HomeMy WebLinkAboutAPP & DOCS - 03-00017 - District 7 Health Department - Additione, H�
PUIL PERMIT APPLICA REXBURG, ID DATE
THE UNDERSIGNED HEREBY APPLIES FOR A PERMIT FOR THE WORK HEREIN INDICATED
OR AS SHOWN AND APPROVED IN THE ACCOMPANYING PLANS AND SPECIFICATIONS.
OWNER A4 t s' P 47x — g JOB ADDRESS 21+,41 "" e d a PHONE * ;
BUILDER A �r . ARCHITECT _ _ _ �►3r ? / DESIGNER
STRUCTURE: ❑NEW O REMODEL w w
O ADDITION O REPAIR O RENEWAL O FIRE DAMAGE
O RESIDENCE MM. Q EDUCATIONAL Q GOVT Q RELIGIOUS ❑FENCE Q PATIO Q CARPORT Q GARAGE ❑AWNING
FOOTINGS FOUNDATION BASEMENT FLOORS EXT. WALLS INT. WALLS CEILING ROOF HEAT INSULAT
CONCRETE CONCRETE Q PARTIAL WOOD W000 &WOOD Q BUILT UP. 0jbAS
O MASONRY O MASONRY O FULL Q CONCRETE O MASONRY O MASONRY QWDRYWALL Q WOOD SH. COIL WCEILING
O OTHER Q OTHER "0 Q OTHER Q CONCRETE Q CONCRETE U PLASTER CauIP. SK O COAL FLOORS
"VENEER §DRYWALL (j Q FIREPLACE ' ERIMETER
'I 1 METAL U PLASTER O ACOUSTIC ROLL ROOF. Q ELECTRIC
O STUCCO O TILE 0 Q T OPEN Q METAL
This permit is issued subject to the regulations contained in the Uniform Building Code and Zoning Regulations of Rexburg, and it is hereby agreed
that the work to be done as shown in the plans and specifications will be completed in accordance with the regulations
pertaining and applicable thereto: The issuance of the permit does not waive restrictive covenants.
REMARKS;
DEPARTMENT OF BUILDING & ZONING
VALUE
FEE PAID Q CASH K APPU
BUILDING DATE ADDRESS
INSPECTOR
WHrrE- O—ft Copy CANARY- Suitdmg DePmMla 'S Copy PINK - Assessors COPY GOLDENROD - Inspector
/ APPLICATION FOR BUILDING PERMIT
CITY OF REXB URG, IIIAHO
Date of Application �i Ts Permit No. �
OWNER
Name i 9 0 Al ��i c/ & , l ,
Site Address._ o i e s7 k i, T s
Mailing Address / -
City /State /ZiP p�C�i Vre' c�
Telephone/Fax/Mobile
CONTRACTOR
Name —.-. 7� n �-� 0 4, o T .Z& G►
Mailing Address / 1 ^/ (� 5
City /State /ZiP ,�� 7t ew4 17al
Telephone/Fax/Mobile aCX �� 4 - 3S' // f oh,�r 7PI ;2 e R ,Z
PROJECT INFORMATION DEPARTMENT APPROVAL
Property Zone: Is existing use compatible with zoning, (screening parking, etc)
When was this building last occupied
Architect/ Engineer Firm Plan Name
Subdivision Lot Block
Circle One Residenti Commercial Educational Government Remodel Other
Circle One New House dditio emodel to House New Commercial Commercial Remodel
Circle One Basement: None/ Finished / Unfinished Other: None/ Patio/ Carport/ Awning N/A
Lot Square Footage Lot Width
Square Fee Garage Square Feet Number of Stories - H eight of Building
What will structure be used for: Home Home Business Apartment Commercial Other
Will there be an apartment? if so, how many units
Total Estimated Cost i Are you in a flood plain
Signature of Applicant
: k*+ k****************#*: k*****: k �� k********* *******: k�k** �k*****: k**** *:k�k * * * * * *�k * * *T:k * * * * * * * * * : *: :k *� *: •i::� *:�
Code Building Permit Fees
Zone , �d Plan Check Fees
Buildin T CITY ,OF REXBURG
Plumbing Permit Fees 7_1 [ S . �~`�
APR 1 7 2003 Digging Permit Fees
Water & Sewer Fees
PAID CASH $ — Front Footage Fee
CHECK$
TOTAL S
Signature of Inspector
Issued by (12( � V Lf6a
CITY OF REXBU iG
APPLICATION FOR PLUMBING PERMIT
OWNER FEES
Name E < # . t c �F t r 4:.. .l i i i Plumbing Permit ..................... $
Address '1 °/ f f ` 4 n w Tel. Sewer Inspection ................... $
Lot BIL Add. Inspection of Pipe ................... $
PW BER Inspection of Fixtures .. ...... .. $
Name 11 "
Address '; L/ Tel.
NATURE OF INSTALLATION TOTAL
Use
Rough Plumbing Septic Tank
Fixtures Water Piping
Complete Sewer
DESCRIPTION OF WORK
Bath Tubs Urinal
Showers Sink Trap IN OF
Laundry Trays Water Heater
Wash mi n °fir APR 1 7 2003
Toilet
Slop Sinks
Kitchen Sinks
F Drain
D rinking Fountains
Writer Softeners
Dish Washing Mach.
C lothes Washer
Lawn Sprinklers
g
R Plumbing
.Sewer
Other ay
Finish Plumbing
E
INSP. NAME
Received: Date
By
INSPECTOR'S RECORD
N
W
S
SUBCONTRACTOR LIST
Excavation &
Earthwork: C,
Concrete: Ticmnsn, ( v s
Masonry: T I&
Roofing: es e v ('nos 77
Insulation: l �
Drywall
Painting: �.g rPS' P L,9 FF�'C'o���L P, i.vTiN y
Floor Coverings: ��� i ,,' o r s
Plumbing: l,�iYi'���� l��uN►� �'nr�']
Heating:
Electrical: 5 �,¢�� S`,5 , '77,c Tr "e-
SPECIAL CONSTRUCTION
(Manufacturer or Supplier)
Roof Trusses: L3 M e
Floor / Ceiling Joists: Sf,,s
Cabinets: A rte,,, tG`� A t1 �"�►�, :�,� 7 s
Siding /Exterior Trim: } �„�,,, a „i
Other:
FROM : HOLLEY' UNITED PLUMBING PHONE NO. : 208 356 5055
UNITED
PLUMBRB G & HEATING
PHONE (208)356 -4111 * FAX (208)356 -5055
FAX
To: —,PpC.� A �}L4MP5Ga1
From: S7re-j E-
h�o
Date: 4A l 0 3
f
Apr. 02 2003 04:26PM P1
Fax: (, 14 - 09 3 Go
Wages: ( Including cover): I_
Re: EAS - I 01fA yI lk
Comments: &, 4 T gA c - t (aar-Aw paw ti t
1.1r - 3� *qS—V
PLV t3l �►� ` 9 C 0
If yo u N;,o Aja y T41 0G
S v
P.O. Box 97 Rexburg, Idaho 83440
a I d e rso n
karst & m it ro ❑ ❑
PO. Box 51911
Idaho Falls, Idaho 83405
Phone 208.522.4030
ARCHITECTS, P. . ❑
319 'A' Street
Idaho Falls, Idaho 83402
Fax 208.522.3020
March 25, 2003
Val Christensen
City of Rexburg
12 North Center
P.O. Box 280
Rexburg, ID 83440
RE: District Seven Health Offices - Addition & Renovation
Plan Review comments
Dear Mr. Christensen,
I have had an opportunity to address your comments and concerns on the above
referenced project. The following are responses to those comments. Be assured
that the General Contractor will receive a copy of these comments and will be
required to implement them into the project where applicable.
