Loading...
HomeMy WebLinkAboutPLANS - 09-00379 - 68 S Center - TwizlberryI � II 1_ II FRONT VIEYi SIDE VIEW (AT O/L) Ar-GENT DISPLAY REGE55 TYPE A a AGGENT DISPLAY REGE55 DETAIL I , FRONT VIEW 51DE VIEW (AT G/L) AGGENT DISPLAY REGE55 TYPE B MOMMMIRRO W!, i } ! i w U U O w d' F w C7 � W (Y U G � � e U= - a �w W F a - W � ov a� - a 5OUTH ELEVATION oc✓.non o; cooes. n.y.sarvs snc sror�_ ;.a -ors QO. A5 5­ Twizlberry 0900379 u EAST ELEVATION s` E °°E`l to m .1 44zp. ti 4 } 3 � - � .w•* }� ƒ� # 9 � ƒ \ © «2i s» y; PA Al V :IO—, � � S I M I Levu -0" W Ref. Level I. FE 10ICATES PORTABLE FIRE EXTINGUISHERS, MINIMUM REQUIREMENTS: ZAIOBC. (5EE FLOOR PLAN) DOOR, DOOR GLAZING 4 HARDWARE NOTES: Q ALL DOOR HARDWARE TO MEET ADA REQUIREMENTS, Q MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLT5 ARE PROHIBITED ON DOORS. A5 ALL THRESHOLDS TO MEET ADA REQUIREMENTS - VERTICAL CHANGE IN LEVEL NOT TO EXCEED 1/4" OR BEVELED CHANGE IN LEVEL NOT TO EXCEED 1/2" WITH 1:2 SLOPE. Q DOORS WITH CL05ER AND LATCH TO HAVE 12" MINIMUM CLEAR FROM LATCH TO FIN15HED FACE OF PERPENDICULAR WALL ON PUSH 51D E. (NOT REQUIRED IF CLOSER 15 NOT USED) A DOORS TO HAVE IS" MINIMUM CLEAR FROM LATCH TO PERPENDICULAR WALL ON PULL S IDE, Q EXIT DOORS SHALL HAVE PANIC DEVICES . Ai DOORS NOTED "GLAZED" SHALL HAVE DOOR LITE GLAZED WITH 1/4" TEMPERED 57LA55. Q 5TORE FRONTS SHALL BE INSULATED LOW -E INSULATED GLAZED UNITS AITH BOTH PANES TEMPERED, TYPICAL FOR BOTH THE DOOR AND SIDELIGHTS. TOILE ROOM NOTES INSTALL HO5E BIB AND FLOOR DRAIN IN EACH TOILET ROOM 1. INSTALL SHEET VINYL OR CERAMIC TILE FLOORING IN EACH TOILET RM 2. WITH 6" COVED BASE AND NECESSARY COVED BASE ACCESSORIES, 4, INSTALL RFP OR CERAMIC TILE WAINSCOT 4' -0" HIGH BEHIND WATER CLOSET AND ADJACENT WALL. <15T1 OOR EX17 LIGHTED EXIT SIGN GA FILE No. WP 5 WALL TO EXTEND FROM FLOOR TO CEILING, ONE LAYER 5/8" TYPE 'X' GYP5UM BOARD APPLIED PARALLEL WITH OR AT RIGHT ANGLES TO EACH 51DE 5/8" TYPE 'X' GYPSUM BOARD OF 2x4 WOOD STUDS SPACED AT 24" o.c. W/ 6d COATED EACH SIDE NAILS 1 - 1 18" LONG, 0.0115" SHANK, 1/4" HEADS, 7" o.c. GYPSUM BOARD TO BE NAILED TO TOP 6 BOTTOM PLATES x AT 7" o.c., STAGGER JOINTS 24" ox— EACH SIDE. PROVIDE FIRE BLOCKING AT A MINIMUM OF 10 FEET VERTICAL 2x6 or 2x4 WOOD 5TUD5 AND AT INTERSECTING CEILINGS. AT 24" o.c. � MEN'S \ I WOMEN'S � 701 LET RM �' / T01 LET RM,\ 1 � I _ E F X m m 3' -5 3/4" 1 -'1 1/2" ^,I All 1 " -7 1/2" 51 All i 7' -0 1/4" N � NDN SUITE NO 5 - 2567 5f ( FLOOR AREA) ,-- NEW I -HOUR FIRE RATED WALL AGGr551 B 1 L. 1 7** ' 57ANDARD5 5Ox48 SPOUT 18° GRAB BAIL 42" TO NEAREST T2 OBSTRUCTION 5P OIT � 511 —01 15" MIN. — 47 GRAB BAR 3 1/2" MAX. MAX. 12 11 T 1 � 12 36" GRAB BAR PARALLEL APPROACH FORWARD APPROACH 77 m — fn j TO TOP OF SPOUT FLUSH HANDLE ON OPEN 510a— m DRINKING F OUNTA I N GRAB BARS INSULATE ALL WATER 5UPPLY 4 DRAIN F E z TOILET T155UE PIPING DISPENSER 30 "x48" ty X CLEAR \ < a z I FLOOR ` 0 v SPACE Ij) IN LAVATORY s OPTION 'A' MIRROR T4 TOILET T155UE DISPENSER TO REFLEOTIV SURFACE m TOI LET AGGE55OR1 E5 TOILET AGG550R'� SGDU1� l DESCRIPTION _ �lltix SERIES 812 GRAB BAR, 1 Q �2 m ) g WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD < STAINLESS STEEL. SERIES 812 GRAB BAR, 1 kb Q p T2 LL FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. a I GENERAL NOTES: 1/2" DIA. x 36 ", CONCEALED MOUNTING T3 WITH ANCHORING DEVICES, I. FE 10ICATES PORTABLE FIRE EXTINGUISHERS, MINIMUM REQUIREMENTS: ZAIOBC. (5EE