HomeMy WebLinkAboutALL DOCS & CO - 08-00322 - Teton Radiology Madison - New Building4 1tEXBUR G I9 v o s� SB A < a > �SMED � CITY OF REX Cw America's Family Community Building INSPECTION CARD BUILDING Date Annrnved 1. Mechanical Rough In 2. Mechanical Pressure 3. Mechanical Final Ins 4. Layout 5. Footing 6. Foundation 7. Framing 8. Insulation 9. Drywall 10. Sidewalk 11. Final ELECTRICAL Date Annroved This permit is issued subject to the regulations contained in Building Code and Zoning Regulations of the City of Rexbug. It is specifically understood that this Permit does not allow any Variance to the regulations of the City of Rexburg or Zoning Codes unless specifically approved by the City Council and explained on the Building Permit Application as approved by the Building Inspector. Date Approved 9/[61 101K Issued B Building Inspector 1. Groundwork/Ufer 2. Rough -In 3. Electrical Temporary 4. Electrical Service 5. Final OTHER Date roved 1. Fire Department Fine 74 W n p p r kA ^# .on THIS PERMIT MUST BE PROMINANTLY DISPLAYED AT THE BUILDING SITE THE BUILDING MAY NOT BE OCCUPIED OR USED WITHOUT FIRST OBTAINING ACERTIFICATE OF OCCUPANCY 1) A complete set of approved drawings along with the permit must be kept on the premises during construction. 2) The permit will become null and void in the event of any deviation from the NOTICE! accepted drawings. 3) No foundation, structural, electrical, nor plumbing work shall be concealed without approval. No work shall H° - on- nr any part of the building b:: the point indicated in each successive inspection without approval. No structural framework of any underground work shall be covered J Permit Number required -ke inspection appointments K For Inspections Can '0 20 option 2 ACERTIFICATE OF OCCUPANCY CAN NOT BE ISSUED PRIOR TO FINAL ELECTRICAL & PLUMBING INSPECTION ~;o gBXBUgc,9 u.� o HFD CITY OF Certificate of Occupancy REX America's Family community Building Permit No: Applicable Edition of Code: Site Address: Use and Occupancy: Type of Construction: Design Occupant Load: Sprinkler System Required: Name and Address of Owner: City of Rexburg Department of Community Development 19 E. Main St. / Rexburg, ID. 83440 Phone (2081359 -3020 / Fax (2081359 -3024 0800322 International Building Code 2006 433 E 4th N Teton Radiology Madison Type V, non -rated 107 No Teton Radiology Diagnostic Llc 2440 E 25th C i r Idaho Falls, ID 83404 Contractor: Special Conditions: Okland Construction Occupancy: Business - office, professional or service transactions This Certificate, issued pursuant to the requirements of Section 109 of the International Building Code, certifies that, at the time time of issuance, this building or that portion of the building that wes inspected on the date listed vies found to be in compliance with the requirements of the code for the group and division of occupancy and the use for which the proposed occupancy wes classified. Date C.O. Issued: July 08, 20 ; 1 C.O Issued by: Building Official There shall be no further change in the e)asting occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and approved said future changes. Plumbing Inspector: Fire Inspecto Electrical Inspector: f PBZAdministrator: 1 0 4 CITY OF REXB URG BUILDING PERMIT APPLICATION; Pleas( 08 00321 & 00 00322 19 E MAIN, REXBURG, ID. 83440 208 -359 -3020 X326 PARCEL NUMBER ( W e win prociae MIS ror you) SUBDIVISION,?: UNIT# BLOCK# (Addressing is based on the information - must be accurate L4# OWNER NAME• MY+�llp,. LL t CONTACT PHONE PROPERTY ADDRESS:-..4 �,. �7s F„ ge*k✓, r 12 ,; y., PHONE #:.Home ( ) Work let) b- 3J�q I Cell (2a8) -3t3 -23�� OWNER MAILING ADDRESS `iSo c. 04,, �j CITY: b,i STATE: QD ZIP: n EMAIL dt � ' 1S APPLICANT: (If other than owner) (Applicant if other than owner, a statement authorizing applicant to act as agent for owner must accompany this application.) APPLICANT INFORTNIATION: ADDRESS CITY: STATE; ZIP EMAIL FAX PHONE #: Home ( ) Work ( ) Cell ( ) MAILING ADDRESS: 19 }_�sr CI1"Y SA L,+kIL� / +N. STATE Lk ZIP_SADs PHONE: Cell# Zo8- �� - e� 3 Z work# 2PR - ?�,Sq- /�P�t Z. Fax # Zj2Z - 3,5* i hMATT ---- d4ad,( DAHO REGISTRATION # & EXP. DATE 1 I$45' How many buildings are located on this property:? 1 Did you recently purchase this property? No < es (If yes give owner's nanle /VI T �,� r, t z ) �— � � - --`7r y � �I > LLi— Is this a lot split? XQ YES (Please bring copy of new legal description of property) PROPOSED USE: 11� 1 ,,. e (i.e., Single Family Residence, Multi Family, Apartments, Remodel, Garage, Commercial, Addition, Etc.) APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: under perwr of periur,:, I hereb certify that I have mad this apph on and stat hat the information herein is correct and I swear that any information which may hereafter be haven by me in hearings before the ]'tanning and Z ng Commission or e City Council for the City of Rexburg shall be truthful and correct I agree to comply with all City regulations and State ]arcs relating to the for inspections purposes. NOTE: subject after of tlris application d hereby authorized representatives of the Gtr to enter upon the above- mentioned property The building o uiai may revok a perm on approval issued under the provisions of the 2003 International il Code in cases of any false statement or misrepresentation of faro in the applicatio r on the pl on xvi ' the permit ev approval u es based. Permit void if not started within 180 days. Permit void if work stops for 180 days. � a Signatu e of Ch er /Applicant Do you prefe to be contacted by fax, email or phone? 'rcle One DATE ^ WARNING — BUILDING PERMIT MUS E POSTED ON CONSTRUCTION SITE! 1 Plan fees are non - refundable and are paid in full a the time of application beginning antrarXZ 2005 City of Rexburg's Acceptance of the plan review fee does not constitute plan approval * *Building Permit Fees are due at time of application" * *Building Permits are void if your check does not clear ** 2 Building Safety Department City of Rexburg >a 19 E Main ionellh@rexburg.org Phone: 208.359.3020 x326 ID 83440 www.re xburg.org Fax: 208.359.3024 CIT OF .,R America's Fwnily Community Remodeling Your Building /Home (need Estimate * �3 , SURFACE SQUARE FOOTAGE: (Shall include the exterior wall measurements of the building) First Floor Area ((, 50O Second floor /loft area Third floor /loft area Shed or Barn Water Meter Quantity Unfinished Basement area Finished basement area Garage area Carport/Deck (30" above grade)Area Water Meter Size: 2 " Required!!! PLUMBING Plumbing Contractor's Name: V k&t, Wt i _ Business Name: Mile &tKfc,j A (,Jeff- Mec(, Address 7.336 I.J S 2 do 5. City qM�State � r,> - zip Y Y P 83 0 Contact Phone: (Zo$) 3SG - p3 *d Business Phone: ( w$ 1, Email {M +ntiJSt'WL�A VtOQ GOIM Fax tag -356 - 02Y FIXTURE COUNT Cincludin roughed fixtures) Clothes Washing Machine Dishwasher Floor Drain Garbage Disposal Hot Tub /Spa Sinks (Lavatories, kitchens, bar, mop) Sprinklers Tub /Showers _ Toilet /U E E Water He Water So SEP 1 6 2008 I CITY OF RE XBURG Plumbing Estimate $ -200, 0 e o (Commercial Only) _ G Cl is 8 Required! Signature of Licensed Contractor License number Date c ♦ g +a CITY OF ■t !'� YImo► R _ Building Safety 19 E Main janellh @rexburg.org Rexburg, ID 83440 www.rexburg.org OWNER'S NAME 'AA Fot�i�il -tPc 3�tt.. PROPERTY ADDRESS Wk E, c 2exl o SUBDIVISION �JA.Gk c.• ot� y7,. PHASE LOT y, 5 - L BLOCK 0 Department City of Rexburg Phone: 208.359.3020 x326 Fax: 208.359.3024 Permit# Require !! MECHANICAL Mechanical Contractor's Name: Mar (i H 14, 11 Business Name: Address Z 33 (P - 1-j S l&O 5. City F State T Zip -lqo Contact Phone: (Zoj) 35'6 -037o Business Phone: (20%) 3rS6 n 3 *0 Email V461 W6 9 ptUto. uik Fax 20 -Fri- '9 Mechanical Estimate $ pp oo d (Commercial /Multi Family Only) FIXTURES & APPLIANCES COUNT (Single Family Dwelling Only) Furnace Exhaust or Vent Ducts Furnace /Air Conditioner Combo Heat Pump Air Conditioner Evaporative Cooler Unit Heater Space Heater Decorative gasfired appliance Incinerator System Boiler Pool Heater Dryer Vents Range Hood Vents Cook Stove Vents Bath Fan Vents other similar vents & ducts: Fuel Gas Pipe Outlets including stubbed in or future outlets Inlet Pressure (Meter Supply) PSI Heat (Circle all that apply) Gas Oil Coal Fireplace ElectrHydronic Required! Signature of Licensed Contractor IECEIUE SEP 1 u 2008 License number ,?/, Z/d S/ b Date Building Safety Department City of Rexburg CITY OF REXBURG U 7 5 CITY o f R ..►..t 1./ V ...,.____.._____...., tom.._____ ----- BuiAg Safety Department City of Rexburg 19 E Main jonellh @rexburg.org Phone: 208.359.3020 x326 Rexburg, ID 83440 www.rexburg.org Fax: 208.359.3024 U � CITY OF REXBURG Ow America's Family Community OWNER'S NAME PROPERTY ADD RESS u 33 6 4 - r SUBDIVISION PHASE LOT BLOCK Permit# in � z Z, Require&ff Electrical Contractor's Name r ELECTRICAL sTv� 4ti /l )0i) c ✓LG 4a cc D 0Yo, 1; ,r eC' Business Name _City IT/�ol� State Zip 102 Cell Phone ( ) b Y ~ O � Business Phone ( ) 5 7 / Fax ( ) 5-Z q y y Email 4 A4 S 7 e /� C Ck f� L - CO Q Electrical Estimate (cost of wiring &labor) $ 3Gb, 0 � (COMMERCIAL /MULTI - FAMILY ONLY) (Includes the cost of materials installed regardless of the party suppling it). TYPES OFINSTALLATION (New Residential includes everything contained within the residential structure and attached garage at the same time) RESIDENTIAL ONLY ❑ *Up to 1,500 sq ft - $72 ❑ *1,501 to 2,500 sq ft- $120 ❑ *2,501 to 3,500 sq ft - $168 ❑ *3,501 to 4,500 sq ft - $216 • * *Over 4,500 sq ft - $216 plus $.04 /sq ft: sq • Existing Residential (# of Branch Circuits) - $40 plus $10 per circuit: ft total # of circuits ❑ Temporary Construction Service, 200 amp or less, one location (for a period not to exceed 1 year) - $40 ❑ Spa, Hot Tub, Swimming Pool - $40 plus $40 grounding grid where applicable • Electric Central Systems Heating and /or Cooling (when not part of a new residential construction permit and no additional wiring) - $40 • Modular, Manufactured or Mobile Home - $50 plus $10 per circuit • Other Installations: Wiring not specifically covered by any of the above: Cost of Wlinng & Labor $ (I ncludes the cost of materials installed regardless of the party suppying it). • Pumps (Domestic Water, Irrigation, Sewage): horse power ❑ Requested Inspections (of existing wiring) - $40 /hr (1 hr minimum) plus $40 /hr thereafter *Includes a maximum of 3 inspections. Additional inspections charged at requested inspection rate of $40 per hour. ** Includes a maximum of 4 inspections. Additional inspections charged at requested inspection rate of $40 per hour. C % y3 t Z, % O Signature of Licensed Contractor License number Date �71 OWNER'SNAME M Vk -Fcy,!(L -80 PROPERTY ADD -SS q N . 4 LS SUBDIVISION V u % i t« , AJ64 do,; � PHASE LOT `+�_ BLOCK 4 P Pen 408 00322 Teton Radiology Madison 433 E 4th N Required!!! ELECTRICAL ElectricalContractoi' Name ulx" Ay A tm,, Business Name ,4 nu sfrmv4 Oec r.L . A,— 2o 2.S' TkLtM b w ll Co. City 9 &(, 4�4 State T/7 Zip g 5 i CellPhone (249) SZSr- j! jj Z Business Phone (209) S"Z `/ , &I Z Fax (?,d%) 5 Zq - f5Y ?!Z Email Electrical Estimate (cost of wiring & labor)$ N 41 r l (Includes the cost of mai®as6llled regardless of the party sul TYPES OF INSTALLATION (New Residential includes everything contained within d.. RESIDENTIAL ONLY ❑ *Up to 1,500 sq ft $72 ❑ *1,501 to 2,500 sq ft $120 ❑ *2,501 to 3,500 sq ft- $168 ❑ *3,501 to 4,500 sq ft $216 ❑ * *Over 4,500 sq ft $216 plus $.04 /sq ft: sq ft total • Existing Residential (# of Branch Circuits) $40 plus $10 per circuit: # of circuits • MultiFamily Only: # of units per building$120 /bldg + $60 /unit ❑ Services: Alterations /Repairs that require utility disconnection. (Estimate applicable for commercial). Temporary Construction Service, 200 amp or less, one location (for a period not to exceed 1 y$A4 ❑ Spa, Hot Tub, Swimming Poel$40 plus $40 grounding grid where applicable • Electric Central Systems Heating and/or Coolikhen not part of a new residential construction permit and no additional wirino0 • Modular, Manufactured or Mobile Hora650 plus $10 per circuit • Other Installations: Wiring not specifically covered by any of the above: Cost of Wiring & Labor: $ (In cludes the cost of materials installed regardless of the party • Pumps (Domestic Water, Irrigation, Sewage): horse power ❑ Requested Inspections (of existing wiring) $40 /hr (1 hr minimum) plus $40 /hr thereafter ❑ Temporary Amusement /Industr-y$40 plus $10 per ride, concession or generator *Includes a maxinum of 3 inspections. Additional inspections charged at requested inspection rate of $40 per hour. *'F Includes a maximum of 4 inspections. Additional inspections charged at requested inspection rate of $40 per hour. zqt.. , J� /,)- — 6 z � � - -r l q c 3l �lo 8: Signattre of Licensed Contr ctor License number Ti nte Building Safety Department City of Rexburg CITY o P REXBUR rtmtT, ica' Family Community 79 E. Main Rexbura, ID 83440 jonellh @rexburg.org www.rexbura.ora Phone: 208.359.3020 Fa x: 208.359.3024 d xe ' I TEMPORARY OWNER'SNAME 04 M K - Foei (;�Q T PROPERTY ADD SS Ltr= ^J . y 2 e t. SUBDIVISION W V. I to I 14,A he.-I A to A PHASE LOT 4( S6 BLOCK 00322 ` 4 33 E 4th N Required!!! ELECTRICAL Electrical Contractoig Name I, aL, Business Name A ulc s+yh,4 67EehtL Address Zo2.f' T6,rm kwil bI: State T17 Zips P ya l CellPhone (2dq) 5L 'V. ! FaZ Business Phone (2P4) 6 _ F1gZ Fax (z&%) 5' 7_q _ 'AAy ?Z Email Electrical Estimate ( cost of wiring & labor)$ N 41 , (Includes the cost of maucasbllled regardless of the party sul TYPES OF INSTALLATION (New Residential includes everything contained within d RESIDENTIAL ONLY • *Up to 1,500 sq ft $72 ❑ ^ 1,501 to 2,500 sq ft $120 • ' 2,501 to 3,500 sq ft $168 ❑ ^'3,501 to 4,500 sq ft $216 • "Over 4,500 sq ft - $216 plus $.04 /sq ft: sq ft total ❑ Existing Residential (# of Branch Circuits) $40 plus $10 per circuit: # of circuits ❑ MuhfFamily Only: # of units per building$120 /bldg + $60 /unit ❑ Services: Alterations /Repairs that require utility disconnection. (Estimate applicable for commercial). Temporary Construction Service, 200 amp or less, one location (for a period not to exceed 1 Yffi44 • Spa, Hot Tub, Swimming Poel$40 plus $40 grounding grid where applicable • Electric Central Systems Heating and/or Cooli(vghen not part of a new residential construction permit and no additional wir0 • Modular, Manufactured or Mobile Homt$50 plus $10 per circuit ❑ Other Installations: Wiring not specifically covered by any of the above: Cost of Wiring & Labor: $ (In cludes the cost of materials installed regardless of the party ❑ Pumps (Domestic Water, Irrigation, Sewage): horse power ❑ Requested Inspections (of existing wiring)$40 /hr (1 hr minimum) plus $40 /hr thereafter ❑ Temporary Amusement /Industny$40 plus $10 per ride, concession or generator *Includes a maxinum of 3 inspections. Additional inspections charged at requested inspection rate of $40 per hour. Includes a mammum of 4 inspections. Additional inspections charged at requested inspection rate of $40 per hour. z .7. 10 , J� //) - r lyjlZ i o8 Signatwe of Licensed Contr ctor License number Ti nti.. Building Safety Department City of Rexburg CITY of XB CW A me laze Family Community 79 E. Main Di.4 -- 1! OOA All janellh@rexburg.org Phone: 208.359.3020 r...... - - 7/1!1 A 04110 APPLICATION: "CONSTRUCTION PERMIT" CONSTRUCTION PERMIT #: PERMIT APPROVED: YES/ NO $50.00 FEE PAID: YES /NO - APPLICANT INFORMATION: APPROVED BY: Business Name: k w 04 fin; 1 s Office Address 10 c _ ,,on,• Wi t? - .ti n 1974440 city State Zip Office Phone Number ( Contractor Performing the Work: Contact Person - LOCATION C rCBE DONE: Cell Phone# U 62o - o432 Street Address Where Work Will Be Done H n' N 4 t2e - E Business Name Where Work Will Be Doe: Dates For Work To e Donee. 15 To Contact Person: Phone Number: (Z&S) 35� . 491 z, _ Cell # ze 6 to - oq S L PLEASE CHECK THE TYPE OF PERMIT(S) YOU ARE APPLYING FOR: AUTOMATIC FIREEXTINGUISHING SYSTEMS COMPRESSED GASES YC FIRE ALARM AND DETECTION SYSTEMS AND RELATED EQUIPMENT FIRE PUMPS AND RELATED EQUIPMENT FLAMMABLE AND COMMBUSTIBLE LIQUID V M L HAZARDOUS MATERIALS INDUSTRIAL OVENS EP 1 6 2008 LP -GAS PRIVATE FIRE HYDRANTS � ��Ty OF REXBURG SPRAYING OR DIPPING STANDPIPE SYSTEMS TVvfPQRARY MEMBRANE STRUCTURES, TENTS, AND CANOPIES `�� App ican s Signature Date 0 • SUBCONTRACTOR LIST Excavation & Earhwork: �,,,,, �, 80 Concrete: L- ke (e &A c Masonry: (,),r. Roofing: F- db+Sd v Insulation: f�a � Drywall: Painting: Floor Coverings: tsa 7 j 1G, Plumbing: Heating: �JU1 �,,� os+. WA4� � Electrical: Special Construction (Manufacturer or Supplier) Roof Trusses: rs,/�(!'fd h r 9 t? dean Floor /Ceiling Joists: Siding /Exterior Trim: Other: E C E 0 V SEP l 6 2008 CITY OF REX Design Standards for structures less than 25,000 square feet. Note: Please see Rexbures Development Code for design standards for structures over 25,000 square feet, or for developments located in the Neighborhood Business District or Central Business District zones. Please demonstrate how vour project meets the following requirements: Developments with facade over 40 feet in linear length shall incorporate wall projections or recesses a minimum of 3 foot depth and a minim of g contiguous feet within each 40 feet of facade length and shall extend over 20 percent of the facade. All sides of a structure clearly visible from a public street shall be so treated. Developments shall use animating features such as arcades, display windows, entry areas, or awnings along at least 60 percent of the facade. The entry facade facing the street is articulated with an entry canopy that extends approximately 34'-0" beyond the building a rticulating wall plains and chimney mass that breakdown the scale of the building and give clear definition and depth to the facade. The west facade has a canopy extension of the roof and is articulated with repetitive steel struts, material changes & roof changes. The east & rear facades are treated with repetitive steel struts, material & roof height changes, and create a nice 3 dimensional rhythm to the facade. Large roof overhangs give the building shade and shadow for a soft integration with the horizontal ground plain. Where principal buildings contain additional, separately owned stores, which occupy less than twenty-five thousand (25,000) square feet of gross floor area, with separate, exterior customer entrances: a. The street level facade of such stores shall be transparent between the height of three feet and eight feet above the walkway grade for no less than 60 percent of the horizontal length of the building facade of such additional stores. N ot applicable to this building. b. Windows shall be recessed and should include visually prominent sills, shutters, or other such forms of