BUILDING OFFICIAL
Item #1: (Corrections to Loads /Calculations)
I have attached calculations from G & S Structural Engineering. The
calculations indicate that the building was sufficiently designed in the initial
phases to accommodate the new loading parameters.
Item #2: (Truss Clips)
The Contractor shall install at each roof truss and /or joist (1) Simpson H -1
seismic tie truss clips.
Item #3: (Corridor Fire Rating)
The following corridors shall be constructed of 1 -hr Fire Resistive Construction
(Hall 101, Hall 104, Hall 110, WIC Office 102) as indicated on the attached
UL rating parameters, GA No. RC2601, GA No.- WP3520 or GA No.- WP3605.
This construction shall include, but not be limited to, partition wall
construction, roof ceiling construction, doors and windows.
Where existing corridor wall construction receives infill construction or new
doors and frames, the new construction shall also meet the parameters
indicated above.
1 of 2 Alderson, Karst & Mitro P.A. 03/26/03
Item #4: (Exit Lighting)
I have attached a sketch indicating both new and existing exit lights.
Item #5: (Light Switching)
My Electrical Engineer has included Dual Level Switching in Addendum #1
Item #6: (Fire Dept Review)
See Below.
FIRE MARSHALL
Item #5: (Fire Extinguisher)
The existing portion of the building currently has (2) extinguishers, one located
in the mechanical Room 118, and one in Alcove 121. The Owner will provide
outside of this contract (2) new extinguishers, one in Waiting 101 and one in
Storage 108. Due to phasing of this project we will have the (2) new
extinguishers installed prior to the Owner occupying the addition portion.
Item #10: (Comments)
A. We will forward to your office (1) copy of the new Fire Alarm components
(Drawings & Specs) for your review and comments when the contractor
submits them to my Engineer for approval.
B. We have added to the contract by Addenda #1, the following items:
1) The pull station at Main Entrance is existing and will remain.
2) Add (1) strobe in Hallway 136.
3) Add (1) strobe in Hallway 117.
If you need any furth r help or clarifications, please call.
I
G
Craig G. K rst
Alderson, Karst & Mitro Architects, P.A.
CC: file
2 of 2 Alderson, Karst & Mitro P.A. 03/26/03
af� 011exiar7
STATE OF IDAHO
www.ci.rexb
P.O. Box 280
12 North Center Street
Rexburg, Idaho 83440
Phone (208) 359 -3020
Fax (208) 359 -3022
e -mail rexburg @ci.rexburg.id.us
3/14/2003
Craig Karst
AK &M Architects
P.O. Box 51977
Idaho Falls, ID 83405
Dear Craig,
I have reviewed the drawings for the District Seven Health Office Addition and have
identified the following discrepancies:
- 1. Page A6 of the drawings identify the design criteria as roof with a 33 lb /sq.ft. live load,
wind at 70 mph and seismic category 2B. Our snow load for roof design is 35 lb/sq.ft.
and the wind speed is 90 mph. A 2B seismic category is from the 1997 UBC and
Rexburg was in a seismic category 3. The 2000 IBC uses a different design for
seismic. Please provide new structural design using the correct criteria. Include the
calculations that support the new design. Include shear wall locations (including any
interior required by the code) and their nailing patterns.
2. Show truss clips where trusses connect to bearing walls.
Y 3. Please identify the corridor as being built to 1 hr. fire rated construction. Provide
details.
pj�M 4. Identify exit lights in corridor.
s _ 5. The Energy Conservation Code requires bi -level lighting in any room with more than
one light fixture. Please provide switching details for this purpose.
6. The Fire Department has reviewed the plans and I have attached a copy of their report
to the back of this document.
If you have any questions please give me a call at 359 -3020 ext. 324.
Sincerely,
Val Christensen
Building Official
cc: John Millar
Chris Huskinson
REXBURG MADISON COUNTY FIRE DEPARTMENT
P.O. Box 280
26 North Center
Rexburg, Idaho 83440
(2 08) 359 -3010
2000 INTERNATIONAL FIRE CODE Plan Date: 1 -27 -03
Plan Review Review Date: 2 -28 -03
Building Name: DISTRICT SEVEN HEALTH REMODEL
Building Address: BARNEY DAIRY ROAD AND NORTH SECOND EAST
Stories: ONE Type of Construction: II -B
Occupancy Classification: B Existing Floor Area:
APPROXIMATELY 3224 SQUARE FEET
New Construction Floor Area: APPROXIMATELY 2028 SQUARE FEET
1).Required Fire Flow (Appendix III -A): 1750 GPM /TWO HOURS
Comments: NONE
2).Water Supply (Article 9, Section 903) Required: YES
Fire Hydrant Location: NORTH THIRD EAST X3
Fire Hydrant Flows: OKAY
Fire Flow Test Location: SAME AS ABOVE
Fire Flow Supplied By: FD
Other Approved Water Source: NONE
Water Supply Acceptable: YES
Fire Hydrant Location Acceptable: YES
Water Supply Comments: NONE
3.)Fire Apparatus Access Roads (Article 9 Section 902)
Required: YES
Acceptable: Width: X Length: X Surface: X
Complete Road Acceptable: YES
Comments: NONE
4).Access Roads and Water Supply, Including Fire Hydrants Are
Required To Be Installed And Made Serviceable Prior To And During
Time Of Construction (Article 9 Section 901.3): YES
Comments: IF NOT INSTALLED AND MADE OPERATIONAL PRIOR TO
CONSTRUCTION A STOP WORK ORDER WILL BE ISSUED.
