HomeMy WebLinkAboutPLANS & LETTERS - 06-00204 - Express Wash Car Wash - Site Plan0 0 a N 0 0 N C N N U 0 Q U CD N 0 0 y a 0 0 0 3 U 0 0 0 0 Y 18 z 0 —i N z 0 3 c V / f� f 3 f i s E t { } p £ { z 5 f A w� I IE 4861.63 N 792777.94 E 758759.94 3, s J s , CONSTRUCTION NOTES i _r: 7f :j Q 0 :5 F i g � z 0 —i N z 0 3 c V / f� f 3 f i s E t { } p £ { z 5 f A w� I IE 4861.63 N 792777.94 E 758759.94 3, s J s , 12. INSTALL THRUST CONSTRUCTION NOTES ALL 9ENDS IN, _r: 7f � Q 0 Z g � 0 Z ce 0 1. DIMENSIONS TO, OR COORDINATES FOR, MANHOLES, RES s RAii, 0 w PIPELINES, ETC., ARE TO CENTERLINE UNLESS z OTHERWISE NOTED. 3 2. ELEVATIONS SHOWN ARE TO FINISHED SURFACE OR PIPE INVERT UNLESS OTHERWISE NOTED. O 3. GENERAL LOCATION OF UTILITIES ARE SHOWN ON THE PLANS. THEY ARE TO BE USED FOR o p to GENERAL INFORMATION ONLY AND DO NOT a Z DESIGNATE EXACT UTILITY LOCATION. UTILITIES 0 O SHOWN ARE NOT INCLUSIVE OF ALL UTILITIES cn w in V) THAT EXIST. IT IS THE RESPONSIBILITY OF THE w 20' 10' 0 20' CONTRACTOR TO NOTIFY THE APPROPRIATE D! UTILITY COMPANIES WHEN CONSTRUCTION MIGHT INTERFERE WITH NORMAL OPERATION OF ANY SCALE = 1" = 20' UTILITIES. IT SHALL ALSO BE THE CONTRACTOR'S RESPONSIBILITY TO HAVE THE APPROPRIATE ° z UTILITY COMPANY FIELD - LOCATE ANY UTILITY INSTALLATIONS WHICH MIGHT BE AFFECTED BY CONSTRUCTION PRIOR TO BEGINNING WORK IN 0 THAT AREA. THE CONTRACTOR SHALL BE In 't RESPONSIBLE FOR MAINTAINING SERVICE OF Z U Q EXISTING UTILITIES AND FOR RESTORING ANY U ? W 00 UTILITIES DAMAGED DUE TO CONSTRUCTION. z o 4. ALL UTILITY LINES ARE TO BE LOCATED AS SHOWN ON THE W PLANS UNLESS RELOCATED IN o Q THE FIELD BY THE ENGINEER TO AVOID �/� H UNFORESEEN UTILITY INTERFERENCE. V 00 5. THERE SHALL BE A 10 FOOT MINIMUM HORIZONTAL O Z SEPARATION DISTANCE BETWEEN ALL EXISTING O m WATER LINES AND NEW SEWER LINES EXCEPT Q 0 WHERE WATER AND SEWER LINES CROSS AT x APPROXIMATELY RIGHT ANGLES, WHERE A MINIMUM OF 1.5 FEET OF VERTICAL SEPARATION SHALL BE III MAINTAINED. IIIIII 6. MINIMUM CLEARANCE BETWEEN NEW PIPELINES AND EXISTING UTILITIES AND STRUCTURES (EXCEPT WATER LINES) SHALL BE TWO FEET HORIZONTALLY. 7. MINIMUM DEPTH OF COVER FOR WATER AND SEWER LINES UNLESS OTHERWISE SHOWN ON THE PLANS SHALL BE FIVE (5) FEET. Z }' O 8. PIPE MATERIAL FOR THIS PROJECT SHALL BE: — GRAVITY SEWER- ASTM D3034 SDR 35 PVC PIPE Q Z O 8" THROUGH 10" WATER LINE- C -900 CLASS 150 Z LL_ = Cr PVC PIPE OR HDPE PIPE O p J O N U 9. CONTRACTOR SHALL PROVIDE ANY GROUNDWATER LU Z Z W DEWATERING TO CONSTRUCT THIS PROJECT. CL O U 10. PROVIDE TRENCHING FOR ALL LINES PER ISPWC -2000 EDITION STANDARD DRAWING SD -301. � li 11. PROM JE FOR W N r ER ANO SE °,ER SEimAPA a ION LIN P �: WHERE y :a �yd°,.r� _ ±a ED ik,a z I Sn 12. INSTALL THRUST FLOCKS AT ALL 9ENDS IN, _r: 7f � 0 Z g � Z ce ANiCAL RES s RAii, RECOMMENDATIONS. 