Loading...
HomeMy WebLinkAboutSITE & BLDG PLANS - 06-00487 - Pinnacle Security - Storage Shedsu EXISTIN NOTE: LEGAL DOCUMENTS PROVIDE AN EASEMENT FROM KEY BANK TO ALLOW ACCESS TO PINNACLE PARKING LOT. WIDTH OF EASEMENT IS NOT INDICATED IN THE LEGALS BUT IS BEING NEGOTIATED. MIN. EASEMENT WIDTH BEING NEGOTIATED IS 24 FEET TO ALLOW TWO WAY TRAFFIC. AS THERE IS PARKING REPLACE SIDEWALK AND CURBING ON WEST SIDE OF BUILDING TO MEET CITY OF REXBURG STANDARDS. PROVIDE LANDSCAPING BETWEEN EXISTING CURB AND SIDEWALK. (1) SPACES RESERVED FOR KEY BANK v ul VJ u a w >z Q 4 z W O EXISTING! KEYBANk KIOSK I 20 PARKING SPOT RENTED TO PINNACLE BY KE Y BANK o A ,r �tAli EXISTING ASPHALT PARKING LOT - DR, RESPONSIBILITY OF KEY BANK O :FZ I _ I � I m I �I Ull O QI al I I 9 IN FLOOR AREA - 18589 SF ".OND FLI OTAL BUILT AREA OF PARKING TO PROPERTY LINE APPROX, 5240 SF. - SNOW STORAGE AT 10% - 924 SF - 1080 SF PROVIDED. HAIN LINK F KEY BANK PARCEL 115 24' N 5 89 0 44'59" W 164.284' RESIDENTIAL PARCEL LEGAL DESCRIPTION COMMENCING AT THE NW CORNER OF LOT 3, BLOCK 31, OF THE ORIGINAL REXBURG TOWNSITE, MADISON COUNTY IDAHO: THENCE N Be 44 5S E FOR A DISTANCE OF 191.50 FEET TO THE TRUE POINT OF BEGINNING; THENCE N Be 44 5S E FOR A DISTANCE OF 138.51 FEET: THENCE S 0 14 51 E FOR A DISTANCE OF 165.00 FEET; THENCE S 8S 44 59 W FOR A DISTANCE OF 165.02 FEET; THENCE S O 14 4S E FOR A DISTANCE OF 82.50 FEET; THENCE S 5S 44 59 W FOR A DISTANCE OF 165,00 FEET; THENCE N O 14 49 W FOR A DISTANCE OF 165,00 FEET; THENCE N Be 44 59 E FOR A DISTANCE OF 191,50 FEET; THENCE N 0 14 4S W FOR A DISTANCE OF 82.50 FEET TO THE TRUE POINT OF BEGINNING CONTAINING 1.5 ACRES MORE OR LESS. SHED I I , (10) SPA EP tu I I N � �eLn .e K LOT I I R NEW I �,- FRENdH RAIN I I 1 pD y;�� I I I I P E� N S PAC ES SNOW TOR CAE EXISTING" FRENCH DRAIN w 0 J N o rPA .r wit �11 � r_ 1% - 1 w 0 w w 0 J w 0 N 3' PINNACLE PARCEL (EXISTING PARKING LOT TO BE RESURFACED) (o REVISED 09/O"1/06 0 0 (V �n z N w > � lu Q ( Q ZONE - CBC 1 SETBACKS - FRONT = 20 FT SIDES = O FT " LOT COVERAGE = 50% III - 20 Z N � Q O m O ONLY AND IS NOT TO BE MAXIMUM BUILDING HEIGHT = 45 FT, r WITHOUT THE WRITTEN CONSENT cq BUILDING � � 1-1 Lu 2 STORIES = 24000 SF OF WHICH 10200 IS BEING REMODELED O U 0 CONSTRUCTION - TYPE V -B ' X Q LL NO FIRE SPRINKLER SYSTEM d � FRONT - 20 FT SIDES OFT MIN • - o REAR - O FT PARKING: �u0 STREET ROW: 20 FT Q ADJOINING PROPERTY LINE: O FT FRONT OF BLDG: 5 FT Z Z Q O- a z TOTAL AREA : 1.51 ACRES = 65816 SF ff j =3 ASPHALT m 4 BUILDING = 65816 SF U! LANDSCAPING = EXISTING CITY UTILITIES ARE EXISTING. z / PARKING =3 m 3 PER 1000 SF : 31 PARKING SPACES REQUIRED FOR AREA w BEING REMODELED AND USED AS BUSINESS SPACE. w- TOTAL POSSIBLE BUSINESS SPACE IS 12000 SF REQUIRING LL 15 PARKING SPACES. Q PARKING PROVIDED -w m (84) S' x 18' PARKING SPACES PROVIDED. ADDITIONAL OW STORAG REMODELS OCCUR, 5 89 0 44'59" W 164.284' RESIDENTIAL PARCEL LEGAL DESCRIPTION COMMENCING AT THE NW CORNER OF LOT 3, BLOCK 31, OF THE ORIGINAL REXBURG TOWNSITE, MADISON COUNTY IDAHO: THENCE N Be 44 5S E FOR A DISTANCE OF 191.50 FEET TO THE TRUE POINT OF BEGINNING; THENCE N Be 44 5S E FOR A DISTANCE OF 138.51 FEET: THENCE S 0 14 51 E FOR A DISTANCE OF 165.00 FEET; THENCE S 8S 44 59 W FOR A DISTANCE OF 165.02 FEET; THENCE S O 14 4S E FOR A DISTANCE OF 82.50 FEET; THENCE S 5S 44 59 W FOR A DISTANCE OF 165,00 FEET; THENCE N O 14 49 W FOR A DISTANCE OF 165,00 FEET; THENCE N Be 44 59 E FOR A DISTANCE OF 191,50 FEET; THENCE N 0 14 4S W FOR A DISTANCE OF 82.50 FEET TO THE TRUE POINT OF BEGINNING CONTAINING 1.5 ACRES MORE OR LESS. SHED I I , (10) SPA EP tu I I N � �eLn .e K LOT I I R NEW I �,- FRENdH RAIN I I 1 pD y;�� I I I I P E� N S PAC ES SNOW TOR CAE EXISTING" FRENCH DRAIN w 0 J N o rPA .r wit �11 � r_ 1% - 1 w 0 w w 0 J w 0 N 3' PINNACLE PARCEL (EXISTING PARKING LOT TO BE RESURFACED) (o REVISED 09/O"1/06 0 0 (V �n z N w > � lu Q ( Q ZONE - CBC 1 SETBACKS - FRONT = 20 FT SIDES = O FT " LOT COVERAGE = 50% III - 20 Z N � Q O m O ONLY AND IS NOT TO BE MAXIMUM BUILDING HEIGHT = 45 FT, r WITHOUT THE WRITTEN CONSENT cq BUILDING � � 1-1 Lu 2 STORIES = 24000 SF OF WHICH 10200 IS BEING REMODELED O U 0 CONSTRUCTION - TYPE V -B ' X Q LL NO FIRE SPRINKLER SYSTEM 4. SETBACKS REQUIRED: FRONT - 20 FT SIDES OFT MIN Lu - REAR - O FT PARKING: z to STREET ROW: 20 FT ADJOINING PROPERTY LINE: O FT FRONT OF BLDG: 5 FT Z Z Q O- TOTAL AREA : 1.51 ACRES = 65816 SF ff j =3 ASPHALT m 4 BUILDING = 65816 SF U! LANDSCAPING = EXISTING CITY UTILITIES ARE EXISTING. tl� PARKING =3 m 3 PER 1000 SF : 31 PARKING SPACES REQUIRED FOR AREA w BEING REMODELED AND USED AS BUSINESS SPACE. w- TOTAL POSSIBLE BUSINESS SPACE IS 12000 SF REQUIRING LL 15 PARKING SPACES. Q PARKING PROVIDED U (84) S' x 18' PARKING SPACES PROVIDED. ADDITIONAL FUTURE SPACES WILL BE PROVIDED AS FUTURE BUILDING REMODELS OCCUR, SITE PLAN