� Installation Of Portable Fire Extinguisher (Article 10 Section
``✓✓ 1002) Required: YES Location Acceptable: NOT SHOWN
Type Provided Acceptable: NOT SHOWN
Comments: MINIMUM SIZE OF 2A10BC REQUIRED WITHIN TRAVEL DISTANCES
THROUGHOUT FACILITY
6).Automatic Fire Extinguishing Systems: (Article 10 Section 1003
Required: NO Type Of System Being Installed:
Sprinkler System Monitoring Required (Article 10 Section 1003.3)
Required: NO Comments:
7).Standpipes (Article 10 Section 1004) Required: NO
Type Required:
Comments:
8) Ventilating Hood And Duct Fire Extinguishing System (Article 10
Section 1006.2) Required: NO
Type Being Provided:
Automatic Fuel Shutoff Shown (Article 10 Section 1006.2.4):
Portable Fire Extinguisher Shown (Article 10 section 1006.2.7):
Comments:
9).Fire Alarm Systems (Article 10 Section 1007)Required: NO, BUT
PLANS SHOW INSTALLATION OF NEW AND UPGRADE OF OLD SYSTEM
Type Of System Required: Manual: Automatic: Both: X
Type Of System Being Provided: Manual: Automatic: Both: X
Components Of System Shown: Smoke Detectors: X Heat Detectors: X
Manual Pull Station: X Sounding Devices: X Visual Devices: X
Door Holders: Duct Detectors: Flow Alarm:
Sprinkler Valve Monitoring: Fire Alarm System Acceptable: SEE
COMMENTS.
10).Other Corrections That Are Required By Special Occupancy Or
Conditions: SEE COMMENTS
Comments: PLEASE PROVIDE THE FOLLOWING IN REGARDS TO THE ALARM
SYSTEM: ALARM CONTROL AND SIGNALLING EQUIPMENT, ANNUNCIATION, POWER
CONNECTION, BATTERY CALCULATIONS, CONDUCTOR TYPE AND SIZES, VOLTAGE
DROP CALCULATIONS, MANUFACTURERS, MODEL NUMBERS AND LISTING
INFORMATION FOR EQUIPMENT, DEVICES AND MATERIALS, AND THE INTERFACE
FOR SAFETY CONTROL FUNCTIONS. SEE BELOW FOR MISSING HORN /STROBES,
PULL STATIONS, ETC. THAT NEED TO BE ADDED TO SYSTEM. ARE MAGNETIC
DOOR HOLDERS GOING TO BE USED THROUGHOUT THE BUILDING? IF S0,
PLEASE ADDRESS.
Plans As Submitted Are Acceptable: NO, PLEASE ADDRESS NOTED ITEMS
Plans Checked By: CHRIS HUSKINSON Date: 2 -28 -03
Please furnish comments back to the plan reviewer in the following
manner: Written Comments: X New Plans: X
ALARM SYSTEM ITEMS:
1. ADD PULL STATION AT MAIN ENTRANCE
2. ADD HORN /STOBE UNIT IN HALLWAY 136, WEST END
3. ADD HORN STROBE UNIT IN HALLWAY 117, NORTH END.
10702
A2 s
MW
K RT A.
!Ir N Nme
v
0
=o
=�v
y �
qC
4
I
I
- - -; 00
I
i
m7b i
I
I
I
i
I
I
I
I
I
L---- - - - - --
I
ll
I
I
�
,
I
---------
--
M*M
Arlo
I
P.4a I
I
1
I
I
PEM
I
I I
1
�If
CQ!OfIkH
O \ � I
i
F. YA%4 r
I
—
r-
I JCc IP_
1
1 I I
QfiCE /
_ / /
.fit
Li
III
i
j I I
I
I!
w
` \
!!I $ AT 80
-
1
gC4U�T
--
e
Tn
c�a - - - �
I
L -
I
�
- - - - - - - -
- - - - -
- - - - - - - - - -
- - -
-
I
I
I
- - - - -
- - - -
- - - - - - - - -.. - - - - - - - - - - - --i
I
I
I
I
MAIN LEVEL
RENOVATION PLAN �a
10702
A2 s
MW
K RT A.
!Ir N Nme
v
0
=o
=�v
y �
qC
4
G & S Structural Engineers
1600 John Adams Parkway
Suite 200
Idaho Falls, ID 83401
Telephone: (208) 523 -6918
E -mail: gs @dataway.net
Fax: (208) 523 -6922
March 21, 2003
#03101
Mr. Craig Karst
Alderson, Karst, and Mitro Architects
379 A Street
Idaho Falls, ID 83402
Re: rt mm ; n
Madison County, Idaho
Dear Mr. Karst,
G & S Structural Engineers performed the structural evaluation of the above referenced
addition. The drawings as shown meet or exceed the requirements of the 2000 International Building
Code. The evaluation incorporated a 35 psf roof snow load, wind forces due to a 90 mph 3 second
gust in exposure C, and seismic forces resulting from a seismic design category D.
This letter applies only for the above referenced addition and does not cover any other
structural, mechanical, electrical, or architectural features. Please don't hesitate to call if you have
any questions or if I can be of further assistance.
Sincerely,
a le�wlc_�
Adam Hoopes
DISTRICT SEVEN HEALTH OFFICE
ADDITION & RENOVATION
MADISON COUNTY, IDAHO
DESIGN CALCULATIONS FOR
DISTRICT SEVEN HEALTH OFFICE
ADDITION & RENOVATION
JOB # 03101
Client: ALDERSON, KARST, & MITRO ARCHITECTS
IDAHO FALLS, IDAHO
Designed by: Adam Hoopes
TABLE OF CONTENTS
PAGE
1.0 -1.5
2.0 -2.1
3.0
4.0
5.0 -5.4
END
DESCRIPTION
Lateral Analysis
Shear Walls
Holdowns
Footings
Beam and Joist Designs
G & S Structural Engineers
1600 John Adams Parkway
Suite 200
Idaho Falls, ID 83401
Telephone: (208) 523 -6918 E -mail: gs @dataway.net Fax: (208) 523 -6922
Project. �s /� �`�-� O �'` Project No.
Designed By c
z ToZt4l - e- �,4c yS�S
9O 112z.�� .,e �cvsv . C,
r J ® '�
lrdl .�s gr sx.