framing. T he storefront windows are set into prominent horizontal aluminum frames with minimal vertical frames to enhance the horiz ch aracter of the building. They are also framed and recessed into brick walls and thick set cement panel sills All of the punc windows ar framed and recessed Into brick wa lls and thick set cement panel sills. Building facades shall include a repeating pattern that shall include no less than three of the elements listed below. At least one of theses elements shall repeat horizontally. All elements shall repeat at intervals of no more that thirty (30) feet, either horizontally or vertically. -Color change - Texture change - Material module change - Expression of architectural or structural bay through a change in plane no less than 12 inches in width, such as an offset, reveal, or projecting rib. The building n .h iv s th se goals The h;a of th h iilding is defined by an art cement panel wainccot that create a strong horizontal band and will reflect a cut stone pattern The wainscot willprqject proud of the brick above The texture and colo of the brick, c ement panel wainscot and projecting steel struts shall express the architectural/ structural bay. The three materials will ha rmonize and enhance the buildino. The concrete will be a natural color and the brick will be dark red or an earthtone as selected by the Owner. Roof lines shall be varied with a change in height every 100 linear feet in the building length. Parapets, mansard roofs, gable roofs, hip roofs, or dormers shall be used to conceal flat roofs and roof top equipment from public view. Alternating lengths and designs may be acceptable and can be addressed during the preliminary development plan. T his is acheived with a combination of a shallow barrel vault roof and a shallow hip roof set at two different height Predominant exterior building materials shall be high quality materials. These include, without limitation: -Brick -Wood - Sandstone -Other native stone - Tinted, textured, concrete masonry units The exterior materials include brick (dark red or natural earthtone as selected by Owner) and CemClad cement panels tha are set in a running bond pattern and grouted with silicone grout to emulate cut stone Facade colors shall be low reflectance, subtle, neutral, or earth tone`colors. The use of high intensity colors, metallic colors, black or fluorescent colors is prohibited. All colors shall be earthtone. Samples can be provided if desired. Building trim and accent areas may feature brighter colors, including primary colors. Neon tubing shall not be an acceptable feature for trim or accent. B uilding trim shall be baked enamel or powder coated steel in a dark bronze or other earthtone color as selected by Owner Predominant exterior building materials as well as accents shall not include the following. - Smooth -faced concrete block - Tilt -up concrete panels without mitigating surface treatment - Pre - fabricated steel panels None of these materials are used and none of our materials would appear like them 0 • Each principal building on a site shall have clearly defined, highly visible customer entrances featuring no less than three of the following: - canopies or porticos - overhangs -recesses/projections - arcades - raised corniced parapets over the door - peaked roof forms - arches - outdoor patios - display windows - architectural details such as file work and moldings which are integrated into the building structure and design - integral planters or wing walls that incorporate landscape areas and /or places for sitting T his building includes two canopies large projecting overhangs with struts that mimic arcades a large shall arch (i.e. barrel vault), large display windows and detailed stone -like wainscot with articulation in the brick work by striking the vertical joints and raking the horizontal ioints. No more that 60 percent of the off - street parking area for the entire property shall be located between the front facade within the front yard of the principal building(s) and the primary abutting street unless the principal building(s) and /or parking lots are screened from view by out -lot development (such as restaurants) and additional tree plantings and /or berms. P arking was previously reviewed with the City Planning Department and adjustments were made to accommodate the Plan ner's r ecommendations. The parking will be significantly landscaped with trees undulating ground forms to respect drainage and flood p lain elevation requirements. Nicely done drainage swells and berms will screen the parkinq as well a large landscaped isla w ithing the parking area. Parking shall be located to the rear of the building or screened so that it does not dominate the streetscape. Fences, hedges, berms and landscaping shall be used to screen parking areas. When large parking lots are necessary, increase the landscaping to screen the lot and divide the lot into smaller components. Landscape islands must be provided in the interior of large lots. These may double as snow storage areas in the winter months. Approximately 37 % of the parking is located toward the rear of the building Landscaping with berms and large islands is u sed t o screen all of the oarking areas The minim setback for any building facade shall be in accordance with the requirements for all Commercial zones, except Community Business Center. Where the facade faces adjacent residential uses an earthen berm shall be installed, no less than 6 feet in height, containing at a minimum, a double row of evergreen or deciduous trees planted at intervals of 15 feet on center. Additional landscaping may be required by the Planning Commission to effectively buffer adjacent land use as deemed appropriate. Any and all additional landscape requirements of all the Commercial zones, except Central Business District, shall apply. T he building meets the required setbacks There are no adjacent residential properties 0 0 Areas for outdoor storage, truck parking, trash collection or compaction, loading, or other such uses shall not be visible from public or private rights -of -way. T Jae_dumnte is sPt toward the hank of the cite withino an interinr InodsrapPed parking lot isl nd and screened by a brick wa t o match the building The loading zone and trash collection area are sc reened by these same elements No areas for outdoor storage, trash collection or compaction, loading, or other such uses shall be located within 20 feet of any public thoroughfare of street, public sidewalk, or internal pedestrian way. T he loading and trash areas are set to the rear of the site away from neighbors and easements and are screened by lands caping and architectural features. Loading docks, truck parking, outdoor storage, utility meters, HVAC equipment, trash dumpsters, trash compaction, and other service functions shall be incorporated into the overall design of the building and the landscaping so that the visual and acoustic impacts of these functions are fully contained and out of view from adjacent properties and public streets, and no attention is attracted to the functions by the use of screening materials that are different from or inferior to the principal materials of the building and landscape. ; VUM"YEILS , U "1 - rY M151 L b /Ac- F .Q VIP MF_NY. E NAJfz AL-L REEN x� R.e.mnIZ p u 1 7sr— IGle�L-r-S 7o MA,YGfI 7HIE WL�NC� 47f— 1, SGi4P MA�tk&I L. ,dLL OF 'y!3 SK ?EMS XR-E 4yr 'Yvw .le.fl !40r. &ZAr. O This IVILflINk 51`17E Y�0 LoN F.,A, 'T�}LM �rE 7 E S'yRLET.4,ND ,$ �jJ. L UNY pRaPE�T1ES . Non - enclosed areas for the storage and sale of seasonal inventory shall be permanently defined and screened with walls and /or fences. Materials, colors, and designs of screening walls and /or fences and the cover shall conform to those used as predominant materials and colors of the building. If such areas are to be covered, then the covering shall conform to those used as predominant materials and colors on the buildings. N ot applicable to this project. Temporary sales /displays, such as Christmas trees, landscape materials, and fireworks, shall follow all outdoor requirements for all the Commercial zones, except Community Business Center, as described in the Development Code. Location and time /duration of such sales /displays shall be reviewed and approved by the Community Development Director or appointed designee. N ot applicable to this project. Sidewalks at least six (6) feet in width shall be provided along all sides of the lot that abut a public or private right - of -way, excluding interstates. The Planning Commission may waive this requirement as part of a development agreement. A side walk meeting these requirements is located along the street frontage of this project • • Continuous internal pedestrian walkways, no less than five (5) feet in width, shall be provided from the public sidewalk or right -of -way to the principal customer entrance of all principal buildings on the site. At a minim walkways shall connect focal points of pedestrian activity such as, but not limited to, transit stops, street crossings, building and store entry points, and shall feature adjoining landscaped areas that include trees, shrubs, benches, flower beds, ground covers, or other such materials for no less than 50 percent of their length. One internal pedestrian walkway has been provided to connect the main entry to the furthest parking area This walkway is set in continous landscaping to make it attractive. No other internal walkways appear to be needed as the paved areas for parking seem to be adequate to allow all pedestrians reasonable access to the entries of the building. Sidewalks, no less than five (5) feet in width, shall be provided along the full length of the building along any facade featuring a customer entrance, and along any facade abutting public parking areas. Such sidewalks shall be located at least six (6) feet from the facade of the building to provide planting beds for foundation landscaping, except where features such as arcades or entryways are part of the facade. Sidewalks have been placed along the south and west farnrlps of the h wilding to meet the required widths and have been a et away from the building to create planting areas between the building and the sidewalks. Internal pedestrian walkways provided in conformance with Subsection b above, shall provide weather protection features such as awnings or arcades within thirty (30) feet of all customer entrances, constructed parallel to the facade of the building. This is not intended to extend into the driving aisles or parking areas. B oth customer entrances of this project are covered by large canopies All internal pedestrian walkways shall be distinguished from driving surfaces through the use of durable, low maintenance surface materials such as pavers, bricks, or scored concrete to enhance pedestrian safety and comfort, as well as the attractiveness of the walkways. Signs shall be installed to designate pedestrian walkways. A ll internal pedistrian walkways shall be constructed of scored concrete and appropriate signaqe will be placed to designat s uch walkways. Each commercial establishment subject to these standards shall contribute to the establishment or enhancement of pedestrian and public spaces by providing at least two (2) of the following: patio /seating area, pedestrian plaza with benches, transportation center, window shopping walkways, outdoor play area, kiosk area, water feature, clock tower, steeple, or other such deliberately shaped area and /or a focal feature of amenity that, in the judgment of the Planning Commission, adequately enhances such Community and public spaces. Any such areas shall have direct access to the public sidewalk network and such features shall not be constructed of materials that are inferior to the principal materials of the building and landscape. SINGS 71 15 PRO -1 —� SPE Mr>le-AL FAG)w ] 7 WOVI-D 5 sa " 1.sL - 774E LAt- )b5" S1D�wrlL -KS woVQ BE 5v�Jc1EN:& 1F 17' 15 N,K cS5AAY WE G� ZAgJ 7o t` s7 " U4: 50M E F -AAluR ry Ml< - r A Le U I IZFNl F N T U.S. DEPARTMENT OF HOMELAND SECURITY 'Federal Emergency Management Agency National Flood Insurance Program ELEVATION CERTIFICATE Important: Read the instructions on pages 1 -8. OMB No. 1660 -0008 Expires February 28. 2009 _ SECTION A - PROPERTY INFORMATION For Insurance Company Use: Al. Building Owner's Name Teton Radiology Policy Number A2. Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. Company NAIC Number 4` North St. - Address not yet assigned City Rexburg State ID ZIP Code 83440 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) Lots 5 and 6, Block 1, Walker Addition - Division No. 2 A4. Building Use (e.g., Residential, Non - Residential, Addition, Accessory, etc.) Medical / Professional A5. Latitude /Longitude: Lat. 43 °50'03 "N Long. 111 °46'17 "W Horizontal Datum: ® NAD 1927 ❑ NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number N/A A8. For a building with a crawl space or enclosure(s), provide A9. For a building with an attached garage, provide: a) Square footage of crawl space or enclosure(s) sq ft` a) Square footage of attached garage sq ft b) No. of permanent flood openings in the crawl space or b) No. of permanent flood openings in the attached garage enclosure(s) walls within 1.0 foot above adjacent grade walls within 1.0 foot above adjacent grade c) Total net area of flood openings in A8.b sq in c) Total net area of flood openings in A9.b sq in SECTION B - FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State Rexburg, City of Community No. 160098 Madison ID B4. Map /Panel Number B5. Suffix B6. FIRM Index Date B7. FIRM Panel Effective /Revised Date B8. Flood B9. Base F ) (Zone Z u a flo th) 16065CO020 D 06/03/1991 06/03/1991 4 B10. Indicate the source of the Base Flood Elevation (BFE) data or base flood depth entered in Item B9. U " ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other (Describe) !! ,yam I I 611. Indicate elevation datum used for BFE in Item 69: ® NGVD 1929 El NAVD 1988 El Oth ribe� tW � B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Are P ? ❑Yes ® o Designation Date ❑ CBRS ❑ OPA ry RE A SECTION C - BUILDING ELEVATION INFORMATION (SURVEY C1. Building elevations are based on: ® Construction Drawings* ❑ Building Under Construction* ❑ Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations -Zones Al -A30, AE, AH, A (with BFE), VE, V1 -V30, V (with BFE), AR, AR/A, AR/AE, AR/A1 -A30, AR/AH, AR/AO. Complete Items C2.a -g below according to the building diagram specified in Item A7. Benchmark Utilized IDBY -CORS Vertical Datum NAVD88 converted to NGVD29 by the NGS VERTCON program Conversion /Comments Elevation data collected utilizing IDBY is in the NAVD88 datum, subtract 3.583 feet to obtain the NGVD29 datum of the FIRM Check the measurement used. a) Top of bottom floor (including basement, crawl space, or enclosure floor)_ N /A. ❑ feet ❑ meters (Puerto Rico only) b) Top of the next higher floor N /A. ❑ feet ❑ meters (Puerto Rico only) c) Bottom of the lowest horizontal structural member (V Zones only) N /A. ❑ feet ❑ meters (Puerto Rico only) d) Attached garage (top of slab) N /A. ❑ feet ❑ meters (Puerto Rico only) e) Lowest elevation of machinery or equipment servicing the building N /A. ❑ feet ❑ meters (Puerto Rico only) (Describe type of equipment in Comments) f) Lowest adjacent (finished) grade (LAG) 4864.8 ® feet ❑ meters (Puerto Rico only) g) Highest adjacent (finished) grade (HAG) 4867.1 ® feet ❑ meters (Puerto Rico only) SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. I understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. ® Check here if comments are provided on back of form. Certifier's Name David C. Lee License Number 10897 Title Survey Manager Company Name Forsgren Associates Address 350 North 2 nd East City Rexburg State ID ZIP Code 83440 Signature Date 11116107 Telephone 208 356 - 9201 (i• FEMA Form 81 -31, February 2006 See reverse side for continuation. Replaces all previous editions IMPORTANT: In these spaces, copy the corresponding information from Section A. For Insurance Company Use: Building Street Address (including Apt., Unit, Suite, and /or Bldg. No.) or P.O. Route and Box No. Policy Number 0 North St. — Address not yet assigned City Rexburg State ID ZIP Code 83440 Company NAIC Number SECTION D - SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION (CONTINUED) Copy both sides of this Elevation Certificate for (1) community official, (2) insurance agent/company, and (3) building owner. Comments Elevation data was collected relative to the IDBY CORS with a published orthometric elevation of 4937.55 feet in the NAVD88 Datum. The existing FIRM for Rexburg Idaho was generated in the NGVD29 Datum. The NGS program "Vertcon" was utilized to convert the NAVD88 orthometric elevation of IDBY (4937.55) to the NGVD29 orthometric elevation of 4933.97 (delta from NAVD88 to NGVD29 locally = -3.58 feet). The base flood elevation for the purpose of this elevation certificate and associated property was determined from the nearest upstream flood contour as indicated on the FIRM Panel. Said contour = 4868 feet in the NGVD29 Datum. This data is provided for design purposes only — no structures or construction plans exist at this time. Signature / Date L� • f // 6/d -7 ❑ Check here if attachments SECTION E - BUILDING ELEVATION INFORMATION (SURVEY NOT REQUIRED) FOR ZONE AO AND ZONE A (WITHOUT BFE) For Zones AO and A (without BFE), complete Items E1 -E5. If the Certificate is intended to support a LOMA or LOMR -F request, complete Sections A, B, and C. For Items E1 -E4, use natural grade, if available. Check the measurement used. In Puerto Rico only, enter meters. E1. Provide elevation information for the following and check the appropriate boxes to show whether the elevation is above or below the highest adjacent grade (HAG) and the lowest adjacent grade (LAG). a) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. b) Top of bottom floor (including basement, crawl space, or enclosure) is ❑ feet ❑ meters ❑ above or ❑ below the LAG. E2. For Building Diagrams 6 -8 with permanent flood openings provided in Section A Items 8 and /or 9 (see page 8 of Instructions), the next higher floor (elevation C2.b in the diagrams) of the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E3. Attached garage (top of slab) is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E4. Top of platform of machinery and /or equipment servicing the building is ❑ feet ❑ meters ❑ above or ❑ below the HAG. E5. Zone AO only: If no flood depth number is available, is the top of the bottom floor elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown. The local official must certify this information in Section G. SECTION F - PROPERTY