE REDUCED UP TO 75% IF AN APPROVED FIRE SPRINKLER SYSTEM IS INSTALLED. 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: MAIN AND CENTER, MAIN AND CARLSON, CARLSON AND COLLEGE AVE. Fire Hydrant Flows: OK Fire Flow Test Location: SAME AS ABOVE Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: YES Fire Hydrant Location Acceptable: YES Water Supply Comments: OCCUPANCY CURRENTLY HAS THREE FIRE HYDRANTS WITHIN 450 FEET 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: X Length: X Surface: X Complete Road Acceptable: YES Comments: NONE 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: NOT SHOWN Type provided acceptable: NOT SHOWN Comments: OCCUPANCY REQUIRES A CLASS "K" EXTINGUISHER IN KITCHEN AREA IN ADDITION TO TWO ADDITIONAL 2A10BC EXTINGUISHERS IN BUILDING. 6. Automatic fire extinguishing systems (Section 903) Required: NO Type of system being installed: Sprinkler system monitoring (Section 907) required: Comments: 7. Standpipes (Section 905) required: NO Type required: Comments: 8. Ventilating hood and duct fire extinguisher system (Section 609) required: YES Type being provided: NOT SHOWN Automatic fuel shut -off required: YES Portable fire extinguisher shown: NOT SHOWN Comments: PLEASE PROVIDE SIZE, TYPE, MANUFACTURER, ETC. OF HOOD SYSTEM TO BE INSTALLED. 9. Fire alarm systems (Section 907) required: NO Type of system required: Manual: Automatic: Both: Type of system being provided: Manual: Automatic: Both: Components of system shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: 10. Other corrections that are required by special occupancy or conditions: PLANS SUBMITTED SHOW A NARROWING OF THE EGRESS PATH NEAR THE HOSTESS STATION THAT MAY REDUCE TOTAL OCCUPANCY LIMITS IN DINING AREA. Plans as submitted are acceptable: NO Plans checked by: CHRIS HUSKINSON Date: 4 -29 -03 Please furnish comments back to the plan reviewer in the following manner: Written Comments: New Plans: ****THIS PLAN REVIEW IS INCOMPLETE. INSPECTOR STILL WAITING FOR SEATING ARRANGEMENT DRAWINGS FROM OWNER FOR COMPLETE OCCUPANCY LIMITS.******* 2000 International Fire Code Plan Review ex STATE OF IDAHO REXB UR G- MADISON COUNTY EMERGENCY SERVICES 26 NORTH CENTER STREET REXBURG, IDAHO 83440 208 -359 -3010 208 -359 -3006 FAX Plan Date: 4 -16 -03 Review Date: 4 -29 -03 REVISED: 6 -7 -03 P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359 -3020 Fax (208) 359 -3022 e -mail rexburg@srv.net Building Name: GRINGO'S RESTAURANT Building Address: NEAR 23 SOUTH CENTER Stories: ONE Type of Construction: V -B Occupancy Classification: A -2, S -1 Existing Floor Area: N/A New Construction Floor Area: 9600 SQUARE FEET 1. Required Fire Flow (Appendix B): 2750 GPM/TWO HOURS Comments: REQUIRED FIRE FLOW MAY BE REDUCED UP TO 75% IF AN APPROVED FIRE SPRINKLER SYSTEM IS INSTALLED. 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: MAIN AND CENTER, MAIN AND CARLSON, CARLSON AND COLLEGE AVE. Fire Hydrant Flows: OK Fire Flow Test Location: SAME AS ABOVE N Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: YES Fire Hydrant Location Acceptable: YES Water Supply Comments: OCCUPANCY CURRENTLY HAS THREE FIRE HYDRANTS WITHIN 450 FEET 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: X Length: X Surface: X Complete Road Acceptable: YES Comments: NONE 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: NOT SHOWN Type provided acceptable: NOT SHOWN Comments: OCCUPANCY REQUIRES A CLASS "K" EXTINGUISHER IN KITCHEN AREA IN ADDITION TO TWO ADDITIONAL 2A1OBC EXTINGUISHERS IN BUILDING. 