Z
14
L-A 4c S►�p. = z Y = 8
G &S Structural Engineers
Z /
Sheet
Project Project No. Date 3 13
Designed By
mtl_lr
F- t1cG �i ( '8-x 14 /2,g 2-�
F - 6Se/o -/--
(/, / z!) l el �? Z) _ 63 &s
g s r
[2/Z ?)I
,.► - = �� -,+«ll
k;t i5'�i ^q
7000
W
- - -- �-- 740
2
1 1
G &S Structural Engineers Sheet
W
N
N
NEw_
N
O
0
0
Z
m
m
Z
a
0
Z
a
r
W
C
r
v
Z
0
TABLE 1609.6.2.1(1)
MAIN WINDFORCE- RESISTING SYSTEM LOADS FOR A BUILDING WITH MEAN ROOF HEIGHT OF 30 FEET LOCATED IN EXPOSURE B (psf)
BASIC WIND
SPEED V
(mph-
3- second gust)
LOAD
DIRECTION
ROOF
ANGLE
HORIZONTAL LOADS
VERTICAL LOADS
MAXIMUM HORIZONTAL WALL LOADS
End zone
Interior zone
End zone
Interior zone
Windward overhang
Zone
Wall
Roof
Wall
Roof
Windward
roof
Leeward
roof
Windward
roof
Leeward
roof
End
zone
Interior
zone
1E
4E
1
4
0 to 5°
11.5
-5.9
7.6
-3.5
-13.8
-7.8
-9.6
-6.1
-19.3
-15.1
8.7
-6.7
6.4
-5.2
Transverse
20
15.9
-4.2
10.6
-2.3
-13.8
-9.6
-9.6
-7.3
-19.3
-15.1
10.8
-9.0
7.8
-6.7
85
30 ° <an gle <45°
12.9
8.8
10.2
7.0
5.0
-7.8
4.3
-6.7
-4.5
-5.2
9.6
-7.3
8.2
-6.1
Longitudinal
All angles
11.5
-5.9
7.6
-3.5
-13.8
-7.8
-9.6
-6.1
-19.3
-15.1
8.7
-6.7
6.4
>
0 to 5
12.8
-6.7
8.5
-4.0
1 -15.4
-8.8
-10.7
1 -6.8
-21.6
-16.9
9.8
-7.5
7.2
5.8
Transverse
20°
17.8
- 4.7
11.9
- 2.6
- 15.4
- 10.7
- 10.7
- 8.1
- 21.6
- 16.9
12.1
- 10.1
8.8
7 5
90
30 ° <an gle <45°
14.4
9.9
11.5
7.9
5.6
-8.8
4.8
-7.5
-5.1
-5.8
10.7
-8.1
9.1
-6.8
Longitudinal
All angles
12.8
-6.7
8.5
-4.0
-15.4
-8.8
-10.7
-6.8
-21.6
-16.9
9.8
-7.5
7.2
5 8
0 to 5°
15.9
-8.2
10.5
49
-19.1
-10.8
-13.3
-8.4
-26.7
-20.9
12.0
-9.3
8.8
-
Transverse
20°
22.0
-5.8
14.6
-3.2
-19.1
-13.3
-13.3
-10.1
-26.7
-20.9
14.9
-12.5
10.8
-9.3
100
30 ° <an>Ie545°
17.8
12.2
14.2
9.8
6.9
-10.8
5.9
-9.3
-63
-72
133
-10.1
11.3
-8.4
Longitudinal
All angles
15.9
-8.2
10.5
-4.9
-19.1
-10.8
-13.3
-8.4
-26.7
-20.9
12.0
9.;
8.8
- 7 - 2
0 to 5°
-5.4
4
-
-
- 0
1;
1
9
-7 9
Transverse
20o
24.2
4
11
5
4
4
4
-) 3. 0
1o.
+'
11.9
105
30 ° <an le545
19.7
-13.4
15.6
10.8
7.6
-11.9
6.6
-10.3
-6.9,
-7.9
1 14.6
-11.1
12.4
-9.2
Longitudinal
All angles
17.5
-9.1
11.6
-5.4
-21.0
-11.9
-14.6
-9.2
-29.4
-23.0
1 13.3
-10.3
9.7
-7.9
0 to 5
19.2
-10.0
12.7
-5.9
-23.1
-13.1
-16.0
-10.1
- 32.
- 25.3
14.6
- 11.3
10.7
- 8.7
Transverse
20°
26.6
-7.0
17.7
-3.9
-23.1
1 16.0
-16.0
1 -12.2
-32
-25.3
18.1
-15.1
13.1
-11.3
110
30 ° <an le <45°
21.6
14.8
17.2
11.8
8.3
-13.1
7.2
-11.3
-7.6
-8.7
16.0
1 -12.2
13.7
-10.1
Longitudinal
All angles
19.2
-10.0
12.7
-5.9
-23.1
-13.1
-16.0
-10.1
-32.3
-25.3
14.6
-11.3
10.7
- 8.7
0 to 5
22.8
-11.9
15.1
-7.0
-27.4
-15.6
-19.1
-12.1
-38.4
-30.1
17.3
-13.4
12.7
-10.3
Transverse
20°
31.6
-8.3
21.1
-4.6
-27.4
-19.1
-19.1
-14.5
-38.4
-30.1
21.5
-18.0
15.6
-13.4
120
30 ° <an le545°
25.7
17.6
20.4
14.0
9.9
-15.6
8.6
-13.4
-9.0
-10.3
19.1
-14.5
16.2
-12.1
Longitudinal
All angles
22.8
-11.9
15.1
-7.0
-27.4
-15.6
-19.1
-12.1
-38.4
-30.1
17.3
-13.4
1 12.7
-10.3
0 to 5°
24.8
-12.9
16.4
-7.6
-29.8
-16.9
-20.7
-13.1
-41.7
-32.6
18.8
-14.5
13.8
-11.2
Transverse
20°
34.3
-9.1
22.9
-5.0
-29.8
-20.7
-20.7
-15.7
-41.7
-32.6
23.3
-19.5
16.9
-14.5
125
30 ° <angle <_45
27.9
19.1
22.2
15.2
10.7
-16.9
9.3
-14.5
-9.8
-11.2
20.7
-15.7
17.6
-13.1
Lon "tudinal
All angles
24.8
12.9
16.4
7.6
29.8
16.9
20.7
13.1
41.7
32.6
18.8
14.5
13.8
11.2
(continued)
D
W
r
m
rn
0
io
o�
N
r
C
n
C
n
r
t7
m
U)
C)
Z
Designer: Adam Hoopes
Date: 03/21/2003
Project: District Seven Health - Rexburg
SEISMIC DESIGN:
G & S Structural Engineers
1600 John Adams Parkway
Idaho Falls, Idaho 83401
Type of Occupancy (Table 1604.5 and 1607.1)
Building Category or Seismic Use Group (Table 1604.5 and 1616.2)
Seismic Importance Factor: (Table 1604.5)
Soil Site Class (1615.1.1)
Response Modification Coeff. R (Table 1617.6)
Building Location: (Latitude & Longitude, or zip Code)
Approximate Fundamental Period, T
h„ = Height (feet) above base to highest level of building.
C Building Period Coefficient (See 1617.4.2.1)
Calculate Approximate Fundamental Period, T C /4
Maximum Considered Earthquake Response Accelerations:
Short Periods, Ss (CD rom)
1 Second Period, S1: (CD rom)
Earthquake Response Accelerations Adjusted for Site Class Effects:
Site Coefficients:
F =
Fa:
(Table 1615.1.2(1) or CD rom)
Fv:
(Table 1615.1.2(2) or CD rom)
SM s: = FaS
(Eq. 16 -16 or CD rom)
SM1: = FvS1
(Eq. 16 -17 or CD rom)
Design Spectral Response Acceleration Parameters (1615.1.3)
SDS = 2 /3S =
(Eq. 16-18)
SDI = 2 13S =
(Eq. 16 -19)
Commercial
Building Category = I
l
Site Class = D
R= 6
h„ = 17
C = 0.02
T = 0 167
III
S = 0.606 g
S = 0.193 g
F =
1.310 g
F =
2.030 g
SMs=
`- 0794'g
SM1 =
0 392 g
S = A 0.52 9 g
S DI = �6 9
Nature
of
Occupancy
Seismic
Use
Group
Table 1616.3.(1)
Table 1616.3.(2)
Largest SDC from
Tables 1616.3.(1) &(2)
SDC" to
Use for
Design
S
SDC*
S
SDC'
Commercial
I
0.529
D **
0.261
D **
D **
* SDC is the "Seismic Design Category"
S1 = 0.193
** Seismic Use Groups I and II structures located on sites with mapped maximum considered earthquake
spectral response acceleration at 1- second periodm S1, equal to or greater thatn 0.75g, shall be assigned
to Seismic Design Category E, and Seismic Use Group III structures located on such sites shall be
assigned to Seismic Design Category F.