13 CONNECT NEW 10" SANITARY SEWER LINE TO EXISTING 10" SEWER LINE. CONTRACTOR TO VERIFY LOCATION AND INVERT OF EXISTING LATERAL AND NOTIFY ENGINEER IF DIFFERENT THAN THAT SHOWN ON PLANS. 14 CONNECT NEW 12" WATER LINE TO EXISTING 9 WATER LINE. 15 TERMINATE 12" WATERLINE WITH 12" CAP. 16 CONNECT TO WATER SERVICE LINE, SEE MECHANICAL SHEETS FOR LOCATION. : 17)GREASE TRAP AND SEDIMENT SEPARATOR TO BE SIZED BY OTHERS. ; ,z a. mww _r: 7f ��...__�...�..M,..�..�.._. ._� .. �m_ �. __._...��..M......�...�,.,.,..� .N .. �,.,,,. W.,. ��.......�........wuv.�dKK_a,�.. w..... ._ �,. �., ��.k. H ..,.,v..�.,.,.�.V.........,..�µ �.:. �...�...�.�.�.u..w�m�.�„ �,� ...�.�.x.�.�. .�r�..�.�.....� ��.. 3 EAST 7TH NORTH ST 18 EXISTING FIRE HYDRANT 290 FEET SOUTH OF SOUTH WEST PROPERTY CONER (SOUTH OF 7TH NORTH ST) AND 170 FEET SOUTH WEST OF SOUTH WEST PROPERTY CORNER, (WEST SIDE OF NORTH 2ND EAST). a CONTACTOR TO INSTALL A 2" MIN DIAMETER VENT FROM TEST MANHOLE TO INSIDE WALL OF MECHANICAL ROOM. TYPICAL TRENCH DETAIL PER ISPWC SD -301 STANDARD DRAWNG. INTSALL 1 -1/2" WATER SERVICE METER SD -402 PER ISPWC STANDARD DRAWING. THRUST BLOCK AND ANCHOR DETAILS ( PER ISPWC STANDARD DRAWING. �� mm NON- POTABLE WATER LINE SEPERATION SD -407 PER ISPWC STANDARD DRAWING. SD -501 INSTALL SEWER MANHOLE PER ISPWC STANDARD DRAWING. SD -512 TERMINATE SEWER LINE PER ISPWC STANDARD DRAWING. WARNING LINE IS 2 INCHES w AT FULL SIZE F NOT 2" —SCALE ACCORDINGLY co ti w cri 19 -n C N ol U 0 Z O w Z ce ol 0 Q 0 0 0 O a U N 0 0 2 0 0 3 0 U d O O cD O I O QJ Y >' i A. SD -701 A:) LAST ROUNDUP ANTIQUES ,_ 20' 10' 0 20' Lk O 1 SCALE = 1" = 20' c o tK' µ. W M , I" . r • .. ,....� , .. ........ r w 709 Al <'. ..-- SD -8701 SD 1�" -HDPE ' 7 h 6 FF 73.50 1�• goo 7 fn vw az� 7 - 601 SD SD -701 A } u SD 603 N =SD 73 ' SD- -301 C -12'" -HDPE .. : - � SD- 12 "- HDpE�, 1 z F t 7 SO -301 m 4 r 'h � ^a - c. 1 SID -01° }'� �'1.' .tom 9 � ✓- , � ° r. , - • -.- r � �?a ,.�- ;•,• �°�` i!`�� .z��r' ,�'�i` . ac t`� , ;,�* s ,. —�� yq . J A w�cv'mel�'n�= ":ig " .: ....,�. ..• e - °�'� %9 ,. -. .. ., �" ^� • 'S �. - ...d ..: ,J y 3� J � a � a x3, yr�Y+ z._v.., :'.r_�.c..;• ... 