6. Automatic fire extinguishing systems (Section 903) Required: NO Type of system being installed: Sprinkler system monitoring (Section 907) required: Comments: 7. Standpipes (Section 905) required: NO Type required: Comments: 8. Ventilating hood and duct fire extinguisher system (Section 609) required: YES Type being provided: NOT SHOWN Automatic fuel shut -off required: YES Portable fire extinguisher shown: NOT SHOWN Comments: PLEASE PROVIDE SIZE, TYPE, MANUFACTURER, ETC. OF HOOD SYSTEM TO BE INSTALLED. 9. Fire alarm systems (Section 907) required: NO Type of system required: Manual: Automatic: Both: Type of system being provided: Manual: Automatic: Both: Components of system shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: 10. Other corrections that are required by special occupancy or conditions: PLANS SHOW SEATING WITH A TOTAL OF 160 SEATS. WAITING AREA WILL HANDLE UP TO 16 PEOPLE, KITCHEN AREA DESIGNED FOR 6 PEOPLE. MISC. AREAS ON MAIN LEVEL WILL ALLOW UP TO 8 PEOPLE. TOTAL OCCUPANCY OF ENITRE MAIN LEVEL IS 190. DINING AREA TO BE POSTED WITH MAXIMUM OCCUPANCY OF 160. STILL WAITING FOR SUBMITTALS ON HOOD SYSTEM. Plans as submitted are acceptable: WITH ABOVE ITEMS COMPLETED Plans checked by: CHRIS HUSKINSON Date: 6 -06-03 Please furnish comments back to the plan reviewer in the following manner: Written Comments: New Plans: 5/1/2003 Scott Spaulding Design Intelligence 3685E Hwy. 33 Rexburg, Idaho 83440 Dear Scott, Val Christensen Building Official cc Stephen Zollinger John Millar Chris Huskinson STATE OF IDAHO www.ci.rexburg.id.us p �� y P.O. Box 280 011 Ul urq 12 North Center Street Rexburg, ldaho 83440 Phone (208) 359 -3020 Fax (208) 359 -3022 e -mail rexburg @ci.rexburg.id.us I have reviewed the Gringos Restaurant drawings that you have provided me and have identified the following discrepancies: 1. A site plan must be provided. I have attached a copy of the site plan requirements to the back of this document. The parking lot must be designed to City of Rexburg standards. There will need to be an ADA compliant van accessible handicap parking place. 2. I will need information for the future installation of any cooking hoods. 3. Provide exit lights and emergency lights as per code. 4. Occupancy limits must be posted near the exits. 5. The Fire Department has reviewed the plans. I have attached a copy of their report to the back of this document. Please provide the necessary information they have requested. Please return two sets of plans. Let me know if I can be of any further assistance. If you have any questions, please give me a call at 359 -3020 ext. 324. Sincerely, �yD Cll m 2eQifI STATE OF IDAHO P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359 -3020 Fax (208) 359 -3022 e -mail rexburg @srv.net Site Plan Checklist File Number: Applicant Information Applicant: Phone: ❑ Owner ❑ Purchaser ❑ Lessee