FOR PINNACLE SECU ITY CONTACTOR'S RESPONSIBILITY IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL ASPECTS OF THESE DRAWINGS, ARCHITECTURAL AND STRUCTURAL, PRIOR TO CONSTRUCTION. ANY CONFLICTS SHALL BE REPORTED TO THE ENGINEER FOR CORRECTION, CHANGES MAY BE PROPOSED BY THE CONTRACTOR IF HE FEELS THE CHANGE IS IN THE BEST INTEREST OF THE OWNER. CHANGES SHALL BE FORWARDED TO THE ENGINEER IN WRITING FOR APPROVAL PRIOR TO CONSTRUCTION, ADDRESS: 51 SOUTH 16T EAST W U d Z THIS DRAWING IS FOR THIS LOCATION AND CUSTOMER ONLY AND IS NOT TO BE _ REUSED IN ANY MANNER WITHOUT THE WRITTEN CONSENT OF DESIGN INTELLIGENCE.LLC. � o z �o t fREx5ufR rz, .4 up c t ) cirl m A[) C(OUNT A I N Y lt: 'SHO z, m 3 0 as A U o0 z _ oa PROJECT DATA DESIGN NOTES I— w �m 1. GOVERNING BUILDINCa CODE: 2003 IRG GROUND SNOW LOAD - 4"1 PSF Q o � FLAT ROOF SNOW LOAD - 36 PSF 2. OCCUPANCY AND CROUP: U SNOW LOAD IMPORTANCE FACTOR - 1,0 SNOW EXPOSURE FACTOR - 0.9 3, TY OF CONSTRUCTION: TY V - 1:3 THERMAL FACTOR - 1.0 4, LOCATION ON PROPERTY: WIND - 90 MPH (3 SEC GUST) EXP 5 EXTERIOR WALLS: NON -RATED WIND IMPORTANCE FACTOR - 1.0 WIND EXPOSURE - 5 (SOUTHWEST) .— EXTERIOR OPENINGS: NON -RATED WIND INTERIOR PRESSURE COEF - 0.31 5, OCCUPANCY SEPARATION : NOT REQUIRED SEISMIC USE GROUP - GROUP I SEISMIC CATEGORY - CLASSIFICATION D1 SPRINKLED: NO FLOOR LIVE LOAD - 40 PSF z NUM5ER OF STORIES: 1.0 Q FLOOR DEAD LOAD - 15 PSF >= (o, FIRE RESISTIVE REQUIREMENTS: uj I-- z ROOF DEAD LOAD - 15 PSF � p SEE ARCHITECTURAL DWGS o z O 443� � 1/ uj I CONTACTOR'S RESPONSIBILITY " THIS DRAWING IS FOR THIS LOCATION AND CUSTOMER IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL ASPECTS OF THESE DRAWINGS, M "" " ONLY AND IS NOT TO BE ARCHITECTURAL AND STRUCTURAL, PRIOR TO CONSTRUCTION, ANY CONFLICTS SHALL BE REPORTED TO THE ENGINEER FOR CORRECTION. CHANGES MAY BE PROPOSED BY THE REUSED WITHOUT T ANY MANNER THE WRITTEN CONSENT CONTRACTOR IF HE FEELS THE CHANGE IS IN THE BEST INTEREST OF THE OWNER, CHANGES OF DESIGN INTELLIGENGE.LLC. SHALL BE FORWARDED TO THE ENGINEER IN WRITING FOR APPROVAL PRIOR TO CONSTRUCTION. I 7r 41 � o z �o t fREx5ufR rz, .4 up c t ) cirl m A[) C(OUNT A I N Y lt: 'SHO z, m 3 0 as A U o0 z _ oa PROJECT DATA DESIGN NOTES I— w �m 1. GOVERNING BUILDINCa CODE: 2003 IRG GROUND SNOW LOAD - 4"1 PSF Q o � FLAT ROOF SNOW LOAD - 36 PSF 2. OCCUPANCY AND CROUP: U SNOW LOAD IMPORTANCE FACTOR - 1,0 SNOW EXPOSURE FACTOR - 0.9 3, TY OF CONSTRUCTION: TY V - 1:3 THERMAL FACTOR - 1.0 4, LOCATION ON PROPERTY: WIND - 90 MPH (3 SEC GUST) EXP 5 EXTERIOR WALLS: NON -RATED WIND IMPORTANCE FACTOR - 1.0 WIND EXPOSURE - 5 (SOUTHWEST) .— EXTERIOR OPENINGS: NON -RATED WIND INTERIOR PRESSURE COEF - 0.31 5, OCCUPANCY SEPARATION : NOT REQUIRED SEISMIC USE GROUP - GROUP I SEISMIC CATEGORY - CLASSIFICATION D1 SPRINKLED: NO FLOOR LIVE LOAD - 40 PSF z NUM5ER OF STORIES: 1.0 Q FLOOR DEAD LOAD - 15 PSF >= (o, FIRE RESISTIVE REQUIREMENTS: uj I-- z ROOF DEAD LOAD - 15 PSF � p SEE ARCHITECTURAL DWGS o z O 443� � 1/ uj I CONTACTOR'S RESPONSIBILITY " THIS DRAWING IS FOR THIS LOCATION AND CUSTOMER IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL ASPECTS OF THESE DRAWINGS, M "" " ONLY AND IS NOT TO BE ARCHITECTURAL AND STRUCTURAL, PRIOR TO CONSTRUCTION, ANY CONFLICTS SHALL BE REPORTED TO THE ENGINEER FOR CORRECTION. CHANGES MAY BE PROPOSED BY THE REUSED WITHOUT T ANY MANNER THE WRITTEN CONSENT CONTRACTOR IF HE FEELS THE CHANGE IS IN THE BEST INTEREST OF THE OWNER, CHANGES OF DESIGN INTELLIGENGE.LLC. SHALL BE FORWARDED TO THE ENGINEER IN WRITING FOR APPROVAL PRIOR TO CONSTRUCTION. d FINISHED GRADE 12 —VINYL SIDING FRONT ELEV TION 1/4" 1' -O" FINISHED R1 HT ELEVATION 1/4" = 1' -O" LEFT ELEVATION SIMILAR TO RIGHT ELEVATION FINISHED GR REAR ELEV 710N 1/4" = i' -O" NOTE: ANY WALLS 10 FEET OR LESS FROM AN EXISTING BLDG OR PROPERTY LINE SHALL BE ONE HOUR CONSTRUCTION. L - - - - - - - - - - APPROX. HEIGHT OF R0001 TOP OF SHED WALLS SHEAR WALL NOTES: 1. ALL EXTERIOR WALLS ARE DESIGNATED SHEAR WALLS. 2. ALL FRAMED SHEAR WALLS SHALL BE 2x4 +0 24" O.C. 3. PROVIDE '1/19," APA RATED SHEATHING WITH Q 8D NAILS ai 4" O.C. AT PANEL EDGES AND r, 12" O.G. IN THE FIELD. BLOCKING IS REQUIRED AT ALL PANEL EDGES. 