Loading...
HomeMy WebLinkAboutPLANS - 05-00018 - Family Dollar - RemodelGeneral Notes FAMILY DOLLAR STORES, INC. PROJECT N0. C -10 157 N 200 EAST REXBURG, ID PROJECT CONTACT LIST: O WNER: FAMILY DOLLAR STORES P.O. Box 1017 Charlotte, North Carolina 28201 Local Contact (801) 546 -0684 CONTACT PERSON: BRYON SCOTT ARCHITECT RALPH F. EVANS 1074E 2100 S SALT LAKE CITY, UTAH 84106 (801) 466 -3738 INDEX OF DRAWINGS: ARCHITECTURAL AO.0 TITLE SHEET, LIST OF CONSULTANTS AO.1 SPECIFICATIONS A1.0 DEMO PLAN A2.0 FLOOR PLAN, INTERIOR ELEVATIONS A3.0 REFLECTED CEILING PLAN /LIGHTING PLAN A4.0 DOOR AND FINISH SCHEDULES, DETAILS A5.0 DETAILS CODE ANALYSIS: 1. THE CONTRACTOR SHALL CONFORM TO ALL CODES, ORDINANCES, ETC.. WHICH HAVE JURISDICTION OVER THE WORK. THE CONTRACTOR SHALL RETAIN RESPONSIBILITY FOR COMPLIANCE WITH THE LATEST REVISIONS OF ALL CODES AND ORDINANCES, INCLUDING THE FOLLOWING: BUILDING CODE: 2003 IBC, ANSI A117.1 -1998 CONTACT PERSON: RALPH EVANS CITY: REXBURG, ID INTERIOR DESIGNER: MARIDADI 1074E 2100 S SALT LAKE CITY, UTAH 84106 (801) 466 -3738 CONTACT PERSON: LEANN KAMAU OCCUPANCY: GROUP M (RETAIL) CONSTRUCTION TYPE: IIB(ASSUMED) NON- SPRINKLERED PROJECT AREA: 9 SF 7,788 SF (SALES AREA) 307 SF (SALES SUPPORT) 725 SF (NET STORAGE) SF (MISC) OCCUPANCY LOAD: 1/30 SF (SALES AREA) 1/300 SF (STORAGE) EXITS PROVIDED: 2 EXITS U Z 2 • 1 M E-- U W O n Revision /Issue ME Firm Nome and Address MARIDADI 1074 E. 2100 S. SL C, UT 84106 Project Name and Address THE REMODEL OF EXISTING RETAIL SPACE. THE CONSTRUCTION PHASE CONSISTS OF SOME DEMOLITION, AND THE CONSTRUCTION OF NEW WALLS, AND TOILET ROOMS FOR THE TENANT'S NEW LAYOUT. FAMILY DOLLA STORES REXBURG, ID F -10 Sh TITLE 120105 SHEET 118" =1' -0" AO M 01 o C� c C _- SPECIFICATION FOR TENANT IMPROVEMENT FAMILY DOLLAR STORE PROJECT NO. C -10 PROVIDE: TOILET ROOM FIXTURES AND HARDWARE AS BELOW, WATER AND SEWER LINES. 8. FURNISH AND INSTALL QUAD 20 AMP CONVENIECE ELECTRICAL RECEPTACLE FOR BREAK AREA IN STOCKROOM AS SHOWN. REXBURG, ID 5. PROVIDE HARDWARE MANUFACTURED TO CONFORM TO PUBLISHED 1. TOILET ROOMS SHALL BE EQUIPPED WITH THE FOLLOWING ACCESSORIES FOR 9. FURNISH AND INSTALL DUPLEX CONVENIENCE ELECTRICAL RECEPTACLE AT EXISTING/NEW ELECTRICAL PANEL DIV. 1 - GENERAL REQUIREMENTS TEMPLATES GENERALLY PREPARED FOR MACHINE -SCREW EACH: SEE SCHEDULES SHEET FOR LIST OF APPROVED PLUMBING FIXTURES. 10. FURNISH AND INSTALL DUPLEX IG ELECTRICAL RECEPTACLE AT NEW COMMUNICATION BOARD. SEE 1 EA. 18' x 24' FRAMED WALL MIRROR CONCEALED MOUNTING INSTALLATION. DO NOT PROVIDE HARDWARE WHICH HAS BEEN DRAWINGS FOR LOCATION OF BOARD. 1. PROTECT ANY EXISTING WALLS, FLOOR COVERINGS, FINISHES, ETC.. PREPARED FOR SELF - TAPPING SHEET METAL SCREWS. FURNISH PHILLIPS OVER EACH LAVATORY. INSTALL W/ BASE ® 40' A.F.F. 11. FURNISH AND INSTALL ONE (1) CONVENIENCE CIRCUIT, ONE (1) DEDICATED CIRCUIT NTH THAT ARE TO REMAIN. FLAT HEAD SCREWS, MATCHING ADJOINING FINISH, FOR INSTALLATION 1 EA. TOILET TISSUE HOLDER - BRADLEY MODEL '5054' 18 GA. CHROME PLATED ISOLATED GROUND AND ONE (1) PHONE CONNECTION WITH DUPLEX JACK IN MANAGERS General Notes 2 STEEL OR APPROVED EQUAL. INSTALL W/ CENTER LINE 0 24" A.F.F. OFFICE. INCLUDE ALL NECESSARY BUILDING PERMITS, INSPECTION FEES, AND WITH EACH HARDWARE ITEM. 1 EA. HOOK - BRADLEY MODEL 931 MOUNTED TO DOOR FACE OR 12. FURNISH AND INSTALL DUPLEX CONVENIENCE ELECTRICAL RECEPTACLE FOR ELECTRIC DIV. 17- MISCELLANEOUS CONT , D OTHER CUSTOMARY MUNICIPAL CHARGES. 6. MOUNT HARDWARE UNITS AT HEIGHTS INDICATED IN 'RECOMMENDED 3. GENERAL CONTRACTOR SHALL PERFORM ANY WORK REQUIRED TO CAUSE LOCATION FOR BUILDERS HARDWARE FOR STANDARD STEEL DOORS AND APPROVED EQUAL. INSTALL HOOK ®4' -6" A.F.F. WATER COOLER. 8. PROVIDE FOR ONE DISABILITY ACCESSIBLE PARKIN THE EN11RE DEMISED PREMISES TO COMPLY WITH LAWS PERTAINING TO FRAMES.' INSTALL IN ACCORDANCE WITH MANUFACTURER'S 1 EA. 1 1/4' N x 36' & 42' S.S. CODE APPROVED GRAB BARS WALL (OR FLOOR 13. PROVIDE CONDUIT FOR ALL LOW VOLTAGE WIRING AS REQUIRED BY STATE & LOCAL CODES. SPACE IN CLOSE PROXIMITY TO THE ACCESSIBLE ACCESSIBI BY DISABLED PERSONS AND OBTAIN A CERTIFICATE OF INSTRUCTIONS AND RECOMMENDATIONS, LEVEL, PLUMB, AND TRUE TO MOUNTED ) AS REQUIRED. INSTALL GRAB BARS 0 34' -36' A.F.F. 14. FURNISH AND INSTALL DUPLEX CONVENIENCE ELECTRICAL RECEPTACLE FOR ELECTRIC PATH TO THE DEMISED PREMISES BY PAINTING OCCUPANCY PRIOR TO DELIVERING THE DEMISED PREMISES TO TENANT. LINE AND LOCATION AND IN ACCORDANCE NTH INDUSTRY STANDARDS. 1 EA. ELEC HAND DRYER - INSTALL WITH OPERATING MECHANISM 0 48" A.F.F. BY WATER HEATER. ONE PARKING SPACE AS DISABILITY PARKING MINIMUM 8' WIDE FURNISH AND INSTALL A WEATHERPROOF DOOR BUZZER AT FREIGHT RECEIVING DOOR AND BELL ABOVE CEILING NEAR 15. 4. THE FOLLOWING WARRANTIES SHALL BE GIVEN: ADJUST AND CHECK OPERATION AS NECESSARY. ELECTRIC AIRE MODEL LE -1. DRYER LOCATED ON SIDE WALL TO LAV. ( ) AND PAINTING ONE 5 ' WIDE A. ALL SUBMISSIONS SHALL BE FORWARDED TO TENANT'S REPRESENTATIVE 7. REPLACE ALL CRACKED AND BROKEN GLASS W / GLASS OF EQUAL SPECIFICATION (SUPPLIED BY FDS) , STOREFRONT. ACCESS ISLE DIRECTLY ADJACENT TO THIS SPACE. B. ALL MANUFACTURER'S WARRANTIES FOR NEW EQUIPMENT OR MATERIAL TEMPERED AS REQUIRED 28. FURNISH AND INSTALL WIRING AND HOOKUP FOR DAIRY COOLERS. CIRCUIT SHOULD BE AN ISOLATED GROUND CIRCIUT . ED BY CODE. 1 EA. CODE APPROVED ROOM IDENTIFICATION SIGN INSTALLED ADJACENT TO STRIKE INSTALLED IN THIS PROJECT SHAD_ BE PROVIDED TO THE TENANT IN DIV. 9 . 16. FURNISH WIRING AND HOOKUP FOR DEMISED PREMISE SIGN(S) COMPLETE WITH PHOTOCELL(S). 9. PROVIDE A RESERVED PARKING SIGN (VAN ACCESSIBLE) IF APPLICABLE ON A POLE FOR EACI 2 EA. TOILET SHELF - 8 D C 24 L WHITE. INSTALL Wj SHELF � 46 FULL FORCE• 1. EXTERIOR FINISHES - MATCH EXISTING FINISHES TO THE EXTENT THAT " " " A.F.F. USE VERIFY SIGNS ARE WORKING PRIOR TO FDS POSSESSION. C. ALL NEW HVAC EQUIPMENT SHALL BE WARRANTED FOR NOT LESS THAN ANY EXTERIOR WORK IS PERFORMED AS FOLLOWS: TOILET WHITE ADJUSTABLE SHELF STANDARDS AND SUPPORTS. DISABILITY PARKING SPACE PROVIDED. (60" A.F.F. ONE YEAR AND HAVE A FIVE -YEAR COMPRESSOR WARRANTY. 2. LIGHT GAGE METAL FRAMING - PROVIDE/INSTALL AS SHOWN ON PLANS. 17. FURNISH WIRING AND HOOKUP FOR ROAD SIGN(S) COMPLETE WITH PHOTOCELL(S). TO BOTTOM OF SIGN) D . 3. PROVIDE COMPLETE NEW HVAC EQUIPMENT AS REQUIRED TO BRING THE TOTAL AIR CONDITIONING SYSTEM VERIFY SIGNS ARE WORKING PRIOR TO FDS POSSESSION. 