Loading...
HomeMy WebLinkAboutBP, CO & DOCS - 04-00251 - Parkside Townhomes - ClubhouseCITY OF REXBURG 4 0 7 7 INSPECTION CAR[ d ro m BUILDING I -J ISSUED TO: NAME: Parkside Plat B 04002 FQk THE CONSTRUCTION OF: Clubhouse Par kside .)p'I3 ADDRESS- 889 Parkside Dr GENERAL CONTRACTOR: Owner This permit is issued subject to the regulations contained in Building Code and Zoning Regulations of the City of Rexbug. It is specifically understood that this Permit does not allow any Variance to the regulations of the Cityof Rexburg or Zoning Codes unless specifically approved by the City Council and explained on the Building Permit Application as approved bythe Building Inspector. Date Approved issued By Building Inspector THIS PERMIT MUST BE PROMINANTLY DISPLAYED AT THE BUILDING SITE THE BUILDING MAY NOT BE OCCUPIED OR USED WITHOUT FIRST OBTAINING A CERTIFICATE OF OCCUPANCY 1) A complete setof a rod d d i - Date Approved I OTHER D ate improved � Fire &pertm ent Fines -� PLUMBING -- _ Date _pproved 1. Sewer Se rvi ce . Conn 2. Wate Se rvice Connt 3. R - - 4. Grou Rough -In 5. Final - W v W N m m N N G N N N Go D 1 VF a rawngs along with the permit must be kept No work shall be done on any pwt of For Inspections Call 359 - 3020 eKt. 341 on the premises during construction. the building beyond the point indicated Z ) The permit will become null and void In the event of any deviation from the in each successive inspection wthout NOTICE! 2l Hour NetiCe accepted drawings. approval. No structural framework of A C ERTIFICATE OF OCCU PANCY CAN NOT 3) No foundation, structural, electrical, nor plumbing work shall be concealed any underground workshall be covered BE ISSUED PRIOR TO FINAL. ELECTRICAL without approval & PLUMBING INSPECTION t n g ation ing' tio r�l ll a l k I 9. M ec h anica l OTHER D ate improved � Fire &pertm ent Fines -� PLUMBING -- _ Date _pproved 1. Sewer Se rvi ce . Conn 2. Wate Se rvice Connt 3. R - - 4. Grou Rough -In 5. Final - W v W N m m N N G N N N Go D 1 VF a rawngs along with the permit must be kept No work shall be done on any pwt of For Inspections Call 359 - 3020 eKt. 341 on the premises during construction. the building beyond the point indicated Z ) The permit will become null and void In the event of any deviation from the in each successive inspection wthout NOTICE! 2l Hour NetiCe accepted drawings. approval. No structural framework of A C ERTIFICATE OF OCCU PANCY CAN NOT 3) No foundation, structural, electrical, nor plumbing work shall be concealed any underground workshall be covered BE ISSUED PRIOR TO FINAL. ELECTRICAL without approval & PLUMBING INSPECTION ���BURC`s CITY °F CERTIFICATE OF OCCUPANCY REX �. America's Family Community Department of Community Development fHFD $' 19 E. Main St. / Rexburg, ID. 83440 Phone (208) 359 -3020 / Fax (208) 359 -3022 Building Permit No: Applicable Edition of Code: Site Address: Use and Occupancy: Type of Construction: Design Occupant Load: Sprinkler System Required: Name and Address of Owner: Contractor: Special Conditions: Occupancy. 0400251 International Building Code 2003 895 Freedom Ln Apartment Clubhouse Type V -N, Unprotected Clubhouse No Georgetown Development Inc 2230 N University Parkway Provo, UT 84604 Owner Assembly, less than 300, without a stage This Certificate, issued pursuant to the requirements of Section 109 of the International Building Code, certifies that, at the time time of issuance, this building or that portion of the building that vies inspected on the date listed vies found to be in compliance mith the requirements of the code for the group and division of occupancy and the use for Mich the proposed occupancy vies classified. Date C.O. Issued: January 20, 20 C.O Issued by: Building Official 5PM) There shall be no further change in the e)asting occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and approved said future changes. Water Department Nmrp State of Idaho Electrical Department Site A �• Name MOi 4g d. l L �3L _• City /State/Zip Telephone/Fax/Mobile CONTRACTOR Name IEOpl�ETASjil.) DEt/fi.. empA it Mailing Address 2 I1f !) =99-217 jo icy { S T91G '7 6- City/State/Zip Z0 —VD , L JJ R g6D4 012MMiW � �� a/ . M PROJECT INFORMATION DEPARTMENT APPROVAL Property Zone: Is existing use compatible with zoning, (screening parking, etc) When was this building last occupied A Architect/ Engineer Firm SDf tN MWJQ Z (, Plan Name CL }- aj5E T � Subdivision LUIV Lot Block C ircle One Residential ommerci Educational Government Remodel Other Circle One New House Addition/Remodel to House dew Commerc' ommercial Remodel Circle One Basemen on Finished / Unfinished Other: None/ Patio Carport/ Awning N/A Lot Square Footage— Lot Width ! g ! '� Garage Square Feet Number of Stories f Height of Building What will structure be used for: Home Home Business Apartment ommerci OtheI kh,nE f PaY- Main Level Square Feet qG 5 Upstairs Square Feet , Basement Square Fee Will there be an apartment? Total Estimated Building V Signature of Applicant If so, how many units '! Are you in a flood plain /{/ A �) ? j � Code Building Permit Fees Zone Building Type Commercial Building Plumbing bid Commercial Building HVAC bid Commercial Building Square footage (Parks, Fire, and Police) Plan Check Fees Plumbing Permit Fees Digging Permit Fees Water & Sewer Fees Front Footage Fee Impact Fees ' TOTAL $ Signature of Inspector Issued by � p Aiv x a o CITY OF REXBURG APPLICATION FOR PLUMBING PERMIT OWNER Name Address 5# A, Tel. x1.0772 Lot Blk. --/0 Add. PLUMBER Name WAlQ —,r &499a& Address Tel o 1 1 74o FEES Plumbing Permit • • • ................. $ Sewer Inspection .................... $ Inspection of Pipe ................... $ Inspection of Fixtures • • • ............. $ NATURE OF INSTALLATION Use Rough Plumbing Septic Tank Fixtures Water Piping Complete Sewer DESCRIPTION OF WORK Bath Tubs Urinal Showers Sink Trap Laundry Trays Water Heater Wash Basin Other Toilet Slop Sinks Kitchen Sinks Floor Drain Drinking Fountains Lawn Sprinklers Water Softeners Dish Washing Mach. Clothes Washer Received: Date By— INSPECTOR'S RECORD W W Rough Plumbing Sewer Other Finish Plumbing TOTAL $ E S INSP. NAME SUBCONTRACTOR LIST Excavation & Earthwork: ELI, y z/zs g Con crete: -6Q&,MQ V,QZ Masonry: X2A��71E� Roofing: —ILA QE Insulation: ton i c Drywall : �f�/�► 1�� -41 Painting: Rey �WX -rz - ,- PAS Floor Coverings: yc� Plumbing: rL�r Heating: Electrical Y - MC&7,,r Af c��'I r.