4. PROVIDE SIMPSON HOLDDOWNS AS SHOWN, INSTALL AS REQUIRED BY THE MANUFACTURER. SHED FINISHED FLOOR Cv rcc�c�r 'TIONAL) ULATED EXTERIOR _LS (OPTIONAL) SECTION X4,4 CONTACTOR'S RESPONSIBILITY IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL ASPECTS OF THESE DRAWINGS, ARCHITECTURAL AND STRUCTURAL, PRIOR TO CONSTRUCTION. ANY CONFLICTS SHALL BE REPORTED TO THE ENGINEER FOR CORRECTION, CHANGES MAY BE PROPOSED BY THE CONTRACTOR IF HE FEELS THE CHANGE IS IN THE BEST INTEREST OF THE OWNER. CHANGES SHALL BE FORWARDED TO THE ENGINEER IN WRITING FOR APPROVAL PRIOR TO CONSTRUCTION. r --------------- I i I I I I I 0 W I d - i Qr+Q'O QL z U+- I z � � ? Q i I N (L u- � O Q I (Xp� I O N U U P - 1 U m z Q Q (L 5_ () 1 U _` i �tOU�OF I I I Q (V �SIMPSON 5THD8 HOLDDOWN EACH SIDE OF SHED DOOR (TYPJ FOUNDATION PLAN 1/2" ANCHOR BOLTS SPACED m 48" O.C. MAXI W/ 3x3x1/4 SQR WASHERS FINISHED 2x FRAME WALL 2x PT BOTTOM PLATE CONT. 12X8 FOOTING WITH (2) 0 4 CONT. MONOLITHIC SLAB DETAIL O �p THIS DRAWING IS FOR THIS LOCATION AND CUSTOMER ONLY AND IS NOT TO BE REUSED IN ANY MANNER WITHOUT THE WRITTEN CONSENT OF DESIGN INTELLIGENCE.LLC. O O N In N 8 z cl 0 o �o z z 0 m w z O J Q Lu o CV p0 z , d LL uj z Q 0 O Q W � L r X � lU O p� U Q u1 d) .4 � Z 0 U u Z Q W 12' -0" SHED 4 4 IO' -O" x 10' -0" (o' 12' -0" MA IN FLOOR PL N 1/4" a 1' -0" 4 Q o � N 4 2x OUTLOOKER (TYP.) 2' - 0 " 12' -0" 11 Ell nn��I —VINYL SIDING FRONT ELEV TION 1/4" 1' -O" FINISHED R1 HT ELEVATION 1/4" = 1' -O" LEFT ELEVATION SIMILAR TO RIGHT ELEVATION FINISHED GR REAR ELEV 710N 1/4" = i' -O" NOTE: ANY WALLS 10 FEET OR LESS FROM AN EXISTING BLDG OR PROPERTY LINE SHALL BE ONE HOUR CONSTRUCTION. L - - - - - - - - - - APPROX. HEIGHT OF R0001 TOP OF SHED WALLS SHEAR WALL NOTES: 1. ALL EXTERIOR WALLS ARE DESIGNATED SHEAR WALLS. 2. ALL FRAMED SHEAR WALLS SHALL BE 2x4 +0 24" O.C. 3. PROVIDE '1/19," APA RATED SHEATHING WITH Q 8D NAILS ai 4" O.C. AT PANEL EDGES AND r, 12" O.G. IN THE FIELD. BLOCKING IS REQUIRED AT ALL PANEL EDGES. 4. PROVIDE SIMPSON HOLDDOWNS AS SHOWN, INSTALL AS REQUIRED BY THE MANUFACTURER. SHED FINISHED FLOOR Cv rcc�c�r 'TIONAL) ULATED EXTERIOR _LS (OPTIONAL) SECTION X4,4 CONTACTOR'S RESPONSIBILITY IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL ASPECTS OF THESE DRAWINGS, ARCHITECTURAL AND STRUCTURAL, PRIOR TO CONSTRUCTION. ANY CONFLICTS SHALL BE REPORTED TO THE ENGINEER FOR CORRECTION, CHANGES MAY BE PROPOSED BY THE CONTRACTOR IF HE FEELS THE CHANGE IS IN THE BEST INTEREST OF THE OWNER. CHANGES SHALL BE FORWARDED TO THE ENGINEER IN WRITING FOR APPROVAL PRIOR TO CONSTRUCTION. r --------------- I i I I I I I 0 W I d - i Qr+Q'O QL z U+- I z � � ? Q i I N (L u- � O Q I (Xp� I O N U U P - 1 U m z Q Q (L 5_ () 1 U _` i �tOU�OF I I I Q (V �SIMPSON 5THD8 HOLDDOWN EACH SIDE OF SHED DOOR (TYPJ FOUNDATION PLAN 1/2" ANCHOR BOLTS SPACED m 48" O.C. MAXI W/ 3x3x1/4 SQR WASHERS FINISHED 2x FRAME WALL 2x PT BOTTOM PLATE CONT. 12X8 FOOTING WITH (2) 0 4 CONT. MONOLITHIC SLAB DETAIL O �p THIS DRAWING IS FOR THIS LOCATION AND CUSTOMER ONLY AND IS NOT TO BE REUSED IN ANY MANNER WITHOUT THE WRITTEN CONSENT OF DESIGN INTELLIGENCE.LLC. O O N In N 8 z cl 0 o �o z z 0 m w z O J Q Lu o CV p0 z , d LL uj z Q 0 O Q W � L r X � lU O p� U Q u1 d) .4 � Z 0 U u Z Q W 12' -0" SHED 4 4 IO' -O" x 10' -0" (o' 12' -0" MA IN FLOOR PL N 1/4" a 1' -0" 4 Q o � N 4 2x OUTLOOKER (TYP.) 2' - 0 " 12' -0" 2' -0" L 12' -0" NON LIVING: = 192 SQ, FT, ICE BARRIER NOTES: PROVIDE AN ICE BARRIER THAT EXTENDS FROM THE EDGE OF THE EAVES TO A POINT NOT LESS THAN Q 24" INSIDE THE EXTERIOR WALL LINE OF THE BUILDING AND AT ALL VALLEYS. ROOF VENTILATION: PROVIDE ROOF VENTILATION 1 SF FOR EVERY 300 SF OF ATTIC SPACE, 1/2 HIGH AND 1/2 LOW, Q 0(0f= FRAMING 1/4" = r ----------- --- I I I I I I I I I I I I I I I -------- - - - - -I I I I I I I I I I I L_ 5EAM SCHEDULE W51 - (2) DF 2X8 TRUSS FRAMING NOTES: 1. INSTALL TRUSSES PER MANUFACTURER'S RECOMMENDATIONS INCLUDING ALL BRIDGING AND BRACING -c. 2, PROVIDE SIMPSON H1 OR EQUAL AT BRGz ENDS OF EACH TRUSS. 3, BEARING WALL HEADERS SHALL BE (2) DF 2x8 UNLESS NOTED OTHERWISE. 4. ALL ROOF OVERHANGS SHALL BE AS NOTED. A /! I11 I A I T I. I I♦ l i l 1— �� In � Ls - - - - - - - - - - - - - - - 'L J NINE liffli 1 M* 2' -0" L 12' -0" NON LIVING: = 192 SQ, FT, ICE BARRIER NOTES: PROVIDE AN ICE BARRIER THAT EXTENDS FROM THE EDGE OF THE EAVES TO A POINT NOT LESS THAN Q 24" INSIDE THE EXTERIOR WALL LINE OF THE BUILDING AND AT ALL VALLEYS. ROOF VENTILATION: PROVIDE ROOF VENTILATION 1 SF FOR EVERY 300 SF OF ATTIC SPACE, 1/2 HIGH AND 1/2 LOW, Q 0(0f= FRAMING 1/4" = r ----------- --- I I I I I I I I I I I I I I I -------- - - - - -I I I I I I I I I I I L_ 5EAM SCHEDULE W51 - (2) DF 2X8 TRUSS FRAMING NOTES: 1. INSTALL TRUSSES PER MANUFACTURER'S RECOMMENDATIONS INCLUDING ALL BRIDGING AND BRACING -c. 2, PROVIDE SIMPSON H1 OR EQUAL AT BRGz ENDS OF EACH TRUSS. 3, BEARING WALL HEADERS SHALL BE (2) DF 2x8 UNLESS NOTED OTHERWISE. 