HomeMy WebLinkAboutAPP & DOCS - 04-00359 - BYUI Mail Room - RemodelCITY OF REXB URG
BUILDING PERMIT APPLICATION
19 E MAIN, REXBURG, ID. 83440
208 - 359 -3020 X326
0400359
BYUI Mail Room Remodel
PARCEL NUMBER:
SUBDIVISION:
UNIT#
BLOCK# LOT#
OWNER: CONTACT PHONE # - J96 - ;�!JI9
PROPERTY ADDRESS:
PHONE #: Home ( ) Work (?Ob) 4 %( - — Cell (us) ;7,o ®G6�
dYv' /J.9r/
OWNER MAILING ADDRESS: 1'l;:r4C#�1 CITY: , x8i1RLG STATE: //J ZIP: 9,316 --4-'2or
APPLICANT (If other than owner)
(If applicant if other than owner, a statement authorizing applicant to act as agent for owner must accompany this application.)
MAILING ADDRESS OF APPLICANT
CITY: STATE; ZIP
PHONE #: Home ( ) Work ( ) Cell ( )
CONTRACTOR: -9dA P1 ,11v PHONE Home# Work# S
MAILING ADDRESS:
How many houses are located on this property? /yo&?'
Did you recently purchase this property? (9 Yes (If yes give owner's name)
Is this a lot split ? YES (Please bring copy of new legal description of property)
PROPOSED USE: /MAY le/� 6y V C
(i.e., Single Family Residence, Multi Family, Apartments, Remodel, Garage, rommerci dditi&n) Etc.)
APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury, I hereby
certify that I have read this application and state that the information herein is correct and I swear that any information which may
hereafter be given by me in hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be
truthful and correct. I agree to comply with all City regulations and State laws relating to the subject matter of this application and
hereby authorized representatives of the City to enter upon the above - mentioned property for inspections purposes. NOTE: The
building official may revoke a permit on approval issued under the provisions of the 2000 International Code in cases of any false
statement or misrepresentation of fact in the application or on the plans on which the permit or approval was based. Permit void if not
started within 180 days. Permit void if work stops for 180 days.
C.
of Owner /Applicant
DATE
WARNING — BUILDING PERMIT MUST BE POSTED ON CONSTRUCTION SITE!
Plan fees are non - refundable and are paid in full at the time of application beginning January], 2005.
City of Rexburg's Acceptance of the plan review fee does not constitute plan approval
* *Building Permit Fees are due at time of application **
* *Building Permits are void if you check does not clear **
NAME Y6
PROPERTY ADDRESS (, �`' S. y CI' Permit#
SUBDIVISION
Dwelling Units: Parcel Acres:
Front Footage (if applicable) ---
SURFACE SQUARE FOOTAGE: (Shall include the exterior wall measurements of the building)
First Floor Area A/c A4 Tioa/i&
Second floor /loft area ZS® ,S'. F.
Third floor /loft area —
Shed or Barn
Remodel (Need Estimate) $
Unfinished Basement area
Finished basement area
Garage area
Carport/Deck (30" above grade)Area
PLUMBING
PLUMBERS NAME W1111 ADDRESS
CITY STATE ZIP PHONE (
FIXTURE COUNT
CLOTHES WASHING MACHINE 0
DISHWASHER
FLOOR DRAIN
GARBAGE DISPOSAL
C
HOT TUB /SPA
P
SINKS
(Lavatories, kitchens, bar, mop)
WATER METER COUNT
SPRINKLERS 0
TUB /SHOWERS
TOILET/URINAL
WATER HEATER
WATER SOFTENER
WATER METER SIZE
HEAT (Circle all that apply) Gas Oil Lal Fireplace Electric
Commercial Buildings & Apartments with 3 or more units Only
BUILDING ESTIMATE $ M era
PLUMBING ESTIMATE $ T
STORM WATER LENGTH
FRONT FOOTAGE
STRUCTURES
DESCRIPTION
USE
BEDROOMS
UNITS
NON CENSUS
OCCUPANCY IOAD
EXITS
SETBACKS
FRONT SIDE SIDE
CONSTRUCTION
ROOF
SANITATIONMETHOD
HEAT
FLOOD ZONE
FENCE TYPE
OCCUPANCY
BACK
0)
BYU -Idaho
Design and Construction
450 S. Physical Plant Way
Rexburg, Idaho 83460 -8205
496 -1138 496 -5138
Plan analysis based on
the 2000 International Building Code
Project Number: 2004 -1 Date: October 13, 2004
Project Name: ASB Mail Room
Address: 525 S Center
Contractor: sHOPS
Occupancy: B,S -2 Architect: Rulon
Construction: V -B Engineer:
Report By: Rulon Nielsen, Archi
NOTE: The code items listed in this report are not intended to be a
complete listing of all possible code requirements in the 2000 IBC.