'a.:: ,:, "�,. ,. - ;}� .:��.,""" , + ': _ - � .� ' �. � '� •, L v�r<'!.l y'$S`�,,,. _"�.?'v ,1as'acd'., � 3 :.welt .,::... , .� „r ass _ _.. mew ■oo a�sa, .�aRx?snn��..esx�r r �m sa __ . ¢ ,: Y. rim.._.,... c._, SD —il✓ �' $ � '°` EXISTING 2' Hlk RETAINING WALL rA y . f ` 3 � FF 74.00 # ? ate, r , ..:,✓T f # s S F :. 5.,.: '•:,„$ ( ; A , y 5 1 rnr i rl\ GRADING AND DRAINAGE PLAN PROPERTY OR R/W LINE LAND USE PROPOSED MAN HOLE O SCALE: 1 ” =20' CONTOUR LINE - 4250 - PROPOSED FIRE HYDRANT VOLUME SQ FT RAINFALL INTENSITY (IN /HR) PEAK FLOW (CFS) EXIST STORM DRAIN LINE »H. ° H . _, ._ `~ , {..H_ : °.. _ PROPOSED CATCH BASIN ■ ABBREVIATIONS EXIST WATER LINE - -- f, °- POLE &ANCHOR "" °"° °` ` "' FF FINISHED FLOOR ELEVATION 0.08 "' 0.92 2.3 TBC TOP BACK OF CURB EXIST GAS LINE ...�"�..-- °.�.- 5 < °' .-. ° °�`� „ °�° :.; STRUCTURE 0.64 64.3 0.90 2.3 4772 FL FLOW LI N E EXIST TELEPHONE CABLE ' .u:...._.: ° ° °N = ' < EXIST CURB &GUTTER 2.3 TA TOP OF ASPHALT " TC TOP OF CONCRETE EXIST ELECTRIC LINE EXIST SIDEWALKS mm TG TOP OF GRADE EXIST MANHOLE O SIGN `f % SD STORM DRAIN CP1 O EXIST EXISTING PROPOSED CURB AND GUTTER CONTROL POINT W WATER PROPOSED SIDEWALK w IDAHO STANDARD FOR SD - XXX S SEWER PUBLIC WORKS (ISPWC) - 2000 EDITION STANDARD PE POLYETHYLENE DRAWING NUMBER DESIGN CRITERIA LAND USE DRAINAGE (* YEAR EVENT) AREA SQUARE FOOTAGE ACREAGE PERCENT OF TOTAL RUNOFF COEFFICIENT RAINFALL DEPTH (INCHES) VOLUME SQ FT RAINFALL INTENSITY (IN /HR) PEAK FLOW (CFS) TOTAL 43015 0.99 100 0.71 2.3 5857 3.4 2.39 TOTAL BUILDING 3597 0.08 8.4 0.92 2.3 634 TOTAL IMPERVIOUS 27662 0.64 64.3 0.90 2.3 4772 [ — TOTALLANDSCAPED 11756 0.27 27.3 0.20 2.3 451 * 50 -YEAR FOR VOLUME CALCULATION, 10 -YEAR FOR PEAK FLOW CALCULATION. PEAK FLOW BASED ON COMPOSITE C =0.71. CONSTRUCTION NOTES: 0 1. DIMENSIONS TO /OR COORDINATES FOR MANHOLES, Y PIPELINES, ETC, ARE TO CENTERLINE UNLESS OTHERWISE NOTED. w Z 2. ELEVATIONS SHOWN ARE TO FINISHED SURFACE OR PIPE INVERT UNLESS OTHERWISE NOTED. Q o! 3. ALL STORM DRAIN LINES ARE TO BE LOCATED AS SHOWN ON THE PLANS UNLESS RELOCATED IN THE FIELD BY THE OWNER TO AVOID UNFORESEEN F UTILITY INTERFERENCE. p Z i' p 4. THERE SHALL BE A 10 FOOT MINIMUM HORIZONTAL w V) SEPARATION DISTANCE BETWEEN ALL EXISTING o w WATER LINES AND NEW SEWER LINES EXCEPT ui WHERE WATER AND SEWER LINES CROSS AT APPROXIMATELY RIGHT ANGLES, WHERE A MINIMUM OF 1.5 FEET VERTICAL SEPARATION SHALL BE MAINTAINED. o z 5. GENERAL