• SPECIAL CONSTRUCTION (Manufacturer or Supplier) Roof Trusses: Floor / Ceiling Joists: Cabinets: A Siding /Exterior Trim: Other: EXISTING FENCE @— — TRASH RECEPTICAL FUTURE PHASE 3 S PATIO UTILITY DEDICATION Parkside Development, L.C., owner of the parcel of land which is shown upon the plat of Parkside plat B US HT�Y 20 R. 0, W. planned residential development consents to the preparation and recordation of this plat and hereby offers and conveys to all public utility agencies and their successors and assigns a permanent easement and right —of —way as shown by the areas marked "utility easement" "private drives" or "common areas" on the plat for the construction and maintenance of the subterranean electrical, telephone, natural gas, sewer and water lines and appurtenances, together with the right of access thereto. N N CLUBHOUSE /POOL 899 W. GEORGETOWN SQUARE NORTH AREA: 4,615 SO FT x Ld 3 20' S � S METER - LOCATION 5' CONC. WALK T S O FIRE HYDRANT E E— E DRAINAGE GEORGETOWN SQUAREWEST O (890 WEST) 6 3' ILVCATCH BASIN UP 21 I 30' LAJ N O Q �Z o w P W \ ° LLJ i i i i E DRAINAGE 24' Q Z� Q Z Z E— ^^ V DTI W RETENTION POND UNDE CATCH 8 °SIN I — 41 I I C 40 I PLANTER C vC ®� ko 6 �ko r IN �P.. 4 I Cn 0 0 Cn I W > Cqa i IF- DRAWN BY. N d om c v< Q a J n E iA F 4 1 I- M Lil �I RL SCALE: 1"=30' = 0 10 20 30 40 50 LiJ O N " Li.l (n M r IZ 1-1 70 °N U N d om c v< Q M J n E V Z men!!!- I- M Lil �I RL SCALE: 1"=30' = 0 10 20 30 40 50 39 38 i —> Z z CO US HWY 20 R. 0. W. NEW 6' CEDAR FENCE---, DRIVEWAY 1W.1171 ON I I I (k- a �mll LAWN l �mm al mmmmllm�ffi L.j Uf -cr C3 T IS SIMILAR TO PHASE 1 V) Zl- t— Li CLUBHOUSE LANDSCAPE PLAN " 11111111111 -1 PATIO F.M STREES @ 5'-0' O,C, SOUND/WINDBREAK X. Aik LAWN SNOW RETENTION - AREAS' GEORGETOWN SQUAREWEST (890 WEST) :D C2% Z L3 ce r ui L3 z LJ r F- LAJ 1-4 CD CD cl- - 1 III V) D 0 C L'i M D a- LLJ O =30' IR I 0 10 20 30 40 50 cq J m NN N LAWN C) � � � c) z M cl) 0 cv 0. DRAW BY: \ � �+. 1. �. �� \ } / J � "af �s1�,i- 3"175 f ry � ' W E I i 1 +ri �, y ✓_ +"�Y i� V J ��� �x� PE m N N Q 0 0 0 a z N ^ M w LLJ 0 m U N W E S I w W CIS o Q n SCALE: 1"=20' v � � O ko o U zu- W Q °o0 ko oom ~ �� V) F W ,-ZO �<� Z O ,y fl IILLJ r oa } _ MZ jr uj a V) a (� l � w> wwm� d a 0p tJ <D3 Of °zmaf o (� O J � O UO=V ow�a N Z ]F !�\ t��w M aw r M `'J 0w¢� lI j J <Mr Ofoar ¢�Z< omao < a V)�� 0 DRAWN BY: (nma< W () . o mwa JPH - x DATE: Q3 -U I) Hi /nz W CIS o Q n SCALE: 1"=20' - i �! �'60o kw�! GIE 0 1,wt 12/15/03 Val Christensen Building Official City of Rexberg P.O. Box 280 Rexberg, Idaho 83440 Dear Val, I have. reworked the drawings for the-Parkside, -Clubhouse, In answer to the deficiencies listed: I See sheet no. I for the site plan. Also included in the set is the over all site plan for all phases, and a purposed plan for phase 2. 2. The plans have been stamped and a set of stamped calculations: are included. 3. The manufacturer's certificates will be sent as soon as possible, when it is determined who they will be, per our phone conversation on 12/11/03. 4. See sheet numbers 2 & 8a for the I hr fire wall separation call out, and the construction of that wall. Also see sheet no. 2 for the door schedule naming those doors as I hr fire rated. 5. See sheet no. 6 for the location of the exit signs. 6. The truss details will be provided by the truss manufacture. As soon as it is determined who that will be. 7.&8. Please find the Com-Check compliance certificate attached. 9. 1 have attached a separate letter for the Fire Department, addressing their issues. If you have any other comments or questions please feel free to contact me at 801-374-077 Sincerely, Jim Hansen draftsman/designer Georgetown Development Inc. 2230 N. University Pkwy., Suite 7G Provo, UT 84604 Phone 374-0772 Fax 375-0502 4 U RG�O9Z Cil R s ,� ge`►SHEO P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone (208) 359 -3020 STATE OF IDAHO Fax (208) 359 -3022 e -mail rexburg@srv.net REXB UR G- MADISON COUNTY EMERGENCY SER VICES 26 NORTH CENTER STREET REXB URG, IDAHO 83440 208- 359 -3010 208 - 359 -3006 FAX 2000 International Fire Code Plan Date: 4 -03 -01 Plan Review Review Date: 12 -18-03 SECOND REVIEW Building Name: Building Address: UNKNOWN Stories: ONE Type of Construction: V -B Occupancy Classification: A -3 Existing Floor Area: N/A New Construction Floor Area: APPROXIMATELY 4,500 SQUARE FEET 1. Required Fire Flow (Appendix B): 1750 GPM/TWO HOURS Comments: FIRE FLOW MAY BE REDUCED IF STRUCTURE HAS AN APPROVED AUTOMATIC FIRE SUPPRESSION SYSTEM INSTALLED. 2. Water Supply (Section 508, Appendix C) Required: YES Fire Hydrant Location: THREE PROPOSED HYDRANTS Fire Hydrant Flows: UNKNOWN Fire Flow Test Location: N/A U Fire Flow Supplied By: N/A Other Approved Water Source: NONE Water Supply Acceptable: YES Fire Hydrant Location Acceptable: YES Water Supply Comments: UNKNOWN HYDRANT FLOW, PLEASE PROVIDE ENGINEERS CALCULATION FOR FLOWS. 3. Fire Apparatus Access Roads (Section 503, Appendix D) Required: YES Acceptable Width: X Length: X Surface: OK Complete Road Acceptable: YES Comments: NONE 4. Access Roads and Water Supply, including fire hydrants are required to be installed and made serviceable prior to and during time of construction (Section 501): Comments: IF NOT INSTALLED PRIOR TO CONSTRUCTION AND MADE OPERATIONAL, A STOP WORK ORDER WILL BE ISSUED. 5. Installation of portable fire extinguishers (Section 906) Required: YES Location shown: YES Type provided acceptable: YES Comments: NONE 6. Automatic fire extinguishing systems (Section 903) Required: NO Type of system being installed: NOT SHOWN Sprinkler system monitoring (Section 907) required: Comments: NONE 7. Standpipes (Section 905) required: NO Type required: Comments: 8. Ventilating hood and duct fire extinguisher system (Section 609) required: NO Y • y Type being provided: Automatic fuel shut -off required: Portable fire extinguisher shown: Comments: 9. Fire alarm systems (Section 907) required: YES Type of system required: Manual: Automatic: X Both: Type of system being provided: Manual: Automatic: Both: Components of system shown: Smoke Detectors: Heat Detectors: Manual Pull Station: Sounding Devices: Visual Devices: Door Holders: Duct Detectors: Flow Alarm: Sprinkler Valve Monitoring: Fire Alarm System Acceptable: NO, ADDITIONAL SMOKE DETECTORS ARE REQUIRED IN OCCUPANCY AS PER NFPA 72. PLEASE PROVIDE ADDITIONAL SMOKE DETECTORS IN CONVERSATIONIMEETING AREA. 10. Other corrections that are required by special occupancy or conditions: NONE Plans as submitted are acceptable: NO Plans checked by: CHRIS HUSKINSON Date: 12 -18 -03 Please furnish comments back to the plan reviewer in the following manner: Written Comments: X New Plans: X JIM - PLEASE PROVIDE HYDRANT CALCULATIONS AND ADDITIONAL SMOKE DETECTORS AND YOU SHOULD BE SET TO GO. CHRIS ( l i ly ([.lG 0 ex 0 lL// STATE OF IDAHO !