It is a guide to selected sections of the code.
Report created using Plan Analyst software by b w & a. (719) 599 -5622
SPRINKLER SYSTEM:
NFPA 13 sprinkler system throughout the building
Sprinkler system used for 1 hr. substitution Table 601, Note
FRONTAGE INCREASE:
Perimeter of the entire building = 725 feet.
Perimeter which fronts a public way or accessible open space = 725 feet.
Minimum width of public way or accessible open space = 100
FL NAME
OCC
MAX FLR
AREA
ALLOWED RATIO
STATUS
-------------------------------------------------------------------
2 Office
B
ok
1200
UNLIMITED
AREA
OK
TOTAL FOR FLOOR
1200
UNLIMITED
AREA
OK
1 Office
B
ok
28010
UNLIMITED
AREA
OK
1 Warehouse
S -2
ok
5862
UNLIMITED
AREA
OK
TOTAL FOR FLOOR
33872
UNLIMITED
AREA
OK
, B1 Mechanical Room
B
ok
400
UNLIMITED
AREA
OK
TOTAL FOR FLOOR
400
UNLIMITED
AREA
OK
BUILDING TOTAL
35072
UNLIMITED
AREA
OK
-- Sec. 503, 504, 506
and Table
503
Allowable area calculations are based on the most restrictive use.
Different uses are not separated by fire barriers. -- Sec. 302..3.2
Basement area not included in the total when checking allowable area.
-- Sec. 503.1.1
Page # 3
Code review for:
Project Id.: ASB Mail Room
Address: 525 S Center
* These walls may be required to have a parapet wall 30 inches
above the roofing. The parapet wall is required to have the
same fire rating as the wall and shall have noncombustible faces
for the uppermost 18 inches. -- Sec. 704.11
Exceptions:
The parapet wall is not required where: -
1. The roof is construction is at least 2 hour fire resistive.
2. The roof including the deck and supporting construction is
constructed entirely of noncombustible materials.
3. Exterior wall is required to be 1 hour fire resistive and
where the roof is constructed per Exception 4.
(1 hour roof /ceiling, no openings in the roof near the exterior
wall and Class B covering)
FIRE RES
ELEMENT
Structural Frame
.�. Interior Bearing wall
Interior nonbrg wall
Shaft Enclosure
Floor /Ceiling Assembly
Roof /Ceiling Assembly
ISTANCE RATINGS FOR BUILDING ELEMENTS -- Table 601
MATERIAL RATING NOTES
Any 0 hour
Any
Any
Any 1 hour Note 1
Any nr
Any 0 hour
NOTES:
1. Fire resistance rating for shafts based on Section 707.4
NOTE: See Section 707.2 for shaft enclosure exceptions.
6. Sprinkler System has been used to substitute for 1 hour fire ratings.
-- Table 601, d
SHAFT REQUIREMENTS:
Openings other than those necessary for the purpose of the shaft
shall not be permitted. -- Sec. 707.7.1
Penetrations other than those necessary for the purpose of the shaft
shall not be permitted. -- Sec. 707.8.1
Shafts that do not extend to the bottom of the building shall:
1. Be enclosed at the lowest level with the same fire- resistance
rating as the lowest floor but not less than the rating
of the shaft enclosure; or
2. Terminate in a room having a use related to the purpose of the
shaft. The room and openings shall have a fire - resistance
rating at least equal to the shaft enclosure; or
3. Be protected by approved fire dampers installed at the lowest
floor level within the shaft enclosure.
-- Sec. 707.11
Code review for:
Project Id.: ASB Mail Room
Address: 525 S Center
Page # 5
FLOOR %CEILING AND ROOF /CEILING ASSEMBLIES -- Sec. 711.4
Through penetrations of fire - resistive horizontal assemblies:
1. Through penetrations shall be installed as tested in an approved
fire resistance rated assembly. -- Sec. 711..4.1.1
2. Penetrations shall be protected by an approved penetration firestop
system with a minimum positive pressure differential of 0.01 inch of
water and shall have an F rating and a T rating of not less than
1 hour but not less than the required rating of the floor
penetrated. -- Sec. 711.4.1.2
Exceptions:
1. When penetrating items are steel, ferrous or copper conduits,
pipes, tubes and vents through a single concrete floor, the
annular space shall be permitted to be grout or mortar. The
minimum thickness is the thickness required to maintain the fire
rating. The maximum size of the penetrating items is equivalent
to a 6 -inch diameter and the opening is a maximum of 144 square
inches.