9. RESTRIPE PARKING LOT IN EXISTING PATTERN. ALL MATERIALS, EQUIPMENT, AND INSTALLATIONS SHALL BE WARRANTED A. PROVIDE WALL AND CEILING FRAMING OF THE TYPE SHOWN ON WITH THE FOLLOWING MINIMUM STANDARDS: 18. FURNISH WIRING AND HOOKUP FOR UNDER CANOPY SIGN COMPLETE WITH PHOTOCELL (S). FOR A PERIOD OF ONE YEAR FROM DATE TENANT FENS FOR BUSINESS. PLANS UTILIZING 3 -5/8' STUDS AT 24' (UNLESS OTHERWISE TO THE DEMISED PREMISES IN COMPLIANCE (S ) (). STANDARDS: VERIFY SIGNS ARE WORKING PRIOR TO FDS POSSESSION. 9. PLACE PARKING LOT LIGHT FIXTURES IN WORKING E . TEST ALL HVAC UNITS FOR A/C AND HEAT PRIOR TO POSSESION OF SPACE NOTED} ON CENTER AND RUNNERS COMPLYING WITH STANDARDS: MINIMUM OF TWO COMMERCIAL MERCIAL GRADE SPLIT SYSTEM OR ROOFTOP UNITS SHALL F. SEPARATE METER IS NOTED AS AN INDIVIDUAL METER TO SPACE NOT ASTM C 645, WITH FLANGE EDGES OF STUDS 22. SPLIT EXISTING ELECTRICAL SERVICE TO PROVIDE EXCLUSIVE SERVICE TO THE DEMISED PREMISES CONDITION 'SUB - METERED" BENT BACK 90 DEGREES AND DOUBLED OVER TO FORM 3/16' BE PROVIDED TO SERVICE THE DEMISED PREMISES. INCLUDING SEPARATE METER, 400 AMP 3 PHASE PANEL, 120V/280V WITH 30 BREAKERS MIN. INSTALLED ON PANEL. 9. MAKE REPAIRS TO ROOF, FLASHING, GUTTERS, AN 5. PROVIDE SEPARATE TRASH RECEPTACLES OR DUMPSTER AND BE MINIMUM WITH; 0.0179' MINIMUM THICKNESS OF BASS METAL, B. UNITS SHALL BE SIZED TO PROVIDE A MINIMUM OF ONE (1) TON OF COOLING DOWNSPOUTS TO PUT IN WATERTIGHT CONDITION, RESPONSIBLE FOR THE REMOVAL OF ALL TRASH AND DEBRIS RESULTING B. USE HAT - SHAPED OR Z -TYPE FURRING MEMBERS AGAINST FOR EACH 400 SF OF SPACE. FROM LACE EXISTING CANOPY /MANSARD IN GOOD REPS THE WORK. DISPOSE OF IN APPROVED LOCATIONS. MASONRY OR CONCRETE WALLS AND SCREW TYPE FASTENERS FOR G. HEATING SHALL BE PROVIDED TO CONFORM TO THE FOLLOWING SCHEDULE, BASED 9. P 'S SPECIFICATIONS. 6. PROVIDE PERIODIC CLEANUP, CLEANING OF ANY COMMON AREAS ALL ATTACHMENTS AND CONNECTIONS. 8,000 SF BUILDING SIZE: (THIS REQUIREMENT SHOULD BE ADJUSTED PROPORTIONALLY PAINT PER TENANAT OUTSIDE OF THE WORK AREA THAT ARE SOILED AS A RESULT OF THE C. PROVIDE CEILING SUPPORT MATERIALS AND SYSTEMS WHERE FOR SPECIFIC LOCATIONS) 19. REWORK EXISTING ELECTRICAL PANELS AS NECESSARY TO CONFORM TO STATE AND LOCAL CODES. 9. CLEAN AND PAINT UNDER CANOPY USING SHERWII WORK, AND FINAL CLEANUP OF THE PREMISES UPON COMPLETION. GYPSUM SOFFITS OR CEILINGS ARE CALLED FOR INCLUDING ALL ZONE I NORTH OF NORTH LATITUDE 38 DEGREES 20. PROVIDE ONE (1) BLANK DUPLEX RECEPTACLE BOX (W/ PULL STRING) WITH 1" CONDUIT RUN UP THROUGH WALL TO ABOVE WILLIAMS SW 1004 PURE WHITE CLEAN EXTERIOR WINDOWS AND GLIDING AS WELL AS THE INTERIOR SIDE RUNNERS, HANGER WIRE, FURRING MEMBERS, ANCHORAGE 80 KW OF ANY NEW OR EXISTING GLIDING. REMOVE AL TAPE, DECALS,ATTACHED DEVICES ETC. THE CEILING. IF THE OFFICE IS LOCATED IN THE RECEIVING ROOM RUN CONDUIT UP WALL AND PENETRATE THROUGH TO GLASS OF MULLIONS. ZONE it SOUTH OF 38 DEGREES AND NORTH OF 32 DEGREES RECEIVING ROOM WALL. PROVIDE PROPER FIRE SEALANT AS REQUIRED PER CODE W/ END CAP. INSTALL NEXT TO D. COMPLY WITH ASTM C 754 INSTALLATION STANDARD. INSTALL 60 KW PHONE BOX IN MANAGER'S OFFICE FOR FUTURE USE BY FAMILY DOLLAR. 7. COMPLY WITH MANUFACTURER'S INSTRUCTIONS AND CEILING AND WALL PARTITION SUPPORTS SYSTEM IN ACCORDANCE ZONE III SOUTH OF NORTH LATITUDE 32 DEGREES 21. PROVIDE A (1') ONE FOOT PIECE OF 3' CONDUIT RUNNING THROUGH THE RECEIVING ROOM WALL AT (3) THREE LOCATIONS. RECOMMENDATIONS FOR ALL INSTALLATIONS. PROVIDE ATTACHMENT WITH APPLICABLE PUBLISHED RECOMMENDATIONS OF GYPSUM 40 KW ALL THREE PIECES WOULD BE LOCATED 12' ABOVE THE CEILING. ONE PIECE WOULD BE CENTERED ON THE WALL AND THE OTHER AND CONNECTION DEVICES, BLOCKING, SLEEVING, AND EMPLOY BOARD MANUFACTURER AND OF 'GYPSUM CONSTRUCTION INDUSTRY ACCEPTED METHODS FOR SECURING WORK. INSTALL WORK HANDBOOK' PUBLISHED BY UNITED STATES GYPSUM CO. D. PROVIDE DUCTED SUPPLY AND RETURN AIR WITH CEILING DIFFUSERS TO SALES TWO PIECES WOULD BE LOCATED 5' FROM THE LEFT AND RIGHT DEMISING WALL. SAID CONDUIT SHOULD BE FIRE CAULKED &CAPPED, AREA, RECEIVING ROOM, TOILET ROOM AND OFFICE. AS REQUIRED BY CODE, FOR FUTURE USE BY FAMILY DOLLAR. TRUE TO LINE, LEVEL, AND PLUMB. E ISOLATE STUD SYSTEM FROM TRANSFER OF STRUCTURAL LOADING E. EACH UNIT SHALL BE CONTROLLED BY LIGHTSET THERMOSTATS (SUPPLIED BY FDS) 22. INSTALL ELECTRIC HAND DRYER (MODEL LE1 -WHITE ELECTRIC AIR) AND FINAL 8. FIELD VERIFY ACTUAL DIMENSIONS AND LAY OUT WORK IN BOTH HORIZONTALLY AND VERTICALLY. PROVIDING SLIP OR MOUNTED 8' -0" A.F.F. ON INTERIOR COLUMNS. ELECTRICAL CONNECTIONS. SUPPLIED BY FDS. INSTALL AT 48' A.F.F. TO THE BOTTOM OF UNIT. PROVIDED BY FDS. ACCORDANCE WITH PUNS, NOTIFY PROJECT MANAGER AND OBTAIN CUSHIONED TYPE JOINTS TO OBTAIN LATERAL SUPPORT AND COORDINATE THERMOSTAT LOCATION WITH TENANT'S CONSTRUCTION REPRESENTATIVE. 23. FURNISH AND INSTALL A 20 AMP CIRCUIT FOR RECEIVING ROOM HEATER AT REAR DOOR. INSTRUCTIONS WHEREVER ACTUAL CONDITIONS VARY FROM THOSE AVOID AXIAL LOADING. EXTEND PARTITION STUD SYSTEM F. ALL WORK SHAM BE DONE IN COMPLIANCE WITH LOCAL CODE REQUIREMENTS 24. LABEL ALL PANEL AND BREAKER BOXES. SHOWN ON Pte• THROUGH ACOUSTICAL COUNGS EXCEPT AS OTHERWISE INCLUDING FRESH -AIR MAKEUP, ECONOMIZERS, FIRE DAMPERS, SMOKE DETECTORS, ETC. 9. COMPLY WITH ALL PROVISIONS OF THE LATEST EDITIONS OF APPLICABLE INDICATED AND BRACE TO STRUCTURAL DECK. 25. FURNISH AND INSTALL DUPLEX CONVENIENCE RECEPTACLE FOR SECURITY MONITOR. RUN WIRES AS PER STATE AND LOCAL 3. CODES. G. FAMILY DOLLAR HAS A NATIONAL ACCOUNT W/ CARRIER & YORK FOR HVAC EQUIPMENT. GYPSUM WALLBOARD - PROVIDE AND INSTALL AS SHOWN ON PLANS. CODES THROUGH HOLLOW SUPPORT TUBE AND MOUNT DUPLEX ON REAR SIDE OF TUBE. LOCATE AS PER CUT SHEET CONTACT BOB BERG W CARRIER AT 615 - 986 -1533 AND USA KUHNS W/ YORK 10. G.C. TO PROVIDE TEMPORARY UTILITIES TO THE SPACE A UNITED STATES GYPSUM "SHEETROCK' IS STANDARD OF QUALITY. AT 405 -419 -6535 535 FOR FOR SUPPLIED BY PM. INSTALLED BY G.C. INFOR ATION. 26. FURNISH AND INSTALL DUPLEX CONVENIENCE RECEPTACLE FOR SECURITY PANEL LOCATE NEXT TO PHONE JUNCTION FAMILY DOLLAR STORES WILL PROVIDE PERMANENT POWER FOR COMPLY WITH ASTM C 36 FOR EXPOSED GYPSUM BOARD, 5/8' 3A. SUPPLY AND INSTALL SMOKE /FIRE DETECTION SYSTEM IN ALL NEW AND EXISTING MECHANICAL SYSTEMS BOX (D -MARK) BY THE ELECTRICAL PANELS. TRANSFER AT COMPLETEION OF CONSTRUCTION ANS POSSESSION OF SPACE. THICK, TYPE 'X' FIRE CODE WITH TAPERED EDGE. USE EXTERIOR AS REQURED BY CODE. 27. FURNISH AND INSTALL DUPLEX ELECTRICAL OVER WINDOWS AS NECESSARY TO MEET LOCAL CODE. G.C. SHALL ARRANGE FOR TELEPHONE SERVICE AT THE SITE OR PROVIDE GRADE OR WATER RESISTANT TYPES IN AREAS RECOMMENDED BY 4. G.C. TO PROVIDE TEMPORARY UTILITIES TO SPACE. FDS WILL PROVIDE POSEESSON OF SPACE BY FDS. 28. FURNISH AND INSTALL WIRING AND HOOKUP FOR HIRING KIOSK. CIRCUIT SHOULD BE AN ISOLATED GROUND CIRCIUT MOBILE UNITS SO THAT DESIGNER IS ABLE TO COMMUNICATE TO THE MANUFACTURER. 