/ www.ci.rexburg.id.us P.O. Box 280 12 North Center Street Rexburg, Idaho 83440 Phone(208)359 -3020 Fax(208)359 -3022 e -mail rexburg @ci.rexburg.id.us 10/10/2003 John Dester arks cre 1r: =ite7G Provo, UT 84604 Dear John, The energy code compliance documents that you provided me for the Rexburg, Idaho 'ieare for Spanish Fork Utah and are from an outdated software. Please provide a new checklist using COM Check (available at energycodes.com). Be sure to pick the 2000 IECC and Rexburg, Idaho from the drop down lists. If you have any questions, please give me a call at 359 -3020 ext. 324. Sincerely, Val Christensen Building Official WATER DESIGN, INC. - POOL CALCULATIONS BY: BEN P ROJECT: Parkside Recreation Rexberg, Idaho CHECKED: POOL CONTRACTOR: Aquatech Pools DATE: 9/27/04 JOB NO. 04 -150 Page 1 of 4 POOL SIZE: AREA: # OF SKIMMERS: Length (ft) 36 calculated 1 .537 5 Width (ft) 18 615 Qty: 2 Depth (ft) 3 to 4.5 to 3 Model: Pentair Bermuda NSF Approved PERIMETER: # OF INLETS: Adjustable calculated 7.083333 106.25 feet Use 8 13.28 feet c.c. Gross Volumes: Volume Calculation: Pool: 3833 Cu,F,t. Average Step Riser: 10.5 9.8 Inches 3800.7 ft x 7.48 = 28429 Gallons Bottom Step Riser: 10.5 9.8 Inches Less Fillets: = 0 Gallons Less Steps & Benches: 36.25 32.3 Cu. Ft. _ Net Volume = 28429 Gallons Less Fillets: 0 Gallons FLOW RATE & TURN -OVER: Min Flow Rate = 65 GPM Max Flow = 88 GPM 28429 GALS. = 59.22758 GPM 28429 GALS. =1 7.31 Hr. T.O. 8 HR.X 60 MIN. 65 GPM.X 60 MIN. FILTER: Type: Hi Rate Sand Qty: I Model: Pentair Triton TR -100C (30" dia) Filter Area (each filter): 4.91 Total Filter Area: 4.91 Filter Rate: 13.2 GPM /SF Min Flow 4.91 x 13 GPM/SF = 63.83 Min. 18 GPM /SF > Flow/Filter Area > 13 GPM /SF Max Flow 4.91 x 18 GPM /SF = 8838 Max SKIMMER FLOW: 65 GPM X 80% = 26 GPM per SKIMMER (25 GPM min - 55 GPM max) 2 SKIMMER INLET ORIFICE Dia.= (Q/47.16) ^1 /2 0.415 inch dia, Adjust inlets to Q = 65 GPM = 8.125 x')2= 13.28 7/16 " dia. 8 INLETS Head Loss thru Orifice (feet of loss) = 12.17 ft. MAIN DRAINS: # of Main Drains: = 2 Capacity at 1.57sec = 196 GPM /DRAIN Brand of Drains: = Hayward (velocity at max filter flow) Model # of Drains:= SP1031 -9" x 9" Square Use 2.5 " Line between Drains 5.75 ft /sec Open Area of Cover: = 42 Use 2.5 " Suction line to Pump 5.75 ft/sec FLOWMETER: BlueWhite Flow Meter Model: F30200P Sensor: N/A Flow Range for Flowmeter: CAPACITY (Range): 40 -150 GPM 65 gpm x,95 = 62 GPM FACE PIPING: = 2 in. diameter 65 gpm x 1.05 68 GPM Vel. in FacePiping: = 8.99 ft/sec (at max allowed filter rate) HEATER SIZING: Avg Day Temp (F): 70 UNDERWATER LIGHTING REQUIREMENTS: Indoor = Minimum 30 Lumens /SF Avg Night Temp (F): 70 Elevation Factor = EF Avg Temp (F): 70 Area 615 x 30 = 18450 Lumens Reqd EF: 1.25 Desired Pool Temp (F): 86 Outdoor = Area 0 x 15 = 0 Lumens Reqd (Surface Area x Constant x Temp Rise x Elev. = BTU/hr Req'd) Number of Lights 2 Size of Light 500W 615 x 15 x 16 x EF = 184,500 x Lumens per Light 10250 Model: Pentair PowerMax Size (BTU /hr): 400,000 = Total Lumens 20500 > 18450 Heat Time in Hours (with heater size given) = 9.5 Lum Provide > Lumens Reqd = So OK Heat Time in Hours at Max Load (with heater size given) = 17.6 LIGHT MODEL: U.L. Listed - 500Watt Pool Light WATER DESIGN, INC. - POOL CALCULATIONS Page 2 of 4 CHEMICAL FEED TYPE: Solid Feed OZONATOR (MFG): None Estimated Requirement: Model: n/a 28429 Gal./3333 = 8.53 # /Day or Gal./ Day Elec Reqmt: n/a CO2 FEED SYSTEM: USE (Model) : Bio -lab MA35 Sanitizer USE (Model) : n/a pH Model: None MAX. CAPACITY: 12.5 # /Day, Gal. /Day or ppm Elec Reqmt: n/a Max. Capacity > Estimated Requirement 12.46 >8.53 so OK Switch -over: n/a CHEMICAL CONTROLLER: AUTOMATIC LEVEL CONTROLLER: Model: None Model: None Elec Reqmt: n/a Elec Reqmt: n/a Sensing: n/a Sensor Reqd: n/a POOL CONTROL SYSTEM / TIMERS: POOL COVER: Model: None None Elec Reqmt: n/a VACUUM LINE: Options: n/a Size: 2 " dia. CULINARY LINE: 1 "dia. To Fill Funnel at suction side of pump BATHER LOAD: SANITARY FIXTURES REQUIRED: for depth < 5 ' 615 sq. ft. /(1 o sq. ft. /person) = 61.5 People Males: 30.5 Females: 30.5 for depth> 5' 0 sq. ft. /(24sq. ft./ person) = 0 People # of W.C.s 0 # of W.C.s 0 Total Bathers = 61 People # Showers 0 # Showers 0 Total Bathers / 2 = # of Each Gender = 30.5 /GENDER I# Lavatory 0 # Lavatory # Urinals 0 See spa Cales for Reqmt 0 # W.C.s / 9 Urinals > verify: BY: BEN PROJECT: Parkside Recreation Rexberg, Idaho CHECKED: POOL CONTRACTOR: Aquatech Pools PIPING HEAD LOSS ANALYSIS: DATE: 9/27/04 PAGE 3 of 4 JOB NO. 04 -150 LINE PIPE FITTINGS TOTALS Se ent Flow Size Velocit L/P 90 Ell Equiv. Len h 45 Equiv. Len th Tee- Branch Equw Len I,.F e- u Equiv. Length V alve Equiv. Length Fittings Total Total Equiv. Length HL /100' Total Head Losses Skimmer #1 26 2 2.66 36 3 9 2 1 5 1 17 0 0 0 0 54 90 1.41 1.27 Skimmer #2 0 2 0.00 0 0 0 0 0 0 0 0 0 0 0 0 j 0 0.00 j 0.00 Skim Junct 52 2.5 3.40 33 4 10 0 0 1 20 0 0 1 1.4 61.4 94.4 1.72 1.62 Return Junct 65 2.5 4.25 33 4 10 0 0 1 20 0 0 1 1.4 61.4 94.4 2.59 2.45 Main Drain 65 2.5 4.25 56 6 10 0 0 2 20 0 0 1 1.4 101.4 157.4 2.59 4.08 Face Piping 1 65 2 1 6.64 20 6 1 9 0 0 0 0 2 7 2 1.15 70.3 90.3 7.68 6.94 INLET LOOP ANALYSIS: T Total Flow 6 65 GPM 8.125 GPM Pipe E Equiv T Tee T Total (inch 9 90 L Lengt 4 45 E Equiv E Equiv E Equiv H Head Loss FT Inlet # F Flow e es) L Length E Ells h h F Fitting L Length L Length L Lenth p per 100 FT. L Loss R Running Loss 1 32.5 2 1 18 1 1 9 2 5 5 7 4 44 2 2.13 0 0.94 0 0.94 2 24.4 2 1 17 1 1 9 7 7 3 33 1 1.25 0 0.41 1 1.35 3 16.3 1.5 1 15 5 5 2 20 2 2.39 0 0.48 1 1.83 4 8.13 1.5 1 15 5 5 2 20 0 0.66 0 0.13 1 1.96 5 0 1.5 1 10 5 5 1 15 0 0.00 0 0.00 1 1.96 6 0 1.5 1 10 5 5 1 15 0 0.00 0 0.00 1 1.96 7 0 1.5 1 10 5 5 1 15 0 0.00 0 0.00 1 1.96 8 0 1.5 1 10 5 5 1 15 0 0.00 0 0.00 1 1.96 9 0 1.51 1 101 5 5 1 151 0 0.00 0 0.00 1 1.96 10 0 1 1.51 1 101 5 5 1 151 0 0.00 TOTAL DYNAMIC HEAD ANALYSIS: SUCTION SIDE OF PUMP: H HEAD LOSSES Skimmer #1 a Skimmer #2 0.00 Skimmer Line n/a Skimmer 1.00 Main Drain 4.08 H &L Strainer 0.00 PRESSURE SIDE OF PUMP: Filter 4.00 PAGE 4 of 4 JOB NO. 04 -150 PUMP SELECTION: USE Pentair Whisperflo WFE -4 H.P. 1 220V Single Phase @ 65 GPM - 68 Ft TDH Available Backwash Valve 8.00 Dirty Filter (8.7PSI) 19.00 Heater 7.00 Return Line 2.45 Face Piping 6.94 Inlet Loop /Branches 196 Inlet Orifice 12.17 TOTAL (TDH): 66.59 ,. IF PAGE 4 of 4 JOB NO. 04 -150 PUMP SELECTION: USE Pentair Whisperflo WFE -4 H.P. 1 220V Single Phase @ 65 GPM - 68 Ft TDH Available Backwash Valve 8.00 Dirty Filter (8.7PSI) 19.00 Heater 7.00 Return Line 2.45 Face Piping 6.94 Inlet Loop /Branches 196 Inlet Orifice 12.17 TOTAL (TDH): 66.59 ,. IF ,. IF AQUATECH 8435 South 255 W. Sandy, LIT 84070 (801) 569 -0120 To: City of Rexburg Building D ept. 12 No, Center Street Rexburg, ID 83440 We are sending you: below: XX Concept Drawings Prints XX Plans Copy of Proposal Letter Change Order Sample Construction Agreement Submittals XX Other Copies 2 Date 10/4/04 No. 5 I Description 1 Pool and spa plans and specifications 1 4 Pool engineering data 1 3 Spa engineering data These are transmitted as check For Approval XX For Your Use As Requested For Review & Comment FOR BIDS DUE Resubmit Submit Return Other As we discussed on the phone, here are the pool and spa plans to be added to your plan file for the above referenced building permit. If you need additional information, or if we can be of further assistance, please let us know. Thanks Received by: Date: CC: Signed: _7im Pk/7y LETTER OF TRANSMITTAL Date: 10/4/04 1 Job No Attn: Kathy Winter Re: Clubhouse Parkside - Permit #04 00251 QAttached Approved as Submitted Approved as Noted Return Corrections Shop Drawings 9/29/00 cmb -- ?K -C ! L.11 amo u, T up - 7" c,aous toe wuo— I I L I I I I I' j ,r 9 iA L 1. II I I; 24 Ila � I QI � i N ri l �. ?54603 E 2" P -NX >I • N 0 / O ^� 876 838 O O a �N UG 1 /p -'C( �...._... 