HomeMy WebLinkAboutPLANS - 05-00158 - Steel Line - Office BuildingF a II Q C L U C t1" cc C C i! a E c Steele Line 1365 S 12th W I Lki U Q0 O CZ) ROOF PANEL FIELD CUT PANEL AT FRAMING (NOT BY IPS MEMBER. FILL VOID WITH LOOSE INSULATION (NOT BY IRS) PANEL KIC71 I ID WWOA 7n) 41 WALL TRIM SF -1 FIELD CUT TO FIT PROFILE OF CANOPY RAFTER SOFFIT PANEL (NOT BY IRS) ........ SOFFIT TRIM (NOT BY IRS) IPP WALL PANEL DETAIL IPP WALL PA GIRT S0) W/ EK-3 S.D. SCREWS (SCO085) HEAD TRIM FL-2626 1/4-14 X 7/8" SELF DRILLING- SCREW (SCO540) AT 12" O.C. DETAIL AT ACCESSORY HEAD IPP WALL PANEL--/ 1/4-14 X 7/8" SELF-DRILL SCREW (SCO540) AT 12" O.C. DETAIL INSIDE CORNER TRIM FL-2516 ATTACH W/ 1/8" RIVETS (HWO056) AT 12" O.C. 3/32 X 3/8 TAPE SEALANT (HW0001) CONTINUOUS IPP WALL PANEL PANEL CLIP (HW0430) W/ (2) 1/4-14 X S' TEK-3 S.D. SCREWS (SCO085) . . . . . . ... . . . . . . . . . . I PP OD WAL PAN WALL PAN SEE PLAN — AT OZS CORNER 1/8" X 3/4" FOAM TAPE (HWO315) CONTINUOUS JAMB TRIM FL-2666 DETAIL ( G � AT ACCESSORY JAMB 1/8 X 3/4 FOAM TAPE (HW0315) CONTINUOUS BASE ANGLE (1 BY IPS) F CONCRETE 3/8" DIA DEAD OF BI)TYL SEALANT (HW0301) CONTINUOUS DETAIL L D AT WALL 36" IPP WAL JOINT SEALANT - PANEL CLIP INTERIOR FACE EXTERIOR FACE SEE DETAIL "A" JOINT SEALANT APPLICATION (2) 1/4-14 X 3" TEK-3 S.D. SCREWS (SCO085) COLD FORM FRAMING (NOT BY IRS) 1/4-14 X 7/8" S.D. SCREWS (SCO540) AT 12" O.C. REF. PLAN AT EAVEWZ CANOPY 00 FIELD CUT PANEL AT FRAMING MEMBER. FILL VOID WITH LOOSE ROOF PANEL INSULATION (NOT BY IPS) (NOT BY IPS) ,-PURLIN FLASHING SF-2 FIELD CUT TO FIT FRAMING MEMBER SOFFIT PAN (NOT BY IRS) SOFFIT TRIM (NOT BY IPS) 1/4-14 X 7/8" S.D. SCREW (SCO540) AT 12" O.C. IPP WALL PANEL-- DETAIL ... rr .4011 PURLIN ''A611 om> (NOT BY IRS) RAKE ANGLE (NOT BY IRS) ... PANEL CLIP (HW0430) W/ S 1/4-14 X 3" TEK-3 S.D. SCREWS (SCO085) REF. PLAN AT RAKE W/ PURLIN EXT, IPP WALL PANEL-- Lu w co 1/4-14 X 7/8" S.D. SCREWS -J (SCO540) AT 12" O.C. BETWEEN SUPPORT SCREWS #1 4 X 4" SCREWS (SC 9012 AT EACH FRAMING MEMBER OUTSIDE CORNER TRIM FL-2601 IPP WALL PANEL PANEL CLIP (HW0430)'W/ CHANNEL JAMB S (2D 3 (NOT BY IRS) . 2 3/4" X 1 1/4" X 14 GA. GALV. ANGLE "C" SECTION CLIP (HW0356) AT 24" O.C. SF -3 1/8" X 3/4" FOAM TAPE ATTACH W/ 5/16" X 1 3/8" FAB-LOK ATTACH TRIM AND ANGLE WITH FASTENERS (HWO360) (HW0315) CONTINUOUS "T" RIVETS (HW0211) AT 12" O.C. SILICONE SEALANT . ...... CHANNEL HEADER . . . . . . . . . . . . . (HWO313) (CONT.) (NOT BY IRS) . . . . . . . . . SILL TRIM FL - 2716 3 112" X 1 1/4" X 14 GA. GALV. ANGLE 3 ATTACH TRIM AND ANGLE WITH "T" RIVETS (HW0211) AT 12" O.C. 3 1 /nz" I RAKE TRIM AND PEAK BOX INSTALLATION APPLY CAULKING TO RAKE TRIM AS SHOWN PRIOR TO FINAL INSTALLATION. RAKE TRIM AND/OR PEAK BOX SHOULD LAP OVER RAKE TRIM A MINIMUM OF 2 INCHES. ATTACH TO WALL PANEL WITH FASTENERS AS SHOWN, ON RWP AND EIAIP WALL PANELS USE AN OUTSIDE CLOSURE TO SEAL PEAK BOX TO WALL PANEL. ATTACH PEAK TO ROOF PANEL WITH FASTENERS AND STITCH TO TRIM WITH BLIND RIVETS AS SHOWN. SEAL THE CONNECTION AT THE ROOF PANEL WITH TAPE SEALANT. SPLCE RAKE TRIM TOGETHER WITH BLIND RIVETS AS SHOWN AT PEAK BOX (1" O.C. MAX.) SEAL ALL RAKE TRIM LAPS WITH SEALANT TO ASSURE A WATER- TIGHT SEAL. , I :'EAK BOX ;.D. SCREW CREW FAIR , IFAIJIM APPLY CAULKING TO RAKE TRIM AS SHOWN PRIOR TO FINAL INSTALLATION, RAKE TRIM AND/OR PEAK BOX SHOULD LAP OVER RAKE TRIM A MINIMUM OF 2 INCHES. ATTACH TO WALL PANEL WITH FASTENERS AS SHOWN. ON RWP AND EWP WALL PANELS USE AN OUTSIDE CLOSURE TO SEAL PEAK BOX TO WALL PANEL. ATTACH PEAK TO ROOF PANEL WITH FASTENERS AND STITCH TO TRIM WITH BLIND RIVETS AS SHOWN. SEAL THE CONNECTION AT THE ROOF PANEL WITH TAPE SEALANT. SPLICE RAKE TRIM TOGETHER WITH BLIND RIVETS AS SHOWN AT PEAK BOX (1" O.C. MAX.) SEAL ALL RAKE TRIM LAPS WITH SEALANT TO ASSURE A WATER- TIGHT SEAL. 01 P1 1 ) EAK BOX �.D- SCREW CREW CUTTER CAULKING - CORN -- -R BOX INS CAULK ANC INSTALL AN ENDCAP IN THE END OF A SECTION OF GUTTER AND FASTEN WITH BLIND RIVETS. POST - ION THE GUTTER AND RAKE TRIM ALLOWING A MINIMUM OF 3" OVERLAP WITH THE CORNER BOX. THE CORNER BOX LAPS OVER THE GUTTER AND UNDER THE RAKE TRIM, AN ALTERNATE METHOD IS TO ASSEMBLE THE CORNER BOX TO A SECTION OF RAKE OR GUTTER AND LIFT INTO POSIT ON. ALIGN THE CORNER BOX FOR GOOD APPEARANCE AND FASTEN WITH BLIND RIVETS. SEAL CONNECTION WITH CAULK, CLCSURE AND SEALANT AS SHOWN, CAULK OVER RIVETS LOCATED ON SOP SIDE OF CORNER BOX. 3" CAJI Z ENDCAP - ( - "AULKING CORNER BOX 1-1 IV RAKE AND SAVE T - ;RIM ENDCAP INSTALLATION FOR BUILDINGS WITH EAVE TRIM INSTEAD OF GUTTER, INSTALL RAKE AND EAVE TRIM EAVE ENDCAPS AS SHOWN. ATTACH ENDCAPS WITH (10) BLIND RIVETS. GUTTER OUTLET, SEAL WITH GUTT FASTEN WITH BL DOW DOWNSPOUT DETAIL E P PANEL ................... �71.1.11.1.'_.'." EAVE TRIM D OWNSPOUT STRAP EAVE GUTTER 5 \-DOWNSPOUT ESP PANEL I PEAK BOX 22 BLIND RIVET IPF PANEL - 4 CORNER BOX 20 BLIND RIVET RWP PANEL --------- ------ ......... .... ..... . . TADC* L.FIL-mill I > EAVE TRIM BLIND RIVETS AT o'-i" O.C. (MAX.) TAPE SEALANT TAf (6) BLIND RIVE 3LIND RIVETS AT )'-l" O.C. (MAX.) TAPE SEALANT ............. CORNER TRIMS (8) BLIND RIVETS FLASHINC CAULK AND LAP DETAI-S RAKE TRIM HI-LO FLASHING BLIND RIVETS AT 0'-1" O.C. (MAX.) 3LIND RIVETS AT )'-l" O.C. (MAX.) SUGGESTED QUANTITY OF POP RIVETS AT TRIM ENDLAPS (I TRIM ENDCAP LOCATIONS NC. OF RIVETS REQ'D PER LAP EAVE TRIM 8 EAVE GUTTER 5 GUTTER ENDCAPS 5 RAKE TRIM I PEAK BOX 22 R IDGE CAP (INSIDE) 8 RIDGE CAP (OUTSIDE) - 4 CORNER BOX 20 DOWNSPC'UTS '2 ELBOWS 2 SLEEVES 2 CORNER TRIM (INSIDE) 7 CORNER TRIM (OUTSIDE) 5 HEAD & JAMB TRIM SPLICES AS REO'D NO REVISIONS PRWN I CHK,:) DATE 13202 MURNY RD. IV P.O. Box era STAMORD, TEXAS 77497-(W 11-20 14 % 6 0PIPS (2al)499-21505 ' f INSULATED PANEL SYSTrMS A DVASION Or NCI BUILDING SYSTEMS. L.P. STANDARD DETAILS DATE SCALE DRAWN CHECKED APPROVED JOP. NO. C WG. NO. N.T.S KM UVT1l'4%Jl VV I d IlNr•l EAVE GUTTER r-TAPE SEALANT F9 I, I C4 a T J am Right Elevation c ii 0 Left Elevation U r) Q) GO 6 Right Elevation _0 c Left Elevation r) 0 CO- a 6 m C - c Q) u) > Cy ry LJ _j c V) W * � 0 I.- 0 4- T) Q> -C 0 ry - 0 < c 0 0 Cc Q C3 .Mead = 3 t�XQO m C Right Elevation i _0 c r) 0 CO- a 6 - c Q) u) > Cy ry LJ _j c V) W * � 0 I.- 0 4- T) Q> -C 0 ry - 0 < c 0 0 0 Q C3 C7 3 3 i r 13 m ; T-10 1 f . � � .�. To 10'-9 3/4' 10'-3 1 co I CD 4' - I j 6040 5040 1 m 0 . m IU'-U 10 L V co c I D 16'-0' v 5040 60 ---------- ------- mo TOTAL AREA 2400 sq ft ■ I r An' -n' Q iM CONCRETE FOOTING SCHEDULE 20' --0' 20' -0' 20' -0` DEPTH WIDTH LENGTH TOP OF FTC . ELEVATION REINFORCEM T FE \11 �_ Z LONGITUDINAL - TRANSVERSE F1.9 PJF. F1.9 P IER 1 F3.0 1' -9` CONT I F3.0 O I I i - I ( I I I I I 0 , 3' -0" I I I i ! 0 I - F5.0 I ! I ! 5' -0" I 6 - # 6 - 0 - ! I I I 0 1. PiER 2 " Co S 1 F5.0 � Reinforcing Steel (Rebar) ASTM A615 - Grade 60 a � J. - PIER 2 - F5.0 E- W I I I Cr m 2. I I � ' ( I I b N frozen earth. + i I PIER 3 I i t- F3.0 PEIR 3 J F3.0 0) 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in lengths not to exceed 20 feet in any direction. 5. All construction joints shall be located so as not to impair the strength of the structure. Unless noted on the drawings, oil reinforcement shall be continuous through a '3� the joints. Each construction joint shall be keyed. 6. No aluminum products shall be embedded in the concrete. Electrical conduit shall be z � iM CONCRETE FOOTING SCHEDULE MARK DEPTH WIDTH LENGTH TOP OF FTC . ELEVATION REINFORCEM T REMARKS LONGITUDINAL - TRANSVERSE F1.9 g" 1' -9` CONT SEE PLAN 2 - # - - F3.0 9" 3' -0" 3' -0" SEE PLAN 4 - 14 4 - 1 4 - F5.0 9" 5' -0` 5' -0" SEE PLAN 6 - # 6 - 0 - SHt # CON T. ® OPENING #4 NOSING CONCRETE S.O.G. (SEE FDN PLAN) SLOPE TO DRAIN 41 Y2" PREMOLDED JOINT FILLER 14 x 24` ® 2' -0" O.C. 24" F_ CONCRETE S.O.G. (SEE FDN PLAN) SLOPE T O D RAIN Q Y 4 : x J11 14 8" CONCRETE WALL (SEE DWG NOTES FOR REQ'D REINF) D OOR OPENING DETAIL 1 DO NOT SCALE S1 0 100'-0" T O. S. 0 SECTION A -A 0 LN C PIER 1 SECTION A -A ►1 _ --Ai 96' -0" T. 0. S. SEE SCHED, 1 L• SEE SCHED (4) #4 VERT #3 TiES 0 10` O.C. (TRIPLE 0 A.B.) SECTION 4 DO NOT SCALE Si (2) #4 TOP & BOTTOM 14 0 3O" O.C. VFRT 1. 100' -0" -- / T.O.S. -- f ! . r SECTION B- B (10) #4 VERT f3 TIES 0 12` 0.C. 'TRIPLE 0 A.B.) RT 10` O.C. A.B.) (4) #4 VERT #3 TiES ® 10" 0. C. • (TRIPLE ® A.B.) J f (10) #4 VERT #3 TIES 0 12" O.C. (TRIPLE 0 A.B.) S ECTION A -A SECTION B -B NOTE: VERIFY ALi_ PIER LAYOUTS BETORE CONS TRO TiON PiER 3 SECTION 8­8 0) #4 VE_R T 3 TIES @ 12" O.0 RIPLE 0 A.B ) > it 1 A. 0 XLLJ H Q Q B. DESIGN LOADS 1. Design loads provided by others. Z 2. Footing and pier sizes based on steel building reactions provided by steel building zcn °rte °ZE manufacturer. awd tn o 1. cn m ") Lt. gravel and /or gravel (Table 18 -1 - -A, Class of Materials #3). Notify Engineer if conditions W ° rt 2. Bear footing on some type of undisturbed soil or rock throughout the entire structure. ?_ 1. Concrete f'c- (28 days) Ftgs & Walls 3000 PSI Co Slabs 3500 PSI co Reinforcing Steel (Rebar) ASTM A615 - Grade 60 a � J. - E- W 1. Cr m 2. 1 expected to drop below 40E F for 3 or more successive days. Place no concrete against W z frozen earth. + J. Conduct all compression tests according to ACI Standard Recommended Practice t- C7 0) 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in > it 1 A. q� XLLJ 1. International Building Code (IBC) - 2000 Edition Q 2. ACI 718 -99 Building Code Requirements for Reinforced Concrete B. DESIGN LOADS 1. Design loads provided by others. 2. Footing and pier sizes based on steel building reactions provided by steel building zcn °rte °ZE manufacturer. tn o 1. cn m ") t gravel and /or gravel (Table 18 -1 - -A, Class of Materials #3). Notify Engineer if conditions encountered are different. rt 2. Bear footing on some type of undisturbed soil or rock throughout the entire structure. D. MATERIALS 1. Concrete f'c- (28 days) Ftgs & Walls 3000 PSI Co Slabs 3500 PSI 2. Reinforcing Steel (Rebar) ASTM A615 - Grade 60 a � J. Anchor Bolts ASTM A307 (Minimum) E. REINFORCED CONCRETE 1. Concrete shall be of ready mix type conforming to ASTM C94. vi 2. 1 expected to drop below 40E F for 3 or more successive days. Place no concrete against z frozen earth. + J. Conduct all compression tests according to ACI Standard Recommended Practice C7 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in lengths not to exceed 20 feet in any direction. 5. All construction joints shall be located so as not to impair the strength of the structure. Unless noted on the drawings, oil reinforcement shall be continuous through a '3� the joints. Each construction joint shall be keyed. 6. No aluminum products shall be embedded in the concrete. Electrical conduit shall be =� placed at mid- height of the slabs and shall have an O.D. less than one -third the slab thickness. F. REINFORCING STEEL 1. All detailing, fabrication and placing of reinforcing bars shall conform to the ACI Manual o of Standard Practice for Detailing Reinforced Concrete Structures (ACI 315). ° m Provide corner bars at all intersecting corners. use some size bar and spacing as cs horizontal wall reinforcement. V) J. w w Minimum lap for splices shall be 40 bar diameters for masonry and 30 bar diameters for concrete, unless otherwise noted. v ► �� 4. All continuous reinforcement shall terminate with 90 degree return or hook or separate corner bar. 5. All vertical reinforcement in columns and wails shall be doweled from the footing or Y) structure below with rebor of the some size and spacing as required above. 6. Minimum concrete cover for reinforcing bars shall be as specified in Building Code Requirements for Reinforced Concrete (ACI 318). 7. Welding or tack welding of reinforcing bars is prohibited unless specifically approved by the Engineer. 8. All reinforcement to be supported in the forms and spaced with wire or plastic bar � 0 y reinforced concrete structures (ACi 315). Reinforcement in footing shall be supported on Q> r-2 p precast concrete block supports conforming to Concrete Reinforcing Steel institute Manual of Standard Practice. �# Cow 6 , MISCELLANEOUS NOTES 1. Orient pier details to match building layout. 2. Refer to steel building manufacturer's anchor bolt plan for anchor bolt size and layout. J. Contractor to verify all dimensions with steel building manufacturer before construction 0 0 C11 C) r 4. p Q + W NO CHANGES PERMITTED WITHOUT EXPRESS WRITTEN PERMISSION OF ENGINEER. O H. DEFERRED SUBMITTALS List of deferred submittals (shop drawings) that require Architectural and /or O Wo Engineering review and approval before fabrication or installation begins: 1. Anchor Bolt Plan. f0. W W CD PROA_ C T NC, 2043 SHE T NO. - �1 OF ONE 7 S1 FOUNDATION PLAN SCALE: 114" = 1' -0" 96'-0" T.O. w. SEE SCHED S ECTION 3 DO NOT SCALE S1 100'--0' T. 0. S. GENERAL STRUCTURAL NOTES A. CODES AND SPECIFICATIONS 1. International Building Code (IBC) - 2000 Edition 2. ACI 718 -99 Building Code Requirements for Reinforced Concrete B. DESIGN LOADS 1. Design loads provided by others. 2. Footing and pier sizes based on steel building reactions provided by steel building manufacturer. C. FOOTING & PIERS 1. Bearing pressure taken as 2000 PSF for column and wall footings, based on a sandy gravel and /or gravel (Table 18 -1 - -A, Class of Materials #3). Notify Engineer if conditions encountered are different. 2. Bear footing on some type of undisturbed soil or rock throughout the entire structure. D. MATERIALS 1. Concrete f'c- (28 days) Ftgs & Walls 3000 PSI Slabs 3500 PSI 2. Reinforcing Steel (Rebar) ASTM A615 - Grade 60 J. Anchor Bolts ASTM A307 (Minimum) E. REINFORCED CONCRETE 1. Concrete shall be of ready mix type conforming to ASTM C94. 2. Comply with ACi 306 Cold Weather Concrete standards if the mean daily temperature is expected to drop below 40E F for 3 or more successive days. Place no concrete against frozen earth. + J. Conduct all compression tests according to ACI Standard Recommended Practice for Evaluation of Compression Test Results of Field Concrete (ACi 214). 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in lengths not to exceed 20 feet in any direction. 5. All construction joints shall be located so as not to impair the strength of the structure. Unless noted on the drawings, oil reinforcement shall be continuous through the joints. Each construction joint shall be keyed. 