OWNER (OR OWNER'S REPRESENTATIVE) CERTIFICATION The property owner or owner's authorized representative who completes Sections A, B, and E for Zone A (without a FEMA- issued or community- issued BFE) or Zone AO must sign here. The statements in Sections A, 8, and E are correct to the best of my knowledge. Property Owner's or Owner's Authorized Representative's Name Address City State ZIP Code Signature Date Telephone Comments ❑ Check here if attachments SECTION G - COMMUNITY INFORMATION (OPTIONAL) The local official who is authorized by law or ordinance to administer the community's floodplain management ordinance can complete Sections A, B, C (or E), and G of this Elevation Certificate. Complete the applicable item(s) and sign below. Check the measurement used in Items G8. and G9. G1. ❑ The information in Section C was taken from other documentation that has been signed and sealed by a licensed surveyor, engineer, or architect who is authorized by law to certify elevation information. (Indicate the source and date of the elevation data in the Comments area below.) G2. ❑ A community official completed Section E for a building located in Zone A (without a FEMA- issued or community- issued BFE) or Zone A0. G3. ❑ The following information (Items G4. -G9.) is provided for community floodplain management purposes. G4. Permit Number I G5. Date Permit Issued I G6, Date Certificate Of Compliance /Occupancy Issued G7. This permit has been issued for: ❑ New Construction ❑ Substantial Improvement G8. Elevation of as -built lowest floor (including basement) of the building: _❑ feet ❑ meters (PR) Datum G9. BFE or (in Zone AO) depth of flooding at the building site: ❑ feet ❑ meters (PR) Datum Local Official's Name Title Community Name Telephone Signature Date Comments ❑ Check here if attachments FEMA Form 81 -31, February 2006 Replaces all previous editions MATERIALS ASTM D -6938 Density of Soil and PR PAGE #1 OF I INT DATE 411312008 TESTING & Soil-Aggregate in Place by Nuclear RADIOEASTERN J RAL0G11RPT035MD DOC2I IC -TETON INSPECTION Methods (Shallow Depth) o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #: N/A Project Manager: Troy Posio Inspector: Gary Billman Inspection Date: April 9, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location & Depth Wet Percent Dry Mat'l. % Pass/ # Density Moisture Density Type Comp. Fail 1 (10 ") — south parking lot, 1' below top of asphalt: 20' 131.0 4.1 125.8 1 100 Pass north, 67' west of southeast parking lot corner 2 (12 ") — 40' west, 15' north of southeast parking lot corner 126.5 3.8 121.8 1 96 Pass 3 (10 ") — 112' west, 25' north of southeast parking lot corner 131.5 4.7 125.6 1 99 Pass 4 (12 ") — 157' west, 20' north of southeast parking lot corner 133.4 4.2 128.0 1 100 Pass 5 (10 ") — 50' east, 15' south of northwest parking lot corner 134.5 4.1 129.2 1 100 Pass Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 126.5pcf @ 9.5% Zollinger pit -pit run (P2909) ASTM D -698 Gauge Information: MTI #: 40 Make &Model: T roxler3430 S erial #:'27576 Standard Counts:, DS: 1994 MS: 613 If there are questions concerning this report (rpt035md), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. s r4 i I M ! I OF RE . B!J ,G 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mWEDmti- id.com • Website: www.mti- id.com If there are questions concerning this report (rpt038md), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC, Janell Hansen, City of Rexburg Building Department. 1230 North, Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mtiC rnfl- id.com • Website: www.mti- id.com CPO IVMATERIALS ASTM D- 6938 Density of Soil and PPIN o #T 4 2612009 . TESTING & Soil- Aggregate in Place by Nuclear RAEASTERN R.o 0 O TME80C 1C -TETON INSPECTION Methods (Shallow Depth) ❑ Environmental Services ❑ Geotechnical Engineering ❑ Construction Materials Testing ❑ Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: '(208) 359 -6457 450 East Main Street other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #: 08- 00322 Project Manager: Troy Posio Inspector:. Gary Billman Inspection Date: April 22, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location & Depth Wet - Percent Dry Mat'l. % Pass/ # Density i Moisture Density Type Comp. Fail *All tests taken using Direct Transmission method at 4" 1 Sidewalk west side of building, top of 3 /4" base: 15' north 9 129.3 3:1 125.3 and 12' west of southwest building corner 1 97 Pass 2 35' south and 11' west of northwest building corner 126.2 3.0 122.5 1 95 Pass 3 25' south and 10' west of northwest building corner 127.0 3.5 122.7 1 95 Pass *All tests taken using Direct Transmission method at 6" Sidewalk north side of E. 4 th N, 10" below top of concrete: 4 7' south and 2' east of Stake 5021 128.5 5.0 122.3 2 97 Pass 5 10' east and 6' south of Stake 5017 136.0 6.2 128.0 2 100 Pass 6 12' west and 5' south of Stake 5014 127.5 6.5 119.8 2 95 Pass Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 129.2pcf @ 12.4% Ashcraft Pit - %" minus base aggregate (P2940) ASTM D -1557 2: 126.5pcf @ 9.5% Zollinger Pit - pit run (P2909) ASTM D -698 Gauge Information If there are questions concerning this report (rpt038md), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC, Janell Hansen, City of Rexburg Building Department. 1230 North, Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mtiC rnfl- id.com • Website: www.mti- id.com MATERIALS ASTM D -6938 Density of Soil and PRINT 1E *1111 DATE 412612009 TESTING & Soil- Aggregate in Place by Nuclear RAEAsTERN Ra - 0 008R E Po wu000 1c-TETON INSPECTION Methods (Shallow Depth) ❑ Environmental Services ❑ Geotechnical Engineering ❑ Construction Materials Testing ❑ Special Inspections Mark Harrelson Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #• N/A Project Manager: Troy Posio Inspector: Daniel Baugh Inspection Date: April 21, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location &Depth Wet Percent Dry Mat'I. % Pass/ # Density Moisture Density Type Comp. Fail *All tests taken using Backscatter method Bottom of curb, final grade: 17' south and 6' east of light 1 133.4 5.0 127.1 1 98 Pass pole on west side of parking lot 2 35' north of light pole on south side of west approach 130.0 6.4 122.2 1 95 Pass 30' north and 16' west of light pole on east side of west 3 132.4 5.8 125.2 1 97 Pass parking lot 32' west and 3' south of light pole at northeast corner of 4 132.0 5.2 125.5 1 97 Pass west parking lot 5 16' north and 30' west of light pole at northwest corner of 128.5 4.1 123.4 1 96 Pass south parking lot 53' north and 7' east of light pole at southeast corner of 6 131.2 5.6 124.3 1 96 Pass south parking lot 7 32' east and 53' north of light pole at southeast comer of 131.0 5.4 124.3 1 96 Pass south parking lot Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 129.2pcf @ 12.4% Depateo Ashraft Pit - V poorly graded gravel with silt/sand (P2940 -5) ASTM D- 1557 VQY V 1111V1111QI.1V11. MTI #: 14 Make &Model: Troxler 3430 Serial #: 26084 Standard Counts: DS: 2077 MS: 679 If there are questions concerning this report (rpt037md), please contact the project manager at (208) 529- 8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(cDmti- id.com • Website: www.mti- id.com D -3 Z, z- MATERIALS ASTM D -6938 Density of Soil and PRINT DATE 412212009 R kEASTERN lom ID TESTING & Soil- Aggregate in Place by Nuclear RADIOLZOGIIRPT036MDEDOC „C -TETON INSPECTION Methods (Shallow Depth) o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #: N/A Project Manager: Troy Posio Inspector: Gary Billman and Daniel Baugh Inspection Date: April 20, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location & Depth Wet Percent Dry Mat'l. % Pass/ # Density Moisture Density Type Comp. Fail *All tests taken using Backscatter method 1 Curb and gutter, top of 1 /4” minus base: 1' north, 80' west 132.6 3.7 127.9 1 of southeast parking lot corner 99 Pass 2 F north, 35' west of southeast parking lot corner 131.8 4.0 126.7 1 98 Pass Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 129.2pcf @ 12.4% Ashcraft pit - %" minus base aggregate (P2940) ASTM D -1557 Gaug, Information MY! # X40 Make &Model Troxler3430 Serial #: Standard Count's" DS i 2018 ' MS 554 If there are questions concerning this report (rpt036md), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mtiOrriti- id.com • Website: www.mti- id.com „' MATERIALS ASTM D -6938 Density of Soil and PRINT DA /2009 RIEASTERN cp TESTING & Soil- Aggregate in Place by Nuclear P ND1OLOG MDEDOC IIC-TETON INSPECTION Methods (Shallow Depth) o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #: N/A Project Manager: Troy Posio Inspector: Jared Russell Inspection Date: April 29, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location & Depth Wet Percent Dry Mat'1. % Pass/ # Density Moisture Density Type Comp. Fail *All tests taken using Direct Transmission method at 8” 1 Under sidewalk, finish grade: 12' south and 50' west of 133.1 5.2 126.5 1 100 Pass southwest building comer 2 20' south and 35' east of southeast building comer 132.2 8.2 122.1 1 96 Pass 3 90' south and 30' east of southeast building corner 132.7 4.8 126.6 1 100 Pass Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 126.5pcf @ 9.5% Zollinger Pit — pit run (P2909 -S) ASTM D -698 Gauge Information MTI #: 40 Make & Model: Troxler 3430 Serial #:27576 StandardCounts�DS: 2011 IMS 621 If there are questions concerning this report (rpt041 md), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building MAY - 6 2009 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(cDmti- id.com • Website: www.mti - id.com MATERIALS ASTM D -6938 Density of Soil and PR PAGE #1 OF 1 INT DATE 6 /112009 CP 0 R: \EASTERN TESTING & Soil- Aggregate in Place by Nuclear RADIOLOGARPT039MDEDOC -TETON INSPECTION Methods (Shallow Depth) o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #: N/A Project Manager: Troy Posio Inspector: Gary Billman Inspection Date: April 23, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location & Depth Wet Percent Dry Mat'l. % Pass/ # Density Moisture Density Type Comp. Fail *All tests taken using Backscatter method I South sidewalk on north side of E 4` N, top of 1/4" 130.0 4.3 124.7 1 97 Pass material: 6' south and 4' east of Stake #5013 2 5' south of Stake #5016 129.2 3.9 124.4 1 96 Pass 3 3' south of Stake #5018 127.4 3.6 123.1 1 95 Pass 6' west and 8' south of fire hydrant north of the corner of E 4 126.7 3.2 122.8 1 95 Pass 4` N and First American Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 129.2pcf @ 12.4% Ashcraft Pit -' /a" minus base aggregate (P2940) ASTM D -1557 Gauge Information: ,.. ........ __.. .... MTI # !40 I Make & Model Troxler 3430 Serial #. 27576 Standard Counts DS 2008 MS 612 If there are questions concerning this report (rpt039md), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. __ F61 4 — Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mtiCcDmti- id.com • Website: www.mti- id.com MATERIALS TESTING 6 INSPECTION PAGE #1 OF PRINT DATE 51112009 RAEASTERN lomo\2008REPORTME80211 C - TETON RADIOLOGIIRPT040SWE.DOC o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Project Manager: Troy Posio Inspector: Josh Clark Inspection Date: April 24, 2009 STRUCTURAL STEEL WELDING INSPECTION REPORT On the above date, our representative performed work on the referenced project as reported below. Arrived on site and visually inspected the completed welding performed by qualified welders using a FCAW process with E -71M electrodes. Inspection consisted of single pass fillet welds and complete joint penetration welds at W -beam splice. Performed ultrasonic testing; a total of two welds were tested with two rejectable indications located on row F line 6. Note: Failing indications found in top and bottom flanges. Only fillet welds can be inspected on reinforcing plates for web. MTI needs RFI for this connection. Work inspected was in compliance with project plans and specifications, except as noted. REINSPECTIONIRETESTING REQUIRED If there are questions concerning this report (rpt040swe), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mtiO)mti- id.com • Website: www.mti - id.com MATERIALS ASTM C -39 Concrete Cylinder PRINT 1A11 I DA#E OF 311612009 TESTING & Compressive Strength RADIOLZOG1 1C90658.Doc0211C -TETON INSPECTION ❑ Environmental Services ❑ Geotechnical Engineering ❑ Construction Materials Testing ❑ Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Project Manager: Troy Posio Permit #• N/A Contractor: Oakland Inspector: Gary Billman Supplier: Walters Ready Mix Truck #: 116 Ticket #: 09928 Mix ID: 172 # Of Yards: 21 of 32 Report #: 032rc Location: Floor slab between lines 6 -6.9 rows A -B MIX PROPORTIONS PROVIDED BY SUPPLIER: TEST PROPERTIES & CONDITIONS: Batch Size (cy): Cylinder Weather Conditions: Partly sunny, windy Cement (lbs): Compressive Ambient Temperature (F): 29 Fly Ash (lbs): Not Concrete Temp. (ASTM C 1064) (F): 69 Water (gal): Provided Time Concrete Batched (from Ticket): 7:06am Coarse Agg. #1 (lbs): By Time Representative Concrete Placed: 7:50am Coarse Agg. #2 (lbs): The Air Content (ASTM C 231 or C -173) ( %): 2.6 Fine Agg. #1 (lbs): Redi Slump (ASTM C 143) (inches): 6 Fine Agg. #2 (lbs): Mix Unit Weight (ASTM C 138): ---- - - - - -- Admix # 1 (oz): Company Yield (ASTM C 138): ---- - - - - -- Admix #2 (oz): Water Added (gals): 0 Admix #3 (oz): Set # (if any) ---- - - - - -- Water /Cement Ratio: 12 1.00 28.18 28 Sampled in accordance with ASTM C 172 Cylinders cast in accordance with ASTM C31 — Field / C 192 - Lab Cast pate: Mar 5, 09 Specified f'c(psi): 4000 # of Cylinders: 4 Cylinder Corr. Cylinder Test Test Failure Compressive C-617 Fracture ID Diam. Height Factor Area Age Date Load Strength Cap Type Compliance 90658 5.99 12 1.00 28.18 7 Mar 12, 09 110,595 3920 2 90659 5.99 12 1.00 28.18 28 90660 5.99 12 1.00 28.18 28 90661 5.99 12 1.00 1 28.18 1 H Notes: Cylinder diameter based on average for indicated test date; ASTM C -617 is a sulfur cap — ASTM C 1231 neoprene pads used unless otherwise noted. Note: Super plasticizer added to concrete onsite, polyheed997. If there are questions concerning this report (00658), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(cDmti- id.com • Website: www.mti- id.com MATERIALS ASTM C -39 Concrete Cylinder PRINT PAGE OF I DA A TE311212009 TESTING & Compressive Strength Roo OGY\C90650.Doc -TEfON INSPECTION o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Project Manager: Troy Posio Permit #• N/A Contractor: Oakland Inspector: Gary Billman Supplier: Walters Ready Mix Truck #: 95 Ticket #: 09909 Mix ID: 172 # Of Yards: 10 of 29 Report #: 030co Location: Floor slab lines 3 -4, rows C -17.2 MIX PROPORTIONS PROVIDED BY SUPPLIER: TEST PROPERTIES & CONDITIONS: Batch Size (cy): Cylinder Weather Conditions: Overcast Cement (lbs): Failure Ambient Temperature (F): 35 Fly Ash (lbs): Not Concrete Temp. (ASTM C 1064) (F): 66 Water (gal): Provided Time Concrete Batched (from Ticket): 7:02am Coarse Agg. 41 (lbs): By Time Representative Concrete Placed: 7:34am Coarse Agg. 42 (lbs): The Air Content (ASTM C 231 or C -173) ( %): 4.9 Fine Agg. 41 (lbs): Redi Slump (ASTM C 143) (inches): 5% Fine Agg. 42 (lbs): Mix Unit Weight (ASTM C 138): ---- - - - - -- Admix #1 (oz): Company Yield (ASTM C 138): ---- - - - - -- Admix #2 (oz): Water Added (gals): 0 Admix #3 (oz): 90651 Set # (if any) ---- - - - - -- Water /Cement Ratio: 1.00 28.27 28 Sampled in accordance with ASTM C 172 Cylinders cast in accordance with ASTM C31 — Field / C 192 - Lab Cast Date: Mar 4, 09 Specified fc (psi): 4000 # of Cylinders: 4 Cylinder Corr. Cylinder Test Test Failure Compressive C -617 Fracture ID Diam. Height Factor Area Age Date Load Strength Cap Type Compliance 90650 5.96 12 1.00 27.90 7 Mar 11, 09 126,700 4540 4 90651 6 12 1.00 28.27 28 90652 6 12 1.00 28.27 28 90653 6 12 1 1.00 28.27 1 H Notes: Cylinder diameter based on average for indicated test date; ASTM C -617 is a sulfur cap — ASTM C 1231 neoprene pads used unless otherwise noted. Note: Super Plasticizer placed in concrete onsite. If there are questions concerning this report (00650), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti _mti- id.com • Website: www.mti- id.com MATERIALS ASTM C -39 Concrete Cylinder R PRINT �� # RN 4/3/2009 PAGE OF I TESTING & Compressive Strength IRADioLochc90658.00c0211c -TeroN INSPECTION 'I o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Project Manager: Troy Posio Permit #• N/A Contractor: Oakland Inspector: Gary Billman Supplier: Walters Ready Mix Truck #: 116 Ticket #: 09928 Mix ID: 172 # Of Yards: 21 of 32 Report #: 032rc r Cast Date: Mar 5, 09 Specified fc (psi): 4000 # of Cylinders: 4 Cylinder TEST PROPERTIES & CONDITIONS: MIX PROPORTIONS PROVIDED BY SUPPLIER: Batch Size (cy): Test Weather Conditions: Partly sunny, windy Cement (lbs): C-617 Ambient Temperature (F): 29 Fly Ash (lbs): Not Concrete Temp. (ASTM C 1064) (F): 69 Water (gal): Provided Time Concrete Batched (from Ticket): 7:06am Coarse Agg. #1 (lbs): By Time Representative Concrete Placed: 7:50am Coarse Agg. #2 (lbs): The Air Content (ASTM C 231 or C -173) ( %): 2.6 Fine Agg. #1 (lbs): Redi Slump (ASTM C 143) (inches): 6 Fine Agg. #2 (lbs): Mix Unit Weight (ASTM C 138): ---- - - - - -- Admix #1 (oz): Company Yield (ASTM C 138): ---- - - - - -- Admix #2 (oz): Water Added (gals): 0 Admix #3 (oz): 12 Set # (if any) ---- - - - - -- Water /Cement Ratio: 28 Apr 2, 09 136,230 4830 Sampled in accordance with ASTM C 172 5 PASS Cylinders cast in accordance with ASTM C31 — Field / C 192 - Lab Cast Date: Mar 5, 09 Specified fc (psi): 4000 # of Cylinders: 4 Cylinder Corr. Cylinder Test Test Failure Compressive C-617 Fracture ID Diam. Height Factor Area Age Date Load Strength Cap Type Compliance 90658 5.99 12 1.00 28.18 7 Mar 12, 09 110,595 3920 2 90659 5.99 12 1.00 28.18 28 Apr 2, 09 136,230 4830 5 PASS 90660 5.99 12 1.00 28.18 28 Apr 2, 09 145,820 5170 4 PASS 90661 1 5.99 12 1 1.00 1 28.18 1 28 Apr 2, 09 1 137,180 1 4870 2 1 PASS Notes: Cylinder diameter based on average for mdmeatea test date; ns r M tr - It is a stumr cap —AD t rvi %_ iz.