0 _.__/ - - — -- � i '('R o� 7.2 1 #2 -AL Xt.P � uGj• - — — — — — 2 852 PARKSIDE DR,I g I N � N I I O o • ; D I N ' a` l O A 154 780 :GC ; a $ G "350- ; G 4-208 I I ?ss50 - - - - - - - _ _ _ Y s "' ' D - _ �4MA #I -AL x E ? s 47o1 1 -2" PVC ®� 1 -2" PVC �2" PdC 3 CL 0: a 0a C N W N ,Verify fusf3astze W E :27 X26 25 X24 23; ,22 :.2 1 ... ?Q:19. : ..:..:...:.. .. _ ...... , a ' ........... I....... I N I -- ?K -C ! L.11 amo u, T up - 7" c,aous toe wuo— I I L I I I I I' j ,r 9 iA L 1. II I I; 24 Ila � I QI � i N ri l �. ?54603 E 2" P -NX >I a, 0 o W 0 CL 0 N O U Ck: O a CO �w ✓� O O o D a` O O o WO 000 O x y CL 0: a a, 0 o W 0 CL .- N U Ck: O CO �w ✓� O O D o Y 0 O ) 33 O x y 0a C N W N W E U Structural Review for: Parkside Clubhouse Location: Rexburg, Idaho Job #: 2003 -805 Engineered by: DWP Coder 2000 IBC Loadings -8.8 Ground Snow Load: 4,8 Elevation= 4926 ft A d - - -. 4.5 S 63'. Po 43 Ps 507 psf Roof Snow Load: -7.3 Ct= 11' Roof Exposure Ce 0, 9 Full 1 _1i Roof Pitch = 8/12 Pp 351 psf Roof Dead Load: DL= 1 15. psf Floor Loadings: Dead Load= 10. psf Live Load = 100 psf 40 psf Wind Loadina• Basic Wind Speed V = 90, mph Directionality Factor K = 085 Importance Factor l = _.. 1 Exposure Category = B Enclosure Classification = Enclosed Mean Height of roof = 20 it Horizontal Loads: (Values fnr Rnnf Heinht = 3n' and Frnnew. R1 Transverse Longitudinal PenWend= 14.4 Pw fiend= 128 Pmof end = 9.9 P.n intend,= 8.5 Pvrwl intend, = 11.5 -15.4 Proof Interior= 7.9 -8.8 Vertical Loads: (Values for Roof Heiaht = 30' and Exposure B) Transverse Longitudinal - .:. Longitudinal P.11 end= 12.8 Pwind roof end = 5.6 Pwind roof end = -15.4 Pleeromend= -8.8 Pin roof end= -8.8 Pwiid roof interior 4,8 Pwlnd roof intend, -10.7 Plee roof imenor = -7 5 Pin roof interior = -68 Povemang and= -65 Povednang end= -23,.1 Pove,nana imedor = -7.3 Povern.nq interior = 48.4 Height(Exposure Adjustment: 1.00 Horizontal Loads: (Adiusted Values) Transverse. Longitudinal - .:. Pavan end= 14.R P.11 end= 12.8 Proof entl 9 9..9 P.11 interior = 8.5 Pwall interior =' 11..5 -15.4 Proof interior = 7.9 -8..8 Vertical Loads: (Adiusted Valueel Transverse Longitudinal Pwind roof end= 5.6 Pwndroofend -15.4 Pin roof end -8..8 Plee roof end -8.8 l roof intendr 4 . 3 Pwind roof intenor -10.7 Pies and imeuor' -7..5 Pleeroorirdenor= -6.8 Povemang end 4.5 Povemang end= -23..1 Poyernang interior= -7.3 Pavernang interior= -18.4 -1- Loadings (continued) Seismic Loading: Spectral Accel (short period) S = 05 Spectral Accel (1 sec. period) S, = 015 F = ...... 1.4 F„ = 2 SMs — 0.7 SM1 = 0.3 S — 04667 Sol = 02 Seismic Design Category =. D R= 6 Structural Sheathing R = 2 Sheetrock R= __8 -: Steel Frames Height of bldg. h„ (ft) = 25` Bldg.. Period Coeff C = 002 Fundamental Period T. (sea) = 0 2236 4th Floor Ceiling Height h = 0 ft 3rd Floor Ceiling Height h 3 = 0 f 2nd Floor Ceiling Height h = 0. ft 1st Floor Ceiling Height h, =. 10 ft —2— PREFACE THIS ENGINEERING REPORT IS VALID ONLY FOR THE FOLLOWING PLAN AND LOCATION: Parkside Clubhouse Building 10 Phase 2 Parkside subdivision in Rexburg, Idaho THIS ENGINEERING PACKET IS TO BE USED ONLY ONCE FOR THE ABOVE MENTIONED LOCATION AND IS NOT TO BE COPIED OR REPRODUCED WITHOUT WRITTEN CONSENT OF LEI CONSULTING ENGINEERS. A SOIL BEARING PRESSURE OF 1500 PSF IS ASSUMED SINCE NO SOILS REPORT WAS AVAILABLE. IF THE VALUES AND ASSUMPTIONS STATED IN THIS REPORT ARE INCORRECT, OR IF CHANGES IN THE FIELD ARE NOTICED WHICH ARE DIFFERENT FROM THOSE STATED IN THIS REPORT, THE ENGINEER MUST BE NOTIFIED IN ORDER FOR THE NECESSARY CORRECTIONS TO BE MADE. IF THERE EXISTS ANY DISCREPANCY BETWEEN THE CALCULATIONS AND THE DRAWINGS, THESE CALCULATIONS SHALL SUPERSEDE. THE ROOF TRUSS SUPPLIER SHALL ENGINEER THE ROOF TRUSS SYSTEM. THEREFORE, THE ENGINEERING OF THE ROOF TRUSSES IS NOT CONTAINED IN THIS REPORT. THIS ENGINEERING REPORT DEALS ONLY WITH THE STRUCTURAL PARTS OF THIS BUILDING AND DOES NOT PROVIDE LIABILITY TO THE NON - STRUCTURAL PARTS THE OWNER AND /OR BUILDER IS RESPONSIBLE TO SEE THAT PRODUCTS ARE APPLIED CORRECTLY AND IN ACCORDANCE WITH MANUFACTURERS' SPECIFICATIONS AND THE REQUIREMENTS OF THE UNIFORM BUILDING CODE. SEE LVL MANUFACTURER'S SPECIFICATION GUIDE FOR ALL CONSTRUCTION INFORMATION ON MULTIPLE PLY BEAMS, NOTCHES, HOLES, BEARING ETC. IF PLANS ARE STAMPED IN CONJUNCTION WITH THIS ENGINEERING PACKET, CERTIFICATION PERTAINS ONLY TO THE STRUCTURAL ELEMENTS OF THE PLANS„ -3- Summary Floor Joists: FJ1: 9 1/2" TJI /150 @ 16" o.c. as noted on plans FJ2: Not Used 3/4" T &G flooring to be nailed with 8d nails @ 6" o.c. edge, 12" o.c. field Deck Joists: DJ1: 2x10 DF -L #2 @ 16" o „c. as noted on plans Roof. Trusses by others 7/16” roof sheathing to be nailed with 8d nails @ 6" o.c. edge, 12" o „a. field Overbuild to be 2” x 8" Timber @ 24" o „c. Other: All bearing headers to be (2) 2x10 (DF L #2 or better) unless noted otherwise All exterior sheathing to be Shear Wall #1 unless noted otherwise All glulam beams are to be 24F -V4 unless noted otherwise Strap end lengths for shear walls (see also Simpson Coiled strap specs.): CS16 = 14” CMST14 = 34" CMSTC16 = 25" Beams Beam Number Size Type RB1 2 2 x 10 Timber RB2 2 91/2" Microllam RB3 2 117/8" Microllam RB4 2 2 x 10 Timber RB5 1 3 1/8" x 9,, Glulam RB6 2 91/2" Microllam MB1 1 5 1/8" x 12" Glulam MB2 1 3 1/8" x 9" Glulam MB3 1 3 1/8" x 9,, Glulam -4 ■ �j�� °�/ Floor Joists TJ- B " e 6 r. 7603 00a io 9 1/2" TJ! ®IPt'O(TM) -150 @ 16" O/c User .2 121120031:49:231oM Pagel Engine Versim1.10.3 THIS PRODUCT MEETS OR EXCEEDS THE SET DESIGN CONTROLS FOR THE APPLICATION AND LOADS LISTED 7❑, , 2 ❑ Product Diagram is Conceptual., LOADS: Analysis is for a Joist Member. Primary Load Group - Residential - Living Areas (psf): 100 0 Live at 100 % duration, 10.0 Dead SUPPORTS: Maximum Design - Input Bearing Shear (Ibs) Width Length 1 Stud wall 350" 2, 25" 2 Stud wall 3.50" 2.25" Vertical Reactions (Ibs) Detail Other Live /Dead /Uplif rrotal 767 / 77 / 0 / 843 A3: Rim Board 1 Ply 1 1/4" x 9 1/2" 0 8E TJ- Strand Rim Board® 767 / 77 / 0 / 843 A3: Rim Board 1 Ply 1 1/4" x 9 1/2" 0 8E TJ- Strand Rim Board® -See TJ SPECIFIER'S / BUILDERS GUIDE for detail(s): A3: Rim Board DESIGN CONTROLS: - Deflection Criteria: STANDARD(LL:U480,TL:L1240). - Allowable moment was increased