Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PLANS - 09-00261 - Rent-A-Center - Remodel
CEILING NOTES: GENERAL NOTES: 1. EACH CEILING GRID HANGER WIRE TO BE ONE CONTINUOUS WIRE. NO SPLICING OF CONTRACTOR TO VERIFY SCOPE OF PROJECT WIRES WILL BE ACCEPTED. 1. WITH RENT -A- CENTER OPERATIONS. THESE PLANS ARE INTENDED TO REPRESENT R.A.C. DESIGN 2. MINIMUM SPACING ON CEILING GRID HANGER WIRES TO BE 4' -0" IN BOTH DIRECTIONS. INTENT. EXISTING CONDITIONS TO PREVAIL (IF- EQUIVALENT) AND SHALL BE VERIFIED IN THE FIELD BY R.A.C. OPERATIONS 3. WALL MOULDING TO BE USED ON ALL WALLS, NOT JUST PERIMETER WALLS. THESE PLANS ARE INTENDED TO BE CONSTRUCTION PERMIT DOCUMENTS USED FOR LOCAL PERMIT REQUIREMENTS. INFORMATION CONTAINED WITHIN ROOM CONSTRUCTION SCHEDULE OR SCOPE AS PROVIDED BY R.A.C. OPERATIONS IS TO SUPERSEDE CONDITIONS INDICATED IN THESE SPECIFICATIONS. THE SCOPE OF WORK AND SPECIFICATIONS OF WORK ARE SUBJECT TO 4. 5. CONTRACTOR TO PROVIDE A MINIMUM OF ONE (1) CASE/ PACKAGE OF CEILING TILES FROM SAME LOT NUMBER FOR FUTURE TILE REPLACEMENT. TILE TO BE PLACED, FULLY WRAPPED, IN BACKROOM AND LOCATION IDENTIFIED TO STORE MANAGER. INSTALL R -19 BATT INSULATION ABOVE SUSPENDED ACOUSTIC TILE CEILING THROUGHOUT. Rent A CHANGE AT THE DISCRETION OF OWNER/ TENANT. ELECTRICAL NOTES: 2. THE LANDLORD AND /OR GENERAL CONTRACTOR IS RESPONSIBLE FOR PERFORMING THE REQUIRED CONSTRUCTION FOLLOWING ALL NATIONAL, STATE, & LOCAL CODES AND FOR OBTAINING A 1. ALL ELECTRICAL WORK SHALL COMPLY WITH THE MOST CURRENT NATIONAL ELECTRICAL CODES (NFPA #70) WITH LOCAL AND STATE AMENDMENTS. FINAL INSPECTION APPROVED BY THE BUILDING DEPARTMENT, AND 2. ALL EMPTY CONDUIT TO BE SUPPLIED WITH A NYLON PULL WIRE. OBTAINING THE CERTIFICATE OF OCCUPANCY. RENT -A- CENTER IS NOT RESPONSIBLE FOR CODE VIOLATIONS PERFORMED BY THE LAND 3. ALL FLEX CONDUIT SHALL HAVE " T ITE- BITE" CONNECTORS. 3. LORD OR THE GENERAL CONTRACTOR. RENT -A- CENTER WILL COMPLETE A FINAL WALK -THRU INSPECTION OF IMPROVEMENTS AND WILL PROVIDE A WRITTEN PUNCH LIST TO THE GENERAL CONTRACTOR PRIOR TO FINAL 4. ELECTRICAL CONTRACTOR TO INSTALL AND WIRE OUTLETS IN FIXTURES WHERE SHOWN ON DRAWINGS - OUTLETS TO BE INSTALLED IN FIXTURES AFTER FIXTURE INSTALLATION. VERIFY EXACT LOCATION WITH FIXTURE CONTRACTOR. ACCEPTANCE. IN THE EVENT PUNCH LIST ITEMS ARE NOT 5. ALL DEDICATED CIRCUITS SHALL BE LABELED AS SUCH AT OUTLET. ALL DEDICATED COMPLETED IN 7 DAYS RENT -A- CENTER WILL COMPLETE THE OUTLETS AT TRANSACTION COUNTER SHALL BE LABELED "COMPUTER ONLY ". ITEMS AND DEDUCT THE COST FROM THE PAYMENT OWED LAND DEDICATED CIRCUITS SHALL BE AN ORANGE RECEPTACLE, HUBBLE #1G5362 LORD OR GENERAL CONTRACTOR. OR EQUAL. 4. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR RECEIPT AND SUBSEQUENT PROTECTION OF ALL ITEMS WHICH ARE TO BE 6. ELECTRICAL CONTRACTOR SHALL SIZE PANEL BOXES. MAIN SERVICE TO BE MINIMUM FURNISHED BY R.A.C. AND ARE TO BE INSTALLED BY GENERAL 200 AMP 3 PHASE 4 WIRE. 5. CONTRACTGRS. C IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR IT TO VERIFY ITEMS RECEIVED AGAINST THE ITEMS INDICATED 7. CONTRACTOR TO LABEL ALL C.P.U., COAX, R.C.A. JACKS, AND SPEAKER CABLES AT BOTH ENDS. ON THE BILL OF LADING AND ON THE FREIGHT SHIPPING TICKET. ANY DISCREPANCIES (ITEMS MISSING AND / OR DAMAGED) SHALL BE WRITTEN ON THE FREIGHT COMPANIES SHIPPING TICKET AND THE 8. ALL ELECTRICAL COVER PLATES ON CEILING TO BE WHITE, ALL ELECTRICAL COVER PLATES ON VERTICAL SURFACES SHALL BE WHITE IN COLOR. BILL OF LADING AND EACH DOCUMENT INITIALED BY THE GENERAL 9. ALL POWER POLES (AND POWER TO COLUMNS) SHALL HAVE SEPERATE CIRCUITS. CONTRACTOR. (WHEN CONTRACTOR IS ON SITE) 6. GENERAL CONTRACTOR TO PROVIDE TRASH RECEPTACLE DURING H. V.A.C. NOTES: CONSTRUCTION. 1. H.V.A.C. CONTRACTOR SHALL COORDINATE AND VERIFY HIS WORK SUCH THAT 2. 3. THE STRUCTURAL INTEGRITY OF THE BUILDING, INCLUDING ROOF, IS NOT LESSENED. IF THE CONTRACTOR IS TO FURNISH AND INSTALL COMPLETE H.V.A.C. SYSTEM, UNITS. THE H.V.A.C. SYSTEM SHALL CONFORM TO ALL LOCAL CODES. INSTALL PROPERLY SIZED ADJUSTABLE DIFFUSERS OVER TRANSACTION COUNTER, RESTROOM, STAGING ARIES, SALES FLOOR AND OFFICE. W4if � �. i n GENERAL NOTES 1. CONTRACTOR SHAL FILE ALL NECESSARY DRAWINGS AND SPECIFICATIONS WITH THE PROPER AUTHORITIES AND PAY FOR AND OBTAIN ALL PERMITS, CERTIFICATES OF APPROVAL, AND OTHER LEGAL NOTICES REQUIRED FOR THIS WORK. NO WORK SHALL COMMENCE UNTIL THE BUILDING PERMIT HAS BEEN OBTAINED. 4. 5. ALL SUPPLY AND RETURN AIR DUCTS TO BE 1" RIGID INSULATED MATERIAL. MAXIMUM LENGTH OF FLEX DUCT TO BE LIMITED TO 8' -0 ". RETURN AIR TO BE DIRECT DUCTED, NO CEILING PLENUM ALLOWED. H.V.A.C, FILTER TO BE IN RETURN AIR GRILL ACCESSIBLE FROM SALES FLOOR. ' ` 0 rd (� 2. "A.I.A. DOCUMENTS A101 & A201" RELATES TO THE WORK OF THIS PROJECT AND IS HEREBY MADE A PART OF THESE DRAWINGS AS THOUGH FULLY CONTAINED IN THESE DRAWINGS. 6. THERMOSTATS SHALL NOT BE LOCATED WHERE FIXTURE WALL UNITS ARE TO BE LOCATED, OR ON COLUMNS, OR CLOSE TO NIGHT LIGHTS. 3. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE LOCAL BUILDING CODE WITH LOCAL AMENDMENTS. ALL WORK SHALL BE IN ACCORDANCE WITH THE GOVERNING 7. ALL THERMOSTATS TO BE COORDINATED WITH AND APPROVED BY THE OWNER. VERIFY PROGRAMMING INSTRUCTIONS WITH OWNER. BUILDING CODE AND REGULATIONS OF LOCAL AUTHORITIES HAVING JURISDICTION. CONTRACTOR WILL BE RESPONSIBLE FOR THE APPROVAL OF ALL INSTALLED MATERIALS. 