� r neoprouc paus uacu Note: Super plasticizer added to concrete onsite, polyheed997. If there are questions concerning this report (c90658), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC;Janell Hansen, City of Rexburg Building Department. JR I APR - 6 M9 CITY OF REXBUitG 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(d)mti- id.com • Website: www.mti id.com Co MATERIALS ASTM C -39 Concrete Cylinder PAGE #RN°32o09 TESTING & Compressive Strength R oOLOGAc90650. Do 1c -TETON INSPECTION o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Project Manager: Troy Posio Permit df• N/A Contractor: Oakland Inspector: Gary Billman Supplier: Walters Ready Mix Truck #: 95 Ticket #: 09909 Mix ID: 172 # Of Yards: 10 of 29 Report #: 030co Location: Floor slab lines 3 -4, rows C -F.2 Test MIX PROPORTIONS PROVIDED BY SUPPLIER: TEST PROPERTIES & CONDITIONS: Batch Size (cy): Weather Conditions: Overcast Cement (lbs): Ambient Temperature (F): 35 Fly Ash (lbs): Not Concrete Temp. (ASTM C 1064) (F): 66 Water (gal): Provided Time Concrete Batched (from Ticket): 7:02am Coarse Agg. 41 (lbs): By Time Representative Concrete Placed: 7:34am Coarse Agg. #2 (lbs): The Air Content (ASTM C 231 or C -173) ( %): 4.9 Fine Agg. #1 (lbs): Redi Slump (ASTM C 143) (inches): 5' /Z Fine Agg. #2 (lbs): Mix Unit Weight (ASTM C 138): ---- - - - - -- Admix #1 (oz): Company Yield (ASTM C 138): ---- - - - - -- Admix #2 (oz): Water Added (gals): 0 Admix #3 (oz): Set # (if any) ---- - - - - -- Water /Cement Ratio: 4 Sampled in accordance with ASTM C 172 90651 Cylinders cast in accordance with ASTM C31 — Field / C 192 - Lab Cast Date: Mar 4, 09 Specified f'c (psi): 4000 # of Cylinders: 4 Cylinder Corr. Cylinder I Test Test Failure Compressive C -617 Fracture ID I Diam. Height Factor Area A e Date Load Strength _Cap Type Compliance 90650 5.96 12 1.00 27.90 7 Mar 11, 09 126,700 4540 4 90651 5.96 12 1.00 27.90 28 Apr 1, 09 163,350 5860 4 PASS 90652 5.96 12 1.00 27.90 28 Apr 1, 09 160,320 5750 4 PASS 90653 5.97 12 1.00 27.99 28 Apr 1, 09 159,455 5700 4 PASS Notes: Cylinder diameter based on average for indicated test date; AS 1 M U -6111s a sulnu cap — As 1 M U its 1 neoprene pass useO umess Ou1el W15C 11ULUU. Note: Super Plasticizer placed in concrete onsite. If there are questions concerning this report (c90650), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(cDmti- id.com • Website: www.mti - id.com MATERIALS ASTM D -6938 Density of Soil and PR PAGE #1 OF 1 INT DATE 4l92009 R: \EASTERN RADI OL2O08REPOR 1VIDDO 211C -TETDN TESTING & Soil- Aggregate in Place by Nuclear 16 RADIOL0011RPT034MD. DOC INSPECTION Methods (Shallow Depth) o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #: N/A Project Manager: Troy Posio Inspector: Gary Billman Inspection Date: April 7, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location & Depth Wet Percent Dry Mat'l. % Pass/ # Density Moisture Density Type Comp. Fail 1 (6 ") — parking lot 1' below existing grade, 30' west, 30' 108.0 7.3 100.7 1 95 Pass south of southeast building corner 2 (8 ") — parking lot 1' below existing grade, 45' west, 40' 107.7 2.8 104.8 1 99 Pass south of southeast building corner 3 (8 ") — parking lot 2' below existing grade, 70' west, 65' 115.9 12.2 103.4 1 98 Pass south of southeast building corner 4 (8 ") — parking lot 2.5' below existing grade, 90' west, 80' 111.5 11.0 100.5 1 95 Pass south of southeast building corner Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 105.5pcf @ 15.1% onsite -sand (P2931) ASTM D -698 Gauge Information: NM #: 40 Make & Model: Troader 3430 Serial #: 27576 Standard Counts: DS: 2015 MS: 612 If there are questions concerning this report (rpt034md), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(cbmti- id.com • Website: www.mti - id.com MATERIALS TESTING £s INSPECTION PAGE #1 OF 1 PRINT DATE 4/9/2009 RA EASTERNIDAHO\2008REPORTS1E80211c- TETON RADIOLOGARPTWIDOC o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Project Manager: Troy Posio Inspector: Troy Posio Inspection Date: April 6, 2009 INSPECTION REPORT On the above date, our representative performed work on the referenced project as reported below. MTI inspector arrived onsite to perform density testing on the south parking lot. The parking lot has soft areas that need to be addressed prior to compaction and placing a pavement section. MTI recommends that the contractor follow one of the following: 1. Rip area and disc to allow aerating. This could be accomplished in a timely manner, weather permitting. 2. Over - excavate parking lot V or until sand is reached. In areas that sand is not noted, place fabric prior to bringing in structural fill. Compact all structural fill to 95% of ASTM D -698. 3. Armor ground by placing 3" clean select rock and rolling it into soft areas. Continue process until the 3" material will no longer be compacted into the soft areas. Contractor requested density testing performed in a couple locations that appeared to be dry and not soft. Readings were between 85 % -92 %. Inspector collected a sample to perform a proctor in accordance with ASTM D -698. If there are questions concerning this report (rpt033), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti @mti- id.com • Website: www.mti- id.com MATERIALS TESTING S INSPECTION 0800322 Teton Radiology Madison o Environmental Services o Geotechnical Engineering o Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Project Manager: Troy Posio Inspector: Josh Clark Inspection Date: May 15, 2009 STRUCTURAL STEEL WELDING INSPECTION REPORT On the above date, our representative performed work on the referenced project as reported below. Arrived on site and visually inspected the completed welding performed by qualified welders using a SMAW process with E -7018 electrodes. Inspection consisted of single pass fillet welds and complete joint penetration welds on w -beam to w -beam splice. Performed ultrasonic testing at multi - diagnostic room. A total of 2 welds were tested with one rejectable indication located at multi diagnostic room splice on beam. Note: Bottom flange of beam had failing indication; also web stiffeners in multi diagnostic room were welded down -hand, which is not acceptable per AWS D1.1. Also need clarification for type of bolts to use in structure. Work inspected was in compliance with project plans and specifications, except as noted. REINSPECTIONIRETESTING REQUIRED If there are questions concerning this report (rpt042swe), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. MAY 2 1 2009 CITY OF REXBURG 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(cbmtkid.com • Website: www.mb- id.com MATERIALS ASTM D -6938 Density of Soil and PR E NT DAA O 512212009 R: \EASTERN ID TESTING & Soil- Aggregate in Place by Nuclear RADIO \LOGY\RPT043MDEDOC11C -TETON INSPECTION Methods (Shallow Depth) o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #: N/A Project Manager: Troy Posio Inspector: Daniel Baugh Inspection Date: May 20, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location & Depth Wet Percent Dry Mat'1. % Pass/ # Density Moisture Density Type Comp. Fail *All tests taken using Direct Transmission method at 8" Center of storm trench in northwest entrance to west 1 parking lot at top of subgrade: 10' north of curb on south 126.0 3.1 122.2 1 97 Pass side of entrance 2 20' north of curb on south side of entrance 126.5 4.0 121.6 1 96 Pass *All tests taken using Backscatter method 3 Center of sidewalk on west side of building at top of sub- 128.6 2.9 125.0 2 97 Pass base: 45' north and 9' west of southwest building corner 4 50' northwest of road 126.8 2.3 123.9 2 96 Pass Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 126.5pcf @ 9.5% Zollinger Pit — pit run, poorly graded sand with gravel (P2909) ASTM D -698 2: 129.2pcf @ 12.4% Depatco Pit - %" poorly graded gravel with silt and sand (P2940)ASTM D -1557 Gauge Information MTI# '41 Make & Modell: Tro�der3430. Serial # 127576 Standard Counts:' DS: 2360 CMS 661 .............. _ _._.... .. If there are questions concerning this report (rpt043md), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(o)mtkid.com • Website: www.mti - id.com MATERIALS ASTM D -6938 Density of Soil and PR PAGE #1 OF 1 INT DATE 6 /1/2009 R: \EASTERN CP TESTING & Soil- Aggregate in Place by Nuclear RADIOLZOGY \RPT044MD.DOCI1C -TETON INSPECTION Methods (Shallow Depth) o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #: N/A Project Manager: Troy Posio Inspector: Josh Clark Inspection Date: May 28, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location & Depth Wet Percent Dry Mat'l. % Pass/ # Density Moisture Density Type Comp. Fail *All tests taken using Direct Transmission method at 12" 1 South parking lot, 7" below top of asphalt: 70' west and 139.5 5.4 132.3 1 100 Pass 15' north of southeast corner 2 25' west and 35' north of southeast corner 126.5 5.1 120.3 1 95 Pass 3 50' east and 85' north of southeast corner 136.6 5.4 129.7 1 100 Pass 4 40' east and 12' south of northwest corner 135.1 4.8 128.8 1 100 Pass 5 30' west and 25' south of northwest corner 140.0 5.0 133.4 1 100 Pass 6 50' east and 25' north of northwest corner 136.8 3.7 132.0 1 100 Pass 7 30' north and 25' west of southwest building corner 134.9 3.9 129.8 1 100 Pass 8 50' west and 10' south of northeast corner of north most 135.7 4.8 129.5 1 100 Pass parking lot 9 10' east and 35' south of northeast corner 136.7 4.3 131.1 1 100 Pass 10 West parking lot, 7" below top of asphalt: 10' east and 10' 135.3 3.1 131.2 1 100 Pass south of northwest corner 11 12' north and 10' west of southeast corner 138.7 5.6 131.3 1 100 Pass Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 126.5pcf @ 9.5% Zollinger Pit - pit run (P2909) ASTM D -698 Gauge Information. MTI # ,17 Make & Model: Troxler 34401 Serial # 34596 Standard Counts: DS:. 2547 MS 736 If there are questions concerning this report (rpt044md), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(ccilmti- id.com • Website: www.mti - id.com 0s, f MATERIALS TESTING S INSPECTION PAGE #1 OF 1 PRINT DATE 6/1/2009 R: \EASTERN IDAHO\2008REPORTS\E80211C- TETO1i RADIOLOGY\RPT045SWE. DOC o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Project Manager: Troy Posio Inspector: Josh Clark Inspection Date: May 28, 2009 STRUCTURAL STEEL WELDING INSPECTION REPORT On the above date, our representative performed work on the referenced project as reported below. Arrived on site and visually inspected the completed welding performed by qualified welders using a SMAW process with E -7018 electrodes. Inspection consisted of single pass fillet welds and complete joint penetration welds. Performed ultrasonic testing; a total of one weld was tested with no rejectable indications. Retests passed. Work inspected was in compliance with project plans and specifications. If there are questions concerning this report (rpt045swe), please contact the project manager at (208) 529 -8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. 0 4 — Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(a)mti- id.com • Website: www.mti - id.com MATERIALS ASTM D -2950 Density of Bituminous PRNT °52009 RNEASTERN TESTING & Concrete in Place by Nuclear Methods DAHOM08REPORTME80211c -TETON INSPECTION C P RADIOLOGI1RPT047AD. DOC o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 , " " 3z Z ProjectCeton Radiology, Rexburg Permit # Project Manager:, Troy Posio Inspector: ; Josh Clark Inspection Date:' June 3, 2009 Contractor Name: Okland Weather: Partly cloudy Gauge #: 17 DS: 2542 Material Source: Teton Pit Marshall Unit Weight: Mix Temperature (Delivered): 280 -295 °F Paving Contractor: HK MS: 738 % Comp. Spec. 92 -95% Asphalt Mix Description: '' /z" Commercial Hveem Maximum Theoretical: 143.4 Mix Design Provided: Yes X No Spec. Mat Thick. 3" Test # Location Test A Test B Average Core Corrected Percent Core I South parking lot: 60' west and 25' north of southeast 131.4 9o 132.3, 131.9 Correlation Density Comp. Thickness corner 2 60' north and 40' west of southeast corner 132.0 131.9 132.0 3 35' north and 30' east of southeast corner 131.9 132.7 132.3 4 50' north and 3' west of centerline of southeast 133.2 132.9 133.1 entrance 5 30' west and 25' south of southeast building corner 13 1 .4 13 2.4 131.9 6 35' north and 25' west of southwest building corner 133.4 131.7 132.6 7 West parking lot: 15' north and 15' east of southwest 134.2 132.7 133.5 corner 8 35' east and 5' south of centerline of northwest access 131.9 131'.2' 131.6 9 South parking lot: 50' east and 30' south of northwest 135.2 13- 134.4 ;< 10 r 30' west and 55' south of southwest building corner 131.3 131`. 131.4 11 corner 50' north and 10' east of centerline of southwest 130.1 129.2 129.7 entrance Gauge Information: MTI #: 17 Make & Model: Troxler 3440 Serial #: 34596 Standard Counts: DS: 2542 MS: 738 Note: No percent compaction given at this time since no cores were taken for correlation. Results shown are for information only. If there are questions concerning this report (rpt047ad.doc), please contact the project manager at (208) 529 -8242. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(ccilmti- id.com • Website: www.mti- id.com MATERIALS ASTM D -2950 Density of Bituminous PRINT DATE 662009 RIEASTERN TESTING & Concrete in Place by Nuclear Methods DAH2008REPORTM - TETON INSPECTION RADIOLOGI1RPT047AD. DOC o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. �/ - -+ Reviewed by: George DuPont Corporate Construction Services Manager' 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(Wmti- id.com • Website: www.mti - id.com o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Mark Harrison Phone: (208) 356 -3691 MMM Facilities, LLC Fax: (208) 359 -6457 450 East Main Street Other: Rexburg, ID 83440 Project: Teton Radiology, Rexburg Permit #: N/A Project Manager: Troy Posio Inspector: Josh Clark and Corey Wheeler Inspection Date: June 1, 2009 As requested, MTI performed density testing in accordance with current applicable standards. Required compaction is 95 %. The results obtained are as follows: Test Location & Depth Wet Percent Dry Mat'l. % Density Moisture Density Type Comp. Pass/ Fail 1 97 All tests taken using Backscatter method 1 98 Pass 1 95 I At finish ' / 4 " base: 3' north of southeast parking lot corner 128.6 2.4 125.5 2 20' east and 35' north of southeast parking lot corner 130.4 2.7 127.0 3 20' west and 10' north of southeast parking lot corner 126.0 2.5 122.9 4 65' west and 45' north of southeast parking lot corner 129.0 2.1 126.3 5 50' east and 12' south of northwest parking lot corner 126.7 3.0 123.0 6 30' west and 30' south of northwest parking lot corner 127.7 2.8 124.0 7 40' north of southwest entrance corner 132.9 3.8 128.1 8 20' north and 20' west of northwest parking lot corner 132.9 2.6 129.9 9 15' east and 5' north of northwest parking lot corner 128.0 ` 2.5 124.9 10 15' west and 40' south of northwest building corner 129.5 2.7 126.1 11 30' east of northwest access 129.5 2.7 126.1 12 6' east and 9' north of west parking lot corner 129.2 3.3 125.0 13 10' north of west parking lot southeast corner 126.6 2.4 123.6 14 20' south and 15' west of southeast building corner 127.4 2.1 124.7 15 25' south and 10' east of southeast building comer 128.6 1.9 126.3 16 50' northeast of southeast entrance 129.3 2.2 126.5 Method of testing: BS is Backscatter; Depth in inches is Direct Transmission Material Type: 1: 129.2pcf @ 12.4% DePatco Pit -'/4" minus base aggregate (P2940) Pass/ Fail 1 97 Pass 1 98 Pass 1 95 Pass 1 98 Pass 1 95 Pass 1 96 Pass 1 99 Pass 1 100 Pass 1 97 Pass 1 98 Pass 1 99 Pass 1 97 Pass 1 96 Pass 1 97 Pass 1 98 Pass 1 98 Pass ASTM D -1557 Gauge Information: MTI #: 33 Make & Model: Troxler 3411 Serial #: 7090 Standard Counts: DS: 143.6 MS: 532 If there are questions concerning this report (rpt046md.doc), please contact the project manager at (208) 529 -8242. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti@M i-id coin • Website: w8 mti- id.com MATERIALS ASTM D -6938 Density of Soil and PRINTDAA E O 6/4/ 009 R: \EASTERN TESTING & Soil- Aggregate in Place by Nuclear IDAHO RADIOLOGY\RPT046MDEDOC -TETON INSPECTION Methods (Shallow Depth) o Environmental Services o Geotechnical Engineering o Construction Materials Testing o Special Inspections Respectfully submitted, MATERIALS TESTING & INSPECTION, INC. Reviewed by: George DuPont Corporate Construction Services Manager cc: Mark Harrison, MMM Facilities, LLC; Janell Hansen, City of Rexburg Building Department. 1230 North Skyline Drive, Suite C, Idaho Falls, ID 83402 208 529 -8242 Fax: 208 529 -6911 Email: mti(cDmti- id.com • Website: www.mti- id.com 3L2 0800 r. .� �09 wo&nal DESIGN CALCULATIONS FOR REXBURG OUTPATIENT CLINIC Job # 07590 Client: Ward Blake Architects Jackson, Wyoming Designed by: Dean M. Tracy, PE TA BLE OF CONTENTS PAGE DESCRIPTION 1.0 Design Criteria Summary 2.0 -2.10 Roof Framing 3.0 -3.4 First Floor Framing 4.0 -4.7 Lateral Analysis 5.0 -5.10 Frame Design 6.0 -6.4 Header Design 7.0 -7.6 Column Design 8.0 -8.12 Foundation Design r . END JUL 7 M OF REXBURG f G & S Structural Engineers 1600 John Adams Parkway Suite 200 Idaho Falls, ID 83401 Telephone: (208) 523 -6918 E -mail: gs @gsengineers.net Fax: (208) 523-6922 6. C Tele- onea ) 523 -6918 E- mail:asagsenainests.net Design Criteria Summary for the Rexburg Outpatient Clinic Ground snow load - 47 psf Snow exposure factor Ce - 1 Thermal Factor Ct- 1 Snow load Importance I - 1 Roof snow load - 35 psf Roof dead load - 20 psf Floor live load - 100 psf Floor dead load - 20 psf Basic Wind Speed (3- second gust) - 90 mph Wind Importance Factor - 1 Wind Exposure - C Seismic Design Criteria Seismic Importance Factor - 1.0 Response Modification Coefficient R - 6.5 Spectral Response Accelerations Ss- 60.6 Si- 19.3 Site Class - Spectral Response Coefficients Sds - Sd 1 - Seismic Design Category - Seismic Response Coefficient Cs Snow Load Used in Seismic Calci G & S Structural Engineers 1600 John Adams Parkway Suite 200 Idaho Falls, ID 83401 C 0.468 0.207 D - 0.072 ilations - 20% x 35 psf = 27 psf Allowable Soil Bearing Pressure - 3000 psf Lateral Soil Load - 42 psf j'0 ,7 . f'/ 6&3 'C'E"nigirleers, Sheet -),o - Y 9 1/2" TJI® 210, 2 plies @ 16" o/c TJ -6e 6; S r sl J r be 5, User z,, PNI THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED i.'rr ?;let S,_r }; =..•12 Ri_'o` D1cJ�ell�ll r 7 t. Product Diagram 19 Co('ce; - Delectioe C-i:era STAND RD(LL L 360 TL:G240) - Brac.ng(Lu;. ?.f compress!o 1 edges Cep and bottom) must be braced at 3' to' etc un ess detailed cthenvise. Proper attachment and positioning of lateral brae ir9 iti fete sired o achue':e member slability Design assumes adequate continuous lateral support of the compression edge ADDITIONAL NOTES: - IMPORTANT' The analysis presented is output from software developed by iLevel !Levek� warrants tie sizing of its products by this software will be accomplished in acre c a te:e tlith Leveiib product design criteria and code accepted design values The soacific product application . input design loads . and stebed dimensions have been provided by the software user This output has not been reviewed by an iLevel Associate. -Not all products are readily avatlatie Check with your supplier or Level-9 technical representative fcr product availability -THIS ANALYSIS FOR :LeveiO PRODUCTS ONLY' PRODUCT SUBSTI - UT ON VO'DS THIS ANALYSIS - Allonab!e Stress Desigr methodology was used for Building Code UBC analyzing the iLevek? Distribution product listed above. -Note. See iLevelu Specifier s,'Buiider's Guide for multiple ply connection PROJECT INFORMATION: Rexburg Outpatient Clinic OPERATOR INFOR MATION: Dean Tracy G&S Structural Engineers !600 John Adams Parkway Suite 200 Idaho Falls. iD 83401 °hone . (2C8) 522 -5918 Fax :(2)81523 -6922 gsiagsengineers. net , All din are 1)Orizontal, LOADS: Analysis is for a Joist Member Primary Lcad Group - Snow (psf). 