Applicant's Address: Zip: Recorded Owner: Phone: Recorded Owner Address: FAX: Development Information Project Name: Property Address: ❑ 1. Site plan must be drawn to scale, be legible and also be submitted electronically if possible. ❑ 2. Adjoining streets labeled. ❑ 3. Right -of -way location and width, curb to curb widths and sidewalk location. ❑ 4. Building location, sq footage and dimensions, with distance to property lines. ❑ 5. Show existing and proposed easements. ❑ 6. Existing utilities (waterlines, sanitary sewer lines, manholes, storm drains). ❑ 7. Proposed utilities including tie in location to existing services and new easements. ❑ 8. Proposed storm drain and sanitary sewer elevations (for pipe inverts at manholes and catch basins). ❑ 9. Storm drainage plan for parking lot and roof areas, with calculations. ❑ 10. Fire hydrants and fire suppression lines (including tie to City lines). ❑ Sprinkled ❑ Not Sprinkled ❑ 11. Parking (including parking lot, drainage arrows, dimension of lot, distance between rows, and total numbers). ❑ 12. Landscaping (type and total area, including dimensions). ❑ 13. Trash facilities. ❑ 14. North Arrow ❑ 15. Drawing to Scale, including a graphic scale (11 1/2 x 17" paper if possible). ❑ 16. Proposed street improvements (curb, gutter, sidewalk, pavement, etc.) ❑ 17. Legal description of proposed building site included. ❑ 18. Percent of lot covered by building or paving calculated. ❑ 19. Show 10% snow storage area. ❑ 20. Distance of entrances from street corner indicated. ❑ 21. Current Vicinity Map. (8 1/2 x 1 1 ") at 1" = 300' scale, showing location of the property. NOTE: SITE PLANS MUST BE COMPLETE AND SUBMITTED FOR REVIEW BEFORE THE PROJECT WILL BE PLACED ON THE PLANNING & ZONING AGENDA. *********-*******************************-******-* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * ** REXBURG - MADISON COUNTY EMERGENCY S ER VI CE S 26 NORTH CENTER STREET REXBURG, IDAHO 83440 208-359-3010 208- 359 -3006 FAX 2000 International Fire Code Plan Date: 4 -16-03 Plan Review Review Date: 4-29-03 Building Name: GRINGO'S RESTAURANT Building Address: NEAR 23 SOUTH CENTER Stories: ONE Type of Construction: V B Occupancy Classification: A -2, S -1 New Construction Floor Area: 9600 SQUARE FEET 1. Required Fire Flow (Appendix B): 2750 GPM/TWO HOURS Comments: REQUIRED FIRE FLOW MAY BE REDUCED UP TO 75% IF AN APPROVED FIRE SPRINKLER SYSTEM IS INSTALLED. 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: MAIN AND CENTER, MAIN AND CARLSON, CARLSON AND COLLEGE AVE. Fire Hydrant Flows: OK Fire Flow Test Location: SAME AS ABOVE Fire Flow Supplied By: FD Other Approved Water Source: NONE Water Supply Acceptable: YES Fire Hydrant Location Acceptable: YES Existing Floor Area: N/A Water Supply Comments: OCCUPANCY CURRENTLY HAS THREE FIRE HYDRANTS WITHIN 450 FEET 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: X Length: X Surface: X Complete Road Acceptable: YES Comments: NONE 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: NOT SHOWN Type provided acceptable: NOT SHOWN Comments: OCCUPANCY REQUIRES A CLASS "K" EXTINGUISHER IN KITCHEN AREA IN ADDITION TO TWO ADDITIONAL 2A1OBC EXTINGUISHERS IN BUILDING. 