LOCATION OF UTILITIES ARE SHOWN ON THE PLANS. THEY ARE TO BE USED FOR GENERAL INFORMATION ONLY AND DO NOT DESIGNATE EXACT F - 0 UTILITY LOCATION. UTILITIES SHOWN ARE NOT Z `j Q INCLUSIVE OF ALL UTILITIES THAT EXIST. IT IS THE po RESPONSIBILITY OF THE CONTRACTOR TO NOTIFY ? W 00 THE APPROPRIATE UTILITY COMPANIES WHEN (y Z CONSTRUCTION MIGHT INTERFERE WITH NORMAL �L. OPERATIONS OF ANY UTILITIES. IT SHALL ALSO BE V W N O THE CONTRACTORS RESPONSIBILITY TO HAVE THE v I� = Q APPROPRIATE UTILITY COMPANY FIELD LOCATE ANY 0 UTILITY INSTALLATIONS WHICH MIGHT BE AFFECTED BY CONSTRUCTION PRIOR TO BEGINNING WORK IN O Z w THAT AREA. THE CONTRACTOR SHALL BE 0 m RESPONSIBLE FOR MAINTAINING SERVICE OF EXISTING UTILITIES AND FOR RESTORING ANY I' Q Lo W UTILITIES DAMAGED DUE TO CONSTRUCTION. `� po D: 6. MINIMUM CLEARANCE BETWEEN NEW PIPELINES AND III 111111 EXISTING UTILITIES AND STRUCTURES (EXCEPT WATER LINES) SHALL BE TWO FEET HORIZONTALLY. 7. MINIMUM DEPTH OF COVER FOR STORMDRAIN LINES UNLESS OTHERWISE SHOWN ON THE PLANS SHALL BE TWO (2) FEET. 8. PIPE MATERIAL FOR THIS PROJECT SHALL BE: SEWER GRAVITY LINE - ASTM D3034 >- O SDR 35 PVC Q x F- Z WATERLINE - C -900 CLASS 150 PVC Z O U PIPE u- Z) � p0 STORM DRAIN - HDPE J O U 9. CONTRACTOR SHALL PROVIDE ANY GROUNDWATER Z Z uj DEWATERING NECESSARY TO CONSTRUCT THIS CL O PROJECT. qk 1 TYPICAL TRENCH DETAIL PER ISPWC � M a. SD-30 STANDARD FaRf- 4,N u r as " :) , -r : I L L C UR S AN r, — 7 PER L'F ;y s1:i`"' a S iii �1J�id "'� ,.a?r�'� s. !. -r ! " (S ID-7 , 01,1 ;NS,?I�L 6 VERTIC;a,L ,LAP SJ B r° 3 I t f3l�tiWV ' ' d 1 " SD -704 INSTALL CURB AND GUTTER TYPE 'i m a w z (ROLL GUTTER) PER ISPWC STANDARD ° ' ° " DRAWING. SD -709 INSTALL SIDEWALK PER ISPWC STANDARD DRAWING SD -601 INSTALL CATCH BASIN PER ISPWC C STANDARD DRAWING WITH SD -610 STANDARD GRATE. SD -603 INSTALL CATCH BASIN PER ISPWC STANDARD DRAWING WITH SD -610 STANDARD GRATE. O 1 RELOCATE TRAFFIC SIGN BEHIND NEW SIDEWALK. COORDINATE WITH IDAHO TRANSPORTATION DEPARTMETN IN RIGBY. O 2 MATCH TOP OF ASPHALT AND MATCH TOP BACK OF CURB WITH BACK OF WALK. TRANSITION INTO FULL CURB AND GUTTER. O 3 MATCH TOP OF ASPHALT WITH BACK OF ROLL GUTTER AND MATCH TOP BACK OF CURB WITH 1 7 1 1 BACK OF ROLL CUTTER THEN TRANSITION INTO FULL CURB AND GUTTER. 