for repetitive member usage. - Deflection analysis is based on composite action with single layer of 19/32" Panels (20" Span Rating) GLUED & NAILED wood decking. - Bracing(Lu): All compression edges (top and bottom) must be braced at 77" o/c unless detailed otherwise Proper attachment and positioning of lateral bracing is required to achieve member stability . TJ -Pro RATING SYSTEM -The TJ -Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 19/32" Panels (20" Span Rating) decking.. The controlling span is supported by walls. Additional considerations for this rating include: Ceiling - None.. A structural analysis of the deck has not been performed by the program. Comparison Value: 1.32 - ADDITIONAL NOTES: - IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). TJ warrants the sizing of its products by this software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user This output has not been reviewed by a TJ Associate. -Not all products are readily available. Check with your supplier or TJ technical representative for product availability -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.. - Allowable Stress Design methodology was used for Building Code IBC analyzing the TJ Distribution product listed above. PROJECT INFORMATION: 2003 -805 Parkside Clubhouse Copyright C 2003 by Tres Joist, a Weyerhaeuser Business TJI0 and TJ -Beam& are registered trademarks of Trus Joist. e -I Joist^, pro^ and TJ -Pro° are trademarks of True loiet u : \structural \T11 \2003 \2003 -805 Parkside Clubhouse. sms OPERATOR INFORMATION: David Ploeger LEI Consulting Engineers and Surveyors, Inc. 3302 N, Main St Spanish Fork, Utah 84660 Phone 801-798-0555 Fax :801- 798 -9393 dave @lei -eng com _F Maximum Design Control Control Location Shear (Ibs) 813 801 1120 Passed (71 %) Lt, end Span 1 under Floor loading Vertical Reaction (Ibs) 813 813 1016 Passed (80 %) Bearing 2 under Floor loading Moment (Ft -Lbs) 2252 2252 2839 Passed (79 %) MID Span 1 under Floor loading Live Load Defl (in) 0 265 0.277 Passed (L/501). MID Span 1 under Floor loading Total Load Defl (in) 0 292 0.554. Passed (L/456) MID Span 1 under Floor loading TJPro 51 30 Passed Span - Deflection Criteria: STANDARD(LL:U480,TL:L1240). - Allowable moment was increased for repetitive member usage. - Deflection analysis is based on composite action with single layer of 19/32" Panels (20" Span Rating) GLUED & NAILED wood decking. - Bracing(Lu): All compression edges (top and bottom) must be braced at 77" o/c unless detailed otherwise Proper attachment and positioning of lateral bracing is required to achieve member stability . TJ -Pro RATING SYSTEM -The TJ -Pro Rating System value provides additional floor performance information and is based on a GLUED & NAILED 19/32" Panels (20" Span Rating) decking.. The controlling span is supported by walls. Additional considerations for this rating include: Ceiling - None.. A structural analysis of the deck has not been performed by the program. Comparison Value: 1.32 - ADDITIONAL NOTES: - IMPORTANT! The analysis presented is output from software developed by Trus Joist (TJ). TJ warrants the sizing of its products by this software will be accomplished in accordance with TJ product design criteria and code accepted design values. The specific product application, input design loads, and stated dimensions have been provided by the software user This output has not been reviewed by a TJ Associate. -Not all products are readily available. Check with your supplier or TJ technical representative for product availability -THIS ANALYSIS FOR TRUS JOIST PRODUCTS ONLY! PRODUCT SUBSTITUTION VOIDS THIS ANALYSIS.. - Allowable Stress Design methodology was used for Building Code IBC analyzing the TJ Distribution product listed above. PROJECT INFORMATION: 2003 -805 Parkside Clubhouse Copyright C 2003 by Tres Joist, a Weyerhaeuser Business TJI0 and TJ -Beam& are registered trademarks of Trus Joist. e -I Joist^, pro^ and TJ -Pro° are trademarks of True loiet u : \structural \T11 \2003 \2003 -805 Parkside Clubhouse. sms OPERATOR INFORMATION: David Ploeger LEI Consulting Engineers and Surveyors, Inc. 3302 N, Main St Spanish Fork, Utah 84660 Phone 801-798-0555 Fax :801- 798 -9393 dave @lei -eng com _F Shingles Roof Pitch= Angle= Cs= Increase for DrifWalley= Effective snow load (psf)= Length (ft)= Trib. Area mar Trib. Area flaaf wroof (plf) = (w /reduction) wfloor(P10 _ Point Load (lb)= a (ft)= b (ft)= Add. uniform load (plf)= WT IWO = Left Reaction (lb)= Right Reaction (lb)= Vmaa (Ib)= Location of Mmax (ft)= Mmaa (ftib)= S (Timber) (in')= Sraq (Glu -lam) (in')= S raq (1.3E T- strand) (IF?)= S (Microllam) (in')= S (Parallam) (ir?)= Beam Type (t,g,ts,m,p) Size Factor= Smq it (in)= b (in)= I (in S (in - )= E (psi)= Fv (psQ= f (psi)= Location of Max Deflection= Deflection (in)= Allowable Deflection (in)= RBI R52 8 8 33.7 33.7 0.970 0.970 1.000 1.000 34 34 5 6 21 25 0 0. 937 1115 0 0 2.5 3' 2.5 3 937 1115 2342 3346 2342 3346 2342 3346 2.5 3.0 2927 5019 39 67 15 25 21 35 14 23 12 21 t m 1.000 1.000 39 23 9.25 9.5 3 3.5 197.9 250.1 42.8 52.6 Section OK Section OK 1600000 1800000 180 285 127 151 Shear OK Shear OK 2.50 3.00'. 0.042 0.072 0.333 0.400 Deflection OK Deflection OK RB3 RB4 RB5 RB8 MB1' 8 '. 8 8 81. 33.7 33.7 33.7 33.7 0.970 0.970 0.970 0.970 1.000'. -1.000 1.000 1.000. 34 34 34 34 1237.5 134 - 937 803 1238 - 669 2810 4015 6497 o 669 2810 4015 6497 669 2810 4015 6497 5.0 3.0 5.0 5.3 1673 4216 10037 17054 22 56 134 227 8 ,21 50 85 m 12 30. 71 120 8 19 46 79 W 7 17 42 71 t 9 m 9''.. 1.000 1.000 1.000 - 1.000 22 21 AR sr; 42.8 42.2 52.6 Section OK Section OK Section OK 1600000 1800000 1800000 180 123.0 Section OK 1800000 190 36 150 181 158 Shear OK Shear OK- Shear OK Shear OK 5.00 '. , 3.00 5.00 5.25- 0.095 0.080 0.401 0.255 0.667 0.400 - 0.667 0.350 Deflection OK Deflection OK Deflection OK Deflection OK 190 285 Multi- Loaded Beam[ 2000 International Building Code (97 NDS) 1 Ver: 6, 00.2 , By: David W Ploeger, , LEI Consulting Engineers on: 12 -01 -2003: 1:27:16 PM Project: 2003 -805 - Location: RB3 Summary: ( 2) 1,75 IN x 11.875 IN x 9 0 FT / 1.9E Microllam - Trus Joist - MacMillan Section Adequate By: 0.3% Controlling Factor. Section Modulus / Depth Required 11.85 In * Laminations are to be fully connected to provide uniform transfer of loads to all members Center Span Deflections: Dead Load: DLD- Center= 0.07 IN Live Load: LLD- Center- 016 IN = U696 Total Load: TLD- Center= 0.22 IN = U483 Center Span Left End Reactions (Support A): Live Load: LL- Rxn -A= 2345 LB Dead Load: DL- Rxn -A= 1063 LB Total Load: TL- Rxn -A= 3408 LB Bearing Length Required (Beam only, support capacity not checked): BL -A= 1.30 IN Center Span Right End Reactions (Support B): Live Load: LL- Rxn -B= 5058 LB Dead Load: DL- Rxn -B= 2226 LB Total Load: TL- Rxn -B= 7283 LB Bearing Length Required (Beam only, support capacity not checked): BL -B= 2.77 IN Beam Data: Center Span Length: L2= 90 FT Center Span Unbraced Lenqth -Top of Beam: Lu2 -Top= 60 FT Center Span Unbraced Length -Bottom of Beam: Lu2- Bottom= 9.0 FT Live Load Duration Factor: Cd= 1.00 Live Load Deflect. Criteria: U 360 Total Load Deflect Criteria: U 240 Center Span Loading: Uniform Load: Live Load: wL -2= 0 PLF Dead Load: wD -2= 0 PLF Beam Self Weight: BSW= 13 PLF Total Load: wT -2= 13 PLF Point Load 1 Live Load: PL1 -2= 4778 LB Dead Load: PD1 -2= 2047 LB Location (From left end of span): X1 -2= 6.0 FT Trapezoidal Load 1 Left Live Load: TRL- Left -1 -2= 105 PLF Left Dead Load: TRD- Left -1 -2= 45 PLF Right Live Load: TRL- Riqht -1 -2= 105 PLF Right Dead Load: TRD- Right -1 -2= 45 PLF Load Start: A -1 -2= 00 FT Load End: B -1 -2= 60 FT Load Length: C -1 -2= 60 FT Trapezoidal Load 2 Left Live Load: TRL- Left -2 -2= 665 PLF Left Dead Load: TRD- Left -2 -2= 285 PLF Right Live Load: TRL- Right -2 -2= 665 PLF Right Dead Load: TRD- Right -2 -2= 285 PLF Load Start: A -2 -2= 6,0 FT Load End: B -2 -2= 9.0 FT Load Length: C -2 -2= 30 FT Properties For: 1.9E Microllam- Trus Joist - MacMillan Bending Stress: Fb= 2600 PSI Shear Stress: Fv= 285 PSI Modulus of Elasticity: E= 1900000 PSI Stress Perpendicular to Grain: Fc_rerp= 750 PSI Adjusted Properties Fb' (Tension): Fb'= 2545 PSI Adjustment Factors: Cd =1,00 CI=O 98 Cf =1,00 Fv': Fv'= 285 PSI Adjustment Factors: Cd =1 00 Design Requirements: Controlling Moment: M= 17385 FT -LB 6 03 Ft from left support of span 2 (Center Span) Critical moment created by combining all dead loads and live loads on span(s) 2 Controlling Shear: V= 6417 LB At a distance d from right support of span 2 (Center Span) Critical shear created by combining all dead loads and live loads on span(s) 2 Comparisons With Required Sections: Section Modulus (Moment): Sreq= 81.97 IN3 S= 82,26 IN3 Area (Shear): Areq= 33,77 IN2 A= 41.56 IN2 Moment of Inertia (Deflection): Ireq= 252.51 IN4 1= 488.41 IN4 -7- Shingles W MB2 MB3 Roof Pitch= 8 8' Angle= 33.7 33.7 Cs= 0.970 0.970 Increase for Drift/Valley= 1.000 ` 1.000 Effective snow load (psf)= 34 34 Length (ft)= 8 +' 11.5 Trib. Area r „r 0 0' Trib. Area floor 9 = 3.5 w = (w /reduction) 0 0 Wfi. r(PIO = - - 450 175 Point Load (lb)= a (ft)= 4 - 5.75' b (ft)= 4 Add. uniform load (plf)= wT(Plf) = 450 175 Left Reaction (lb)= 1800 1006 Right Reaction (lb)= 1800 1006 V...(lb)= - 1800 1006 Location of M,,,,, (ft)= 4.0 5.8 M...(ftlb)= 3600 2893 S (Timber) (in')= 48 39 S r , q (Glu -lam) (ir?)= 18 14 S r , q (1.3E Tstrand) (in')= 25 20 S r , q (Microllam) (in')= 17 13 S r , q (Parallam)(In')= 15 - 12 Beam Type (t,g,ts,m,P) 9 ',, 9 Size Factor= 1.000 1.000 Sreq 18 14 d (in)= 9 ',, 9'. b (in)= 3.125 ':3.125. (in 189.8 - 189.8 S (in')= 42.2 42.2 Section OK Section OK E (psi)= 1800000 1800000 F,.(psi)= 190 190 fv (Psi)= 96 54 Shear OK Shear OK Location of Max Deflection= 4.00 '.. '.. 5.75'.. Deflection (in)= 0.121 0.202 Allowable Deflection (in)= 0.267 0.383 - Deflection OK Deflection OK Shear. Waus I seismic I Wind Front panel 3.5 ':218 272 55 (382 +6865 4550 25400': panel 3.5 1218 272 TAROO...d TAMIL -end panel 4.5 280 350 96 70 panel 5 '.280 350 panel s 5 280 350 SWS SWS.I.M, Sheathing panel 280 350 319 77 panel 280 350 Use SW2 Use SW1 Transverse panel 280 350 panel 280 350 panel 10 280 350 panel 11 '.280 350 panel 12 280 350 panel 13 280 350 panel 14 280 350 panel 15 ; 280 350 panel 16 280 350 ASW= 21.5 Use SW2 Use STHD14 /14RJ holdowns each side of panel as noted on plans Shear Walls I Seismic I Wind Rear panel 4.5 252 315 9 348 290 ::8043 4550 25400', 9 panel 3 168 210 9 TAROOaandTAWOn Ond 9 '9 panel 3 .168 9 210 2299 96 '70 0 0 panel 3 .168 0 210 0 0 Sheathing V panel 5 panel 4,5 252 1280 315 350 0 SWS Wn SWS 277 57 0 Use SW1 Use SW1 panel 7 Transverse w panel 8 ', 280 350 280 350 panel 9 0 280 350 0 0 panel 10 4 280 350 0 0 panel 11 4 280 350 panel 12 3 :280 350 panel 13 280 350 panel 14 280 350 panel 15 280 350 panel 16 -280 350 ASW= 29 Use SW2 Use STHD14 /14RJ holdowns each side of panel as noted on plans Sei smic rMa., SWS p R F 0.108 110 1.000 6 2371 Sei rmaxi SWS p, R F 0.054 82 1.000 6 2371 1659 1659 V SWS DL h h' Uplift 6865 319 100 9 r9 2699 100 9 19 2699 100 9 9 2649 230 9 '9 2299 230 9 9 2299 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 i0 0 0 0 c a 0 C7 c t Check V SWS DL. h h' Uplift 8043 277 100 10;10 2548 100 10`10 2623 100 10 :10 2623 100 10 r 10 2623 100 10'10 2548 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 i0 0 c `u 0 c cn 0 Rear of weight S panel 1 7.5 '.. 280 350 327 348 `:332 7978 4550 50800 . conversation panel 7 '. 280 350 TAROOr -end TAWall.and TAROOf -and rooms panel :280 350 4125 0 '98 112 panel 4 280 350 panel 8 280 350 Sheathing panel 5 panel 280 - 280 350 350 Sheathing panel 5 panel SWSwlnd SWSamsmi 272 272 280 116 Transverse panel 7 panel `. 280 280 350 350 101 Transverse Use SW1 Use SW1 187 280 panel 6,25 : 280 350 Use SW1 Use SW1 panel ,'280 panel 10 7.75 : 280 350 panel 10 panel 11 280 350 panel 12 280 350 350 panel 13 '. 280 350 280 350 panel 14 '..280 350 ;.. 280 350 panel 15 1280 350 panel 14 280 350 panel 16 ! 280 350 panel 15 ..4280 350 ASW= 28.5 Use SW2 panel 16 '280 Use STHD14114RJ holdowns each side of panel as noted on plans Shear Walls Seismic I Wind Length SWt SW2 TAROOMM. TAW.1 Left panel 4.67 262 327 350 250 7757 4550'.. 50800.: panel 6280 350 TAROOf -and TAW -end panel 3 4125 238 298 112 70 panel 8 280 350 Sheathing panel 5 panel 3.5 3.5 218 218 272 272 SWSwmd SWSaeismi 236 101 Transverse panel 7 panel 3 1 : 187 280 233 350 Use SW1 Use SW1 panel ,'280 350 panel 10 280 350 panel 11 '+ 280 350 panel 12 280 350 panel 13 ;.. 280 350 panel 14 280 350 panel 15 ..4280 350 panel 16 '280 350 ASW= 32.92 Use SW1 Use STHD14114RJ holdowns each side of panel as noted on plans rmaxi SWS pi ' R Fz Vfinal 0.095 166 1.000 6 4741 3319 Seismic rmaxl SWS pi R Fx Vfinal 0.074 144 1.000 6 4741 3319 c 0 t7 9 c d 0 0 v c 3 280 236 Check t DL h 9 1657 9 1714 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D 0 D 0• 10 1819 10 1666 10 1868 9 1721 9 1946 9 1946 9 1971 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Right panels 11.5 280 350 ':10 677 0 250 .7757 4550 50800'. 230 panel 2 7.5 280 350 0 0 entl TA wall en panel3 0 0 panel3. 12.25 280 350 0 0 70 0 0 - panel fl28O 350 0 0 [TA;RI 0 0 Sheathing panels panel 280 280 350 350 0 0 Sws nd SWSselsmi 254 109 Transverse panel 7 panel .280 280 350 350 Use SW1 Use SW1 panel 9 11.5 f 280 350 panel 10 - 280 350 panel 11 !280 280 350 - panel 12 '280 280 350 panel 13 280 350 panel 14 280 350 panel 15 280 350 panel 16 1.280 280 350 ASW= 30.5 Use SW2 Use STHD14 /14RJ holdowns each each side of panel as noted on plans Shear Walls _ Seismic I Wind Right of Pool panel 1 5 280 350 ':10 677 0 216 !2911 4550',. 