6. No aluminum products shall be embedded in the concrete. Electrical conduit shall be placed at mid- height of the slabs and shall have an O.D. less than one -third the slab thickness. F. REINFORCING STEEL 1. All detailing, fabrication and placing of reinforcing bars shall conform to the ACI Manual o of Standard Practice for Detailing Reinforced Concrete Structures (ACI 315). ° 2. Provide corner bars at all intersecting corners. use some size bar and spacing as cs horizontal wall reinforcement. V) J. Splices of reinforcement at points of maximum stress shall be avoided wherever possible. w Minimum lap for splices shall be 40 bar diameters for masonry and 30 bar diameters for concrete, unless otherwise noted. ds 4. All continuous reinforcement shall terminate with 90 degree return or hook or separate corner bar. 5. All vertical reinforcement in columns and wails shall be doweled from the footing or Y) structure below with rebor of the some size and spacing as required above. 6. Minimum concrete cover for reinforcing bars shall be as specified in Building Code Requirements for Reinforced Concrete (ACI 318). 7. Welding or tack welding of reinforcing bars is prohibited unless specifically approved by the Engineer. 8. All reinforcement to be supported in the forms and spaced with wire or plastic bar � supports conforming to requirements of the ACi Manual of Standard Practice for detailing reinforced concrete structures (ACi 315). Reinforcement in footing shall be supported on Q> precast concrete block supports conforming to Concrete Reinforcing Steel institute Manual of Standard Practice. G. MISCELLANEOUS NOTES 1. Orient pier details to match building layout. 2. Refer to steel building manufacturer's anchor bolt plan for anchor bolt size and layout. J. Contractor to verify all dimensions with steel building manufacturer before construction begins. Steel building dimensions have precedence. 4. Do not scale drawings. 5. NO CHANGES PERMITTED WITHOUT EXPRESS WRITTEN PERMISSION OF ENGINEER. H. DEFERRED SUBMITTALS List of deferred submittals (shop drawings) that require Architectural and /or Engineering review and approval before fabrication or installation begins: 1. Anchor Bolt Plan. SECTION A -A n 60'-0" M W r hM CONCRETE FOOTING SCHEDULE 20' - 20' - DEP TH WIDTH LENG TOP OF FTG ELEVATION REINFORCEMEN T REMARKS Z TRANSVERSE F1.9 9" F1.9 p iFff_l IF CONT SEE PLA 2 - #4 F J. 0 _/�Z F3. 0 F3. 9" 3' -0" 3'-0* SEE PLAN 4 - #4 4 #4 F5.0 9. 5 ' -0 5' -0" SEE PLAN 6 - #4 6 14 C:) D. MATERIALS 1. * Q1 PIER 2 F5 Slobs 3500 PSI St Reinforcing Steel (Rebor) ASTM A615 - Grade 60 PIER 2 - F5.0 j. Anchor Bolts ASTM A307 (Minimum) E. REINFORCED CONCRETE 1. Concrete shall be of ready mix type conforming to ASTM C94. Q Comply with ACI 306 Cold Weather Concrete standards ' 'f the mean daily temperature is expected to drop below 40F F for 3 or more successive days. Place no concrete against PIER 3 frozen earth. J. PEIR J F3.0 I for Evaluation of Compression Test Results of Field Concrete (ACI 214). F3. 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in lengths not to exceed 20 feet in any direction. ZE 5. All construction joints shall be located so as not to impair the strength of the structure. Unless noted on the drawings, all reinforcement shall be continuous through L the joints. Each construction joint shall be keyed. 6. No aluminum products shall be embedded in the concrete. Electrical conduit shall be placed at mid-height of the slabs and shall hove on O.D. less than one-third the slob W r hM CONCRETE FOOTING SCHEDULE MARK DEP TH WIDTH LENG TOP OF FTG ELEVATION REINFORCEMEN T REMARKS LONGITUDINAL TRANSVERSE F1.9 9" 1'-9* CONT SEE PLA 2 - #4 F3. 9" 3' -0" 3'-0* SEE PLAN 4 - #4 4 #4 F5.0 9. 5 ' -0 5' -0" SEE PLAN 6 - #4 6 14 C:) SH( #4 CON T. 0 OPENING 14 NOSING CONCRETE S.O.G. (SEE FDN PLAN) SLOPE TO DRAIN PREMOLDED JOIN FILLER 14 x 24" 0 2'-0" O.C. 24" F_ CONCRE TE S. 0. G. (SEE FDN PLAN) SLOPE TO DRAIN V 4 8 CONCRETE WALL (SEE D WG NOTES FOR REQD REINE) DOOR OPENING DETAIL DO NOT SCALE FOUNDATION PLAN SCALE: 114 " = 1 , - 0" PIER DETAIL r2_'� DO NOT SCALE S1 1-1-1 100'--0" T. O.S. 1 6 SECTION A-A -no rLL1 100'_0" T: 0. S. * 1 1 A • SEE SCHED. SECTION B SEE SCHED S[CTiON A---A 96 T. 0. S. (4) #4 VER T #,5 IYS 0 10 O.C. (TRIPLE 0 A.B.) SECTION 00 NOT SCALE S 1�) (10) #4 VERT ¢_5 RES 0 12 O.C. 'TRIPLE 0 AB.) RT 10* aur, A. B.) (4) #4 VER T #3 TIES @ 10" O.C. (TRIPLE @ A.B.) SECTION B-B /_1 " . --- - - - ON I Alp I 00'_ 0 T. O.S. SECTION 00 NOT SCALE (t 0) #4 VER T #3 n1. S 0 12 0. C. (TRIPLE 0 A.R.) SECTION _ A --A 4f A SECTION R- J? 0) #4 VER T 5 Tif's (0 1.")* 'RIM 0 A R Z 0 Z 0 0 0 L W < LLJ Z C0 cc I D co X W 5 Cr M _J Cn PRO1 CT , !V(' 9 I NO - ..... .. ....... - - ------ Of ONF r GENERAL STRUCTURAL NOTES A. CODES AND SPECIFICATIONS q 1. International Building Code (13C) --- 2000 Edi tion ZZI "I L, Q CL i. (:5 UJ Ck B. DESIGN LOADS 0 6 Zn LZ 2. Footing and pier sizes based on steel building reactions provided by steel building rnonufacturet. C. FOOTING& PIERS 1. Bearing pressure taken as 2000 PSF for column and wall footings, based on 0 sandy gravel andlor grovel (Table 18-- /--A, Class of Materials #3). Notify Engineer if conditions encountered are different. 2. C:) D. MATERIALS 1. Concrete f , c- (28 days) Ftgs & Walls 3000 PSI Slobs 3500 PSI 2. Reinforcing Steel (Rebor) ASTM A615 - Grade 60 j. Anchor Bolts ASTM A307 (Minimum) E. REINFORCED CONCRETE 1. Concrete shall be of ready mix type conforming to ASTM C94. Q Comply with ACI 306 Cold Weather Concrete standards ' 'f the mean daily temperature is expected to drop below 40F F for 3 or more successive days. Place no concrete against ( frozen earth. J. Conduct all compression tests according to ACI Standard Recommended Practice for Evaluation of Compression Test Results of Field Concrete (ACI 214). 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in lengths not to exceed 20 feet in any direction. ZE 5. All construction joints shall be located so as not to impair the strength of the structure. Unless noted on the drawings, all reinforcement shall be continuous through the joints. Each construction joint shall be keyed. 6. No aluminum products shall be embedded in the concrete. Electrical conduit shall be placed at mid-height of the slabs and shall hove on O.D. less than one-third the slob thickness. F. REINFORCING STEEL M All detailing, fabrication and placing of reinforcing bars shall conform to the ACI Manual of Standard Practice for Detailing Reinforced Concrete Structures (ACI 315). 2. Provide corner bars at all intersecting corners. use some size bar and spacing as horizontal wall reinforcement. J. Splices of reinforcement at points of maximum stress shall be avoided wherever possible. to Minimum lop for splices shall be 40 bar diameters for masonry and 30 bar diameters for concrete, unless otherwise noted. L-Q All continuous reinforcement shall terminate with 90 degree return or hook or separate corner bar, 5. All vertical reinforcement in columns and walls shall be doweled from the footing or structure below with rebor of the some size and spacing as required above. 6. Minimum con ' crete cover for reinforcing bars shall be as specified in Building Code V) Z Requirements for Reinforced Concrete (ACI 318). 7 Welding or tack welding of reinforcing bars is prohibited unless specifically approved by the Engineer. 8. All reinforcement to be supported in the forms and spaced with wire or plastic bar 00 n supports conforming to requirements of the ACI Manual of Standard Practice for detailing reinforced concrete structures (ACI 315). Reinforcement in footing shall be supported on Q..) CN n of Standard Practice. Lin G. MISCELLANEOUS NOTES i > 7 1. 0 J 0 J. Contractor to verify all dimensions with steel building manufacturer before construction 7) N c 0 0 CL 4. Do not scale drawings. 5. NO CHANGES PERMITTED WFHOUT EXPRESS WITTEN PERMISSION %f % PRO1 CT , !V(' 9 I NO - ..... .. ....... - - ------ Of ONF r GENERAL STRUCTURAL NOTES A. CODES AND SPECIFICATIONS 1. International Building Code (13C) --- 2000 Edi tion 2. ACi 718--99 Building Code Requirements for Reinforced Concrete B. DESIGN LOADS 0 Design loods provided by others. 2. Footing and pier sizes based on steel building reactions provided by steel building rnonufacturet. C. FOOTING& PIERS 1. Bearing pressure taken as 2000 PSF for column and wall footings, based on 0 sandy gravel andlor grovel (Table 18-- /--A, Class of Materials #3). Notify Engineer if conditions encountered are different. 2. Bear tooting ng on some type of undisturbed soil or rock throughout the entire structure. D. MATERIALS 1. Concrete f , c- (28 days) Ftgs & Walls 3000 PSI Slobs 3500 PSI 2. Reinforcing Steel (Rebor) ASTM A615 - Grade 60 j. Anchor Bolts ASTM A307 (Minimum) E. REINFORCED CONCRETE 1. Concrete shall be of ready mix type conforming to ASTM C94. 2. Comply with ACI 306 Cold Weather Concrete standards ' 'f the mean daily temperature is expected to drop below 40F F for 3 or more successive days. Place no concrete against frozen earth. J. Conduct all compression tests according to ACI Standard Recommended Practice for Evaluation of Compression Test Results of Field Concrete (ACI 214). 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in lengths not to exceed 20 feet in any direction. 5. All construction joints shall be located so as not to impair the strength of the structure. Unless noted on the drawings, all reinforcement shall be continuous through the joints. Each construction joint shall be keyed. 6. No aluminum products shall be embedded in the concrete. Electrical conduit shall be placed at mid-height of the slabs and shall hove on O.D. less than one-third the slob thickness. F. REINFORCING STEEL 1. All detailing, fabrication and placing of reinforcing bars shall conform to the ACI Manual of Standard Practice for Detailing Reinforced Concrete Structures (ACI 315). 2. Provide corner bars at all intersecting corners. use some size bar and spacing as horizontal wall reinforcement. J. Splices of reinforcement at points of maximum stress shall be avoided wherever possible. to Minimum lop for splices shall be 40 bar diameters for masonry and 30 bar diameters for concrete, unless otherwise noted. 4. All continuous reinforcement shall terminate with 90 degree return or hook or separate corner bar, 5. All vertical reinforcement in columns and walls shall be doweled from the footing or structure below with rebor of the some size and spacing as required above. 6. Minimum con ' crete cover for reinforcing bars shall be as specified in Building Code V) Z Requirements for Reinforced Concrete (ACI 318). 7 Welding or tack welding of reinforcing bars is prohibited unless specifically approved by the Engineer. 8. All reinforcement to be supported in the forms and spaced with wire or plastic bar supports conforming to requirements of the ACI Manual of Standard Practice for detailing reinforced concrete structures (ACI 315). Reinforcement in footing shall be supported on Q..) precast concrete block supports conforming to Concrete Reinforcing Steel institute Manual of Standard Practice. G. MISCELLANEOUS NOTES 1. Orient pier details to match building layout. 2. Refer to steel building manufacturer's anchor bolt pion for anchor bolt size and layout. J. Contractor to verify all dimensions with steel building manufacturer before construction begins. Steel building dimensions hove precedence. 4. Do not scale drawings. 5. NO CHANGES PERMITTED WFHOUT EXPRESS WITTEN PERMISSION OF ENGINEER. H. DEFERRED SUBMITTALS List of deferred submittals (shop drawings) that require Architectural and /or Engineering review and approval before fabrication or installation begins: 1. Anchor Bolt Plan, NO TE. VLRIFY AI- PIER LAYOUTS BEFORE, CONS Tf?UC TION i SEE SCHED �, SEE SCHED �, SECTION A-A An 0 LNG CONCRETE FOOTING SCHEDULE 20 20'-0' DEP TH WIDTH LENGTH TOP OF FTC ELEVA TION REINFORCEMENT REMARKS LONGITUDINAL TRANSVERSE F_ 9- 1'-9 CONT F1. F_ PIER 1 F3. 2 - #4 2. Z FJ,O 9 3 1 -0 . 3I-0. SEE PLAN o 4 #4 1. F5,0 9 5'- 0' 5'-0" SEE PLAN 6 - #4 6 14 2. Hear footing on some type of undisturbed soil or rock throughout the entire structure, A 2 co Concrete f'c- (28 day-,' Figs & Walls 3000 PSI Q PIER 2 PIER 2 - 2. Reinforcing Steel (Debar) ASTM A615 ­ Grade 60 F5.0 J. Anchor Botts ASTM A307 (Minimum) E. REINFORCED CONCRETE o cry Concrete shall be of ready mix type conforming to ASTM C94. 2. Comply with ACI 306 Cold Weather Concrete standards if the mean daily temperature is PIER 3 FS 0 expected to drop below 40E F for 3 or more successive days. Place no concrete against PEIR J FJ, 0 J. Conduct all compression tests according to ACI Standard Recommended Practice for Evaluation of Compression Test Results of Field Concrete (ACI 214), L 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in (A) lengths not to exceed 20 feet in any direction. LNG CONCRETE FOOTING SCHEDULE MARK DEP TH WIDTH LENGTH TOP OF FTC ELEVA TION REINFORCEMENT REMARKS LONGITUDINAL TRANSVERSE F1.9 9- 1'-9 CONT SEE PLA 2 - #4 2. Z F3. 9 3 1 -0 . 3I-0. SEE PLAN 4 - #4 4 #4 1. F5,0 9 5'- 0' 5'-0" SEE PLAN 6 - #4 6 14 WALL REINF CONT THRU PIER (NO F SHOWN FOR CLARITY) A #4 CON T, 0 OPENING #4 NOSING CONCRE TE S. 0. G. (SEE FDN PLAN) SLOPE TO DRAIN 4 lei" PREMOLDED JOINT FILLER 14 x 24" @ 2' - 0. C. 24 [_ - CONCRETE S.O.G. (SEE FDN PLAN) SLOPE TO DRAIN 8" CONCRETE WALL (SEE DWG NOTES FOR REQD REINF) DOOR OPENING DETAIL I DO NOT SCALE S, FOUNDATION PLAN SCALE 114" = STEEL BUILDING FRAME BY OTHERS )A 100'-0' T.O.S. -1d SECTION A-A \4& I Ma� i 11 SECTION A-A 8' --Ai 96'- 0 T, O.S. • SEE SCHED. -I SEE SCHED SECTION B-B 100' -`0" T. O. S. (4) #4 VER T #J nES a 10 ac (TRIPLE 0 A.8.) SECTION r4 DO NOT SCALE Si (1 #4 VER T VJ TIES 0 12 O. C. `TRIPLE 0 A.B.) i?T 10" O.C. A.H.) (4) #4 VER T TIES @ 10 O. C. • (TRIPL @ A. B.) ----- -(10) #4 VERT #3 TIES 0 12 O. C. F (TRIPLE @ A.B.) SECTION B-B SECTION A--A 44 SEC TION B -- B 0) #4 VER T 3 TIES @ 12' 0. C. 'RIPLE 0 A.B.) Z 0 • Z • 0 L W UJ 9 & rt Z % CC X LU CC W W PROJ[ C T �40 1 20437,3 AJO, �1 OF ONF TOM T 100'-0" T. O. S. . SEE SCHED SECTION DO NOT SCALE Si GENERAL STRUCTURAL NOTES A. CODES AND SPECIFICATIONS 4" Vi 1. International Building Code (113C) 2000 1 dition 2. ACI 718--99 Building Code Requirements for Reinforced Concrett B. DESIGN LOADS 1. Design loads provided by others_ Z) 2. Z J! Q) manufacturer. C. FOOTING& PIERS 1. Rearing pressure taken as 2000 PSF for column and wall footings, based or) 0 sandy gravel ondlor gravel (Table 18 -I --A, Class of Materials #3). Notify Engineer i conditions encountered are different. 2. Hear footing on some type of undisturbed soil or rock throughout the entire structure, D. MATERIALS co Concrete f'c- (28 day-,' Figs & Walls 3000 PSI Slobs 3500 PSI 2. Reinforcing Steel (Debar) ASTM A615 ­ Grade 60 J. Anchor Botts ASTM A307 (Minimum) E. REINFORCED CONCRETE cry Concrete shall be of ready mix type conforming to ASTM C94. 2. Comply with ACI 306 Cold Weather Concrete standards if the mean daily temperature is expected to drop below 40E F for 3 or more successive days. Place no concrete against frozen earth. J. Conduct all compression tests according to ACI Standard Recommended Practice for Evaluation of Compression Test Results of Field Concrete (ACI 214), 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in 1 lengths not to exceed 20 feet in any direction. 