J
Designer: Adam Hoopes
Date: 03/21/2003
Project: District Seven Health - Rexburg
General Procedure Response Spectrum:
To =.2Sd1 /Sds=
Ts =Sd1 /Sds=
For periods s To: Ts >_ For periods >_ To
Sa= .6 *T +.4 Sa = S
G & S Structural Engineers
1600 John Adams Parkway
Idaho Falls, Idaho 83401
(1615.1.4)
For periods > Ts:
Sa = Sd1
To =
Ts =
cn
Z
O rte'
Q ~
LU
w
0.600
0.500
0.400
2f S M
0 4 t g3
U
U
I f
3
.f
# �k�
��j �H�E F�9` Lk
}
�
w
0.300
Z }e
4dA 4y. Srµ9
O
i
Y � s u
�-
0.200
0.100
. F E
E
LU
0.000E
�
I
0.0
0.1 0.5 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
PERIOD T
Seismic Response Coefficient, Cs: (1617.4.1.1)
Since Seismic Design Category is D ** and S1 is less than 0.6 thus Cs min = 0.044Sds(le)
Cs shall not be less than: C = 0.044Sds(le) = 0.023 }
Cs calculated Cs = Sds /(R /le) = 0.088 }
Cs need not exceed: Cs = Shc /((R /le) *T) = 0.2601
Cs used for design of Seismic base shear = X088}
Seismic Base Shear: V = Cs *W
See Section 1617 for the E to use in the load combinations of Section 1605.4.
Q = The effect of horizontal seismic forces = Seismic base shear (V) = Cs *W
(Eq. 16 -37)
(Eq. 16 -35)
(Eq. 16 -36)
(Eq. 16 -34)
Seismic load effect E. Where the effects of gravity and the seismic ground motion are additive,
seismic load, E, for use in Formulas 16 -5, 10, and 17 shall be defined by:
E = p *Q + 0.2 *Sp *D
(Eq. 16 -28)
Where the effects of gravity and seismic ground motion counteract, the seismic load, E,
for use in Formulas 16 -6, 12, and 18 shall be defined by:
t?:099 9
0 494 g
T =p Sa /g
0.0 0.212
0.1 0.529
0.5 0.529
0.6 0.435
0.8 0.326
1.0 0.261
1.2 0.218
1.4 0.187
1.6 0.163
1.8 0.145
2.0 0.131
E = p *Q - 0.2 *SpS *D (Eq. 16 -29)
i,s
MCE Parameters - Conterminous 48 States
Zip Code - 83440
Central Latitude = 43.763462
Central Latitude = 43.763462
Central Longitude = - 111.609017
Data are based on
the 0.10 deg grid set
Period SA
Period
(sec) ( %g)
0.2 060.6
Map Value, Soil Factor of 1.0
1.0 019.3
Map Value, Soil Factor of 1.0
MCE Parameters x Specified Soil Factors
0.2 080.0
Soil Factor of 1.32
1.0 039.2
Soil Factor of 2.03
MCE Parameters - Conterminous 48 States
Zip Code - 83440
Central Latitude = 43.763462
Central Longitude = - 111.609017
Data are based on the 0.10 deg grid set
Period
SA
(sec)
( %g)
0.2
060.6
Map Value, Soil Factor of 1.0
1.0
019.3
Map Value, Soil Factor of 1.0
MCE SPECTRUM x SOIL FACTORS
Fa = 1.32
Fv = 2.03
Period
SA
(sec)
( %g)
0.000
032.0
0.4FaSs
0.098
080.0
To
0.200
080.0
T =0.2, FaSs
0.490
080.0
Ts
0.500
078.5
0.600
065.4
0.700
056.1
0.800
049.1
0.900
043.6
1.000
039.2
T =1.0, FvS1
1.100
035.7
1.200
032.7
1.300
030.2
1.400
028.0
1.500
026.2
1.600
024.5
1.700
023.1
1.800
021.8
1.900
020.7
2.000
019.6
Project . Project No.
Designed By
�.0
Date
33
l/= �o
,-�
�Alox
V,
44 s
(!:�, �, 1 pi7Z
13 5' Fly
/Dw / % "c "' o^� 0 le-
In5?
G &S Structural Engineers
L
Sheet
N
O1
N
N
O
0
0
z
M
M
z
O
z
D
r
TABLE 2306.3.1— continued
RECOMMENDED SHEAR (POUNDS PER FOOT) FOR WOOD STRUCTURAL PANEL DIAPHRAGMS
WITH FRAMING OF DOUGLAS- FIR - LARCH, OR SOUTHERN PINEe FOR WIND OR SEISMIC LOADING
`V
h
o i
t i �v f
t"le�t t ,i
.i: 1 .t..l'Y.AI i, i�.. " .YTS;.✓ .:5� i.� -��1 F:. �.I`. ^Kd .� x it
D
r
M
N
W
O
Of
W
0
0
0
v
BLOCKED DIAPHRAGMS U
UNBLOCKED DIAPHRAGMS
Fastener spacing (inches) at
diaphragm boundaries (all cases) F
Fasteners spaced 6" max. at
at continuous panel edges parallel s
supported edgesb
to load (Cases 3, 4), and at
all panel edges (Cases 5 and 6)b
6 4
4 2
2 - 2
2c C
Case 1 (No
COMMON M
MINIMUM 6
NAIL SIZE M
MINIMUM M
MINIMUM N
NOMINAL u
unblocked
OR F
FASTENER N
NOMINAL W
WIDTH OF F
Fastener spacing (inches) at e
edges or A
All other
STAPLEf P
PENETRATION P
PANEL F
FRAMING o
other panel edges c
continuous c
configurations
LENGTH I
IN FRAMING T
THICKNESS M
MEMBER (
(Cases 1, 2, 3 and 4)b j
joints parallel (
(Cases 2, 3,
PANEL GRADE A
AND GAGE (
(inches) (
(inch) (
(inches) 6
to load) 4
4, 5 and 6)
6 6
6 4
4 3
3 t
11/2 3
3/8 2
2 1
160 2
210 3
315 3
360 1
140 1
105
16 Gage 1
1 3
3 1
180 2
235 3
355 4
400 1
160 1
120
2 2
255 3
340 5
505 5
575 2
230 1
170
8d 1
1 3
3 2
285 3
380 5
570 6
645 2
255 1
190
7 /16
1 2
2 1
165 2
225 3
335 3
380 1
150 1
110
16 Gage 1
1 3
3 1
190 2
250 3
375 4
425 1
165 1
125
Sheathing, 1
Single Floor and 2
2 2
270 3
360 5
530 6
600 2
240 1
180
other grades 8
8d 1
1 3
15/32
3 3
300 4
400 6
600 6
675 2
265 2
200
2 2
290 3
385 5
575 6
655 2
255 1
190
and PS 2 l
lOdd 1
1 3
3 3
325 4
430 6
650 7
735 2
290 2
215
(continued)
1 2
2 1
160 2
210 3
315 3
360 1
140 1
105
16 Gage 1
1 3
3 1
180 2
235 3
355 4
405 1
160 1
120
10dd 1
1 2
2 3
320 4
425 6
640 7
730 2
285 2
215
3 3
360 4
480 7
720 8
820 3
320 2
240
19 /32
1 2
2 1
175 2
235 3
350 4
400 1
155 1
115
16 Gage 1
1 3
3 2
200 2
265 3
395 4
450 1
175 1
130
(continued)
.i: 1 .t..l'Y.AI i, i�.. " .YTS;.✓ .:5� i.� -��1 F:. �.I`. ^Kd .� x it
D
r
M
N
W
O
Of
W
0
0
0
v
Y"
7
Project _ ( _ Project No.