FLOOR PLAN) DOOR, DOOR GLAZING 4 HARDWARE NOTES: Q ALL DOOR HARDWARE TO MEET ADA REQUIREMENTS, Q MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLT5 ARE PROHIBITED ON DOORS. A5 ALL THRESHOLDS TO MEET ADA REQUIREMENTS - VERTICAL CHANGE IN LEVEL NOT TO EXCEED 1/4" OR BEVELED CHANGE IN LEVEL NOT TO EXCEED 1/2" WITH 1:2 SLOPE. Q DOORS WITH CL05ER AND LATCH TO HAVE 12" MINIMUM CLEAR FROM LATCH TO FIN15HED FACE OF PERPENDICULAR WALL ON PUSH 51D E. (NOT REQUIRED IF CLOSER 15 NOT USED) A DOORS TO HAVE IS" MINIMUM CLEAR FROM LATCH TO PERPENDICULAR WALL ON PULL S IDE, Q EXIT DOORS SHALL HAVE PANIC DEVICES . Ai DOORS NOTED "GLAZED" SHALL HAVE DOOR LITE GLAZED WITH 1/4" TEMPERED 57LA55. Q 5TORE FRONTS SHALL BE INSULATED LOW -E INSULATED GLAZED UNITS AITH BOTH PANES TEMPERED, TYPICAL FOR BOTH THE DOOR AND SIDELIGHTS. TOILE ROOM NOTES INSTALL HO5E BIB AND FLOOR DRAIN IN EACH TOILET ROOM 1. INSTALL SHEET VINYL OR CERAMIC TILE FLOORING IN EACH TOILET RM 2. WITH 6" COVED BASE AND NECESSARY COVED BASE ACCESSORIES, 4, INSTALL RFP OR CERAMIC TILE WAINSCOT 4' -0" HIGH BEHIND WATER CLOSET AND ADJACENT WALL. <15T1 OOR EX17 LIGHTED EXIT SIGN GA FILE No. WP 5 WALL TO EXTEND FROM FLOOR TO CEILING, ONE LAYER 5/8" TYPE 'X' GYP5UM BOARD APPLIED PARALLEL WITH OR AT RIGHT ANGLES TO EACH 51DE 5/8" TYPE 'X' GYPSUM BOARD OF 2x4 WOOD STUDS SPACED AT 24" o.c. W/ 6d COATED EACH SIDE NAILS 1 - 1 18" LONG, 0.0115" SHANK, 1/4" HEADS, 7" o.c. GYPSUM BOARD TO BE NAILED TO TOP 6 BOTTOM PLATES x AT 7" o.c., STAGGER JOINTS 24" ox— EACH SIDE. PROVIDE FIRE BLOCKING AT A MINIMUM OF 10 FEET VERTICAL 2x6 or 2x4 WOOD 5TUD5 AND AT INTERSECTING CEILINGS. AT 24" o.c. � MEN'S \ I WOMEN'S � 701 LET RM �' / T01 LET RM,\ 1 � I _ E F X m m 3' -5 3/4" 1 -'1 1/2" ^,I All 1 " -7 1/2" 51 All i 7' -0 1/4" N � NDN SUITE NO 5 - 2567 5f ( FLOOR AREA) ,-- NEW I -HOUR FIRE RATED WALL AGGr551 B 1 L. 1 7** ' 57ANDARD5 5Ox48 SPOUT 18° GRAB BAIL 42" TO NEAREST T2 OBSTRUCTION 5P OIT � 511 —01 15" MIN. — 47 GRAB BAR 3 1/2" MAX. MAX. 12 11 T 1 � 12 36" GRAB BAR PARALLEL APPROACH FORWARD APPROACH 77 m — fn j TO TOP OF SPOUT FLUSH HANDLE ON OPEN 510a— m DRINKING F OUNTA I N GRAB BARS INSULATE ALL WATER 5UPPLY 4 DRAIN F E z TOILET T155UE PIPING DISPENSER 30 "x48" ty X CLEAR \ < a z I FLOOR ` 0 v SPACE Ij) IN LAVATORY s OPTION 'A' MIRROR T4 TOILET T155UE DISPENSER TO REFLEOTIV SURFACE m TOI LET AGGE55OR1 E5 NEW WALL CONSTRUCTION USE TREATED 2 "xb" PLATES IN CONTACT WITH MASONRY OR CONCRETE SURFACES, 2 "xb" STUDS AT 16" o.c. WITH CONTINUOUS TOP PLATE. CONNECT NEW INFIILL WALL TO WALL CONSTRUCTION ABOVE. ATTACH BOTTOM PLATE TO EXI5TIN6 CONCRETE WITH POWER ACTIVATED FASTENERS, OR DRILLED EPDXY FASTENED BOLTS. BOLTS SHALL BE PLACED AT 48" a,c. FASTEN STUDS TO THE MA50NRY WALL5 ON EACH 51DE OF THE INFILL AREA 51MILAR TO THE FLOOR ATTACHMENT. INSTALL 1/16" WALL SHEATHING (05B) TO ALL OF THE NEW EXTERIOR WOOD FRAMING AND ON THE EXI5TIN6 CONSTRUCTION ABOVE THE INFILL WALL AS REQUIRED PLACE BUILDING WRAP ON ALL EXTERIOR 5HEATHING PRIOR TO THE INSTALLATION OF THE EXTERIOR FIN15HE5 AS DESCRIBED ON SHEET A -2 BUILDING ELEVATIONS. INSTALL R -Iq INSULATION IN ALL EXTERIOR WOOD FRAMING. INTERIOR WALL FIN15H INSTALL 5/8" TYPE 'X' GYPSUM BOARD OVER 6 MIL VAPOR BARRIER OVER THE IN51DE INFILL WALL. TAPED, TEXTURED AND PAINT GYPSUM BOARD WALL AS DIRECTED BY BUILDING OWNER. FIRE BLOCKING 15 REQUIRED AT 10,- oz. VERTICALLY AND AT THE TOP OF THE WALL- CEILING