5. All construction joints shall be located so as not to impair the strength of the structure. Unless noted on the drawings, all reinforcement shall be continuous through the joints. Each construction joint shall be keyed. 6. Z:_ placed at mid-height of the stabs and shall hove on O.D. less than one-third the slab thickness. F. REINFORCING STEEL 1. All detailing, fabrication and placing of reinforcing bars shall conform to the ACI Manual of Standard Practice for Detailing Reinforced Concrete Structures (ACI 315). 2. Provide corner bars at all intersecting corners. use some size bar and spacing as horizontal wall reinforcement. al J. Splices of reinforcement at points of maximum stress shall be avoided wherever possible. Minimum lop for splices shall be 40 bar diameters for masonry and JO bor diameters for concrete, unless otherwise noted. 4. All continuous reinforcement shall terminate with 90 degree return or hook or separate corner bar. 5. All vertical reinforcement in columns and walls shall be doweled from the footing or structure below with rebor of the some size and spacing as required above, 6. Minimum concrete cover for reinforcing bars shall be as specified in Building Code Requirements for Reinforced Concrete (ACI 318). 7. C) the Engineer. 8, All reinforcement to be supported in the forms and spaced with wire or plastic bar c supports conforming to requirements of the ACI Manual of Standard Practice for detailing reinforced concrete structures (ACI 315). Reinforcement in footing shall be supported on U precast concrete block supports conforming to Concrete Reinforcing Steel institute Manual of Standard Practice. G. MISCELLANEOUS NOTES 1. Orient pier details to match building layout. 2. Refer to steel building manufacturer's anchor bolt plan for anchor bolt size and layout. co 0 3. Contractor to verify all dimensions with steel building manufacturer before construction begins. Steel building dimensions have precedence. 4. Do not scale drawings. c" 5. NO CHANGES PERMITTED W THOU T EXPRESS WRITTEN PERMISSION u') 0 H. DEFERRED SUBMITTALS W 0 I -K C) 0 Engineering review and approval before fabrication or installation begins: C) E --- 4 7. Anchor Bolt Plan. Ilk) PROJ[ C T �40 1 20437,3 AJO, �1 OF ONF TOM T 100'-0" T. O. S. . SEE SCHED SECTION DO NOT SCALE Si GENERAL STRUCTURAL NOTES A. CODES AND SPECIFICATIONS 1. International Building Code (113C) 2000 1 dition 2. ACI 718--99 Building Code Requirements for Reinforced Concrett B. DESIGN LOADS 1. Design loads provided by others_ 2. Footing and pier sizes based on steel building reactions provided by steel building manufacturer. C. FOOTING& PIERS 1. Rearing pressure taken as 2000 PSF for column and wall footings, based or) 0 sandy gravel ondlor gravel (Table 18 -I --A, Class of Materials #3). Notify Engineer i conditions encountered are different. 2. Hear footing on some type of undisturbed soil or rock throughout the entire structure, D. MATERIALS I- Concrete f'c- (28 day-,' Figs & Walls 3000 PSI Slobs 3500 PSI 2. Reinforcing Steel (Debar) ASTM A615 ­ Grade 60 J. Anchor Botts ASTM A307 (Minimum) E. REINFORCED CONCRETE 1. Concrete shall be of ready mix type conforming to ASTM C94. 2. Comply with ACI 306 Cold Weather Concrete standards if the mean daily temperature is expected to drop below 40E F for 3 or more successive days. Place no concrete against frozen earth. J. Conduct all compression tests according to ACI Standard Recommended Practice for Evaluation of Compression Test Results of Field Concrete (ACI 214), 4. Control joints in large areas of slab on grade shall be placed in checkerboard fashion in 1 lengths not to exceed 20 feet in any direction. 5. All construction joints shall be located so as not to impair the strength of the structure. Unless noted on the drawings, all reinforcement shall be continuous through the joints. Each construction joint shall be keyed. 6. No aluminum products shall be embedded in the concrete. Electrical conduit shall be placed at mid-height of the stabs and shall hove on O.D. less than one-third the slab thickness. F. REINFORCING STEEL 1. All detailing, fabrication and placing of reinforcing bars shall conform to the ACI Manual of Standard Practice for Detailing Reinforced Concrete Structures (ACI 315). 2. Provide corner bars at all intersecting corners. use some size bar and spacing as horizontal wall reinforcement. J. Splices of reinforcement at points of maximum stress shall be avoided wherever possible. Minimum lop for splices shall be 40 bar diameters for masonry and JO bor diameters for concrete, unless otherwise noted. 4. All continuous reinforcement shall terminate with 90 degree return or hook or separate corner bar. 5. All vertical reinforcement in columns and walls shall be doweled from the footing or structure below with rebor of the some size and spacing as required above, 6. Minimum concrete cover for reinforcing bars shall be as specified in Building Code Requirements for Reinforced Concrete (ACI 318). 7. Welding or tack welding of reinforcing bars is prohibited unless specifically approved by the Engineer. 8, All reinforcement to be supported in the forms and spaced with wire or plastic bar c supports conforming to requirements of the ACI Manual of Standard Practice for detailing reinforced concrete structures (ACI 315). Reinforcement in footing shall be supported on U precast concrete block supports conforming to Concrete Reinforcing Steel institute Manual of Standard Practice. G. MISCELLANEOUS NOTES 1. Orient pier details to match building layout. 2. Refer to steel building manufacturer's anchor bolt plan for anchor bolt size and layout. 3. Contractor to verify all dimensions with steel building manufacturer before construction begins. Steel building dimensions have precedence. 4. Do not scale drawings. 5. NO CHANGES PERMITTED W THOU T EXPRESS WRITTEN PERMISSION OF ENGINEER. H. DEFERRED SUBMITTALS List of deferred submittals (shop drawings) that require Architectural and/or Engineering review and approval before fabrication or installation begins: 7. Anchor Bolt Plan. NO TE: VERIFY AL L PIER LA YOU TS BEFORE CONS TRUC F/ON SEC HON A-A - — -------- rilLl'� r I�p�il L I t E a t Unj ril I ko CO r) LJ CO LJ C: V 4r� V Ay NQ CL 4ul > C) (n LAJ x c Lij LJ C: V 4r� V Ay NQ CL 4ul > (n LAJ x c Lij 0 o o C) T� o (1) CL - C (D c). ......... . ................ . . __. . .... y � _ NMU C4 � w b . c ► _a --4—' kl) �J 1� T co Y LO b LO � - c; c r• a� � —r LLJ c �? - � ^� .N 0 0 a, �. c> ICY ILIJ o CL t `• 0 C J a. �. o L c Y: I 0 1'l'-9 -" .... .... v 5' -6 "' :3068 IL Cy) v ------------- ------------- -- -------- - Ci 0 co 'D 16 0 5C40 6040 - 1 J. a,' - 4 _7 ------------- ---- - - ------- - --------- - ---------- CD co ------------- ---- - - ------- - --------- - ---------- co LO W ------------- ---- - - ------- - --------- - ---------- 0 c o FUTURE SEWER m MAIN EXTENSION - z> 8 -SWR 8 -SWR 8 -SWR 8 -SWR 8 -SWR 8 -SWR — 8 -SWR 8 -SYR 8 -SWR 8 -SWR 8 -SWR 8 -SWR 8 -SWR 8 -SWR < N U r 12tH STREET WEST STREET CENTERLINE .� s FUTURE WATER MAIN EXTENSION v -4849. 2-WTR 12 - WTR 12 - WTR 12-WTR 12 - WTR 12 - WTR 12 - WTR 12 WTR 12 - WTR 12-WTR 12-WTR 12-WTR 12-W% - a o in n� . . . . . . . . . . . . . . . . . —_ . . . . . . . . . . . . . . . . . . . . . . . . S00'24 '22'E $ $ 3 _ 3 83.13'_ _ _ -x- �• _ _ �C -' X_ _ X _ _ X — o _ — RIGHT -OF -WAY 1!QrPARKA 6' -1Rl'A EXISTING ° z w r . WELL o , Sj WALK :y .:. •`, ,: PROPOSED BUILDING ` g (40'X60') EXISTING SEPTIC do GRAINFIELD ao �o 0500159 Site Plan Steele Line 1365 S 12th W SS��hIAL F, GRAPHIC SCALE o 0 NOTE: SEWER AND WATER SERVICES CONNECT TO EXISTING WELL AND SEPTIC DRAIN FIELD. CONNECTION TO CITY UTILITIES WILL OCCUR WHEN AVAILABLE. 431.E s�11 04166, 4 , Ong R. o% "" DRAWN DEM -05 17 CHECKED DATE This document or any part thereof In detall DESIGNED WRD -05/17 _ or daetgn aoncspt Is tfy pe Of the r Group land hd be copied DATE pIM without Written author(wtlon of APPROVEo the Dyer Group. DATE poi TRI —STEEL CONSTRUCTION REXBURG, IDAHO DYER oROUpt& E NGINEERING • PLANNING • MAN PROJECT NO. 04039 SITE PLAN I SH EET 1 1 BUILDER / CONTRACTOR RESPONSIBILITIES IT IS THE RESPONSIBILITY OF THE BUILDER /CONTRACTOR TO INSURE THAT ALL PROJECT PLANS AND SPECIFICATIONS COMPLY WITH THE APPLICABLE REQUIREMENTS OF ANY GOVERNING BUILDING AUTHORITIES. THE SUPPLYING OF SEALED ENGINEERING DATA AND DRAWINGS FOR THE METAL BUILDING SYSTEM DOES NOT IMPLY OR CONSTITUTE AN AGREEMENT THAT METALLIC BUILDING COMPANY OR ITS DESIGN ENGINEER IS ACTING AS THE ENGINEER OF RECORD OR DESIGN PROFESSIONAL FOR A CONSTRUCTION PROJECT. THE CONTRACTOR MUST SECURE ALL REQUIRED APPROVALS AND PERMITS FROM THE APPROPRIATE AGENCY AS REQUIRED. APPROVAL OF METALLIC'S DRAWINGS AND CALCULATIONS INDICATE THAT METALLIC BUILDING COMPANY CORRECTLY INTERPRETED AND APPLIED THE REQUIREMENTS OF THE CONTRACT DRAWINGS AND SPECIFICATIONS. (SECT. 4.2.1 AISC CODE OF STANDARD PRACTICES, 9TH ED.) WHERE DISCREPANCIES EXIST BETWEEN METALLIC'S STRUCTURAL STEEL PLANS AND THE PLANS FOR OTHER TRADES, THE STRUCTURAL STEEL PLANS SHALL GOVERN. (SECT. 13 AISC CODE OF STANDARD PRACTICE 9TH ED.) DESIGN CONSIDERATIONS OF ANY MATERIALS IN THE STRUCTURE WHICH ARE NOT FURNISHED BY METALLIC BUILDING COMPANY ARE THE RESPONSIBILITY OF THE CONTRACTORS AND ENGINEERS OTHER THAN METALLIC BUILDING COMPANY'S ENGINEERS UNLESS SPECIFICALLY INDICATED, THE CONTRACTOR IS RESPONSIBLE FOR ALL ERECTION OF STEEL AND ASSOCIATED WORK IN COMPLIANCE WITH METALLIC BUILDING COMPANY'S "FOR CONSTRUCTION" DRAWINGS. PRODUCTS SHIPPED TO BUILDER OR HIS CUSTOMER SHALL BE INSPECTED BY BUILDER IMMEDIATELY UPON ARRIVAL. CLAIMS FOR SHORTAGES OR DEFECTIVE MATERIAL IF NOT PACKAGED MUST BE MAILED TO METALLIC IN WRITING WITHIN FIVE (5) DAYS AFTER RECEIPT OF THE SHIPMENT. HOWEVER, IF A DEFECT IS OF SUCH A NATURE THAT REASONABLE VISUAL INSPECTION WOULD FAIL TO DISCLOSE IT, THEN THE CLAIM MUST BE MADE WITHIN FIVE (5) DAYS AFTER THE BUILDER LEARNS OF THE DEFECT. METALLIC WILL NOT BE LIABLE FOR ANY DEFECT UNLESS CLAIM IS MADE WITHIN ONE (1) YEAR AFTER DATE OF THE ORIGINAL SHIPMENT BY METALLIC TO BUILDER OR HIS CUSTOMER. METALLIC WILL BE GIVEN A REASONABLE OPPORTUNITY TO INSPECT DEFECTIVE MATERIALS UPON RECEIPT OF CLAIM BY BUILDER. IF A DEFECT IS OF SUCH NATURE THAT IT CAN BE REMEDIED BY A FIELD OPERATION AT THE JOB SITE WITHOUT THE NECESSITY OF RETURNING THE MATERIAL TO METALLIC, THEN UPON WRITTEN AUTHORIZATION OF METALLIC THE BUILDER MAY REPAIR OR CAUSE THE MATERIAL TO BE REPAIRED AND METALLIC WILL REIMBURSE THE BUILDER FOR THE COST OF THE REPAIR IN ACCORDANCE WITH THE WRITTEN AUTHORIZATION. ALL BRACING AS SHOWN AND PROVIDED BY METALLIC FOR THIS BUILDING IS REQUIRED AND SHALL BE INSTALLED BY THE ERECTOR AS A PERMANENT PART OF THE STRUCTURE. TEMPORARY SUPPORTS, SUCH AS TEMPORARY GUYS, BRACES, FALSE WORK, CRIBBING OR OTHER ELEMENTS REQUIRED FOR THE ERECTION OPERATION WILL BE DETERMINED AND FURNISHED AND INSTALLED BY THE ERECTOR. THESE TEMPORARY SUPPORTS WILL SECURE THE STEEL FRAMING, OR ANY PARTLY ASSEMBLED STEEL FRAMING, AGAINST LOADS COMPARABLE IN INTENSITY TO THOSE FOR WHICH THE STRUCTURE WAS DESIGNED, RESULTING FROM WIND, SEISMIC FORCES AND ERECTION OPERATIONS, BUT NOT THE LOADS RESULTING FROM THE PERFORMANCE OF WORK BY OR THE ACTS OF OTHERS, NOR SUCH UNPREDICTABLE LOADS AS THOSE DUE TO TORNADO, EXPLOSION OR COLLISION. (SECT. 7.9.1 AISC CODE OF STANDARD PRACTICE, 9TH ED.) DESIGN OF GUTTER AND DOWNSPOUT IS A FUNCTION OF THE RAINFALL INTENSITY AND AREA TO BE DRAINED. DESIGN PARAMETERS UTILIZED ARE IN ACCORDANCE WITH THE 1986 LOW RISE BUILDING SYSTEMS MANUAL AND /OR THE 9TH EDITION OF THE ARCHITECTURAL GRAPHIC STANDARDS, AS APPLICABLE. PROPER OWNER MAINTENANCE DICTATES THAT THE DRAINAGE SYSTEM BE KEPT FREE AND CLEAR OF DEBRIS AND /OR ICE AT ALL TIMES TO ENSURE PROPER FUNCTION OF THE GUTTER AND DOWNSPOUT. IN THOSE CASES WHERE THE OWNER /TENANT OF A PROPERTY IS UNWILLING OR UNABLE TO PROVIDE PROPER MAINTENANCE, ELIMINATION OF GUTTER SHOULD BE CONSIDERED AS AN ALTERNATIVE. PRODUCT CERTIFICATIONS METALLIC BUILDING COMPANY IS A MEMBER OF THE METAL BUILDING MANUFACTURERS ASSOCIATION. METALLIC BUILDING COMPANY'S FABRICATION AND PRODUCTS ARE COVERED BY ONE OR MORE OF THE FOLLOWING CERTIFICATIONS: 1. APPROVED FABRICATOR OF PREFABRICATED BUILDINGS AND COMPONENTS. REFERENCE ICBO REPORT NO. FA -337 2. SBCCI COMPLIANCE REPORT NO. 9461A 3. AISC METAL BUILDING CERTIFICATION PROGRAM 4. CITY OF HOUSTON APPROVED FABRICATOR (REGISTRATION NO. 164) 5. WISCONSIN PRODUCT APPROVAL NUMBER 200231 -M 6, CLARK COUNTY, NEVADA APPROVED FABRICATOR 7. CITY OF LOS ANGELES, CALIFORNIA APPROVED TYPE 1 FABRICATOR (LA #1604) 8. CANADIAN WELDING BUREAU CERTIFICATION TO CSA STANDARD W47.1 IN DIVISION 1 (SYMBOL PY72(HOUSTON, TX)) 9. TEXAS DEPT. OF INSURANCE PRODUCT EVALUATION RC -15 APPROVAL NOTES THE FOLLOWING CONDITIONS APPLY IN THE EVENT THAT THESE DRAWINGS ARE USED AS APPROVAL DRAWINGS: A) IT IS IMPERATIVE THAT ANY CHANGES TO THESE DRAWINGS: 1) BE MADE IN CONTRASTING INK. 3) HAVE ALL INSTANCES OF CHANGE CI FART Y INDICATED. 2) BE LEGIBLE AND UNAMBIGUOUS. B) DATED SIGNATURE IS REQUIRED ON ALL PAGES. C) MANUFACTURER RESERVES THE RIGHT TO RE- SUBMIT DRAWINGS WITH EXTENSIVE OR COMPLEX CHANGES REQUIRED TO AVOID MISFABRICATION. THIS MAY IMPACT THE DELIVERY SCHEDULE. D) APPROVAL OF THESE DRAWINGS INDICATES CONCLUSIVELY THAT METALLIC HAS CORRECTLY INTERPRETED THE CONTRACT REQUIREMENTS, AND FURTHER CONSTITUTES AGREEMENT THAT THE BUILDING AS DRAWN, OR AS DRAWN WITH INDICATED CHANGES REPRESENTS THE TOTAL OF THE MATERIALS TO BE SUPPLIED BY MANUFACTURER. E) ANY CHANGES NOTED ON THE DRAWINGS NOT IN CONFORMANCE WITH THE TERMS AND REQUIREMENTS OF THE CONTRACT BETWEEN MANUFACTURER AND ITS CUSTOMER ARE NOT BINDING ON MANUFACTURER UNLESS SUBSEQUENTLY SPECIFICALLY ACKNOWLEDGED AND AGREED TO IN WRITING BY CHANGE ORDER OR SEPARATE DOCUMENTATION. MANUFACTURER RECOGNIZES THAT RUBBER STAMPS ARE ROUTINELY USED FOR INDICATING APPROVAL, DISAPPROVAL, REJECTION, OR MERE REVIEW OF THE DRAWINGS SUBMITTED. HOWEVER, MANUFACTURER DOES NOT ACCEPT CHANGES OR ADDITIONS TO CONTRACTUAL TERMS AND CONDITIONS THAT MAY APPEAR WITH USE OF A STAMP OR SIMILAR INDICATION OF APPROVAL, DISAPPROVAL, ETC. SUCH LANGUAGE APPLIED TO MANUFACTURER'S DRAWINGS BY THE CUSTOMER, ARCHITECT, ENGINEER, OR ANY OTHER PARTY WILL BE CONSIDERED AS UNACCEPTABLE ALTERATIONS TO THESE DRAWING NOTES, AND WILL NOT ALTER THE CONTRACTUAL RIGHTS AND OBLIGATIONS EXISTING BETWEEN MANUFACTURER AND ITS CUSTOMER. GENERAL NOTES THE STRUCTURE UNDER THIS CONTRACT HAS BEEN DESIGNED AND DETAILED FOR THE LOADS AND CONDITIONS STIPULATED IN THE CONTRACT AND SHOWN ON THESE DRAWINGS. ANY ALTERATIONS TO THE STRUCTURAL SYSTEM OR REMOVAL OF ANY COMPONENT PARTS, OR THE ADDITION OF OTHER CONSTRUCTION MATERIALS OR LOADS MUST BE DONE UNDER THE ADVICE AND DIRECTION OF A REGISTERED ARCHITECT, CIVIL OR STRUCTURAL ENGINEER. METALLIC BUILDING COMPANY WILL ASSUME NO RESPONSIBILITY FOR ANY LOADS NOT INDICATED. THIS METAL BUILDING IS DESIGNED WITH METALLIC BUILDING COMPANY'S STANDARD PRACTICES WHICH ARE BASED ON PERTINENT PROCEDURES AND RECOMMENDATIONS OF THE FOLLOWING ORGANIZATIONS AND CODES. 