4. ALL ROOF OVERHANGS SHALL BE AS NOTED. A /! I11 I A I T I. I I♦ l i l 1— �� In � Ls - - - - - - - - - - - - - - - 'L J GE STR UCTURAL NOTES CODES AND SPECIFICATiONS A. International Building Code - 2003 Edition B. ACI 318 -02 Building Code Requirements for Reinforced Concrete GENERAL STRUCTURAL NOTES I, The Structural drawing shall be used in con,juction with the drawings of all other disciplines and the project specifications, The contractor shall verifiy the requirements of the other trades as to sleeves, chases, hangers, Inserts, anchors, holes and other items to be placed or set in the structural work, 2. The contactor shall be responsible for complying with all safety precautions and regulations during the work. The engineer will not advise on nor issue direction as to safety precautions and programs, 3. The structural drawings herein represent the finished structure. The contractor shall provide all temporary guying and bracing required to erect and hold the structure in proper alignment until all structural work and connections have been completed, The investigation, design, safety, adequacy and inspection of erection bracing, shoring, temporary supports, etc, is the sole responsibility of the contractor, 4, The engineer shall not be responsible for the methods, techniques and sequences of precedures to perform the work. The supervision of the work is the sole responal- bllfty of the contractor, 5. Drawings indicate general and typical details of construction, Where conditions are not specifically shown, similar details of construction shall be used, subject to approval by the engineer, 6, All structural systems which are to be composed of components to be field erected shall be supervised by the supplier during manufacturing, delivery, handling, storage and erection in accordance with the supplier's instructions and requirement&. 1, Loading applied to the structure during the process of construction shall not exceed the safe load - carrying capacity of the structural members, The live loadings used in the deafen of the structure are indicated in the "Design Criteria Notes ", Do not apply any construction loads until structural framing is properly connected together and until all temporary bracing is in place, 8, All ASTM and other references are per the latest editions of these standards, unless otherwise noted. 9, Shop drawings and other items shall be submitted to the engineer for review prior to fabrication , All shop drawings shall be reviewed by the general contractor before submittal. The engineer's review is to be For conformance with the design concept and general compliance with the relevant contract documents. The engineer's review does not relieve the contractor of the sole resposibility to review, check and coordinate the shop drawings prior to submission, The contractor remains coley responsible for errors and ommfesfons associated with the preparation of the shop drawings as they pertain to member sizes, details, dimensions, etc. 10. Submit shop drawings in the form of two blueline print$, In no case shall reproduction of the contract drawings be used as shop drawings. Submit the following items for review: A. Concrete mix designs) - NOT REQUIRED, B. Reinforcing steel shop drawings - NOT REQUIRED C. Structural steel shop drawings - NOT REQUIRED D. Steel Joist / Girder shop drawings - NOT REQUIRED E. Metal decking shop drawings - NOT REQUIRED F. Pre - manuf, wood aysem / truss shop drawings - NOT REQUIRED G. Pre - engineered metal building System - NOT REQUIRED Other submittals may be rquired per the "Schedule of Special Inspections" or the separate notes contained herein, Special Inspections will be required for this project as noted below: A, Concrete - NOT REQUIRED B, Bolts installed in Concrete - NOT REQUIRED C. Structural Welding - Field Welds - NOT REQUIRED D. High Strength Bolting - NOT REQUIRED E. Structural Masonry - NOT REQUIRED 12. Unless otherwise indicated, all Items noted to be demolished shall become the contractor's property and be removed from the aft *. 13. Contractors shall visit the site prior to bid to ascertain conditions which may adversely affect the work or cost thereof. DESIGN CRiTERiA Design Gravity Loads: Roof DL - 15 paf Floor DL - 15 paf Design Live Loads: Roof LL - 20 paf min Snow - SEE COVER SHEET Commerical Floor LL - 50 paf + 20 paf Partition Residential LL - 40 psi Lateral Live Loads: Wind - SEE COVER SHEET Seismic - SEE COYER SHEET Equivalent Fluid Pressure - 55 psF Bearing pressure assumed to be 1500 PSF for column and wall footfnga as per UBC Table 29 -5 based upon a sandy gravel and /or gravel soil. Any variations encountered, different from the oil type assumed, shall be brought to the attention OF the Engineer before proceeding, FOUNDATION NOTES I, All footings shall bear on undisturbed, firm natural soil or compacted fill capable of supporting a design bearing pressure of 1500 psF, All foundation excavations shall be evaluated by a qualified geotechical engineer /testing agency prior to pouring foundation concrete if required by the Structural Engineeer, 2, Top of footing elevations shall be as shown on the foundation plan. These elevations are a maximum and shall be lowered as required to obtain the required design bearing pressure. Unless noted otherwise, the bottom of all exterior footings shall be placed 6" below local frost depth: the bottom of all interior footings shall be placed 12" minimum below interior finished grade, 3. All foundation concrete shall obtain a 28 day compressive Strength of 2500 psi. All concrete to be permanentaly exposed to the weather shall be air - entrained to 5% ( +/- 111.) with an admixture that conforms to ASTM C -260. 