5. CLEAN OUT EXISTING SEWER LINES A MINIMUM OF 250 L.F. SHJLL BE TERMINATED AT A JUNCTION BOX ABOVE SALES AREA CEILNG WITH FINAL CONNECTION MADE TO SPECIAL PLUG JOB SITE DURING ALL NORMAL WORKING HOURS. B. PROVIDE CORNER BEADS, METAL TRIM, PERFORATED TAPE, AND 6. PROVIDE AND INSTALL ANY NECESSARY FIRE ALARM MONITORING SYSTEMS (FOR MONITORED AND NON - MONITORED SYSTEMS) IN GREEN PIGTAIL CONNECTOR. 11. PROVIDE SUBMITTALS FOR ANY OF THE FOLLOWING THAT ARE CALLED DWA -14 ADHESIVES AND OTHER MISCELLANEOUS MATERIALS IN ACCORDANCE WITH ANY /ALL LOCAL OR STATE FIRE DETECTION REQUIREMENTS. FORWARD ALL DRAWINGS OF SAID LIGHTING OUT ON THE PLANS: ELECTRICAL FIXTURES, PLUMBING FIXTURES, HVAC REQUIRED. FASTEN WITH GYPSUM BOARD SCREWS COMPLYING DETECTION SYSTEM SYSTEMS TO TENANT CONSTRUCTION REPRESENTATIVE PRIOR TO INSTALLATION. 1. TENANT HAS A NATIONAL ACCOUNT FOR THE PROVISION OF LIGHT FIXTURES TO BE EQUIPMENT AND CONTROLS, CABINETRY SHOP DRAWINGS, BASS AND WITH ASTM C 646 AND C 1002. 7. PROVIDE AND INSTALL NEW ELECTRIC WATER COOLER W/ ALL RELATED PLUMBING IN LOCATION SHOWN ON FLOOR PLAN. THE USED ON THE INTERIOR OF THE DEMISED PREMISES. IT IS THE INTENT OF THESE GLIDING PRODUCT'S DOORS AND HARDWARE PRIOR TO INSTALLATION C. USE PLAIN OR PERFORATED JOINT TAPE COMPLYING WITH ASTM G MAXIMUM MOUNTING HEIGHT FOR THE SPRINKLING SPOUT IS 36' A.F.F. MINIMUM CLEARANCE BELOW THE WATER SPECIFICATIONS TO PROVIDE A COMPLETE NEW STORE LIGHTING SYSTEM THROUGH THE AND OBTAIN VERIFICATION FROM THE OWNER OF ALL FINAL COLORS 475, AND JOINT COMPOUND ADHESIVES WITH OR WITHOUT FILLERS COOLER IS 27' A.F.F. (SUPPLIED BY FDS). RETROFIT OF EXISTING INTERIOR FLUORESCENT LIGHT FIXTURES OR THE INSTALLATION AND FINISH MATERIALS. COMPLYING WITH ASTM 0475. PROVIDE PRE - MIXED, TWO- 8. INSTALL NEW 7.5 KW ELECTRIC UNIT HEATER IN RECIEVEING ROOM AT MAX 8' -0" A.F.F. OF NEW FIXTURES. ALL FIXTURES IN THE DEMISED PREMISED WILL BE OUTFITTED TO 12. THERE SHALL BE NO CHANGES TO OR DEVIATIONS FROM THE REQUIREMENTS COMPOUND TREATMENT; ONE FOR BEDDING AND ANOTHER FOR LOCATED UNIT 4' FROM REAR WALL AND 3' FROM EXTERIOR FREIGHT DOOR OPENING. UNIT SHOULD USE T -8 ENERGY EFFICIENT FLUORESCENT LAMPS WITH HIGH OUTPUT BALLAST'S. THIS OF THESE DRAWINGS UNLESS SUCH CHANGES OR DEVIATIONS ARE APPROVED JOINT FlNISIH TOPPING. FACE REAR DOOR. SUPPLIED BY FDS. PROGRAM DOES NOT ALLOW FOR ALTERNATE INSTALLATIONS. THE CONDITIONS OF . PURCHASE OF THESE FIXTURES SHALL BE DEFINED BY THE LEASE AGREEMENT AND THE 9. FURNISH AND INSTALL NEW MOP SINK IN LOCATION SHOWN ON FLOOR PLAN AND ALL RELATED PLUMBING I WRITING BY TENANT PRIOR TO THE WORK BEING DONE. D. INSTALL AND FINISH GYPSUM BOARD TO COMPLY WITH ASTM C 13. ALL WORK SHALL BE PERFORMED BY COMPETENT AND EXPERIENCED 840. INSTALL BOARDS ACROSS FRAMING IN A MANNER WHICH 10. REPLACE EXISTING THERMOSTATS WITH LIGHTSTAT THERMOSTATS MODEL #TME -CVS (CONTACT CONSTRUCTION CONTRACT. ALL NEW FIXTURES, LAMP AND BALLAST'S ARE TO BE MADE 800- 292 -2444 FOR INFO) MOUNTED 8' -0' A.F.F. SUPPLIED BY FDS. AVAILABLE THROUGH A NATIONAL ACCOUNT PROGRAM WHICH HAS BEEN ESTABLISHED WORKMEN AND EXECUTED IN A NEAT AND WORKMANLIKE MANNER. MINIMIZES OR AVOIDS COMPLETELY THE NUMBER OF END -BUTT FACE REAR DOOR. SUPPLIED BY FDS. TENANT. CONTRACT CHENEY DONS W/ GRAYBAR ELECTRIC AT 800 - 933 -9831 M. 2 - SITE WORK: ( NOT USED) JOINTS. STAGER VERTICAL JOINTS OVER DIFFERENT STUDS ON 10. FURNISH AND INSTALL A NEW 6 GAL. WATER HEATER WITH ALL RELATED PLUMBING AND ELECTRICAL WORK IN FAX 704 - 392 -4528 FOR INFORMATION REGARDING THIS PROGRAM. OPPOSITE SIDES OF PARTITIONS. INSTALL TRIM AND FINISH AS DIV. 3 - CONCRETE REQUIRED LOCATION SHOWN. INCLUDE DRAIN, OVERFLOW PAN AND DRAIN LINES AS REQUIRED BY CODES. 2. FURNISH AND INSTALL AND MAKE FINAL CONNECTION TO LIGHT FIXTURES TO 1. SAW CUT AS NEEDED FOR NEW PLUMBING INSTALLATION. E. ALL STEEL COLUMNS UNLESS SPECIFICALLY INDICATED, TO REMAIN EXPOSED. 11. FURNISH AND INSTALL DUCTWORK AND DIFFUSER(S) FOR AIR DISTRIBUTION TO TOILET ROOMS. PROVIDE A NEW SALES AREA LIGHTING SYSTEM IN ACCORDANCE WITH TENANT'S 2 REPAIR EXISTING FLOOR AS NEEDED TO PROVIDE A SMOOTH SURFACE READY FOR 4. ACOUSTICAL CEILING -NEW. PROVIDE AND INSTALL AS SHOWN. 12. PRIOR TO TURNOVER OF THE SPACE TO FOS, THE GENERAL CONTRACTOR WILL HAVE ALL OF THE SUPPLY AND LIGHTING PLAN CONSISTING OF TANDOM T -8 ENERGY EFFICIENT FLUORESCENT LIGHT FIXTURES IN NEW FINISH, OR AREAS THAT HAVE BEEN AFFECTED BY NEW PLUMBING INSTALLATIONS. RETURN GRILLES CLEANED FOR THE ENURE SPACE. 8' AND 4' LENGTHS. LIGHT FIXTURES, LAMPS AND BALLASTS 0 A 3. PROVIDE NEW PIPE BOLLARDS AS SHOWN ON FLOOR PLAN. PAINT 'SAFETY YELLOW PATCH EXISTING WHERE MODIFICATIONS TO F.P. RE MADE .P. . 13. IN EACH TOILET ROOM, FURNISH AND INSTALL TOILET EXHAUST FAN WITH VENT TO EXTERIOR. THROUGH NATIONAL ACCOUNT PROGRAM. 2, 4. FL PLAEW I�g�j P�D TRASH PAD AND ENCLOSURE AT REgEViNG DOOR AS NOTED ON A NON RATEDE WHITE, OTHERWISE 2' 0' X 4 0' 5 /B� THICK S FISSURED TILE 14. F AND INSTALL DUCTWORK AND DIFFUSER FOR AIR DISTRIBUTION TO MANAGER'S OFFICE. 3. FURNISH AND INSTALL AND MAKE FINAL CONNECTION TO LIGHT FIXTURES TO ADD N t'wt DE PLAN INDICATING ALL DUCT WORK CHANGES. RA F1 DIV. 4 - MASONRY: PROVIDE AND INSTALL AS SHOW ON A7_ WITH 1 WIDE DIRECT SUSPENSION T -GRID AND EDGE TRIM. A CONTINUOUS ROW OF TANDOM T -8 ENERGY EFFICIENT FLUORESCENT LIGHT FIXTURES IN 8' CEILING GRID TO BE INSTALLED AT 11' -6 A.F.F. 15. FURNISH AND INSTALL DUCTWORK AND DIFFUSER FOR AIR DISTRIBUTION TO RECIEVING ROOM. AND 4' LENGTHS TO PROVIDE PERIMETER LIGHTING IN SALES AREA AS SHOWN ON LIGHTING 1. 5 - MISC. METALS (NOT USED.. MINIMUM 3 SUPPLY LINES. PROVIDE PLAN INDICATING ALL DUCT WORK CHANGES. PLAN. PERIMETER LIGHTS SHOULD BE A MIN. OF 2' AND A MAX. OF 3' OFF ALL SALES AREA WAL LS. UNLESS OTHERWISE NOTED IN FINISH SCHEDULE. 1. PROVIDE TEMPORARY SHORING AND NEW STRUCTURAL BEAMS, ETC AS CALLED FOR 16. REPLACE AIR FILTERS, CLEAN AND STRAIGHTEN COILS IN EACH EXISTING AND NEW UNIT AT THE COMPLETION PROVIDE NEW LIGHT FIXTURES, LAMPS & BALLAST'S THROUGH A NATIONAL ACCOUNT FOR IN STRUCTURAL SHEETS. B. INSTALL SUSPENSION SYSTEM ACCORDING TO ASTM C 636, " DIV 6 - W000 do PLASTICS RECOMMENDED PRACTICE FOR INSTALLATION OF METAL CEILING COMPLETION OF CONSTRUCTION ' PRIOR TO FDS POSSESSION. PROGRAM. SEE ELECTRICAL NOTE #21. 17 1. PROVIDE BLOCKING, HAILERS, AND SIMILAR SUPPORT FOR SHELVING AND 17. ENSURE ALL UTILITIES ARE SEPARATELY METERED TO THE FDS DEMISED PREMISE. ., SUSPENSION SYSTEMS FOR ACOUSTICAL TILE AND LAY -IN PANELS.' 