254001 230 pane12 6 280 350 0 0 TARow -and TAwan -end 0 0 panel3. 12.25 280 350 0 0 0 84 0 0 panel 4 0 0 280 350 0 0 0 0 Sheathing panels panel6 : 280 280 350 350 0 0 SWS SWS 125 71 Longitudinal v panel 7 panel8 ": :280 280 350 350 Use SW1 Use SW1 panel 9 J 280 350 pane110 280 350 panelll 280 350 - panel12 '280 350 panel 13 280 350 panel 14 280 350 panell5 280 350 panel16 280 350 ASW= 23.25 Use SW1 Use STHD14 /14RJ holdowns each side of panel as noted on plans 0.124 155 1.000 6 4741 3319 rmax , SWS p R F„ Vflnal 0.227 102 1.000 6 2371 1659 c 0 v c k c 0 c7 c 254 9 1714 9 1914 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. Check uplift V SWS DL h h' Uplift 2911 125 230 10 ':10 677 230 10 ':10 562 230 10 10 -157 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Right - pool equip panel 1 16 .. 280 350 0 45 ,1010 4550: 5000 0.625 29 1.500 6 467 490 Seismic 0 panel 280 350 TARoot -end TAww -end Ai Wii rM., SWS p R F, Vfnai Front & Rear of panel 1 panel 280 350 0 49 ,6 963 4550 5000 y 0.833 39 1.500 6 467 490 :0 panel ! 280 350 280 350 TARom -end TAwan -end 0 panel 280 350 SWS., SWSaeiamm 280 350 Sheathing VI panel 6 280 350 63 31 panel !280 panel 7 280 350 Use SW'I Use SW1 Longitudinal 7 panel 280 350 SWS, SWSsetsmm panel 9 - 280 350 280 350 82 41 panel 10 '= 280 350 panel - 280 350 panel 11 280 350 Transverse 71y panel 280 panel 12 280 350 panel 9 panel 13 '.280 280 350 panel 14 280 350 280 350 panel 15 280 350 panel 11 280 350 panel 16 : 280 350 panel 12 280 ASW= 16 Use SW1 panel 13 No Uplift 280 350 Shear Walls Uplift Length Seismic - Wind 0 Seismic 0 0 SWl SW2 TARo,i, TAwaii-int. V. Ai Wii rM., SWS p R F, Vfnai Front & Rear of panel 1 12 280 350. 4 ,6 963 4550 5000 y 0.833 39 1.500 6 467 490 :0 pool equip. panel 2 1 280 350 TARom -end TAwan -end 0 0 panel 3 - 280 350 28 42 panel !280 350 panel 280 350 SWS, SWSsetsmm Sheathing 7 panel 6 280 350 82 41 panel - 280 350 Use SW1 Use SW1 Transverse 71y panel 280 350 panel 9 280 350 panel 10 280 350 panel 11 280 350 panel 12 280 350 panel 13 280 350 w E panel 14 280 350 i panel 15 :280 350 0 panel 16 280 350 c ASW= 12...... Use SW1 Use STHD14 /14RJ holdowns each side of panel as noted on plans 63 B -295 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Check uplift V SWS DL In h' Uplift 983 82 100 8 ''.8 55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 :0 0 0 0 0 0 0 0 0 0 N Shear. Waus I seismic I Wind Front panel 3.5 ':218 272 55 (382 +6865 4550 25400': panel 3.5 1218 272 TAROO...d TAMIL -end panel 4.5 280 350 96 70 panel 5 '.280 350 panel s 5 280 350 SWS SWS.I.M, Sheathing panel 280 350 319 77 panel 280 350 Use SW2 Use SW1 Transverse panel 280 350 panel 280 350 panel 10 280 350 panel 11 '.280 350 panel 12 280 350 panel 13 280 350 panel 14 280 350 panel 15 ; 280 350 panel 16 280 350 ASW= 21.5 Use SW2 Use STHD14 /14RJ holdowns each side of panel as noted on plans Shear Walls I Seismic I Wind Rear panel 4.5 252 315 9 348 290 ::8043 4550 25400', 9 panel 3 168 210 9 TAROOaandTAWOn Ond 9 '9 panel 3 .168 9 210 2299 96 '70 0 0 panel 3 .168 0 210 0 0 Sheathing V panel 5 panel 4,5 252 1280 315 350 0 SWS Wn SWS 277 57 0 Use SW1 Use SW1 panel 7 Transverse w panel 8 ', 280 350 280 350 panel 9 0 280 350 0 0 panel 10 4 280 350 0 0 panel 11 4 280 350 panel 12 3 :280 350 panel 13 280 350 panel 14 280 350 panel 15 280 350 panel 16 -280 350 ASW= 29 Use SW2 Use STHD14 /14RJ holdowns each side of panel as noted on plans Sei smic rMa., SWS p R F 0.108 110 1.000 6 2371 Sei rmaxi SWS p, R F 0.054 82 1.000 6 2371 1659 1659 V SWS DL h h' Uplift 6865 319 100 9 r9 2699 100 9 19 2699 100 9 9 2649 230 9 '9 2299 230 9 9 2299 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 i0 0 0 0 c a 0 C7 c t Check V SWS DL. h h' Uplift 8043 277 100 10;10 2548 100 10`10 2623 100 10 :10 2623 100 10 r 10 2623 100 10'10 2548 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 i0 0 c `u 0 c cn 0 Rear of weight S panel 1 7.5 '.. 280 350 327 348 `:332 7978 4550 50800 . conversation panel 7 '. 280 350 TAROOr -end TAWall.and TAROOf -and rooms panel :280 350 4125 0 '98 112 panel 4 280 350 panel 8 280 350 Sheathing panel 5 panel 280 - 280 350 350 Sheathing panel 5 panel SWSwlnd SWSamsmi 272 272 280 116 Transverse panel 7 panel `. 280 280 350 350 101 Transverse Use SW1 Use SW1 187 280 panel 6,25 : 280 350 Use SW1 Use SW1 panel ,'280 panel 10 7.75 : 280 350 panel 10 panel 11 280 350 panel 12 280 350 350 panel 13 '. 280 350 280 350 panel 14 '..280 350 ;.. 280 350 panel 15 1280 350 panel 14 280 350 panel 16 ! 280 350 panel 15 ..4280 350 ASW= 28.5 Use SW2 panel 16 '280 Use STHD14114RJ holdowns each side of panel as noted on plans Shear Walls Seismic I Wind Length SWt SW2 TAROOMM. TAW.1 Left panel 4.67 262 327 350 250 7757 4550'.. 50800.: panel 6280 350 TAROOf -and TAW -end panel 3 4125 238 298 112 70 panel 8 280 350 Sheathing panel 5 panel 3.5 3.5 218 218 272 272 SWSwmd SWSaeismi 236 101 Transverse panel 7 panel 3 1 : 187 280 233 350 Use SW1 Use SW1 panel ,'280 350 panel 10 280 350 panel 11 '+ 280 350 panel 12 280 350 panel 13 ;.. 280 350 panel 14 280 350 panel 15 ..4280 350 panel 16 '280 350 ASW= 32.92 Use SW1 Use STHD14114RJ holdowns each side of panel as noted on plans rmaxi SWS pi ' R Fz Vfinal 0.095 166 1.000 6 4741 3319 Seismic rmaxl SWS pi R Fx Vfinal 0.074 144 1.000 6 4741 3319 c 0 t7 9 c d 0 0 v c 3 280 236 Check t DL h 9 1657 9 1714 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D 0 D 0• 10 1819 10 1666 10 1868 9 1721 9 1946 9 1946 9 1971 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Right panels 11.5 280 350 ':10 677 0 250 .7757 4550 50800'. 230 panel 2 7.5 280 350 0 0 entl TA wall en panel3 0 0 panel3. 12.25 280 350 0 0 70 0 0 - panel fl28O 350 0 0 [TA;RI 0 0 Sheathing panels panel 280 280 350 350 0 0 Sws nd SWSselsmi 254 109 Transverse panel 7 panel .280 280 350 350 Use SW1 Use SW1 panel 9 11.5 f 280 350 panel 10 - 280 350 panel 11 !280 280 350 - panel 12 '280 280 350 panel 13 280 350 panel 14 280 350 panel 15 280 350 panel 16 1.280 280 350 ASW= 30.5 Use SW2 Use STHD14 /14RJ holdowns each each side of panel as noted on plans Shear Walls _ Seismic I Wind Right of Pool panel 1 5 280 350 ':10 677 0 216 !2911 4550',. 254001 230 pane12 6 280 350 0 0 TARow -and TAwan -end 0 0 panel3. 12.25 280 350 0 0 0 84 0 0 panel 4 0 0 280 350 0 0 0 0 Sheathing panels panel6 : 280 280 350 350 0 0 SWS SWS 125 71 Longitudinal v panel 7 panel8 ": :280 280 350 350 Use SW1 Use SW1 panel 9 J 280 350 pane110 280 350 panelll 280 350 - panel12 '280 350 panel 13 280 350 panel 14 280 350 panell5 280 350 panel16 280 350 ASW= 23.25 Use SW1 Use STHD14 /14RJ holdowns each side of panel as noted on plans 0.124 155 1.000 6 4741 3319 rmax , SWS p R F„ Vflnal 0.227 102 1.000 6 2371 1659 c 0 v c k c 0 c7 c 254 9 1714 9 1914 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0. Check uplift V SWS DL h h' Uplift 2911 125 230 10 ':10 677 230 10 ':10 562 230 10 10 -157 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Right - pool equip panel 1 16 .. 