Designed By_
w4L,05
Sa 5�
`Jc
�U
Date � 63
r-2/�
2/3 C
pL= 2 /3 9 * /s�
23Yc.)
9
(
M B3 �P= M5(9) - 80K33)< 3312)
a yc 67%1 a�2c ✓2� v 2x� S -e q NO GrJ �G 4
,�
G &S Structural Engineers Sheet
Project Project No
Designed By_
Lc. c�
2
p/X _ 2. "
x61
Date ` L/ O-3
/t t/.ac _ F,-AO &
0
f .VT� 2to,L
5 3'
/SDa
G &S Structural Engineers Sheet
Project -1 Project No
Designed By O
�i�17r.L� S
s'
�L
r��
Date 3 Z11 "
-�;- x % L VL
Aga y��
VL-
G &S Structural Engineers Sheet
COMPANY PROJECT
G&S Structural Engineers
WoodWorks' 1600 John Adams Pkwy. Suite 200
Idaho Falls, Idaho
SOF/WARE FOR WOOD DESIGN Adam Hoopes
- - - - - - - - - - -. - - Mar. 21 - 2003 1 3 2 9:28 -
Design Check Calculation Sheet
Sizer2002a
LOADS: ( Ibs, psf, or plf )
Load Type Distribution Magnitude Location [ft] P to tern
_ Start End Start End _ Lo ad?
Loadl Dead Full UDL 100.0 No
[Load Snow Full UDL 1 75.0 No
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) :
LN
0 '
16' -6"
Dead
r 940
940
Live
1444,
1444
Total
2384;
2384
Bearing:
-- -- --
Mr =
Length
-
1.0
1.0
LVL n -ply, 1.8E, 2600Fb, 1- 3/4x9 -1/4 ", 3 -Plys
Self Weight of 14.0 plf automatically included in loads;
Load combinations: [CC-IBC;
SECTION vs. DESIGN CODE NDS -1997: ( Ibs, Ibs -ft, or in)
F C riterion
Shear
Analysis
V @d =
V alue
2161
Desi n
Vr =
Value
10612
Analysis /Design
V /Vr = 0.20
Bending( +)
M =
9835
Mr =
19327
M /Mr = 0.51
Live Defl'n
0.47 =
L/422
0.55 =
L/360
0.85
Total Defl'n
0.77 =
L/256
1.10 =
L /180
0.70
ADDITIONAL DATA:
FACTORS: F CD CM Ct CL CF CV Cfu Cr LC#
Fb' += 2600 1.15 1.00 1.00 1.000 1.04 1.000 1.00 1.00 2
Fv' = 285 1.15 1.00 1.00 2
Fcp'= 750 1.00 1.00 -
E' = 1.8 million 1.00 1.00 2
Bending( +): LC# 2 = D +S, M = 9835 lbs -ft
Shear LC# 2 = D +S, V = 2384, V @d = 2161 lbs
Deflection: LC# 2 = D +S EI= 623.27e06 lb -in2 /ply
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D =dead L =live S =snow W =wind I= impact C= construction CLd= concentrated)
(All LC's are listed in the Analysis output)
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. SCL -BEAMS (Structural Composite Lumber): the attached SCL selection is for preliminary design only. For final member design
contact your local SCL manufacturer.
3. BUILT -UP SCL- BEAMS: contact manufacturer for connection details when loads are not applied equally to all plys.
COMPANY 1 PROJECT
G&S Structural Engineers
Wood Works' 1600 John Adams Pkwy. Suite 200
Idaho Falls, Idaho
SOF/WARE FOR WOOD DESIGN Adam Hoopes
Mar. 21, 2003 13:24:01 Beaml
Design Check Calculation Sheet
Sizer 2002a
LOADS: ( Ibs, psf, or plf )
Load Type Distribution Magnitude Location [ft] j Pattern
Start End Start End (Load?
Loadl:Dead Full UDL 920.0 No
Load2 Snow Full UDL _� 980.0 No
MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) :
V
5'
Dead
Live
T 1071
2450
-- - --
1071
2950
Total
3521
Shear
3521
Bearing:
r-
_
I V /Vr = 0.46
Length 1
1.0
4401
1.0
LVL n -ply, 1.8E, 2600Fb, 1- 3/4x5 -1/2 ", 3 -Plys
Load combinations: ICC -IBC; Self Weight of 8.32 plf automatically included in loads;
SECTION vs. DESIGN CODE NDS -1997: ( Ibs, Ibs -ft, or in)
_Criterion_
Analysis
Value
Design
Value
Analysis /Design
Shear
V @d =
2875
Vr =
6310
I V /Vr = 0.46
Bending( +)
M =
4401
Mr =
7335
M /Mr = 0.60
Live Defl'n
0.11 =
L /570
0.17 =
L/360
0.63
Total Defl'n
0.15 =
L/396
0.33 =
L /180
0.45
ADDITIONAL DATA:
FACTORS:
F CD
Fb' +=
2600 1.15
Fv' =
285 1.15
Fcp'=
750
E' =
1.8 million
CM Ct CL CF Cv Cfu Cr LC#
1.00 1.00 1.000 1.11 1.000 1.00 1.00 2•
1.00 1.00 2
1.00 1.00 _
1.00 1.00 2
Bending( +): LC# 2 = D +S, M = 4401 lbs -ft
Shear : LC# 2 = D +S, V = 3521, V @d = 2875 lbs
Deflection: LC# 2 = D +S EI= 131.02e06 lb -in2 /ply
Total Deflection = 1.00(Dead Load Deflection) + Live Load Deflection.
(D =dead L =live S =snow W =wind I= impact C= construction CLd= concentrated)
(All LC's are listed in the Analysis output)
S Z.