CONNECTION. i LIGHTED EXIT 51GN5 —\ LIGHTED EXIT 516N -7 11 EXI EXI I I i i I -- -- - -- - - -- -- -- - 1 NEW CANOPY OVERHANG 1 I TENANT I_�F O \/E NT FLOOR FLAN SUITE 5 /4" = 1 1 - 011 BUILDING AREA 5670 sF Q �i TOILET AGG550R'� SGDU1� l DESCRIPTION NEW WALL CONSTRUCTION USE TREATED 2 "xb" PLATES IN CONTACT WITH MASONRY OR CONCRETE SURFACES, 2 "xb" STUDS AT 16" o.c. WITH CONTINUOUS TOP PLATE. CONNECT NEW INFIILL WALL TO WALL CONSTRUCTION ABOVE. ATTACH BOTTOM PLATE TO EXI5TIN6 CONCRETE WITH POWER ACTIVATED FASTENERS, OR DRILLED EPDXY FASTENED BOLTS. BOLTS SHALL BE PLACED AT 48" a,c. FASTEN STUDS TO THE MA50NRY WALL5 ON EACH 51DE OF THE INFILL AREA 51MILAR TO THE FLOOR ATTACHMENT. INSTALL 1/16" WALL SHEATHING (05B) TO ALL OF THE NEW EXTERIOR WOOD FRAMING AND ON THE EXI5TIN6 CONSTRUCTION ABOVE THE INFILL WALL AS REQUIRED PLACE BUILDING WRAP ON ALL EXTERIOR 5HEATHING PRIOR TO THE INSTALLATION OF THE EXTERIOR FIN15HE5 AS DESCRIBED ON SHEET A -2 BUILDING ELEVATIONS. INSTALL R -Iq INSULATION IN ALL EXTERIOR WOOD FRAMING. INTERIOR WALL FIN15H INSTALL 5/8" TYPE 'X' GYPSUM BOARD OVER 6 MIL VAPOR BARRIER OVER THE IN51DE INFILL WALL. TAPED, TEXTURED AND PAINT GYPSUM BOARD WALL AS DIRECTED BY BUILDING OWNER. FIRE BLOCKING 15 REQUIRED AT 10,- oz. VERTICALLY AND AT THE TOP OF THE WALL- CEILING CONNECTION. i LIGHTED EXIT 51GN5 —\ LIGHTED EXIT 516N -7 11 EXI EXI I I i i I -- -- - -- - - -- -- -- - 1 NEW CANOPY OVERHANG 1 I TENANT I_�F O \/E NT FLOOR FLAN SUITE 5 /4" = 1 1 - 011 BUILDING AREA 5670 sF Q �i TOILET AGG550R'� SGDU1� MARK DESCRIPTION SERIES 812 GRAB BAR, 1 1/2" DIA. x 42 ", CONCEALED MOUNTING T1 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. SERIES 812 GRAB BAR, 1 1/2" DIA. x 18", CONCEALED MOUNTING T2 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. SERIES 812 GRAB BAR, 1 1/2" DIA. x 36 ", CONCEALED MOUNTING T3 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. MIRROR SERIES 780 18" x 36 ", MOUNT 38" ABOVE FLOOR T4 (TO REFLECTIVE SURFACE). MODEL NUMBERS ARE BASED ON WASHROOM ACCESSORIES AS MANUFACTURED BY BRADLEY CORP., WASHROOM ACCESSORIES. NEW WALL CONSTRUCTION USE TREATED 2 "xb" PLATES IN CONTACT WITH MASONRY OR CONCRETE SURFACES, 2 "xb" STUDS AT 16" o.c. WITH CONTINUOUS TOP PLATE. CONNECT NEW INFIILL WALL TO WALL CONSTRUCTION ABOVE. ATTACH BOTTOM PLATE TO EXI5TIN6 CONCRETE WITH POWER ACTIVATED FASTENERS, OR DRILLED EPDXY FASTENED BOLTS. BOLTS SHALL BE PLACED AT 48" a,c. FASTEN STUDS TO THE MA50NRY WALL5 ON EACH 51DE OF THE INFILL AREA 51MILAR TO THE FLOOR ATTACHMENT. INSTALL 1/16" WALL SHEATHING (05B) TO ALL OF THE NEW EXTERIOR WOOD FRAMING AND ON THE EXI5TIN6 CONSTRUCTION ABOVE THE INFILL WALL AS REQUIRED PLACE BUILDING WRAP ON ALL EXTERIOR 5HEATHING PRIOR TO THE INSTALLATION OF THE EXTERIOR FIN15HE5 AS DESCRIBED ON SHEET A -2 BUILDING ELEVATIONS. INSTALL R -Iq INSULATION IN ALL EXTERIOR WOOD FRAMING. INTERIOR WALL FIN15H INSTALL 5/8" TYPE 'X' GYPSUM BOARD OVER 6 MIL VAPOR BARRIER OVER THE IN51DE INFILL WALL. TAPED, TEXTURED AND PAINT GYPSUM BOARD WALL AS DIRECTED BY BUILDING OWNER. FIRE BLOCKING 15 REQUIRED AT 10,- oz. VERTICALLY AND AT THE TOP OF THE WALL- CEILING CONNECTION. i LIGHTED EXIT 51GN5 —\ LIGHTED EXIT 516N -7 11 EXI EXI I I i i I -- -- - -- - - -- -- -- - 1 NEW CANOPY OVERHANG 1 I TENANT I_�F O \/E NT FLOOR FLAN SUITE 5 /4" = 1 1 - 011 BUILDING AREA 5670 sF Q �i N3 -- U ACCF551 5IL17Y STANDARDS 42" TO NEARE5T OBSTRUCTION 36" GRAB 12" BAR T3 