Loading...
HomeMy WebLinkAboutAPPLICATIONS, CO, MULT DOCS - 05-00056 - The Village Apartments - Bldg 11 18 Units CITY OF MULTI FAMILY RESIDENTIAL REXBLIRG AMERK:A5 (AMILY COMMUNIi~Y City of Rexburg Department of Community Development 19 E. Main St. / Rexburg, ID. 83440 Phone (208) 359-3020 /Fax (208) 359-3022 Project Information Permit # OS 00056 Permit Type Multi Family Residential Project Name Village Bldg 11 18 Units Site Address 490 PIONEER RD Parcel # RPRXBCA0255093 Project Description Village Bldg 11 18 Units Names Associated with this Project Type Name Contact Phone # License # Exp Date Applicant Westbrook Development Owner Mckinley Sands Contractor Hill'S Plumbing Destry Hill 208-521-3315 11191 07/31/2006 Contractor Hill'S Plumbing Destry Hill 208-521-3315 1602 08/31/2006 Contractor Westbrook Development Cameron Mckinley 208-520-5939 9999 12/31/2006 Fixtures 1 - C-Sprinkler 1g _ R-fuel (gas) piping fixture or appliance outlet 18 - R-bath fan vents 18 - R-Additional exhaust or vent ducts 18 - R-dryer vents 18 - R-Furnace /Air Conditioner Combo 6 - R-Space Heater - R-Hot Tub /Spa 18 - R-Garbage Disposal 18 - R-Water Softener 18 - R-Water Closet and/or Urinal 18 - R-Clothes Washing Machine 18 - R-Dish Washer lg - R-Floor Drain 18 - R-Water Heater 36 - R-Sink (Lavatory, Kitchen, Mop or Bar Sink) 18 - R-Tub and/or Shower Unit 18 - R-Sprinkler Print Name Date Issued: Signature Date Issued By: CITY OF MULTI FAMILY RESIDENTIAL REXBLIR~ City of Rexburg APIERIG5 fAMM.Y COMMUIVfTY Department of Community Development 19 E. Main St. / Rexburg, ID. 83440 Phone (2081359-3020 /Fax (208) 359-3022 Project Information Permit # OS 00056 Permit Type Multi Family Residen tial Project Name Village Bldg 11 18 Units Site Address 490 PIONEER RD Parcel # RPRXBCA0255093 Project Description Village Bldg 11 18 Units Fee Information Project Details Apartment Buildings - Type V A Wood Frame 15,384 SQFT Project Valuation $930,885.84 Building Permit Fee 5,281.00 Plan Check Fee 528.10 Residential Plumbing Permit Fee 1,812.00 Water Meter & Parts 1,518.20 Hookup Fee/Water 1,334.00 Hookup Fee/Sewer 905.00 Park Impact Fee 6,245.82 Police Impact Fee 243.72 Fire Impact 1,249.74 Base Fire Fee 150.00 Mechanical Fee Base 1,970.00 Automatic Fire-Extinguishing System 100.00 Fire Alarm and Detection Systems Fi: 100.00 Total Fees Paid $21,437.58 Print Name Date Issued: Signature Date Issued By: ~~ ~gEXSURCr9 CITY o F Certificate of Occupancy m ~T City of Rexburg ~'~ ° 1~~ V 1\G Department of Community Development cii, 19 E Main St./Rexburg, ID 83440 ,, America's Family Community Phone (208) 359-3020/Fax (208) 359-3024 a~ ~~rNFD 19 Building Permit No: 05 00056 Applicable Edition of Code: International Building Code 2003 Site Address: 490 Pioneer Rd Use and Occupancy: The Village, Bldg 11, 18 Units Type of Construction: Type V, 1 Hour Design Occupant Load: Apartments Sprinkler System Required: No Name and Address of Owner: McKinley Sands 33801 1St Way SO Suite 281 Federal Way, WA 98003 Contractor: Westbrook Development Special Conditions: Occupancy: Residential, hotels, apartments, more than 10 persons This Certificate, issued pursuant to the requirements of Section 109 of the International Building Code, certifies that, at the time of issuance, this building or that portion of the building that was inspected on the date listed was found to be in compliance with the requirements of the code for the -group and division of occupancy and the use for which the