DESIGN NOTES:
1. Please verify that the default deflection limits are appropriate for your application.
2. SCL -BEAMS (Structural Composite Lumber): the attached SCL selection is for preliminary design only. For final member design
contact your local SCL manufacturer.
3. BUILT -UP SCL - BEAMS: contact manufacturer for connection details when loads are not applied equally to all plys.
tan .' � a s 3
v,. 16" TJI® /Pro TM -350 2 p lies ^ 16" o/c �G� �tSt�
TJ- Beam(TM) 6.05 Serial Number: 7002002043 r M
Page 03/21/20032:11:19PM THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS
Page 1 Engine Version: 1.5.12
FOR THE APPLICATION AND LOADS LISTED
Overall Dimension: 34'
17'
17'
Product Diagram is Conceptual.
LOADS:
Analysis is for a Joist Member.
Primary Load Group - Office Bldgs - Offices (psf): 100.0 Live at 100 % duration, 15.0 Dead, 20.0 Partition
SUPPORTS:
Input Bearing Vertical Reactions (Ibs)
Width Length Live /Dead /Uplift/Total
1 Stud wall 3.50" 2.25" 1007 / 304 / 0 11311
2 Stud wall 3.50" 3.50" 2799 / 980 / 0 / 3778
3 Stud wall 3.50" 2.25" 1007 / 304 / 0 / 1311
DESIGN CONTROLS:
Detail Other
End, Rim 1 Ply 1 1/4" 0.8E TJ- Strand Rim Board®
Intermediate None
End, Rim 1 Ply 1 1/4" 0.8E TJ- Strand Rim Board®
- Deflection Criteria: STAN DAR D(LL:0.400 ",TL:U240).
- Allowable moment was increased for repetitive member usage.
- Deflection analysis is based on composite action with single layer of 23/32 ", 3/4" Panels (24" Span Rating) GLUED & NAILED wood decking.
- Bracing(Lu): All compression edges (top and bottom) must be braced at 2' 8" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve
member stability.
- Concentrated load requirements for standard non - residential floors have been considered.
-The load conditions considered in this design analysis include alternate member pattern loading.
TJ -Pro RATING SYSTEM
-The TJ -Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 23/32 ", 3/4" Panels (24" Span Rating) decking. The controlling
span is supported by walls. Additional considerations for this rating include: Ceiling - None. A structural analysis of the deck has not been performed by the program. Comparison
Value: 3.29
ADDITIONAL NOTES:
- IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). TJ warrants the sizing of its products by this software will be accomplished in accordance
with TJ product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user.
This output has not been reviewed by a TJ Associate.
-Not all products are readily available. Check with your supplier or TJ technical representative for product availability.
-THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
- Allowable Stress Design methodology was used for Building Code UBC analyzing the TJ Custom product listed above.
-Note: See TJ SPECIFIER'S / BUILDER'S GUIDES for multiple ply connection.
PROJECT INFORMATION:
OP ERATOR INFORMATION:
Adam Hoopes
G &S Structural Engrs.
1600 John Adams Pkwy. Suite 200
Idaho Falls, Idaho 83401
Phone : 208 -523 -6918
Fax 208 -523 -6922
gs @dataway.net
Copyright Z 2002 by Trus Joist, a Weyerhaeuser Business
TJIS and TJ -Beam% are registered trademarks of Trus Joist.
e -I Joist and TJ-Pro- are trademarks of Trus Joist.
Maximum
Design
Control
Control
Location
Shear (Ibs)
1889
1628
3940
Passed (41%)
Lt. end Span 2 under Floor loading
Vertical Reaction (Ibs)
3778
3778
4640
Passed (81%)
Bearing 2 under Floor loading
Moment (Ft -Lbs)
-6344
-6344
14986
Passed (42 %)
Bearing 2 under Floor loading
Live Load Deft (in)
0.119
0.400
Passed (0999 +)
MID Span 1 under Floor ALTERNATE span loading
Total Load Defl (in)
0.144
0.840
Passed (0999 +)
MID Span 2 under Floor ALTERNATE span loading
TJPro
64
45
Passed
Span 1
- Deflection Criteria: STAN DAR D(LL:0.400 ",TL:U240).
- Allowable moment was increased for repetitive member usage.
- Deflection analysis is based on composite action with single layer of 23/32 ", 3/4" Panels (24" Span Rating) GLUED & NAILED wood decking.
- Bracing(Lu): All compression edges (top and bottom) must be braced at 2' 8" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve
member stability.
- Concentrated load requirements for standard non - residential floors have been considered.
-The load conditions considered in this design analysis include alternate member pattern loading.
TJ -Pro RATING SYSTEM
-The TJ -Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 23/32 ", 3/4" Panels (24" Span Rating) decking. The controlling
span is supported by walls. Additional considerations for this rating include: Ceiling - None. A structural analysis of the deck has not been performed by the program. Comparison
Value: 3.29
ADDITIONAL NOTES:
- IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). TJ warrants the sizing of its products by this software will be accomplished in accordance
with TJ product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user.
This output has not been reviewed by a TJ Associate.
-Not all products are readily available. Check with your supplier or TJ technical representative for product availability.
-THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
- Allowable Stress Design methodology was used for Building Code UBC analyzing the TJ Custom product listed above.
-Note: See TJ SPECIFIER'S / BUILDER'S GUIDES for multiple ply connection.
PROJECT INFORMATION:
OP ERATOR INFORMATION:
Adam Hoopes
G &S Structural Engrs.
1600 John Adams Pkwy. Suite 200
Idaho Falls, Idaho 83401
Phone : 208 -523 -6918
Fax 208 -523 -6922
gs @dataway.net
Copyright Z 2002 by Trus Joist, a Weyerhaeuser Business
TJIS and TJ -Beam% are registered trademarks of Trus Joist.
e -I Joist and TJ-Pro- are trademarks of Trus Joist.
TJ- 8eam(TM)6.OSSerial "Nu o,rBusi 16" TJI® /Pro(TM) -350, 2 plies a@ 16" o/c
User:2 03/21/20032:11:38PM THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS
Page 1 Engine Version: 1.5.12
FOR THE APPLICATION AND LOADS LISTED
1❑' ;F2]
17'
Product Diagram is Conceptual.
LOADS:
Analysis is for a Joist Member.
Primary Load Group - Office Bldgs - Offices (psf): 100.0 Live at 100 % duration, 15.0 Dead, 20.0 Partition
SUPPORTS:
Input
Bearing
Vertical Reactions (Ibs)
Detail
Other
Width
Length
Live /Dead /Uplift/Total
1 Stud wall 3.50"
2.25"
1133 / 397 / 0 / 1530
End, Rim
1 Ply 1 1/4" 0.8E TJ- Strand Rim Board®
2 Stud wall 3.50"
2.25"
1133 / 397 10 / 1530
End, Rim
1 Ply 1 1/4" 0.8E TJ- Strand Rim Board®
DESIGN CONTROLS:
Maximum
Design Control
Control
Location
Shear (Ibs)
1493
-1478 3940
Passed (38 %)
Rt. end Span 1 under Floor loading
Vertical Reaction (Ibs)
1493
1493 2616
Passed (57 %)
Bearing 2 under Floor loading
Moment (Ft -Lbs)
6188
6188 14986
Passed (41 %)
MID Span 1 under Floor loading
Live Load Defl (in)
0.159 0.400
Passed (U999 +)
MID Span 1 under Floor loading
Total Load Deft (in)
0.215 0.829
Passed (0927)
MID Span 1 under Floor loading
TJPro
64 45
Passed
Span 1
- Deflection Criteria: STAN DAR D(LL:0.400 ",TL:U240).