30x4& - -- SPOUT 3 1/2" MAX. PARALLEL APPROACH SPOUT I 15" MIN, ls :i5l' MAX. FORWARD APPROACH TO TOP OF SPOUT m DRINKING FOUNTAIN INSULATE ALL WATER SUPPLY $ DRAIN PIPING X 01 z z m,�N.IN ° I 50" x4ellf CLEAR I FLOOR SPACE L. - — .I LAVATORY TOILET AGGE550R1 E5 NEW WALL CONSTRUCTION USE TREATED 2 "x6" PLATES IN CONTACT WITH MASONRY OR CONCRETE SURFACES, 2 "x6" STUDS AT 16" o.G. WITH CONTINUOUS TOP PLATE, CONNECT NEW INFIILL WALL TO WALL CONSTRUCTION ABOVE. ATTACH BOTTOM PLATE TO EXISTING CONCRETE WITH POWER ACTIVATED FASTENERS, OR DRILLED EPDXY FASTENED BOLTS. BOLTS SHALL BE PLACED AT 48" o.G. FASTEN STUD5 TO THE MASONRY WALL5 ON EACH 51DE OF THE INFILL AREA SIMILAR TO THE FLOOR ATTACHMENT. INSTALL 1/16" WALL 5HEATHIN6 (05B) TO ALL OF THE NEW EXTERIOR WOOD FRAMING AND ON THE EXISTING CONSTRUCTION ABOVE THE INFILL WALL AS REQUIRED PLACE BUILDING WRAP ON ALL EXTERIOR 5HEATHIN6 PRIOR TO THE INSTALLATION OF THE EXTERIOR FINISHES AS DESCRIBED ON SHEET A -2 BUILDIN6 ELEVATIONS. INSTALL R - INSULATION IN ALL EXTERIOR WOOD FRAMING. INTERIOR WALL FINISH INSTALL 518" TYPE 'X' 6YP5UM BOARD OVER 6 MIL VAPOR BARRIER OVER THE IN51DE INFILL WALL, TAPED, TEXTURED AND PAINT GYPSUM BOARD WALL AS DIRECTED BY BUILDING OWNER. FIRE BLOCKING 15 REQUIRED AT 10, -0" ox— VERTICALLY AND AT THE TOP OF THE WALL- GEILIN6 CONNECTION. L16HTED EXIT 516N5 EXI EX I -- -- -- -- -- -- i NEW CANOPY OVERHANG TENAN IMPROVEMENT FLOOR PLAN SUITS 3 1/4 = I' -O ho kik ho � Q 0 LIGHTED EXIT 516N BUILDING AREA 560 sF Q T Q j i GENERAL NOTE5: 1. FE INDICATES PORTABLE FIRE EXTIN61.115HER5. MINIMUM REQUIREMENTS: 2AIOBC. (SEE FLOOR PLAN) EXISTI DOOR EXIT DOOR, DOOR GLAZING $ HARDWARE NOTES: Q ALL DOOR HARDWARE TO MEET ADA REQUIREMENTS, A MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH 5OLT5 ARE PROHIBITED ON DOORS. A5 ALL THRESHOLDS TO MEET ADA REQUIREMENTS - VERTICAL CHAN6E IN LEVEL NOT TO EXCEED 1/4" OR BEVELED CHAN6E IN LEVEL NOT TO EXCEED 1/2" WITH 1:2 SLOPE. Q DOORS WITH OL05ER AND LATCH TO HAVE 12" MINIMUM CLEAR FROM LATCH TO FIN15HED FACE OF PERPENDICULAR WALL ON PUSH SIDE. (NOT REQUIRED IF 01-05ER 15 NOT USED) A DOORS TO HAVE 16 MINIMUM CLEAR FROM LATCH TO PERPENDICULAR WALL ON PULL SIPS. A6 EXIT DOOR5 SHALL HAVE PANIC DEVICES. A DOORS NOTED "GLAZED" SHALL HAVE DOOR LITE GLAZED WITH 1/4" TEMPERED 6LA55, A STORE FRONTS SHALL BE INSULATED LOW -E INSULATED GLAZED UNITS WITH BOTH PANES TEMPERED, TYPICAL FOR BOTH THE DOOR AND SIDEL161-IT5. TOILET ROOM NOTES INSTALL H05E BIB AND FLOOR DRAIN IN EACH TOILET ROOM I. INSTALL SHEET VINYL OR CERAMIC, TILE FLOORING IN EACH TOILET RM 2. WITH 6" COVED BASE AND NECESSARY COVED BASE ACCESSORIES. 4. INSTALL RFP OR CERAMIC TILE WAIN5COT 4' -0" HIGH BEHIND WATER CLOSET AND ADJACENT WALL, LIGHTED EXIT SIGN --f T 6A FILE No. WP 3510 WALL TO EXTEND FROM FLOOR TO CEILING. ONE LAYER 5/6" TYPE 'X' GYPSUM BOARD APPLIED PARALLEL WITH OR AT RIGHT AN6LE5 TO EACH 51DE 5/8" TYPE 'X' GYPSUM BOARD OF 2x4 WOOD STUDS SPACED AT 24" ox.. W/ 6d COATED EACH 51 PE NAIL5 1 1/8" LONG, O.Og15" SHANK, 1/4" HEADS, T' o.G. GYPSUM BOARD TO BE NAILED TO TOP d BOTTOM PLATES AT 1" ox—, 5TA66ER JOINTS 24" ox— EACH SIDE. PROVIDE FIRE BLOCKING AT A MINIMUM OF 10 FEET VERTICAL 2x6 or 2x4 WOOD STUDS AND AT INTER5ECTIN6 CEILIN65. AT 24" O.G. \ TOILET ACGF550IR'lilro 50HE:DULF— MARK DESCRIPTION � MEN'S I WOMEN'S � SERIES 812 GRAB BAR, 1 1/2" DIA, x 42 ", CONCEALED MOUNTING T1 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. , , m