4. FURNISH AND INSTALL AND MAKE FINAL CONNECTION TO ONE 4' T -8 ENERGY E I USE MINIMUM 12 GAUGE HANGER WIRES. SPACE AS REQUIRED 18. PROVIDE NEW NATURAL GAS SERVICE EXCLUSIVELY SERVING THE DEMISED PREMISES INCLUDING SEPARATE METER. TO ALLOW ATTACHMENT OF OTHER WORK. USE FIRE TREATED WOOD OR EFFICIENT FLUORESCENT STRIP LIGHT FIXTURE CONTROLLED BY A WALL SWITCH IN PLYWOOD IN ANY CONCEALED SPACES OR WALLS. (MAXIMUM 4 FEET ON CENTER). PROVIDE DIAGONAL, CROSS -WIRE 19. PROVIDE GAS LINES FOR NEW OR EXISTING HVAC SYSTEM. SAID GAS LINE TO BE PRESSURE TESTED TO MEET MANAGER'S OFFICE AS SHOWN ON TENANT'S LIGHTING PLAN. PROVIDE 2. USE FINISHING NAILS FOR FINISH WORK AND COUNTER SINK NAIL HEADS BRACING IN ACCORDANCE WITH BUILDING CODE FOR SEISMIC CODE AND READY FOR METER BY LOCAL UTILITIES. NEW LIGHT FIXTURES, LAMPS AND BALLASTS THROUGH NATIONAL ACCOUNT ON EXPOSED MILLWORK AND CABINETRY. FILL HOLES AND FINISH SO AS BRACING. 20. TERMINATE ALL NATURAL GAS LINES TO THE SPACE ADJECENT TO THE DEMISED PREMISES PROGRAM. TO NOT BE VISIBLE. COMPLY WITH QUAUTY STANDARDS OF C. COORDINATE WITH MECHANICAL AND ELECTRICAL; CUT EDGES SO THAT THE EXISTING NATURAL GAS SERVICE WILL SERVE ONLY THE DEMISED PERMISES INCLUDING 5. FURNISH AND INSTALL AND MAKE FINAL CONNECTION TO ONE (1) 4' T -8 ENERGY ARCHITECTURAL WOODWORK INSTITUTE AND PS 20 'SOFTWOOD LUMBER AND OPENINGS NEAT AND CLEAN. MAINTAIN ALL UNITS CLEAN SEPARATE METER. LANDLORD SHALL BE RESPONSIBLE FOR PROVIDING SERVICE TO ADJACENT TENANTS EFFICIENT FLUORESCENT STRIP LIGHT FIXTURE CONTROLLED BY A WALL SWITCH IN EACH STANDARDS' AND NATIONAL HARDWOOD LUMBER ASSOCIATION RULES. AND UNDAMAGED. 21. TERMINATE ALL WATER SERVICE TO THE SPACE ADJECENT TO THE DEMISED PREMISES TOILET ROOM AS SHOWN ON TENANT'S LIGHTING PLAN. PROVIDE NEW 3. SET WORK TO REQUIRED LEVELS AND LINES WITH MEMBERS PLUMB AND 5 . FLOOR COVERINGS - PROVIDE AND INSTALL AS SHOWN ON PLANS. SO THAT THE EXISTING WATER SERVICE WILL SERVE ONLY THE DEMISED PERMISES INCLUDING LIGHT FIXTURES, LAMPS AND BALLASTS THROUGH NATIONAL ACCOUNT PROGRAM. No. Revision /Issue I Date TRUE TO LINE AND CUT AND FITTED. SCRIBE AND COPE AS REQUIRED. A. CLEAN, SEAL, WAX AND BUFF NEW VINYL FLOORING IN ACCORDANCE WITH SEPARATE METER. LANDLORD SHALL BE RESPONSIBLE FOR PROVIDING SERVICE TO ADJACENT TENANTS 6. FURNISH AND INSTALL AND MAKE FINAL CONNECTION TO TANDOM 8' T -8 ENERGY 4. PROVIDE SHELVING SUPPORT BRACKETS AND ASSOCIATED ACCESSORIES MANUFACTURER'S SPECIFICATIONS. EFFICIENT FLUORESCENT LIGHTING IN RECEIVING ROOM CONTROLLED BY A WALL SWITCH IN WHERE SHOWN. UTILITY SHELVING TO BE CONSTRUCTED FROM HIGH B. PROVIDE TRANSITION STRIPS AS NEEDED TO ASSURE SMOOTH TRANSITIONS. LOCATED NEXT TO DOOR LEADING TO SALES AREA AS SHOWN ON TENANT'S LIGHTING PLAN. Flrm Name and Address DENSITY PARTICLE BOARD WITH VINYL EDGE STRIP OR 3/4" GRADE A 6. WALL BASE - PROVIDE AND INSTALL AS SHOWN ON PLANS, INCLUDING INTERIOR COLUMNS. PROVIDE NEW LIGHT FIXTURES, LAMPS AND BALLASTS THROUGH NATIONAL ACCOUNT PROGRAM 7 PAINTING - PLYWOOD WITH VINYL EDGE , PROVIDE AND INSTALL AS SHOWN ON PLANS. ARCHITECTURAL SHELVING TO BE EITHER A PAINT PERIMETER WALLS T THE SALES FLOOR FROM 10' -6" A.F.F TO 11' -6' DIV. 16 - ELECTRICAL 7. FURNISH AND INSTALL AND MAKE FINAL CONNECTION TO ILLUMINATED EXIT SIGN(S) MARIDAD PLASTIC LAMINATE OR STAINED WOOD EDGED AS SHOWN ON DRAWINGS IN ACCORDANCE WITH ALL APPLICABLE CODES. PROVIDE NEW EXIT SIGNS 5. PROVIDE AND INSTALL ALL BASE CABINETS, WALL CABINETS, AND A.F.F. A STRIPE USING A MINIMUM OF 2 COATS OF SHERWIN WILUAMS 'SAFETY RED'- 1. FURNISH AND INSTALL WIRING AND HOOKUP FOR REFRIGERATED DRINK BOX. CIRCUIT TO INCLUDE FIXTURES, LAMPS AND BALLASTS THROUGH NATIONAL ACCOUNT PROGRAM. SUPPLIED BY FDS. COUNTER TOPS UNITS AS SHOWN. SAID STRIPE SHALL BE 12' HIGH - ONLY USE WHEN CEILING IS 13' -6' OR HIGHER. SHALL BE TERMINATED AT A JUNCTION BOX ABOVE SALES AREA CEILING WITH FINAL 6. CABINETS SHALL BE CUSTOM QUALITY, FLUSH PLASTIC LAMINATE B. PAINT WALLS FROM FLOOR TO CEILING; THE ENTIRE STOREFRONT WALL AND CONNECTION MADE TO SPECIAL PLUGGING 'PIGTAIL" CONNECTOR (SUPPLIED BY FDS). 8. PROVIDE AND INSTALL AND MAKE FINAL CONNECTION TO IN -UNE EMERGENCY 1074 E. 2100 S. FACED, WITH MELAMINE INTERIOR SURFACES AND ADJUSTABLE 20' -0' ON THE LEFT SIDE AND RIGHT SIDE WALL. PAINT AN AREA 4' WIDE FOS OPENING TEAM WILL INSTALL POWER POLE TO FINAL LOCATION BY ATTACHING TO LIGHT FIXTURES, CONSISTING OF SPECIAL 8' T -8 ENERGY EFFICIENT FLUORESCENT AROUND EACH DOOR AND IN EACH CORNER. PAINT ALL OTHER WALL SURFACES THIS CONNECTION. VERIFY EXACT LOCATION WITH TENANT'S CONSTRUCTION REPRESENTATIVE. FIXTURES IN ACCORDANCE WITH ALL APPLICABLE CODES. PROVIDE NEW SHELVES. HINGES TO BE CONCEALED EUROPEAN TYPE PULLS TO BE AL STAINLESS STEEL, ALUMINUM, OR STEEL WITH 26D FINISH. ABOVE W -10' IN HEIGHT TO BOTTOM OF CEILING. USE SHERWIN WILLIAMS SW#8003 2. FURNISH AND INSTALL WIRING AND HOOKUP FOR PROMOTIONAL OUTLET. CIRCUIT FIXTURES TO INCLUDE FIXTURES, LAMPS AND BALLASTS THROUGH NATION ACCOUNT PROGRAM. FURNISH AND INSTALL WALL PACK TYPE LIGHTS IF I LINE ARE NOT S LIT 84106 DIV. 7 - THERMAL PROTECTION - PICKET FENCE EGGSHELL LATEX ENAMEL SHALL BE TERMINATED AT A JUNCTION BOX ABOVE SALES AREA CEILING WITH FINAL PERMITTED IN ACCORDANCE WITH ALL APPLICABLE CODES. 1. PROVIDE SOUND ATTENUATION INSULATION IN WALLS SHOWN WHICH C. PAINT STRUCTURAL POLES /COLUMNS USING SHERWIN WILLIAMS SW#8003 CONNECTION MADE TO SPECIAL PLUGGING "PIGTAIL' CONNECTOR (SUPPLIED BY FDS). 9. FURNISH AND INSTALL WALL PACK TYPE EMERGENCY LIGHT IF IN -LINE LIGHTS ARE NOT PERMITTED INCLUDES DEMISING WALLS, RESTROOM WALLS, MATERIAL TO COMPLY - PICKET FENCE, SEMI -GLOSS ALKYD ENAMEL FDS OPENING TEAM WILL INSTALL POWER POLE TO FINAL LOCATION BY ATTACHING TO IN ACCORDANCE WITH ALL APPLICABLE CODES. WITH FS HH -1 -521, TYPE 1, SEMI -RIGID, CLASS 25 FLAME SPREAD, D. PAINT INTERIOR OF TOILET ROOM WALLS USING SHERWIN WILLIAMS SW#8003 THIS CONNECTION. VERIFY EXACT LOCATION WITH TENANT'S CONSTRUCTION REPRESENTATIVE. t0 FURNISH AND INSTALL UNDER CANOPY LIGHTING CONSISITING OF 8' 2 -TUBE F -40 T 8 STRIP Project Name and Address MINERAL FIBER BLANKET WITHOUT MEMBRANE - PICKET FENCE, SEMI -GLOSS ALKYD ENAMEL INCLUDE DOORS AND FRAMES INSIDE AND OA FURNISH AND INSTALL DUPLEX CONVENIENCE ELECTRICAL RECEPTACLE AND PHONE CONNECTION WITH LIGHT FIXTURES W/ 0 DEGREE BALLASTS IN A CONTINUOUS ROW, THE ENTIRE WIDTH OF THE 2. PATCH ANY EXISTING FIREPROOFING ON STRUCTURAL MEMBERS THAT ARE E. PAINT INTERIOR OF OFFICE WALLS USING SHERWIN WILUAMS SW#8003 HOME RUN TO PHONE BOARD FOR RECEIVING ROOM ADJACENT TO DOOR LEADING TO SALES FLOOR. DEMISED PREMISES ON A CIRCUIT WITH PHOTOCELL CONTROL. FAMILY DOLLAR DAMAGED DURING DEMOLITION, OR CONSTRUCTION PHASE OF WORK. - PICKET FENCE, EGGSHELL . VERIFY EXACT LOCATION WITH TENANT'S REPRESENTATIVE. 