35.0 Live at 115 duration. 200 Dead SUPPORTS: Input Bearing Vertical Reactions (Ibs) Detail Other Width Length Live /DeadlUplik/Total 1 Stud wail 350' 3.50" 490 280 107770 F! Blocking 1 Ply 91i2'TJIz _ Stud wall 3.30• 3 50' 490 ; 280 1 0 ; 770 RI Blocking 1 Ply 9 1 ;2" 20 See iLeve:'D Specifier`s:Bu!laer's Guide for detad(s). R1 Blocking DESIGN CONTROLS: Maximum Design Control Result Location Shear (Ibs, 755 -749 3059 Passed (24'10) Rt. end Span 1 under Snow loading Vertical Reaction Nips 755 '55 3059 Passed (25 "%) 3eanng 2 under Snow loading Mortert (Ft -Lbs) 3884 3884 6578 Passed (59%) MID Span I under Snow loading Live t oac Dell (it), 0.592 D 686 Passed (L'417) MID Spar I under Snow loading Total Load Cefl l,ni 0.930 1.029 Passed (U265) MID Spar t under Snow loadirg Product Diagram 19 Co('ce; - Delectioe C-i:era STAND RD(LL L 360 TL:G240) - Brac.ng(Lu;. ?.f compress!o 1 edges Cep and bottom) must be braced at 3' to' etc un ess detailed cthenvise. Proper attachment and positioning of lateral brae ir9 iti fete sired o achue':e member slability Design assumes adequate continuous lateral support of the compression edge ADDITIONAL NOTES: - IMPORTANT' The analysis presented is output from software developed by iLevel !Levek� warrants tie sizing of its products by this software will be accomplished in acre c a te:e tlith Leveiib product design criteria and code accepted design values The soacific product application . input design loads . and stebed dimensions have been provided by the software user This output has not been reviewed by an iLevel Associate. -Not all products are readily avatlatie Check with your supplier or Level-9 technical representative fcr product availability -THIS ANALYSIS FOR :LeveiO PRODUCTS ONLY' PRODUCT SUBSTI - UT ON VO'DS THIS ANALYSIS - Allonab!e Stress Desigr methodology was used for Building Code UBC analyzing the iLevek? Distribution product listed above. -Note. See iLevelu Specifier s,'Buiider's Guide for multiple ply connection PROJECT INFORMATION: Rexburg Outpatient Clinic OPERATOR INFOR MATION: Dean Tracy G&S Structural Engineers !600 John Adams Parkway Suite 200 Idaho Falls. iD 83401 °hone . (2C8) 522 -5918 Fax :(2)81523 -6922 gsiagsengineers. net pAr ' 9 112" TJIO 210 @ 16" OIC TJ -B m s) 1N r - br , 513377° THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS e FOR THE APPLICATION AND LOADS LISTED zr;l;�er Sla:e: r' P.ijof SfoGeu E M : a Product Diagram is C0l71cel.tual- j - Detlectice Cntena STAND,',RD(LL. I-360 T_ L7240). -Erac ng(Lu) ,` -:I compression edges (top and bottom must be braced nr ., a,c unless detailed e, -. ^rue. Proper attachmec� and positroninc of lateral bracing is required to n member stability - Design assumes adequate , .ontinuou=_ lateral support of the compression edge ADDITIONAL NOTES: - IMPORTANT! The analysis presented is output from software developed by i-eveig iLevelCkr warrants the sizing of its products by this software will be accomplished in accorearce with Level CO oroduct design criteria and code acceptec design valies The specific produce application. :nput design loads, and stated dimensions have been provided by the software user This output has not been reviewed by an iLevelrD Associate. -Not ai preduc are readily ava lable, Check with your supplier or Lever technical representative for product availability -THIS ANALYSIS FOR iLevel'J PRCDUCTS CNLYI PRODUCT SUBSTITUTION VOIDS TH S ANALYSIS. - Allowable Stress Design methodo.agy was used for Building Code UBC analyzing the iLevel Distribution product listed above PROJECT INFORMATION: Rexburg Outpatient Cliric OPERATOR INFO RMATION: Dean Tracy G &S Structural Engineers 1600 John Adams Parkway Suite 200 Idaho Falls, ID 8340" Phone (208) 523 -6918 Fax (206) 523 -6922 gs,,_%)gsengireers -net All .Jfrrfertisioris are ;ior zontdl. LOADS: Analysis is `c( a Joist Member Primary Load Group - Sncw Ipsf) 35 Live at 115 duration, 20.0 Dead SUPPORTS: Input Bearing Vertical Reactions (Ibs) Detail Other Width Length Live /Dead(UplifU'Total ' Stud Na 1 3 SO" t.50" 3731 213 ? 0 58' RI Btockmg 1 Ply 9 112' TiLD 210 2 Stud wall 350" 3.50" 373i 21310' S8'. R1. Blocking I Fly9 112" tJh?7210 See ILeve6ii) Speclhei'srBufoer's Guide for detaJ(s): R1 Blocking DESIGN CONTROLS: Maximum Design Control Result Location Shear (Ibs; -565 1530 Passed (375b) Rt_ and Span 1 under Snow loading Yeibcai Reaction (Ibs) 57 571 1530 Passed (37`4.) Bearing 2 uncor Snow leading Mcmert (Ft -'_bs; _225 2226 3289 Passed (68i MID Span 1 under Snow loading Live Load Defl ;in, 0 403 0.519 Passed (L1464) MID Span I under Snow loading Total -, Deft fin) 0 633 0.779 Passed (L296) MID Span 1 under Snow loading Product Diagram is C0l71cel.tual- j - Detlectice Cntena STAND,',RD(LL. I-360 T_ L7240). -Erac ng(Lu) ,` -:I compression edges (top and bottom must be braced nr ., a,c unless detailed e, -. ^rue. Proper attachmec� and positroninc of lateral bracing is required to n member stability - Design assumes adequate , .ontinuou=_ lateral support of the compression edge ADDITIONAL NOTES: - IMPORTANT! The analysis presented is output from software developed by i-eveig iLevelCkr warrants the sizing of its products by this software will be accomplished in accorearce with Level CO oroduct design criteria and code acceptec design valies The specific produce application. :nput design loads, and stated dimensions have been provided by the software user This output has not been reviewed by an iLevelrD Associate. -Not ai preduc are readily ava lable, Check with your supplier or Lever technical representative for product availability -THIS ANALYSIS FOR iLevel'J PRCDUCTS CNLYI PRODUCT SUBSTITUTION VOIDS TH S ANALYSIS. - Allowable Stress Design methodo.agy was used for Building Code UBC analyzing the iLevel Distribution product listed above PROJECT INFORMATION: Rexburg Outpatient Cliric OPERATOR INFO RMATION: Dean Tracy G &S Structural Engineers 1600 John Adams Parkway Suite 200 Idaho Falls, ID 8340" Phone (208) 523 -6918 Fax (206) 523 -6922 gs,,_%)gsengireers -net 4 Project — Date Project No, 77 Designed By V [- If 5 ,7 / -/,, (, 0 vp k e , el� /0 � - 7, -,- Y 1 z ;, 10 3 Al Al I to <- q X1, -7 , — 1 G&S Structural Engineers Uhf x Sheet 4 Wood I OAnS ( lbs. ost, or plf) : I ICOMPANY I PROJECT Works q r - ks , I May 6,2008'4,38 woodlols, Design Check Calculation Sheet Sizer 7.0 ------- -------- 7­11" - 4 - I - - - --, ­r-, ­�!! �a­ �na er 1 7 . T, _-, - i - I I 1% -:] i .1 MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) : T-7,3 7'.7-3 7-6" 'Min bearing length for joists is 1/2" for exterior supports Lumber-soft, D.Fir-L, No.1, 2x10" Soacea at 12" c!c, Slope 10.0 deg, Total length 15-278", Self-weight of 3.3 plf included in loads: Lateral support: top= full, bottom= at supports: Repetitive factor applied where permitted (refer to online help). Analvsis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005: 1, q COMPANY I PROJECT WoodWorks" May 6 2008 15:27 woodjoist Design Check Calculation Sheet Sizer 7.0 1 OA lbs, psf, or plf A - MAXIMUM REA CTIONS (Ibs) and BEARING LENGTHS (in) : - _I ir 21 L J c a Z 4 A - MAXIMUM REA CTIONS (Ibs) and BEARING LENGTHS (in) : - _I ir 21 L L Lumber-soft, D.Fir-L, No.2, 3x12" Spacec at 24" c!c, Self-weight of 6 68 pif included in loads. Lateral support top= fill bottom= at supports, Oblique angle 5.0 [deg]: Repetitive factor applied where permitted (refer to owne heipj, [WARNING M --cer length exceeds typical stock length of 18,0 [ft] I Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005: F'x � � _ . - 'i = ��: L = - � = y i t - z' 5' ICOMPANY PROJECT J- WoodWorks' ilay 6 21208 15.216 _wcodjoist Design Check Calculation Sheet Sizer 7.0 1 OAns lbs, psf, or plf MAXIMUM REACTIONS (lbs) and BEARING LENGTHS (in) : 16i Lumber-soft, D.Fir-L, No.2, 3x12" Spaced at 24'* C/C ' Self-weight of 6,68 olf included in loads, Lateral support too= full bottom= at supports; Oblique angle 5 0 [deg]: Repetitive factor applied where permitted (refer to online nelp). This section FAILS the design check WARNING: Tnis section violates the following design criteria: Deflection Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005: v S S a 2 e S 2 1 P S r i MAXIMUM REACTIONS (lbs) and BEARING LENGTHS (in) : 16i -.7 / �/ 6 Lumber-soft, D.Fir-L, No.2, 3x12" Spaced at 24'* C/C ' Self-weight of 6,68 olf included in loads, Lateral support too= full bottom= at supports; Oblique angle 5 0 [deg]: Repetitive factor applied where permitted (refer to online nelp). This section FAILS the design check WARNING: Tnis section violates the following design criteria: Deflection Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005: v S S a 2 e S 2 1 r i ADDITIONAL DATA: 1,3a L n 1 a in C - _- E DESIGN NOTES: 1 Please verify that the default deflection limits are appropriate for your application 2 Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1 -.7 / �/ 6 Lumber-soft, D.Fir-L, No.2, 2x12" Spaced at 24" c/c ' Seff-weight of 4 0 1 p f included in loads. Lateral support: too= full bottom= at supports: Oblique angle. 5 0 [deg] Repetitive factor. applied where permitted (refer to online help) This section FAILS the design check WARNING: This section violates the following design criteria: Bonding and deflection WARNING: Member length exceeds typical stock length of 18.0 [ft] 7 COMPANY PROJECT WoodWorks" i May C 2008 15 301 woccloist ----------- Design Check Calculation Sheet Sizer 7.0 1 LOADS lbs, psf, or plf a 17 -1 rMAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) : 10' F 16' 2 - 1 Lumber-soft, D.Fir-L, No.2, 2x12" Spaced at 24" c/c ' Seff-weight of 4 0 1 p f included in loads. Lateral support: too= full bottom= at supports: Oblique angle. 5 0 [deg] Repetitive factor. applied where permitted (refer to online help) This section FAILS the design check WARNING: This section violates the following design criteria: Bonding and deflection WARNING: Member length exceeds typical stock length of 18.0 [ft] 7 DESIGN NOTES: 1. Please ver fy that the default deflecton limits are appropriate for your application 2. Continuous or Cantilevered Beams NDS Clause 4.2 5 5 requires that normal grading provisions be extended to he middle 2/3 of 2 spa, beams and to the full length of cantilevers and other spans 3. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4 41 . 4 The critical deflect on value has been determined using maximum back -span deflection. Cantilever deflections do not govern design n T Ui WoodWorks" u_ COMPANY PROJECT May 6. 2008 16 25 /voodjcis*, Design Check Calculation Sheet Sizer ?.0 LOADS ( Ibs, psf, or plf ) MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) : - I 10' 16' 21' "Min bearing length for joists is 1/2" for exterior supports and 1/2" for intermediate supports Lumber -soft, D.Fir -L, No.2, 2x12" Spaced at 12" ctc' Self- weight of 4.01 plf included in loads Lateral support top = ull. bottom= at supports Oblique angle 5 0 [deg], Repetitive factor applied where permitted (refer to online help) – - - - -- I – — This section FAILS the design check WARNING: This section violates the following design criteria: Deflection WARNING Member length exceeds typical stock length of t B.0 [ft] Analys vs. Allowable I St ress (psi) and Deflection (in) using NDS 2005: _ _ c 2:i DESIGN NOTES: 1. Please verify that the default deflection limits are appropriate for your application 2 Continucus or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2,13 of 2 spar; beams and to the full length of cantilevers and other spans. 3 Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1 4 The critical deflection value has been determined using maximum back -span deflection. Cantilever deflections do not govern design Project No. Date Project x /� � .,/? -t,7- w Designed By —fin 7 - T( 3 Sheet ?1 G&S Structural Engineers 117/8" TJl® 360 @ 16" o/c TJ- Beal 30 Semi IN cer ig05t0375 ezr 2 5- 3;_dzaB,�ati, THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS p En "' °.'v >rsidr G30 1d FOR THE APPLICATION AND LOADS LISTED Overall Cimenslom 46' 6" 15' t 16' 61, Prodt.:ct Diagram is Corcel,Wal. LOADS: Maximum Analysis Is for a Joist Member Result Location Shear (Ibs) 1584 1403 Primary Load Group - Office Slogs - Lobbies (psf) 1CO 0 Live a: 100 % duration, 20 0 Cead SUPPORTS: 3000 Passed (100 %1 Bearing 3 under Floor ADJACENT span loading Moment ,Ft -Lbs) .4567 -4567 6130 Input Bearing Vertical Reactions (Ibs) Detail Other Passed (L'522) Width Length LiveiDead /Uplift/Total 0 815 Passer: (L4531 Stud wall 3 50 c 2_ 925 ' 164 r 0 r 1090 A3 Rim Board t Ply 1 14" x '. 7, 8" C BE TJ Strand Rim Boardca' 2 Stud wall 5.50' 5 51 2385 t 428 r 0 It 2813 B3 None 3 Stud wall 5 -50' 5.59" ^2523; 467 r 0 2990 B3 None 4 Stud wail 3.50' 225" 992 r 181 10 ' 1173 A3' Rim Board 1 Ply 1 1r4" x 1' 7!8" 0.8E T„- Strand Rim Board � - CAUTION Required bearirg lengths) exceed the minimum shown in the iLevel(b Builder's eude for single family residential applications. Limits. End supports, 3 1,2" Intermediate supports, 3 112" with web stiffeners and 5 174' without we'o stiffeners. -See iLevelp Specifiers /Builcer's Guide for detail(s)'. A.3 Rim Boarc.B3 DESIGN CONTROLS: Maximum Design Control Result Location Shear (Ibs) 1584 1403 1705 Passed (82 %) Lt end Span 3 under Floor ADJACENT span loading Vertical Reaction {Ibs; 2990 2990 3000 Passed (100 %1 Bearing 3 under Floor ADJACENT span loading Moment ,Ft -Lbs) .4567 -4567 6130 Passed (74 Bearing 3 under F cor ADJACENT span loading Live Load Cefl (in) 0.375 0 407 Passed (L'522) MID Span 3 under Flccr ALTERNATE span loading 'Total Load De`:I onl 0.431 0 815 Passer: (L4531 MID Span 3 under Floor AL ERNATE span loading TJPro 47 30 Passed Span 3 - Cefiection Criteria. S7ANDARD(_LU480 TL 1(240). - Ceflechon analysis is based on composite action with single layer of 19/32" Panes (20" Span Rating) G_UED & NA LED wood decking. - Bracing(Lu). Ail compression edges l:op and bottom) must be braced at 3' 1C" c/o unless detailed c :herwise. Proper attachment and positioning of lateral Gracing is required to achieve member stability. -2000 Its concentrated coo recuirements for standard non- residential floors have been considered for reaction and shear -The lead conditions considered in this design analysis include a'.ternate and acjacert member pattern loading TJ - Pro RATING SYSTEM -The TJ -Pro Rating System value provides additional floor performance information and is basec on a GLJED & NAILED 19732" Panels (20" Span Rating) decking Tne controlling scar is supported by walls Additional considerations for this rating include. Ceiling - None A structural analysis of the deck has not been performed by the program Comparison Value ADDITIONAL NOTES: - IMPORTANT/ The analysis preserved is output front software developed by iLevel iLeveiT warrants the sizing of its products by this software will be accomplished in accordance with ii product desicn criteria and code accepted design values The specific product application.. input design loads, and stated dimensions nave been provided by to software user This output has not been reviewed oy an ii Associate. -Not all products are readily avaiable. Check with your supplier or iLevel(;` technical representative for product availability. -THIS ANALYSIS FOR iLevela PR -DUCTS ONLY' PRODUCT SUBSTITUTION VO DS THIS ANALYSIS. - Allowable Stress Design methodology was used for Building Code UBC analyzing the iLevel(Ii) Distribution product listed above. PROJECT INFORMATION: Rexburg Outpatient Clinic OPERATOR INFORMATION: Cean Tracy G &S Structural Engineers 1500 John Adams Parkway Suite 2 200 Idaho Falls, ID 83401 Phone .(20B)523 -6918 Fax (208) `_23 -6922 gsggsercineers. net n �r� A i 11 7/8" TJI® 210 @ 12" o/c N roe r ;' f` 8 482 C 'Jl THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS ` "'' 1 FOR THE APPLICATION AND LOADS LISTED Overall Gimat »h' -a" Pr.rra+_,ct Di <;ram i; Conceotual. LOADS: Analysis is for a Joist Membe Primary Load Grcup - Office Blegs - Lobbies (psf). 100 u Live at 100 ?� duratior, 20.0 Cead SUPPORTS: Input Bearing Vertical Reactions (Ibs) Result Width Length Live /Dead/Uplift/Total I Stud wall 3.50" 2 25" 694 i '.23 f 0 1 817 _ Stud wall 5.50" 5 50" 1789 / 321 r 01 2110 3 Stud wall 5.50" 5 Sc" 1892 / 350 i 0 / 2242 Stud wall 3 50 2 2 °' 744 ' 1 I 0 / 879 Detail Other A3. Rim Board I Ply 1 114" x 11 7'8" 0 8E TJ- Strand Rim BoardCO 63 None B3 None A3'. Rim Board 1 Ply 1 1/4" x 11 T8" 0.8E TJ- Strand Rim BoardC - CAUTION Reguned beanng length(sI exceed the minimum shown in the iLecelO Builder's guide to( single family residential applications Lmrts. End suppartc, 2 1' 2 e supports 3 V< Hdh weo stffeners and 5 1/4" without web stiffeners. -See iLevel : Specifier'& Elul cers C;u;de fo; detail(s) A3 Rim ooaid.63 DESIGN CONTROLS: Maximum Design Control Result Location Shear lfbs) 1'8S 1077 1655 Passed (65'0} Lt_ end Span 3 under Floor ADJACENT span loading Vertical Reaction { cs) 995 995 1110 Passed (9U`to) Bearing 4 under Concentrated loading Moment iFt -Lbs) -2425 -3425 3620 Passed (95 %,j Bearing 3 under Floor ADJACENT span load ng Live Load Deft (!r) 0.389 0 407 Passed (L503) MID Span 3 under Floor ALTERNATE span loading Total Load Let (in) 0 -447 0 815 Passed (U437) MID Span 3 under Floor ALTERNATE span loading TJPro 48 30 Passed Span 3 - Deflection Criteria STANDARD(LL L 48 TL L1240) - Ceflection analysis is based on composite action with single layer of 19/32" Panels (20" Span Rating) G_UED & NAILED Nccd decking. - BracingiLu) All compression edges ;.top and bottom) must be braced at 3' 3" o/: unless detailed otherwise Proper attachment and positioning of lateral bracc,ng is required to ach - e member stability -203- Ibs eoncertrated load - eqL remerts for standard non - residential 8cors have been conssoered for reaction and shear -The goad so ^,dit i is conside r _tits design araiysis include alternate and edlacent member pattern lcadirg TJ -Pro RATING SYSTEM -The TJ -Pro Rating System value provides adddiona' fleet performance riformatior and is based en a GLJED & NA LED 19/32" Panels (2o" Span Rating) decKing Ille ccntrC w y an is supported by mat_ .