8. HEATING TO BE NATURAL GAS (IF AVAILABLE.) N0. SHEET NAME ISSUE DATE CONSTRUCT. REVISION SHOULD A DISCREPANCY OCCUR BETWEEN A SPECIFIED MATERIAL AND A CODE REQUIREMENT, THE GENERAL CONTRACTOR MUST NOTIFY THE OWNER g, INSTALL SMOKE DETECTORS IN RETURN AIR PER LOCAL CODE . THE FOLLOWING DEFINITIONS SHALL BE APPLIED TO THESE CONSTRUCTION DOCUMENTS. SPECIAL CARE SHALL BE TAKEN WHEN THESE TERMS ARE 4. PRIOR TO COMMENCEMENT OF WORK. ALL WORK SHALL COMPLY WITH THE 2006 LIFE SAFETY CODE (NFPA #101) AND LOCAL TELEPHONE AND DATA NOTES ENCOUNTERED. NOTIFY ARCHITECT OR PROJECT MANAGER IF CONFLICTING INFORMATION IS ENCOUNTERED. A - 0.0 TITLE SHEET 02/12/09 A -0.1 GENERAL NOTES SPECIFICATIONS 5. AND STATE FIRE CODES. GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE SITE AND SHALL NOTIFY THE "OWNER'S REPRESENTATIVE OF ANY DISCREPANCIES. 1. 2. INSTALL (1) RJ -31X TELEPHONE JACK ON TELEPHONE BACKBOARD FOR SECURITY SYSTEM. CONTRACTOR TO BE RESPONSIBLE TO SUPPLY AND INSTALL CONDUIT FOR TELEPHONE SERVICE FROM BACKBOARD TO EXTERIOR OF BUILDING. SIZE AND LANDLORD - BUILDING OWNER OWNER - RENT -A- CENTER TENANT - RENT -A- CENTER W A -0.2 GENERAL NOTES/ SPECIFICATION CONTINUED KEY PLAN A -1.1.1 CONSTRUCTION PLAN A -2 STAGING DETAIL/ SCHEDULE A -3 TRANSACTION COUNTER DETAILS 6. 7. 8. 9. RECHARGABLE PORTABLE FIRE EXTINGUISHERS SHALL BE PLACED IN ACCORDANCE WITH THE NFPA #10. CONTRACTOR SHALL CLEAN ENTIRE DEMISED PREMISES PRIOR TO TURNOVER TO TENANT, GUARANTEE: ALL WORKMANSHIP AND MATERIALS SHALL BE GUARANTEED FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE, UNLESS SPECIFIED OTHERWISE FOR A LONGER PERIOD OF TIME ON SPECIFIC ITEMS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING OR REPAIRING HIS OWN DEFECTIVE WORK, AS WELL AS PAY ALL COSTS INCIDENTAL THERETO, INCLUDING DAMAGE TO OTHER WORK, FURNISHINGS OR EQUIPMENT. DRAWINGS ARE NOT TO BE SCALED. ALL WORK SHALL BE LAID OUT BY DIMENSIONS. ANY VARIATION IN DIMENSIONS FROM THE APPROVED ARCHITECTURAL PLANS AND /OR STRUCTURAL AND MECHANICAL PLANS SHALL BE CALLED TO THE OWNER'S ATTENTION IMMEDIATELY. ALL DISCREPANCIES SHALL BE CORRECTED BEFORE CONTRACTOR PROCEEDS WITH HIS PORTION OF THE WORK. CONTRACTOR SHALL BE RESPONSIBLE FOR HIS RESPECTIVE PORTION OF THE WORK, AND WILL BE REQUIRED TO LOCATION OF CONDUIT SHALL CONFORM TO LOCAL TELEPHONE REQUIREMENTS. 3. CONTRACTOR SHALL INSTALL TELEPHONE AND DATA OUTLETS w/ CONDUIT (NOT EXPOSED) TO ABOVE CEILING HEIGHT FOR PHONE SYSTEM, SECURITY SYSTEM. ALL EMPTY CONDUIT TO BE SUPPLIED WITH A NYLON PULL WIRE. 4. RENT -A- CENTER'S VENDOR WILL SUPPLY AND INSTALL TELEPHONE SYSTEM. 5. RENT -A- CENTER'S SECURITY VENDOR WILL SUPPLY AND INSTALL SECURITY SYSTEM AND CONTROL PANEL. 6. VERIFY WITH RENT -A- CENTER OPERATIONS IF GENERAL CONTRACTOR IS TO INSTALL PHONE AND CAT 5 CABLES.. LIGHTING NOTES: CONTRACTOR - GEN. CONTRACTOR OR HIS FORCES UNDER CONTRACT TO OWNER. W U .--� W ( Z N ( O (n N ^ A -4 COLOR RAIL DETAIL A -5 RESTROOM MISC DETAILS A -6 WINDOW GRAPHIC ELEVATIONS MAKE ALL REQUIRED CORRECTIONS TO COMPLY WITH ALL DRAWINGS AT NO ADDITIONAL 1. FINAL LOCATION OF EMERGENCY LIGHTS AND EXIT LIGHTS SHALL BE O 0 CY COST TO OWNER. LOCATED PER CODE AND OR FIRE MARSHALL'S RECOMMENDATION. z z o rY 10. DRAWINGS ARE THE PROPERTY OF THE RENT -A- CENTER AND SHALL NOT BE COPIED OR DUPLICATED IN ANY MANNER. THEY SHALL BE USED WITH REFERENCE TO WORK UNDER CONSTRUCTION ONLY. MIS -USE OF THE LOAN OF THESE DRAWINGS SHALL OBLIGATE THE VIOLATOR FOR FULL FEE TO RENT -A- CENTER, AS STIPULATED IN THE A.I.A. SCHEDULE OF FEES. VARIATION OF THIS AGREEMENT SHALL BE PERMITTED ONLY BY A WRITTEN STATEMENT. O O 4_1 u� Z =) m 00 W __t cl� 1. MEASUREMENTS SHOWN ON THESE PLANS ARE TO BE USED FOR RENT -A- CENTER CONSTRUCTION PURPOSES ONLY. PR0J. NO, RAC,002 11. SAFETY DURING CONSTRUCTION: CONSTRUCTION SHALL BE PERFORMED IN SUCH A MANNER 2. CONTRACTOR TO INSTALL EMERGENCY LIGHTING & FIRE & SMOKE SYSTEMS PER ALL LOCAL & STATE CODES. DATE REVISED 12. AS TO PROTECT WORKMAN AND THE GENERAL PUBLIC FROM INJURY, AND THE ADJOINING PROPERTY FROM DAMAGE. STANDARD PRACTICES SHALL BE OBSERVED FOR FLASHING AND WATERPROOFING. 3 CONTRACTR TO THAT JOB PRICE WILL INCLUDE ALL PERMITS, LICENSES, TAP FEES, PLANS, (� 6/23/09 04/09/09 13. CONTRACTOR TO USE 6" WHITE HELVETICA LETTERS TO DESIGNATE ADDRESS. LETTERS TO BE MOUNTED ABOVE PRIMARY ENTRANCE AS REQUIRED BY CODE. 4. 5. CONTRACTOR TO VERIFY ANY STRUCTURAL COLUMNS WITHIN WALLS BEING DEMOLISHED. ON REMODELS - CONTRACTOR TO VERIFY REUSE OF ANY EXISTING DOORS. L� 6. CONTRACTOR TO INSTALL UP TO 200 SQ. YDS. OF CARPET IN STAGING AREA. 14. CONTRACTOR SHALL COORDINATE ALL NEW ROOF PENETRATIONS WITH THE LANDLORD VERIFY EXACT LOCATION WITH R.A.C. OPERATIONS. 15. CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING APPROPRIATE TEMPERATURE OF LEASE SPACE AFTER COMMENCEMENT OF WORK PER THE CONTRACT UNTIL SCOPE OF WORK IS COMPLETED AND ACCEPTED SO AS TO PROTECT WORK IN PLACE AND TO DRAWN BY PROVIDE A PROPER ENVIRONMENT FOR FUTURE WORK TO BE DONE AS SPECIFIED. 16. ALL POWER AND TELEPHONE LINES LEADING INTO STORE SHALL BE ENCLOSED M V B (PROTECTED) OR BURIED TO THE POINT WHERE THEY ENTER THE BUILDING TO PREVENT VANDALISM. SHEET NO. IN THE EVENT OF A CONFLICT IN THE CONTRACT DOCUMENTS THE CONTRACTOR SHALL PROVIDE THE GREATER VALUE OR QUANITY OF ITEMS. A -0.0 OUTLINE SPECIFICATIONS: CEILING GENERAL: A. CEILING TILE TO BE ARMSTRONG (CORTEGA #747 WHITE). 