11. FURNISH AND INSTALL 175 WATT METAL HALIDE VAPOR (REAR OF BUILDING AT RECEIVING DOOR) 36 CAULK GAPS /OPENINGS BETWEEN DISSIMILAR MATERIALS AS REQUIRED. F. STAIN ALL WOOD DOORS MEDIUM WALNUT, PAINT ALL METAL DOORS SHERWIN WILLIAMS 4. FURNISH AND INSTALL WIRING AND HOOKUP FOR EACH CASHIER'S MODULE INCLUDING; EXTERIOR WALL PACK(S) WITH SHATTERPROOF LENS WIRED TO PHOTOCELL CONTROLS STORES TENANT'S CONSTRUC110N REPRESENTATIVE SHALL DETERMINE QUANTITY AND LOCATION .SUPPLIED BY FDS. � DIV. 8 - DOORS & WINDOWS - SW0003 PICKET FENCE, SEMI GLOSS CONVENIENCE CIRCUIT, DEDICATED CIRCUIT WITH ISOLATED GROUND AND PHONE CONNECTION. 12 FURNISH AND INSTALL 250 WATT METAL HALIDE VAPOR (REAR OF DEMISED PREMISES) EXTERIOR WALL PACK(S) WITH 1. PROVIDE METAL FRAMES OF MINIMUM 16 GAUGE, COLD - ROLLED G. PAINT INTERIOR RECEIVING ROOM CEILING USING SHERWIN WILLIAMS - SW#8003, CIRCUITS SHALL BE TERMINATED AT A JLJNC11ON BOX ABOVE THE CEILING WITH FINAL SHATTERPROOF LENS WIRED TO PHOTOSTAT CONTROLS. TENANTS CONSTRUCTION REPRESENTATIVE SHALL REXBURG FURNITURE STEEL WITH MITERED CORNERS, WELDED CONSTRUCTION 'PICKET FENCE' SEMI- GLOSS. CONNECTION MADE TO SPECIAL PLUGGING "PIGTAIL" CONNECTORS (SUPPLIED BY FDS). DETERMINE QUANTITY AND LOCATION OF THE SECURITY LIGHTS. SUPPLIED BY FDS. ir FOR ALL DOOR FRAMES UNLESS SPECIFICALLY NOTED OTHERWISE. H. PAINT CORNER OF CURB YELLOW ALONG FDS STOREFRONT WIDTH OF THE STORE. FDS OPENING TEAM WILL INSTALL POWER POLES TO FINAL CHECKOUT LOCATIONS BY 13 FURNISH AND INSTALL 1000 WATT METAL HALIDE VAPOR EXTERIOR WALL PACK(S) REPRESENTATIVE SHALL DETERMINE QUANTITY AND LOCATION OF . I D ATTACHING TO THESE CONNECTIONS. TWO PHONE CONNEC1IONS ARE REQUIRED WITH WITH SHATTERPROOF LENS WIRED TO PHOTOSTAT CONTROLS. 'S COMPLY WITH SDI -100 RECOMMENDED SPECIFICATIONS FOR STANDARD INDEPENDANT HOME RUNS TO PHONE BOARD VERIFY EXACT LOCATION OF EACH REPRESE STEEL DOORS AND FRAMES.' INSTALL IN COMPLIANCE WITH PROVISIONS TENANT CONSTRUCTION THE SECURITY LIGHTS. SUPPLIED BY FDS. OF SDI -105 'RECOMMENDED ERECTION INSTRUCTIONS FOR STEEL DIV. 10 - SPECIALTIES REQUIRED DROP WITH TENANT'S CONSTRUCTION REPRESENTATIVE. DIV. 17- MISCELLANEOUS FRAMES.' INSTALL AT LEAST THREE WALL ANCHORS PER JAMB AT HINGE 1. FIRE EXTINGUISHER(S) - PROVIDE UL RATED, 4 -A: 6 -B: C, MULTI- PURPOSE 5. FURNISH AND INSTALL FLUSH MOUNTED DUPLEX CONVENIENCE ELECTRICAL RECEPTACLE Project sheet �_� O AND STRIKE LEVELS. DRY CHEMICAL, 10 POUND CAPACITY, UNITS IN ENAMEL STEEL IN CEILING AT STOREFRONT GLASS OVER ENTRANCE DOOR. 1. PRESSURE WASH STOREFRONT AND SIDEWALK IN DEMISED PREMISES FRONT AFTER CONSTRUCTION COMPLETION SPEC � S 3. INSTALL FRAMES PLUMB AND LEVEL ALIGN AND FIT DOORS IN FRAMES & 2. MACHINE DOORS FOR HARDWARE SEAL CUT SURFACES AFTER FITTING. CONTAINER WHERE SHOWN ON PLANS. PROVIDE MOUNTING BRACKETS. REMOVE ALL FOREIGN DEBRIS AND GUM. DIV. 11 - 14 - EQUIPMENT. FURNISHINGS SPECIAL CONSTRUCTION 6. FURNISH AND INSTALL WIRING AND HOOKUP FOR (1) DEDICATED CIRCUIT WITH ISOLATED 2 GENERAL CONTRACTOR SHALL PERFORM ANY /ALL WORK REQUIRED TO CAUSE THE ENTIRE DEMISED gate 1/20/05 SHEET WITH UNIFORM 1/8' CLEARANCES AND 1/8' IN 2' BEVELS, EXCEPT CONVEYING SYSTEMS: GROUND ABOVE CEILING AT STOREFRONT DOORS FOR FUTURE SECURITY SYSTEM. PREMISES TO COMPLY WITH LAWS PERTAINING TO ACCESSIBILITY BY DISABLED PERSONS (ADA) AND WILL OBTAIN AND COMPLY WITH NFPA 80 FOR CLEARANCES AND BEVELS ON FIRE -RATED 1. NOT USED: INSTALL FDS SUPPLIED ROLLER RACKS & RACK HOLDER. LOCATION TO BE DETERMINED CIRCUIT SHALL BE TERMINATED AT A JUNCTION BOX ABOVE SALES AREA CEILING WITH INSTALL A CERTIFICATE OF OCCUPANCY AND HEALTH CERTIFICATE (IF REQUIRED). CERTIFICATE ASSEMBLIES. BY TENANT SHALL BE INSTALLED IN AN 8 -1/2' X 11' FRAME ON THE OUTSIDE OF THE OFFICE WALL IN A CONSPICUOUS Scale LOCATION CONSTRUCTION REP. FINAL CONNECTION MADE TO SPECIAL PLUGGING GREEN 'PIGTAIL' CONNECTOR. FDS OPENING LOCATION. THIS SHALL BE CONCLUDED PRIOR TO DELIVERING THE DEMISED PREMISES TO TENANT. � /5��= ��•��� 4. INSTALL 6' WIDE x 7' HIGH EUASON HI IMPACT DOUBLE SWING DOORS DIV. 15 - HVAC & PLUMBING, TEAM WILL INSTALL POWER POLE TO FINAL LOCATION BY ATTACHING TO THIS AO , 1 (MODEL #LIP -3) LOCATED AS SHOWN ON FLOOR PLAN. 1. MECHANICAL AND PLUMBING WORK IS TO BE INSTALLED AS SHOWN ON THESE PLANS CONNECTOR. VERIFY EXACT LOCATION WITH TENANT'S CONSTRUCTION REPRESENTATIVE. 7. PROVIDE FOR ONE VAN ACCESSIBLE PARKING SPACE IN CLOSE PROXIMITY TO THE ACCESSIBLE E PLACE ON A LOCKING BREAKER. PATH TO THE DEMISED PREMISES BY PAINTING ONE PARKING SPACE AS DISABILITY PARKING LIASON CORPORATION - 1- 800 - 828 -3655 (PROVIDED BY FDS} AND THE INFORMATION GIVEN IN THESE CONSTRUCTION DOCUMENT'S. 7. FURNISH AND INSTALL TWO WEATHERPROOF EXTERIOR OUTLETS AT STOREFRONT. (8' WIDE MINIMUM) AND PAINTING ONE 8' WIDE ACCESS ISLE DIRECTLY ADJACENT TO THIS SPACE. 2. FURNISH AND INSTALL ALL NEW FIXTURES TO TOILET ROOMS IN LOCATIONS SHOWN ON PLAN • • • GENERAL NOTES: REMOVE ALL LIGHT FIXTURES THROUGHOUT DEMISED PREMISES IN PREPARATION FOR NEW LIGHT FIXTURES AS SPECIFIED IN ELECTRICAL DRAWINGS AND REFLECTED CEILING PLAN. .� a• « CAP OFF ALL PLUMBING LINES, WHICH ARE NOT TO BE REUSED, MAKE FLUSH WITH ADJACENT SURFACES. REMOVE EXISTING COLUMN COVERS. CAP OFF OR TERMINATE ALL ELECTRICAL DISTRIBUTION LINES, WHICH ARE NOT TO REUSED, FLUSH WITH ADJACENT SURFACES. REMOVE EXISTING TOILET ROOMS SHOWN ON THE FLOOR PLAN AND STUB OFF ALL PLUMBING. PATCH HOLES IN FLOOR SLAB WITH CONCRETE LEAVING A SMOOTH, LEVEL FLOOR. REPAIR FLOOR COVERING TO MATCH SURROUNDING FINISH. REMOVE EXCESS PHONE EQUIPMENT AND RELATED WIRING. REMOVE MEZZANINE AND STAIRWAY TO MEZZANINE. REMOVE FREIGHT ELEVATOR AND ASSOCIATED COMPONENTS. 