4, All concrete work shall conform to the requirements of ACI 30, "Specification for Structural Concrete Buildings ", Hot weather concreting shall be in accordance with ACI 305, Cold weather concreting shall be in accordance with ACI 306, 5, All reinforcing steel shall conform to ASTM A -615, Grade 60 for 0 5 and larger and Grade 40 for 0 4 and smaller. 6, Unless noted otherwise, the following concrete cover shall be provided for reinforcement, A, Concrete cast against t permanently exposed to earth - 3" B, Concrete exposed to earth or weather, 0 6 through 0 18 bars - 2" "5 bar, W31 or D31 wire t smaller - 1 1/2" 1, All reinforcing marked continuous (Cont.) on the plans and details shall be lapped 36 X bar diameters at splices unless noted otherwise, 8. No unbalanced backFilline shall be done against foundation walls unless walls are securely braced against overtrunine, either by temporary bracing or by permanent construction, 9. Prior to commencing any foundation work, coordinate work with any existing utilities, Foundations shall be lowered where required to avoid utilities. 11. Unless noted otherwise, the centerlines of column foundations shall be located on column centerlines, 10, All retaining walls shall have at least 12" of free draining granular backf111, Full height of wall. Provide control ,Joints In retaining walls at approximately equal intervals not to exceed 25 feet nor 3 times the wall height. Provide expansion ,Joints at every fourth control Joint, unless otherwise indicated. SITE PREPARATiON NOTES I, Withn an area a minimum of 5 feet beyond the building limits, excavate a minimum of 4" of existing soil, Remove all organics, pavement, roots, debris and otherwise unsuitable material. 2, The surface of the exposed subgrade shall be inspected by probing or testing to check for pockets of soft or unsuitable maerial. Excavate unsuitable soil as directed by the engineer, 3. Proof roll the surface of the exposed $ubeade with a loaded tandem axle dump truck. Remove all soils which pump or does not compact properly as directed by the engineer. 4. Fill all excavated areas with approved controlled fill, Place in 8" loose lifts and compact to a minimum of 95% of the maximum dry density In accordance with ASTM D -698, 5, All controlled fill material shall be a select granular material free from all organics or otherwise deleterious material with not more than 20% by weight passing a no. 200 sieve and with a placticity index not to exceed 6q, CONTACTOR'S RESPONSIBILITY 6, Provide field density tests for each 3,000 SF of IT IS THE CONTRACTOR'S RESPONSIBILITY TO REVIEW ALL ASPECTS OF THESE DRAWINGS, building area for each lift of controlled fill, ARCHITECTURAL AND STRUCTURAL, PRIOR TO CONSTRUCTION. ANY CONFLICTS SHALL BE REPORTED TO THE ENGINEER FOR CORRECTION, CHANGES MAY BE PROPOSED BY THE CONTRACTOR IF HE FEELS THE CHANGE IS IN THE BEST INTEREST OF THE OWNER. CHANGES SHALL BE FORWARDED TO THE ENGINEER IN WRITING FOR APPROVAL PRIOR TO CONSTRUCTION, PRE- ENGINEERED TRUSS NOTES 1. Wood trusses shall be designed by the manufacturer to support the loads dictated by the governing ,jurisdiction, 2. Wood trusses shall be designed by the maufacturer in accordance with the applicable provisions of the latest edition of the National Design Specification of the National Forest Products Association and the design specification for metal plate connected wood trusses of the Truss Plate Institute. 3. Wood materials shall be Douglas Fir and shall be kiln dried and used at 19% maximum moisture content. Provide grade required to meet stress requirements, 4, Connector plates shall be not lase than 0,036 inches (20 gage) in coated thickness, shall meet or exceed ASTM Grade A or higher and shall be hot dipped galvanized according to ASTM A -525 (coating G60), Minimum steel yield stress shall be 33,000 psi, 5. Trusses shall be fabricated in a properly equipped manufacturing facility of a permanent nature. Trusses shall be manufactured by experienced workmen, using precision cutting, ,jigging and pressing equipment under the requirements in quality control standard Q5T -88 of the Truss Plate institute, 6, Secondary bending stresses in truss top and bottom chords due to dead, live and wind loods shall be considered in the design. Load duration factors shall be per the "National Deafen Specification for Wood Construction" latest edition, 1. Wood trusses shall be erected in accordance with the truss manufacturer's requirements, This work shall be done by a qualified and experienced contractor, S. The Contractor shall provide all temporary and permanent bracing as required for safe erection and performance of the trusses. The guidelines set forth by the Truss Plate Institute publication "HIB -91, Commentary and Recommendations for Handling, Installing and Bracing Metal Plate Connected Wood Trusses" shall be a minimum requirement. 