2x4 LAYIN TILES OR EQUAL. CEILING GRID TO BE ARMSTRONG (PRELUDE XL WHITE 15/16" EXPOSED TEE GRID SYSTEM). CEILING SHALL BE 10' -0" THROUGHT ENTIRE PREMISES. CEILING TO BE INSULATED w/ R -19 (min). FIBERGLASS INSULATION. UNLESS NOTED OTHERWISE. A. PROVIDE A SINGLE 200 AMP (MINIMUM), 3 PHASE, ELECTRICAL PANEL WITH SEPARATE ELECTRICAL METER. ELECTRICAL PANEL TO BE LOCATED IN CLOSE PROXIMITY TO THE REAR EXIT DOOR IN THE STAGING AREA. THE LOCATION OF THE PANEL SHALL BE APPROVED BY TENANT. THE PANEL SHALL BE INSTALLED PER CODE AND PROVIDED WITH ADEQUATE NUMBER AND SIZE OF CIRCUIT BREAKERS TO PROHIBIT OVERLOADING. NO CIRCUIT BREAKER SHALL BE LOADED TO MORE THAN 80 PERCENT OF THE BREAKER RATING. B. ALL FLUORESCENT LAMPS SHALL BE COOL WHITE, 800 SERIES, 32 WATT, T -8, 4100 KELVIN WITH A MINIMUM INITIAL LUMEN RATING OF 2950 AND 20,000 -HOUR LAMP LIFE RATING. A MAXIMUM OF NINE (9) 2' x 4' FOUR (4) TUBE FLUORESCENT LAY -IN FIXTURES PER CIRCUIT. C. EMERGENCY LIGHTING AND EXIT LIGHTS, AS REQUIRED BY CODE. (LED / BATTERY BACK -UP TYPE). D. ALL ELECTRICAL WIRING, VOICE / COMMUNICATION WIRING, AND COAXIAL CABLES SHALL BE INSTALLED IN CONDUIT, OR OTHER PROTECTIVE COVERING AS REQUIRED TO COMPLY WITH GOVERNING BUILDING CODES. PROVIDE TELEPHONE AND DATA OUTLETS w/ CONDUIT (NOT EXPOSED) TO ABOVE CEILING HEIGHT FOR PHONE SYSTEM, SECURITY SYSTEM. ALL EMPTY CONDUIT SHALL BE SUPPLIED WITH NYLON PULL WIRE. E. ONE (1) SWITCH IN EACH OFFICE AND RESTROOM. DISPLAY AREA AND STAGING AREA ON SEPARATE SWITCHES. PROVIDE SWITCHES PER PLAN. (UNLESS APPROVED BY RAC OPERATIONS). F. SEPARATE ELECTRICAL 20 AMP DEDICATED SERVICE TO ALL EXTERIOR FASCIA FOR SIGNAGE. G. PANEL(S) TO BE CLEARLY LABELED. H. PROVIDE DUPLEX RECEPTACLE ON SEPARATE CIRCUIT NEAR PANEL FOR TELEPHONE SYSTEM AND (1) DUPLEX RECEPTACLE FOR SECURITY SYSTEM. INSTALLATION, MATERIALS AND EQUIPMENT TO BE PROVIDED BY R.A.C. I. PROVIDE 20 AMP. J -BOX @ EXTERIOR FASCIA PER EACH SIGN LOCATION. J. PROVIDE TENANT SPACE w/ SEPARATE ELECTRICAL & GAS METER (AS APPLICABLE). DISPLAY AREA: A. 2' x 4', FOUR (4) LAMP, T -8/ ELECTRONIC BALLAST LAY -IN LIGHT FIXTURE WITH 0.125 CLEAR PRISMATIC LENSES. LIGHT FIXTURE RATIO OF ONE (1) FIXTURE PER 75 SQ. FT. THREE (3) OF THE 2' x 4' LIGHT FIXTURES TO BE WIRED DIRECTLY, UN- SWITCHED (24 HOUR LIGHTING), OF WHICH TWO (2) TO BE EQUALLY SPACED WITH -IN THE DISPLAY AREA, AND ONE (1) TO BE LOCATED DIRECTLY OVER THE TRANSACTION COUNTER. VERIFY LOCATION WITH TENANT. B. TRANSACTION COUNTER/ OUTLETS AT COUNTER WALL: ONE (1) 15 AMP DEDICATED DUPLEX RECEPTACLE, FOUR (4) ELECTRICAL BOXES/ OUTLETS FOR TELEPHONE JACKS/ LINES, COMPUTER LINE, AND FAX LINE. C. SIDE, FRONT AND REAR WALLS: ONE (1) DUPLEX PER 10 LINEAL FEET OF WALL. IN ADDITION ONE (1) 4" x 4" J -BOX w/ TWO (2) 20 AMP DEDICATED CIRCUITS AND ONE (1) DUPLEX J -BOX w/ ONE (1) 20 AMP DEDICATED CIRCUIT (FOR AVE- WALL). VERIFY LOCATION WITH TENANT NOTE: MAXIMUM OF FIVE (5) DUPLEXES PER CIRCUIT. OUTLETS TO BE WHITE IN COLOR. D. FOUR (4) 120v J -BOXES (w/ ELECTRICAL) ABOVE CEILING FOR POWER POLES ON SEPARATE DEDICATED CIRCUITS. VERIFY LOCATION WITH TENANT. PROVIDE COAXIAL CABLE FROM POWER POLE(S) TO AVE -WALL. VERIFY WITH RENT -A- CENTER'S FIELD OPERATOR THE NUMBER OF POWER POLE(S) TO BE CONNECTED TO AVE -WALL w/ COAXIAL CABLE. E. DISPLAY AREA - STORES IN WHICH EXISTING FIXTURES ARE TO BE USED: ONLY FIXTURES WITH FOUR (4) BULBS MAY BE REUSED. FIXTURES WITH MAGNETIC BALLAST & F40T12 LAMPS WILL BE ACCEPTABLE. VERIFY ALL COMPONENTS ARE OPERABLE AND IN GOOD WORKING CONDITION. RELOCATE FIXTURES SO THEY ARE ON 8'x10' SPACING. ALL FIXTURES SHALL BE RE- LAMPED HVAC (Heating, Ventilation and Air Conditioning System : 1. PROVIDE COMMERCIAL GRADE PER PACKAGE ROOF TOP UNITS, FACTORY ASSEMBLED AND PRE WIRED. CONSISTING OF CABINET, FRAME, SUPPLY FAN, HEAT EXCHANGER AND BURNER, CONTROL, AIR FILTER, REFRIGERANT COOLING COIL AND COMPRESSOR, CONDENSER COIL AND FANS AND CURBS FANS AND CURBS. ACCEPTABLE MANUFACTURERS ARE: CARRIER, TRANE, McQUAY AND YORK. NO SUBSTITUTIONS WITHOUT APPROVAL OF TENANT. 2. CABINET SHALL BE OF GALVANIZED STEEL WITH A BAKED ENAMEL FACTORY FINISH, WITH ACCESS PANELS, EASILY REMOVABLE SO THE ELECTRICAL, REFRIGERATION AND NATURAL GAS SERVICING CAN BE ACCOMPLISHED WITHOUT DISTURBING NATURAL AIRFLOW THROUGH THE UNIT. THE HEAT EXCHANGER, BEFORE COOLING SHALL BE ALUMINIZED STEEL, AND AFTER COOLING COIL SHALL BE STAINLESS STEEL. TWO STAGE HEATING WITH AUTOMATIC ELECTRIC RE- '!GNITION ON GAS MODELS AND 100% SAFETY SHUT -OFF. SUPPLY FAN SHALL BE CENTRIFUGAL TYPE RUBBER MOUNTED V -BELT DRIVE AND RUBBER ISOLATED HINGE MOUNTED MOTOR. PROVIDE 2" THICK GLASS FIBER FILTERS, DISPOSABLE MEDIA IN METAL FRAMES FOR EASY REPLACEMENT. PROVIDE A FORCED OR INDUCED DRAFT TYPE BURNER WITH ADJUSTABLE COMBUSTION AIR SUPPLY, PRESSURE REGULATOR, GAS VALVES, MANUAL SHUTOFF, INTERMITTENT SPARK OR GLOW COIL IGNITION, FLAME SENSING DEVICE. PROVIDE COPPER TUBE ALUMINUM FIN COIL ASSEMBLE WITH GALVANIZED DRAIN PAN. COMPRESSOR TO BE HERMETIC WITH3,60ORPM. MAXIMUM, WITH POSITIVE LUBRICATION, CRANK- CASE HEATER, HIGH AND LOW PRESSURE SAFETY CONTROLS, MOTOR OVERLOAD PROTECTION, SERVICE VALVES AND FILTER DRIER. TIME OFF CIRCUIT SHALL LIMIT NUMBER OF COMPRESSOR STARTS TO 12 PER HOUR. PROVIDE COPPER TUBE ALUMINUM FIN COIL CONDENSER, WITH DIRECT DRIVE AXIAL FANS, RESILIENTLY MOUNTED WITH FAN GUARD, MOTOR OVERLOAD PROTECTION, WIRED TO OPERATE WITH COMPRESSOR AND SHALL BE LIFETIME LUBRICATED. 3. UNIT SHALL BE COMPLETELY WIRED FOR BOTH HEATING AND COOLING, WHERE THE ENTIRE ELECTRICAL SYSTEM IS CONNECTED TO ONE TERMINAL JUNCTION BOX, TO RECEIVE ONE ELECTRICAL SERVICE. UNIT SHALL CONTAIN ITS OWN RELAYS AND TRANSFORMERS TO HAVE 24v SPACE THERMOSTAT CONTROL OF HEATING, COOLING AND VENTILATION. 4. CONTROLS WILL HAVE BRANCH CIRCUIT OVER CURRENT PROTECTION WITH FUSES OR BREAKERS, COMPRESSOR PROTECTION, COMPRESSOR MOTOR PROTECTION, HIGH -LOW PRESSURE SWITCH AND COMBINATION FAN LIMIT SWITCH. EACH MOTOR SHALL BE INDIVIDUALLY PROTECTED. PROVIDE EACH UNIT WITH FACTORY INSTALLED, MOLDED CASE DISCONNECT SWITCH WITH FUSE BLOCK INSIDE THE CONTROL CABINET. PROVIDE EACH UNIT WITH A FACTORY INSTALLED 13 amp RATED 115 volt CIRCUIT WITH GROUND FAULT INTERRUPTER ELECTRIC OUTLET MOUNTED IN THE CONTROL CABINET SO AS TO USE OUTLET WHILE: POWER IS OFF IN UNIT FOR SERVICE OF THE UNIT. 5. CURBS SHALL BE 14" MINIMUM HEIGHT, WATER TIGHT TO PROTECT DUCTWORK AND UTILITY SERVICE. CONDENSATE DRAIN SHALL BE TAPPED TO PREVENT THE LOSS OF SUPPLY AIR OR DRAIN PAN OVERFLOW AND RUN TO WITHIN 6" OF ROOF DRAIN OR GUTTERS. 