1 %' EMOVE ELEVATED PLATFOR 1OCK DOOR • • , • , • ' REMOVE ALL ASBESTOS CONTAINING MATERIALS AS REQUIRED BY CODE. PROVIDE TO FAMILY DOLLAR A CLOSURE LETTER STATING THAT TO TEH BEST OF YOUR KNOWLEDGE THE SPACE IS FREE OF ASBESTOS. DEMO EXISTING HVAC IN EXISTING DEMISED PREMISES. No. I Revision /Issue I Date Firm Name and Address MARIDADI 1 074 II S. AN111119f R Project Name and Address n ' FAMILY DOLLAR r �Num ■ 1 1rr r r r r , DEMO PLAN loll IN SCALE: 1/8! = 1' -0' *Contractor to provide project manager weekly progress photos by noon on Mondays. Project Sheet C -10 DEMO PLAN Date 1 /20/05 Scale Al § 0 1/8" =1' -0" Ar x f KEYED NOTES: 0 PROVIDE AND INSTALL NEW FIRE EXTINGUISHER. SEE SPECIFICATIONS. ❑2 PROVIDE AND INSTALL FROM FINISHED WALL TO FINISHED WALL 26" DEEP LAMINATED COUNTER TOP W/ BACKSPLASH AND BULLNOSE FRONT. CLEAR UNDERCOUNTER HEIGHT TO BE 30" A.F.F. INCLUDE 12" DEEP WOOD SHELF 060" A.F.F. WITH CENTER SUPPORT. LAMINATE COLOR WHITE. SEE SECTION 1 THIS SHEET. INSTALL MONITOR BRACKET PROVIDED BY FDS AS PER THE LOCATION ON THE FlXUNRE PLAN. SAID MOUNTING SHALL MEET ALL STATE AND LOCAL CODES. ® PROVIDE AND INSTALL 4' X 6' PREFABRICATED METAL CANOPY OVER EXTERIOR FREIGHT RECEEVING DOOR. PROVIDE AND INSTALL 8'X 4'X 3/4" CDX COMMUNICATION BOARD FOR USE BY DEMARC CONNECTION AND OUTSIDE INSTALLER. MOUNT AND SECURE BOTTOM OF BOARD AT 30" OF A.F.F. BOARD SHOULD BE ABLE TO CARRY A MIN OF 225 LBS. SEE PLANS FOR EXACT LOCATION. Q PROVIDE BLOCKING IN WALLS FOR ELECTRIC HAND DRYER AND SHELVING IN RESTROOMS. COORDINATE EXACT LOCATION WITH PROJECT MANAGER. - INSTALL 4'H FRP TO WALL WHERE WATER COOLER AND MOP SINK ARE LOCATED. g� WELD SHUT AND CAULK EXTERIOR DOORS WHICH ARE NOT TO BE USED AS SHOWN ON BOOR PLAN. REMOVE EXTERIOR DOOR AS SHOWN ON BOOR PLAN AND INFlLL WITH BLOCK AND PAINT EXTERIOR TO MATCH BUILDING. PROVIDE AND INSTALL, TWO (2) MINUMUM 3' -0" DEEP, 7'-0' LONG PIPE BOLLARD AT CORNERS OF PAD, FILLED WITH CONCRETE TO TOP, PAINT 'SAFETY RED SEMI GLOSS'. COORDINATE LOCATION OF BOLLARDS WITH PROJECT MANAGER. TYPICAL RESTRM ELEV. 1/8" = 1' -0' YPICAL RESTRM PLAN IAr = 1 12' D WOOD SHELF 60' A.F.F. 601 2if " • »� �� • • « .• US TYPICAL WORKSURFACE I is= f—V 1 PROVIDE AND INSTALL 6" THICK 6'X10' CONCRETE PAD AT EXTERIOR FREIGHT RECEIVING DOOR. PROVIDE AND INSTALL, TWO (2) MINUMUM 3' -0" DEEP, 7' -0" LONG PIPE BOLLARD AT CORNERS OF DUMPSTER, FILLED WITH CONCRETE TO TOP, PAINT 'SAFETY RED'. COORDINATE LOCATION OF BOLLARDS WITH PROJECT MANAGER. i® PROVIDE AND INSTALL 6" THICK X 12' X 32' CONCRETE DUMPSTER PAD AT LOCATION SHOWN ON EXHIBIT B— SITE PLAN. PROVIDE AND INSTALL, TWO (2) MINUMUM 3' -0' DEEP, 7' -0" LONG PIPE BOLLARD AT CORNERS OF PAD, FILLED WITH CONCRETE TO TOP, PAINT 'SAFETY RED'. INCLUDE NECESSARY FENCING OR WALLS AND GATES AS DETAILED ON SHEET A6.0. PAINT EXISTING PIPE BOLLARDS 'SAFETY RED'. WALL TYPES: A IN SALES AREA AND MANAGER'S OFFICE AS NEEDED FOR NEW FINISH. BELOW 6'8" MAY BE UNREPAIRED & UNPAINTED GYP. BD. IN LOCA11ONS WHERE FIXTURES ARE TO BE PLACED. FURR FOR FLUSH FINISH WITH NO PROJECTION. EXISTING STUD & GYP. BD. WALL REPAIR GYP. BD. IN B SALES AREA AS NEEDED FOR NEW FINISH. BELOW 6'8' MAY BE UNREPAIRED & UNPAINTED GYP. BD. IN LOCATIONS WHERE FIXTURES ARE TO BE PLACED. FURR FOR FLUSH FINISH W/ NO PROJECTION. EXTEND WALL TO ROOF DECK. SAID WALL TO BE AIRTIGHT. EXISTING STOREFRONT /(LASS /CMU/BRICK WALL: APPLY GYP. BD. ON HAT CHANNEL AS NEEDED FOR NEW FINISH. BELOW 6'8" MAY BE UNREPAIRED & UNPAINTED GYP. BD. IN LOCATIONS WHERE FIXTURES ARE TO BE PLACED. FURR FOR FLUSH FINISH W/ NO PROJECTION. General Notes FOR BIDDING PURPOSES THE CONTRACTOR SHALL VISIT THE TENANT SPACE TO VERIFY THE EXISTING CONDITIONS BEFORE SUBMITTING BID. CONTACT PROJECT MANAGER AT FAMILY DOLLAR STORES WITH QUESTIONS PERTAINING TO THIS BUILD —OUT. EVERYTHING DRAWN LIGHTLY ON THE PLANS IS EXISTING. SEE DETAIL B,B.1 /A6.0 FOR THE BRACING OF THE WALLS. ALL DIMENSIONS FOR THE NEW WALLS ARE DIMENSIONED FROM THE FINISHED FACE OF A NEW WALL AND FROM THE FACE OF AN EXISTING WALL CONTACT DESIGNER IF ANY CONFLICTS IN THE PLANS ARE FOUND. PROVIDE INSULATION IN NEW WALLS OF RESTROOMS. PATCH AND REPAIR ALL EXISTING WALL FINISHES TO RECEIVE NEW FINISH. No. I Revision /Issue I Date Firm Name and Address MARIDADI 1074 E. 2100 S. SLC, UT 84106 Project Name and Address O NOT USED: NEW STORffRONT /IXASS /CMU WALL: MATCH � FAMILY DOLLAR 2 EXISTING GLAZING AND WALL PROPERTIES. APPLY GYP. � STORES BD. ON HAT CHANNEL AS NEEDED FOR NEW FINISH. • BELOW 6'8' MAY BE UNREPAIRED do UNPAINTED GYP. BD. Ir FLOOR PLAN � �►� � ����� w %� ���n PLACED. REXBURG ID BE AIRTIGHT. SCALE: 1/8" = 1' -0" T "Contractor to provide project manager weekly progress photos by noon on Mondays. 3 NEW WALL- 5/8" TYPE "X' GYPSUM BOARD ON BOTH SIDES OF 3-5/8" METAL STUDS AT 16' O.C. WALL CONTINUES TO THE UNDERSIDE OF DECK. WALL TO BE THREE HOUR RATED WHERE INDICATED. 4 NEW WALL: 5/8" TYPE 'X' GYPSUM BOARD ON BOTH SIDES OF 3-5/8' METAL STUDS AT 24" O.C. WALL TO EXTEND TO 8' -0" A.F.F. PROVIDE 314" PLYWOOD DECK ON 6" METAL JOISTS WITH GYPSUM BOARD OILING. Project Sheet C -10 FLOOR PLAN Date 1/20/05 Scale 1/8 " =1' -0" A2 1 General Notes 3" MAX TO TOP OF 3RD. TURN OF WIRE 12 GA. GALV. WIRE, 2 LOOPS MIN. AROUND SUPPORT, MIN. 4 TURNS 1 1/4 COLD ROLLED CHANNEL AT 4' -0" O.C. (2) REQUIRED AT SPANS GREATER THAN 4' -0" `-yQ� GA. GALV. HANGER WIRE AT 4 —0 O.C. NOT TO EXCEED SPREADER BAR WHERE REQUIRED 1:6 OUT OF PLUMB UNLESS BETWEEN TRUSSES COUNTERSLOPING WIRE IS INSTALLED / A 8 OR LE 3 TIGHT TURNS 1 1/2" MAX. EA. END, TYPICAL —CROSS MEMBER 2' POP RIVET 2 ADJACENT SIDES ONLY ANCHOR PERIMETER CLOSURE TO STRUCTURAL p ELEMENT 8' OR LESS BERC CUP /4• STRUT STABILIZER OR SIMILAR DEVICE 2' ATTACH TO DEC(, TRUSS, OR SPREADER BAR BETWEEN TRUSSES 0 �o �.... -- 1 1/2" METAL STUD AT 12' -0 O.C. 12 GA. SPLAY WIRE 0 12' -0' O.C. IN PLANE OF EA. RUNNER SCREW STUD TO VAX RUNNER OR) CROSS RUNNER MAIN RUNNER 2' 8' OR LESS 1. PERIMETER HANGERS: TERMINAL ENDS OF EACH CROSS RUNNER AND MAIN RUNNER SHALL BE SUPPORTED AT 8" MAX FROM EACH WALL WITH 12 GA. GALV. WIRE OR APPROVED WALL SUPPORT. 2. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH IBC 16- 21.2.5 3. ATTACH LIGHT FIXTURES ACCORDING TO DUTY OF SYSTEM INSTALLED & IBC 16- 21.2.5 4. AREAS SMALLER THAN 144 SO. FT. AND WITH WALLS ON FOUR SIDES EXTENDING TO THE STRUCT. AND BRACED INDEPENDENTLY OF CEILING AT TOP AND BOTTOM NEED NOT BE SEISMICALLY BRACED. 5. VERTICAL RESTRAINT MAY BE 3/4 EMT, 1 1/2 METAL STUD (SHOWN) OR OTHER SUITABLE MATERIAL FIRMLY ATTACH TO STRUCTURE OR DECK ABOVE AND TO CEILING MAIN RUNNER. �• r SEE ELECTRICAL SPECIFICATIONS FOR ALL ELECTRICAL WORK UNDER THIS CONTRACT. THE TENANT HAS A NATIONAL ACCOUNT FOR THE PROVISION OF LIGHT FIXTURES TO BE USED ON THE INTERIOR OF THE DEMISED PREMISES. IT IS THE INTENT OF THESE SPECIFICATIONS TO PROVIDE A COMPLETE NEW STORE UGH11NG SYSTEM THROUGH NEW INTERIOR FLUORESCENT LIGHT FIXTURES OR THE INSTALLA11ON OF NEW FIXTURES. ALL FIXTURES IN THE DEMISED PREMISES WILL BE OUTFITTED TO USE TANDOM T -8 ENERGY EFFICIENT FLUORESCENT LAMPS WITH HIGH OUTPUT BALLASTS. THIS PROGRAM DOES NOT ALLOW FOR ALTERNATE INSTALLATIONS. THE COND111ONS OF PURCHASE OF THESE FIXTURES SHALL BE DEFINED BY THE LEASE AGREEMENT AND THE CONTRUCTION CONTRACT. ALL NEW FIXTURES, LAMPS AND BALLASTS ARE TO BE MADE AVAILABLE THROUGH A NATIONAL ACCOUNT PROGRAM WHICH HAS BEEN ESTABLISHED BY TENANT. CONTACT TENANT'S LIGHTING COORDINATOR AT 704 - 814 -3519 FOR INFORMATION REGARDING THIS PROGRAM. PROVIDE AND INSTALL COMPLETE NEW SUSPENDED GRID CEILING WITH 2' X 4' TILES THROUGHTOUT THE SALES AREA AT 11' -6' ABOVE FINISHED FLOOR. WHERE CODE REQUIRED, PROVIDE FIRE RATED CEILING TILES WITH ALL NECESSARY MOUNTING AND HOLD DOWN CUPS. 1 _ 'qq 0 kkI 6 No. I Revision /Issue I Date Firm Name and Address MARIDADI 1074 E. 2100 S. SLC, UT 84106 Project Name and Address Project Sheet C -10 REFLECTED °°te 1/20/05 CEILING Scale 1/8" =1' -0" . (4) 12 GA. GALV. WIRE LATERAL BRACE AT 12' -0 O.C. EA. DIRECTION do 6' -0 MAX. FROM EACH WALL ALL WIRES TO BE 6' CLEAR —MAIN FROM ANY PIPE OR DUCT TYPICAL Z 8' OR LESS POP RIVET 2 ADJACENT SIDES ONLY C -4 � STRUT STABILIZER OR SIMILAR DEVICE FAMILY DOLLAR .