SERIES 812 GRAB BAR, 1 1/2" DIA, x 18", CONCEALED MOUNTING T2 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. i SERIES 812 GRAB BAR, 1 1/2" DIA, x 36 ", CONCEALED MOUNTING T3 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD 3' -4" �. STAINLESS STEEL. MIRROR SERIES 780 18" x 36 ", MOUNT 38" ABOVE FLOOR T4 (TO REFLECTIVE SURFACE). MODEL NUMBERS ARE BASED ON WASHROOM ACCESSORIES AS < MANUFACTURED BY BRADLEY CORP., WASHROOM ACCESSORIES. NEW WALL CONSTRUCTION USE TREATED 2 "x6" PLATES IN CONTACT WITH MASONRY OR CONCRETE SURFACES, 2 "x6" STUDS AT 16" o.G. WITH CONTINUOUS TOP PLATE, CONNECT NEW INFIILL WALL TO WALL CONSTRUCTION ABOVE. ATTACH BOTTOM PLATE TO EXISTING CONCRETE WITH POWER ACTIVATED FASTENERS, OR DRILLED EPDXY FASTENED BOLTS. BOLTS SHALL BE PLACED AT 48" o.G. FASTEN STUD5 TO THE MASONRY WALL5 ON EACH 51DE OF THE INFILL AREA SIMILAR TO THE FLOOR ATTACHMENT. INSTALL 1/16" WALL 5HEATHIN6 (05B) TO ALL OF THE NEW EXTERIOR WOOD FRAMING AND ON THE EXISTING CONSTRUCTION ABOVE THE INFILL WALL AS REQUIRED PLACE BUILDING WRAP ON ALL EXTERIOR 5HEATHIN6 PRIOR TO THE INSTALLATION OF THE EXTERIOR FINISHES AS DESCRIBED ON SHEET A -2 BUILDIN6 ELEVATIONS. INSTALL R - INSULATION IN ALL EXTERIOR WOOD FRAMING. INTERIOR WALL FINISH INSTALL 518" TYPE 'X' 6YP5UM BOARD OVER 6 MIL VAPOR BARRIER OVER THE IN51DE INFILL WALL, TAPED, TEXTURED AND PAINT GYPSUM BOARD WALL AS DIRECTED BY BUILDING OWNER. FIRE BLOCKING 15 REQUIRED AT 10, -0" ox— VERTICALLY AND AT THE TOP OF THE WALL- GEILIN6 CONNECTION. L16HTED EXIT 516N5 EXI EX I -- -- -- -- -- -- i NEW CANOPY OVERHANG TENAN IMPROVEMENT FLOOR PLAN SUITS 3 1/4 = I' -O ho kik ho � Q 0 LIGHTED EXIT 516N BUILDING AREA 560 sF Q T Q j i GENERAL NOTE5: 1. FE INDICATES PORTABLE FIRE EXTIN61.115HER5. MINIMUM REQUIREMENTS: 2AIOBC. (SEE FLOOR PLAN) EXISTI DOOR EXIT DOOR, DOOR GLAZING $ HARDWARE NOTES: Q ALL DOOR HARDWARE TO MEET ADA REQUIREMENTS, A MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH 5OLT5 ARE PROHIBITED ON DOORS. A5 ALL THRESHOLDS TO MEET ADA REQUIREMENTS - VERTICAL CHAN6E IN LEVEL NOT TO EXCEED 1/4" OR BEVELED CHAN6E IN LEVEL NOT TO EXCEED 1/2" WITH 1:2 SLOPE. Q DOORS WITH OL05ER AND LATCH TO HAVE 12" MINIMUM CLEAR FROM LATCH TO FIN15HED FACE OF PERPENDICULAR WALL ON PUSH SIDE. (NOT REQUIRED IF 01-05ER 15 NOT USED) A DOORS TO HAVE 16 MINIMUM CLEAR FROM LATCH TO PERPENDICULAR WALL ON PULL SIPS. A6 EXIT DOOR5 SHALL HAVE PANIC DEVICES. A DOORS NOTED "GLAZED" SHALL HAVE DOOR LITE GLAZED WITH 1/4" TEMPERED 6LA55, A STORE FRONTS SHALL BE INSULATED LOW -E INSULATED GLAZED UNITS WITH BOTH PANES TEMPERED, TYPICAL FOR BOTH THE DOOR AND SIDEL161-IT5. TOILET ROOM NOTES INSTALL H05E BIB AND FLOOR DRAIN IN EACH TOILET ROOM I. INSTALL SHEET VINYL OR CERAMIC, TILE FLOORING IN EACH TOILET RM 2. WITH 6" COVED BASE AND NECESSARY COVED BASE ACCESSORIES. 4. INSTALL RFP OR CERAMIC TILE WAIN5COT 4' -0" HIGH BEHIND WATER CLOSET AND ADJACENT WALL, LIGHTED EXIT SIGN --f T 6A FILE No. WP 3510 WALL TO EXTEND FROM FLOOR TO CEILING. ONE LAYER 5/6" TYPE 'X' GYPSUM BOARD APPLIED PARALLEL WITH OR AT RIGHT AN6LE5 TO EACH 51DE 5/8" TYPE 'X' GYPSUM BOARD OF 2x4 WOOD STUDS SPACED AT 24" ox.. W/ 6d COATED EACH 51 PE NAIL5 1 1/8" LONG, O.Og15" SHANK, 1/4" HEADS, T' o.G. GYPSUM BOARD TO BE NAILED TO TOP d BOTTOM PLATES AT 1" ox—, 5TA66ER JOINTS 24" ox— EACH SIDE. PROVIDE FIRE BLOCKING AT A MINIMUM OF 10 FEET VERTICAL 2x6 or 2x4 WOOD