6 • THERMOSTAT TO BE ELECTRONIC, WITH NIGHT SET BACK CONTROLS, ONE PER UNIT. 7. THE DESIGNED HEATING AND AIR CONDITIONING SYSTEM SHALL BE DESIGNED TO A MINIMUM OF ONE TON OF AC/ 350 sf. ft. OF GROSS LEASED DEMISING SPACE, INCLUDING ALL STORAGE, OFFICES, RESTROOMS AND SALES AREAS. SUPPLY AND RETURN DUCT TO BE INSULATED AND AIR SUPPLY AND RETURN REGISTERS SHALL BE PROPERLY SIZED AND DISTRIBUTED TO SERVE AIR - HANDLING UNIT ADEQUATELY AND SHALL BE ADEQUATELY SIZED TO DISTRIBUTED CONDITIONED THROUGHOUT THE LENGTH AND WIDTH OF THE ENTIRE LEASE PREMISES. ALL RETURN AIR REGISTERS SHALL BE DUCTED TO THE AIR - HANDLING UNIT. RETURN AIR PLENUMS ARE NOT PERMITTED. ci nnoc A. CONCRETE SLAB OR WOOD FLOOR TO BE STRUCTURALLY SOUND, LEVEL, SMOOTH, CLEAN, FREE OF ALL PREVIOUS FLOOR FINISHES AND READY FOR CARPET. CARPET TO BE INSTALLED PER MANUFACTURER'S INSTRUCTIONS: 1. INSTALL NEW GLUE DOWN CARPET AS INDICATED: DISPLAY AREA CARPET TYPE: GRAPHICS LOOP, SHAW PERFORMA BCF NYLON COLOR: STYLE #4N101 COLOR # B832G (w /ULTRALOC PATTERN BACKING) FOR ALL CARPET INSTALLATION QUESTIONS AND HELP CONTACT: SUE SHEPARD SHAW INDUSTRIES INC. P.O. DRAWER 2128 DALTON, GA. 30722 -2128 PH# 800 -720 -7429, PRESS 2, EXT. 7928 ADHESIVES STAGING AREA: A. ONE (1) 8' 2 -BULB T -8 / ELECTRONIC BALLAST SURFACE MOUNTED LIGHT FIXTURE OR 2' x 4' LAY -IN FIXTURES (SEE DISPLAY AREA SECTION FOR SPECIFICATION.) IN THE RATIO OF ONE (1) FIXTURE PER 150 SQ. FT. ONE FIXTURE TO BE WIRED DIRECTLY, UN- SWITCHED (24 HOUR LIGHTING). B. ONE (1) 110V DUPLEX OUTLET PER 20 LINEAL FEET OF WALL (MINIMUM). IN ADDITION, NEAR THE ELECTRICAL PANEL, ONE (1) DEDICATED 110V DUPLEX (FOR TELEPHONE SYSTEM), ONE (1) DEDICATED 110V DUPLEX (FOR SECURITY SYSTEM), ONE (1) 220V OUTLET FOR RANGE TESTING, AND ONE (1) 220V OUTLET FOR DRYER TESTING. SHAW INDUSTRIES ADHESIVE - SURESET 1000 (800 -- 424 -7429) SHAW INDUSTRIES SEAM SEALER - 4000 NOTE: APPROVED ALTERNATIVE ADHESIVES AND SEAM SEALERS ARE LISTED BELOW. SEAMS ARE TO BE ROW CUT / ROW CUT 1Z8" U NOTCH TROWEL WITH A 8 YARD PER GALLON SPREAD RATE ON ADHESIVE. DHESIVES SEAM `.SEALER OFFICE SPECIFICATIONS: 1 • TWO (2) OFFICE AREAS, MANAGERS OFFICE AT 9' x 9' (INSIDE DIMENSION), ONE (1) CUSTOMER ACCOUNT REPRESENTATIVE'S OFFICE AT 9' x 16'. A WINDOW AT 42 "(h) X 72 "(w) TO SHOWROOM. MANAGER OFFICETO HAVE EACH ONE (1) 42 "(h) X 36 "(w) WINDOW TO THE SHOWROOM. THE SHARED WALLS SEPERATING THE OFFICES SHALL HAVE ONE (1) 42 "(h) X 48 "(w) WINDOW BETWEEN EACH OFFICE. ALL WINDOWS TO HAVE WOOD TRIM AND SILL. OFFICE LOCATION TO BE DETERMINED BY TENANT. WALLS: A. ONE (1) SEPERATION WALL BETWEEN THE DISPLAY AND STAGING AREAS WITH ONE (1) 4' -0" x 6' -8" THERMOPLASTIC DOUBLE - ACTION SWINGING DOOR. ( SEE DOOR AND STOREFRONT SPECIFICATIONS). LOCATION OF WALL AND DOORWAY TO BE DETERMINED BY TENANT. B. ALL DEMISING AND PERIMETER WALLS MUST BE CONSTRUCTED TO THE DECK OF THE ROOF. ALL DEMISING AND PERIMETER WALLS SHALL CONSIST OF 2" x 4" METAL STUDS (MINIMUM 20 GAUGE). INTERIOR WALL SHALL CONSIST OF 2" x 4" METAL STUDS (MINIMUM 25 GAUGE). ALL STUDS ON 16" ON CENTER, COVER BOTH SIDES WITH SHEETROCK. ALL SHEETROCK SHALL BE TAPED, SPACKLED, SANDED SMOOTH AND PAINTED WITH A MINIMUM OF TWO (2) DRY COATS. (SEE FINISH SPECIFICATIONS). RESTROOM(S) SPECIFICATIONS A. RESTROOM(S) SHALL BE CONSTRUCTED PER SANCTIONED BUILDING CODES INCLUDING FEDERAL A.D.A. ACCESSIBILITY GUIDELINES. RESTROOM(S) TO INCLUDE AT MINIMUM, ONE LAVATORY, ONE TOILET, MIRROR, EXHAUST FAN, TOILET TISSUE DISPENSER, PAPER TOWEL DISPENSER, AND GRAB BARS. B. FLOOR FINISH SHALL BE 12" x 12" X 1/8" ARMSTRONG 51904 "STERLING" (INSTALLED PER MANUFACTURES RECOMMENDATIONS). LANDLORD TO INSTALL 2 (OR MORE) RESTROOMS IF REQUIRED BY ANY CODE, INCLUDING CODE BASED ON TENANTS BUSINESS USE. TRANSISTION STRIP REFRENCE 7/A3. FINISHES: 1 • WALLS OF DISPLAY AREA, OFFICES, RESTROOM & STAGING AREA TO BE PAINTED w/ MIN. TWO (2) DRY COATS SHERWIN - WILLIAMS SLEEK WHITE (SW1018) (SW1018) USING SHERWIN - WILLIAMS PROMAR 200 Eg -SHEL INTERIOR LATEX BASE. USE LATEX ON ALL DRYWALL SURFACES. NOTE G.C. TO LEAVE ONE GALLON OF PAINT USED ON WALLS FOR FUTURE USE. (TOUCH -UP) 2. ALL WOOD TRIM & METAL JAMBS TO BE PAINTED w/ MIN. TWO (2) DRY COATS SHERWIN- WILLIAMS STEEPLE GRAY (SW2131 @ 150 %) USING SHERWIN - WILLIAMS PROMAR 200 ALKYD EG -SHEL INTERIOR OIL BASE #B33W253 (PRIME AS RECOMMENDED BY MANUFACTURER). BOTH SIDES OF DOOR JAMB TO BE PAINTED TO MATCH TRIM. NOTE G.C. TO LEAVE ONE QUART OF PAINT USED ON WOOD TRIM FOR FUTURE USE. (TOUCH -UP) 3. ALL INTERIOR BIRCH/ OAK DOORS TO BE SANDED SMOOTH, FILLED AND FINISHED WITH (2) COATS CLEAR POLYURETHANE. 4. INSTALL COLOR RAIL (ACCENT STRIPES) (OWNER PROVIDED) AT SIDES AND REAR WALLS IN DISPLAY AREA PER THE DETAIL 1/ A -4 *(COLUMNS NOT TO BE WRAPPED WITH COLOR RAIL). 5. COLUMNS TO BE FURRED OUT TO THE SMALLEST DIMENSION POSSIBLE WITH SHEETROCK. EACH COLUMN TO HAVE TWO (2) DUPLEXES AND ONE COAXIAL TO BE PROVIDED Q 15" A.F.F. IN SHEETROCK. 