280 350 0 45 ,1010 4550: 5000 0.625 29 1.500 6 467 490 Seismic 0 panel 280 350 TARoot -end TAww -end Ai Wii rM., SWS p R F, Vfnai Front & Rear of panel 1 panel 280 350 0 49 ,6 963 4550 5000 y 0.833 39 1.500 6 467 490 :0 panel ! 280 350 280 350 TARom -end TAwan -end 0 panel 280 350 SWS., SWSaeiamm 280 350 Sheathing VI panel 6 280 350 63 31 panel !280 panel 7 280 350 Use SW'I Use SW1 Longitudinal 7 panel 280 350 SWS, SWSsetsmm panel 9 - 280 350 280 350 82 41 panel 10 '= 280 350 panel - 280 350 panel 11 280 350 Transverse 71y panel 280 panel 12 280 350 panel 9 panel 13 '.280 280 350 panel 14 280 350 280 350 panel 15 280 350 panel 11 280 350 panel 16 : 280 350 panel 12 280 ASW= 16 Use SW1 panel 13 No Uplift 280 350 Shear Walls Uplift Length Seismic - Wind 0 Seismic 0 0 SWl SW2 TARo,i, TAwaii-int. V. Ai Wii rM., SWS p R F, Vfnai Front & Rear of panel 1 12 280 350. 4 ,6 963 4550 5000 y 0.833 39 1.500 6 467 490 :0 pool equip. panel 2 1 280 350 TARom -end TAwan -end 0 0 panel 3 - 280 350 28 42 panel !280 350 panel 280 350 SWS, SWSsetsmm Sheathing 7 panel 6 280 350 82 41 panel - 280 350 Use SW1 Use SW1 Transverse 71y panel 280 350 panel 9 280 350 panel 10 280 350 panel 11 280 350 panel 12 280 350 panel 13 280 350 w E panel 14 280 350 i panel 15 :280 350 0 panel 16 280 350 c ASW= 12...... Use SW1 Use STHD14 /14RJ holdowns each side of panel as noted on plans 63 B -295 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Check uplift V SWS DL In h' Uplift 983 82 100 8 ''.8 55 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 :0 0 0 0 0 0 0 0 0 0 N Anchor Bolts Bolt Size 112 in Base Shear V 6865 Ibs Bolt Capacity 530 Ibs /bolt Number of bolts required 12,95 Wall Length 47 ft Bolt Spacing 44 in Spacing to be used 32 in Use 1/2" anchor bolts @ 32" o.c„ as noted on plans Rear Bolt Size Base Shear V Bolt Capacity Number of bolts required Wall Length Bolt Spacing Spacing to be used 1/2 in 8043' lbs 530 Ibs /bolt 15.18 38'. ft 31 in 24 in Use 1/2" anchor bolts @ 24" o.¢.r as noted on plans Bolt Size Base Shear V Bolt Capacity Number of bolts required Wall Length Bolt Spacing Spacing to be used rooms 112_ in 7978 Ibs 530 Ibs /bolt 1505 29 ft 24 in 24 in Use 1/2" anchor bolts @ 24" o.c„ as noted on plans Bolt Size Base Shear V Bolt Capacity Number of bolts required Wall Length Bolt Spacing Spacing to be used 12 in 7757 Ibs 530 Ibs /bolt 1464 88`, ft 73 in 32 in Use 1/2" anchor bolts @ 32" o „c„ as noted on plans -13- Bolt Size 112: in Base Shear V 7757. Ibs Bolt Capacity 530 Ibs /bolt Number of bolts required 1464 Wall Length 20 ft Bolt Spacing 17 in Spacing to be used 16 in Use 1 /2" anchor bolts @ 16" o „c„ as noted on plans Bolt Size 112 ` in Base Shear V 3414' Ibs Bolt Capacity 530 Ibs /bolt Number of bolts required 6.44 Wall Length 53' ft Bolt Spacing 99 in Spacing to be used 32 in Use 1/2” anchor bolts @ 32" o.¢,, as noted on plans Bolt Size 112 ' in Base Shear V 1010' Ibs Bolt Capacity 530 Ibs /bolt Number of bolts required 191 Wall Length 16! ft Bolt Spacing 101 in Spacing to be used 32 in Use 1/2" anchor bolts @ 32" ox. as noted on plans Bolt Size Base Shear V Bolt Capacity Number of bolts required Wall Length Bolt Spacing Spacing to be used 1008 Ibs 530 Ibs /bolt 1,90 12 ft 76 in 32 in Use 1/2" anchor bolts @ 32" ox. as noted on plans -14- Anchor Bolts Bolt Size 112 in Base Shear V 6865 Ibs Bolt Capacity 530 Ibs /bolt Number of bolts required 12,95 Wall Length 47 ft Bolt Spacing 44 in Spacing to be used 32 in Use 1/2" anchor bolts @ 32" o.c„ as noted on plans Rear Bolt Size Base Shear V Bolt Capacity Number of bolts required Wall Length Bolt Spacing Spacing to be used 1/2 in 8043' lbs 530 Ibs /bolt 15.18 38'. ft 31 in 24 in Use 1/2" anchor bolts @ 24" o.¢.r as noted on plans Bolt Size Base Shear V Bolt Capacity Number of bolts required Wall Length Bolt Spacing Spacing to be used rooms 112_ in 7978 Ibs 530 Ibs /bolt 1505 29 ft 24 in 24 in Use 1/2" anchor bolts @ 24" o.c„ as noted on plans Bolt Size Base Shear V Bolt Capacity Number of bolts required Wall Length Bolt Spacing Spacing to be used 12 in 7757 Ibs 530 Ibs /bolt 1464 88`, ft 73 in 32 in Use 1/2" anchor bolts @ 32" o „c„ as noted on plans -13- Bolt Size 112: in Base Shear V 7757. Ibs Bolt Capacity 530 Ibs /bolt Number of bolts required 1464 Wall Length 20 ft Bolt Spacing 17 in Spacing to be used 16 in Use 1 /2" anchor bolts @ 16" o „c„ as noted on plans Bolt Size 112 ` in Base Shear V 3414' Ibs Bolt Capacity 530 Ibs /bolt Number of bolts required 6.44 Wall Length 53' ft Bolt Spacing 99 in Spacing to be used 32 in Use 1/2” anchor bolts @ 32" o.¢,, as noted on plans Bolt Size 112 ' in Base Shear V 1010' Ibs Bolt Capacity 530 Ibs /bolt Number of bolts required 191 Wall Length 16! ft Bolt Spacing 101 in Spacing to be used 32 in Use 1/2" anchor bolts @ 32" ox. as noted on plans Bolt Size Base Shear V Bolt Capacity Number of bolts required Wall Length Bolt Spacing Spacing to be used 1008 Ibs 530 Ibs /bolt 1,90 12 ft 76 in 32 in Use 1/2" anchor bolts @ 32" ox. as noted on plans -14- width of footing (in)= depth of footing (in)= Height of wall (in)= width of wall (in)= Roof Pitch= Angle= Cs= Effective snow load= Trib. Area, , Trib. AreaFlOOa= Trib. Areanoorf= wroof (A wffoorz (P wfloom (PiO= P.. (Plf)= Pother (A PT (A= Req.Soil Bearing (psf)= Footing Reinforcement: Note for footing rebar: 3' Foundation Wall: M 33.7 0.970 34 1334 (2) #4 bars cont. None Use #4 bars @ 24" o.c. vertical, (3) #4 bars horizontal Use 1/2" anchor bolts @ 32" o.c. w/ 2'W'W /16" plate washers I FOOTING / SHEAR WALL SCHEDULE (not all are necessarilv used) fists Designation Po st Size P1 Double Stud (Trimmer) Designation P2 Triple Stud (Trimmer) Edge P3 44 1 P4 6x6 6" P5 3 1/2" x 3 1/2" Parallam Post 2 P6 3 1/2" x 5 1/4" Parallam Post 4" P7 5 1/4" x 5 1/4" Parallam Post 3 P8 Four Studs (Trimmers) 3" otings 4 Designation Footing Size Reinforcement Crosswise FT1 20 "x10" xcont, (2) #4 bars cont. None FT2 18 °x10 "xcont (2) #4 bars cont None FT3 24 "x24'xl0" (3) #4 bars each way FT4 30'x30 "x10" (3) #4 bars each way FT5 36'x36'x12" (4) #4 bars each way FT6 42" x42'xl2" (5) #5 bars each way FT7 48'x48 °x12" (5) #5 bars each way FT8 dear Walls Spacing Designation Material Nails Edge Field 1 7/16" OSB or CDX plywood 8d 6" 12" 2 7116" OSB or CDX plywood 8d 4" 12" 3 7116" OSB or CDX plywood 8d 3" 12" 4 7/16" OSB or CDX plywood 8d 6" 12" (each side) 5 7/16" OSB or CDX plywood 8d 4" 12" (each side) 6 7/16" OSB or CDX plywood 8d 3" 12" (each side) 7 1/2" Sheet Rock or better 5d cooler 7" 7" -17- 7/16" OSB SHEATHING WITH 8d ' NAILS @ 6" O.C. BLOCK ALL FREE EDGES WITH 2x4 BLOCKS ROOF TRUSS A35 CLIPS @ l?,N O C DOUBLE TOP PLATES STUD WALL ® DRAG STRUT TRUSS DETAIL Epn6h FOik, Uf 81660 SCALE: 1' =1' ���� 801.79BL566 Fu601•TB&9783 -17-