STUDS AND AT INTER5ECTIN6 CEILIN65. AT 24" O.G. \ � MEN'S I WOMEN'S � TOILET RM �' / TOILET RM,\ I Q j i GENERAL NOTE5: 1. FE INDICATES PORTABLE FIRE EXTIN61.115HER5. MINIMUM REQUIREMENTS: 2AIOBC. (SEE FLOOR PLAN) EXISTI DOOR EXIT DOOR, DOOR GLAZING $ HARDWARE NOTES: Q ALL DOOR HARDWARE TO MEET ADA REQUIREMENTS, A MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH 5OLT5 ARE PROHIBITED ON DOORS. A5 ALL THRESHOLDS TO MEET ADA REQUIREMENTS - VERTICAL CHAN6E IN LEVEL NOT TO EXCEED 1/4" OR BEVELED CHAN6E IN LEVEL NOT TO EXCEED 1/2" WITH 1:2 SLOPE. Q DOORS WITH OL05ER AND LATCH TO HAVE 12" MINIMUM CLEAR FROM LATCH TO FIN15HED FACE OF PERPENDICULAR WALL ON PUSH SIDE. (NOT REQUIRED IF 01-05ER 15 NOT USED) A DOORS TO HAVE 16 MINIMUM CLEAR FROM LATCH TO PERPENDICULAR WALL ON PULL SIPS. A6 EXIT DOOR5 SHALL HAVE PANIC DEVICES. A DOORS NOTED "GLAZED" SHALL HAVE DOOR LITE GLAZED WITH 1/4" TEMPERED 6LA55, A STORE FRONTS SHALL BE INSULATED LOW -E INSULATED GLAZED UNITS WITH BOTH PANES TEMPERED, TYPICAL FOR BOTH THE DOOR AND SIDEL161-IT5. TOILET ROOM NOTES INSTALL H05E BIB AND FLOOR DRAIN IN EACH TOILET ROOM I. INSTALL SHEET VINYL OR CERAMIC, TILE FLOORING IN EACH TOILET RM 2. WITH 6" COVED BASE AND NECESSARY COVED BASE ACCESSORIES. 4. INSTALL RFP OR CERAMIC TILE WAIN5COT 4' -0" HIGH BEHIND WATER CLOSET AND ADJACENT WALL, LIGHTED EXIT SIGN --f T 6A FILE No. WP 3510 WALL TO EXTEND FROM FLOOR TO CEILING. ONE LAYER 5/6" TYPE 'X' GYPSUM BOARD APPLIED PARALLEL WITH OR AT RIGHT AN6LE5 TO EACH 51DE 5/8" TYPE 'X' GYPSUM BOARD OF 2x4 WOOD STUDS SPACED AT 24" ox.. W/ 6d COATED EACH 51 PE NAIL5 1 1/8" LONG, O.Og15" SHANK, 1/4" HEADS, T' o.G. GYPSUM BOARD TO BE NAILED TO TOP d BOTTOM PLATES AT 1" ox—, 5TA66ER JOINTS 24" ox— EACH SIDE. PROVIDE FIRE BLOCKING AT A MINIMUM OF 10 FEET VERTICAL 2x6 or 2x4 WOOD STUDS AND AT INTER5ECTIN6 CEILIN65. AT 24" O.G. \ � MEN'S I WOMEN'S � TOILET RM �' / TOILET RM,\ I � a , m a M I i 3'-5 3/4" (, 3' -4' 3' -4" �. 1' -0 1/4" NDN SUITE X10 2 ,5675f (15C FL NEW I -HOUR FIRE RATED WALL 18 " GRAB BAR ---\ Tz 4 GRAB BAR T1 f�f� m GENERAL NOTES: 1. FE INDICATES PORTABLE FIRE EXTINGUISHERS. MINIMUM REQUIREMENTS: 2AIO5C. (SEE FLOOR PLAN) DOOR, DOOR GLAZING $ HARDWARE NOTES: Q ALL DOOR HARDWARE TO MEET ADA REQUIREMENTS, A2 MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS ARE PROHIBITED ON DOORS. Q ALL THRESHOLDS TO MEET ADA REQUIREMENTS - VERTICAL CHANGE IN LEVEL NOT TO EXCEED 1/4" OR BEVELED CHANGE IN LEVEL NOT TO EXCEED 1/2" WITH 1:2 SLOPE. A DOORS WITH CL05ER AND LATCH TO HAVE 12" MINIMUM CLEAR FROM LATCH TO FINISHED FACE OF PERPENDICULAR WALL ON PUSH SIDE. (NOT REQUIRED IF CLOSER 15 NOT USED) A DOORS TO HAVE IS" MINIMUM CLEAR FROM LATCH TO PERPENDICULAR WALL ON FULL SIDE, Q EXIT DOORS SHALL HAVE PANIC DEVICES. A DOOR5 NOTED "GLAZED" SHALL HAVE DOOR L17E GLAZED WITH 1/4" TEMPERED 6LA55. Q STORE FRONTS SHALL BE INSULATED LOW -E INSULATED GLAZED UNITS WITH BOTH PANES TEMPERED, TYPICAL FOR BOTH THE DOOR AND SIDELIGHTS, TOILET ROOM NOTES INSTALL H05E BIB AND FLOOR DRAIN IN EACH TOILET ROOM I. INSTALL SHEET VINYL OR CERAMIC TILE FLOORING IN EACH TOILET RM 2. WITH 6" COVED BASE AND NECESSARY COVED BASE ACCESSORIES. 