6. OFFICE WINDOW(S): 1/4" CLEAR GLAZING WITH WOOD TRIM SILL, TOP OF WINDOW TO BE EVEN WITH TOP OF DOOR. ALL OFFICE WINDOWS (EXPOSED TO SHOWROOM) TO HAVE WINDOW BLINDS. -2 SLAT PLANTATION STYLE WHITE, SIMULATED WOOD. WINDOWS BETWEEN OFFICES SHALL HAVE NO BLINDS. BLINDS TO BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR. SPECIFICATION CONTINUATION ON SHEET A5. TENANT FIXTURES & EQUIPMENT ALL TENANT SUPPLIED FIXTURES & EQUIPMENT ARE TO BE INSTALLED BY G.C. AS PER PLAN LOCATION AND/ OR INSTRUCTED BY R.A.C. REPRESENTATIVE IN THE FIELD. TRANSACTION COUNTER GLASS DISPLAY CASE COMPUTER DISPLAY UNIT AUDIO /VISUAL /ELECTRONICS WALL (AVE WALL) CARPETED RISER COLOR RAIL CARPET AND CARPET BASE CARLSON DOOR/ FRAME (STAGING DOOR) POWER POLES WINDOW GRAPHICS (INTERIOR SIDE APPLICATION) EMPLOYMENT KIOSK DESK UNIT PHONE ALARM EXTERIOR STOREFRONT SIGN BRAND AND BENEFITS SIGNS GENERAL NOTES SUPPLIED BY TENANT INSTALLED BY GENERAL CONTRACTOR SUPPLIED AND INSTALLED BY RENT -A- CENTER'S VENDOR FOR CONSTRUCTION COORDINATION AT R.A.C. CONTACT LOCAL STORE OPERATIONS. � 1 J F . v � r� 4A4 a.v �;.� v • �r rfA N R. W W U� w Z u � � 171- TAYLOR 2055 2075 OFFICES: N HENRY 251 246 A. TWO (2) 2' x 4' 4 -TUBE LAY -IN FIXTURES (SEE DISPLAY AREA SECTION FOR SPECIFICATION) N PER OFFICE. PLEASE REFER TO ALL MANUFACTURERS SUGGESTED USE AND PRECAUTIONS. B. ONE (1) 110V DUPLEX OUTLET PER WALL. WHITE IN COLOR. PLEASE BE ADVISED, IF AN ADHESIVE / SEALER OTHER THAN SHAW INDUSTRIES RECOMMENDATION IS USED, AND IF ADHESIVE / SEAM SEALER FAILURE SHOULD OCCUR, C. TELEPHONE OUTLETS: ONE (1) TELEPHONE BOX/ OUTLET IN MANAGER'S OFFICE, IT WILL BE THE RESPONSIBILITY OF THE ADHESIVE MANUFACTURER TO RESPOND TO O FOUR (4) TELEPHONE BOX/ OUTLETS IN CUSTOMER ACCOUNT REPRESENTATIVE'S OFFICE. THAT FAILURE. CONDUIT (w/ PULL WIRE) SHALL BE INSTALLED FROM EACH TELEPHONE BOX/ OUTLET BACK TO 2. 6" CARPET BASE AT ALL WALLS OF DISPLAY AREA & OFFICES. CARPET & CARPET COVE THE PHONE PANEL BOARD IF REQUIRED BY LOCAL CODE. BUT AT A MINIMUM, CONDUIT (w/ PULL- BASE IS PROVIDED BY OWNER, INSTALLED BY GENERAL CONTRACTOR. WIRE) SHALL BE PROVIDED FROM EACH TELEPHONE BOX/ OUTLET AND BE STUBBED ABOVE CEILING. 3. VINYL COVE BASE (ROPPE 850 DARK GREY, 1/8") TO BE INSTALLED AT ALL WALLS OF RESTROOMS STAGING AREA AND RESTROOM (U.N.O. ON ROOM CONSTRUCTION SCHED.) to X NOTE GLUE VINYL BASE TO WALLS w/ VINYL ADHESIVE, (JOHNSONITE CTA 484 GREY). A. ONE (1) 100 WATT INCANDESCENT FIXTURE SPREAD ADHESIVE EVENLY ACROSS BACK OF VINYL_ BASE. B. ONE (1) GFCI DUPLEX OUTLET ABOVE LAVATORY. INSTALL CARPET TRANSITION STRIPS AT ALL AREAS WHERE CARPET ry PROJ, MEETS TILE OR EXPOSED CONCRETE. RAC.002 DATE 4. FLOOR FINISH IN THE RESTROOM(S) SHALL BE: 12" x 12" x 1/8" 6/23/09 ** U.N.O. = UNLESS NOTED OTHERWISE ** ARMSTRONG 51904 "STERLING". OFFICE SPECIFICATIONS: 1 • TWO (2) OFFICE AREAS, MANAGERS OFFICE AT 9' x 9' (INSIDE DIMENSION), ONE (1) CUSTOMER ACCOUNT REPRESENTATIVE'S OFFICE AT 9' x 16'. A WINDOW AT 42 "(h) X 72 "(w) TO SHOWROOM. MANAGER OFFICETO HAVE EACH ONE (1) 42 "(h) X 36 "(w) WINDOW TO THE SHOWROOM. THE SHARED WALLS SEPERATING THE OFFICES SHALL HAVE ONE (1) 42 "(h) X 48 "(w) WINDOW BETWEEN EACH OFFICE. ALL WINDOWS TO HAVE WOOD TRIM AND SILL. OFFICE LOCATION TO BE DETERMINED BY TENANT. WALLS: A. ONE (1) SEPERATION WALL BETWEEN THE DISPLAY AND STAGING AREAS WITH ONE (1) 4' -0" x 6' -8" THERMOPLASTIC DOUBLE - ACTION SWINGING DOOR. ( SEE DOOR AND STOREFRONT SPECIFICATIONS). LOCATION OF WALL AND DOORWAY TO BE DETERMINED BY TENANT. B. ALL DEMISING AND PERIMETER WALLS MUST BE CONSTRUCTED TO THE DECK OF THE ROOF. ALL DEMISING AND PERIMETER WALLS SHALL CONSIST OF 2" x 4" METAL STUDS (MINIMUM 20 GAUGE). INTERIOR WALL SHALL CONSIST OF 2" x 4" METAL STUDS (MINIMUM 25 GAUGE). ALL STUDS ON 16" ON CENTER, COVER BOTH SIDES WITH SHEETROCK. ALL SHEETROCK SHALL BE TAPED, SPACKLED, SANDED SMOOTH AND PAINTED WITH A MINIMUM OF TWO (2) DRY COATS. (SEE FINISH SPECIFICATIONS). RESTROOM(S) SPECIFICATIONS A. RESTROOM(S) SHALL BE CONSTRUCTED PER SANCTIONED BUILDING CODES INCLUDING FEDERAL A.D.A. ACCESSIBILITY GUIDELINES. RESTROOM(S) TO INCLUDE AT MINIMUM, ONE LAVATORY, ONE TOILET, MIRROR, EXHAUST FAN, TOILET TISSUE DISPENSER, PAPER TOWEL DISPENSER, AND GRAB BARS. B. FLOOR FINISH SHALL BE 12" x 12" X 1/8" ARMSTRONG 51904 "STERLING" (INSTALLED PER MANUFACTURES RECOMMENDATIONS). LANDLORD TO INSTALL 2 (OR MORE) RESTROOMS IF REQUIRED BY ANY CODE, INCLUDING CODE BASED ON TENANTS BUSINESS USE. TRANSISTION STRIP REFRENCE 7/A3. FINISHES: 1 • WALLS OF DISPLAY AREA, OFFICES, RESTROOM & STAGING AREA TO BE PAINTED w/ MIN. TWO (2) DRY COATS SHERWIN - WILLIAMS SLEEK WHITE (SW1018) (SW1018) USING SHERWIN - WILLIAMS PROMAR 200 Eg -SHEL INTERIOR LATEX BASE. USE LATEX ON ALL DRYWALL SURFACES. NOTE G.C. TO LEAVE ONE GALLON OF PAINT USED ON WALLS FOR FUTURE USE. (TOUCH -UP) 2. ALL WOOD TRIM & METAL JAMBS TO BE PAINTED w/ MIN. TWO (2) DRY COATS SHERWIN- WILLIAMS STEEPLE GRAY (SW2131 @ 150 %) USING SHERWIN - WILLIAMS PROMAR 200 ALKYD EG -SHEL INTERIOR OIL BASE #B33W253 (PRIME AS RECOMMENDED BY MANUFACTURER). BOTH SIDES OF DOOR JAMB TO BE PAINTED TO MATCH TRIM. NOTE G.C. TO LEAVE ONE QUART OF PAINT USED ON WOOD TRIM FOR FUTURE USE. (TOUCH -UP) 3. ALL INTERIOR BIRCH/ OAK DOORS TO BE SANDED SMOOTH, FILLED AND FINISHED WITH (2) COATS CLEAR POLYURETHANE. 4. INSTALL COLOR RAIL (ACCENT STRIPES) (OWNER PROVIDED) AT SIDES AND REAR WALLS IN DISPLAY AREA PER THE DETAIL 1/ A -4 *(COLUMNS NOT TO BE WRAPPED WITH COLOR RAIL). 5. COLUMNS TO BE FURRED OUT TO THE SMALLEST DIMENSION POSSIBLE WITH SHEETROCK. EACH COLUMN TO HAVE TWO (2) DUPLEXES AND ONE COAXIAL TO BE PROVIDED Q 15" A.F.F. IN SHEETROCK. 