proposed occupancy was classified. Date C.O. Issued: April 6, 2006 C.O. Issued b Y Building Official There shall be no future change in the existing occupancy classification of the building nor shall any structural changes, modifications or additions be made to the building or any portion thereof until the Building Official has reviewed and approved said future changes. A Water Department~~ Fire ~epa~I~t: ~Uy--., State of Idaho Electrical Department (208-356-4830): G ;~~ CITY OF REXB URG • -BUILDING PERMIT APPLICATION 19 E MAIN, REXBURG, ID. 83440 208-359-3020 X326 PARCEL NUMBER: SUBDIVISION: OWNER: PROPERTY ADDRESS: `rt~ UNIT# BLOCK# LOT# CONTACT PHONE # ~~y - ~~t-j - ~7L.e ('~ c PHONE #: Home (p7~~ ~ ~ ` ~f7 (t ~ Work (~C8) ~~t+-~ -~1 ~Q b Cell (~o~' S'a p - cq ~ ~ OWNER MAILING ADDRESS:~11 ~,. WO~r~ ~kCITY: lc~e~ ~aIIS STATE:_(f~ZIP:~ APPLICANT (If other than owner) (If applicant if other than owner, a statement authorizing applicant to act as agent for owner must accompany this application.) MAILING ADDRESS OF APPLICANT CITY: PHONE #: Home ( ) VS 'UOVS~ Plea n! if the y Village Building 11 1 K Units ~e Work ( ) STA' Cell ZIP CONTRACTOR:1~~~k (~~Opm~HONE: Home ~'~f7l,t(~Work#~~-1J7~3Ce11# ~,f_~3~ MAILING ADDRESS: ~,? t ~ S - YV ~:~~-trr~ Sake ~ CITY~~a~ ~'al~s STATE ~ Y~ ZIP ~~ ~ How many houses are located on this property? M,U,1`Tl `~~m't~U Did you recently purchase this property?~ Yes (If yes give owner's name) Is this a lot split YES (Please bring copy of new legal description of property) PROPOSED USE: ~v~~k1-~c'sm~~ (i.e., Single Family Residence, Multi Family, Apartments, Remodel, Garage, Commercial, Addition, Etc.) APPLICANT'S SIGNATURE, CERTIFICATION AND AUTHORIZATION: Under penalty of perjury, I hereby certify that I have read this application and state that the information herein is correct and I swear that any information, which may hereafter be given by me in hearings before the Planning and Zoning Commission or the City Council for the City of Rexburg shall be truthful and correct. I agree to comply with all City regulations and State laws relating to the subject matter of this application and hereby authorized representatives of the City to enter upon the above-mentioned property for inspections purposes. NOTE: The building official may revoke a permit on approval issued under the provisions of the 2000 International Code in cases of any false statement or misrepresentation of fact in the application or on the plans on which the permit or approval was based. Permit void if not started within 180 days. Permit void if work stops for 180 days. Signature of Owner/Applicant .3 / ~ / oS DATE WARNING -BUILDING PERMIT MUST BE POSTED ON CONSTRUCTION SITE! Plan fees are non-refundable and are paid in full at the time of application beginning January 1.2005. City of Rexburg's Acceptance of the plan review fee does not constitute plan approval **Building Permit Fees are due at time of application** **Building Permits are void if you check does not clear** • o Please complete the entire Application! ' a If the question does not apply fill in NA for non applicable NAME ~ V~ j+ ~ PROPERTY ADD SS y~h ~joneey ~ Permit# ~ ~~'~S SUBDIVISION Dwelling Units: SETBACKS FRONT SIDE SIDE Front Footage (if applicable) Storm Water Length Water Meter Size: SURFACE SQUARE FOOTAGE: (Shall include the exterior wall measurements of the building) r ~Il~~~a First Floor Area 5 ~ ag' Unfinished Basement area ~~ Second floor/loft area ~ 1'a ~"' Finished basement area hh4 Third floor/loft area ~~ ~ ~ Garage area 1.1-A Shed or Barn ~~ Carport/Deck (30" above grade)Area Remodel (Need Estimate) $ Water Meter Count: PLUMBING Plumbing Contractor's Name: ~,MrQ ~r~~~ Business Name: ~~~~~~ ~~ih~ £ pQ~~, ~, Address_C~3t-I b ~~5~- L.t nd ~ }~irnrnc~n State [ D Zip ~3 i~ Contact Phone: (~a~) S'~- 9- 9'715 Business Phone: (aag )_Caa ~t-q`(~ S' FIXTURE COUNT (including roughed fixtures) f ~ Clothes Washing Machine ~_ Dishwasher ~ Floor Drain c~ Garbage Disposal O Hot Tub/Spa Sinks (Lavatories, kitchens, bar, mop) Plumbing Estimate $ (Commercial Only) BACK Sprinklers ~u~~ ~~ ~r~'J Tub/Showers ~~ Toilet/Urinal ~~ Water Heater Water Softener Signature of Licensed Contractor License number Date The City ofRexburg's permitfee schedule is the same as required by the State ofldaho Parcel Acres: 2 • ,~ Please complete the entire Application! If the question does not apply fill in NA for non applicable NAME ThQ Ui l lei PROPERTY ADDRESS 4~1~ ~~~~.~~ ~~ SUBDIVISION Permit# ~~ t~ S ~ ~ ~ f 2 MECHANICAL , , Mechanical Contractor's Name: QYyG~ 7 f ~ Business Name: J~~~~S ~11~~~'~-g ~~7`~'~J Address ~~~~ ~'aSf' ~r~~ ~n'Jp1'7 State ~ Q ZipZ { T Contact Phone: ~~ C~,~ --~''j( ~ Business Phone: O ~q - 9''/5 Mechanical Estimate $~ (Commercial/Multi Family Only) `a ~ FIXTURES & APPLIANCES COUNT (Single Family Dwelling Only) ~ ~ Furnace ~~ Exhaust or Vent Ducts °t Furnace/Air Conditioner Combo X30 ~~ / ~ Dryer V ents / Heat Pump Air Conditioner Evaporative Cooler Unit Heater Space Heater ~`~~ Range Hood Vents Cook Stove Vent~~~ ~, ~~ Bath Fan Vents Decorative gas-fired appliance Incinerator System Boiler Pool Heater Similar fixtures or Appliances ~~ J . Fuel Gas Pipe Outlets including stubbed in or future,ou lets Heat (Circle all that apply) -Gas Oil Coal Fireplace Electric other similar vents & ducts: ~~~~~ Mechanical Sizing Calculations must be submitted with Plans & Application Point of Delivery must be shown on plans. Signature of Li ensed Contractor License number Date The City of Rexburg s permit fee schedule is the same as required by the State ofldaho 3 1 ~ ~, ~ ~ MC SQUARED INCORPORATE D February 14, 2045 Glenn Wells, AIA Fax: (360) 352-7867 Re: The Village Apartments Phase 2 in Rexburg, Idaho Buildings 8, 9, 10, 11, 12 & 13 Project #24214.03 Dear Mr. Wells, 1235 EAST 4TH AVE SUITE 101 OLYMPIA, WA 98506 (360) 754-9339 FAX (360)352-2044 E-mail: eng®mc2-inc.com We were asked to revise the drawings and calculations for Phase 2 buildings 8, 9, 10, 11, 12 and 13 to reflect a 3/4" gypcrete topping on all the floors in this phase of the apartments. I have revised the calculations for the increased dead load on the floors and found that all units in phase 2 can handle the increase in dead load with only a few minor changes in unit types A & B. All buildings that have a unit A & B will need to be revised per the attached plans. If you have any questions please call me at (360) 754-9339. Sincerely, MC Squared, Inc. ~~ ~~~ Chalese Smartt Senior Ass ~ iate Engineer L,~ . Mike Szramek, P. . Principal Engineer t~~oS STRUCTURAL • FOUNDATION • CIVIL ENGINEERS • • aj~ slMPSON Hrrzz IN OBL 2x STUDS TO FOUNOA710N !I Pi f2 HF 4x4 W/ SIMPSON EPC44 Pi /2 HF -~---- SINPSON HR78 IN ~ ~ ~ PT /2 HF - OBl 2x TO FDN O T8' 0. TYP. se.2 , i ' i I I I z z ~~ 31 I I{2 HF 4x8 I 'III - ~~ ~''I~I - ~i ri r -n -~I-T - - ~ ~; OF I ~ ~ J III I I I I I I I ti+ ~ I I I I I I I I I I I I~~"~ o I I I I I I IIII I I I I °~ ~ ~ .