� STORES Ir REXBURG, ID SCALE: 1/8" = 1' -0' NOTE PROVIDE LIGHT DUTY CLASSIFIED SYSTEM, CATEGORY D. INSTALL TO CISCA RECOMMENDATIONS CROSS TEES CAPABLE OF CARRYING OF REQUIRED LOAD WITHOUT EXCEEDING DEFLECTION LIMIT DOOR NOTES: 1. IF ( —) IS IN SLOT THEN NO ITEMS APPLY. 2. DOOR TYPES: __ _ SOLID CORE PRE — FINISHED R OR HM A 3'X7'DOOR 6'X7'DOOR 3. THICKNESS: THICKNESS IS 1 -3/4' UNLESS NOTED OTHERWISE 4. CONSTRUCTION/FINISH: S STEEL DO C OR, E N PRE — FINIS H ED. E E ECS. SPECS. HM= HOLLOW METAL, PAINTED. SEE SPEC'S. AL =CLEAR ANODIZED ALUMINUM 5. GLASS: T= TEMPERED 6. RATING: 20, 1, ETC. INDICATES FIRE RATING. 7. HM = HOLLOW METAL FRAME, PAINTED S =STEEL FRAME, PAINTED 8. NUMBER INDICATES DETAILS SHOWN ON THIS SHEET 9. NUMBER INDICATES HARDWARE GROUP. SEE SPECS. ALL DOOR HARDWARE TO COMPLY WITH ANSI A117.1 1998. NOTE FOR ADA: INTERIOR DOORS NOT TO EXCEED 5 LB MAX, EXTERIOR DOORS NOT TO EXCEED 10 -15 LB OPENING FORCE PRESSURE MAX. GROUP 1: 1 1/2 — PAIR —BUTTS HAGAR 1129 4 1/2 X 4 1/2 USP 1 — PANIC SCHLAGE CYLINDER 20 -02 /1US 26D 3 — SILENCER GROUP 2: 1 1/2 — PAIR —BUTTS HAGAR 1129 4 1/2' X 4 1/2' USP 1 — PRIVACY SCHL.AGE A40S —LEV -626 1 — STOP 3 — SILENCER 1 — CLOSER YALE 4020, PAINTED GROUP 4: 1 1/2 — PAIR —BUTTS HAGAR 1129 4 1/2' X 4 1/2' USP 1 — STORE ROOM FUNCTION LEVER TYPE LOCKSET SCHLAGE S80PD —LEV 626 1 — CLOSER YALE 4020, PAINTED 6' -0'X 7' -0' HEAD DETAIL - TYPICAL 3" = 1 -0" 5/8" GYPSUM BOARD OR CMU WALL 3 -5/8" METAL STUDS SEALANT BOTH SIDES HM OR STEEL DOOR FRAME 5/8" GYPSUM BOARD OR CMU WALL 3 -5/8" METAL STUDS *VERIFY THICKNESS OF WALL SEALANT BOTH SIDES JAMB DETAIL - TYPICAL 3 1: _ V-019 GROUP 2A: 1 1/2 — PAIR —BUTTS HAGAR 1129 4 1l2" X 4 1/2" USP 1 — PASSAGE SCHLAGE A10S —LEV -6266 1 — STOP 3 — SILENCER 1 — CLOSER YALE 4020, PAINTED GROUP 3: 1 1/2 — PAIR —BUTTS 1 — LOCKSET SCHLAGE A10S —LEV -626 1 — STOP 1 — CLOSER YALE 4020, PAINTED 3 — SILENCER GROUP 5: BY MANUFACTURER 10. KEYNOTES. 1. 6' X 7' EUASON HIGH IMPACT DOUBLE SWING DOOR (MODEL LWP -3 EASY SWING) EUASON CORPORATION 1- 800 -828 -3655 (SUPPLIED BY FDS, INSTALLED BY CONTRACTOR) 2. THIS DOOR TO HAVE KEYED DEADBOLT. PROVIDE LOCK GUARD DOOR UNDERCUT 1' . 3. 3' -0' X 7' -0' EXIST DOOR, INSTALL ARM A DOOR RPA (W) SECURITY BAR AND ALARM, (SUPPLIED BY FDS). DOOR CLOSER AND PEMKO WEATHERSTRIPPING J 303ASW /S3 INSTALL SIGN ON DOOR ' EMERGENCY EXIT ONLY'. PROVIDE DOOR SWEEP. NO EXTERIOR KNOBS OR HANDLES. CONTACT POSTIVE LOCK ® 1 -800 -342 -7670 4. INSTALL SIGN OVER DOOR: 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED' 5. PROVIDE NEW DOOR CLOSERS WITH KAWNEER 'HUSKY II' W. 105 DEGREE HOLD OPEN 6. REPLACE ALL CRACKED AND BROKEN GLASS WITH GLASS OF EQUAL SPECIFICATION OR TEMPERED. AS REQUIRED BY CODE 7. CLEAN AND REPLACE AS NECESSARY ALL INTERIOR AND EXTERIOR STOREFRONT ALUMINUM AND GLASS FOR UNIFORM APPEARANCE. REMOVE ALL TAPE, DECALS, AND OTHER ITEMS ATTACHED TO THE GLASS OR MULLIONS. 8. 4' -0' X 7' -0' NEW DOOR, INSTALL ARM A DOOR #A1OX —XXX (W) SECURITY BAR AND ALARM, (SUPPLIED BY FDS). DOOR CLOSER AND PEMKO WEATHERSTRIPPING # 303ASW /S3 PROVIDE DOOR SWEEP. NO EXTERIOR KNOBS OR HANDLES. CONTACT POSTIVE LOCK ® 1- 800 - 342 -7670 9. PROVIDE 180 DEGREE PEEP —SITE 0 5' -0' A.F.F. IN RECEIVING ROOM DOOR. 10. NOT USED: 3' -0" X 7' -0' NEW DOOR, INSTALL POSITIVE LOCK #THPA (W) SECURITY BAR AND ALARM, (SUPPLIED BY FDS). DOOR CLOSER AND PEMKO WEATHERSTRIPPING # 303ASW /83 INSTALL SIGN ON DOOR ' EMERGENCY EXIT ONLY'. NO EXTERIOR KNOBS OR HANDLES. 11. NOT USED: PROVIDE ONE WAY 12 W X 18 H LAMINATED GLASS WINDOW AT 4' -9' A.F.F IN DOOR. 12. PROVIDE CRASH BARS ON INTERIOR AND EXTERIOR OF NEW DOORS SUSP = 1' -0 an CLOSETS 54' ew 1/8" METAL STUD BRACE ENDS & APPROX. 8' -0' O.C. 'ACH TO TOP TRACK OF WALL 3 5/8' METAL STUDS AT 16" O.C. 5/8" GYP. BD. EACH SIDE uv O Q z U � z Q �z ` I �M ES I DO NOT FASTEN SHEATHING TO TRACK I Z EX. ROOF DECK 2x2x16 go. L 5/8' TYPE 'X' GYP. BD. EA. SIDE 1 1/2' 16GA U CHANNEL BRIDGING (2) St TO EA (S II�ED OPNG. W/ 1 1/20 1/2x16 GA CUP ANGLE W/ (2) SCREWS TO EA STUD METAL STUDS WALL BRACE WALL BRACE 1 1/2 = 1' -0" 131 1 1/2" = 1' -0" FK CUM _ - PMM GYPSUM WMiD - SEE FM 30111M • �� WALL SURFACE 0 32 Ok 4' -0' 11MM. &W -SEE FM SCHFDI!<E 20'-0" STANDARD FINISH ELEVATION 1 /8' = 1' -0' AMERICAN STANDARD, 0321.026.20, WHITE OR EQ. AMERICAN STANDARD, 2096.016.20 WHITE OR EQ. NOTE: PLUMBING FIXTURES & ACCESSORIES TO COMPLY WITH ANSI 117.1 1998 PRO" STOP M CaNTRDI. SMIG DMlECM & MANUFACTURERS' sfinew WEI►1HERST�PPINc KAUM 0 190' NAM N ST1fLE DR JAM B SCALE: 1 1/2" = 1' -0" o�_ L 1 Vii: � �. ���• PROVIDE STOP M CMMML SWIG DMIECM & MMUFACRIFIM STANDARD WANStSTRIPPMIG ( F NOT EXIS1NriG) KAUM 8 190' NARROW S A E � A DOOR OR EQW HE AD SCALE: 1 1/2" = 1' -0" EX WALL PIRM MW DMC N & " STANDARD MMUSIRMM KAWM • 190" NARROW SrAE DWIM AVII011 DOOR OR JAMB 3 SCALE: 1 1/2 = 1' -0" i••.. ... • y .i . . .. IU1W>r>EE t • 190' NARROW SME DWIM =1011 DOOR OR APPROUET) EQUAL ALUMON 1HRES W ANCHOR TO SLAB W M ENPANSION SEW SET M CAULM EACH SIX - 1112• HO MAX - HAHaCNME SILL SCALE: 1 1/2 = 1' -0" General Notes �x No. Revision /Issue I Finn Name and Address MARIDADI 1074 E. 2100 S. SLC, LIT 84106 Project Name and Address FAMILY DOLLAR STORES Ir REXBURG, ID Project Sheet C -10 SCHEDULES Date 1/20/05 Scale 1/8 A4 9 0 sees sun • FME IM MOSTAT • 0(1N6Ilm EtEVAIOR CJW. gunm ! CI181ET5 MWJK ML FME STATION • — ❑ Sw _GlE10014UTA STANDAR MIA" FBAWIE NAPIONS � O Z N .7f�Gl _ �� • zz g 9s o� PLUMBING FIXTURE SCHEDULE FIXTURE SINK TOILET MISC MANUFACTURER *VERIFY THICKNESS OF WALL AL FINISH SCHEDULE 0 0 a:: Z Q Q ~ WNN = B Of � CC O 3 U = w rN E S W w �'-- 100 SALES AREA 1 1 1 1 1 2 — 1 101 MANAGER'S OFFICE 1 1 1 1 1 1 8' —0' 1 102 WOMENS 3 2 1 1 2 1 8' —0" 1 103 MENS 3 2 2 1 1 11 8' —0" 1 104 RECEIVING 1 1 1 1 1 3 — 1 FINISH MATERIALS CHART FLOOR /BASE WALLS /WAINSCOT CEILINGS 1 12' X 12' VCT AND 4" VINYL COVE BASE, EXIST 1 PAINT, REFER TO SPECIFICATIONS 1 GYPSUM BOARD 2 CONCRETE 2 PAINT (REFER TO SPECIFICATIONS), 4' FRP 2 2 X 4 ACCOUS11CA I BOARD 3 SHEET VINYL WITH 6" COVED SHEET VINYL BASE 3 EXPOSED, EXISTING FINISH NOTES 1 CLEAN, STRIP, SEAL, WAX AND BUFF ALL FLOOR TILE IN SALES AREA, MANAGERS OFFICE, AND RESTROOMS.. ACCORDING TO TILE MANUFACTURER'S SPECIFICATIONS. ENSURE SMOOTH SUBFLOOR IS PROVIDED 2 CLEAN, SEAL, WAX AND BUFF ALL FLOOR TILE IN SALES AREA, MANAGERS OFFICE AND RESTROOMS. PROVIDE MATCHING TILE SAMPLE FOR APPROVAL TO THE FDS PROJECT MANAGER. CLEAN, STRIP, SEAL, WAX AND BUFF ENTIRE FLOOR. 