6. OFFICE WINDOW(S): 1/4" CLEAR GLAZING WITH WOOD TRIM SILL, TOP OF WINDOW TO BE EVEN WITH TOP OF DOOR. ALL OFFICE WINDOWS (EXPOSED TO SHOWROOM) TO HAVE WINDOW BLINDS. -2 SLAT PLANTATION STYLE WHITE, SIMULATED WOOD. WINDOWS BETWEEN OFFICES SHALL HAVE NO BLINDS. BLINDS TO BE SUPPLIED AND INSTALLED BY THE GENERAL CONTRACTOR. SPECIFICATION CONTINUATION ON SHEET A5. TENANT FIXTURES & EQUIPMENT ALL TENANT SUPPLIED FIXTURES & EQUIPMENT ARE TO BE INSTALLED BY G.C. AS PER PLAN LOCATION AND/ OR INSTRUCTED BY R.A.C. REPRESENTATIVE IN THE FIELD. TRANSACTION COUNTER GLASS DISPLAY CASE COMPUTER DISPLAY UNIT AUDIO /VISUAL /ELECTRONICS WALL (AVE WALL) CARPETED RISER COLOR RAIL CARPET AND CARPET BASE CARLSON DOOR/ FRAME (STAGING DOOR) POWER POLES WINDOW GRAPHICS (INTERIOR SIDE APPLICATION) EMPLOYMENT KIOSK DESK UNIT PHONE ALARM EXTERIOR STOREFRONT SIGN BRAND AND BENEFITS SIGNS GENERAL NOTES SUPPLIED BY TENANT INSTALLED BY GENERAL CONTRACTOR SUPPLIED AND INSTALLED BY RENT -A- CENTER'S VENDOR FOR CONSTRUCTION COORDINATION AT R.A.C. CONTACT LOCAL STORE OPERATIONS. � 1 J F . v � r� 4A4 a.v �;.� v • �r rfA N R. W W U� w Z u � � 1 04/09/091 DRAWN BY MVB SHEET N0. A -0.1 171- _ N N a 0 O n- 0 M O to X +-� 00 Li v) � ry PROJ, NO, RAC.002 DATE REVISED 6/23/09 1 04/09/091 DRAWN BY MVB SHEET N0. A -0.1 CONTINUED: CONSTRUCTION KEY DOORS C D_ MOP SINK. VERIFY REQUIREMENTS WITH at R -A -C OPERATIONS AND CITY CODE. 1. STOREFRONT TO BE COMMERCIAL GLASS DESIGN AND ANODIZED ALUMINUM FRAMES ENCOMPASSING A ALARM SYSTEM, ONE ADDITIONAL OUTLET C D — MINIMUM OF 80% OF THE WIDTH OF THE PREMISES (INCLUDING STOREFRONT DOORS). MINIMUM TO BE INSTALLED.( ALARM SYSTEM PROVIDED HEIGHT OF STORE FRONT GLASS TO BE NINE (9) FEET ABOVE FINISHED FLOOR. ALL GLAZING IN AND INSTALLED BY OTHERS). DOORS AND WINDOWS SHALL BE TEMPERED (SAFETY) GLASS. STEM WALLS (IF ANY) SHALL BE � ELECTRICAL PANEL. A MAXIMUM HEIGHT OF 18". � THERMOSTAT. 2. FRONT DOOR(S) TO BE OF COMMERCIAL GRADE TEMPERED GLASS, MINIMUM OF ONE (1) ADJOINING PAIR OF 3' - 0" x 7' - 0" DOORS, PROVIDING A SIX (6) FOOT WIDE CLEAR UNOBSTRUCTED OPENING, 5 ALARM PANEL 6' - 0" A.F.F. NEXT UNLESS APPROVED BY TENANT OTHERWISE. TO RJ - CONNECTION. ", 5A — ALARM KEY PAD 3. REAR DOOR IS TO BE 4' -0" x 7' -0 16 GAUGE, FULL FLUSH STEEL w/ STIFFENED - SEAMLESS EDGE, (TOP OF PAD CD 60" A.F.F.). w/ EITHER FIBERGLASS OR FOAM INFILL BETWEEN STIFFENERS. INSTALL PEEPHOLE AT 64" A.F.F. 6 RE: 1/A3 THE DOOR FRAME MUST BE 16 GAUGE, DOUBLE RABBET. JAMB ANCHORS ARE TO BE 18 GAUGE NEW TRANSACTION COUNTER (PROVIDED AND ARE TO BE USED TO SUPPORT THE FRAME TO THE ROUGH OPENING OF THE EXISTING WALL. CD _ BY OWNERS) RE: SHEET A -3 FRAMES CAN BE ORDERED KNOCKDOWN OR PRE - WELDED FOR FIELD INSTALLATION. EXIT DEVICE PER CODE. EMPLOYMENT KIOSK DESK C D_ 37" WIDE x 27 3/4" DEEP 4. ALL INTERIOR DOORS TO BE 3' - 0" x 6' - 8 ", SOLID - CORE, BIRCH OR OAK, 7 - PLY w/ MATCHING J BOX @ FASCIA PER EA. SIGN HARDWARE CD LOCATION (WITH 20 AMP CIRCUIT). ALL RESTROOM DOORS TO BE 3' -0" x 6' -8 ", SOLID -CORE, BIRCH OR OAK, 7 -PLY, w/ MATCHING VERIFY LOCATION & QUANTITY. HARDWARE. G D— CARLSON DOOR SEE RE: 1/A-2 5. DISPLAY/ STAGING DOOR (UNLESS OTHERWISE REQUIRING A FIRE -RATED DOOR PER CODE) TO BE POWER POLE LOCATION PROVIDED BY TENANT. ONE (1) 4' -0" x 6' -8" THERMOPLASTIC DOUBLE- ACTION SWINGING DOOR w/ 16 GAUGE HOLLOW C D- 120V J. BOX ABOVE CEILING TYPICAL AT METAL FRAME, AS SPECIFIED AND SUPPLIED BY CARLSON PRODUCTS INC. ® 1- 800 - 234 -1069 EACH POWER POLE. POWER POLES TO HAVE (IDENTIFY AS RENT -A- CENTER PROJECT). SEPERATE CIRCUITS. 1 24 HR. TIME CLOCK FOR SIGNAGE 6. ALL FACADES, FASCIA AND EXTERIOR PORTIONS OF BUILDING SHALL BE STRUCTURALLY SOUND, IN GOOD REPAIR, FREE OF SIGNAGE, AND SHALL HAVE ALL HOLES PATCHED AND PAINTED TO CD_ WATER FOUNTAIN (AS REQUIRED BY CODE) MATCH EXISITNG GD—DOOR BUZZER TO BE INSTALLED AT REAR DOOR AT 58" A.F.F. 7. SECURITY DEVICE TO BE HOOK ON SERIES SB -01 -(DOOR WIDTH) AS MANUFACTURED. BY: EXIT SECURITY INC. PROVIDE RAMP OR LANDING CD P.O. BOX 8276, FT. WORTH TX, 76124, CONTACT RALPH RODEN TO FINISH FLOOR AS REQUIRED. @ 1- 800 - 446 -6775. (IDENTIFY AS RENT -A- CENTER PROJECT). C ID — INSTALL EXTERIOR LIGHT ABOVE. REAR DOOR AS REQ'D. 8. SECURITY GATES (AS REQ'D BY TENANT. - SEE SCHEDULE OF WORK) TO BE 17 — DRYER & RANGE- OUTLETS BELOW ELECTRICAL ALUMATEK INC. "S - 17" MODEL (UNLESS OTHERWISE NOTED) AS MANUFACTURED PANEL (FOR TESTING PURPOSES ONLY). BY ALUMATEK. CONTACT ALUMATEK AT: 628 WILBUR CT., HAZLETON, PA 18201 PH. 1 866 - 287 - 1362 . - OR - "ECONOGUARD" GD— FOR TELEPHONE: SYSTEM (ONE DEDICATED OUTLET). ' g'F�1 METRO DOOR CO. MODEL (UNLESS OTHERWISE ;:r; AR -2418 ; NOTED) AS MANUFACTURED BY METRO DOOR OR APPROVED EQUAL. 1g RE: 6/A -5 CONTACT METRO DOOR AT: 32 E. BROAD ST., HAZELTON, PA 18102. =° PH 1 - 800 - 669 - 3667 RESTROOM CLG HT. AT 8'-0 VINYL TILE FLOORING. 20 RESTROOM TO 13E CONSTRUCTED PER ALL LOCAL, rq �3 STATE AND NATIONAL CODES AS REQUIRED. 21 OUTLETS AT 20' -0" O.C. TYP. IN STAGING. AREA. PLUMBING MOUNT AT 15" A.F.F. U.N.O. 1. INSTALL MIN. 18" X 24" WALL MOUNTED, SUPPORTED FIBERGLASS SERVICE SINK 22 - POSTER GRIPS LOCATION - RE: 5/A - 5 (IF SHOWN ON SHEET A1.1.1) - FLORESTONE MODEL FM OR EQUAL WITH HOT AND COLD WATER SERVICE FAUCET. HOT AND COLD WATER SERVICE TO FAUCET. FAUCET MUST BE THREADED FOR HOSE BIBB. SECURE SERVICE SINK TO WALL AS REQUIRED BY MANUFACTURER. 2. PROVIDE TANK TYPE WATER CLOSET AND WALL MTD. LAVATORY AT RESTROOMS. RESTROOM(S) TO MEET HANDICAPPED CODES AS REQUIRED. E S W 3. PROVIDE MIN. 5 GALLON WATER HEATER ABOVE CEILING AT EACH RESTROOM, (U.N.O.) 4. PROVIDE ONE(1) HANDICAP ACCESSIBLE WATER FOUNTAIN. (ONLY IF REQUIRED BY CODE). 