1. AMERICAN INSTITUTE OF STEEL CONSTRUCTION: "SPECIFICATION FOR THE DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" 2. AMERICAN IRON AND STEEL INSTITUTE: "SPECIFICATION FOR THE DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS" 3. AMERICAN WELDING SOCIETY: "STRUCTURAL WELDING CODE" AWS D1.1. 4. METAL BUILDING MANUFACTURER'S ASSOCIATION: "LOW RISE BUILDING SYSTEMS MANUAL" 5. INTERNATIONAL CONFERENCE OF BUILDING OFFICIALS: "UNIFORM BUILDING CODE" 6. SOUTHERN BUILDING CODE CONGRESS INTERNATIONAL "STANDARD BUILDING CODE" 7. BUILDING OFFICIAL AND CODE ADMINISTRATORS INTERNATIONAL: "BOCA NATIONAL BUILDING CODE" 8. NATIONAL BUILDING CODE OF CANADA. MATERIAL PROPERTIES OF STEEL PLATE USED IN THE FABRICATION OF PRIMARY RIGID FRAMES, AND OTHER PRIMARY STRUCTURAL EXCLUSIVE OF COLD- FORMED SECTIONS, CONFORM TO ASTM -A529 OR A -572 . FLANGES WITH THICKNESS OF ONE INCH OR LESS AND WIDTH OF 12" OR LESS CONFORM TO A -529 WITH A MINIMUM YIELD POINT OF 55,000 psi. FLANGES GREATER THAN 1" IN THICKNESS OR 12" IN WIDTH CONFORM TO A -572 WITH A MINIMUM YIELD POINT OF 50,000 psi. FLANGES WITH THICKNESS OF 2" 1 WIDTH OR LESS AND A WIDTH GREATER THAN 12" CONFORM TO 136 WITH A MINIMUM YIELD POINT OF 42,000 psi. WEB MATERIAL CONFORMS TO ASTM -A36 MODIFIED WITH A MINIMUM YIELD POINT OF 46,000 psi. OR ASTM -A1011 GR 50. MATERIAL PROPERTIES OF PIPE SECTIONS CONFORM TO ASTM -A53 TYPE E, GRADE B WITH A MINIMUM YIELD POINT OF 35,000 psi. MATERIAL PROPERTIES OF HOT ROLLED STEEL MEMBERS CONFORM TO THE REQUIREMENTS OF ASTM -A992 WITH A MINIMUM YIELD POINT OF 50,000 psi. MATERIAL PROPERTIES OF COLD FORMED LIGHT GAGE STEEL MEMBERS CONFORM TO ASTM -A1011 GRADE 55 MODIFIED WITH A MINIMUM YIELD POINT OF 57,000 psi. MATERIAL PROPERTIES OF ROOF /WALL SHEETING, BASE METAL CONFORM TO ASTM -A792 GRADES 50 OR 80 WITH MINIMUM YIELD POINTS OF 50,000 psi AND 80,000 psi RESPECTIVELY, AS REQUIRED BY DESIGN. COATING OF BASE MATERIAL IS 55% ALUMINUM -ZINC ALLOY IN ACCORDANT -E WITH AZ55 FOR UNPAINTED OR AZ50 FOR PAINTED SPECIFICATIONS. CABLE UTILIZED FOR BRACING CONFORMS TO ASTM A475. ROD AND ANGLE UTILIZED FOR BRACING MEMBERS CONFORM TO ASTM A36. STRUCTURAL JOINTS WITH A.S.T.M. A -325 HIGH STRc_NGTH BOLTS, WHERE INDICATED ON THE DRAWINGS, SHALL BE ASSEMBLED AND THE FASTENERS TIGHTENED IN ACCORDANCE WITH "TURN -OF -NUT" METHOD AS DESCRIBED IN THE SPECIFICATION FOR STRUCTURAL JOINTS USING A.S.T.M. A -325 OR A -490 BOLTS (11- 13 -85), UNLESS OTHERWISE NOTED. ALL JOINTS WILL BE ASSEMBLED WITHOUT WASHERS UNLESS OTHERWISE NOTED. ALL STEEL MEMBERS EXCEPT BOLTS, FASTENERS ANT' CABLE SHALL RECEIVE ONE SHOP COAT OF IRON OXIDE CORROSION INHIBITIVE PRIMER, MEETING THE PERFORMANCE REQUIREMENTS OF TTP -636. SHOP AND FIELD INSPECTIONS AND ASSOCIATED FEES ARE THE RESPONSIBILITY OF THE CONTRACTOR, UNLESS STIPULATED OTHERWISE IN THE CONTRACT. BUILDING DESCRIPTION: END FRAME TYPE BASIC SIZE: WIDTH LENGTH HEIGHT ROOF PITCH L RIGHT BLDG. "A" HS 60' -0 40' -0 12' -0 E.H. 2:12 (RS) NON - EXP. M. FRAME NON - EXP. M. FRAME WARNING IN NO CASE SHOULD GALVALUME STEEL PANELS BE USED IN CONJUNCTION WITH LEAD OR COPPER. BOTH LEAD AND COPPER HAVE HARMFUL CORROSION EFFECTS ON THE ALUMINUM ZINC ALLOY COATING WHEN THEY ARE USED IN CONTACT WITH GALVALUME STEEL PANELS. EVEN RUN -OFF FROM COPPER FLASHING, WIRING, OR TUBING O NTO GALVALUME SHOULD BE AVOIDED. BASE CONDITION: SHEETING: BLANK TYPE INSULATION: NO SHEETING RECESS 24 Gu ULTRA -DEK" PANEL CLASSIC GREEN ROOF NONE BY MANUFACTURER O B OTHERS EX ROOF Er WALL N A UL 26 Ga NO PANELS WALL SELF DRIL SCREWS * ZINC CA TAPE SEAL: r* TRIM: (1/8" POP RIVETS AT SPLICES) MEMBER ROOF( t+ ) STITCH ROOF( e. ) ANCHOR BOLTS 3/8" O 26 Go CLASSIC GREEN RAKE MEMBER WALL( N/A ) STITCH WALL( N/A ) BYO S 1" 26 G3 CLASSIC GREEN EAVE RAKE TO ROOF: *a RAKE TO WALL: N/A ING WARRANTIES 26 Go N/A GUTTER GUTTER TO ROOF: N/A G UTTER STRAPS: N/A MBNUBACT REf U.L. 90 No 26 Ca N/A DOWNS. CORNER TRIM: N/A R AKE ANGLE: ME MBER O 20 YR ROOF NO 26 Ga N/A CORNER PRIMARY: ® RED = GRA O GALV, 20 YR WALL I NO 26 Ca N/A ACCESS SECONDARY. ® RED 0 GRA O GALV. ** SEE MANUAL "ULTRA -DEK" CLIP: HIGH FLOATING BUILDING LOADS THIS IS TO CERTIFY THAT THIS STRUCTURE IS DESIGNED UTILIZING THE LOADS INDICATED AND APPLIED AS REQUIRED BY IBC -2000 THIS CERTIFICATION IS LIMITED TO THE STRUCTURAL DESIGN OF THE FRAMING AND COVERING PARTS MANUFACTURED BY THE BUILDING MANUFACTURER AND AS SPECIFIED IN THE CONTRACT, ACCESSORY ITEMS SUCH AS DOORS, WINDOWS, LOUVERS, TRANSLUCENT PANELS, VENTILATORS ARE NOT INCLUDED. ALSO EXCLUDED ARE OTHER PARTS OF THE PROJECT NOT PROVIDED BY THE BUILDING MANUFACTURER SUCH AS FOUNDATIONS, MASONRY WALLS, MECHANICAL EQUIPMENT AND THE ERECTION AND INSPECTION OF THE BUILDING. THE BUILDING SHOULD BE ERECTED ON A PROPERLY DESIGNED FOUNDATION IN ACCORDANCE WITH THE BUILDING MANUFACTURER'S DESIGN MANUAL, THE ATTACHED DRAWINGS, AND GOOD ERECTION PRACTICES. THE CONTRACTOR AND /OR ENGINEER OF RECORD IS TO CONFIRM THAT THESE LOADS COMPLY WITH REQUIREMENTS OF THE LOCAL BUILDING DEPT. ROOF DEAD l CAD 2.5 PSF ( FOR ROOF PANELS AND PURLINS) DRAWING INDEX COLLATERAL DEAD I OAD - PSF BASED ON TRIBUTARY AREAS: ISSUE PAGE DESCRIPTION ROOF I IVF I naD 0 -200 SQ. FT.___20PSF 0 CI of 1 COVER SHEET 201 -600 SO. FT. ---- IBC2000 (EQ. 16 -6) PRIMARY FRAMING 20 PSF OVER 600 SQ. FT.____12 PSF SECONDARY FRAMING 20 PSF 0 ES -1 INSTALLATION PROCEDURES AUXll IARY I IVF I CAD - PSF GROUND SNOW I CAD 50 PSF ( C e = 0.9 ) 0 F1 of 2 ANCHOR BOLT PLAN 0 F2 of 2 BASE E DETAILS AND REACTIONS ROOF SNOW I OAD - PSF Thermal Factor, Ct = 1.10 WIND I OAF) 90 MPH, EXPOSURE C 0 Et of 4 ROOF FRAMING PLAN SEISMIC 7 0NF - A A, 0 E2 of 4 SIDEWALL &ENDWALL FRAMING Seismic Seismic Seismic Special Response Special Response D E3 of 4 CROSS SECTION Use Site Design Aceleration at Aceleration at 0 E4 of 4 CROSS SECTION SAFETY COMMITMENT Group I Class D Cate D Short period, Ss= 58.8 % 1.- Second period, S1= 17.6 % METALLIC BUILDING COMPANY HAS A COMMITMENT TO MANUFACTURE QUALITY BUILDING COMPONENTS THAT CAN BE SAFELY ERECTED. HOWEVER, THE SAFETY COMMITMENT AND JOB SITE PRACTICES OF THE ERECTOR ARE BEYOND THE CONTROL OF METALLIC BUILDING COMPANY. IT IS STRONGLY RECOMMENDED THAT SAFE WORKING CONDITIONS AND ACCIDENT PREVENTION PRACTICES BE THE TOP PRIORITY OF ANY JOB SITE. LOCAL, STATE AND FEDERAL SAFETY AND HEALTH STANDARDS SHOULD ALWAYS BE FOLLOWED TO HELP INSURE WORKER SAFETY. MAKE CERTAIN ALL EMPLOYEES KNOW THE SAFEST AND MOST PRODUCTIVE WAY OF ERECTING A BUILDING. EMERGENCY PROCEDURES SHOULD BE KNOWN TO ALL EMPLOYEES. DAILY MEETINGS HIGHLIGHTING SAFETY PROCEDURES ARE ALSO RECOMMENDED. THE USE OF HARD HATS, RUBBER SOLE SHOES FOR ROOF WORK, PROPER EQUIPMENT FOR HANDLING MATERIAL, AND SAFETY NETS WHERE APPLICABLE, ARE RECOMMENDED. RAIN FALI INTENSITY IS EQUAL TO 4 INCHES PER HOUR FOR A 5 MIN DU A110N (F YEAR MEAN RECURRCNCCI Basic Estructural System Ordinary Moment Frames (OMRF), R= 4.0 00 =3.0 IMPORTANCF FACTORS WIND LOAD 1.0 SNOW LOAD 1.0 Response Modification Factor (R) SEISMIC LOAD 1.0 Deflection Amplification Factor (Cd) Analysis Procedure - Equivalent Lateral Force M 77ANIN GADS LIVE LOAD N/A PSF DEAD LOAD N/A PSF CRANE INFORMATInN N/A 1 0 1 S -1 to S -4 I STANDARD DETAILS NOTES _ _ 7 ROOF SNOW LOAD HAS BEEN UTILIZED FOR DETERMINATION OF SEISMIC DESIGN FORCES. DRAWING STATUS FOR APPROVAL NO. DATE THESE DRAWINGS, BEING FOR APPROVAL, ARE BY DEFINITION NOT 0 FINAL, AND ARE FOR CONCEPTUAL REPRESENTATION ONLY. THEIR PURPOSE IS TO CONFIRM PROPER INTERPRETATION OF THE PROJECT - 0 11 DOCUMENTS. ONLY DRAWINGS ISSUED "FOR CONSTRUCTION" CAN BE CONSIDERED AS COMPLETE. FOR PERMIT THESE DRAWINGS, BEING FOR PERMIT, ARE BY DEFINITION NOT FINAL IN THAT, AS A MINIMUM, PIECE MARKINGS ARE NOT IDENTIFIED. ONLY DRAWINGS ISSUED " FOR CONSTRUCTION " CAN BE CONSIDERED AS COMPLETE. [: fl FOR f.ONSTRN('TION� FINAL DRAWINGS. OVERALL PROJECT. DESCRIPTION BY CK'D metallic building company FOR CONSTRUCTION FOR CONSTRUCTION ZAV DVB ZIP FAIRVIEW •HOUSTON, TEXAS • P.O. BOX 40338 ZIP 77041 (713) 466 -7788 ZIP 77240 DESCRIPTION COVER SHEET SIZE SEE BUILDING DESCRIPTION AB _ CUSTOMER TRI -STEEL CONSTRUCTION CO. INC. _ SAME _ LOCATION REXBURG ID. 1 CAD BY LFC ORN. BY CK D BY DATE SCALE JOB NO. PH BLDG,DESC. SHEET NO ISSL NONE 3305 - 220165 A Cl of 1 0 0500158 Steele Line 1365 S 12th W In order to give you prompt services and keep problems to a minimum, please handle any shortages or back charges in the following manner: Carefully check your packing list while unloading. Mark any items, which appear to be missing and notify the Customer Service Deportment at 1 -800- 777 -9378 as soon as possible. Calling someone else could delay the proper response. I. SHORT MATERIALS - Immediately upon delivery of material, quantities are to be verified by the Customer against quantities that are billed on the shipping document. Neither the Manufacturer nor the carrier is responsible for the material shortages against the quantities billed on shipping document if such shortages are not noted on shipping documents when the material is delivered, and then acknowledged by the carrier's agent. If the carrier is the Manufacturer, claims for shortages are to be made by the customer to the common carrier. If the material quantities received are correct according to the quantities that are billed on the shipping documents, but are less than the quantities ordered or the quantities that are necessary to complete the metal building according to the Order Documents, claim is too be made of the Manufacturer. IL DAMAGED OF DEFECTIVE MATERIAL - Damaged or defective material regardless of the degree of damage, must be noted on the shipping documents by the Customer and acknowledged in writing by the carrier's agent. The Manufacturer is not responsible for material damaged in unloading of packaged or nested materials, including, but not limited to: fasteners, sheet metal, "C" & "Z" sections & covering panels that become wet and /or damaged by water while in the possession of others. Packaged or nested material that becomes wet in transit must be unpacked, unstacked and dried by the Customer. If the carrier is the Manufacturer, the Customer must make claim for damage directly to the Manufacturer. If the carrier is a common carrier, the Customer must make the claim for damage to the common carrier. The Manufacturer is not liable for any claim whatsoever including, but not limited to labor charges of consequential damages resulting from the Customer's use of damaged of defective materials that can be detected by visual inspection. III. EXCESSIVE MATERIAL The Manufacturer reserves the right to recover any material delivered in excess or those required by the Order Documents. IV, INITIAL CLAIM - In the event of error the Customer must promptly make a written or verbal "Initial Claim" to the Manufacturer for the correction of design, drafting, Bill of Materials of fabrication error The "Initial Claim" includes: 1. Description of the nature and extent of the errors, including quantities. 2. Description of the nature and extent of proposed corrective work including estimated man - hours. 3. Material to be purchased from other than the Manufacturer, including estimated quantities and cost. 4. Maximum total cost of proposed corrective work and material to be purchased from other than the Manufacturer. ES01 In Orden de darle on mejor servicio y reducir los problemos at minima, par favor dingla cuolquier falla o exceso de material de to siguiente manero: Cheque cuidadosomente sus paquetes mieniras son descargados. Marque cualquier objeto que parezco no encontrarse, si asi es, Rome y notifique al Departamento de Servicio at cliente el numero es 1- 800 -777 -9378 tan pronto como le sea posible. Llamando podria ahorrarse tiempo at encontor un responsable de la folta de material. 1. FALTA DE MATERIAL - Inmediatamente despues de to entrego del material, el cliente debe verificar que sus cantidades seen los mismas que aparecen facturadas en to Orden de compra. Ni el fabricante , ni el transportisto son responsobles del material foltante que aparece facturado en el recibo, si la folta es rich icado en el documento cuando el material es entregado y es admitido par el transportista. Si el trans ortista es el fabricante las r ue as fa to de material reran hechas or el cliente e tr p q j par p me a l ansporfista. Si las cantidades de moteriales recibidos son correctos de acuerdo a las cantidades facturadas en to recibo , pero el material ordenado es menos del requerido para completer la construccion de acuerdo a la Orden de compra, las quejas seran hechas at fabricante. II. MATERIAL DANADO 0 DFFECTUOSO - Material donado a defectuoso, de acuerdo al grado defectuosidad en que se encuentre, debe ser notificado en el recibo par el cliente y admitido par escrito par el transportista. El fabricante no se hose responsable par el material donado en to descargo de los paquetes o mientras estos son empocados, inluyendo, pero no limitodo solo a eso, fasteners, laminas , secciones de "C" y "Z" y cubiertas que se Trojan o donan par el aqua mieniras se encuentron en posesion de olros. Material empocado que se moje mienras se troslada, debero ser desempocado, separado y secado par el cliente. Si el fabricante es el transportsto, el cliente debero hater la queja par defectuosidad directomente at fabricante. Si el transportisto es el agente transportisto o el encorgado del translado del moterial, el cliente debero baser to queja al antes mencionodo. El fabricante no es responsable de ningun tipo de queja, no se limits a los danos consecuentes resultado del use de material donado o defectuoso par el cliente ,si esas danos son detectodos par inspeccion visual. III. MATERIAL EN EXCESO - El fabricante se reserva el derecho de recover o recobror cuolquier material que foe entregodo en exceso de acuerdo at requerido en to Orden de compra. IV. OUEJA INITIAL - Al percatarse del error el cliente rapidamente debero hater, ya sea par escrito 0 verbal Una queja inicial at fabricante porn to correcion del diseno, dibujo, facturacion del material o error de fabrication. Lo queja inicial incluye: i. Lo description de to noturolezo y grado de error, incluyendo contidades. 