-_ - I I I I ( II I I I I II I I I I I I I UNR A I I 11 I I I I I I ~ ~I ( I I I I Iu I I I I i i III 1 I SIMPSON HTT22 IN OBL 2x I STUDS TO FOUNDATKN - I I i Ii 1 I 12 I I I I I I I I II I I i u I I l I ~~ ~S I I I I n l II ~ I L 1n I I I uNR e I I I Ii11 I I lyi_xlt ;~_ I ~ !` 11 ~ I ,D II I ' _ TYP. I I ~ ~ ~ - - I I I I ~~ - I-I I I TI~~1I ,, I I II -7- ~ o I~ ~ ~ ~ e~3.7'16 I I I I I I AT EACFI END ~ I I ~~ 1 - I ~ ~o oP' I ~ I I I I I I I I~ ~ ~ I I I A'"' II I I I~ I I I: - "'"u '-- -~~ ~I II ;le~° II NT TO III~~ I ~L __ O~fT T I I I I t4 I I ~ ~ I EXIT ~• sax (1 ,.\° i I I I I I I I ;y4xt 1 ~6 Ps II I I ~ ~ ~ JII -r-r---~ I I-I J ~ ~q ~ I I c4) c - - ~~4K _ I I I I I I I I~ I I i I I I II I I I I _ll -~~ i _-JI IIIII I I "' I I I 'I II ~ I I -~ (~---~ III I I I g~~ GAB W- I s I I I I- I _ i1 I I i 1-~ ~H ~ D I I I I I TrP. ~° III I I I I I I I I a ~ ~ SIMPSON HTI'22 IN DBL I I I I I I 2z STUDS TO FOUNDATION I I I I'Il I I I / I I uNR A I I I i = I I I I i 1 1~ z- 'II II IIII I~ I I I I III 1~-~ 1 2 ---g-- z I I ~f ~I I I I- I , I _JLJI--~.~1 I, - ~~rzHFex6 ( I I I ~' 2x STUDS TO FOUNDATION SECOND FLOOR FRAMING PLAN vg- a r.c i t1~, ~' ~11~~e ~p~~+~-~}~ - Ph~~~ ~ NOTES: USE /2 OF 6x8 HEADER W/ OBL 2x8 TRIMMERS do DBL 2x6 KING STUDS AT ALL EXTERIOR OPENINGS. UNLESS NOTED OTHERWISE. USE /2 OF 4x8 HEADER W/(2) TRIMMERS AT ALL INTERIOR BEARING WALL OPENINGS. UNLESS NOTED OTHERWISE. Q -TYPICAL SHEARWALL CALLOUT. SEE SHEARWALL NOTES F~ NAILING SCHEDULE THIS BUIlDINO IS DESIGNED FORA 3/4' GYPCRETE OOR TOPPING SLAB. e 7 FOR TYPICAL BRICK NTAL, SEE DETAIL - ~,y FOR TYPICAL SHEARWALL ELEVATION, SEE DETAIL - ~ I ss.2 . ' - ~ ~~ -~ SIMPSON MST37 IN 08L 2x. SEE e O se.x ~~ se.x I I I II =~ ~=~~Iri r~r I I ~ ~ IIII I I I I I II I I I I I I I I III I I I I I II ' I I II I I I I Ii~ I I I uNrr A I I III I I I I ~. _~.-IIII I I LJ I _ _ II ~ I .~- ~ I MPSON M u I I I BL 2x. SEE I ~I ~ I PT /2 HF 2x8 O 16' O.C. PT /2 HF 4x4 W/ SIMPSON EPC44 _ _ ~PT /2 I I ~ I I I i i ~ ~~ i /2 HF 4x8 - _ ~Q --~ --I} I ~2 ~E~ I- I I I So b y.l I I I I ~- - j I I I I I I I I I I III I I I I ,2 I I I ~ I I II 5~ III III-II ~~~ I I I I L- I I I ICI I I I ly5_x, I _ I UNff 6 I II~~~ 10 I~ TYP I I I I ~ I I 1 ~~~ OG. - ~6~~ ~ II _ I I gIpNT ~,, I I I L IOR WALI~.S ~ I ~_ I-~ ~~ R _, _ -fir = -~ -~I II I I I III 14 I I II TI I I ~ ~ I I ' I I I I~ c I I -- I, X21 ~ II~ j IL Imo.- '~---- I IIII I -.-~- ~ I , I ~ W/(3) 2x STUDS II AT EACH END 0 II III I I I I 11es~~ti`°. °G I I I I I I o IIII=I I __ ''~ I I I I I ~~~ I~ w ~~° I U I I I J ` I x, w ~ II -T-- - I O IIII I I I F 4xiQ II _ III II IIIII~IIII IIII -~ I I -~~I ~~=--JJ IIII I I I f~ ~ ~ II APSON MSTJ7 N I 'xs cLe W_ I s I IN OS L~ 2x 3~ I_ I - I I I I I ~ 0 ~~ TYP. I SS.z II II _ ~II ~ IIII I I II I~- II ~" III I I IIII I I I S - III (IIII F I I I uNrr n I I I _ _ I I I I I I L II _ _ II ' ~ I ~~~_ VIII III ~~ ~ ~ I I I I I II I. I ~ ~ o I~-~~_ I I. ( I ( -~ ~ ~ ~ PT /2 HF 8x8 I I I ~~~ ~ ~ w/ POST CAP ~~_~ SIM 7 IN ~~~/// OBL 2x. SEE e 50.2 THIRD FLOOR FRAMING PLAN 1A1" • 7'-0" ---~- 2 SIMPSON MST37 IN DBl 2x. SEE -.e 50.1 NOTES: USE /2 DF Bx8 HEADER W/ DBL 2x6 TRIMMERS B OBL 2x6 TONG SPUDS AT ALL EXTERIOR OPENINGS. UNLESS NOTED OTHERWISE. USE ~2 DF 4x8 HEADER W/(2) TRIMMERS AT ALL INTERIOR BEARING WALL OPENINGS. UNLESS NOTED OTHERWISE Q -TYPICAL' SHEARWALL CALLOUT. SEE SHEARWALL NOTES FOR NAIL1NC SCHEDULE. _ 1' THIS BUILDING IS DESIGNED FOR A :~/~' GYPCRETE BOOR TOPPING SLABTOPPING SUB.