9, Truss member and components shall not be cut, notched drilled nor otherwise altered in any way without the written approval of the Engineer, 10. Submit complete shop drawings for all wood trusses showing member sizes, species, grade, moisture content, span, camber, dimensions, chord pitch, bracing requirements and loadings, Shop drawing shall be submitted to the Engineer and shall bear the seal of a Professional Engineer registered in Idaho. WOOD FRAMING NOTES 1. All wood framing material shall be surfaced dry and used at IS9. maximumu moisture content, 2. All stud and wall framin shall be No, 2 grade Doug Fir, 3. All ,joist, rafter E misc, framing shall be No. I grade Doug Fir, Provide full depth or metal bridging at midapan and at a maxmfmum spacing of 8 ft o.c, between. 4. All framing exposed to the weather or in contact with masonry or concrete shall be pressure treated in accordance with the American Wood Preservers Aeeocicatfon Specifications where possible. All cuts and holes should be completed before treatment. Cuts and holes due to on -site fabrication shall be brushed with 2 coats of copper naphthenate solution containing a minimum of 29. metallic copper In solution (per AWPA STD, M4), 1. Provide double ,joists under all partitions which run parallel with ,Joists and under all concentrated loads from framing above. 8, Provide header beams of the same size as ,Joists or rafters to frame around openings in the plywood deck unless otherwise indicated, S. Structural steel plate connectors shall conform to ASTM A -36 specifications and be 1/4" thick unless noted otherwise, Bolts connecting wood members shall be ASTM A -301 and be 3/4" diameter unless otherwise Indicated. Provide washers for all bolt heads and nuts in contact with wood surfaces. 10. Bolt holes shall be carefully centered and drilled not more than 1116" larger than the bolt diameter, Bolted connections shall be snugged tight but not to the extent of crushing wood under washers, II. Prefabricated metal ,joist hangers, hurricane clips, hold -down anchors and other accessories shall be as manufactured by "Simpson Strong -Tie Company ", or approved equal. Install all accessories per the manufacturer's requirements, All steel shall have a minimum thickness of 0.04 inches (per ASTM A446, Grade A) and be galvanized (coating G60). 12, Holes and notches drilled or cut into wood framing shall not exceed the requirements of 2003 international Building Code Section 23, 13, All plates, anchors, nails, bolts, washers and other miscellaneous hardware permanentaly exposed to weather shall be hot dip galvanized, SLAB ON GRADE NOTES I, Provide concrete slabs over a 6 mil polyethylene vapor barrier and 4" of porous Fill. Maximum slump for concrete slabs shall be 5 ", using Type II cement, 2. All porus fill material shall be a clean granular material with 100% passing a 1 -1/2" sieve and no more than 5% passing a No. 4 sieve. Porous fill shall be compacted to 95% max, dry density per ASTM D-698. 3. Slab Joints shall be filled with approved material. This should take place as late as possible preferably 4 to 6 weeks after the slab has been cast. Prior to filling, remove all debris from the ,joints, then fill in accordance with the manufacturer's recommendations as follows: 6" slabs - fill with Epoxy resin Other slabs - fill with field molded of elastomerfc sealant, 5. Unless approved otherwise, all reinforcing shall be blocked into the center of the slab with precast concrete blocks having a compressive strength equal to that of the slab, 6. Walk ways and other exterior slabs are not shown on the structrual drawings. See the site plan and architectural drawings for location, dimensions, elevations, ,Jointing details and finish details, Provide 4" walks reinforced with 6x6 - W1,41111,4 WWF unless otherwise noted, 1. Slabs to be permanently exposed to weather shall be air entrained to 5% (+/- 1%) with an admixture that conforms to ASTM C -260, 8, All concrete work shall conform to the requirements ACI 301, "Specification for Structural Concrete Buildings ", Hot weather concreting shall be in accordance with ACI 305, Cold weather concreting shall be in accordance with ACI 306, 9, In order to avoid concrete shrinkage cracking, place concrete slabs in an alternating lane (or checker board) pattern, The maximum length of slab cast in in any one continuous pour is recommended to be less than 100 feet, The maximum spacing of ,joints shall be 25 feet, 10. See