2. Description de to naturalezo y el grado de correcion del trabajo propuesto, incluyendo estimation hombre -horn. 3. Material que sera comprodo a otro que no sea el fabricante, incluyendo cantidades estimadas y costos. 4. Costo total maximo propuesto de la correcion del trabajo y material que sera comprodo a otro que no sea el fabricante. ES01 AUTHORIZATION FOR CORRECTIVE WORK If the error is the fault of the Manufacturer, an "Authorization for Corrective Work" must be issued in writing by the Manufacturer to authorize the corrective work at a cost not to exceed the maximum total cost set forth. Alternative corrective work other than that proposed in the "Initial Claim" may be directed by the Manufacturer in the "Authorization of Corrective Work." Only the Customer Service Department may authorize corrective work. y. FINAt CLAIM - The 'Final Claim" in writing must be forwarded by the Customer to the Manufacturer within ten (10) days of completion of the corrective work authorized by the Manufacturer. The "Final Claim" must include: 1. Actual number of man –hours by date of direct labor use on corrective work and actual hourly rates of pay 2. Taxes and insurance an total actual direct labor. 3. Other direct costs on actual direct labor. 4. Cost of material (not minor supplies) authorized by the Manufacturer to be purchased from other than the Manufacturer, Including copies of paid Invoices. 5. Total actual direct cast of corrective work (sum of 1, 2, 3 & 4). The "Final Claim" must be signed and certified true and correct by the Customer. "Final Claims" are credited to the Customer by the Manufacturer in on amount not to exceed the lesser of the maximum total cost set forth in writing in the "Authorization for Corrective Work" or total actual direct cost of corrective work. 6. Cost of equipment (rental or depreciation), small tools, supervision, overhead and profit are not subjected to claims. VI. STRU FRAMING SHOP PRIMER The Primers supplied by NCI are not intended to provide the uniformity of appearance of a finish coal nor to provide extended protection if subjected to prolonged exposure. If immediate erection of steel is not possible, it must be protected from exposure to atmospheric and /or environmental conditions that may be detrimental to paint performance. These conditions would include, but not be limited to, prolonged exposure to ultra - violet light due to possible fading and or spotting or standing water resulting in spotting, peeling or localized surface oxidation. The MBMA Commentary states that: "...the manufacturer is not responsible for the deterioration of the shop coat of primer or corrosion that may result from exposure to atmospheric and environmental conditions, nor the compatibility of the primer to any field applied coating... The AISC, Code of Standard Practice further states that: "...the shop coat of paint is the prime coat of the protective system. It protects the steel for only a short period of exposure... Primer touch -up due to transit abrasions and /or scratching during loading and unloading is to be expected. Primer touch -up is not the responsibility of NCI. Additional guidelines for the handling and storage of steel components can be found in both the MBMA Commentary and the ASC Code of Standard Practice. VIL SHIPMENT ARRIVAL TIME – Every effort will be made to see that the carrier arrives at the jobsite on the requested day and at the requested hour. Manufacturer makes no warranty and accepts no responsibility for costs associated with a shipment not arriving at a requested time unless a separate agreement has been made in writing for a guaranteed arrival time. ES02 S TRUCTURAL - A great amount of time and trouble can be saved if the building parts are unloaded at the building site according to a pre- orronged plan. Proper location and handling of components will eliminate unnecessary handling. NOTE: Piece marks are stenciled on primary structural members at lower end, V -0" from end. Inspect all shipments prior to releasing the tie –downs for loads that may have shifted during transit! REMEMBER, SAFETY FIRST( Blocking under the columns and rafters protects the splice plates and the slab from damage during the unloading process. It also facilitates the placing of slings or cables around the members for later lifting and allows members to be bolted together into sub - assemblies while on the ground. Extra care should always be exercised in the unloading operation to prevent injuries from handling the steel and to prevent damage to materials and the concrete slab. DRAINAGE ELEVATE TARP —;— AIR CIRCULATION If water is allowed to remain for extended periods in bundles of primed parts such as girts, purins, etc., the pigment will lade and the paint will gradually soften reducing its bond to the steel. Therefore, upon receipt of a job, all bundles of primed parts should be stored at an angle to allow any trapped water to drain away and permit air circulation for drying. Puddles of water should not be allowed to collect and remain on columns or rafters for the same reason. The coat of shop primer is intended to protect the steel framing for only a short period of exposure to ordinary atmospheric conditions. The coat of shop primer does not provide the uniformity of appearance, or the durability and corrosion resistance of a field applied finish coat of paint over a shop primer. The Manufacturer is not responsible for deterioration of the shop coat of primer or corrosion that may result from exposure to atmospheric and environmental conditions, nor the compatibility of the primer to any field applied coating. Minor abrasions to the shop coat caused by handling, loading, shipping, unloading and erection after painting are unavoidable. ES03 UESGARGA, MANED Y ALMACEN DE MATERIAL ESTHUCTURA - Una gran contidad de tiempo y problemas pueden ahorrarse si las piezas son descargodas en el lugar de to construccion de acuerdo a on plan pre arreglado. Lugar y manejo apropiado de los componentes eliminaron monejos o movimientos inecesarios. NOTA Jos pezas deberan ester marcadas en los demenlos principales de to estructura en to parte inferior de Jos mismos, a l' -0" del final. Inspeccione primeramente todos los emborques antes de descargar y desatar los elementos ya que pudieron haberse movido durante el recorrido. B£Ctl£BO£ S£6UB1DAD £S Pk1xl£NO Las separaciones o calzas de madera que se colccan bajo Jos columnar y rafters evitan un dano en las planchas de coneccion al descargar los materiales. Esto tombien facilita to localization de slings o cables alrededor de los miembros Para despues levantor y permitir a Jos miembros ser atornillados juntos dents de sub- montojes, mieniras estan en tierra. Extra- cuidodo debero ser siempre aplicado en la operation de descargo Para prevenir danos par el manejo del acero asi como porn prevenir donor Jos materiales y el concreto. DRENAR rte' ELEVAR CUBIERTA / ` ° - CIRCULACION DE AIRE Si el aguo puede permanecer par periodos considerables en nervaduras o hendiduras de las portes principoles como girts, purlins, etc. el pigmento follara y to pinturo se suavizaro groduatmente reduciendo to union con el acero, par to tonto recibido el material todos as hendiduras de estos piezas deberon ser almocenados en un angulo que permits que cuolquier aqua Puerto drenarse y permitir to circulation de aire Para secorse. No debera permitirse que el aqua se colocte y estanque en los columnas y rafters par to misma razon . Lo capa de shop primer intenta proteger at marco de acero par on determinado tiempo de exposition a condiciones atmosfericas ordinarias. Lo capa de shop primer no proporciona uniformidad de apariencia, durabilidad y resitencio a la corrosion como one capa final de pintura hecha en el compo sabre el shop primer. El fabricante no se responsobiliza del deterioro de to cape de de primer o de to corrosion que puede resultor de la exposition a las condiciones otmosfericas y of media ambiente, ni to compatibilidod del primer a cualquier capa de pintura oplicado en to obra. Menores abrosiones de to ultima capa cousadas par monejo, cargo, embarque, descargo y erection del material despues de la Jointure son inevitables. Retoques de estas abrosiones menores son responsabilidad del cliente final. El acero primario el cual es almacenado en to obra durante la erection del edificio, debero mantenerse libre de tierra asi como en on ES03 Touch -up of these minor abrasions is the responsibility of the End Customer. Shop primed steel which is stored in the field pending erection should be kept free of the ground, and so positioned as to minimize water - holding pockets, dust, mud, and other contamination of the primer film. Repairs of damage to primed surfaces and /or removal of foreign material due to improper field storage or site conditions are not the responsibility of the Manufacturer. All primer should be touched up as required before erection! Manufacturer's wall and roof panels including color cooled, galvalume & galvanized, provide excellent service under widely varied conditions. All unloading & erection personnel should fully understand that these panels oie quolity merchondlse, which merits cautious core in handlinq . Under no circumstance should panels be handled roughly Packages of sheets should be lifted off the truck with extreme care taken to insure that no damage occurs to ends of the sheets or to side ribs. The packages should be stored off the ground sufficiently high to allow air circulation underneath the packages. This avoids ground moisture & deters people from walking on the packages. One end of the package should always be elevated to encourage drainage in case of rain. All stacked metal panels are subject, to some degree, to localized discoloration or stain when water is trapped between their closely nested surfaces. NCI exercises extreme caution during fabricating and shipping operations to insure that all panel stock is kept dry. However, due to climatic conditions, water formed by condensation of humid air can become trapped between stacked sheets. Water can also be trapped between the stacked sheets when exposed to rain. This discoloration caused by trapped moisture is often called wet storage stain. The stain is usually superficial & has little effect on the appearance or service life of the panels as long as it is not permitted to remain on the panels. However, moisture in contact with the surface of the panels over an extended period can severely attack the finish & reduce the effective service life. It is imperative that all panels are inspected for moisture upon receipt of the order. If moisture is present, dry the panels at once & store in a dry, warm place. CAUTION: Care should always be token when walking on panels. Use safety lines and nets when necessary! Panels are slippery. Oil or wax applied to the roof & wall panels for protection against weather damage will make them a very slippery surface. Wipe dry any oil that has puddled from bundles stored on a slope. Dew, frost, or other forms of moisture greatly increase the slipperiness of the panels. Always assume panel surface is slippery & act accordingly. Never walk or step on skylights or translucent panels! Think safely!! Use wood blocking to elevate & slope the panels in a manner that will allow moisture to drain. Wood blocking placed between bundles will provide additional air circulation. Cover the stacked bundles with a tarp or plastic cover leaving enough opening at the bottom for air to circulate. When handling or uncrating the panels, lift rather than slide them apart. Burred edges may scratch the ESO4 sitio con minima aqua, polvo , lodo y otros contominantes que afecten la primers cape. Reparaciones de danos a to primera superficie y/o to elimination de materiales ajenos a estos ,debido of incorrecto almocenamiento en obm o a las condiciones del lugar no son responsabilidad del fabricante. Todo acero primario debero ser retocado como se requiero antes de la construccion Cubiedas de Techos y Paredes Paneles de paredes y techos del fabricante incluyendo capa de color galvalume y golvanizado proporciona un servicio excelente bajo Una extensa variedad de condiciones. Todo personal de descargo y erection de material debero entender completamente que estos paneles son pioductos de calidod , los cuoles amenton cuidodo of manejorse. Bola ninguna circunstancia d b a monejarse de manera aspen a accidentado Los paquetes de lamina deben ser levantodos del carrion con extremo cuidado asegurandose que ningun dano ocurra , ni a las un p tar ni a las nervoduras de las mismas.los paquetes deberan almacenorse to suficientemente alejados de to superficie de tierra pora permitir to circulation de aire bajo los paquetes, esto evita la humedod de la tierra e impide que to genie amine sabre los paquetes. Una de las extremos del paquete de laminas debero ester siempre elevado pars drenor el aguo en caso de Iluvia Todo paquete o monton de paneles metal estan sujetos en aigun grado a sufrir ciertas decoloraciones o manchas cuando el ague esto atropodo entre sus superficies mas cerconas. NCI provee extreme precaution durante to fabrication y el periodo de embarque asegurandose que todo panel apilodo se mantengo seco. De cualquier manera debido a !as condiciones climaticas y a to condensation de aire hurredo , el aqua puede quedarse atropodo entre las laminas apiladas y to mismo sucedera si estos se exponen a la Juvia. Lo decolarocion cousodo par to humedod atrapado es frecuentemente Ilamada mancha de humedod guardada. Lo mancho es usualmente superficial y tiene un pequeno efecto en to oporiencia o duration del panel siempre y cuando no se permits que In mancho permanezca en el panel. De cualquier manera el contacto de to humedod con to superficie de los paneles durante on periodo largo puede donor severamente el acabodo y reducir to duration de villa. Par to tanto es necesori que todos los paneles sean inspeccionodos par humedod al recibir el embarque. Si se presents humedod procedo a secar los paneles inmediatomente y almocenelos en un lugar seco y colido. PRECAUCION: Siempre debe tenerse cuidado cuando se amine sabre los paneles, use redes y lineal de seguridad cuando sea necesariH Los paneles son resbaladizos. Aceite o sera oplicados a los paneles del fecha a Paredes Para protegerlos contra danos cousados por el ciima los haran superficies muy resbaladizas. Seque cualquier aceite que se pudo haberse acamulodo par aimacenarse en declive. Rocio, hielo o cualquier otra forma de humedod ineremento que las superficies de los paneles se vuelvan mas resbaladizos. Asuma siempre que to superficie del panel es resbaloza y acfue de ocuerdo a esto. Nunca pise o amine sabre skylights a paneles tronslucidos, Piense seguro!!!!!!! Use bloques de madera Para elevar a inclinor los paneles de manera que permits drenar to humedod. Colzos de madera entre las picas ce paneles permitiro circulation de aire adicionol. Cubra las picas con una cubierta plostica dejando suficientemente obierto el Tondo pars permitir to circulation de afire. Cuando se manejan o separen los paneles, no los deslize de manera que se separen mejor levantelos, el sobrante en los orillas podria rallor Ins superficies cuando las laminas se deslizon separandose Una ESO4 coated surfaces when sheets are slid over one another. Never allow panels to be walked on while on the ground. Rough & improper handling of a panel is inexcusable & a prime example of poor job supervision. Correct fastener installation is one of the most critical steps when installing roof panels. Drive the fastener in until it is tight and the washer is firmly seated. Do not overdrive fasteners. A slight extrusion of neoprene around the washer is a good visual tightness check. Always use the proper tool to install fasteners. A fastener driver (screw gun) with a RPM of 1700 -2000 should be used for self - drilling screws. A 500 -600 RPM fastener driver should be used for self- tapping screws. Discard worn sockets, these can cause the fastener to wobble during installation. 