3 *CLEAN & SEAL RECEIVING ROOM FLOOR (EXISTING CONCRETE) W/ CLEAR ACRYLIC SEALER LIST OF MATERIALS VINYL COMPOSITION TILE, ARMSTRONG 151809— STERLING OR MANNINGTON, TARKETT, IDROK 4' COVED VINYL BASE, JOHNSONITE, OR EQ., BLACK ON ALL WALLS THAT RECEIVE PAINT, & COLUMNS. REFER TO SPECS. CAULK AROUND EACH COLUMN ON SALES FLOOR. SHEET VINYL, ARMSTRONG, MANNINGTON, METAL EDGE AT TOP OF COVED BASE HEAD DETAIL - TYPICAL 3" = 1 -0" 5/8" GYPSUM BOARD OR CMU WALL 3 -5/8" METAL STUDS SEALANT BOTH SIDES HM OR STEEL DOOR FRAME 5/8" GYPSUM BOARD OR CMU WALL 3 -5/8" METAL STUDS *VERIFY THICKNESS OF WALL SEALANT BOTH SIDES JAMB DETAIL - TYPICAL 3 1: _ V-019 GROUP 2A: 1 1/2 — PAIR —BUTTS HAGAR 1129 4 1l2" X 4 1/2" USP 1 — PASSAGE SCHLAGE A10S —LEV -6266 1 — STOP 3 — SILENCER 1 — CLOSER YALE 4020, PAINTED GROUP 3: 1 1/2 — PAIR —BUTTS 1 — LOCKSET SCHLAGE A10S —LEV -626 1 — STOP 1 — CLOSER YALE 4020, PAINTED 3 — SILENCER GROUP 5: BY MANUFACTURER 10. KEYNOTES. 1. 6' X 7' EUASON HIGH IMPACT DOUBLE SWING DOOR (MODEL LWP -3 EASY SWING) EUASON CORPORATION 1- 800 -828 -3655 (SUPPLIED BY FDS, INSTALLED BY CONTRACTOR) 2. THIS DOOR TO HAVE KEYED DEADBOLT. PROVIDE LOCK GUARD DOOR UNDERCUT 1' . 3. 3' -0' X 7' -0' EXIST DOOR, INSTALL ARM A DOOR RPA (W) SECURITY BAR AND ALARM, (SUPPLIED BY FDS). DOOR CLOSER AND PEMKO WEATHERSTRIPPING J 303ASW /S3 INSTALL SIGN ON DOOR ' EMERGENCY EXIT ONLY'. PROVIDE DOOR SWEEP. NO EXTERIOR KNOBS OR HANDLES. CONTACT POSTIVE LOCK ® 1 -800 -342 -7670 4. INSTALL SIGN OVER DOOR: 'THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED' 5. PROVIDE NEW DOOR CLOSERS WITH KAWNEER 'HUSKY II' W. 105 DEGREE HOLD OPEN 6. REPLACE ALL CRACKED AND BROKEN GLASS WITH GLASS OF EQUAL SPECIFICATION OR TEMPERED. AS REQUIRED BY CODE 7. CLEAN AND REPLACE AS NECESSARY ALL INTERIOR AND EXTERIOR STOREFRONT ALUMINUM AND GLASS FOR UNIFORM APPEARANCE. REMOVE ALL TAPE, DECALS, AND OTHER ITEMS ATTACHED TO THE GLASS OR MULLIONS. 8. 4' -0' X 7' -0' NEW DOOR, INSTALL ARM A DOOR #A1OX —XXX (W) SECURITY BAR AND ALARM, (SUPPLIED BY FDS). DOOR CLOSER AND PEMKO WEATHERSTRIPPING # 303ASW /S3 PROVIDE DOOR SWEEP. NO EXTERIOR KNOBS OR HANDLES. CONTACT POSTIVE LOCK ® 1- 800 - 342 -7670 9. PROVIDE 180 DEGREE PEEP —SITE 0 5' -0' A.F.F. IN RECEIVING ROOM DOOR. 10. NOT USED: 3' -0" X 7' -0' NEW DOOR, INSTALL POSITIVE LOCK #THPA (W) SECURITY BAR AND ALARM, (SUPPLIED BY FDS). DOOR CLOSER AND PEMKO WEATHERSTRIPPING # 303ASW /83 INSTALL SIGN ON DOOR ' EMERGENCY EXIT ONLY'. NO EXTERIOR KNOBS OR HANDLES. 11. NOT USED: PROVIDE ONE WAY 12 W X 18 H LAMINATED GLASS WINDOW AT 4' -9' A.F.F IN DOOR. 12. PROVIDE CRASH BARS ON INTERIOR AND EXTERIOR OF NEW DOORS SUSP = 1' -0 an CLOSETS 54' ew 1/8" METAL STUD BRACE ENDS & APPROX. 8' -0' O.C. 'ACH TO TOP TRACK OF WALL 3 5/8' METAL STUDS AT 16" O.C. 5/8" GYP. BD. EACH SIDE uv O Q z U � z Q �z ` I �M ES I DO NOT FASTEN SHEATHING TO TRACK I Z EX. ROOF DECK 2x2x16 go. L 5/8' TYPE 'X' GYP. BD. EA. SIDE 1 1/2' 16GA U CHANNEL BRIDGING (2) St TO EA (S II�ED OPNG. W/ 1 1/20 1/2x16 GA CUP ANGLE W/ (2) SCREWS TO EA STUD METAL STUDS WALL BRACE WALL BRACE 1 1/2 = 1' -0" 131 1 1/2" = 1' -0" FK CUM _ - PMM GYPSUM WMiD - SEE FM 30111M • �� WALL SURFACE 0 32 Ok 4' -0' 11MM. &W -SEE FM SCHFDI!<E 20'-0" STANDARD FINISH ELEVATION 1 /8' = 1' -0' AMERICAN STANDARD, 0321.026.20, WHITE OR EQ. AMERICAN STANDARD, 2096.016.20 WHITE OR EQ. NOTE: PLUMBING FIXTURES & ACCESSORIES TO COMPLY WITH ANSI 117.1 1998 PRO" STOP M CaNTRDI. SMIG DMlECM & MANUFACTURERS' sfinew WEI►1HERST�PPINc KAUM 0 190' NAM N ST1fLE DR JAM B SCALE: 1 1/2" = 1' -0" o�_ L 1 Vii: � �. ���• PROVIDE STOP M CMMML SWIG DMIECM & MMUFACRIFIM STANDARD WANStSTRIPPMIG ( F NOT EXIS1NriG) KAUM 8 190' NARROW S A E � A DOOR OR EQW HE AD SCALE: 1 1/2" = 1' -0" EX WALL PIRM MW DMC N & " STANDARD MMUSIRMM KAWM • 190" NARROW SrAE DWIM AVII011 DOOR OR JAMB 3 SCALE: 1 1/2 = 1' -0" i••.. ... • y .i . . .. IU1W>r>EE t • 190' NARROW SME DWIM =1011 DOOR OR APPROUET) EQUAL ALUMON 1HRES W ANCHOR TO SLAB W M ENPANSION SEW SET M CAULM EACH SIX - 1112• HO MAX - HAHaCNME SILL SCALE: 1 1/2 = 1' -0" General Notes �x No. Revision /Issue I Finn Name and Address MARIDADI 1074 E. 2100 S. SLC, LIT 84106 Project Name and Address FAMILY DOLLAR STORES Ir REXBURG, ID Project Sheet C -10 SCHEDULES Date 1/20/05 Scale 1/8 A4 9 0 sees sun • FME IM MOSTAT • 0(1N6Ilm EtEVAIOR CJW. gunm ! CI181ET5 MWJK ML FME STATION • — ❑ Sw _GlE10014UTA STANDAR MIA" FBAWIE NAPIONS � O Z N .7f�Gl _ �� • zz g 9s o� PLUMBING FIXTURE SCHEDULE FIXTURE SINK TOILET MISC MANUFACTURER *VERIFY THICKNESS OF WALL AL General Notes 4" SOLID CMU OR PRE —CAST CONC. CAP 2 #4 CONT. AT TOP 8' CMU -' �- :►:�: HORIL • :��: 2 ' -6" TRASH ENCLO LIRE WALL 3/4" = 1' —O" 0420M I,)$—not n 1 1/2" RIBBED METAL DECK CMU WALL L2'xrx1 /4 "WITH 1 /2"0 EXP. BOLT AT 24" 0 -T.S. 2 "x2"x1/8" FRAME 2 1/2" x 1118" BAR CONT. WELDED M ALL RAMS -•-•� —C HEAVY am HINGE (3) REauam FOR EACH LEAF" —rs rxa'x3re• GATE SEC110N A • Tr r. r• I L T. A• . L 1 11 1/4 "x1/8" WELDED TO TOP RAIL'" 2 1/2" x 1/8" BAR CONT, WELDED TO ALL RAILS- 1 1/2" ROBED METAL DECK ' lAPIX1 4' CMU CAP L 1 1 /4"xi 1/4 "x1/8" WELDED TO TOP RAIL 2'x3/16' DIAGONAL BRACING 1 1/2' RI88ED METAL DECK T.S. 2"x2"xi/8" FRAME 3/4 "0 x 2' —O" LONG CANE BOLT WITH 90' BEND CMU WALL T.S. 2"x2"x3/16" 11 «� «•� Gw C SLIDE BOLT 3 - 1' -0" TUBE STEEL FRAME SLEEVE FOR 3/8" SLIDE BOLT. WELD M PLATE & FRAME 1/4" PLATE WITH HOLE FOR PADLOCK. WELD TO PLATE GRIND CORNERS 1/2" RADIUS 3'x7"x1/4 "PLATE WELD TO FRAME DETAILS I TRASH 0421=101 No. I Revision /Issue I Date 0 I R cc I BOLLARD Firm Name and Address MARIDADI 1074 E. 2100 S. SLC, UT 84106 Project Name and Address FAMILY DOLLAR .� STORES [rREXBURG, ID Project Sheet C -10 DETAILS °ate 1/20/05 Scale 1/8" =1' -0" 0 0] 6" CONC. SLAB W/ #4 AT 16" O.C. EACH WAY -±-- 8' CMU WALL MATH 4' SOLID CMU CAP ENCLOSURE DOMED CONC. CAP 6" 0 PAINTED STEEL PIPE FILLED SOLID W /CONC. SLOPE TOP PAVING OR GRADE CONC. FOOTING