architectural drawings for exact locations of depressed slab areas and drains, Slope slab to drains where shown, 11, The finish tolerance of all slabs shall be in accordance with ACI 301, Type A. 12, Slabs shall be constructed in accordance with the following fiatneee /levelness requirements: Slab Category Specified Local Minimum Bull- Floated Ff ■ 15 , FI • 13 Ff ■ 13 , FI ■ 10 Straight Edged Ff 15 , FI 13 Ff ■ 13 , FI ■ 10 Flat Ff 15 FI 13 Ff■13,FI.10 0 4 a 18" o,c Very Flat Ff ■ 15 , FI ■ 13 Ff ■ 13 , FI ■ 10 Super Flat Ff F1 13 Ff Floor flatness and levelness tests shall be conducted if deemed necessary by the owner in accordance with ASTM E 1155. Results, including acceptance or refection OF the work will be provided to the contractor within 48 hours after data collection, Remedies for out of tolerance work may include removal and reconstruction at the contractors expense. Any other remedlation requiree the approval of the owner, PLYWOOD /GYP"50ARD SHEATHING NOTES i, All plywood construction shall be in accordance with the American Plywood Association (APA) specifications, 2. All roof panel sheathing shall be 5/8" (nom.) OSB 1 APA rated Sheathing, Suitable edge support shall be provided by use of panel clips or blocking between framing, Unless otherwise noted connect roof sheathing with 8d common nails at 6" o,c, at supported panel edges and 6" o.c, at intermediate supports, 3, All floor sheathing shall be 3/4" (nom.) APa rated STURD -I -FLOOR Exp. I, with tongue and groove edge. Unless noted otherwise connect floor sheathing with IOd common nails spaced 6" o,c. supported edges and 12" o,c. at intermediate supports. Field glue using adhesives meeting APA specification AFG -01, applied in accordance with the manufacturer's recommendations, 4. All wall sheathing shall be 1/2" (nom.) OSB APA rated sheathing. Unless noted otherwise, connect wall sheathing with 8d common nails spaced at 6" o,c. at supported panel edges and 12" o.c at intermediate supports, 5. Install all plywood sheathing with the long dimensions of the panel across supports and with panel continuous over two or more Spans, stagger panel end Joints. Allow 1/8" spacing at panel ends and edges unless otherwise recommended by the sheathing manufacturer, 6. All nailing shall be carefully driven and not over - driven. 1. Provide 2x blocking at all unsupported panel edges, CAST -iN -PLACE CONCRETE NOTES I. Concrete mixes shall be designed per ACI 301, using Portland Cement conforming to ASTM C -150 or C -595, aggregate conforming to ASTM C -33, and admixtures conforming to ASTM C -494, C- 1011, C -618, C -989 and C -260. Concrete shall be ready -mixed in accordance with ASTM C -94, 2, Concrete shall conform to the following compressive strength, slump and water /cement ratio requirements unless specifically approved by the Engineer In writing: Concrete Min f'c (28 days) Slump WIC Ratio Columns 4000 psi 2 - 4 0,46 Elevated Slabs 3000 psi 2 - 4 0.46 Concrete not Noted 3000 psi 2" - 4 0,50 Foundations 2500 psi 2 - 4 0.50 Slabs on Grade 4000 psi 2 - 4" 0.50 3. All concrete work shall conform to the requirements of ACI 301, "Specification for Structural Concrete Buildings ", Hot weather concreting shall be in accordance with ACI 305, Cold weather concreting shall be in accordance with ACI 306. 4, All reinforcing steel shall conform to ASTM A -615, Grade 60 For 0 5 and larger bare and Grade 40 for 0 4 and smaller. All welding of reinforcing steel shall be in accordance with AWS D1,4, Epoxy coated reinforcing shall conform to ASTM A -115. 5. All welded wire fabric (WWF) shall conform to ASTM A -185, 6. All reinforcing steel shall be set and tied in place prior to pouring of concrete, except that vertical dowels for masonry wall reinforcing may be "floated" in place, Do not Field bend bars partially embedded In hardened concrete unless specifically indicated or approved by the Engineer, 1. Reinforcing steel, including hooks and bends, shall be detailed in accordance with ACI 315, All reinforcing steel indicated as being continuous (Cont,) shall be lapped with a Type 2 splice unless noted otherwise. S. Unless noted otherwise, the following minimum concrete cover shall be provided for reinforcement: A. Concrete exposed to earth or weather: •6 through »18 bars - 2" 0 5 bar, W31, D31 wire t smaller - 1 1/2 B. Concrete not exposed to earth or weather: Walls, elevated slabs It ,joists] - 3/4" Beams and columns - 1 1/2" C. Foundation concrete - See Foundation Notes. S. Bar supports and holding bars shall be provided for all reinforcing steel to Insure minimum concrete cover. Bar supports shall be plastic tipped or Stainless steel, 10, Unless noted otherwise, all one way slabs shall be reinforced as follows: Bottom reinforcing 0 4 +0 16" o,c, (Between Supports) Top Reinforcing •4 A 12" o,c, (Centered on