4 MATCH EXISTING TOP OF CONCRETE. A 5 EXTEND EXISTING DRIVEWAY APPROACH 7 FEET A TO SOUTH. O EXTEND SIDEWALK TO BACK OF EXISTING DRIVEWAY APPROACH FOR LAST ROUNDUP ANTIQUES. ti A O CONCRETE ISLAND FOR VACUUM EQUIPMENT SHALL BE DESIGNED AND LOCATED BY OTHERS. O EQUIPMENT PAD AND DUMPSTER ENCLOSURE TO BE DESIGNED AND INSTALLED BY OTHERS. U o WARNING 0 ,. z UNE IS 2 INCHES AT FULL SIZE N z cr- (IF NOT 2' -SCALE ACCORDINGLY Y y a N 0 O O N N N N U r_n Q U N 0 O 2 0 0 0 U O O a I 0 v: 0 Y 758707.08 N 792772.98 ELEV. 4871 [ T: ]rj�> % 12.06 I� 0 N 792767.37 E 758975.00 E 4 N < C4 . CHORD- BEARING CHORD Cl 16.45 10.50 S44 "E m, .. N 792767.48 30.63 19.50 N44'48'21 "W 27.58 C3 30.63 "a E 758885.40 N45'1 1'39 "E 27.58 r 16.40 10.50 N 792756.94 Y. N 7927 C5 30.80 19.50 S45 "E 27.70 E 758768.88 E 758885.51 2.00 S44 "W 2.82 C7 3.15 2.00 N45'09'24 "W 2.84 C8 43.35 27.50 N45'09'24 "W N 792730.30 C9 6.25 4.00 w 5.64 C10 E 758769.97 10.00 N67'11'12 "E 7.65 _.�.m....H.._._ �, ...� 10.00 S67'11'12 "W N 792736.42 C12 7.85 10.00 N67 "W 7.65 C13 E 758875.53 10.00 S67'48'48 "E N 792706.14 E 75 .717k,2 '792725.47 N 792726.15 E 758768.77 a E 758920.58 C3 f I n N 792698.76 tir E 7 58875.70 N 7927 .04 E 75874 .20 j t I N 792698.70 E 758864.70 N 7926 5.13: N 79266 .04 y N 792681.00 E 75*$721.26 E 75874 .06 N 792653.4 E 758974.71 N 792661.44 N 792661.56 E 758819.95 F E 758994.31 E 759017.08 C5 x ` N 792653.70 C2 N 792645.45 E 758864.94 N 79264 E 758768.50 E 758956:2 C8 N 792638.68 F I N 792644.41 N 792641.49 758964.17 n ` _ E 3.2 ;. I N 792653.51 N 792653.65 758973.75 Cl N 792643.45 E 758768.49 75$829.94 E 758854.94 Cl C 4 C10 N C2 C6 C7 s H. N._;792fi32: °92 �^ .., ., ..Na .. k.� _ _, ,. �... w:.__ _� _W� H M w_....HHH_, _ .........:.....::.....� w E 4 N E 758825.48 N 79262£3.68 lwlu *l HORIZONTAL CONTROL PLA SCALE: 1 "=20' COMPACTED I DRY DENSITY THE MARSHAL COMPACT TO 95% MAX DR1 DENSITY COMPACT TO MAX DRY DEN PER ASTM D1 NEW ASPHALT DETAIL 1 SCALE: NTS I C1.1 PHALT ANG HED ROCK RUN RIAL `1ii-*] / N 792629.94 E 759044.73 E 759050.12 20' 10' 0 20' SCALE = 1" = 20' 3 N 792631.73 ELEV. 4870.59 CURVE TABLE < LENGTH s CHORD- BEARING CHORD Cl 16.45 10.50 S44 "E 14.82 SS £ 30.63 19.50 N44'48'21 "W 27.58 C3 30.63 E 758825.48 N 79262£3.68 lwlu *l HORIZONTAL CONTROL PLA SCALE: 1 "=20' COMPACTED I DRY DENSITY THE MARSHAL COMPACT TO 95% MAX DR1 DENSITY COMPACT TO MAX DRY DEN PER ASTM D1 NEW ASPHALT DETAIL 1 SCALE: NTS I C1.1 PHALT ANG HED ROCK RUN RIAL `1ii-*] / N 792629.94 E 759044.73 E 759050.12 20' 10' 0 20' SCALE = 1" = 20' 3 N 792631.73 ELEV. 4870.59 CURVE TABLE CURVE LENGTH RADIUS CHORD- BEARING CHORD Cl 16.45 10.50 S44 "E 14.82 C2 30.63 19.50 