4. INSTALL RFP OR CERAMIC TILE WAINSCOT 4' -0" HIGH BEHIND WATER CLOSET AND ADJACENT WALL. ,4GGE551BILI7Y STANDARDS 16 GRAB BAR 42" TO NEARE57 TZ 01357RU071 ON 42" GRAB BAR u 12 12" T 1 iA 36" GRAB BAR 30x48 I 5PCl T 1 � - -J 3 1/2" MAX. PARALLEL APPROACH ii UT 48x3 I 15" MIN. - - - -� 5" MAX. FORWARD APPROACH TO TOP OF SPOUT m DRINKING FOUNTAIN INSULATE ALL WATER SUPPLY $ DRAIN PIPING X 0 �_ z m 0 N N 0 " CLEAR FLOOR I v SPACE L -- J LAVATORY TOILET AGGE550R I E5 TOI AOOF 50HEDULF: MARK DESCRIPTION SERIES 812 GRAB BAR, 1 1/2" DIA. x 42 ", CONCEALED MOUNTING T1 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. T2 SERIES 812 GRAB BAR, 1 1/2" DIA. x 18 CONCEALED MOUNTING WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL, SERIES 812 GRAB BAR, 1 1/2" DIA. x 36 ", CONCEALED MOUNTING T3 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. T4 MIRROR SERIES 780 18" x 36 ", MOUNT 38" ABOVE FLOOR (TO REFLECTIVE SURFACE). MODEL NUMBERS ARE BASED ON WASHROOM ACCESSORIES AS MANUFACTURED BY BRADLEY CORP., WASHROOM ACCESSORIES. <15T 005 EXI' LIGHTED EXIT SIGN ---� i r GA FILE No. WP 5510 WALL TO EXTEND FROM FLOOR TO CEILING. ONE LAYER 5/8" TYPE 'X' GYPSUM BOARD APPLIED PARALLEL WITH OR AT RIGHT ANGLES TO EACH 51DE 5/6" TYPE 'X' GYPSUM BOARD OF 2x4 WOOD 5TUD5 SPACED AT 24" oz. W/ 6d COATED EACH 51DE NAILS 1 7 /8" LONG, O.Ogl5" SHANK, 1/4" HEAD5, 7" oz. GYPSUM BOARD TO BE NAILED TO TOP d BOTTOM PLATES AT 7" o.c., 5TAG6ER JOINTS 24" o.c. EACH SIDE. it i PROVIDE FIRE BLOCKING AT A MINIMUM OF 10 FEET VERTICAL 2x(o or 2x4 WOOD 5TUD5 AND AT INTERSECTING CEILIN65. AT 24" ox, EXI MEN'S WOMEN'S TOILET RM \h ! TOILET RM.\ x '- , I � x m ❑ L II V -5 5/4" m N } 1 NDN 5U 1 TE NO 5 - 2867 5f (I G FLOOR AREA) 1 i -- NEW I -HOUR FIRE RATED WALL NEW WALL CONSTRUCTION USE TREATED 2 "xb" PLATE5 IN CONTACT WITH MASONRY OR CONCRETE SURFACES, 2 "xb" 5TUD5 AT 16" ox— WITH CONTINUOU5 TOP PLATE. CONNECT NEW INFIILL WALL TO WALL CONSTRUCTION ABOVE. ATTACH BOTTOM PLATE TO EXISTING CONCRETE WITH POWER ACTIVATED FASTENERS, OR DRILLED EPDXY FASTENED BOLTS. BOLTS SHALL BE PLACED AT 48" o.c. FASTEN STUDS TO THE MA50NRY WALL5 ON EACH 51DE OF THE INFILL AREA 51MILAR TO THE FLOOR ATTACHMENT. INSTALL 1/16" WALL SHEATHING (0515) TO ALL OF THE NEW EXTERIOR WOOD FRAMING AND ON THE EX15TIN6 CONSTRUCTION ABOVE THE INFILL WALL AS REQUIRED PLACE BUILDING WRAP ON ALL EXTERIOR SHEATHING PRIOR TO THE INSTALLATION OF THE EXTERIOR FINI5HE5 AS DESCRIBED ON SHEET A -2 BUILDING ELEVATIONS. INSTALL R - INSULATION IN ALL EXTERIOR WOOD FRAMING. INTERIOR WALL FINISH INSTALL 5/6" TYPE 'X' GYPSUM BOARD OVER 6 MIL VAPOR BARRIER OVER THE IN51DE INFILL WALL. TAPED, TEXTURED AND PAINT GYPSUM BOARD WALL A5 DIRECTED BY BUILDING OWNER. FIRE BLOCKING 15 REQUIRED AT 10,-0" o.c. VERTICALLY AND AT THE TOP OF THE WALL - CEILING CONNECTION. LIGHTED EXIT 516N5 —\ LIGHTED EXIT SIGN 4Q'- i 3' -4" Ai EXI i I T e v 6� U I i I I NEW CANOPY OVERHANG TENANT IMPRO FL OOR PLAN SUITS 3 I /4 = 1' -0" BUILDING AREA 5670 sf �o GENERAL NOTES: 1. FE INDICATES PORTABLE FIRE EXTINGUISHERS. MINIMUM REQUIREMENTS: 2AIO5C. (SEE FLOOR PLAN) DOOR, DOOR GLAZING $ HARDWARE NOTES: Q ALL DOOR HARDWARE TO MEET ADA REQUIREMENTS, A2 MANUALLY OPERATED EDGE OR SURFACE MOUNTED FLUSH BOLTS ARE PROHIBITED ON DOORS. Q ALL THRESHOLDS TO MEET ADA REQUIREMENTS - VERTICAL CHANGE IN LEVEL NOT TO EXCEED 1/4" OR BEVELED CHANGE IN LEVEL NOT TO EXCEED 1/2" WITH 1:2 SLOPE. A DOORS WITH CL05ER AND LATCH TO HAVE 12" MINIMUM CLEAR FROM LATCH TO FINISHED FACE OF PERPENDICULAR WALL ON PUSH SIDE. (NOT REQUIRED IF CLOSER 15 NOT USED) A DOORS TO HAVE IS" MINIMUM CLEAR FROM LATCH TO PERPENDICULAR WALL ON FULL SIDE, Q EXIT DOORS SHALL HAVE PANIC DEVICES. A DOOR5 NOTED "GLAZED" SHALL HAVE DOOR L17E GLAZED WITH 1/4" TEMPERED 6LA55. Q STORE FRONTS SHALL BE INSULATED LOW -E INSULATED GLAZED UNITS WITH BOTH PANES TEMPERED, TYPICAL FOR BOTH THE DOOR AND SIDELIGHTS, TOILET ROOM NOTES INSTALL H05E BIB AND FLOOR DRAIN IN EACH TOILET ROOM I. INSTALL SHEET VINYL OR CERAMIC TILE FLOORING IN EACH TOILET RM 2. WITH 6" COVED BASE AND NECESSARY COVED BASE ACCESSORIES. 