- ..dditio,al considerations for this raur_g include Ceiling - None. A structural analysis of the deck has not been performed by :he program Conpu!isen ,aiu_ 1 _ ADDITIONAL NOTES: - IMPORTANT! The analysts presented is output from sdf*.ware developed by iLevel D iLevel'J warrants 1-re sizing of its products by this software will be accomplished in accordance with iLevelt product ceslgn criteria and code accepted design values. The sceptic product application, input design loads, and stated dimensrns have been provided by the software user This output has not been reviewed by an Level', Associate. -Not all products are read ly available Check with your supplier or iLeveina technical representative for product avallaoility. -THIS ANALYSIS FOR LevePD PRODUCTS ONLY' PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS. Allowable Stress Design methodology was used for Building Code UBC analyzing the iLevel(F) Distribution product listed above. PROJECT INFORMATION: RexDurd Outpatient (-l:nic OPERATOR INFORMATION: Lean `racy GSS Structural Ergireers 1 .6oJ John Adams Parkway Suite 200 Nano =alts, ID 83401 Phone (208) 523 -6918 Fax :;208)523 -6922 gs r@gsengineeis net j. y S: SM ."-'I _ 11 7/8" TJ I® 560 @ 16" o/c 7J -6 � 3i5 ra'v :n - de nC�103'?5 Lser n <LG39 -P4� AfI THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS Pad - _ngtneversion 8 ° -01 FOR THE APPLICATION AND LOADS LISTED Or. [itmensior: 4 6' 6" 15 Pron:+uc,1` "ram is Ccrrceptuai, 4' LOADS: Maximum Analysis is for a Joist Member'. Result Location Shear (Ibs) 1584 1428 Primary Load Group - Office Bldgs - Lobbies (psf) 100 0 Live at 100 l duration. 20.0 Dead SUPPORTS: 3455 Passed (87 % Bearing 3 under Floor ADJACENT spar. loading Mome , i: Ft -Lbsi -456 -4567 950) Input Bearing Vertical Reactions (Ibs) Detail Other Passed (L/728) Width Length LivelDead /Uplift/Total 0 815 Passed iLr633) 1 Stud wall '3 50' 2.25" 925: 164' 0 i lo90 A3. Rim Board 1 Ply 1 U4" x 11 7i3' 0.8E Td- Strand Rim Board i 2 Stud wall 5.50 5 50" 238E i 428 1 0 / 2813 B3 Nore 3 Stud war S 50" 6.50" 2523 ; 467 i 0 r 2990 83 None 4 Stud wal 3.50" 225" 992 1 131 / 0 ? 1173 A3: Rim Board 1 Ply 1 ti4" x 11 7/8" 0.8E TJ- Strand Rim Boarddi - CAL TION: Regured bearing length(s) exceed the minimum shown in the iLeverb Bun cer's guide for single family residential appl cations. L mite End supports. 3 1 2' Inlarmedia!e supports. 3 V2" with web stiffeners and 5 1;4" without web stiffeners. -See iLevelti Specifter's,13widers Guice fordetail(s' A5: Rim Board,B3 DESIGN CONTROLS: Maximum Design Control Result Location Shear (Ibs) 1584 1428 2050 Passed (70 Lt. and Span 3 under Floor ADJACENT span loading Vertical Reaction (Ibs) 2590 299C 3455 Passed (87 % Bearing 3 under Floor ADJACENT spar. loading Mome , i: Ft -Lbsi -456 -4567 950) Passed (48"ci Bearing 3 under Floor ADJACENT span loading Live Load Defl (m/ 0263 0 407 Passed (L/728) MID Span 3 under Floor ALTERNATE span loading Total Load Cell !ini 309 0 815 Passed iLr633) MID Span 3 under door ALTERNATE span loading TJFrn 53 30 Passed Span Deflection Criteria. STANDARD(LL :L'480.TL L!240) - Deflection analysis is based or composite action with single layer of 19132" Panels t20" Spar Rating_) GLUED & NAILED wood decking. - BracmgiLu) All compression edges stop and bottom) must be braced at 7' 2" olc unless detailed otherwise Proper attachment and positioning of lateral bracing is required to - icri eve member stability -2000 Ibs coneertraied load - egi.irements for standard non- res ;dentiai floors have been considered for reaction and shear. -The load conditions considered r :h s design analysis'nclude alternate and adjacent member pattern goading TJ -Pro RATING SYSTEM -The T_Pro Rating System value provides additional Floor performance information and is Eased or, a GLUED & NAILED 19/32" Panels (20" Span Rating) decking he ccntro t ry can is supported by walls- Additional considerations for this rating include. Ceiling - None. -A structural analysis of the deck has not been performed by :he prograr Comparison 4 a is 2 2 ADDITIONAL NOTES: -IMPORT ANTI "he analyss presented is output from software developed by iLevelr2T iLevelcD warrants the sizing of its products by this software will be accorrphs led in accordance with iLever(D product design cr'deria and code accepted design values- The specific product application . input design loads, and stated dimensions have been provided by the software user This output has not been reviewed by an ILeveIC Associate. -Not all products are readily available. Check with your suppler or iLevelz technical representative for product availab lity -THIS ,ANALYSIS FOR iLeveln PRODUCTS ONLY! PRODUCT SUBSTITUTION VCIDS THIS ANALYSIS. Allowable Stress Design methodology was used for Bur ding Code UBC analyzing the iLevelt3� Distribution product listed above. PROJECT INFORMATION: Rexburg Outpatient Clinic OPERATOR INFORMAT Dean Tracy G &S Structural Engineers 1600 ,;ohn Adams Parkway Suite 200 Idaho Fa is ID 83401 Phone(208)523 -6918 Fax (208) 523 -6922 gs @gsengineers net 11 718" TJ10 360 @ 16" O/C TJ -Beam 6.30 Serial Number. 700 User, 5r8J2608 8 56 57 AM THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS -e Efigneversb E3013 FOR THE APPLICATION AND LOADS LISTED i Dimension: 25' LOADS: Analysis is for a Joist Member. Primary Load Group - Office Bldgs - Lobbies (psf ;. 100.0 Live at 100 1 % darat on, 20.0 Dead SUPPORTS: 16 . 6 ,. PYOdUC -iarit t is CpnCel)ZLI3L Input Bearing Vertical Reactions (Ibs) Detail Other Width Length Live /Dead /UplifUTotal Stuo wall 3 50' 2 25" 534 / 36 ' -317 ' 570 A3 Rim Board 1 Ply 1 114' x 11 7/8" 0 8E T.-Strand Rim Board,1) 2 Stud wall 5 50" 5 50" 2243 1 4 : 0 ! 2691 B3 None 3 Stud wall 3 5C' 225' 934 1 182 / 0 i 11 16 A3. Rim 3oard 1 Ply 1 14" x 11 'I8" 0.8E TJ Strand Rim Board0 - CAUTION Required bearing leog1i exceed the minimum shown in the iLevei�� Builder's guide 'or single family residential appI cations supports. 3 1:2° with web stiffeners and 5 1/4" withoutweb stiffeners -See iLevel40 Specifier 'sBwlder's Guide for detail {s): A3: Rim Board .B3 DESIGN CONTROLS: Maximum Design Control Result Location Shear ilbsi 1545 1371 1705 Passed (80 °rat Lt end Span 2 under Floor loading Verical Reaction (Ibs) 1083 1083 1202 Passed (50°4,) Bearing 3 under Floor ALTERNATE span leading Moment (Ft -Lbs) -3982 -3982 6130 Passed i64 °m) Bearing 2 under �lcorloading Live -cad Den (in) 0.314 0 407 Passed (L622) MID Span 2 under Floor ALTERNATE span loading Tctal Load Dell (in) 0.372 0 815 Passed !L,'526j MID Span 2 under Floor ALTERNATE span loading TJPro 47 30 Passed Span 2 Lim is End supports. 3 112' Intermediate - Oeflectlon Criteria. STANDARD(LL:L480.TL:L240) -Uplift exceeds 200 Ibs for unbalanced load. - Defection analysis is based on composite action with single layer of 19132" Panels (20" Span Rating) GLUED & NAILED wood decking -Erac ngiLu All compression edges (top and bottom} must be braced a 1" o/c unless detai'ed otherwise. Proper attachment and positioning of Ia:eral bracing is regwred ta - chie member stability -2000 Ibs concentrated load - equirements for standard non - residential 'loors have been consiaered for reaction and shear The load ce considered in this design analysis include alternate member pattern Icar i. TJ - Pro RATING SYSTEM -The TJ -Pre Rating System value provides additional floor performance irformation and Is based on a GLUED & NAILED 19,32" Pane's (20" Span Rating) decking. The cone oil nu span is supported by walls Additional considerations for this rating include. Ceiling - None A structural analysis of the deck has not been performed by the program. Comparison Value : 69 ADDITIONAL NOTES: - IMPORTANT! The analysis presented is output from software develooed by r_evela ii warrants the sizing of its producs by this software will be accomplished n accc dncce with iLeve l! product design criter a and code accepted design values. The specitc product application input design loads, and stated dimensions have been provided by the sct,ware user. This output has not been reviewed by an (Level (D Associate. -Not all prcduc:s are readily available- Check with your supplier or ILevela technical representative for product availability -THIS ANALYSIS FOR iLevely PRODUCTS CNLYi PRODUCT SUBSTITUTION VCIDS - lS ANALYSIS - Allowable Stress Design methodology was used for Budding Code UBC analyzing the ILeveiIF) Distribution product listed above, PROJECT INFORMATION: Rexburg Cutpatlent Clinic OPERATOR IN FORMATION: Dean Tracy G&S Structural Engineers '600 John Adams Parkway Suite 200 Idano Falls, ID 83401 Phone _ (208) 523 -6918 Fax : (203) 523 -6922 gs@gsengineers net Project Project No. C'7f Date Designed By r 17/ Av - p i e a , - v ;& L � J - 71 �1y>7 YO,4,r ' 4 j 4 A ��'7k G&S Structural Engineers Sheet 'Y C" Project_ Designed By Project No. Date -- / 4 q K c 4r G&S Structural Engineers Sheet y, / G & S Structural En- • I 1',o) John Mom Park aiiilc 20(: Idaho FitA, tl-). 83-It'll JOB TITLE ReXI Otltjldticllt (" JOB NO 1 SHEET NO. CALCULATED BY DATE CHECKED BY DATE , At \\ i;o I PA i I! C i 0 11, Co Cie 5 I. Code: 111tel national I ItlildiiiL ode '00(, 11, Occupancy: 0,:Ct1pm1C\ Group = R kc,i(ielltiiil III. Type of Construction: I Ire fkatinu: Roof= 0.0 lif Floor = 0.0 !11 IV. Live Loads: ROM EIM Root C (0) Imo 4,8 dlLn�_ 0 to -'0o ,-;I` 21) ps!' lot, to hAitl SI ' - i bit 1101 lci5 [11,111 2 psj (), er ('00 >j 12 1)-;1 Floor I im pst Stairs & ExitNN a\ s I 0t) P Balcoll� N Mechanical N,'A Partitions N1,A V. Wind Loads : ASCE7-05 Iripol F actor 1-(u 111ph (lid) (L Mean Roct'llt (h) � 0 I 11 1 1-apct 1 abo% c Lml 10 it F\po.mirc (,ategor� I- 1 I o. C lassil. Enclosed Iluildtug hitLmiL] pre;;ure I Wilklim-) lcm- (L) 1 _"4.o It I ca;t \\ idth (11) 93'o it kh Case I Kh Case it 94�; aw Factor (Kit) - H - -------------- opoumipll% Flat ( till I Icit!ht (1-1) U.0 t". eml C I h1t I lilt Lemith (111) o It ESCARPMENT A,:Iuai IIJ = (i.0o o.0o N'todifie't I'll It, i om top o i'crcst: x= ("o It 7 Ix. I1,IdL tip/do N a wind? Jm\ Im slid I I/Lli� 0 X U.I ........... K, ------------ /111 = 0,00 K, Nh:jil Root I It 2D RIOGE or 3D AXISYMMETRICAL HILL G & S Structural Engineers ';('00 lohn Adam, ParkvaN .'Mite; 20o Idaho Falk. ID. 53 JOB TITLE OWPLILicill Chllic JOB NO SHEET NC. CALCULATED BY DATE CHECKED BY DATE V. Wind Loads - MVVFRS h <_ISGLLL.w-_rise BuilditRS1 �Encl.sed/artia�llenclosed onl Can �iuua�l loads arc Scc code Im I diaummi L; 4 )L 1 I C L S t I I I c icpt, (icpi (jc'pt -6cpi - (jcpt 6 4 u 5 _0 -o.3 -0.19 5 -o -4 I'' (I'll - o.-17 - t).-,9 - 1) . 1 l - 0 4� - 0.2 - - il).o , - - (j, 4 S S 0,4, 4, ti �E Transverse Direction Lomitudinal Direction lei = Kh = 1) 1) 1 dLc Strip 16 7 pst ild zonc Ga ) (;Cm 1. 1 x, /C)Iic - IcIl4111 Can �iuua�l loads arc Scc code Im I diaummi `Lindy xd roof overliall'IL": 11.3 ]),,1' (up arc:) add to " iild%v -rd root prcLsstirc Parapet Wiiidkt aid parapet j.0 pst (GcP11 = Levu and parapet: o,o pst ((;Cpll = Horizontal NINN FRS Simple Diaphragm Pressures Ipsf) Trams erne direction (normal W L) liltLfllm /cAw: W(111 lls I' Kuol p. End /.one: Wall 1 pst Root -9,0 psi a direction (parallel to L) luterior /one: all 11.` pst I nd Imic. Wall psl q, 9 Transverse Direction Low- Direction 4 )L 1 I C L S t I I I c icpt, (icpi (jc'pt -6cpi - (jcpt 4 u 5 _0 -o.3 -0.19 5 -o -4 I'' (I'll - o.-17 - t).-,9 - 1) . 1 l - 0 4� - 0.2 - - il).o , - - (j, 4 S S 0,4, 4, 2` `Lindy xd roof overliall'IL": 11.3 ]),,1' (up arc:) add to " iild%v -rd root prcLsstirc Parapet Wiiidkt aid parapet j.0 pst (GcP11 = Levu and parapet: o,o pst ((;Cpll = Horizontal NINN FRS Simple Diaphragm Pressures Ipsf) Trams erne direction (normal W L) liltLfllm /cAw: W(111 lls I' Kuol p. End /.one: Wall 1 pst Root -9,0 psi a direction (parallel to L) luterior /one: all 11.` pst I nd Imic. Wall psl q, 9 11 HIII JU IIa t ry .... 4 - 1. 1 14 4 t.S -7 -4 51 -10 -4 S S 41 `Lindy xd roof overliall'IL": 11.3 ]),,1' (up arc:) add to " iild%v -rd root prcLsstirc Parapet Wiiidkt aid parapet j.0 pst (GcP11 = Levu and parapet: o,o pst ((;Cpll = Horizontal NINN FRS Simple Diaphragm Pressures Ipsf) Trams erne direction (normal W L) liltLfllm /cAw: W(111 lls I' Kuol p. End /.one: Wall 1 pst Root -9,0 psi a direction (parallel to L) luterior /one: all 11.` pst I nd Imic. Wall psl q, 9 C; & S structural Em-yineers JOB TITLE OtItImUcill Clilli • I f,of) Joh:uAdams Parkv it\ Suite 2700 JOB NO SHEET NO. daho t CALCULATED BY DATE CHECKED BY DATE V. Wind Loads - Components & Cladding: Buildings K60' & Alternate design 60'<h<90' K/ = tilt I) = (j y ; (X pi til tT: lftribuLir iuc;l I, Llcatcl* 111,11, 16.7psf It 7m i. \,RXTRI; pl n1w, I)c N1 p hciLIMM htllldilil It Root AnL1c= S I %rcot lool Roof i\lci Neeutl\ e Zone Ne2iltl\ e /011c Nc- ii zolic Posviv cAll Lou, 0%, thZill, /one I& (h cl-how- Zolic 1N MIS Postin c /nine 4 P.11 GCp +/- GICT)l 1, uriace Pressure pst') User input - 1 �o sr P j sF I:) '1 50 i f l oo ;I' 20 st' 711 ,t "t - 1 It I (1 1 1).7 pst - ps - I Sk 77 - 19? psi p-il .9S 114 1 28 "" pst -2-1.8 psl -213 psl 10 - 1 0. 8 -1 1 2S pst - p�jj - -21. ps - -111 1 pst _1- 7 P , U.)' S I i ps I I pst psi -27_' pst -27 7 p,t -27 psl so -2',. 1 pst l 3 psl - IN' PI Gcp Gc'pi Surfltce Pressure (pI j User input 10 M' 100 '1 C.O pst (l.0 pst 00 st Soo ,'I �;O A 200 st "t 1.0 0.() psi a; Isl -11 >,o psi - p'l t pst 4 ,1 -0 lio Iii pst -1S P 1 5.0 psl - psl 08 " 2 p S111 S. (j lis I pst Note: 6cp I by (11,10 !0 17001 alIL'Ic , I .�') - 11t " Solid Piaape [ ) re, slll� , I u M 100 st BOO A CASE Illiencl "'Ottic C.O pst (l.0 pst o 0 114( Comer zone (1. U p s. 0.0 )sl "t CASL 1 Interior zone 0.() psi 0.0 psl C omer zone i 0.0 pst 0.0 „I CASE .1= prssurrtav1_ud,buihlinl_ Clow buittfi-- Rooftop Structures & Equipment IlIcz tt) 1j 1k) ccim-nid of Af= 10 I = 1 � U 1 C I os I loll Square Directionality tKit) Idth (D) 'I \ pe of sm la(:c N Al sf Adjustment F actor (Adj) F = +7 G 0 At AJi= 16.2 A f F= 162 lbs Gust Effea I actor (G) = (1. 8 � Ilmsc pressure (ti z) = 2 1.1) K d p f hil ) - I - ` 1 , 1, ."" IlLirc : :int k ilormal to t't,c) A Adjustment Factor (Ai1j) = I t10u F- q,, G C, A Adj= 21.1 A I" - I l I It), Y q G &, S Structural Engineers JOB TITLE Rc\bur A )u1paliell" I w john Adwns Park ,l% tiilitc W) JOB NO. SHEET NO CALCULATED By DATE CHECKED BY DATE ti CICLnce" '11IJ Arno„ lope degrees Location ol'Wind Pressure Z 011 c .4 - --------- --------- -- — -------------- ........... Nlunosloj)o lVol I j < o X10 t dcunces W —' IC21VC S -- — ---------- ------ --- --- ----------- W —' IC21VC S G & S Structural Emginecrs IowJohn Adams ParkwaN Suite 200 Idaho I tills, 11). $34i)l VI. Seismic Loads: ASCE 7 -05 ()ccupanO Categon: 11 impo Micc Factor iD : L00 Site Class : C J JOB TITLE Rcxbure Outpatient Chnlc JOB NO. 7590 _- SHEET NO CALCULATED BY DATE CHECKED BY DATE http legint c uSgs govleg- rren /html /iookul2 2 002- irterp 06.html S,, ( 0,2 sec I 1)0,60 Og Sl tl.0sacl- 19.30 "wa 1 1.158 Sms = 0 702 Sd, = 0.468 Dcsi- n Catc�_uI% Sml = 031(1 Shc =- 9207 Design Cal —orn Seismic Dcsten Categorti'= D Numbcr of Stories: I Structnre T}pe: Light Frame Ilowontal Struct ItrCgularitieS: No plan Irregularit% Vertical Structural hreeularities: No Vertical irreeularit- 11exibiv I )iaphrat_ms Yom, 13uildina S Bearing Will Systems SCiso,ic resisting sSStetn: Light frame walls with shear panels - wood structural panels /sheet steel panels S�stcm Buildirr_ 11ci_2ht Limit 65 ft Adaal. 13uildim* 1leight(hnr 2 SO it See ASCL7 Section 12_' `. J lnr esccptions and other SVstan limitations UtfS[G\ COFGFICIE`TS ,ol) F_1CTORS Kespon,e Modification Factor (R) S% sic m 11%el-Strcngth Factor ( ( = 3.3 Dei]cction :Ampliticatiun Factor (Cd) = 4 Sds ua68 Shc 0207 P iodundmncv octticicni Seismic Load FttcctiF.; = i' O� -�- a ti I? Qe - 0.094D ( 1r - hort4ontal seismic Iorcc s Q n 09.11) D dead load Special Seiamic Load Effect (L) ?o 12 U._S - PERNIL'CTED _AA.A1,N'l'IC.AL PROC'EDC RES Index Force _ Analysis (Seismic Cate e01'y _A only) Method Not Permitted Siwplilied nalysis [ ?se Equivalent Lateral Force Anal�si> Equivalent Lateral -Force Analysis Building period coe[. (C _ Pennitted 0.020 Approx tnndamentat period (Tm = C III , ' - llscr calculated tGmdantental period (T) _ Lom__ Penod t ransition Period iTL) Seismic resporse coet. iCS 1 - SItst IZ = need not exceed Cs but not les, than Cs = USE Cs = Cu = 1.-1 0.224 sec ;= tl 7 Tmax = CttCa = 0 334 u sec 1,c T - 0.'3.1 b 0.07- 0. ti2 (10 1 a 072 Desien Base Shear V = 0.072% Nlodel & Seismic Response.�nalysis - Pemutted (-see Cade [or procedure) :NLLO�b.ABLI? STORM DRIFT SlrcCtUre h Ott other strucRites Allo story mitt - 0.020hsx where hsx 1s the story height below levels C 1) '3. & G & S Structural Engineers I (,00 jotter Adams Par''<wat tiuitc "JIi iddilo I =ills. 11) 8.jdti i VII. Snow Loads : ROOI *;Iope = J.3 dc l 1( I/ tlal c to rid ^_c dist (V) tt 12oo Cn_th paraliel to ridge (L) = 124 o it 1'tipe >' Riot llip )r 2a111e tinanui Load I'L �0.011sf lmp'liance Categ+trp - 11 Importance factor 1 LO lhcrmdl Pactt,l Ct = LOG f�p0surc factor C'c = LO Pt min = U j psf I fat Root Snuw Load Pf = O list R.iin on ,11o'.\ Surchar_e = 0.0 psf I rn)b,mlcicd slipper tillrlac, (per Sectitin 7 1) = 110 Slepeci -root factor Cs 100 JOB TITLE ResborgOutpatient Clinic JOB NO. 7 SHEET NO CALCULATED BY DATE CHECKED BY DATE EXposurr FacKrr. lc 35.0 psf I 'balanced' I?slx� sure of io( Terrain F ulh Partlulls ti hdtcrcd A nJa I 13 1; design roof snow to 1d ,0 as 10 produ�c 1!1c >411nililllil 1�tll�dil7g l)li lCtal - I19 I ti I I t) 0 A 0 -y LO :\hove treeiine 7 n X n u : \laska - iw trees [i I I) X n :l Design Roof Snow Load (Psl - 35.0 psf I 'balanced' NOITi Altentatc spans ul continuous beam- - and outer turns shall be ixlded n ill' hall the = �. O design roof snow to 1d ,0 as 10 produ�c 1!1c >411nililllil 1�tll�dil7g l)li lCtal - Pst greatest ptssiblc Cfll -ci - ;cc ct;dc. I nb lftnced Snow I mute - for Dip & Gablc roofs onlc '-I balanced loads must he applied or 7 0 \1 - O � ` des 1 - snu11 Wind"tard snow 10ad= 10 p,l I Ccv�ird;uow htad from ri i_e :o': } _ >Lo p,l - hd. Leas and .;now load from 'I' to [ha ease Lcess Snoss D I ifls - tlo n adia cuu itighel ro�1f l;pt cr rovf ILn nth ItI ;0 I) it Lu Projection -- --- - - - -.— ItUitdi111 Se'1)HCa[lpn s = 1).(1 TC SU�Ln y'B lJail \'dltll'l'nt itrllC iaeUlr l .(1i) Due t0 Cf'.1',N snt density = 30.5 per 1 >f. fta alud snort height hb - 171 it h h C hd� d P �v t he — -19 it � _ k r ? Qdf20 2 r ti _;aJ 11C 111) -u.' hcrcforc, design for drift h — r t r r t t e v e r t )rill, height hd = 21)i I: Vd I )rii't tt idth tt = 11_(�a it Surcharge load pd _ , _•hd = 59.6 psf i nrhsard Sn (ss Drifts - .against walls. unrapcts, etc m ore than 11 =` long Ruildin__ roof len_th lu = ;o) It Projection heilaht h = 4 s it snow denzlty = 30.