6. Automatic fire extinguishing systems (Section 903) Required: NO Type of system being installed: Sprinkler system monitoring (Section 907) required: Comments: 7. Standpipes (Section 905) required: NO Type required: Comments: 8. Ventilating hood and duct fire extinguisher system (Section 609) required: YES Type being provided: NOT SHOWN Automatic fuel shut -of required: YES Portable fire extinguisher shown: NOT SHOWN Comments: PLEASE PROVIDE SIZE, TYPE, MANUFACTURER, ETC. OF HOOD SYSTEM TO BE INSTALLED. 9. Fire alarm systems (Section 907) required: NO Type of system required: Manual: Type of system being provided: Manual: Components of system shown: Smoke Detectors: Manual Pull Station: Sounding Devices: Door Holders: Duct Detectors: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: Both: Both: Heat Detectors: Visual Devices: Flow Alarm: Automatic: Automatic: 10. Other corrections that are required by special occupancy or conditions: PLANS SUBMITTED SHOW A NARROWING OF T#: EGRESS PATH NEAR STATION THAT MAY REDUCE TOTAL OCCUPANCY LIMITS IN DINING AREA. Plans as submitted are acceptable: NO Plans checked by: CHRIS HUSKINSON Date: 4 - 29 - 03 Please furnish comments back to the plan reviewer in the following manner: Written Comments: New Plans: ****THIS PLAN REVIEW IS INCOMPLETE. INSPECTOR STILL WAITING FOR SEATING ARRANGEMENT DRAWINGS FROM OWNER FOR COMPLETE OCCUPANCY LIMITS.******* Designed :,, : cott Spaulding, P.E. Checked By: Date: ∎4 Date: , Date: April 16, 2003 Subject: Gringo's Restaurant, Rexburg, Idaho Customer: Steven Zollinger Design Intelligence, LLC Engineering Calculations Summary This analysis uses the Design Criteria required by the local jurisdiction and the IBC 2000 as the basis for the calculations. Materials: Dimensional Lumber — NDS 1997 design values Concrete: 2500 psi @ 28 days Reinforcing Steel - #4 and smaller Grade 40, #5 and larger Grade 60 Assumptions: IBC 2000 — Foundations designed for Max Brg Pressure of 1500 psf increased for depth Design Loads: Roof Live Load (min) — 20 psf during construction Ground Snow load = 50 psf, Roof Snow load= 35 psf Snow Load Importance Factor — 1.0 Snow Exposure Factor — 0.9 Wind = 90 mph, Exposure B Wind Importance Factor — 1.0 Wind Exposure = B Seismic Design Category — D1 Seismic Use Group - 1 References: IBC 2000 Customer Sketches TrusJoist MacMillian Design Guides Summary: All beam sizes and footing sizes are noted on the drawings. These calculations and included details are for this location and customer only and not to be reused in any manner without the written consent of Design Intelligence. Design Intelligence, LLC GRINGO'S 4/16/2003 3685 W Hwy 33 STEVE ZOLLINGER Rexburg, Idaho 83440 Design Parameters Snow Load: Snow Loads Roof Pitch Roof Pitch Roof Pitch Wind Simplified Method Horizontal Loads Transverse < 5:12 5:12 > 5:12 Longitudinal Vertical Loads Transverse < 5:12 5:12 > 5:12 Longitudinal Maximum Hori Transverse < 5:12 5:12 > 5:12 Rise 3 -'- 4 6 Roof Pitch 7 Roof Pitch 81 Roof Pitch 10 Roof Pitch 12 Design Wind Speed 90 mph Importance Factor 1 Exposure B' End Zone Wall Roof 12.8 17.8 14.4 12.8 End Zone Windward -15.4 12.1 10.7 Run 12 12 12 12 12 .