2. Electrical outlet boxes that have been tested for use in fire
- assemblies.
Membrane penetrations of fire - resistive horizontal assemblies:
The requirements are the same as for through penetrations.
-- Sec. 711.4.2
Exceptions:
1. When penetrating items are steel, ferrous or copper conduits,
electrical outlet boxes, pipes, tubes and vents through concrete or
masonry and the annular space is protected by an approved
penetration firestop assembly or protected to prevent the free
passage of flame and products of combustion. Such penetrations
shall not exceed an aggregate area of 100 square inches in any 100
square feet of ceiling area in assemblies without penetrations.
2. Electrical outlet boxes that have been tested for use in fire -
assemblies.
3. Sprinklers with metal escutcheon plates.
DUCTS AND AIR TRANSFER OPENINGS -- Sec. 715
Dampers shall be accessible for inspection and servicing. 715.4
Where required. -- Sec. 715.5
1. Fire walls. -- Sec. 715.5.1
2. Fire barriers -- Sec. 715.5.2 See exceptions
3. Fire partitions -- Sec. 715.5.3 See exceptions
4., Smoke barriers -- Sec. 715.5.4 (smoke damper) See exceptions
Page # 7
Code review for:
Project Id.: ASB Mail Room
Address: 525 S Center
NOTES FOR EXIT TABLE
Door swing is based on Section 1003.3.1.2.
Occupant load is based on Section 1003.2.2 and Table 1003.2.2.2.
Exit width is in inches and based on Section 1003.2.3 & Table 1003.2.3
Width shown for all areas is based on other egress components.,
Width shown for 1st floor is based on other egress components.
Width shown for other floors & basements is based on stairways.
For the minimum width of doors, see Section 1003.3.1.1.
For the minimum width of corridors, see Section 1004.3.2.2.
For the minimum width of stairways, see Section 1003.3.3.1.
Exits shall be continuous from the point of entry into the exit to
the exit discharge. Sec. 1005.2.3
EXIT SEPARATION
In areas where 2 exits are required, the minimum separation is 1/3 of
the maximum diagonal of the area or floor measured in a straight line
between exits or exit access doorways. -- Sec. 1004.2.2.1, Exception 2
Multiple means of egress shall be sized such that the loss of any one
means of egress shall not reduce the available capacity by more than
50 percent. -- Sec. 1003.2.3
EXIT SIGNS
Exits and exit access doors shall be marked by 'an approved exit sign.
Signs shall be placed where the exit or the path of egress travel is not
immediately visible. No point to be more than 100 feet from an exit sign.
-- Sec. 1003.2.10.1
Exception 1: Exit signs are not required in rooms or areas which require
only one exit.
Exception 2: Main exterior exit doors which obviously and clearly are
identifiable as exits need not be signed when approved.
Exit signs shall be internally or externally illuminated.
-- Sec. 1003.2.10.4
Exit sign shall be illuminated at all times including during loss of
primary power. -- Sec. 1003.2.10.5
Page # 9
Code review for:
Project Id.: ASB Mail Room
Address: 525 S Center
BUILDING ACCESSIBILITY
1. At least 50 percent but not less than one entrance to the building and
and each separate tenant space shall comply with accessible route
provisions. -- Sec. 1105.1
2. When a building has multiple entrances that serve areas facilities
required to be accessible, at least one entrance from each area is
required to be accessible. -- Sec. 1105.2
3. Where parking is provided, accessible parking spaces hall be provided
in compliance with Table 1106.1 -- Sec. 1106..1
4. At least one accessible route shall connect each accessible level.
-- Sec. 1104.4 See exceptions.
5. Where floor levels are required to be connected by an accessible route,
and an interior path of travel is provided, the accessible route shall
also be interior. -- Sec. 1104.5
6. On floors where drinking fountains are provided, at least 50 percent,
but not less than one fountain shall be accessible. -- Sec. 1108.5
ROO FZNG REQUIREMENTS:
1.oThe roofing on this building is required to be Class C. -- Table 1506.1
AUTOMATIC SPRINKLER SYSTEMS:
If openings are not provided in each 50 feet on at least one exterior
wall or there is floor area more than 75 feet from an exterior opening,
an automatic sprinkler system is required. -- Sec. 903.2.12.1
Openings shall have a minimum dimension of 30 inches. There must be at
least 20 sq.ft. of opening in every 50 lineal feet of wall or fraction
thereof.
NOTE: Openings must be entirely above the adjoining ground level.
WARNING: -- If any of the above require a sprinkler system throughout
the building, then the sprinkler system cannot be used for one hour
substitution. -- Table 601, Note 4
STANDPIPE AND HOSE SYSTEMS -- Sec. 905
A standpipe system is not required.