N44'48'21 "W 27.58 C3 30.63 19.50 N45'1 1'39 "E 27.58 C4 16.40 10.50 S44'56'26 "W 14.78 C5 30.80 19.50 S45 "E 27.70 C6 3.13 2.00 S44 "W 2.82 C7 3.15 2.00 N45'09'24 "W 2.84 C8 43.35 27.50 N45'09'24 "W 39.00 C9 6.25 4.00 N44'47'38 "W 5.64 C10 7.85 10.00 N67'11'12 "E 7.65 C11 7.85 10.00 S67'11'12 "W 7.65 C12 7.85 10.00 N67 "W 7.65 C13 7.85 10.00 S67'48'48 "E 7.65 a 0 0 Y V V) O w Z Q 0 O z I- � V) CL Z U W V) O w w R Z V)o U V) It W? W00 to Z O r^ -' = o vJ Q F- V O(s O z� 0� Z O Z O U I - p ix w Z Z w CL O U �- 5 a �; s cl, z a; 4 O O V � O O N U o WARNING z LINE IS 2 INCHES w o w AT FULL SIZE z CON STRU TI ON NOTES 1. ALL DISTANCES AND DATA SHALL BE CHECKED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. IN CASE OF CONFLICT THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY SO THAT CLARIFICATION MAY BE MADE PRIOR TO THE START OF THE WORK. Y N 7928,'7 E 75-893 4 E 758935-31 UNDISTURBED NATIVE MATERIAL NOTE• 1. HOT PLANT CONCRETE ASPHALT PER ISPWC -2000 EDITION STANDARD DRAWING SD -801 z a; 4 a s+s L9 W O O V � O O N U o WARNING z LINE IS 2 INCHES w o w AT FULL SIZE z CON STRU TI ON NOTES 1. ALL DISTANCES AND DATA SHALL BE CHECKED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION. IN CASE OF CONFLICT THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY SO THAT CLARIFICATION MAY BE MADE PRIOR TO THE START OF THE WORK. Y N 7928,'7 E 75-893 4 E 758935-31 UNDISTURBED NATIVE MATERIAL NOTE• 1. HOT PLANT CONCRETE ASPHALT PER ISPWC -2000 EDITION STANDARD DRAWING SD -801 l� Kurt Hibbert Planning & Zoning Administrator City Of Rexburg 0 Included are three preliminary site plans for a proposed car wash at Approx. 750 2 East, Rexburg. I am hoping this can be presented at the May 4' meeting. Please let me know you have received it and which Thursday it will be. Thankyou, Tim Kaiser. Tim Kaiser 26433 Thacker Dr. Hemet, Ca. 92544 adpeddler44kyahoo.com 951.634 -4129 0 September 5 2006 Janell Hansen City Of Rexburg 19 E. Main St. Rexburg, Idaho 83440. RE: Car Wash Site Plan Permit Number: 06 00204 I believe I have addressed all the revisions requested from the initial site plan review except lighting. May I request to defer the shielded lighting submittal which will meet city and pollution standard's when the electrical engineer is engaged? I thank you for your time and look forward to moving ahead with this project. Best Wishes, -- 4 . Tim Kaiser 5434 Trade Wind Dr. Windsor, Co. 80528. 951.634 -4129 970.223 -6842