- 12 5 psf Section 1609.6 Applicable loads are shown in bold letters. Roof Leeward Roof -6.7 - 4.7 9.9 - 6.7 -15.4 1E 9.8 -10.7 -8.8 -8.8 -8.8 -7.5 -10.1 -8.1 Reduction 0.0 psf 0.0 psf 2.5 psf 3.8 psf 5.1 psf 7.4 psf 9.4 psf Interior Zone Wall Roof 8.5 11.9 11.5 8.5 Interior Zone Windward -10.7 -10.7 4.8 -10.7 Zone 1 7.2 8.8 9.1 Roof Leeward Roof Page 1 -4 -2.6 7.9 -4 - 6.8 -8.1 - 7.5 - 6.8 4 -5.8 - 7.5 -6.8 Use 35.0 psf 35.0 psf 32.5 psf 31.2 psf 29.9 psf 27.6 psf 25.6 psf Winward Overhang End Zone -21.6 -21.6 -5.1 -21.6 Interior Zone -16.9 -16.9 -5.8 -16.9 Longitudinal 9.8 -7.5 7.2 -5.8 Component and Cladding Design Wind Pressures - Table 1609.6.2.1(2) Roof Zone Area < 5:12 5:12 > 5:12 1 10 10 -14.6 10 -13.3 13.3 -14.6 1 20 10 -14.2 10 -13 13 -13.8 1 50 10 -13.7 10 -12.5 12.5 -12.8 1 100 10 -13.3 10 -12.1 12.1 -12.1 2 10 10 -24.4 10 -28.2 13.3 -17 2 20 10 -21.8 10 -25.6 13 -16.3 2 50 10 -18.4 10 -22.1 12.5 -15.3 2 100 10 -15.8 10 -19.5 12.1 -14.6 3 10 10 -36.8 10 -28.2 13.3 -17 3 20 10 -30.5 10 -25.6 13 -16.3 3 50 10 -22.1 10 -22.1 12.5 -15.3 3 100 10 -15.8 10 -19.5 12.1 -14.6 Wall 4 10 14.6 -15.8 4 20 13.9 -15.1 4 50 13 -14.3 4 100 12.4 -13.6 5 10 14.6 -19.5 5 20 13.9 -18.2 5 50 13 -16.5 5 100 12.4 -15.1 Roof Overhang Component and Cladding Design Wind Pressures - Table 1609.6 2.1(3) Zone Area < 5:12 5:12 > 5:12 2 10 -21 -27.2 -24.7 2 20 -20.6 -27.2 -24 2 50 -20.1 -27.2 -23 2 100 -19.8 -27.2 -22.2 3 10 -34.6 -45.7 -24.7 3 20 -27.1 -40.5 -24 3 50 -17.3 -33.6 -23 3 100 -10 -28.4 -22.2 1609.6.2.1(4) Height and Exposure Adjustment Coefficient = 1' Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 GRINGO'S 4/16/2003 STEVE ZOLLINGER Page 2 Design Intelligence, LLC GRINGO'S 4/16/2003 3685 W Hwy 33 STEVE ZOLLINGER Rexburg, Idaho 83440 Seismic Reference Code - IBC 2000 1615.1.2.(1) 1615.1.2(2) 1615.1 1615.1 Site Class A - Hard Rock Site Class B - Dense Soil or Soft Rock Site Class C - Stiff Soil Fite Glass D Site Class 1615.1.2 1615.1.2 1615.1.3 Fa Fv Ss SI SMS = FaSs SM1 = FvS1 Design Spectral Resp Accel SDS = 2/3 *SMS SDI = 2 /3 *SMI 1616.2 Seismic Use Group Group 1- Non - Essential Seismic Response Coefficient Basic Fundamental Period Steel Moment Resisting Frame All Other Building Systems Building Height Approximate Fundamental Period Ta = Ct *hn ^3/4 = 0.281 sec Site Class Cs = SDS /(R /I) = Max Cs = SDI /(R /I)T = Min Cs = 0.044SDS *I = 20 ft 51 g 164 g Design Seismic Response Coefficient Values for Ss, S1, Fa and Fv are taken from Code Control CD using Zip Code A 0.40864 0.13152 0.273789 0.088118 Table 1616.3(1) Table 1616.3(2) B 0.5108 0.1644 1617.6 (Table 1617.6) Response Modification Factor R = 1616.2 (Table 1604.5) Occupancy Importance Factor I = Reinforced Concrete Moment Resisting Frame 0.0456 0.0041 0.0120 B 0.342236 0.110148 1616.3 Seismic Design Category Ct 0.035 0.03 0.02 Table 1617.4.2 Cu = Rigid Bldg 0.0570 0.0052 0.0151 Page 3 C Fa 0.8 1 1.2 C D 0.61296 0 674256 0.27948 0.4106832 0.1872516 1.49' Fv 0.8 1 1.7 752 0.0684 0.0088 0.0105 0.0181 - 0x199' Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 GRINGO'S 4/16/2003 STEVE ZOLLINGER Page 4 Site Class A B C D Cs = 0.0120 0.0151 0.0181 0.0199 0.0199 0.09035 1617.4.1 Equiv Lateral