110 V D NOTED © 15" AFF, UPLEX = 110 V DUPLEX ® 15" AFI -. G.F.1. UNLESS NOTED W/ COVER & GROUND FAULT INTERUPTER GENERAL MISCELLANEOUS = SINGLE POLE SWITCH (TOP 1. FIRE SPRINKLER DRAWINGS TO BE APPROVED FOR LEASE AREA IF AND ONLY IF REQUIRED @ 50" AFF.) v W z j BY CODE. REWORK EXISTING SPRINKLER IF NECESSARY. = TELEPHONE JACK @ 15" AFF. W/ COVER (( I `--' INSTALLATION AS REQ'D TO MEET RENT -A- CENTER FLOOR PLAN Qo AND FIRE CODES @-- = COMPUTER OUTLET @ 15" A.F.F. I\ 2. SPRINKLER SYSTEM, FIRE PROTECTION SYSTEM, AND FIRE ALRAM SYSTEM, AS REQUIRED BY CODE (D =THERMOSTAT 0-) N ( 0 = - POWER POLES _ — 3. CUSTOMER ENTRANCE TO PREMISES TO BE PROVIDED WITH ADEQUATE ACCESS AND MEET - 110 V QUADRUPLEX © 15" A.F.F. �-- ADA COMPLIANCE, AS REQUIRED BY CODE. w/ COVER (UNLESS NOTED) 0 (� 4. HELIUM TANK SUPPORTS TO BE PROVIDED AS CALLED FOR PER TENANT'S DESIGN OJ = JUNCTION Box z O CD L� z =5 AND SPECIFICATIONS. aD m W O � X 5. RECEIVING ENTRANCE, AS DESIGNATED BY TENANT, SHALL HAVE AN ADEQUATE LANDING PAD, -� = RJ -45 JACK TO THIN CLIENT IN MGR'S OFFICE „ -+-" pQ IW STEPS, ACCESSIBILITY,AND RAILINGS, ALL AS APPLICABLE, PER CODE. LANDLORD SHALL PROVIDE w/ COVER ® 15 A.F.F u� "t n ADEQUATE EGRESS AND (NEGRESS TO TENANT'S DESIGNATED RECEIVING ENTRANCES �- = 220 V RECEPTICAL - DRYER PROJ, N0. RAC.002 @ 36” A.F.F 6. PREMISES TO BE DELIVERED WITH NO BROKEN, CRACKED, OR CHIPPED GLASS. = 220 V RECEPTICAL - RANGE DATE REVISED 36" A.F.F 6/23/09 7. PREMISES TO BE DELIVERED IN BROOM CLEAN CONDITION, FREE OF DEBRIS, HAZARDOUS CIRCUIT BOTH 220 V RECEP. TOGETHER MATERIALS, AND ANY PRIOR TENANT'S FIXTURES, SIGNAGE AND WINDOW GRAPHICS. FOR APPLIANCE TESTING ONLY. 8. DELIVERED WITH BUILDING, ROOF, AND FOUNDATION STRUCTURALLY SOUND AND VOID OF ANY LEAKS EMERGENCY LIGHT FIXTURE OR WATER PENETRATIONS WITH BATTERY BACKUP = LIGHTED EXIT SIGN UTILITIES 0 = #RJ31 PHONE JACK FOR ALARM SYSTEM A. SEPERATE ELECTRIC GAS AND WATER METERS WITH EXCLUSIVE SERVICE LINES D DOOR BUZZER TO BE INSTALLED AT REAR EXTERIOR DOOR - 58" A.F.F. INSTALLED TO THE PREMISES. PROVIDE TELECOMMUNICATIONS CONDUIT AND A DRAWN BY PULL WIRE TO BUILDING AND THE PREMISES AS REQUIRED BY CODE OR OTHERWISE. 0 = TIME CLOCK MVB SHEET NO. A- 0.2 DUPLEX J-130X W/1 20A DEDICATED CONSTRUCTION PLAN SCALE: 1 /4 ))=i $—O)l U V V) uJ LIJ 0 0 0 0 X x < x x n- 0 0 LL1 - 0 N u� n � I I ' - c cn ( (n ( (f) v LLJ U n LLi 0 ( 3 - w 0� 0 00 00 U < Z ( ( h o o N N � � N N - ) 0 W 0 u n < < I 0 ry LL I-�- w w = L 0 � > o u 0 0 W U < � 0 < III < < r ry m < w w cn I < V) 11 , m C�6 < � u U V V) uJ LIJ o 0 0 < x x n- 111 0 0 n � I I ' - c cn ( (n ( (f) v v) n LLi 0 ( 3 - -:t 0 0� 0 00 00 U < < Z ( ( h o o N N � � N N - ) < LL I-�- w w = L 0 � � 0 < < � � r rr' III < < r ry m < w w cn I III r ry 1 11 , m C�6 < < z < I I I (-) < c < < >- < : cn U < < L n-' u Lij 7 7; 1 1 U U < c 0 0 — — 'j, 0 < 0 CL n n r ry n n 0 0 c cn W AR-2418 F T. CJ cn Q0 < F-- 0 CN 0 o ry (3 � z o� Q) m Ln x 0 00111 PROJ NO, RAC,002 DATE REVISED 6/23/09 DRAWN BY MVB SHEET NO. A-1.1.1 DRAWN BY MVB SHEET NO. A-1.1.1 TYPE 8, 4068 3/4' S ❑LID CORE, DBL ACTION(SWINGING) w/ 10'x10' PLEXI -GLASS WINDOW w/ 3' KICKPLATE (:J) CARLS 111' NOTE: ALL HARDWARE SHALL CONFORM TO ALL APPLICABLE STATE & ACCESSIBILITY CODES. (INCLUDING BUT NOT LIMITED TO MOUNTING HEIGHTS, OPERATING FORCE, & GRIP REQUIREMENTS,) DOOR FRAMES TO BE PAINTED EXTERIOR OF SERVICE DOOR & EMERGENCY EXIT PAINTED TO MATCH ADJACENT SURFACES, ALL INTERIOR DO ❑R FRAMES TO BE 16 G& KNOCK DOWN STYLE AS MANUFACTURED BY REPUBLIC BUILDERS OR TIMELY. ALL WOOD DOORS TO BE STAIN GRADE U.N,O, 7 -PLY BIRCH OR OAK DOORS BY WEYERHAEUSER OR EQUAL -ALL DOORS MUST BE THE SAME, NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE CONSTRUCTION BEGINS NOTE: MEASUREMENTS SHOWN ON THESE PLANS ARE TO BE USED FOR RENT -A -- CENTER CONSTRUCTION PURPOSES ONLY. al -n TYPE 1 1 PR. 3'- 0 "x7'- 0 "x1 -3/4" ALUM. FRAMED GLASS DOORS TYP. FRONT DOOR ALUMINUM FRAME LEAR TEMP. LASS FINISH: CLEAR POLY TYPE 2 3'-- 0 "x6' -8" SOLID CORE BIRCH OR OAK DOOR OFFICE DOORS METAL METAL METAL METAL 10" X 10" WINDOW, DOUBLE PANE PLEXI -GLASS 36" ABS KICKPLATE TYP E 3 4'- 0 "x6' -8" 3/4" SOLID CORE WOOD. DOOR w/ ABS SKIN w/ WINDOW. STAGING DOOR L LLUJLF�J: UUI - CNl/A /OUI, IUY JNfV10 IViUUIV i 3O NOTE CONTRACTOR MUST VERIFY WALL THICKNESS AND H -3 MANUF. FINISH w/ ABS SKIN w /ANSI CABO 117.A 4.13.8— HAGER 412S 2 SETS GASKETING & SILL SWEEP (BY S.F. MFG) ORDER APPROPRIATE FRAME 4 5/8' OR 4 7/8', PAINT TRIM COLOR TO BE GRAY H2 3A 4068 3/4' SOLID CORE BIRCH OR OAK w/ KICKPLATE 1 HOUR RATED H -3A CLEAR POLY (2) COATS LU I— 1 OFFICE — PASSAGE SET 4070 16 GA, SOLID -CORE METAL w/ STIFFENED - SEAMLESS EDGE, FIBERGLASS OR FOAM INFILL, FRAMES TO BE 16 ga, DOUBLED RABBET w/ 18 ga. ANCHORS FOR SUPPORT, H -4 MATCH ADJACENT SURFACES 1 WALL STOP: HAGAR 236W CONCAVE 32D H5 FRAMES :AN EITHER BE KNOCKDOWN O R PR - ASSEMBLED. ABOVE WALL) - REF. HEAD DETAIL H3 HAGAR BB1279, US26D 1 UNIVERSAL GRAVITY HINGE 3068 SOLID CORE BIRCH OR OAK 7-PLY -5 CLEAR POLY (2) COATS NOTE: O EXISTINC DOOR TO REMAIN LINE .............. (:J) CARLS 111' NOTE: ALL HARDWARE SHALL CONFORM TO ALL APPLICABLE STATE & ACCESSIBILITY CODES. (INCLUDING BUT NOT LIMITED TO MOUNTING HEIGHTS, OPERATING FORCE, & GRIP REQUIREMENTS,) DOOR FRAMES TO BE PAINTED EXTERIOR OF SERVICE DOOR & EMERGENCY EXIT PAINTED TO MATCH ADJACENT SURFACES, ALL INTERIOR DO ❑R FRAMES TO BE 16 G& KNOCK DOWN STYLE AS MANUFACTURED BY REPUBLIC BUILDERS OR TIMELY. ALL WOOD DOORS TO BE STAIN GRADE U.N,O, 7 -PLY BIRCH OR OAK DOORS BY WEYERHAEUSER OR EQUAL -ALL DOORS MUST BE THE SAME, NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE CONSTRUCTION BEGINS NOTE: MEASUREMENTS SHOWN ON THESE PLANS ARE TO BE USED FOR RENT -A -- CENTER CONSTRUCTION PURPOSES ONLY. al -n TYPE 1 1 PR. 3'- 0 "x7'- 0 "x1 -3/4" ALUM. FRAMED GLASS DOORS TYP. FRONT DOOR ALUMINUM FRAME LEAR TEMP. LASS FINISH: CLEAR POLY TYPE 2 3'-- 0 "x6' -8" SOLID CORE BIRCH OR OAK DOOR OFFICE DOORS METAL METAL METAL METAL 10" X 10" WINDOW, DOUBLE PANE PLEXI -GLASS 36" ABS KICKPLATE TYP E 3 4'- 0 "x6' -8" 3/4" SOLID CORE WOOD. DOOR w/ ABS SKIN w/ WINDOW. STAGING DOOR L LLUJLF�J: UUI - CNl/A /OUI, IUY JNfV10 IViUUIV i LLUJ ) N. tJVivvir, U ri � r,.