9;;U P: �� :__ CORRECT DEGREE OF TOO TIGHT TOO LOOSE NOTE S LIGH T IGHTNE OF SEALANT SQUEEZED TOO THIN SEALANT IS NOT SEALANT EXTRUDES FAR BEYOND COMPRESSED TO FASTENER FEAD FORM SEAL NOTE: Aiwa remove emove metal filings from surface of panels at the end of each work period. Rusting filings can destroy the ,JA ST finish SEALANT warranty. Proper mastic application is critical to the weather tightness of a building. Mastic should not be stretched when installed. Apply only to clean, dry surfaces. Keep only enough mastic on the roof that can be installed in a day. During warm weather, store mastic in a coal dry place. During cold weather (below 60') mastic must be kept warm (60' -90') until application. After mastic has been applied, keep protective paper in place until panel is ready to be installed. ALIGNING THE GIRTS Installation of the building walls is generally done before the roof. Before starting the wall installation, check to be sure that the eave strut and girts are straight and plumb. One method of aligning the girts is to cut temporary wood blocking to the proper length and install between the lines of girts. This blocking can be moved from bay to bay which will reduce the number of pieces required. Normally, one line of blocking per bay will be sufficient. Bonding can also be used to hold the girts straight and plumb. NOTE: Temporary girt blocking is not recommended on concealed fastener panels. The removal of the blocks after panel installation will cause oil canning. FRAME STRUT —,,/ ES05 WOOD BLOCKING de otra. Nunca permits que pisen sabre los paneles mien Is estan sabre tierra. Un rudo e inapropiodo manejo de JOS paneles es imperdonoble y on buen ejemplo de male supervision de trabajo. INSTA A .ION DE HAS Lo correcto colococion de pijas es one de los pesos mas mportantes en la instalocion de un techo. Gire la pija haste que este opretado y to arandela o washer este firmemente asentada. No sobregire o opriete en exceso las pijas. Para shear de manero de visual que los elementos esten correctamente colocados use Una sellador de neopreno alrededor de to orendela. Siempre use las herramientas opropiodas pars instalar pijas. Un destornillador electrico con on RPM de 1700 -2000 debero utilizarse pars self - drilling screws. Un 500 -600 tornillodor se usam en el caso de Jos pijas self- taping. Descarge y remueva Jos empoques usados en el atornillador, estos pueden causar que to pieta tien a Traverse a mantenerse inconstante durante to instalocion. _ LQ LLD W 0 Tff = T BANGULO CORRECTO MUY AJUSTADO MUY HOLGADO DE AJUSTE EL SELLADOR ESTA MUY APRETADO Y EL SEUADOR NO ESTA NOTE EL DEL GADO SOBRESALE FUERA DE FUERA DE LA COMPRIMIDO PARA FORMAR CIRCULO DE SELLADOR CABESA DE U% PIJA EL SELLO NOTA! Siempre remueva las limaduras de metal que quedan sabre la superficie de los paneles al final de cads periodo de trabajo. Las limaduras pueden destruir el ocabodo final y anular cualquier garantio. SELLAD AD OR Lo apropiado oplicocion del sellador es de gran importoncio en to impermiabilidad de un edificio. EI sellador no debe estirarse cuando se esto instolando. Aplique solomente sabre superficies limpias y secas. Mantenga solamente to contidad de sellador que se colocara ese dia. Durante clama colienle, olmacenelo en un lugar f6o y seco. Durante clima f6o (abajo de 60' el sellador debe mantenerse caliente (60' -90') hasta su oplicacion. Despues de que el sellador hallo side oplicado, mantengo to cubierta o papel protector haste que el panel este listo porn instalorse. ALINIAMIENTO DE LOS AMARRES Lo instalocion de las Paredes de el edificio es generalmente hecho antes que el techo. Antes de empezor con to instalocion de los poredes, asegurese que el olero y el amarre esten erguidos y nivelados. Un methoo porn alinear los amarres es cortor calzas de manero del mismo largo de los amorres estas estaron temporalmente instaladas entre los ellos . Estes bloques de madera podron ser removidos de Una bohio y vueltos a user en otra to cuol reduciro el numero de piezas requeridas. Normalmente, uno linea de bloques de madera par bohia serion suficiente. Estas ataduras podran ser solo usadas porn mantener o sostener los amarres rectos y nivelados. NOTA! Calzas o bloques de madera temporales entre los amorres no son recomendables en paneles con pijas ocuitas. El movimiento de estos bloques despues de to instalocfon del panel podria causar hendiduras en los amarres. 1\ — ES0 ALLTORIZACION PARA C.ORRECCION OF TRABAJOS – Si el error es culpa del fabricante, Una autorizacion Para correcion de trabajo, debero ser emitida en escrito par el fabricante , Para autorizar to correcion siempre y cuando no excedo el costo total maxima esfablecido. El fabricante en to autorizocion de correcion de trabajo, puede corregir el trabajo de acuerdo y solamente en to estoblecido en la queja inicial, El Departamento de Servicio al cliente es el unico que puede outorizar la correcion de on trobojo. V OUEJA FINAL - La queja final escrito debe ser enviada par el cliente at fabricante con 10 Bias de anticipocion antes de completer to correcion del trabajo. Lo queja final incluye: 1. Numero real de hombre -horns par fecha de trabajo directo usadas en corregir el trabajo y pago real de porcentoje de horns. 2. Impuestos y aseguranza real y total del trabajo 3. Otros costos directos, de trabajo real directo 4. Costo del material (no suplementos menores) autorizacion del fabricante Para compror a otro que no sea el mismo. Incluyendo copies de facturas. 5. Costo real directo total de trabajo corregido (incises 1,2,3,4,5). La queja final debera ser firmado y certificada verdadero y correctamente par el cliente. Quejas finales son acreditados at cliente par el fabricante en uno contidad que no excedo el minima de costo total maximo esfablecido y inscrito en la autorizacion de correcion de trabajo a costo total real directo de trabajo corregtoo. 6. Costo del equipo (olquiler o depresiocion) herramientas pequenos, supervision, pequenos sobregiros y beneficios no sujetos a quejos. VLMARCO ESTRUCTURAL (SHOP PRIMER) - Los primers que NCI provee no intentan proporcianor una apariencia uniforme como to horio una capa final de pintura ni tampoco pretende una protection excesiva especialmente si el material se expone prolongadamente al media ambiente. Si la erection del acero no es posible inmediotamente, debe protegerse a to expocision de las condiciones atomosfericas y/o ambientoles que podrian perjudicar el funcionomiento de la pintura. Estas condiciones induran, pero no se limitaron solo a las condiciones antes mencionadas to exposition prolongodo a to luz ultrovioleto puede producir destenimiento o monchas y to ocumulacion de aqua, manchos, coida de to pinturo y oxidocion en ciertas superficies. Lo MBMA declare: "...el fabricante no es responsable del deterioro de to capa de primer o la corrosion que resulte de to exposition a la atmosfera y a las condiciones ambientales, ni tompoco a to (alto de compatibilidad del primer con cuolquier otro capa de pintura oplicadc en obro..." Lo AISC. Codigo de las practices standar dice: "...la colon de pintura primer es la primers capa del sistema de protecction. Este protege el Otero par un corto periodo a to exposition..." Debe esperarse que retoques de pinturas seen necesorios debido a la abrasion y/o ralloduras que se produzcon durante el proceso de cargo y descargo. Estos retoques no son responsabilidad de NCI. Guios adicionoles del manejo y almocenamiento de los componentes de acero pueden ser encontrodas en Comentanos del MBMA asi como en el AISC Codigo de practices standar. VII. HORA OF LL FGADA D MBARO I - Se hara on esfuerzo par logror qu el transportisto Ilegue at lugar de trabajo el die y a to hors solicitada. El fabricante no garontiza y no acepto ninguna responsabilidad par el costo osociado con el embarque que no Ilegue a la hora solicitodo excepto, que on arreglo se holla hecho par separodo, garantizando la hora de Ilegoda. ES02 NOTE: 1. These Installation Procedures are intended to depict general installation as described above. Consult your installation manual or additional NS– Sheets for further clarifications. NOTA: 1. Estos Procedimientos de Instolocion describir de manero general to instalocion de el objeto coma se menciona arriba. Consulte su manual de instalacon o sus Nuevos Dibujos Standort Para uno presentation mas tiara. AMARRE MADERA REMSIONS N O. O Fl- FOR — CONSTRUCTION ZAV DVB B C n JU \:., n P Customer: TRI -STEEL CONSTRUCTION CO. INC. End User: SAME Location: REXBURG, D. Det. By Chk By Date Scale Building ID dab Number Sheet Number Issue N.T.S. 3305 - 220165 1 ES -1 I 0 N NI 0 o� _t o� i t N 0 t I A i ( P A Z-',,— i t A o N q QI N 40' -0 0/0 STEEL 18' -s I () - .o Io t ANCHOR BOLT SETTING PLAN i ALL BASE PLATES AT ELEVATION 0' -Q" UNLESS NOTED. 18'•-3 ANCHOR BOLT DIAMETERS HAVE BEEN DESIGNED BY THE METAL PROJ DRAW NG STATUS 40' -0 0/0 STEEL 18' -s I () - .o Io t ANCHOR BOLT SETTING PLAN ALL BASE PLATES AT ELEVATION 0' -Q" UNLESS NOTED. ANCHOR BOLT DIAMETERS HAVE BEEN DESIGNED BY THE METAL PROJ DRAW NG STATUS BUILDING MANUFACTURER BASED ON AISC METHOD WITH COMBINED ANCHOR BOLT PROJECTION DIA. SHEAR AND TENSION. FnR APPRAVAI• THESE DRAWINGS, BEING FOR NO. DATE DESCRIPTION ANCHOR BOLT 1/2" 1 1 / 2 " APPROVAL, ARE BY DEFINITION NOT FINAL, AND ARE FOR CONCEPTUAL REPRESENTATION ONLY. THEIR 0 10 /26/04 FOR CONSTRUCTION DEVELOPMENT, EMBEDMENT AND HOOK LENGTH OF ANCHOR BOLTS ' " 5 /8" 2" PURPOSE IS TO CONFIRM PROPER INTERPRETATION OF THE PROJECT IN THE CONCRETE ARE DESIGN RESPONSIBILITY OF OTHERS. ALSO a BOTTOM OF 3/4" 2 1/2" DOCUMENTS. ONLY DRAWINGS ISSUED "FOR CONSTRUCTION" CAN BE DESIGN OF SHEAR ANGLES, TENSION PLATES, HAIRPINS, AND ANY OTHER EMBEDDED MATERIAL IN THE CONCRETE SHALL a BASE PLATE ` 7/8" 3 1/2" CONSIDERED AS COMPLETE. FC1R PERMIT• BE DESIGNED a a ° 1" 3 1/2" , FIN DRAAS AND PROVIDED BY OTHERS, ',: • t 1/8" 3 1/2" A UM, P ECE ERMIT, MARKINGS ARE NOT I DEFINI TI ON iN TSH NTINOT ONLY DRAWINGS ISSUED " FOR CONSTRUCTION " CAN BE CONSIDERED AS 9011_ ANCHOR BOLT PROJECTION IS FROM BOTTOM OF BASE PLATE. - ' 1 1/4" 3 1/2" X COMPLETE. Eaz_ rnwas?uCnnn- FINaL DRAWINGS. ANCHOR BOLTS BY OTHERS metallic building company 7301 FAIRVIEW -) HOUSTON, TEXAS • P.O. BOX 40338 ZIP 77041 (713) 466 -7788 ZIP 77240 DESCRIPTION ANCHOR BO PLAN SIZE SEE BUILDING DESCRIPTION SHEET Ct CUSTOMER TRI -STEEL CONSTRUCTION CO. INC. SAME LOCATION REXBURG, ID. Y LFC DRN. BY D BY DATE SCALE J08 NO.� PH BLDG. SHEET NO, ISSUE NONE 3305- 220165 1 4r F1 Of 2 0 16� -s -s _ i I 2 1/2" CL c o r� Ll c m vs a Addlell, mini side 1 3, room r"ired 5/8" Dia, W / washer 3 �F w rctth ,B•4 - sheeting notch n dt h if required QTY. I.D. width Re marks ONE 0 7' x 7' O.H. DOOR (B OT HERS) FI LOCATED A negative value, indicates If opposite direction Front Sw Front SW 8 Back SW Hor + f Hor + Ba se Pl D etail _ A _ Base Plate Detail B Base Plate Detail Framed Opening Framed Opening A. Bolts 3 4 Base PL Thk. 3/8' A. Bolts 3/4 "� Base PL Thk. 3/8 A. Bois 5/8 Base PL Thk. 1/4 C A. Bolts 5 8'1� Bose PL Thk. 1/4" Base Detail Notice: A minimum of 1/4" space should be allowed from the sheet end to any surface. 3" Mox -• Steel Line /� Fin. Floor C d 4 a d A q . Steel Line Wall Panel Member Screw 12 -14 x 1 1/4" at 12° O.C. R d OazecLAalLS=haa I SEC. B I �1111r11 V1 Not by Bldg.Mfg. h� ! Base Angie /-Finished Floor �) I ps Notice: Base Trim [ Ifinsulotion is req'd install trim first. Base aIe Scapa w/o Panel Recess w/ Base Trim SEC 4 DL + LL DL + Wt. INTERIOR COLUMNS 2 ,86 10 SEISE 175 5.77 K 14.5 K 5.1 K PORTAL FRAME REACTIONS at LINE A & d 0.9 DL + Em /1.4 DRAWING STATUS FOR APPROVAi THESE DRAWINGS, BEING FOR APPROVAL, ARE BY DEFINITION NOT FINAL, AND ARE FOR CONCEPTUAL REPRESENTATION ONLY. THEIR PURPOSE IS TO CONFIRM PROPER INTERPRETATION OF THE PROJECT DOCUMENTS. ONLY DRAWINGS ISSUED "FOR CONSTRUCTION" CAN BE CONSIDERED AS COMPLETE. FOR PFRMIT- THESE DRAWINGS, BEING FOR PERMIT, ARE BY DEFINITION NOT FINAL IN THAT, AS A MINIMUM, PIECE MARKINGS ARE NOT IDENTIFIED. ONLY DRAWINGS ISSUED " FOR CONSTRUCTION " CAN BE CONSIDERED AS COMPLETE. F R FOR CONCTRl1r:TION: FINAL DRAWINGS. DA _ DESCRIPTION _ /26/04 FOR CONSTRUCTION Main Frame Reactions at Unes: 1 AND 3 (NON -EXP FRAMES) C , " \ NOTE: D �J All reoctbns are shown in Kips A negative value, indicates If opposite direction Front Sw Front SW Rack SW Back SW Hor + Hor + Hor + Hor {`\ Mom + Mom + +� y + Idom i y Condition Grfd Ver Hor Mom DL A 1.8 1.1 0.0 OL 0 1.8 -1.1 OA DL + LL A 8.8 5.9 0.0 BL + LL D 118 -5.9 0.0 OL +S. A 119 9.5 0.0 OL + SL D 119 -9.5 0.0 OL + UBL A 9.2 9.5 0.0 BL + UBL 0 18.7 -9.5 0.0 DL + UBR A 18.7 9.5 0.0 OL + UBR D 9.2 -9.5 0.0 0,6 + WLL A -3.6 -24 0.0 0.6 + WLL D -2.1 1.2 0.0 0.6'01. + WL2 A -1.8 -1.4 0.0 0.6 + WI-2 D -0.4 0.3 0.0 0.6 + WLR A -2.1 -1.2 0.0 0001. + WLR 0 -3.6 14 0.0 0.6"DL + WR2 A -0.4 -0.3 0.0 0.6 + WR2 D -1.8 1.4 0.0 DL + 0.7571. + 0.75 *WLL A 3.6 2.5 0.0 DL + 0.75*LL + 0.75*WLL 0 4.6 -3.3 0.0 OL + a75*% + 0.75 *WLL A 7.4 5.1 0.0 01. + 0.75"5. + 0.75*WLL D 8.5 -6.0 0.0 DL + 035*U8L + 0.75 *WLL A 18 5.1 0.0 OL + 0.75*UBL + 0.75 *WLL D 111 -6.0 0.0 DL + 0.75"UBR + 0.75*WLL A 11.0 5.1 0.0 DL + 0.75*UBR + 0.75*WU. D 4.9 -6.0 0.0 DL + 0.75*LL + 0.75 A 4.9 3.2 0.0 OL + 0.75 + Q75 D 5.9 -4.0 0.0 DL + 0.75*% + 0.75 *WL2 A 117 5.8 0.0I DL + 0.75*% + 0.75'WL2 0 9.8 -6,7 0.0' DL + 0.75*UBL + 0.75*WL2 A 5.1 5.8 0.0 OL + 0.75*UBL + 035 *WL2 0 13.4 -6.7 0.0 DL + 0.75*UOR + 0.75*WL2 A 12.3 5.8 0.0 DL + 0.75*UBR + 0.75*WL2 D 6.2 -6.7 0.0 DL + 0.75 + 0.75*YAR A 4.6 3.3 0.0 OL + 0.75*11 + 0.75 *WLR 