Force Method V = CsW = W 1617.5.1 Simplified Approach V = 1.2 *(SDS /R) *W = W Determine Method of Seismic Analysis Light Framing Construction Criteria 1 2308.2.1 Building stories stories YES 2308.2.2 Bearing wall floor to floor height 12 ft NO 2308.2.3.1 Average DL 15 psf YES 2308.2.3.2 Floor Live Loads 50 psf NO 2308.2.3.3 Ground Snow Load 35 psf YES 2308.2.4 Wind speed 90 : mph YES 2308.2.5 Truss Span 0 ft YES 1616.6.1 Simplified Analysis Requirements 1. Does Building meet light frame construction criteria ? NO 2. Is building of any other construction with flexible diaphragms at every level as defined in section 1602 ? YES Building may use Simplified Analysis Method Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 GRINGO'S 4/16/2003 STEVE ZOLLINGER Page 4 Design Intelligence, LLC GRINGO'S 4/16/2003 3685 W Hwy 33 STEVE ZOLLINGER Rexburg, Idaho 83440 Type LVL GLB DF Beam Type GLB Span = Fb psi 2600 2400 1300 Roof Support Fb psi 2400 Tributary Area = 15 Loads Snow Live Load Dead Load Moment Live Load Moment = Dead Load Moment = 5 psf 0 psf 15 psf Section Modulus Required Fv psi Fv psi 20 Width = 6,75 in. Section Depth = 15 in. Section Modulus Provided = Moment of Ineritia Provided = Deflection Live Load Dead Load = Total = Horizontal Shear FV = 111 218.5 psi psi 26250 11250 0.55 0.24 0.79 285 190 95 E psi 1900000 1800000 1900000 E psi 90 1800000 lb-ft in. 253.1 1898.4 OK Allowable Use Point Load = 0 Ibs Uniform Load = in3 in4 L/360 L/240 187.50 6.75 in3 Page 1 315000 135000 0.67 Reaction = X lb-in lb-in in. 15 525 0 225 Ibs /ft Ibs /ft Ibs /ft OK OK OK GLB 7500 lbs Design Intelligence, LLC GRINGO'S 4/16/2003 3685 W Hwy 33 STEVE ZOLLINGER Rexburg, Idaho 83440 Type LVL GLB DF Beam 2 Type GLB Span = Tributary Area = Loads Snow Live Load Dead Load 15 psf Moment Fb psi Live Load Moment = Dead Load Moment = Section Modulus Required Section Width = Section Depth = Fb psi Fv psi E psi 2400 190 1800000 35 psf 0 psf Fv psi Section Modulus Provided = Moment of Ineritia Provided = Deflection Live Load = Dead Load = Total = Horizontal Shear FV = 152 218.5 psi psi 20 ft 22.5 ft 39375 16875 0.62 0.27 0.89 E psi 1900000 1800000 1900000 lb-ft lb-ft 6.75 -in. 16.5' in. m . m . OK 306.3 2526.8 Allowable Use Point Load = 0 Ibs Uniform Load = in3 in4 U360 U240 281.25 6.75 in3 Page 2 472500 202500 0.67 Reaction = X lb-in lb-in m . 16.5 787.5 0 337.5 Ibs /ft Ibs /ft Ibs /ft OK OK OK GLB 11250 Ibs Type Fb psi Fv psi E psi LVL 2600 285 1900000 GLB 2400 190 1800000 DF 1300 95 1900000 Beam 3 Floor Support Type GLB Fb psi 2400 Fv psi 190, E psi 1800000 Span = 20 ft Tributary Area = 1 ft Loads Point Load = 0 Ibs Snow 0 psf Uniform Load = 0 lbs/ft Live Load 70 15 psf (includes partition load) 1050 lbs/ft Dead Load psf 225 lbs/ft Moment Live Load Moment = 52500 lb-ft = 630000 lb-in Dead Load Moment = 11250 lb-ft = 135000 lb-in Section Modulus Required = 318.75 in3 Section Width = 6.75 in. Section Depth = 18 in. Section Modulus Provided = 364.5 in3 OK Moment of Ineritia Provided = 3280.5 in4 Deflection Live Load = 0.04 in. L/360 0.67 in. OK Dead Load = 0.14 in. Total = 0.18 in. L/240 1 in. OK Horizontal Shear fv = 157 psi OK FV = 190 psi Allowable Reaction = 12750 