> PC I' Balanced ,;now heia_ht hb 171 ft Ilk = '_79 it 1.6 Therefore, design for drift Drill hclttlll lid = _ I X It DI ill 1tidth w = B7 ti Surcharsc it)ad pd = __`hd = 14.7 psf y,'l • Project Project No. Data Designed By G&S Structural Engineers Sheet l , 0 ,Y .z _.x - 9k /ft -.9klft -.9klft 1.4k iSS16X N i \ I HSS16-X4X8 Loads: LC 1, total Solution: Envelope Ulmer Smith Residence dmt 7341 XI Ui z; May 7, 2008 at 1:37 PM 7590 brace r3d • Company May 7, 2008 Designer dmt 1:39 PM Job Number : 7590 Rexburg Outpatient Clinic Checked By Global AISC. ASD 9th _ Display Sections for Member Calcs _ 3 _ - _____7 Max Internal Sections for Member Calcs 9 Include Shear Deformation Yes Include Warping Yes - - -- (in Area Load - -_ 144 ^2} nce Merge Tolera (ink _ 12 P -Delta Analy Tolerance 0 ,5 0 % _ Vertical Axis - -- Hot Rolled Steel Code AISC. ASD 9th _ Y_ [ft] 16 _____ ° - - - - -- - - - - -� $ - - -- — - - -- -- - 0 - - Cold Formed Steel Code AISI 99: ASD -_ RISA -3D Version 7.0.2 [C \... Wood Code _ NDS 91W A - -- - - Wood Temperature - _ < 100E ___F Concrete Code ACI 2002 _ Number of Shear 4 Region Spacing Increment (in) _ 4 Biaxial Column Method PCA Lo Contour - Parme Beta Factor (PCA) 65 - Concrete Stress Block _ _Rectangular Use Cracked Sections -- - Yes Bad Framing_Warnings No Unused Force Warnings - __Yes Footing Overturning Safety Factor Check Concrete Bearing - -__- Yes Self Wt, Overburden in DL for Design Footing Concrete Weight 145 k /ft ^3 Footirg Concrete f'c Footing Concrete Ec 4000 ksi Foot ing_Steel fy 60 ksi Minimum Steel - 0.0018 Maximum Steel 0 0075 Footing Top Bar - #3 Footing To p Bar Cover 3.5 in Footing Bottom Bar _ Footing Bottom Bar Cover - _3.5 in Pedestal Bar - Pedestal Bar Cover _ 1.5 in — - - - Pedestal Ties #3 _- - - -- -- - Hot Rolled Steel Section Sets Label Shape _ Type Design List Material Tube A500 Gr 46 Design_Rules- A [in2] _ lyy [in4] Izz [in4; J [in4] Typical 17,178 46.971 454.899 149.54 1 beam HSS16x4x8 Beam 2 col HSS4x4x6 Column _ Tube A500 Gr.46 _ Typical 4.78 10.252 10.252 17.457 28.276 32.784 3 diag HSS6X4X6 VBrace Tube A500 Gr 46 Typical 6,175 14.916 Joint Coordinates and Temp eratures Label -- 5 6 6 - — - - -- X [ft] - — - -- 6 -- - - - 42 -- — - - -- - - -- Y_ [ft] 16 _____ ° - - - - -- - - - - -� $ - - -- — - - -- -- - 0 - - Z [ft]- - -- 0 0. — -- 0 - - - - -- -- -- - - - -- Temp [F] Detach From Diap -- - - - - -- — - - - __O_ -- 0 RISA -3D Version 7.0.2 [C \... \dean \My Documents \2007 \7590 Rexburg Outpatient \7590 brace.r3d] Page 1 �, L Company May Check 7, 2008 PM Designer dmt 1:39 Job Number : 7590 Rexburg Outpatient Clinic d By _ Member Primary Data Label I Joint J Dint K Joint Rotate(deg)_ SectioniShape_. Type Design List Mat 4 A G Gr Design Rules Typical 1 1 2 beam _ -- Beam __ Tube 6 MZ [R -ft) Ic J 1 1 2 3 beam _ Beam__ Tube A5o0 Gr 46 Typical 2 2 - 0 - 3 -- - 4 - beam Beam Tube ASOC Gr ae Typica, 3_ — 5 - 3- - - - - - 1 -0 0 ASOO Gr.46 Typical yp 4 4 6 max 0 - 4 - _col_ _' .Column col 1 Tube A5o0 Gr.46 Typical 5 5_ _ 6 _ _. - _ dial _ VBra e Tube A5c0 Gr a6 - Typical 6 6 ___ 5 _ _ -- 2____. 0 __ 0 1 0 1 Load Combinations Description SolvePD.. SR... BLC Facto, BLC Factor,BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor BLC Factor 1 total Yes Y -1 1 1 2 1 _ 2 .9 D+ lat Yes Y -.9 1 .15 2 1 Envelope Joint Reactions - Envelope Joint X [k] Ic Y [k] is Z [k; Ic MX [k -ft] Ic MY [k ft] is MZ [R -ft) Ic J 1 1 5 max _7 4- 1 2817 1 0 1 0 0 1 0 1 1 C 1 2 - min -14 - __2 5.394 2 0 - - 1 - - - 1 -0 0 _ 65- _ C 1 .473 6 max 0 ___ 1 13.079 1 1 - -- C _ 0 1 0 1 0 1 4 min - - -- 0 2 3.341 - - 0 3 1 1 0 1 0 1 0 1 5 3 max 0 - 1 0 1 1 0 .238 - -0 _ - 1 1 - - 0 1 0.__ 1_ 6 (- - Min-- Totals max -1.4 - -1 1 _ -_0 41, 249 1 _0__ - 1 - -- 1 1 -002 2 1 0 0 g - min -1.4 2 $ - -- 2 - C 1 - m in min 689 - Envelope Joint Displacements - Envelope Member Sec Joint AxialLk] X [in] Ic Y [in] Ic Z jin; Ic X Rota.ron . _ Ic Y Rotation _ c 1- Z Rotation I 3.238e -3 c 2 1 1 nax 943 -_116 .649 1 0 1 1 0 0 1 1 0 0 1- 4.112e -3 1 2 Min min _ 65- _ 2 .473 2 0 1_ - 0 1 0 1 -3 335e -3 2 3 2 max .968 1 .347 1 0 1_ 0 1 0 1- 4.515e -3 1 4 min min__- .669 - 2 .238 2 0 1 0 1 0 1 -3,1 2 F 3 max 1 1 -002 2 1 0 0 -- 0 0 1 1 1 3 1 6 m in min 689 2 -035 0 -. 0 0 _ - 1 1 0 1 0 1 9.217 9.217 e -3 1 7 4 Max 999 1 -.005 2 1 1 1 0 1 2-725e-3 , $ min min 689 2 -_02 1 0 0 __C, 1_ 0 1 3.377e -3 2 9 5 max 0 2 0 2 _ 0 1 0_ - 0 1 0 1 . - - 4.9e -3 1 10 _ min _ - min 0 1 0 1 0 1 -. 0 1 0 1 - 3.19e -3 2 11 6 max 0 2 0 2 0 1 0 1 0 1- 4.625e -3 1 12 brace.r3d] min 0 1 0 1 0 Member Section Forces - Envelope Member Sec AxialLk] is y Shear[k] _Ic_ z Shear[k] Ic . Torque[k -ft] 11 y y MOmen.. i1 z z MOrnen. I 1 1 1 m_ ax 1.395 2 _ -_116 1 0 1- 0 - 1 0 1 0 1 2 Min 1.395 1_ - 1.16 2 0- 1- 1_ : -4 0 0 1 8 1 3 2 max 1.348 2 - .679 -_ 2 -- 0_ 1 1 0 1 1 1 1 .191 2 4 min 1.156 1 - 2.992 1 0 -.- - 0 0_ 1 0 1 18.012 5 3 max 1.301 2 1_,2__42 _2 0 1 1- -- 0 1 0 1 4.089 2 6 m in 916- 1 - 5._867 - 1 0 -. 0 1 0 1 0 1 18 012 1 7 2 1 max 212 2 2.546 2 0 1 0 1 4.089 2 g min -_ 175 1 -2.098 1 0 1 1_ 0 1 0 1 28.555 1 9 - 2 max 165 __ 2 1 983 2 0- _ 1 Q 1 0 1 -2.727 2 10 _ min _ - _- ._ 1 -4.973 1 0. _ 0 1- 0 47 955 1 11 3 max 1' 8_ 2 1.42 2 0_ 1 - (CA. ldean \My Documents12007 \7590 Rexburg Outpatient\7590 brace.r3d] Page 2 �n 7.0.2 RlSA -3D Version y�i . Company May 7, 2008 Designer dmt 1.39 PM Job Number 7590 Rexburg Outpatient Clinic Checked By: Envelope Member Section Forces (Continued) Member Sec Ic y Shear[kj _Ic - z Shear[_kl -_. :c _Torque[k -ft1 Ic _y -y Momen.._ Ic_ z -z Momen, Ic 12 _Axial[1 min -.654 1 7.849 1 -- 0 1_ -- 0 - -- 1 - - -- G 1 - 7.34.9 2 - 13 - 3 1 -- max_ 1_ _- 15 974 1 . _ 0 1 ___ 0 1- _ 0 1 47 955 1 14 min _,532__ -_ 2 553 2 -__ 0_ - 1- 0- 1 0 - 1 -7.849 2 15 -? max _,085 - - - - 053_ - 1 1 598 1 0 -- 1 0 1 0 1 -25 042 2 16 - -_ min_. -, 2 - 26 2 0 1 -- - -0 1 0 1 - -83 c�09 1 17 3 max_ - 103_ - - 2_ -3 076 2 0 1 U -- 1 - 0 1 0 1 18 m1 n__ 1 -12 779 1- - _0 1 :. - - - -- - 1 0 1 1 _ 19 _ 4 1 . _426 24 136 ._ 1 0 1 0 __ .. 0 - 1 0 1- 0 20 _max_. 1.378 - - -- 8 - - 0_ - - 1 - - 0 - 1 0 1 _ 0 1 21 2 -m in' max - - 23.997 1 __ -- 0- 1 0 - -� 0 1 - 0 - 1 _ 0 1 22 _ 1.254_ 2- 0 -__ - 1 - 0 - -_ .. -- - -0 - -- 1 - 0 - 1 0 __- 1 -- 23 3 -min_ max _ 23.859 0 1 - 0 -- 1 .. 0 - 1_ - 0 1 0 1 24 -._ min_ 129 -1 2 0 1 0 - 1 --- -- 0 _ -- 1 _. __ 0 1 0 1 25 - 5 - 1 max__ - 1_ 13.0 9_ 0 1 0 1 -- 0 - 1 __ 0 1 - 1 26 min 3.341 .1_ 2____ 0 - 1 0 - - 0 1 0 - _.. 1- 0 1 .. 27 2 12.933 1 -1 - 0 _ 1 - 0- 1 0 - -1 _ 0 1 28 . max_: min_ 3 209 2 -0 -- 0 - 1 0 1 -- 0 1 - 0 1 0 1 2G - _ ._ - 3 max _ 12.786 -_ 1 -- 0 1 -.- 0 _1 0 _ 1_ 0 -- 0 1 30 mi 3.077- 1 - - - - - - 1 - 0 - 1 - 0 1 0 1 31 - 6 1 max. -2 4 27 _ -- 1_ -0- 063- 1 - 0. -- 1- - 0- -. 1 0 1 0 1 32 min -- 4.253 2 057_ 2_ . 0 1 - -- 0 -- 1 - _ _ 0 1 0 1 33 2 _ 4.097 2_ 0 -- 1 -. 0 1 - - .0 1 0 1 249 2 34 _n�ax_. min 4.097 1 _ - 0.- 1 - 0 - -- 0 ___ 1 0 1 - 277 35 3 _ max_ 3 941 2 -. 2 -- 0 1- 0 - 1 -- 0 1- 0 36 - mi_n_. 3.923 -__ -1 -.063_ 1 _ _ 0 -- 1 = 0 -- 1 - 0 _ _ 0 1 Envelo a Member Section Deflections Member Sec x [in] Ic y_[ir] Ic z ;in] Ic x Rotate [r Ic (n) Uy Ratio Ic (n) Liz Ratio is 1 1 1 max 993 1 _ 568 1 0 1 0 1 NC 1 NC 1 -2 min .687 2_ 417 2 _ 0 1 - _ _ 0 1 NC 2 NC 1 3 2 max _ .993 1 42 1 0 1 - 0 1_ NC 1 NC 1 4 min ___ 687 2- _ .3 0 1 0 -__ 1 NC 2 _ NC 1 5 3 max 993 1 265 -2 1 0 1_ 0_ __1 NC 1 NC 1 6 min 686 2 .182_ 2 0 1 _- 0 1 ,_ NC 2 NC 1 7 2 1 max .99.3 1 .265__ 1 0___ 1 _0 1 NC_ 1 NC 1 8 min .686 2 182 2 0 1 0 1 _300,024 2 NC 1 9 2 max 99 3 1 .091 1 ___ _ 0 1 ._ 0 _1. 4143 663 1 NC 1 10 min - 686 2 .06 2 0 1 ._ 0 1_ , 607_.79.7 2 NC 1 11 3 max .993 1 - - 059 2 0- 1 0 1 NC 2 NC 1 12 min .686 2 -.118 1 0 1 _'_ 0 NC 1 NC 1 13 3 1 max .998 1 -_025 2_ 0 1 0 1 - _ NC 2 NC 1 14 min 689 2 -.069 1_ 0 1_ 0 1 NC 1 NC 1 15 2 max 998_ 1_ -.344 2 0 1_ __ 0 1 1134.441 2 NC 1 16 min 689_ 2- -1.034 1 0 1- 0 1 - 370.349 1 NC 1 1 r 3 max .998 1 -.028 2_ _ 0 1_ 0 1 NC 2 NC 1 18 min .689 2___ -.053 1 0- 1 _ 0 1 _ NC 1 NC 1 19 4 1 max 0_ 1 -0. 1 0 _1- - 0 1 NC 1 1 NC NC 1 1 20 min 0 1 0 _1 0 1 __ _ 0_ 1 1 NC NC 2 NC 1 21 2 max 0 - _ 2_ -.344 2 0 0_ 1 - 1 - - 0 1 NC 1 NC 1 22 23 3_ min max - -01 -8 - 002_- 1 2 - .5 - .689- 1 2 _ - 0 - 1 -' _ - 0. 1 __ NC 2 NC 1 24 min - 035 1- 1 1-__- 0 1 0 1 NC 1 _ _ NC 1 25 5 1 max 0 . 0 1 0_ 1 0 1 NC 1 NC 1 26 min - _1_ 1 0 1 0 1 0 1 NC 1 NC 1 27 2 max _0 - .003 2 345 2 0 1 0 1 NC _ 2 NC 1 28 min _ -,01 1 - .5 1 0 1 0 1 NC 1 NC 1 RISA -3D Version 7 02 [Ca._\deanWy Documents12007\7590 Rexburg Outpatient \7590 brace.r3d] Page 3 • Company May 7, 2008 Designer dmt 1 39 PM Job Number : 7 590 Rexburg Outpatient Clinic Checked By Envelope Member Section Deflections (Continued) - Member Sec x [in] c y [ n] Ic z [in] Ic x Rotate [r.__ Ic (r) Ly Ratio Ic (n; Lz Ratio Ic 29 3 max -.305 2 - .689_ - 2 - 0 -_ 0 -.- �- _ NC 2 NC 1 30 N C - 02 -1 - 999 �- _ 0 _1- 0 NC 1 1 31 6 _min _ max __ 0._ 1 0 0 1-- - - - - 0- 1 NC 1 NC 1 32 m _ O- 1 0- 0 1 0. 1 NC - 1 NC 1 33 -- 2 -- -002 1 4 . 9 . 5 1 - 0 1. 0 — 1 425.403 1 _ NC 1 34 - _max_ min_ - -.002 2- 338 2 0 - 1- 01 1 622.971 2- NC 1 35 3 005 1 1 028 1 0___ _ __ 1__ 0 - -- - 1 . 204 954 1 NC 1 36 _max_- min - 005 21-- .7 _ _ 0 _ 1- . _ 0 1 " 29&703 2 NC 1 Envelop AISC ASD Steel Code Checks Member Shape C .. Loc[ft] Ic Shear Loc[ft: Dir is Fa [ksi] _ Ft [ksi] Fb y -y [._ Fb z -z [_ Cb Cmy Cnz ASD Eqn 1 1 -_Code HSS16x4XS 127 6.021 1 021 6 021 v 1 23 516 27.6 27.6 30 "36 1 5 85 H1 -2 2 2 HSS1 6x4x3 .335 : 6.021 1 029 6.021 y 1 23 516 27.6 27.6 30.36 1 - 6 .85 H2 -1 3 3 HSS15x4x8 .652 16.54- 1 .058 0 v 1 3 147 27,6 27.6 27.6 1 6 85 H1 -2 4 4 HSS4x4x6 .656 0 1 000 C z 1 7.696 27.6 27.6 27.6 1 - .6 .6 H1 -", 5 5 HSS4x4x6 .399 0 1 .000 0 z 1 6.864 27.6 27.6 276 6 6 H1 6 6 HSS6X4X6 095 _7.524 1_ .001 0 y 1 8.126 _27.6 27.6 _ 27.6 1 .6 1 H1 -3 RISA -3D Version 7 0.2 (C: \... \dean \My Documents \2007 \7590 Rexburg Outpatient17590 brace.r3d] Page 4 517 Company May 7, 2008 Designer dmt 2:13 PM Job Number : 7590 Rexburg Outpatient Clinic Checked By. Global Display Sections for Member Calcs Max Int ernal S ections for Member Calcs 99 Include Shear De formation Yes Include Warping Yes Area Load Mesh (in ^2) 144 Merge Tolerance (in) 12 P -Delta Anal sis Tolerance 0.5c Vertical Axis Y Hot Rol Steel C ode AISC. ASD 9th Cold Foed Steel Code rm AISI 99: ASD Wood Code NDS 91/97 ASD - Wood Temperature _ < 10O __ -- - Concrete Code ACI 2002 Number of Shear Reg ons -_ _- -_- -._4 -_ Region Spacing Increment (in) - -_- 4 Biaxial Column Method PCA Load Contour _ - - Parme Beta Factor (PCA) _ __. Concrete Stress Block - _:_Rectangular - Use Cracked Sections Yes _ Bad Framing Warnings -- No - - Unuse Force Warnings Yes - Footing Overturning Safety Factor_ Detach Check Concrete Bearing Yes Self Wt Overburden in DL for Design No - - - — Footing Concrete Weight .145 klft_ 3 -_ Footing Concrete f'c 3 ksi - Footing Concrete Ed - 4000 ksi Footing Steel fy _60 ks Minimum Steel 0 0018 -0 - - Maximum Steel 0075 -- - -- - - _ _ Footing Top Bar - #3 Cover r Footin Top e 3 5 in _Bar Footing Bottom Bar #4 Footing Bottom Bar Cover Pedestal Bar _ Pedestal Bar Cover 1.5 in -__ --- --- . _ Pedestal Ties #3 Hot Rolled Steel Section Sets Label Shape Type Design List Material Design Rules Typical A [in2] 17.178 lyy [in4] 46.971 Izz [in4; 454.899 J 149 9 5 4 5 1 beam HSS16x4X8 Bea -m Tube - Tube A500 Gr.46 A500 0r.46_ Typical 85.519 85.519 135.729 2 _ col HSS8X8X5 Column_ 3 diag HSS6X4X6 VBrace Tube A500 Gr 46 - Typical -8.745 6.175 14.916 _ 28.276 32 784 Joint Coordinates and Temperatures X [ft] Y [ft] Z [ft] - _ _ _ Temp [F] Detach From Diap Label _ - 0 17 0 - - -- - 0_ 2 1 _ -- -- -0 -- _ -- - -- o - - - - - -- o - - - -- -- — 0 - 7\7590 Rexburg Outpatient \7590 col.r3d] Page 1 RISA -3D Version 7 0,2 [C: \...\dean \My Documents\200 . Company May 7, 2008 Designer dmt 2:13 PM Job Number : 7590 Rexburg Outpatient Clinic Checked By: Member Primary Data - Label I Joint J Joint K Joint Rotate(deg) Section ?Shape , Type Design List Material Des gn Ru'es 1 _ a 1 2 col Column Tube A500 Gr 46 Typical Envelope Joint Reactions Joint X_[k] to _ Y ['t] Ic Z [k] Ic MX [k -ft] Ic MY [k -ft] Ic MZ [k -ft] Ic 1 _ 1 Max -1 1 25_.506 1 0 1 - 0 _ 1 0 1 17 1 2 min -1 1 4.355 2 0 1 0 1 0 1 17 1 3 Totals. max -1 1 26.506 1 - 0 1 4 min -1 1 4.355 2 0 1- Envelope Joint Displacements Joint X [in] Ic Y [inl Ic Z [in] Ic X Rotation ., Ic Y Rotation .- is Z Rotation [ Ic 1. 2 max 1 146 1 -_003 2- -- 0 1 0 1 0 1 - 0 2 - min 1.146 1 - _021 1- 0 - 1 0 1 0 -1 0 1 _ max 0 1 0 2 0 1— - - -.0 - - 1 0 1 0 1_ y 4 min 0 1 - 0 1 0 1 - 0 1 0 _ _1 0 1 Envelope Member Section Forces Member Sec Axial[k] Ic y Shear[k] Ic z Shear[k] Ic Torque[k -ft] Ic y -y Momen. Ic z -z Mcmen c 1 4 1 max 26.506 1 1_ 1 0 1 0 1 0 1 17 1 2 min 4.355 2 1 1 0- 1 _ 0 1 0 1 17 1 3 2 max 26.253 1 1 1 0 1 0 0 1 8.5 1 4 min 4.128 2 1 1 0 1 0 1 0 1 8.5 1 5 3 max 26 1 1 1 0 1 0 1 0 1 0 1 6 - min_ 3.9 2 1 1 0 1 0 1_ 0 1 0 1 Envelope Member Section Deflections Member Sec x [in] Ic y_[in] Ic z [inI c x Rotate [r., Ic (n) Uy Ratio Ic (n? Lrz Ratio Ic 1 4 1 max 0 1_ 0 1 0_ 1_ 0 1 NC 1 NC 1 2 min 0 1 0 1 0 1 0 1 NC 1 NC 1 3 2 Max -- 002 2 -.359 1 0 1_ 0 1 568.457 1 NC 1 4 _ min -.011 1 -,359 1 0 1 0 1 568.457 1 NC 1 5 3 max -.003 2 -1,146 1 0 1 0 1 178.068 1 NC 1 6 _ min -Ml 1 -1.146 1_ 0 1, 0 1 178.068 1 NC 1 Envelope A /SC ASD Steel Code Checks Member Shape Code C..._Loc[f _Ic Shear ... Loc[ft] Dir Ic Fa [ksi] Ft [ksi] _Fb_y -y [... Fb z -z [_ Cb "I- Cmy Cmz ASD Eqn 6 H1 1 4 HSS8X8X5 424 C 1 .012 0_ y 1 20492,_2'x6 - 30.36 _30.36 6 -2 RISA -3D Version 7.0.2 [C: \..\dean \My Documents \2007 \7590 Rexburg Outpatient \7590 col.r3d] Page 2 .Y .Z .x -26k 1k 2 Loads: LC 1, total Solution: Envelope Rexburg Outpatient Clinic dmt 7590 May 7, 2008 at 2 13 PM 7590 col rid '21 Company G & S Structural Engineers May r, 2008 Designer dmt Jcb Number 7590 Rexburg Outpatient Clinic Checked By: Sketch X 1.875 ft A w r 12 in m + q 4-4 o I LO M r Z d N 4.75 ft Details A X r -- a #4 @8.33 in ,3 w Ln L- #4@8.33 in Z #3 @6 ii C n ri c N C_ 4.75 ft Footing Elevation X Dir. Steel: 1.23 in (7,#4) Z Dir. Steel: 1.23 in (7 #4) Bottom Rebar Plan Geometry Materials and Criteria — Length 4.75 ft eX :0 in Gross Allow. Bearing 3000 psf Steel fy 60 ksi Width 4.75 ft eZ : 0 in Concrete Weight :145 pcf Minimum Steel :.0018 Thickness 12 in pX :12 in Concrete f'c 2.5 ksi Maximum Steel :.0075 Height 30 in pZ ' 12 in Design Ccde ACI 318 -02 Footing Top Bar Cover : 3.5 in Overturning Safety Factor A.5 Phi for Flexure 0.9 Footing Bottom Bar Cover :3.5 in Coefficient of Friction 0.3 Phi for Shear 0.75 Pedestal Longitudinal Bar Cover :1.5 in Passive Resistance of Soil 0 k Phi for Bearing : 0.65 Loads P (k) Vx (k) Vz (k) Mx (k -ft) Mz (k -ft) Overburden (psf) DL 27 1 - 17 300 3 RISAFoct Version 2.0 [Untitled.rft] Page 1 7� Company G & S Structural Engineers May 7, 2008 Designer dmt Checked By Job Number : 7590 Rexburg Outpatient Clinic Soil Bearin Categories and Factors Bearing Bu (k) Bearing Bu/ Bc ACI 9 -1 Description Cate_ and Factors Gross Allow.(psf) Max Bearing (psfj Max/Allowable Ratio Description gories 3000 2792.14 .931 ASCE 2.4.1 -1 1DL 3000 2792.14 (A) .931 ASCE 2.4.1 -2 1 DL +1 LL 3000 2792.14 (A) .931 ASCE 2.4.1 -3a 1DL +1WL 3000 2792.14 (A) .931 ASCE 2.4.1 -3b 1DL +.7EL 3000 2792.14 (A) .931 ASCE 2.4.1 -3c 1DL +.75LL +.75WL 3000 2792.14 (A) .931 ASCE 2.4.1 -3d 1 DL +.751-1- +.7EL 3000 1675.28 (A) .558 ASCE 2.4.1 -4 .6DL +1 WL 3000 1675.28 (A) 558 ASCE 2.4.1 -5 .6DL +.7E1- Footinq Flexure Design Bottom Bars Categories and Factors Bearing Bu (k) Bearing Bu/ Bc ACI 9 -1 Description Categories and Factors Mu -XX (k -ft) Z Dir As (in Mu -ZZ {k -ft} X Dir As (in ) ACI 9-1 1.4DL +1.7LL 19.223 .526 29.108 21.831 .599 ACI 9-2 1.05DL +1,275LL +1.275WL 14.417 .393 18.712 .512 ACI 9 -3 .9DL +1.3WL 12.357 16.477 .336 24.95 .686 IBC 16 -5 1.2DL +1 LL +1 EL 12.357 .45 .336 18.712 .512 IBC 16 -6 .9DL +1EL 11.131 .316 16.957 12.718 .481 Note: Overburden and footing self weight are included in the DL load case. 8.348 .237 Footiniq Shear Check Categories and Factors Bearing Bu (k) Bearing Bu/ Bc ACI 9 -1 1.4DL +1.7LL Two Way (Punching) Vc 133.65 k One Way (X Dir Cut) Vc 47.025 k One Way (Z Dir. Cut) Vc: 47.025 k .098 Punching X Dir Cut Z Dir. Cut Description Categories and Factors Vu(k) VU/ Vc Vu(k) Vu! Vc Vu(';') 19.783 V 561 c ACI 9 -1 1.4131- +1.71-1- 45.388 .453 34.041 12.986 9.739 .368 276 14.838 .421 ACI 9-2 1.05DL +1.275LL +1.275WL .34 29.178 8.348 .237 12.718 .361 ACI 9 -3 .9DL +1.3WL IBC 16 -5 1.2DL +1LL +1EL .291 38.904 .388 11.131 .316 16.957 12.718 .481 IBC 16 -6 .9DL +1 EL 29.178 .291 8.348 .237 .361 Note. Overburden and footing self weight are included in the DL load case. Concrete Bearing Check Vertical Loads Onl Bearing Bc 612 k Description Categories and Factors Bearing Bu (k) Bearing Bu/ Bc ACI 9 -1 1.4DL +1.7LL 51.944 ACI 9-2 1.05DL +1.275LL +1.275WL 38.958 .098 ACI 9 -3 +1.3WL 33.393 .084 IBC 16 -5 .9DL 1.2131-+1 LL +1 EL 44.523 .112 IBC 16 -6 .9DL +1EL 33.393 .084 Note. Overburden and footing self weight are included in the DL load case. Page 2 RISAFoot Version 2.0 [Untitled.rft] ,JI Project No. Date Designed By ✓�i 0 � eI/I; 0 �•? r I G&S Structural Engineers Sheet _ 0 I-V& 7 -x IY/O G&S Structural Engineers Sheet _ 0 K) WoodWorks' i r) a nq i lbs. osf. or Dif ) t COMPANY I PROJECT May 7 2208 08 10' woodplybearn Design Check Calculation Sheet Size- 7 0 S r L MAXIMUM REACTIONS (Ibs) and BEARING LENGTHS (in) : 0' 4 -6' Lumber n-ply, D.Fir-L, No.2, 2x12", 2-Plys Self-weight of 8.02 1p'f included in loads. Lateral support: top= at supports, bottom= at supports. Annlv-,is v-­ Allowable Stress (psi) and Deflection (in) using INDS 2005: ADDITIONAL DATA: S 3 L e C I L a 3„_ 0, 1-d! r. DESIGN NOTES: i Please verify that the default deflection limits are appropriate for your application 2 Sawn lumoer bending members shall be laterally supported according to the provisions of NDS Clause 4.4 1 3 BUILT-UP BEAMS it is assumed that each ply is a single continuous member (that is, no butt joints are present) fastened together securely at intervals not exceeding 4 times the depth and that each ply is equally top - loaded Where beams are side - loader, special tastering details may he required, WoodWorks�" COMPANY I PROJECT May 7. 2008 0813 Wplyioearn Design Check Calculation Sheet Size 7.0 I r)a n-q I Ids. DSf. or Of I - LVL n-ply, 1.8E, 2600Fb, 1-314x9-112", 2-Plys Self-weight of 9 58 pif included in leads. Lateral support: top= at supports, bottom= at supports. Analysis vs. Allowable Stress (psi) and Deflection (in) using INDS 2005: ADDITIONAL DATA: L -'r. L C 7 1 DESIGN NOTES: I Please verifv that the default deflection limits are appropriate for your application r final member design contact 2 SCL-BEAMS (Structural Composite Lumber) the attached SCL selection is for preliminary design only Fo I your local SCL manufacturer 3 Size factors vary from one manufacturer to another for SCL materials They can be changed in lied the database editcr 1 4. BUILT-UP SCL-BEAMS contact manufacturer for connection details when loads are not app equally to al' PlYs' �' S COMPANY WoodWorks""' r nA nQ 1 the ncf or nlf 1 PROJECT May 7- 2008 08:15 1 Iv!plybeam Design Check Calculation Sheet Sizer 7 0 MAXIMUM REACTIONS (lbs) and BEARING LENGTHS (in) : 0 10 -6't LVL n -ply, 1.8E, 2600Fb, 1- 314x11 -718 ", 2 -Plys Self- weight of 11.98 plf included in loads Lateral support: top= at supports bottom= at supports, DESIGN NOTES: 1 Please verify that the default deflection limits are appropriate for your application 2. SCL -BEAMS (Structural Composite Lumber) the attached SCL selection is for preliminary design only. For final member design contact your local SCL manufacturer. 