Code review for:
Project Id. ASB Mail Room
Address: 525 S Center
Page # 11
WALL AND CEILING FINISH:
1. Wall and ceiling finish materials are required to comply with
Sec. 803.4 and Table 803.4.
2. Textile wall coverings shall have Class A flame spread index and
shall be protected by automatic sprinklers or meet the criteria in
Section 803.5.1.1 or 803.5.1.2. -- Sec. 803.5.1
3. Carpet and similar textile materials used as a ceiling shall have a
Class A flame spread index and be protected by automatic sprinklers.
-- Sec. 803.5.2
4.. Expanded vinyl wall coverings shall comply with the requirements for
textile wall and ceiling materials. -- Sec. 803.6
5. Toilet room floors shall have a smooth, hard nonabsorbent surface
that extends upward onto the walls at least 6 inches.
- Sec. 1209.1
6. Walls within 2 feet of urinals and water closets shall have a smooth,
hard nonabsorbent surface, to a height of 4 feet above the floor.
-- Sec. 1209.2
INSULATION NOTES:
1. Insulating materials shall have a flame- spread rating of no more than
25 and a smoke developed index of not more than 450. -- Sec. 718.2
(concealed installation) and Sec. 718.3 (exposed installation)
2. Where such materials are installed in concealed spaces, the flame
spread and smoke developed limitations do not apply to facings,
coverings and layers of reflective foil that are installed behind
and in substantial contact with the unexposed surface of the
ceiling, wall or floor finish. -- Sec. 718.2.1
Foam plastic insulations are required to be protected. -- Sec. 2603
ADDITIONAL REQUIREMENTS:
For B occupancy
For S -2 occupancy
Code review for:
Project Id.: ASB Mail Room
Address: 525 S Center
Page # 13
5. Grab bars shall have a circular cross section with a diameter of
1 1/4 inch minimum and 2 inches maximum, or shall provide
equivalent graspability. -- Sec. 609.2
The space between the wall and the grab bar shall be 1 1/2 inches.
Sec. 609.3
Grab bars shall be mounted in a horizontal position 33 inches
minimum and 36 inches maximum above the floor. -- Sec. 609.4
a. Side wall grab bars are required to start within 12 inches
of the backwall and extend to 54 inches from the back wall.
(The minimum length of the bar is 42 in) -- Sec. 604.5.1
b. The rear bar shall be 24 in long minimum, centered on the
water closet. Where space permits, the bar shall be 36 in
long minimum, with the additional length provided on the
transfer side. -- Sec. 604.5.2
6. The top of the water closet seats shall be 17 to 19 inches above
the floor. -- Sec. 604.4
7. Accessible urinals shall be of the stall type or wall hung with
the rim at 17 inches maximum above the floor. -- Sec. 605.2
8. Accessible lavatories shall be mounted with the rim 34 inches
maximum above the floor. -- Sec. 606.3
9. Sinks shall be 6 1/2 inches deep maximum. -- Sec. 606.5
10. Water supply and drain pipes under lavatories shall be
insulated or otherwise treated to protect against contact.
- Sec. 606.6
11. Mirrors shall be mounted with the bottom edge of the reflecting
surface 40 inches maximum above the floor. -- Sec. 603.3
8 Oct. 2004
BYU -Idaho Mailroom Remodel - Plan Review Response
TOPIC COMMENT RESPONSE
� � oo3ss
R E C E 0 W
OCT 1 , 2004
CITY OF REXBURG
Structural has been reviewed by Rulon Nielsen
Structural Review
but stap was not done. Plans to be stamped
These two copies have architect's stamp
before pe rmit issued
Stamped plan show existing location on south
Fire Extunguishers
Plans do not show fire extinguishers
wall & new location on west wall (SheetA2 -3)
Alarm system will need to be brought up to
Stamped plan shows existing pull station &
Alarm Systems
current codes. Please submit drawings,
horn /strobe location on south wall &new
calculations, etc. for approveal prior to receiving
locations for same on east wall. (SheetA2 -3)
a building permit
A lock box is required for this occupancy.
Campus personnel are currently installing lock
Other Comments
Pleasecontact the fire department for an
boxes on all buildings, campus wide.
authorization form.
Plans indicate fire suppression lines to be
Sheet A2-1, note 14 refers to this item. We
Automatic Fire
brought up to current code. Plans to be
have contracted with 3 -D Fire Sprinkler to
Extinguishing Systems
submitted and approved prior to a building
design & install the system. Plans will be
p ermit being issued.
Iforthcoming.
� � oo3ss
R E C E 0 W
OCT 1 , 2004
CITY OF REXBURG