4. INSTALL RFP OR CERAMIC TILE WAINSCOT 4' -0" HIGH BEHIND WATER CLOSET AND ADJACENT WALL. ,4GGE551BILI7Y STANDARDS 16 GRAB BAR 42" TO NEARE57 TZ 01357RU071 ON 42" GRAB BAR u 12 12" T 1 iA 36" GRAB BAR 30x48 I 5PCl T 1 � - -J 3 1/2" MAX. PARALLEL APPROACH ii UT 48x3 I 15" MIN. - - - -� 5" MAX. FORWARD APPROACH TO TOP OF SPOUT m DRINKING FOUNTAIN INSULATE ALL WATER SUPPLY $ DRAIN PIPING X 0 �_ z m 0 N N 0 " CLEAR FLOOR I v SPACE L -- J LAVATORY TOILET AGGE550R I E5 TOI AOOF 50HEDULF: MARK DESCRIPTION SERIES 812 GRAB BAR, 1 1/2" DIA. x 42 ", CONCEALED MOUNTING T1 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. T2 SERIES 812 GRAB BAR, 1 1/2" DIA. x 18 CONCEALED MOUNTING WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL, SERIES 812 GRAB BAR, 1 1/2" DIA. x 36 ", CONCEALED MOUNTING T3 WITH ANCHORING DEVICES, FINISH TO BE MANUFACTURER'S STANDARD STAINLESS STEEL. T4 MIRROR SERIES 780 18" x 36 ", MOUNT 38" ABOVE FLOOR (TO REFLECTIVE SURFACE). MODEL NUMBERS ARE BASED ON WASHROOM ACCESSORIES AS MANUFACTURED BY BRADLEY CORP., WASHROOM ACCESSORIES. <15T 005 EXI' LIGHTED EXIT SIGN ---� i r GA FILE No. WP 5510 WALL TO EXTEND FROM FLOOR TO CEILING. ONE LAYER 5/8" TYPE 'X' GYPSUM BOARD APPLIED PARALLEL WITH OR AT RIGHT ANGLES TO EACH 51DE 5/6" TYPE 'X' GYPSUM BOARD OF 2x4 WOOD 5TUD5 SPACED AT 24" oz. W/ 6d COATED EACH 51DE NAILS 1 7 /8" LONG, O.Ogl5" SHANK, 1/4" HEAD5, 7" oz. GYPSUM BOARD TO BE NAILED TO TOP d BOTTOM PLATES AT 7" o.c., 5TAG6ER JOINTS 24" o.c. EACH SIDE. it i PROVIDE FIRE BLOCKING AT A MINIMUM OF 10 FEET VERTICAL 2x(o or 2x4 WOOD 5TUD5 AND AT INTERSECTING CEILIN65. AT 24" ox, EXI MEN'S WOMEN'S TOILET RM \h ! TOILET RM.\ x '- , I � x m ❑ L II V -5 5/4" m N } 1 NDN 5U 1 TE NO 5 - 2867 5f (I G FLOOR AREA) 1 i -- NEW I -HOUR FIRE RATED WALL NEW WALL CONSTRUCTION USE TREATED 2 "xb" PLATE5 IN CONTACT WITH MASONRY OR CONCRETE SURFACES, 2 "xb" 5TUD5 AT 16" ox— WITH CONTINUOU5 TOP PLATE. CONNECT NEW INFIILL WALL TO WALL CONSTRUCTION ABOVE. ATTACH BOTTOM PLATE TO EXISTING CONCRETE WITH POWER ACTIVATED FASTENERS, OR DRILLED EPDXY FASTENED BOLTS. BOLTS SHALL BE PLACED AT 48" o.c. FASTEN STUDS TO THE MA50NRY WALL5 ON EACH 51DE OF THE INFILL AREA 51MILAR TO THE FLOOR ATTACHMENT. INSTALL 1/16" WALL SHEATHING (0515) TO ALL OF THE NEW EXTERIOR WOOD FRAMING AND ON THE EX15TIN6 CONSTRUCTION ABOVE THE INFILL WALL AS REQUIRED PLACE BUILDING WRAP ON ALL EXTERIOR SHEATHING PRIOR TO THE INSTALLATION OF THE EXTERIOR FINI5HE5 AS DESCRIBED ON SHEET A -2 BUILDING ELEVATIONS. INSTALL R - INSULATION IN ALL EXTERIOR WOOD FRAMING. INTERIOR WALL FINISH INSTALL 5/6" TYPE 'X' GYPSUM BOARD OVER 6 MIL VAPOR BARRIER OVER THE IN51DE INFILL WALL. TAPED, TEXTURED AND PAINT GYPSUM BOARD WALL A5 DIRECTED BY BUILDING OWNER. FIRE BLOCKING 15 REQUIRED AT 10,-0" o.c. VERTICALLY AND AT THE TOP OF THE WALL - CEILING CONNECTION. LIGHTED EXIT 516N5 —\ LIGHTED EXIT SIGN 4Q'- i 3' -4" Ai EXI i I T e v 6� U I i I I NEW CANOPY OVERHANG TENANT IMPRO FL OOR PLAN SUITS 3 I /4 = 1' -0" BUILDING AREA 5670 sf �o