3 Size factors vary from one manufacturer to another for SCL materials They can be changed in the database editor 4 BUILT -UP SCL- BEAMS: contact manufacturer for connection details when Icacs are not applied equally to all plys _ 1 t . MAXIMUM REACTIONS (lbs) and BEARING LENGTHS (in) : 0 10 -6't LVL n -ply, 1.8E, 2600Fb, 1- 314x11 -718 ", 2 -Plys Self- weight of 11.98 plf included in loads Lateral support: top= at supports bottom= at supports, DESIGN NOTES: 1 Please verify that the default deflection limits are appropriate for your application 2. SCL -BEAMS (Structural Composite Lumber) the attached SCL selection is for preliminary design only. For final member design contact your local SCL manufacturer. 3 Size factors vary from one manufacturer to another for SCL materials They can be changed in the database editor 4 BUILT -UP SCL- BEAMS: contact manufacturer for connection details when Icacs are not applied equally to all plys _ 1 a) us p CD i3 Ln a Ca m N N (b ` r r r M N N V O W Q) r C Q1 U C O LO * O to O M U') N O Cn co t~ O M O O co O C M N N V' co co M (O O O U) N � * * * O O Cl) O O Ln O C V U O O LO O O N y 0 (n m M O N N co Cl) V IT 00 a) r 3 > T to = N E O * * 0 0 M _ O O (J) Cb O O CO O f- co r N O (7) N N Cn V �7 O I I O I I U O O . p Ln Ln o Ln o 0 0 0 CD ° t0 6j U a M N �- cr CO O M M CO O I� tO O O t` t` N r 0 C O V Q O r X CL) m CD '- r Z * to O O Cn n O O O II N C� D W to N N N 0 co r- (D Cn Q a) Cn Co M to to to CO r - r .- .- N N 0 O 0 0 a c = U * CD o Ln o 00 Ln C) U-) CD > L z OM r- CO N p M O m - 76 O > Q co (� LO a) O O _T N �. (() 0 �7 O O l!) O O v J > V Lo L �' r O c CO V N r O O -O �Q O fl@ O N Lli p . N N M U- U C - 0 (1) m Q C > J O N O U a C '1J -0 CZ Z LO to O p p' N 0 w w f` C O L) M CC) O. N N c0 1- r' O N O N O Cl) 0) O Cn 00 3 N CO .N LO — O U O N @ N o CO 0 O C O +- N LO 0 0 �n O. r o ° 0) 0 (D M N O O O Cp M tf) O M �Y : (D t 0 t` O) L] — N r (T r- C Q 11 w E N C O LT O O N > d 0 t0 N M C :3 Z O O LO CD 0 O' O Cn C p E C U? CV N r co CT N r rn M to Cn O (D O _ to O N LL Q (n rn J d) 0 r N M r- 0 CO 0 C L tU Z o 0 0 o ° °o ° I.! o E O. s N 011 L O —° N @ E q �- O L - 0 'O N r O co ; M CN O CD O U O '� C ql� Z c cM w cU°�3m30� O E O N LL C (t7 U N N rn o Q V) 0- 0- O CCp D ` " O p �N (D 00 N Q '-p �CO Q - O N ` CO to U U I�i t o 3�� xtn xr N M x� NN X N X Nr xp N xM NO Cn 2 D N N N -C ca a< O II co M II N I M N CY) N -0 M m u- u " U- LL 0 <L I Z �- N M v tlj c0 t` co Pro:ect No. Date Project Designed By 7 Z_ " L , �, ez- C y! Sheet G&S Structural Engineers DESIGN NOTES: 1 Please verify that the default deflection limits are appropr ate for your application 2 BUILT-UP COLUMNS nailed or bolted built-up columns shall confcrm to the prov sions of NDS Clause 15 3 7,1 ANY 7C0MP COMPANY PROJECT WoodWorks" May 3, 2008 0137' ply Design Check Calculation Sheet I Sizer 7 0 LOADS Ibs, psf, or plf L n, I MAXIMUM REACTIONS (lbs): 13' Lumber n-ply, D.Fir-L, No.2, 2x6", 3-Plys Pinned base: Loadface = wicth(b), Built-up Self-weight of 5 88 plf included in loads fastener: nails Ke x Lb: 1.00 x 0 OC= 0.00 [ft], Ke x Ldi 1 00 x 13 00= 13 00 [ft], Repetitive factor applied where permitted (refer to crline help): Analysis vs Allowable Stress (psi) and Deflection (in) using NDS 2005: ADDITIONAL DATA: L n ca DESIGN NOTES: 1 Please verify that the default deflection limits are appropr ate for your application 2 BUILT-UP COLUMNS nailed or bolted built-up columns shall confcrm to the prov sions of NDS Clause 15 3 7,1 WoodWorks i n A r112 i I hq n-qf nr nif ) : COMPANY I PROJECT May 8, 2008 0938 plVC01 Design Check Calculation Sheet Sizer 7 -0 .......... Lc :1 _4 MAXIMUM REACTIONS (lbs): ----- ------ C' Lumber n-ply, D.Fir-L, No.2, 2x6", 5-Plys Self-weight of 9.8 pif included in loads: Finned base, Loadface widtn(b), B fastener nails Ke x Lb 1 00 x 0.00= 0 00 [ft], Ke x Ld 1 00 x 13.00= 13,00 [ft]. Repetitive facto; applied where permitted (refer to online help) #### WARNING Nailed B c olumns should not exceed 4 plys Analysis vs. Allowable Stress (psi) and Deflection (in) using NDS 2005: ADDITIONAL DATA: a ed S DESIGN NOTES: 1 Please verify that the default deflection limits are appropriate for Your apolicatw. 2 BUILT-UP COLUMNS nailed or bolted built-up columns shall conform to the provisions of NOS Clause 15.3 -7, 1 COMPANY 1 PROJECT W dWorks' M 7 2008 1251 wallstud 1 Design Check Calculation Sheet Sizer 7.0 I n A r*14Z 1 lh n , ,f nr nif 1 o MAXIMUM REACTIONS (ibs): z Lumber Stud, D.Fir-L, No.2, 2x6" Spaced at 16" c!c: Self-weight of 1 96 plf included in loads, Pinned base; Loacface = width(b) Ke x Lb 1 00 x 0 00= C 00 tft] Ke x '-d 1 :0 x 12 CO= 1200 [ft] Lateral support top = Lb bct*Low = L l Repetitive fac applied where oerm,tted ( refer to onxie heIP). DESIGN NOTES: 1 Please verify that the default deflection limits are appropriate for your application -/,3 S C n 4 MAXIMUM REACTIONS (ibs): z Lumber Stud, D.Fir-L, No.2, 2x6" Spaced at 16" c!c: Self-weight of 1 96 plf included in loads, Pinned base; Loacface = width(b) Ke x Lb 1 00 x 0 00= C 00 tft] Ke x '-d 1 :0 x 12 CO= 1200 [ft] Lateral support top = Lb bct*Low = L l Repetitive fac applied where oerm,tted ( refer to onxie heIP). DESIGN NOTES: 1 Please verify that the default deflection limits are appropriate for your application -/,3 WoodWq11r.k:s - -4 - -if % : COMPANY I PROJECT May 7, 2008 12:57 wallstud Design Check Calculation Sheet Scer 7.0 MAXIMUM REACTIONS (lbs): a' Lumber Stud, D-Fir-L, No.2, W" Spaced at 16" c;c, Self-weight of 2.E8 pif included in loads, Pinned base, Loadface = width(o) Ke x Lb 1 00 x 0 oo= 0 00 [ft], Ke x Ld. 1 Co x 18 oo= 18.00 [ft], Lateral support: top = Lb Inctton• - Lb Repetitive factor. applied where permitted (refer to online help), DESIGN NOTES: 1 Please verify that the default deflection limits are appropriate fcr your application. WoodWor s , COMPANY I PROJECT May 8 2CC8 09 -471 wallstud Design Check Calculation Sheet Sizer 7 C - ...-f .. -if 1 +-G46- MAXIMUM REACTIONS (lbs): o — Lumber Stud, D.Fir -L, SS, 1- 3/4x5 -1/2" Spaced at 16" c,'c Self- weight of 2.29 pif included In loads. Pinned base Loadface = width(b;: Ke x Lb: 1.00 x 0.00= O.CO [ft :: Ke x Lc 1 00 x 18.00= 18.00 [ft], Lateral support: top = Lb, bottom - LL: Repetitive factor. applied where permitted (refer to online help/: This section FAILS the design check WARNING: This section violates the following design criteria: Deflection WARNING this CUSTOM SIZE is not in the database. Refer to online help Analvcic vs- Allnwable Stress (psi) and Deflection (in) using NOS 2005 : ADDITIONAL DATA: DESIGN NOTES: 1 Please verify that the cefault deflection limits are appropriate for your application. —/. A. C WoodWorks"' 1— ..cf — r.If 1 : COMPANY I PROJECT May 8. 2008 09.481 wallstud Design Check Calculation Sheet Sizer 7.0 a7 d 7-- ' X � MAXIMUM REACTIONS (lbs): 01 Lumber Stud, D.Fir-L, SS, 1-3/4x5-1/2" Spaced at 16" c/c self-weight of 22 pif included in loads Pinned base: Loadface = width(b). Ke x Lb: 1 x 0 .00= 0,C0 [ft], Ke x Ld '-00 x 18 00= '8.00 [ft], Lateral suppor*, top = Lb, bottom = LL Repetitive factor applied where permitted (refer to online help) WARNING: this CUSTOM SIZE is not in the database Refer to online help 1—:1 —A r)-fl.nflnn finli —i— Nn.q 2005 ADDITIONAL DATA: 1,61 Project /, /7,,/ Project No. - Designed By T I 4� 4 Date Sheet elp G&S Structural Engineers X �,e �,; °rt ��_��• y .�� ti -may 31� X Sheet elp G&S Structural Engineers Company G & S Structural Engineers May - 7, 2008 Designer dmt Job Number 7590 Rexburg Outpatient Clinic Checked By. Sketch X w Al2 inp 4 H 4 m a Z � - D 1 ft H 0 Details X #4 @5 in Z #3 @6 in N 4a Ln 1 _ °t Controlling Z direction steel requires the following placement: Region 1 (starts at A) 3 in Steel: .03 in #4 @NA) Region 2 (middle) 12 in Steel: .26 in #4 @12 in) Region 3 (ends at D) 3 in Steel: .03 in #4 @NA) Bottom Rebar Plan Geometrv. Materials and Criteria C CD — U — G � � a Ln o m U Footing Elevation Length 1 ft eX : 0 in Gross Allow. Bearing :3000 psf Steel fy 60 ksi Width 1.5 ft eZ 0 in Concrete Weight :145 pcf Minimum Steel ..0018 Thickness :10 in pX :8 in Concrete fc 2.5 ksi Maximum Steel .0075 Height 48 in pZ 12 in Design Code ACI 318 -02 Footing Top Bar Cover :3.5 in Footing Bottom Bar Cover 3.5 in Pedestal Longitudinal Bar Cover :1.5 in Loads Overturnrng Safety Factor 1.5 Phi for Flexure 0.9 Coefficient of Friction 0.3 Phi for Shear 0.75 Passive Resistance of Soil 0 k Phi for Bearing 0.65 P (k) Vx (k) Vz (k) DL 1.3 LL 2.3 Mx (k -ft) Mz (k -ft) Overburden (psf) 300 RISAFoot Version 2.0 [Untitled.rft] Page 1 e. / Company G & S Structural Engineers May 7, 2008 Designer dmt Job Number 7590 Rexburg Outpatient Clinic Checked By Soil Bearin Description Categories and Factors Gross Allow (psf) Max Bearing (psf) MaxlAllowable Ratio ASCE 2.4.1 -1 1DL 3000 1411.94 (A) .471 ASCE 2.4.1 -2 1 DL +1 LL 3000 2945.28 (A) .982 ASCE 2.4.1 -3a 10L+1WL 3000 1411.94 (A) .471 ASCE 2.4.1 -3b 1DL +.7EL 3000 1411.94 (A) .471 ASCE 2.4.1 -3c 1 DL +.75LL +.75WL 3000 2561.94 (A) .854 ASCE 2.4.1 -3d 1DL +.75LL +.7EL 3000 2561.94 (A) .854 ASCE 2.4.1 -4 .6DL +lWL 3000 847.167 (A) .282 ASCE 2.4.1 -5 .6DL +.7EL 3000 847.167 (A) .282 Footing Flexure Design (Bottom Bars) Description Categories and Factors Mu -XX (k -ft) Z Dir As (in Mu -ZZ (k -ft) X Dir As (in` ) ACI 9 -1 1.4DL +1.7LL 8.59385e -7 I05559e -8 .398 .01 "- ACI 9 -2 1.050L +1.275LL +1.275WL 6.44539e -7 2.29169e -8 .298 .011 ACI 9-3 .9DL +1.3WL 2.38266e -7 8.47167e -9 .11 .004 IBC 16 -5 1.2DL +ILL +l EL 6.05188e -7 2.15178e -8 .28 .01 IBC 16 -6 .9DL +1 EL 2.38266e -7 8.47167e -9 .11 .004 Note: Overburden and footing self weight are included in the DL load case. Footing Shear Check Two Way (Punching; Vc: NA One Way (X Dir. Cut) Vc 11.25 k One Way (Z Dir. Cut) Vc: 7.5 k Punching X Dir Cut Z Dir Cut Description Categories and Factors Vu(k) Vul Vc Vu(k) Vu/ Vc Vu(k) Vu/ Vc ACI 9-1 1.4DL +1.7LL NA NA .003 0 .003 0 ACI 9-2 1.05DL +1.275LL +1.275WL NA NA .003 0 .003 0 ACI 9-3 .9DL +1.3WL NA NA .000953063 0 .000953063 0 IBC 16 -5 1.2DL +1 LL +1 EL NA NA .002 0 .002 0 IBC 16 -6 .9DL +1 EL NA NA .000953063 0 .000953063 0 Note: Overburden and footing self weight are included in the DL load case Concrete Bearing Check (Vertical Loads Only) Bearing Bc 206.125 k Description Categories and Factors Bearing Bu (k) Bearing Bu/ Bc ACI 9 -1 1.4DL +1.7LL 6.875 .051 ACI 9 -2 1.05DL +1.275LL +1.275WL 5.156 .038 ACI 9 -3 .9DL +1.3WL 1.906 .014 IBC 16 -5 1.20L +1 LL +1 EL 4.841 .036 IBC 16 -6 .9DL +l EL 1.906 .014 Note: Overburden and footing self weight are included in the DL load case. RISAFoct Version 2 C [Untitled.rft] Page 2 Company G & S Structural Engineers May 7, 2008 Designer dmt Job Number 7590 Rexburg Outpatient Clinic Checked By:_ Sketch X wAl2 ins q �d w `° .. a Z co N D _ 1 ft o Details B -- x i #4 @5 in Z #3 @6 in i a co w � N - 6 - --: to _ O 1 ft Controlling Z direction steel requires the following placement: Footing Elevation Region 1 (starts at A): 6 in Steel .07 in (1 #4 @NA) Region 2 (middle): 12 in Steel: .29 in #4 @12 in) Region 3 (ends at D): 6 in Steel: .07 in #4 @NA) Bottom Rebar Plan Geometrv. Materials and Criteria Length 1 ft eX :0 in Gross Allow. Bearing :3000 psf Steel fy 60 ksi Width 2 ft eZ :0 in Concrete Weight :145 pcf Minimum Steel :.0018 Thickness 10 in pX 8 in Concrete f'c 2.5 ksi Maximum Steel .0075 Height 48 in pZ :12 in Design Code ACI 318 -02 Footing Top Bar Cover . 3.5 in Overturning Safety Factor 1.5 Phi for Flexure 0.9 Footing Bottom Bar Cover 3.5 in Coefficient of Friction 0.3 Phi for Shear 0.75 Pedestal Longitudinal Bar Cover 1.5 in Passive Resistance of Soil 0 k Phi for Bearing : 0.65 Loads P (k) Vx (k) Vz (k) Mx (k -ft) Mz (k -ft) Overburden (psf) DL 1.5 300 LL 3.4 _ - RISAFcot Version 2.0 [Untitled.rft] Page 1 Company G & S Structural Engineers May 7, 2008 Designer dmt Job Number 7590 Rexburg Outpatient Clinic Checked By Soil Bearin Description Categories and Factors Gross Allow.(psf) Max Bearing (psf) Max /Allowable Ratio ASCE 2.4.1 -1 1DL 3000 1264 (A) .421 ASCE 2.4.1 -2 1 DL +1 LL 3000 2964.17 (A) •988 ASCE 2.4.1 -3a 1 DL +1 WL 3000 1264.17 (A) .421 ASCE 2.4,1 -3b 1DL +.7EL 3000 1264.17 (A) .421 ASCE 2.4.1 -3c 1DL +.75LL +.75WL 3000 2539.17 (A) .846 ASCE 2.4.1 -3d 1DL +.75LL +.7EL 3000 2539.17 (A) .846 ASCE 2.4.1 -4 .60L +1WL 3000 758.5 (A) .253 ASCE 2.4.1 -5 .6DL +.7EL 3000 758,5 (A) .253 Footing Flexure Design (Bottom Bars) Description Categories and Factors Mu -XX (k -ft) Z Dir As (in Mu -ZZ (k -ft) X Dir A7(in ACI 9-1 1.4DL +1.7LL 1.16496e -6 4.14207c -8 1.036 ACI 9-2 1.05DL +1.275LL +1.275WL 8.73719e -7 3.10656e -8 .777 •028 ACI 9 -3 .9DL +1.3WL 2.84438e -7 1.01133e -8 .253 .009 IBC 16 -5 1.2DL +ILL +1EL 8.0425e -7 2.85956e -8 .715 .026 IBC 16 -6 .9DL +1 EL 2.84438e -7 1.01133e -8 .253 .009 Note: Overburden and footing self weight are included in the DL load case. Footing Shear Check Two Way (Punching) Vc. NA One Way (X Dir_ Cut) Vc 15 k One Way (Z Dir_ Cut) Vc: 7.5 k Punching X Dir. Cut Z Dir Cut Description Categories and Factors Vu(k) Vu/ Vc Vu(k) Vu/ Vc Vu(k) Vu/ Vc ACI 9-1 1.4DL +1.7LL NA NA .005 0 0 .68 .121 ACI 9 -2 1.050L +1.275_ LL +1.275WL NA NA .003 .51 .091 ACI 9-3 .9DL +1.3WL NA NA NA .001 0 0 .166 .029 .469 .083 IBC 16 -5 1.2DL +1 LL +1 EL NA NA NA .003 0 .166 .029 IBC 16 -6 .9DL +lEL .001 Note: Overburden and footing self weight are included in the DL load case C oncrete Bearing Check (Vertical Loads Only) Bearing Bc 206.125 k Description Categories and Factors Bearing Bu (k)_ Bearing Bu/ Bc ACI 9 -1 1.4DL +1.7LL 9.32 ACI 9 -2 1.05DL +1.275LL +1.275WL 6.99 5 2 005 ACI 9 -3 .90L +1.3WL 2.276 .017 IBC 16 -5 1.2DL +1LL +1EL 6.434 .048 IBC 16 -6 .9DL +1 EL 2.276 .017 Note. Overburden and footing seif weight are included in the DL load case. Page 2 RISAFcot Version 2.0 [Untitled rft] 4 • Company G & S Structural Engineers May 7, 2008 Designer dmt Job Number 7590 Rexburg Outpatient Clinic Checked By: Sketch X .5 ft 12 in B w a Ii w W c N N Z D 2 ft 0 Details V #4@8.5 in i a� #4@8.5 in t,a 2 ft X Dir. Steel: .43 in` (3, #4) Z Dir. Steel: .43 in (3 #4) Bottom Rebar Plan Z X #3 @6 in Footing Elevation Geometry, Materials and Criteria q Length 2 ft eX :0 in H Steel fy 60 ksi W Concrete Weight :145 pcf Minimum Steel c Thickness 10 in pX :12 in Concrete fc 2.5 ksi Maximum Steel :.0075 Height 48 in pZ :12 in Design Code ACI 318 -02 ,, Footing Top Bar Cover 3.5 in Overturning Safety Factor .1.5 Phi for Flexure 0 Footing Bottom Bar Cover 3.5 in Coefficient of Friction 0.3 H 0.75 0.65 Pedestal Longitudinai Bar Cover :1.5 in Passive Resistance of Soil : 0 k Phi for Bearing . Footing Elevation Geometry, Materials and Criteria Length 2 ft eX :0 in Gross Allow. Bearing :3000 psf Steel fy 60 ksi Width 2 ft eZ :0 in Concrete Weight :145 pcf Minimum Steel .0018 Thickness 10 in pX :12 in Concrete fc 2.5 ksi Maximum Steel :.0075 Height 48 in pZ :12 in Design Code ACI 318 -02 Footing Top Bar Cover 3.5 in Overturning Safety Factor .1.5 Phi for Flexure 0.9 Footing Bottom Bar Cover 3.5 in Coefficient of Friction 0.3 Phi for Shear 0.75 0.65 Pedestal Longitudinai Bar Cover :1.5 in Passive Resistance of Soil : 0 k Phi for Bearing . Loads P (k) Vx (k) Vz (k) Mx (k -ft) Mz (k -ft) Overburden (psf) - 300 DL 4 LL 6 _ ... ...... ........ . Page 1 RISAFoot Version 2.0 [Untitled.rft] i Company G & S Structural Engineers May 7 , 2008 Designer dmt Job Numbe 7590 Rexburg Outpatient Clinic Checked By. Soil Bearin Description Categories and Factors Gross A!low.(psf) Max Bearing (psf) Max /Allowable Ratio ASCE 2.4.1 -1 1DL 3000 1490.83 (A) .497 ASCE 2.4.1 -2 1 DL +1 LL 3000 2990.83 (A) .997 ASCE 2.4.1 -3a 1DL +1WL 3000 1490.83 (A) .497 ASCE 2.4.1 -3b 1DL +.7EL 3000 1490.83 (A) .497 ASCE 2.4.1 -3c 1DL +.75LL +.75WL 3000 2615.83 (A) .872 ASCE 2.4.1 -3d 1 DL +.75LL +.7EL 3000 2615.83 (A) .872 ASCE 2.4.1 -4 .6DL +lWL 3000 894.5 (A) .298 ASCE 2.4.1 -5 .6DL +.7EL 3000 894.5 (A) .298 Footing Flexure Design (Bottom Bars) Description Categories and Factors Mu -XX (k -ft) Z Dir As (in Mu -ZZ (k -ft) X Dir As (in` ACI 9 -1 1.4DL +1.7LL 1.159 .041 1.159 .0 i ACI 9 -2 1.05DL +1.275LL +1.275WL .869 .031 .869 .031 ACI 9 -3 .9DL +1.3WL .335 .012 .335 .012 IBC 16 -5 1.2DL +1 LL +1 EL .822 .029 .822 .029 IBC 16 -6 .9DL +1 EL .335 .012 .335 .012 Note Overburden and footing self weight are included in the DL load case. Footing Shear Check Two Way (Punching) Vc: NA One Way (X Dir. Cut) Vc 15 k One Way (Z Dir. Cut) Vc: 15 k Punching X Dir. Cut Z Dir. Cut Description Categories and Factors Vu(k) Vu/ Vc Vu(k) Vu/ Vc Vu(k) Vu/ Vc ACI 9-1 1.4DL +1.7LL NA NA .009 0 .009 0 ACI 9-2 1.05DL +1.275LL +1.275WL NA NA .007 0 .007 0 ACI +1.3WL NA NA .003 0 .003 0 _.9DL IBC 16 -5 1.2DL +ILL +l EL NA NA .007 0 .007 0 IBC 16 -6 .9DL +l EL NA NA .003 0 .003 0 Note: Overburden and footing self weight are included in the DL load case. Concrete Bearinq Check (Vertical Loads Only) Bearing Bc . 310.25 k Description Categories and Factors Bearing Bu (k) Bearing Bu/ Bc ACI 9 -1 1.4DL +1.7LL 18.549 .092 ACI 9-2 1.05DL +1.275LL +1.275WL 13.912 .069 ACI 9 -3 .90L +1.3WL 5.367 .027 IBC 16 -5 1.2DL +ILL +1 El 13.156 .065 IBC 16 -6 .9DL +1 EL 5.367 .027 Note. Overburden and footing self weight are included in the DL load case. Page 2 RISAFoct Version 2.0 [untitled.rft] i�s rV O 9 ull A z t co • 'ill rn iir O Z Z 00 (j) 0 M rq � O a O > > � a� > ii fi O z 13% (ss— (SS —(SS — 0 0 PLOT DATE: 5-22-02 C .. .. .. .. .. . . . . . . . . C) > Z A LEASE 5PAvOE FOR r7l DALE C. PETTY . . . . . . z SCALE: =240 r n r 0 M DRAWN BY. z 4 0 , r) x C-) > Z 0 2'70 RZXBLR&, IDAHO L;1iJI 4 rn C> rn ro TRW R 9 ull A z t co • 'ill rn iir O Z Z 00 (j) 0 M rq � O a O > > � a� > ii fi O z 13% (ss— (SS —(SS — 0 a ;0 PLOT DATE: 5-22-02 .. .. .. .. .. . . . . . . . . "PROJECT: > PROJECT No. 0207- -207 PLOT t A LEASE 5PAvOE FOR DALE C. PETTY . . . . . . z SCALE: =240 PLOPARTMENT Or LA50K n r JOHINY R. WATSON GARY D. RICHARDSON DRAWN BY. JOB NO: , RANDAli G. ASHCRAFT C-) > Z 0 2'70 RZXBLR&, IDAHO L;1iJI 4 RICHARD A. DMOIS A SSOCIATES C> rn TRW 6A DRAWM TITLE: -- Y OF REXBW c JOHN R. WATSON 1152 am lvm R"w M" eso > CHECKED BY. DATE: 511M PLAN ARCHITECTURE - ENGINEERING (M) 3W m rn '04 CONSTRUCTION MANAGEMENT Fax (206) 359-2zn C/) jp4N MAY