- Allowable moment was increased for repetitive member usage.
- Deflection analysis is based on composite action with single layer of 23/32 ", 3/4" Panels (24" Span Rating) GLUED & NAILED wood decking.
Bracing(Lu): All compression edges (top and bottom) must be braced at 2' 8" o/c unless detailed otherwise. Proper attachment and positioning of lateral bracing is required to achieve
member stability.
- Concentrated load requirements for standard non - residential floors have been considered.
TJ -Pro RATING SYSTEM
-The TJ -Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 23/32 ", 3/4" Panels (24" Span Rating) decking. The controlling
span is supported by walls. Additional considerations for this rating include: Ceiling - None. A structural analysis of the deck has not been performed by the program. Comparison
Value: 3.29
ADDITIONAL NOTES:
- IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). TJ warrants the sizing of its products by this software will be accomplished in accordance
with TJ product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user.
This output has not been reviewed by a TJ Associate.
-Not all products are readily available. Check with your supplier or TJ technical representative for product availability.
-THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.
- Allowable Stress Design methodology was used for Building Code UBC analyzing the TJ Custom product listed above.
-Note: See TJ SPECIFIER'S / BUILDER'S GUIDES for multiple ply connection.
PROJECT INFORMATION:
OPERA INFORMATION:
Adam Hoopes
G &S Structural Engrs.
1600 John Adams Pkwy. Suite 200
Idaho Falls, Idaho 83401
Phone: 208 -523 -6918
Fax :208 -523 -6922
gs @dataway.net
Copyright E. 2002 by Trus Joist, a Weyerhaeuser Business
TJIS and TJ -Beamg are registered trademarks of Trus Joist.
e -I Joist-,Pro- and TJ -Pro° are trademarks of Trus Joist.
ROOF- CE1UNG SYSTEMS
GA FILE NO. RC 4W WAMIC 1 HO
GYPSUM BOARD, WOOD JOISTS, ROOF COVERING FIRE
Base layer 5 /e" type X gypsum wallboard applied at right angles to 2 x 10 wood joists 24"
o.c. with 1 Type W or S drywall screws 24" o.c. Face layer 5 /s" type X gypsum
wallboard or gypsum veneer base applied at right angles to joists with 1 7 /8" Type S
drywall screws 12" o.c. at joints and intermediate joists and 1 1 /2 " Type G drywall screws
12" o.c. placed 2" back on either side of end joints. Joints offset 24" from base layer
joints. Wood joists supporting 1 /2 ' plywood with exterior glue applied at right angles to
joists with 8d nails. Appropriate roof covering. Ceiling provides one hour fire
resistance protection for wood framing, including trusses. Approx. Ceiling
Weight: 5 psf
Fire Test: FM FC 172,2-25-72
This Space Left Blank
GA- 600 -2000 t Contact the manufacturer for more detailed information on proprietary products. 115
WALLWANbINTERIOR PAWITIONS, "WOOD FRAMED
GA FILE NO. GENERIC'
1 HOUR 351b 39 ST
GYPSUM WALLBOARD, WOOD STUDS
FIRE SULINt?`
One layer 5 /e" type X plain or predecorated gypsum wallboard applied parallel to each side
...�„
of 2 x 4 wood studs 24" o.c. with 6d coated nails, 1 7 /8 11 long, 0.0915" shank, 1 /4" heads,
7" o.c. at joints and top and bottom plates and 3 /8" beads of adhesive at intermediate
studs.
Joints staggered 24" on opposite sides. (LOAD- BEARING)
Thickness: 4
Approx. Weight: 7 psf
Fire Test: FM WP 90, 8 -21 -67
Sound Test: G &H NG- 246FT, 7 -2-65
GA FILE NO. WP 36 f5 GENERIC '
i HOUR 30 to 34 8TC
FIRE SOUND
GYPSUM WALLBOARD, WOOD STUDS
One layer 5 /e" type X plain or predecorated gypsum wallboard, water- resistant gypsum
_
backing board, or gypsum veneer base applied parallel or at right angles to each side of
2 x 4 wood studs 16" o.c. with 6d coated nails, 1 /8" long, 0.0915" shank, Y4" heads, 7"
o.c. Joints of square edge, bevel edge or predecorated wallboard may be left exposed.
Joints staggered 16" on opposite sides. (LOAD - BEARING)
Thickness: 4
Approx. Weight: 7 psf
Fire Test: UL R1319-4,-6,6-17-52;
UL R2717-39,1-20-66;
UL R3501-52,3-15-66,
UL Design U305;
ULC Design W301
Sound Test: OR 648, 2-4-64
GA FILE NO. WP 3615 PROPRIETARY f
1 HOUR Sty t4 34 STC
GLASS MAT GYPSUM BOARD, WOOD STUDS
SOUND '
One layer 5 1e" proprietary type X glass mat water - resistant gypsum backing board applied
parallel or at right angles to 2 x 4 wood studs 16 o.c. with phosphate coated nails, 1
long, 1 /4" diameter cupped heads, 8" o.c.
Joints staggered 16" on opposite sides and covered with 10x10 mesh glass tape and tile
adhesive. (LOAD - BEARING)
PROPRIETARY GYPSUM BOARD
Thickness: 4
G -P Gypsum 5 J e " Dens - Shield Fireguard®
Approx. Weight: 7 psf
Fire Test: WHI- 495 -0853, 5- 14-87;
WHI - 495 -0854, 5 -15 -87
Sound Test: See WP 3605
(OR 64 -8, 2 -4 -64)
GA FRA NQ. WP GENERIC '
I HOUR 30 to 34 STC
GYPSUM VENEER BASE, GYPSUM VENEER PLASTER,
F IRE ". ND
WOOD STUDS
One layer 1 /2" type X gypsum veneer base applied at right angles to each side of 2 x 4 wood
studs 16" o.c. with 5d etched nails, 1 long, 0.099" shank, 1 /4" heads, 8" o.c. IN"
gypsum veneer plaster applied over each face.
Vertical joints staggered 16" and horizontal joints 12" on opposite sides. Sound tested
.�
without gypsum veneer plaster. (LOAD - BEARING)
Thickness: 4
Approx. Weight: 7 psf
Fire Test: UC, 1 -12-66
Sound Test: G &H I13I -35FT, 5 -26-64
GA- 600 -2000 t Contact the manufacturer for more detailed information on proprietary products. 59