0 3.6 -Z5 0.0 OL + 0.75% + 0.75 *WLR A 8.5 6.0 0.0 DL + 0.75*% + 0.75 D 7.4 -5.1 0.0 DL + a75 + 0.75*WIR A 4.9 6.0 0.0 DL + 0.75*UBL + 035*BLR D 11.0 -5.1 0.0 OL + 0.75*U8R + 0J5*WLR A 12.1 6.0 0.0 OL + 0.75*UBR + 0.75*WLR 0 3.8 -5.1 0.0 OL + 0.75*LL + 0.75*02 A 5.9 4.0 0.0 DL + 0.75*LL + 0.75 D 4.9 -3.2 0.0 DL + 075*S. + 0.75 *WR2 A 9.8 6.7 0.0 OL + 0.75 + 0.75 *WR2 0 83 -5.8 0.0 OL + 0.75 + 0.75 *WR2 A 6.2 6.7 0.0 OL + 0.75*UBL + 0.75*WR2 0 12.3 -5.8 0.0 OL + O.75 + 0.75 *WR2 A 13.4 6.7 0.0 BL + 0.75*UBR + 0.75 *WR2 D 5.1 -5.8 0.0 Main Frame Reactions at Unes: 2 (FULL RAY) NOTE; A D AD reactions ore shown in Kips A negative value, indicates opposite direction Front Sw Rack SW t Hor + Hor + {`\ Mom + Mom + Condition Grid Yer Nor Mom DL A 3.2 2.0 0.0 DL 0 3.2 -210 0.0 DL + I A 18.7 12.6 0.0 DL + LL 0 18.7 -12.6 0.0 DL + SL A 30.0 20.3 0.0 OL + SL 0 30.0 -20.3 0.0 DL + UBL A 19.5 20.4 0.0 DL + IJBL 0 40.6 -20.4 0.0 DL + IIBR A 40.6 20.4 0.0 DL + UBR D 19.5 -20.4 0.0 0.6 *DL + WLL A -8.3 -5.5 0.0 0.6'01. + WLL 0 -5.2 2.9 0.0 0.6 + W12 A -4.5 -3.4 0.0 0.6'01. + WL2 D -1.4 0.8 0.0 0.6 + WLR A -5.2 -.2.9 0.0 0.6 + WLR D -8.3 5.5 0.0 0001. + WR2 A -1.4 -0.8 0.0 0.6'01. + WR2 0 -4.5 3.4 0.0 DL + 0.75 "LL + 0.7544. A 7.1 4.9 0.0 OL + 0.75 + 0.75 D 9.5 -6.8 0.0 DL + 0.75 + 0.75*WLL A 15.6 10.8 0.0 DL + 0.75 *SL + 0.75*WLL 0 18.0 -12.7 0.0 OL + 0.75 *USL + 0.75 A 7.7 10.8 0.0 BL + 0.75"U81. + 0.75 0 25.9 -12.7 0.0 DL + 0.75 "UBR + 0.75*YA.L A 23.6 10.8 0.0 OL + 0.75 + 0.754LL D 10.1 -12.7 0.0 OL + 0.75*Ll. + 0.75 *WL2 A 10.0 6.5 OA DL + 0.75*LL + 0,75 1.2 D 12.3 -8.4 0.0 OL + 0.75*SL + 0.75 A 1115 12.3 0.0 DL + 0.75 + 0.75*WL2 D 20.8 -14.2 0.0 OL + 0.75 + 0.75*WL2 A 10.6 12.3 0.0 OL + 0.75 *1181. + 0.75 %2 D 28.7 -14.2 0.0 DL + 0.75*UBR + 0.75*VA.2 A 26.4 12.3 0.0 DL + 0.75*UBR + 0.75*WL2 D 12.9 -141 9.0 DL + 0.75*LL + 0.75 *WLR A 9.5 6.8 0.0 DL + 0.75*U. + 0.75*WLR D 7.1 -4.9 0.0 DL + 0.75*SL + 0.75 A 18.0 12.7 010 DL + 0.75 *SL + 0.75 *ri1R 0 15.6 -10.8 0.0 DL + 0.75*08L + 0.7540 A 10.1 12.7 0.0 DL + 0.75*UBL + 0.75*KR D 23.6 -10.8 0.0 DL + 0.75*1.181? + 0.75*WLR A 25.9 12.7 0.0 DL + 0.75*UBR + 0.75 *WLR 0 7.7 -10.8 0.0 DL + 0.75 *LL + 0.75*WR2 A 12.1 8.4 0.0 DL + 0.75'11 + 0.75*WR2 0 10.0 -6.5 0.0 OL + 0.75 *SL + 0.75*WR2 A 20.8 14.2 0.0 DL + D.75'Sf. + 0,75*02 D 18.5 -12.3 0.0 DL + 035 "U81. + 0.75 *WR2 A 119 14.2 0.0 DL + 035 "UBL + 0.75 *WR2 0 26.4 -123 0.0 DL + 0.75*UBR + 0.75*WR2 A 23.7 14.2 0.0 OL + 0.75*UBR + 0.75*WR2 D 10.6 -12.3 D.0 Eat is metal • • 7301 F ZI P 7 oEscRIPTioN BASE PLATE DETAILS AND REACTION: SIZE SEE BUILDING DESCRIPTION SHEET C1 CUSTOMER TRI -STEEL CONSTRUCTION CO. INC. LOCADON REXBURG, ID. lIC Wilding Company AIRVfEW " HOUSTON, TEXAS • P.O. BOX 40338 41 (713) 466 - -7788 ZIP 77240 NONE I 3305 - 220165 SAME CAD BY LFC LD0 SHEET N0. ISSL A F2of2 0 ELEVATION @ LINE "A" � '2 " "0" M. BOLTS FRONT' SIDEWALL GIRT CONN, LONG CUP I /— TYP) i (I� x .019) -IG_ U�Si's{.2 N "2L _ U435'EI"'irN41 — _ G}ySfL�HI'{'IG Q 37oY� (TYP) I I W 240 TYf' 1I^I UT'I P�) 7' - S' -0 7' -6 7'6 5' -0 7' -6 f 3 1' -3 3' -0 20' -0 20' -0 _ U PL' UN EXT. PURtJ EXT. ELEVATION @ LINE "D 9' BACK SIDEWALL SCREW FOR INSULATED PANELS SPACED 0 42" O.C. MAXIMUM if SYMBOL I QTY, LOCATION DESCRIPTION O 6 COL. / RAF. 5/8" DIA. X 1 1/4" A3 5 BOLTS WITHOUT WASHERS 0 RAF. ; RAF. 5/8" DIA. X 1 3/4" A325 BOLTS WITHOUT WASHERS O.H. DOOR JAMB 2 12 C B D 1 A (rn I 7i�i(orofa►� I I TR T? - iJg -� � 4 X.019) ° - SC97 ° 111 011423N DRAWING S TATUS AEVXSOW FOR APPROVAL - NO. DAT DESCRIPTION THESE DRAWINGS, BEING FOR APPROVAL, ARE BY DEFINITION NOT 0 1/ - p4 FOR CONSTR FINAL, AND ARE FOR CONCEPTUAL REPRESENTATION ONLY. THEIR - - -- - - - -- PURPOSE IS TO CONFIRM PROPER INTERPRETATION OF THE PROJECT DOCUMENTS. ONLY DRAWINGS ISSUED "FOR CONSTRUCTION" CAN BE SIDEWALL FRAMING BOLTS CONSIDERED AS COMPLETE. QTY DESCRIPTION SIZE FOR PFRMIT. — THESE DRAWINGS, BEING FOR PERMIT, ARE BY DEFINITION NOT FINAL GIRT LAP BOLTS DIA. x 1 M8. IN THAT, AS A MINIMUM, PIECE MARKINGS ARE NOT IDENTIFIED. ONLY 4 GIRT TO FRAME k° DIA, x 1" M8. DRAWINGS ISSUED " FOR CONSTRUCTION " CAN BE CONSIDERED AS COMPLETE. X FOR CONSTRUCTION, FINAL DRAWINGS. ,TM metallic building company 7307 FAIRIAEW a HOUSTON, TEXAS * P.O. BOX 40336 ZIP 77041 (713) 466 -7788 ZIP 77240 DESCRIPTION SIDEWALL & ENDWALL FRA MING SIZE SEE BUILDING DESCRIPTION SHEET C1 CUSTOMER TRI —STEEL CONSTRUCTION CO. INC. SAME —� LOCATION REXBURG, ID. I CAD BY V C DRN. BY I CK D BY DATE SCALE JOB N0. PH 81.D SC. SHEET NO. ISSUE 'ZAV I z>Vj s- -I_ ¢..oyo NONE 3305 - 220165 A i E2 Of 4 0 ELEVATION @ LINE "119 LEFT ENDWALL TD (�') I -'* - "'-- �'L (y ! ^�{ T�rP) (I x .019) ° r ; --_- i �i2lny5 -to 1 ;` 0 I F'Ft BASE MNGLE R AT '240 i ELEVATION @ LINE "3 RIGHT ENDWALL 0 M m PORTAL FRAME DETAIL ENDWALL F RAMIN G BOLTS OESCRtPTiO SIZE qR7 t AP D OLTS �" D tA. _ .1" GIRT TO FRAME I ti" DIA. x 1" F. Ft R4 ' � Ii3ASt 2 I Lt , -RA1 - 0 I f I2S -8 MAIN FRAME MAIN FRAME (4) 1" x 1 A325\ " \ (8) °" $ 2• LIAP WBx10 A325 BOLTS x /'�" C's. BRKT. 01 RAFIER a 6" x It " FLNG's I l `12" x 10Q. WE Z \ \ COLUMN FLNG's i / 10" x Ift. WEB / ,TM metallic building company 7307 FAIRIAEW a HOUSTON, TEXAS * P.O. BOX 40336 ZIP 77041 (713) 466 -7788 ZIP 77240 DESCRIPTION SIDEWALL & ENDWALL FRA MING SIZE SEE BUILDING DESCRIPTION SHEET C1 CUSTOMER TRI —STEEL CONSTRUCTION CO. INC. SAME —� LOCATION REXBURG, ID. I CAD BY V C DRN. BY I CK D BY DATE SCALE JOB N0. PH 81.D SC. SHEET NO. ISSUE 'ZAV I z>Vj s- -I_ ¢..oyo NONE 3305 - 220165 A i E2 Of 4 0 ELEVATION @ LINE "119 LEFT ENDWALL TD (�') I -'* - "'-- �'L (y ! ^�{ T�rP) (I x .019) ° r ; --_- i �i2lny5 -to 1 ;` 0 I F'Ft BASE MNGLE R AT '240 i ELEVATION @ LINE "3 RIGHT ENDWALL 0 M m PORTAL FRAME DETAIL ENDWALL F RAMIN G BOLTS OESCRtPTiO SIZE qR7 t AP D OLTS �" D tA. _ .1" GIRT TO FRAME I ti" DIA. x 1" F. Ft R4 ' � Ii3ASt 2 I Lt , -RA1 - 0 I f I2S -8 MAIN FRAME MAIN FRAME MEMBER DATA Column data is lis ted fa Base to Eow - Rafter dote is list from E ave to Peak _ - 41or'x �Oe tside f 7 Web I I nside no 5/16 x 0 -10 10 CA x 15 5/16 x 0-10 1/4 x 6 3/16 x 30 to 18 1/4 x 6 1/4x6x20 -0 10CAx18x20 -0 1 /4x6x7..0 -0 OC PANEL 11�� , $4 A <8 1/2 x o-f0 x 2 -10 11/16 Plate N11h (12) 3/4 D'a. x 2 A325 1/2 x 6 x 2 -2 1/4 Plate With (8) 5/8 Dio. x 2 /325 DRAWING STATUS EM APPROVAI , R0. DATE THESE DRAWINGS, BEING FOR APPROVAL, ARE BY DEFINITION NOT 0 11..3 .0 FINAL, AND ARE FOR CONCEPTUAL REPRESENTATION ONLY. THEIR PURPOSE IS TO CONFIRM PROPER INTERPRETATION OF THE PROJECT DOCUMENTS. ONLY DRAWINGS ISSUED "FOR CONSTRUCTION" CAN BE CONSIDERED AS COMPLETE. Fj EOL PERMIT! THESE DRAWINGS, BEING FOR PERMIT, ARE BY DEFINITION NOT FINAL IN THAT, AS A MINIMUM, PIECE MARKINGS ARE NOT IDENTIFIED. ONLY DRAWINGS ISSUED " FOR CONSTRUCTION " CAN BE CONSIDERED AS COMPLETE. X EOB. r_�I.STRI.FCnnN� FINAL DRAWINGS. ASM800 DESCI8PTi0N BY CK'D metallic building company FOR CONSTRUCTION V 7301 FAIRV+EW • HOUSTON, TEXAS • P.O. BOX 40338 ZIP 77041 (713) 466 -7788 ZIP 77240 DESCRIPTION CROSS SECTI Sim SEE BUILDI DESCRI PTION SHEET C1 - wsTONER TRI -STEEL CONSTRUCTION CO. INC. SAME LOCATION REXBURG, ID. I CAD BY LFC RN. BY CK O BY ATE SCALE J06 PH BLDG O�Se. SREE N . ISSUE ZAy D� 11_,4 -d� NONE 3305 - 220165 A E3 of 4 0 L 31-0 _.1 60' -0' Out /Out of Sted CANOPY PRJ. Main Frame Cross Section at Frame Lines: t &3 (N.T.S) u7 <r ti N A307 Bolt w/o Washer Hot Roll or Built Up Connection Flanae Brac INS0006G y � _ 2 _� y__ 2 _ y 1 3/4 I I 11 3/4 3" Pu in / Girt Clip PL 3/16" x 6" R Lap Pattern "G" B N Rafter 2 Bolts Unless Noted on Erection Drawings ^? All Bolts are 1/2" x 1" A307 M. Bolts 2 Bolts Unless Noted on Erection Drawings 2' -4" Purlin -Girt Clip U o - - -- ----- -- - - - - -¢ ------ - --- - - - -- -- ZEE A \a � e ol e °c e�� Ql o° B " 2 „ 0 12" 4" O Se � ° o With Out Liner 2' - 4" r Purlin -Girt Clip G� ` \ QQ F Liner Clip uv a„ F ": -�1 Field Bend Cold Form Connection na Web Bolted o W ---- - -- -- ------- - -- - -- ¢_ -------- ---------- M Zee Clip d Field Bend 8" SC -22 F.46 �eR 1 < o°e o if req'd. /l F�on9e 2 , X � 49� 10" SC -77 / o \- 2 �� 12" SC -78 See `0oobor With Liner By —Pass Web Bolted Flange Brace Detail NS0006U 3 3/4 2 2 3/16" 3" Exa mple: Diameter Length Head Type Material Finish , Purlin / Girt -- Clip #12 -14 x 1 -1/4" Type 3 HWH, Self- Drilling,Carbon Steel, .0005 Minimum Zinc Plate PL 3/16" x 6" I Threads Tpoint Fastener Type All Bolts are 1/2" x 1" Per Inch A307 M. Bolts Lap Pattern "S" B Self- drilling fasteners are designed to drill the material and tap the hole. Material thickness is an important consideration when determining the proper point diameter. The point diameter is described as the point TYPE. Point types Are as follows: TYPE 1: Light gauge application TYPE 2: Medium light gauge application TYPE 3: Medium gauge application TYPE 4: Medium heavy gauge application TYPE 5: Heavy gauge application The point diameter allows the threads to tap into the material without excessive force which can break the shank, or very low force which con easily strip -out the material during seating torque. Each point type has a specific FLUTElength which allows the chip to escape from the hole during the drilling operation. Depending on the application, some drill screws require a special PILOTsection. The pilot section is the area that is unthreaded on the drill point. The pilot area is important to the performance of the fastener, The reason for the pilot area is so that the drilling of the hole is completed before the threads engage. If the threads engage before the drilling is completed, the drill point will have a tendency to burn because the threads will force the point into the material. Rake Angle Material Thickness: Drilling Point Capabilities .500 .312 .250 .110 .098 Point Type: Type 1 Type 2 Type 3 Type 4 Type 5 Light Duty Medium Duty Medium Duty Heavy Duty Heavy Duty #10 (.035 -.090) #6 (.035 -.098) #8 (.100 -.140) #12 (.145 -.312) #12 (.250 -.500) #12 (.035 -.090) #8 (.035 -.100) #10 (.110 -.175) 1/4" (.035-,090'#10 (.090-A10)1#12 (.090 -.210) Girt #18 (.035 -.098) #12 (.050- .140)1/4" (.110 -.250) Self —Dri Endwall Column (Shape Varies) (6) 5/8 x 1 1/4" A325 Bolts with (1) washer each Section Thru Rake at Main Frame Flush Endwall NSO013 The length of the tip required on a drilling fastener is determined by adding the thickness of the top material, any insulation or void between the top material and bottom material, and the thickness of the bottom material. If a hole larger than the screw thread has been pre - drilled or punched into the top material, only the thickness of the bottom material need be considered. (The threaded portion of the shank must be long enough to extend into and through the bottom material drilled.) Predrilled Hole Diameter Drilled or Punched Void or f Total Thickness to be ( Drilled Lap Detail By—Pass Purlin f Girt Lap Details Self Drilling Fastener Terminology Drilling Tip Length Determination NS0006S NS0007 NS0007B NOTE: 1. These drawings are intended to depict general installation of item(s) described above. Some item(s) may have been omitted for clarity of presentation. Consult your erection manual or additional S- Sheets for further guidelines and /or clarifications tiro.,, u \rne\c n.nw nn \n.nW;nn \NCn.nmfnne e"i N­;­ 1 A1 FFnvp Crrnt I- 1' -0" - I Width Minimum r Floor To Eave Strut Framed Opening Framing Details (Welded Clips — No Liner Steel Line Steel Line Eave Strut a- Girt ----------- �. Door Jamb Door Jamb Jamb To Girt Conn. Jamb To Eave Strut Conn. All connection bolts are 1/2" x 1" mach. bolts 1/4" 4, Ic N O N C c Jamb Jamb Girt oc Header a Header To Jamb Conn. Girt To Jamb Conn. olts Framed Opening with Welded Clips No Liner or Liner below the Header BOLT PER ENGR. ­ LR DISTANCE 1/2 X 1 VE CANOPY RAFTER EAVE BUTT CHANNEL BOLTON HEAD S UT S 1/2" X 1 M.F. RAFTER MACH. BOLTS (2) 5/8" x 1 1/2" A325 PROJECTION BOLTS UNLESS NOTED ON Y -PASS ERECTION DWG. EAVE CANOPY AT MAIN FRAME 4" 4" EAA STRI Y RAFTER SECTION "A EAVE CANOPY FRAMING DETAIL NS0017 NS0029 REVISIONS N0. DATE DESCRIPTION BY CK'D S t an da r d D e Q u � S 11 -04 -04 FOR CONSTRUCTION u � Customer: TRI- STEEL CONSTRUCTION CO. INC End User: SAME Location: REXBURG, ID Det. By I !!111_04 _04 Date Scale Building ID Jab Number Sheet Number Issue N.T.S. 3305 - 220165 NS -1 relate Column Width Minimum Floor To Zee Girt Head Threads Type Per Inch _ - 1 tn. Girt Girt Header c �I o� Girt Girt E 6 E � Fin. Flr. I- 1' -0" - I Width Minimum r Floor To Eave Strut Framed Opening Framing Details (Welded Clips — No Liner Steel Line Steel Line Eave Strut a- Girt ----------- �. Door Jamb Door Jamb Jamb To Girt Conn. Jamb To Eave Strut Conn. All connection bolts are 1/2" x 1" mach. bolts 1/4" 4, Ic N O N C c Jamb Jamb Girt oc Header a Header To Jamb Conn. Girt To Jamb Conn. olts Framed Opening with Welded Clips No Liner or Liner below the Header BOLT PER ENGR. ­ LR DISTANCE 1/2 X 1 VE CANOPY RAFTER EAVE BUTT CHANNEL BOLTON HEAD S UT S 1/2" X 1 M.F. RAFTER MACH. BOLTS (2) 5/8" x 1 1/2" A325 PROJECTION BOLTS UNLESS NOTED ON Y -PASS ERECTION DWG. EAVE CANOPY AT MAIN FRAME 4" 4" EAA STRI Y RAFTER SECTION "A EAVE CANOPY FRAMING DETAIL NS0017 NS0029 REVISIONS N0. DATE DESCRIPTION BY CK'D S t an da r d D e Q u � S 11 -04 -04 FOR CONSTRUCTION u � Customer: TRI- STEEL CONSTRUCTION CO. INC End User: SAME Location: REXBURG, ID Det. By I !!111_04 _04 Date Scale Building ID Jab Number Sheet Number Issue N.T.S. 3305 - 220165 NS -1 relate Column Width Minimum Floor To Zee Girt Head Threads Type Per Inch NOTE: No More Than (4) Purlin Peak PBR „g,. Eove Strut Straight Wind Bent Column and Inside Spaces Before Criss - Cross. Roof Member Screw Inside Closu - -- Rafter Preferred (Column may be 5 1 -- Panel Tapered) _ of 12' O.C. f - ----= �--- - - -- - -- Building Column Building Column C nstallation For More Than - - ----- L� Purlins '\- Strapping Peak Wind Bent I 6 Member ;� � (1 1/2" x .019) Cap "C' -� - Offset Panel Ca Trim Screw Main Frame - -- - - - - - - (BFL271 ) Column Strut Purlin Peak Section A' Bay Spacing C.L. Wind Bent ` t _ �' •., Frame I -- - -- - -- Eave Strut 1'. Fastener #14 Wind Bent Elevation f - ___- ______ 1/8' x 3/16' Pop Rivet Eave Strut Wall Panel C --- -�- -- -� -� At 10 - 0' O.C. E O O Installation For (6) or Less Purlins E O O Eave Canopy Detail w/o Soffit Panels g Roof Uplift Strap Installation �+ (a) {Refer fo Roof Plan for Locations) 5/8" x 1 1/2" Wind Bent A325 Bolts roc e NOTE. 1) Attach Straps w Member Screws ( w/o Washer at Purlins or Girls. PBR Member Screw 5/8" x 1 1/2" 2) Do Not Criss -Cross Straps in Walls. ROOF At 12" O.C. A325 Bolts ct Panel Section " B " `Rake Angle Eave Strut Member Bracket Outside Closure Screw SC -169 A -325 Bolts !, 1 (Tm ) Soffit Panel 6 1/2" b Main Frame Anchor Main Frame Column Bolts Column Strapping (Typ.) Eave