lbs Use 6.75 X 18 GLB Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 GRINGO'S 4/16/2003 STEVE ZOLLINGER Page 3 Design Intelligence, LLC GRINGO'S 4/16/2003 3685 W Hwy 33 STEVE ZOLLINGER Rexburg, Idaho 83440 1300 Floor Support Type LVL GLB DF Beam 4 Type GLB Span = Tributary Area = 22.5 Loads Snow Live Load Dead Load Moment Live Load Moment = Dead Load Moment = Section Modulus Required Section Width = Section Depth = Section Modulus Provided = Moment of Ineritia Provided = Deflection Live Load = Dead Load = Total = Fb psi P Horizontal Shear Fb psi Fv psi 2400 189 190 2600 2400 Fv psi 0 psf 70 psf 15 psf psi psi 20._. 78750 16875 0.02 0.11 0.13 E psi 285 1900000 190 1800000 1900000 E psi 190 1800000 ft (includes partition Toad) lb-ft lb-ft 6.75 in. 22.5 in. in. in. in. 569.5 6407.2 OK Allowable Use Point Load = 0 Ibs Uniform Load = in3 in4 L/360 0.67 U240 = 945000 = 202500 478.13 in3 6.75 X Page 4 Reaction = lb-in lb-in in. 337.5 22.5 0 1575 Ibs /ft Ibs /ft Ibs /ft OK OK OK GLB 19125 Ibs Design Intelligence, LLC 3685 W Hwy 33 Rexburg,Llaho 83440 Type Fb psi Fv psi LVL GLB DF Beam 5 Type DF Span = Loads Live Load Dead Load Section Width = Section Depth = Deflection Live Load Total = Dead Load = Horizontal Shear 2600 2400 1300 Window Headers Fb psi Fv psi 1300 Tributary Area = 15 Snow 35 psf Live Load Moment = Dead Load Moment = 0 psf 15 psf Section Modulus Required 285 190 95 1641 703 0.01 i E psi E psi 1900000 ft lb-ft lb-ft in. 9.25 in. 1900000 1800000 1900000 Section Modulus Provided = 42.8 Moment of Ineritia Provided = 197.9 0.02 in. nr = 101 psi OK FV = 109.25 psi Allowable Use GRINGO'S 4/16/2003 STEVE ZOLLINGER Point Load = 0 Ibs Uniform Load = in3 in4 L/360 0.03 in L/240 21.63 in3 Page 5 19687.5 X 8438 Reaction = lb-in lb-in 9.25 525 Ibs /ft 0 Ibs /ft 225 Ibs /ft OK 0.17 in OK 0.25 in OK DF 1875 Ibs Spread Footing Design Values (1500 psf increased for depth) Allowable Soil Bearing Pressure = 2000', psf Min Reinforcing Factor = 0.002 Concrete Strength @ 28 days 2500', psi Steel Reinforcing (fy) = 40000 psi Roof and Floor Support - F3 Description Vertical Moment WB1 15000'. 25500 Ibs 0 ft -Ibs WB3 Ibs 0 ft -Ibs L = Length 5 ft B = Width 5 ft Weight 3750 Ibs Thickness 1 ft V = 44250 Ibs e = MN 0.0000 Qmax = V /BL(1 +6e /L) = 1770 psf Qmin = V /BL(1 -6e /L) = 1770 psf Reinforcing for Long Direction Use 5 ft. Wide X 12 in. Deep Footing Calculated Minimum Reinforcing = 1.44 in"in Rebar Size = #4 Area = 0.2 in'in Use 8 #4 7.71 in O.C. Reinforc for Short Direction Use 5 ft. Wide X 12 in. Deep Footing Calculated Minimum Reinforcin = 1.44 in"in Rebar Size = #4 Area = 0.2 in*in Use 8 #4 7.71 in. O.C. Design Intelligence, LLC 3685 W Hwy 33 Rexburg. Idaho 83440 GRINGO'S STEVE ZOLLINGER Page 1 4/16/2003 Spread Footing Design Values (1500 psf increased for depth) 2000 0.002 Allowable Soil Bearing Pressure = psf Min Reinforcing Factor = 2500 Concrete Strength @ 28 days psi Steel Reinforcing (fy) = 40000 psi Roof and Floor Support - F4 Description Vertical Moment WB2 22500 lbs 0 ft -Ibs WB4 38500 lbs 0 ft-lbs L = Length 6' ft B = Width 6 ft Weight 5400 Ibs Thickness 1 ft V = 66400 lbs e = MN 0.0000 Qmax = V /BL(1 +6e /L) = 1844 psf Qmin = V /BL(1 -6e /L) = 1844 psf Reinforcing for Long Direction Use 6 ft. Wide X 12 in. Deep Footing Calculated Minimum Reinforcing = 1.728 in *in Rebar Size = #4 Area = 0.2 in *in Use 9 #4 8.25 in O.C. Reinforcing for Short Direction Use 6 ft. Wide X 12 in. Deep Footing Calculated Minimum Reinforcing = 1.728 in *in Rebar Size = #4 Area = 0.2 in *in Use 9 #4 8.25 in. O.C. Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 GRINGO'S STEVE ZOLLINGER Page 2 4/16/2003 Foundation Design Allowable Bearing Capacity 1500 psf Max Roof Span = 30 ft 35 Max Floor Span = 30 ft Snow Load psf Wall Height = 9 ft Floor Live Load 40 psf Stem Wall Height = 9 ft Wall Dead Load 15 psf Stem Wall Width = 8 in Roof Dead Load 15 psf Brick Dead Load 0 15 psf Floor Dead Load psf Exterior Bearing Walls - F1 Proposed Footing Roof Loads 750 Ibs /ft Width 24 in Floor Loads 825 Ibs /ft Depth : 10 in Wall Load 135 lbs/ft Stem Wall Load 900 Ibs /ft Footing Load 250 Ibs /ft Total 2860 Ibs /ft Bearing Pressure = 1430 psf OK Reinforcing Requirements Min Reinforcing Factors Footing 0.002 Stem Wall Vertical 0.0012 #4 - - 0 :2' Horizontal 0.002 Reinforcing Bar in *in Footing Continuous Reinforcing Count 2 bars Stem WaII Continuous Reinforcing Count 9 bars Vertical - Reinforcing Spacing 18 in. Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 GRINGO'S STEVE ZOLLINGER Page 1 4/16/2003 Foundation Design Allowable Bearing Capacity 1500 psf Max Roof Span = 0 0 ft 35 Max Floor Span = ft Snow Load psf Wall Height = 9 ft Floor Live Load 40 psf Stem Wall Height = 9 ft Wall Dead Load 15 psf Stem Wall Width = 8 in. Roof Dead Load 15 psf Brick Dead Load 0 psf Floor Dead Load 15 psf Exterior Basement Stair Well - F2 Proposed Footing 16 Roof Loads 0 Ibs /ft Width in Floor Loads 0 Ibs /ft Depth 10 in Wall Load 135 Ibs /ft Stem Wall Load 900 Ibs /ft Footing Load 167 Ibs /ft Total 1202 Ibs /ft Bearing Pressure = 901 psf OK Reinforcing Requirements Min Reinforcing Factors Footing 0.002 Stem Wall Vertical 0.0012 #4 0.2 Horizontal 0.002 Reinforcing Bar in"in Footing Continuous Reinforcing Count 2 bars Stem Wall Continuous Reinforcing Count 9 bars Vertical - Reinforcing Spacing 18 in. Design Intelligence, LLC 3685 W Hwy 33 Rexburg, Idaho 83440 GRINGO'S STEVE ZOLLINGER Page 2 4/16/2003 Design Intelligence, LLC GRINGO'S 4/16/2003 3685 W Hwy 33 STEVE ZOLLINGER Rexburg, Idaho 83440 Shear Wall Analysis - Short Wall Wind Load = Roof Height = Wall Height = Length of Long Wall = Area at Mid Height of Wall = Wind Force = Shear Wall Length Shear /ft in Wall @ Mid Height Seismic Analysis Roof Dead Load Long Wall Length 80 ft Short Wall Length 60 ft Wall Dead Load Seismic Force @ Mid Height of Wall Shear Wall Length Shear per ft in Wall @ Mid Height 80 ft Width 15840 22 psf 720 198 163 4',' ft 10 ft 80 ft 80 ft ft^2 Ibs Ibs /ft Provide 1/2" APA rated sheathig with 8d na Is @ 6" o.c. at panel edges and 12" o.d. in the field. Blocking is required. Length 60 8 Height Length Ibs /ft Page 1 Seismic Multiplier = Load 24! (includes snow) Load 14 280 1 OK Provide 1/2" APA rated sheathig with 8d nails @ 6" o.c. at panel edges and 12" o.d. in the field. Blockin . is re . uired. 0.09 Weight 115200 Weight 29400 13014 Ibs Ibs Ibs