Supports) Temp, Reinforcing 0 4 A 18" o,c. (Transverse Bottom) 11, Unless noted otherwise, all concrete walls (other than retaining walls) shall be reinforced as follows: Wall Thickness Horizontal Vertical Location 4 - 6 " 0 4 * 16" o,c, 0 4 0 18" o,c. Centered 8" 0 4 6 12" o,c. 0 4 * 18" o,c, Centered 10" 0 4 0 18" o,c, 0 4 a 18" o,c Each Face 12" 0 4 0 16" o.c, 0 4 c 18" o,c, Each Face 12, All edges of permanently exposed concrete surfaces shall be chamfered 3/4" unless otherwise noted, 13, in order to avoid concrete shrinkage cracking, place concrete slabs in an alternating lane pattern, The maximum length of slab cast in any one continuous pour shall be limited to 80 feet, 14. Formwork shall remain in place until concrete has obtained at least SO% of its 28 day compressive strength. The Contractor shall provide all shoring and reshorine, O STRUCTURAL STEEL NOTES vJ 3, Minimum bolt diameter shall be 3/4" unless noted otherwise. All bolts shall be shear /bearing type bolts and be enug tight. 4. All welding shall be in accordance with AWS DI.I using EIOXX O O I, All structrual steel shall conform to the latest edition of the per requirements. filler material O "Manual of Steel Construction" of the AISC, shall have a minimum yield strength of 58 kal, "Continuous z (y 0 2, Unless noted otherwise, all materials shall be in conformance 0 a continuous butt weld or full penetration weld at the splice with the Following ASTM specifications: connection detail for approval, 6 . Moment connections are denoted thus ( ) on the m CL z w z d) 1. Where steel beams bare across building expansion ,joints i 3 Q ul DO D MEMBER ASTM MIN, STRENGTH Q LU Q Structural Tubing A500 Grade B 46 kei Steel Pipe A53 (Type E or Grade B) 35 ksi Other Rolled Shapes r Q all structural steel permanently and Plates A36 36 ksf SSPC 15 -68 Type I (Red Oxide) paint, Connection Bolts A325 92 ksf guying and bracing. Anchor Bolts A301 - - -- Q For the loading encountered during steel erection and Threaded Rods A36 36 ksf construction. Any investigation of the columns, anchor bolts, base etc, is the Non- Shrir:k Grout C1101 8000 psi 12, Steel fabricators shall be an AISC certified shop for Category I steel structures and maintain detailed quality UJ IH I4_ 3, Minimum bolt diameter shall be 3/4" unless noted otherwise. All bolts shall be shear /bearing type bolts and be enug tight. 4. All welding shall be in accordance with AWS DI.I using EIOXX O electrodes, Unless noted otherwise, provide cont, min, sized Fillet welds AISC All O per requirements. filler material O shall have a minimum yield strength of 58 kal, "Continuous z (y 5, Where Chord" angles are indicated, provide a continuous butt weld or full penetration weld at the splice connection detail for approval, 6 . Moment connections are denoted thus ( ) on the m O plan. See typical details, w z 1. Where steel beams bare across building expansion ,joints i 3 Q O or at wall control ,Joints, provide a "slip" connection as shown 0 in the typical details. 8, Holes in steel shall be drilled or punched. All Slotted holes shall be with provided smooth edges, Burning of holes and torch cutting at the site 1s not permitted, 9, Unless otherwise noted, r Q all structural steel permanently exposed to view shall be shop painted with one coat of SSPC 15 -68 Type I (Red Oxide) paint, SID to 10, The structural steel erector shall provide all temporary guying and bracing. ii. Columns, anchor bolts, base plates, etc, have been designed Q For the loading encountered during steel erection and C4 construction. Any investigation of the columns, anchor bolts, base etc, is the plates, sole responsibility of the contractor. Z d 12, Steel fabricators shall be an AISC certified shop for Category I steel structures and maintain detailed quality UJ IH I4_ control procedures as required to satisfy the special . �} inspection requirements of the 2003 International Building V Code. -� 13. Provide eirts with a slight downward "bow" at midapan. 14, Unless otherwise noted, all structural steel permanently exposed to the weather, including all brick Shelf angles shall be hot - dipped galvanized in accordance with ASTM A153, 15, Protective coatings damaged during the transporting, L erecting and field welding processes shall be repaired T C1 in the field to match the Shop applied coating, 16. The contractor shall hire an independent testing agency to provide special inspections of bolting, welding and Q other items in accordance with 2003 International Building Code. O Q 11, Provide angle frames at all roof openings and mechanical to roof top units per typical details, a �� r X O � 0 Q lu ~ Z N Q y�paVA� EN ti �G% TER �.. i3 4463 M Z ry 10�Y� X �? 0. � G THIS DRAWING IS FOR THIS LOCATION AND CUSTOMER ONLY AND IS NOT TO BE REUSED IN ANY MANNER WITHOUT THE WRITTEN CONSENT OF DESIGN INTELLIGENCE.LLG,