Strut Girt Girt ✓ (1 1 /2" x .019) Bevel Cap Trim Girt (BFL142) Fastener #4 Lop Low Girt Wall Panel # 14 x 7/8" L p Tek wind Bent formed Base Trim J at 12" O.C, / Formed Base Trim Formed Base Trim Column f (M ay Vary) (M ay Vary) (May Vary) Eave Canopy Detail w /Soffit Panels -X � Endwall Law Girt Sidewall 6 1/2" -X( Bo y Boy Steel Line Wall Suction Strap Installation Wind Bent at Main Frame Section " C " (Refer to Wall Elevation For Location) Eave Canopy Trim Sections Section "A" PBR Roof - 1 1 /4' Wall Panels Flush Wind Bent �ESee Anch Bolt P lan Roof Uplift and Wall Suction Strap Details (for Peak Buildings) NS0030A NS0052A NS0058 PROJECTION +3" W SOFFIT V - 3 1/4 PROJECTION W10 SOFFIT Strut Spacer Strut Purlin Ridge Tie Bldg. Ridge PURLIN (Beyond) ----1• (SYMM.) �EACH �_ o a 1 RAKE `MAIN FRAME RAFTER 8" Purlin RAKE ANGLE ANGLE 12" Purlin 5/8" X 1 1/4 RT -08 A RT -10 A RT -12 A A325 BOLTS RT -08 B RT -10 B o FLANGE BRACE RT -08 C RT -10 C RT -12 C (IF REO'D) RT -08 D RT -10 D ENDWALL 4 RT -08 E ENDWALL COLUMN .911 16 GIRT 7.759 1.081 1. FLUSH GIRT ENDWALL W/ PURLIN EXTENSION 2'a 2�e PROJECTION +3" W /SOFFIT V -11 1/4 0.976 9.177 1/44 PROJECTION W/O SOFFIT 2.137 8 Z 13 8 2's PURLIN .956 3/1 Hillside Washer - SCREW AT EACH MEMBER r ° ° o 1.577 2.724 Flat Washer - Eave Strut) Knock-in -/ Bridging (KBA -XXXX) At Strut Purlin Fastener #1B Eave 1/4 " -14 x 1 -1/4" Driller Strut w/o Washer (­` Purlin LL1 "xI "x14 Go. Cable Brace (KBB -XXXX) Low Side Eave Strut ut Knock -In Bridging - L 1" x 1" x 14 Go. (KBA -XXXX) (KBB -XXXX) High Side Eave Strut 1 - \- MAIN FRAME RAKE RAKE RAFTER Hex Nut Eye Bolt ANGLE ANGLE 5/8" X 1 1/4 Step 1 Step 2 KiEL A325 BOLTS Web of Frame Insert Tab Bend Tab DIMENSIONS WILL VARY WHEN USED o FLANGE BRACE Into Slot IN CONJUNCTION W /AN EAVE CANOPY EN WALL (IF REO'D) P Back U Plate 90 Degrees CO MN Note ENDWALL I ` GIRT Bend Line B 1/4 1' - RgkL The bridging must be inserted into the pre - punched slot in the Purlin, as shown, and the tab bent side ways for BY -PASS GIRT ENDWALL W/ PURLIN EXTENSION proper Installation. The process must be complete for Cable Brace to Frame Connection the bridging to function as designed. NOTE: ALL CONN. BOLTS ARE 1/2" x 1" MACH. BOLTS UNLESS NOTED Note: Shop welded Back Up Plate may be located Knock -In Bridg Installation MAIN FRAME (If Requied By Design) PURLIN EXTENSION FRAMING DETAILS ENDWALL side web. 9 g ( � (For Roof Slopes Below 3:12) NS0033 NS0053 NS0059 NOTE: 1. These drawings are intended to depict general installation of item(s) described above. Some item(s) may have been omitted for clarity of presentation. Consult your erection manual or additional S- Sheets for further guidelines and /or clarifications. i:1..,..... u. \/�,.a \c n......:.,,..\ h ......:.,..,. \nicn.,....:..,... a..i ht..._:_., n t\ N Roof 12 I 12 R Slope r - / -- I Si( / (3) Fos ner #1B \ ,� �° /4 " - 14 xl 1 1/4" Driller Ridge Tie Line WP Ridge Tie Pre -Set to W. P. Line Up with Bottom Ridge Tie of Purlins Roof slope 8" Purlin 10" Purlin 12" Purlin 1/2 RT -08 A RT -10 A RT -12 A 1 RT -08 B RT -10 B RT -12 B 2 RT -08 C RT -10 C RT -12 C 3 RT -08 D RT -10 D RT -12 D 4 RT -08 E RT -10 E RT -12 E Ridge Tie Installation IF-- w Ridge Tie Knock - In Bridging (Typ.) (Typ.) (LI" x 1" x 14Ga.) E0 E ° See: 1 2 KBA -XXXX E NS59, NS59A See Erection Dwgs & NS598 For marks 0 See: NS59 Or Low Love Lave Strut Eave 5-0" 5' -0" 10' -0" 7' -6" 5-0" 7'- 20'-0" 20' -0" End Bay Interior Bay Knock -In- Bridging Layout Double Slope Roof - 20' Bays Standina Seam Roof NS0059C REVISIONS N0. I DATE DESCRIPTION 11 -04-041 FOR CONSTRUCTION Notice: A minimum of 1/4" space should be allowed from the sheet end to any surface. Remove insulation from vinyl backing. U Insuation must not u Fold be exposed to o n 1 1j4" weather. o Max. Steel Line Member Screw 12 -14 x 1 1/4" Wall Panel at 12" O.C. Anchor Not by BIdg,Mfg. 1/4" Dia. Anchor (min.) at 60" 0. C. (min.) not by Bldg Mfr. Base Angle Notice: Base Trim If insulation is req'd install trim first. BFL161 Base Angle Section w/o Panel Recess w/ Base Trim NS0062E Cold Formed Steel Components Yield Strength = 57.0 K.S.I. (Typ.) 8 Dimensions nT P_ 16 0.82 ?. Member Pro ernes 1.668 shape y Bt �' L D X D B1 82 Li Ga. Area Ix I Sx off 8 Z 16 8 2'a 2�a See: NS59 Or Low Love Lave Strut Eave 5-0" 5' -0" 10' -0" 7' -6" 5-0" 7'- 20'-0" 20' -0" End Bay Interior Bay Knock -In- Bridging Layout Double Slope Roof - 20' Bays Standina Seam Roof NS0059C REVISIONS N0. I DATE DESCRIPTION 11 -04-041 FOR CONSTRUCTION Notice: A minimum of 1/4" space should be allowed from the sheet end to any surface. Remove insulation from vinyl backing. U Insuation must not u Fold be exposed to o n 1 1j4" weather. o Max. Steel Line Member Screw 12 -14 x 1 1/4" Wall Panel at 12" O.C. Anchor Not by BIdg,Mfg. 1/4" Dia. Anchor (min.) at 60" 0. C. (min.) not by Bldg Mfr. Base Angle Notice: Base Trim If insulation is req'd install trim first. BFL161 Base Angle Section w/o Panel Recess w/ Base Trim NS0062E Cold Formed Steel Components Yield Strength = 57.0 K.S.I. (Typ.) 8 Dimensions 2 .773 16 0.82 ?. Member Pro ernes 1.668 shape y Bt �' L D X D B1 82 Li Ga. Area Ix I Sx off 8 Z 16 8 2'a 2�a .911 16 0.822 7.759 1.081 1. 8 Z 14 8 2'a 2�e .930 14 0.976 9.177 1.289 2.137 8 Z 13 8 2's 2�s .956 13 1.185 11.095 1.577 2.724 8 Z 12 8 2' 2 .990 12 1.463 13.624 1.967 3.347 10 x 2 Z 14 10 2 2aa .930 14 1.116 15.642 1.290 2.858 10 x 2 Z 13 10 2 2 J .956 13 1.355 18.933 1.578 3.727 10 x2 Z 12 10 2 2�a .990 12 1.673 23.285 1.968 4.586 N 10 3 3sa .930 1 -1.256 19.094 3.077 2.907 10 x 13 10 3 3�a .956 13 1.525 23.112 3.759 3.933 10 x 3 Z 12 10 3 t; 3 .990 12 1.883 28.427 4.681 4.932 12 Z 14 12 3'a 3�a .930 14 1.396 29.321 3.078 3.470 12 Z 13 12 3'a 3� .956 13 1.69 35.515 3.760 4.733 12 Z 12 12 3 3�a .990 12 2.093 43.722 4.682 6.374 d v r d W NS0067 Sta n dun r Customer: TRI- STEEL CONSTRUCTION CO. INC End User: SAME Location: REXBURG, ID Det. By Chk By Dote I Scale . Building ID I Job Number I Sheet Number Issue 11 -0a -04 I N.T S 3305 - 220165 NS -2 Peak' Purlins L 1" x 1" x 14go (KBA -XXXX) Typical Unless Noted At Ridge Section Nam 8 Dimensions 2 .773 16 0.82 ?. Member Pro ernes 1.668 shape y Bt �' L D X D B1 82 Li Ga. Area Ix I Sx off 8 Z 16 8 2'a 2�a .911 16 0.822 7.759 1.081 1. 8 Z 14 8 2'a 2�e .930 14 0.976 9.177 1.289 2.137 8 Z 13 8 2's 2�s .956 13 1.185 11.095 1.577 2.724 8 Z 12 8 2' 2 .990 12 1.463 13.624 1.967 3.347 10 x 2 Z 14 10 2 2aa .930 14 1.116 15.642 1.290 2.858 10 x 2 Z 13 10 2 2 J .956 13 1.355 18.933 1.578 3.727 10 x2 Z 12 10 2 2�a .990 12 1.673 23.285 1.968 4.586 10 x 3 Z 14 _3Z 10 3 3sa .930 1 -1.256 19.094 3.077 2.907 10 x 13 10 3 3�a .956 13 1.525 23.112 3.759 3.933 10 x 3 Z 12 10 3 t; 3 .990 12 1.883 28.427 4.681 4.932 12 Z 14 12 3'a 3�a .930 14 1.396 29.321 3.078 3.470 12 Z 13 12 3'a 3� .956 13 1.69 35.515 3.760 4.733 12 Z 12 12 3 3�a .990 12 2.093 43.722 4.682 6.374 8 x 2 C 16 8 2 2 .773 16 0.82 ?. 7.791 0.675 1.668 Y 8 x 2 C 14 8 2 2 .800 14 0.97(1 9.210 0.800 2.049 Y Bt 8 x 2'2 C 12 8 2'2 2'2 .885 12 1.463 13.649 1.196 3.412 10 E.S. 14 � 8 x 3 C 16 8 32 __ 312 .773 16 0.940 9.652 1.523 1.712 8 3'z C 14 8 1.200 3 .800 14 1.116 11.411 1.808 2.251 D l t 8 x 3 C 12 8 3's 1 .885 12 1.673 16.921 2.712 3.574 �L 10 x 3'z C 12 10 s 31 .885 12 1.883 28.456 2.912 4.861 12 x 3 C 12 12 3 3 .885 12 2.093 43.758 3.071 6.293 82 8 E.S. 16 g 3� 5 1,088 16 1.058 10.936 2.902 1.890 8 E.S. 14 8 3 5 1.114 14 1.256 12.924 3.440 2.499 Y 8 E.S. 12 8 3 5 1.200 12 1.883 19.143 5.142 4.001 �L 10 E.S. 14 10 3 5 1.114 14 1.396 21.670 3.697 3.161 10 E. 2 10 3' 5 1.200 12 2.093 32.195 5.537 5.458 p X 12 E.S. 14 12 3 5 1,114 14 1.536 33.201 3.907 3.815 12 E.S. 12 12 3 5 1.200 12 2.303 49.422 5.855 7.067 �L CEES PROFILE GAGE LEFT RIGHT COUNTER DEPTH FLANGE PROFILE GAGE LEFT RIGHT COUNTER 8 3 C 4 G_ G - 1 Depth Code Profile Code Left / Right End Punch 8 = 8" C = Cee NP = No Holes 10 = 10" Gage Code G = Simple 12 = 12" 2 = 12 go. S = Multi Holes Flange Code 3 = 13 ga. Counter 3 = 3 1/2" 4 = 14 ga. A numerical part 3 = 3 1/2" 6 = 16 ga. number from 1 to 999 ZEES G = Simple DEPTH FLANGE PROFILE GAGE LEFT RIGHT COUNTER 8 3 Z 4 G G - 1 2" a e Code Counter 8 = 8" 2 = 12 ga. A numerical part 10 = 10" 3 = 13 ga. number from 1 to 999 12 =12" 4 =14 go. 6 1/8" SC -57 6 =16 ga. Flange Code 2 = 2 1/2" Left / Right End Punch 3 = 3 1/2" NP = No Holes (once) G = Simple Profile Code S = Multi Holes Z = Zee L = Long X = Extra Long U = Super Lap Y = Simple Span EAVE STRUTS DEPTH FLANGE PROFILE GAGE LEFT RIGHT COUNTER SLOPE 8 3 EL 4 H H - 1 A Depth Code Gage Code Counter 8 = 8" 2 = 12 go. A numerical part 10 = 10" 4 = 14 ga. number from 1 to 999 12 =12" 6 =16 ga. Flange Code Left / Right End Punch Slope Code A = 1/2:12 3 = 3 3/8" NP = No Holes (once) B = 1:12 5 = 4 1/2" or 5" H = Simple C = 2:12 Profile Code M = Old Multi Holes D = 3:12 EL = Eave Low d = New Multi Holes E = 4 : 12 EH = Eave High NS0067A RIDGE FLASH FIXED EXPANSION RIDGE ROLL (13FL212) (BFL156) (18) STITCH SCREWS (16) STITCH SCREWS (2) BEADS TUBE (2) BEADS TUBE SEAL (36 ") SEAL (60 ") NOTE: 2" MIN. LAP NOTE: 2" MIN. LAP FASCIA CAP TRIM (BFL90) (5) STITCH SCREWS (5) POP RIVETS (2) BEADS TUBE SEAL (28 ") NOTE: 2" MIN. LAP FASCIA SILL TRIM (BFL92 -122) (4) POP RIVETS (2) BEADS TUBE SEAL (10 ") NOTE: 2" MIN. LAP Main Frame Wall Panel Thickness, Plus A" Column Rake Trim Projection, No Plus 1 /16" Tube Sealant Fold insulation back onto itself for 1/8 Pop Rivet Expansion Ridge Roll 8 -- compression between Eave Strut and roof panel, it must not be exposed outside Closure to the weather. Expansion At Ridge Ridge Cap a I O Ultra - Dek Roof Panel -rr— MEMBER FASTENER — D I ® 12" O.C. 0 ---- --- --- -------- ---- ---- Fastener #IE - - - - -- EAVE MEMBER ----------- -- - Peak Box - .....:::..::: (8C2 1/2 CHANNEL) Rake Support Parapet Rake Cleat BFL290 -8 ;Q Angle (Locate Directly In Front l S Insuation FASTENER # 12A 8" Girt „ Of Roof Panel And Against Rake (by others Support Angle W/ (3) Fasteners #1E It Stitch Screw # 2 PHILLIPS # 12x1' CANOPY EAVE : 0- - O j Wall Panel I II Fastener p5 TRIM BFL96- -- — Double Sided Tape (by Others) outside Closure ; - - ll (to be used to secure insulation.) Rake Angle PBR','PBA" Sldewall Wall Panel B" Rake Trim Proj. + 1/16" --- 1 4" Section ARTISAN PANEL 1' -3" 4" FASTENER # 1 POP Angle x x 1 a 1/8 "x3/16" POP RIVET 9 L 4" 2" 6 9 ( g ) ® 12" O.C. Required From Floor To Eave Strut t For Midwest Rake Trim (Dim. "A" = 4 7/8 ") Eave Strut For Midwest Rake Trim (Dim. "B" = 3 5/8 ") O = 1/2" x 1" A307 Bolt For Metallic Rake Trim (Dim. "A" = 3 11/16") For Metallic Rake Trim (Dim. "B" = 2 7/16 • = Open Hole Blanket Insulation Detail at Eave NS0094B ( 2 ) 1�2'Ox1" N303 M Bolts Purlin A Purlin 1 3p C 1ploteP Rafter P CI'ip 3 16' plate of Rafter Purlin Clip 3/16" Plate C Anti -Roll Clip • 3/16" Plate Main Frame Rafter Section A Purlin Anti —Roll Clip 3/ 16 3 3/16 3 Ultra —Dek /Double —Lok Expansion Ridge End Cap NS0105B Support Member Fastener #6A 12 -24 x 1 1/4" Tek 4.5 At 24" O.C. Fastener #12A 12 x 1" Pancake Driller, At 12" O.C. Panel Splice Trim -' BFL572 1 1 1 /4" 1 1/4" Fastener # 14 1/8 "0 x 3/16" Pop Rivets at 12" O.C. Note: Artisan Panel 20' -0 Maximum Length RIDGE PARAPET & FASCIA TRIM LAPS (at Built -up /Hot - Rolled Rafter Artisan Panel Soffit End NS0082 NS0099 NS0115 NOTE: 1. These drawings are intended to depict general installation of item(s) described above. Some item(s) may have been omitted for clarity of presentation. Consult your erection manual or additional S— Sheets for further guidelines and /or clarifications. SAVE OVERHANG SOFFIT SECTION (ARTISAN PANEL) (FOR 8C2 1/2 EAVE CHANNEL) NS0116 Wall Panel Sheeting Angle (SA2- ) Member Fastener 12 -14 x 1 1/4" At 12" O.C. Fastener #12A 12 -14 x 1' Pancake Head Self Driller _ Artisan Panel Panel Cap 8FL571 Fastener # 14 1/8 x 3/16" Pop Rivet at 12" O.C. Corner Detail at Main Frame Endwall 8" Flush Sidewall and 8" Endwall Columns shown (is hot rolled for demonstration only. They may be Built Up or Cold Form also. Outside I 2 BOLT FLUSH GIRT CONNECTION Closure NOTE: USE 1/2" DIA, X 1" A307 BOLTS AS SHOWN , i. Artisan Panel Soffit Section At Wall NS0117 REVISIONS DATE DESCRIPTION 11 -04 -04 1 FOR CONSTRUCTION Column Flange A 8 2 Bolt Clip 2 Bolt Clip up to 8" 2" 4 1/8" SC -3 SC -16 up to 10" 3" 5 1/8" SC -56 SC -72 up to 12" 4" 6 1/8" SC -57 SC -73 4 BOLT FLUSH GIRT CONNECTION NOTE: USE 1/2" DIA. X 1" A307 BOLTS AS SHOWN SIDEWALL or ENDWALL INTERIOR FLUSH GIRT CONNECTION DETAIL NS0125 Stainft Customer: TRI— STEEL CONSTRUCTION CO. INC End User: SAME Location: REXBURG, ID Det. By Chk By Date Scale Building ID Job Number Sheet Number I Issue 11 -04 -0a N.T.S. 3305 - 220165 NS -3 3rary: n: \uoo \� urawings \urawings \rvzurowmgs.axi iversion y.�t NS0124 , 7 r,,, Note: Refer to Technical Installation Manuals for the installation of the roof panels at the ridge. Expansion Ridge Flashing BFL156 a a Fastener # a 1/4 " -14 x 7/8" e Lap Tek At 6" O.C. Min. a Outside Panel Closure rM (required if ribbed panel) Soffit Ponel * Soffit Panel e a Soffit Peak Trim Fastener #4 1/4 -14 x 7/8" a a BFL84 3" Lop Tek p h* 3" at 12" O.C. ¢ � 0 (typical) C /os�re 9 ck hyy Up p �Ofe ¢0 Roof Panel Soffit Peak Trim Detail UltraDek / DoubleLok Roof Expansion Ridge Detail NS0 NS0759 Fastener #14 Note: Refer to Technical Installation Manuals for at 10' -0" O.C. Eave Plate the installation of the roof panels at the ridge. Ultra -Dek Or NW -7610 Double -Lok Roof BFL156 Fastener # 1/4 " -14 x 7/8" LL Lop Tek At 6" O.C. Tri -Bead Tape Sealant L 4 x 2 x 16 Ga. ------- --- --- HW -504 cc) I RAt -240 - -- _ Outside Metal Closure Fastener # ® HW -430 1/4 " -14 x 1" „`j, Back Up Plate Driller at 12" O.C. HW -7740 Eave Cover Trim Fastener #1 Tri -Bead Tape Sealant 8" BFL106O 1/4 " -14 x 1" HW -504 10" BFL1063 Driller at 12" O.C. Fastener #1E 12" BFL1066 1/4"-14 x 1 1/4" LL Eave Channel (9) per Panel 7" Expansion Ridge Flashing 2 CEISYm, BFL156 Roof Panel = - -- -- - -- -- -- -- Artisan Soffit Fastener #12A 12 x 1" Pancake Head Peak Purlin Fastener #4 1/4 -14 x 7/8 Long Life Lap Tek 1' -4" Blanket Insulation Eave Canopy Low Eave Fixed Eave - High System - Artisan Soffit UltraDek f DoubleLok Roof Expansion Ridge Detail NS0529 INS0759A NOTE: REVISIONS N0. DATE DESCRIPTION BY CK'0 I. These drowings are intended to depict general installation of item s) described above. Some item(s) may have been omitted for clarity of presentation. Consult your erection manual or additional S- Sheets for further guidelines and /or clarifications. Q Sfandar I 11 -04 -04 FOR CONSTRUCTION u T a i s Customer. TRI- STEEL CONSTRUCTION CO. INC End User: SAME Location: REXBURG, ID Det. By Chk By Date Scale Building ID Job Number Sheet Number Issue 11 -04 -04 N.T.S. 3305 - 220165 NS -4