�i�i r,L 1 THRESHOLD IN COMPLIANCE W/ ANSI CABO 1 THRESHOLD IN COMPLIANCE 117.A 4.13.8, HAGAR 404S w /ANSI CABO 117.A 4.13.8— HAGER 412S 2 SETS GASKETING & SILL SWEEP (BY S.F. MFG) PROVIDE STUD KICKERS PAINT TRIM 1 GASKET SET: HAGAR 873S —AL H2 AT TOP OF WALL AT HINGE 1 1 /2 PR. BUTTS: 4 1 /2x4 1 /2 1 PEEPHOLE AT 64" A.F.F. PB81, 26D HINGE BY PBB SIDE JAMB (PROVIDE ONE 1 OFFICE — PASSAGE SET 44 1/2" x 74 1/2" FALCON F101 D, 2 3/4" ASA 26D LEVER KICKER IN EACH DIRECTION 1 WALL STOP: HAGAR 236W CONCAVE 32D H5 (COLOR) BRUSHED ALUMINUM ABOVE WALL) - REF. HEAD DETAIL H3 HAGAR BB1279, US26D 1 UNIVERSAL GRAVITY HINGE DOTTED LINE INDICATES TOP 1 FLOOR SUPPORT HINGE PIN FALCON G102D -26D LEVER NOTE: PLATE /RUNNER OF STUD WALL CLG. LINE .............. NOTE: ABOVE 2 ITEMS ARE INCLUDED TO SHOWROOM FLOOR (TYPE A, B OR 50" ROUGH OPENING HAVE WINDOW BLINDS. (PLANTATION STYLE WHITE, SIMULATED WOOD). ALL EXTERIOR DOORS TO HAVE H3A (lHR FIRE RATED) BRUSH TYPE WEATHER STRIPPING z :D m APPLIED. 4; _Of' Ln (DISPLAY AREA SIDE) EQUAL HARDWARE SUBSTITUTIONS CLEAR DIM. BETWEEN FACE WILL BE ACCEPTABLE. 1 OFFICE PASSAGE SET DATE OF HOL. MTL. FRAME - FRAME TO BE REINFORCED w/ FLUSH BOLTS: HAGAR 283D -626 (TOP ONLY) - 12 GA. REINFORCING PLATES - 1 WALL STOP: HAGAR 236W CONCAVE 32D (IF REQUIRED) 6" LONG REINFORCING PLATES ` ARE TO BE WELDED TO INSIDE OF l FRAME ALONG THE HEAD AND JAMB, HEAD FROM THE CORNER OF THE FRAME GRAVITY HINGE 'o DOUBLE PANE PLEXI -GLASS 10" X 10" WINDOW ° Lo z w �pq Q . : w o o -3/4" SOLID CORE WD. o 00 0 DOOR w/ ABS SKIN 0 11OLL— ° o - 16 GA., KNOCK DOWN, HOL. 00 o � MTL. CASED OPENING (PRIMER COATED, READY TO PAINT) a Q - - 36" ABS KICKPLATE _ FRAME TO BE REINFORCED w/ w 12 GA. REINFORCING PLATE - u 6" LONG REINFORCING PLATE TO FLR, LIN I WELDED TO INSIDE OF FRAME, VERTICALLY, FROM THE BOTTOM OF FRAME STAGING ROOM DOOR EL EVATION (:J) CARLS 111' NOTE: ALL HARDWARE SHALL CONFORM TO ALL APPLICABLE STATE & ACCESSIBILITY CODES. (INCLUDING BUT NOT LIMITED TO MOUNTING HEIGHTS, OPERATING FORCE, & GRIP REQUIREMENTS,) DOOR FRAMES TO BE PAINTED EXTERIOR OF SERVICE DOOR & EMERGENCY EXIT PAINTED TO MATCH ADJACENT SURFACES, ALL INTERIOR DO ❑R FRAMES TO BE 16 G& KNOCK DOWN STYLE AS MANUFACTURED BY REPUBLIC BUILDERS OR TIMELY. ALL WOOD DOORS TO BE STAIN GRADE U.N,O, 7 -PLY BIRCH OR OAK DOORS BY WEYERHAEUSER OR EQUAL -ALL DOORS MUST BE THE SAME, NOTE: CONTRACTOR TO VERIFY ALL DIMENSIONS BEFORE CONSTRUCTION BEGINS NOTE: MEASUREMENTS SHOWN ON THESE PLANS ARE TO BE USED FOR RENT -A -- CENTER CONSTRUCTION PURPOSES ONLY. al -n TYPE 1 1 PR. 3'- 0 "x7'- 0 "x1 -3/4" ALUM. FRAMED GLASS DOORS TYP. FRONT DOOR ALUMINUM FRAME LEAR TEMP. LASS FINISH: CLEAR POLY TYPE 2 3'-- 0 "x6' -8" SOLID CORE BIRCH OR OAK DOOR OFFICE DOORS METAL METAL METAL METAL 10" X 10" WINDOW, DOUBLE PANE PLEXI -GLASS 36" ABS KICKPLATE TYP E 3 4'- 0 "x6' -8" 3/4" SOLID CORE WOOD. DOOR w/ ABS SKIN w/ WINDOW. STAGING DOOR L LLUJLF�J: UUI - CNl/A /OUI, IUY JNfV10 IViUUIV i LLUJ ) N. tJVivvir, U ri � r,.�i�i r,L 1 THRESHOLD IN COMPLIANCE W/ ANSI CABO 1 THRESHOLD IN COMPLIANCE 117.A 4.13.8, HAGAR 404S w /ANSI CABO 117.A 4.13.8— HAGER 412S 2 SETS GASKETING & SILL SWEEP (BY S.F. MFG) 44 1/2" x 38 1/2" PAINT TRIM 1 GASKET SET: HAGAR 873S —AL H2 1 SILL SWEEP: HAGAR 750S —AL 1 1 /2 PR. BUTTS: 4 1 /2x4 1 /2 1 PEEPHOLE AT 64" A.F.F. PB81, 26D HINGE BY PBB C 1 OFFICE — PASSAGE SET 44 1/2" x 74 1/2" FALCON F101 D, 2 3/4" ASA 26D LEVER BOTH SIDES 1 WALL STOP: HAGAR 236W CONCAVE 32D H5 (COLOR) BRUSHED ALUMINUM 1 1/2 PR. BUTTS: 4 1/2x4 1/2 H3 HAGAR BB1279, US26D 1 UNIVERSAL GRAVITY HINGE 1 PRIVACY SET 1 FLOOR SUPPORT HINGE PIN FALCON G102D -26D LEVER NOTE: 1 WALL STOP: HAGAR 236W CONCAVE 32D THIS DOOR, FRAME & HARDWARE TO BE SUPPLIED BY R.A.C. NOTE: ABOVE 2 ITEMS ARE INCLUDED TO SHOWROOM FLOOR (TYPE A, B OR WITH DOOR PACKAGE HAVE WINDOW BLINDS. (PLANTATION STYLE WHITE, SIMULATED WOOD). ALL EXTERIOR DOORS TO HAVE H3A (lHR FIRE RATED) BRUSH TYPE WEATHER STRIPPING z :D m APPLIED. 1 PLEXIGLASS KICKPLATE @ 32" A.F.F. Ln (DISPLAY AREA SIDE) EQUAL HARDWARE SUBSTITUTIONS 1 1/2 PR. BUTTS: 4 1/2x 4 1/2 PB81 26D BY PBB WILL BE ACCEPTABLE. 1 OFFICE PASSAGE SET DATE 1 CLOSER: DORMA 7601 PA AL 6/23/09 FLUSH BOLTS: HAGAR 283D -626 (TOP ONLY) 1 SET SMOKE GASKETS 1 WALL STOP: HAGAR 236W CONCAVE 32D (IF REQUIRED) WINDOW SCHEDULE TYPE WINDOW SIZE ROUGH OPENING REMARKS A 42 "H x 36 "W 44 1/2" x 38 1/2" PAINT TRIM BOTH SIDES B 42 "H x 42 "W 44 1/2" x 44 1/2" PAINT TRIM BOTH SIDES C 42 "H x 72 "W 44 1/2" x 74 1/2" PAINT TRIM BOTH SIDES ALL WINDOWS LISTED ARE SUPPLIED & GLAZED ON SITE BY CONTRACTOR WITH 1 PIECE 1/4" CLEAR TEMPERED GLASS. TOP OF WINDOW EVEN WITH TOP OF DOOR. WHITE RIVER HARDWOODS WOODWORKS, INC. MODEL # CA356 11/16"x2 1/4" WOOD CASING OR APPROVED EQUAL. N O a WINDOW SIZES — < 12 FT WALL USE TWO 36 "W x 42 "H WINDOWS > 12 FT WALL USE ONE 42 "W x 42 "H WINDOW 1. ALL OFFICE WALL WINDOWS EXPOSED TO SHOWROOM FLOOR (TYPE A, B OR C) TO HAVE WINDOW BLINDS. (PLANTATION STYLE WHITE, SIMULATED WOOD). 0 r 2, WINDOWS BETWEEN OFFICES SHALL HAVE NO WINDOW BLINDS Q) TYPE 4 EPHOLE FINISH: MATCH ADJACENT SURFACES METAL DOOR 4'- 0 "x7' -Q" SOLID -CORE STIFFENED REAR EXIT DOOR DOOR FINISH: CLEAR POLY TYPE 5 3'- 0 "x6' -8" SOLID CORE BIRCH OR OAK DOOR RESTROOM DOOR j: DAN R. WIN FER AR -241 8 a� s DRAWN BY MVB SHEET NO. A -2 �U z W U � W z I- u� Q � 0-) N N O a O Cr- C z z 0 r U Q) z :D m o Ln +-� t� 00 W 't ry PROJ, NO RA C,002 DATE REVISED 6/23/09 04/09/09 DRAWN BY MVB SHEET NO. A -2